L Os 1 Smardt T Class WC CHL
L Os 1 Smardt T Class WC CHL
Side and front views of a Smardt T-Class water-cooled chiller customized in a stacked
(narrow) configuration to fit a smaller footprint within a plant room
Turbocor TTS Compressor Multiple Configurations Smardt Restart ensures that in the
T-Class chillers can be equipped Smardt can configure your T-Class chiller event of a power failure, your Smardt
with up to eight Turbocor TTS oil-free to fit any footprint or height restriction, chiller is back on line as quickly as
compressors. VFDs are built-in, and with multiple barrel configurations 20 seconds. Chilled water supply for
drives are internal to the machine. available (see illustration on page 5). critical applications is not impacted by
These oil-free compressors have low- intermittent power loss, eliminating the
sound output and use R134a or R513A Chiller Options need for additional thermal storage. The
refrigerants.* For R513A chiller solutions, Options for Smardt’s T-Class chillers start-up mode includes additional motor
please see Smardt’s G-Class chillers. include our integrated pump packages, and surge protection.
economizer, Smardt Lift, and Smardt
Extended Service Life Restart. Applications
The T-Class chiller is designed for a Energy conscious plant owners and
Smardt Lift enables chiller operation at
service life of 25 years. operators want optimized performance
full load with enhanced efficiencies when
with savings over the life of the chiller.
supplying chilled water at temperatures
Smardt’s T-Class chillers support
that are close to the ambient temperature.
critical-load applications in a variety
This is extremely beneficial in both high
of markets, including commercial, data
temperature chilled water applications or
center, pharmaceutical, hospital, higher
in seasonal operation when the ambient
TTS Compressor education, district cooling, hotels, malls,
temperature is similar to the design
and manufacturing.
chilled water conditions.
Smardt T-Class Water-Cooled Chillers offer barrel configuration flexibility for applications
with restricted footprints or access challenges
Highlights
•Class leading part-load efficiencies,
achieving optimum IPLV in total capacity
range.
Representative Smardt can customize your T-Class chiller to meet your project’s needs and
Models specifications. The models included in this capacity chart are considered
representative of the T-Class, but selection is not limited to to these specific models.
Your Smardt representative can provide capacity data for your project.
WB031.1B
WB044.2H
WE125.3E
WB280.4K
WE320.5K
WB400.6K
WE500.7K
WE600.8K
TR 171 341 512 682 853 1024 1194 1365 1535 1706
kW 0 600 1200 1800 2400 3000 3600 4200 4800 5400 6000
Evaporator Tube
Length Code
Smardt has exercised its best efforts to ensure that the information contained in this document is correct at time of printing. However, no warranty, reliability or accuracy is given with respect to the information contained herein, and Smardt is not and shall not be
responsible for any error or omission, or liable for the correctness or suitability of the information given. All brand names and product names used in this manual are trademarks, registered trademarks, or trade names of their respective holders.
© 2022, Smardt Chiller Group Inc. All rights reserved. 06/2022