0% found this document useful (0 votes)
23 views

Dynex Pump Valve Guide

The document discusses Dynex high pressure pumps and valves that can operate at up to 20,000 psi and in difficult conditions like dirty environments and extreme temperatures. It provides details on checkball pump advantages like contamination tolerance and compatibility with various fluids. It also describes how checkball pumps work and specifications for the PF500 series pumps.

Uploaded by

Murtaza Ali
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

Dynex Pump Valve Guide

The document discusses Dynex high pressure pumps and valves that can operate at up to 20,000 psi and in difficult conditions like dirty environments and extreme temperatures. It provides details on checkball pump advantages like contamination tolerance and compatibility with various fluids. It also describes how checkball pumps work and specifications for the PF500 series pumps.

Uploaded by

Murtaza Ali
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

High Pressure Pumps & Valves

Hydraulic Components
for Extreme Applications

• Up to 20 000 psi (1380 bar)


• Difficult fluids
• Dirty environments
• Extreme temperatures
• Multiple function circuits
Checkball Pump Advantages

The checkball pump design provides extremely reliable operation with little reduction in efficiency
over the life of the pump. When other pumps fail, checkball pumps continue to operate, even at
high pressures, in dirty environments, and with long, difficult duty cycles.

CONTAMINATION COMPATIBILITY WITH


TOLERANT A WIDE RANGE OF
Checkball pumps resist failure due to FLUIDS
contamination, with a large flushing
Checkball pumps provide reliable
path into pistons and through durable
operation with extended life on
outlet check valves.
R & D and production test stands.
Pressure capability to 20 000 psi
(1380 bar) and compatibility with
PRESSURES TO various water-based, phosphate ester
and MIL-SPEC fluids makes these
20 000 PSI (1380 BAR) pumps ideal for testing aerospace
Dynex pumps operate with components.
exceptional reliability at high
pressures. Positive seating check
valves provide better wear and MULTIPLE FLOWS
higher efficiency. This design has
a high horsepower-to-weight FROM ONE PUMP
ratio, to handle higher loads The output from each piston in a
than other pump designs. Dynex pump can be isolated from
the other pistons. This allows one
multiple-outlet pump to replace
BI-DIRECTIONAL up to ten pumps.

ROTATION Flow from each outlet can operate


at different pressures. Piston outputs
Our fixed displacement pumps can be combined to supply different
provide constant flow direction displacements. In circuits requiring
regardless of drive shaft rotation. synchronized movement, flow
accuracy is greater than flow dividers.

HOW THEY WORK


During pump operation, a fixed-angle
wobble plate rotates and imparts a
reciprocating motion to the pistons
in a stationary barrel.
During its suction stroke, each piston
is filled through its inlet check valve.
During compression, the inlet
check valve closes and pressure in
the pumping chamber rises until it
exceeds load pressure. The outlet
checkball then opens and fluid is
pumped out of the chamber.
The outputs from each piston are
combined into either a single
outlet or multiple outlets.

2
PF500 Series Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar) rpm
PF501 0.13 (0,49) 0.16 (0,61) 8000 (560) 3600
PF504 0.21 (0,79) 0.25 (0,95) 8000 (560) 3600
PF507 0.29 (1,10) 0.35 (1,32) 8000 (560) 3600
PF510 0.42 (1,59) 0.51 (1,93) 8000 (560) 3600
PF511 0.17 (0,64) 0.21 (0,79) 8000 (560) 3600
PF500 Series pumps, PF514 0.27 (1,02) 0.33 (1,25) 8000 (560) 3600
with power requirements as low as PF517 0.38 (1,44) 0.46 (1,74) 8000 (560) 3600
0.75 HP (0.6 kW), are used in remote PF520 0.56 (2,12) 0.68 (2,57) 8000 (560) 3600
locations with limited power supply. PF501H 0.12 (0,45) 0.15 (0,57) 15 000 (1040) 3600
These compact pumps operate in PF504H 0.20 (0,76) 0.24 (0,91) 15 000 (1040) 3600
adverse environments at pressures PF507H 0.27 (1,02) 0.33 (1,25) 15 000 (1040) 3600
to 15 000 psi (1040 bar). PF510H 0.42 (1,59) 0.50 (1,89) 15 000 (1040) 3600
One Split-Flow® PF500 pump can PF511H 0.16 (0,61) 0.19 (0,72) 15 000 (1040) 3600
supply independent flows from PF514H 0.27 (1,02) 0.32 (1,21) 15 000 (1040) 3600
up to four separate outlets. PF517H 0.37 (1,40) 0.45 (1,70) 15 000 (1040) 3600
PF520H 0.55 (2,08) 0.66 (2,50) 15 000 (1040) 3600
① Output flow based on typical performance at rated pressure with pressurized inlet where required.
See "Minimum Inlet Pressure" table below and refer to technical literature for complete details.
② Certain operating speeds may require a pressurized inlet.

PF500 Series pumps are used on


portable power packs for high torque
tools where higher speed or more
power is required.
With low input power requirements,
these pumps are used in solar-
powered systems for actuating
valves in remote locations.

Minimum Inlet Pressure①


Operating Speed
1800 rpm 2800 rpm 3600 rpm
Pump
Model psi (bar) psi (bar) psi (bar)
PF501 0 (0) 0 (0) 5 (0,4)
PF504 0 (0) 0 (0) 5 (0,4)
PF507 0 (0) 5 (0,4) 10 (0,7)②
PF510 0 (0) 10 (0,7)② 15 (1,0)②
PF511 0 (0) 0 (0) 5 (0,4)
PF514 0 (0) 0 (0) 5 (0,4)
PF517 0 (0) 5 (0,4) 10 (0,7)②
PF520 0 (0) 10 (0,7)② 15 (1,0)②
① Values shown are based on fluid viscosity of
Checkball pumps operate in some of the most difficult conditions with challenging 100 SUS (20 cSt).
fluids like phosphate ester fire-resistant fluids, or with low viscosity fluids. ② Inlet pressures higher than 10 psi (0,7 bar)
Some models are specially designed for use in low temperature environments. require a high pressure shaft seal.

3
PF1000 Series Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar) rpm
PF1002 1.3 (4,9) 1.5 (5,7) 8000 (560) 3600
PF1003 1.8 (6,8) 2.1 (7,9) 8000 (560) 3600
PF1004 2.2 (8,3) 2.6 (9,8) 8000 (560) 3600
PF1005 2.9 (11,0) 3.5 (13,2) 8000 (560) 2800
PF1006 3.4 (12,9) 4.1 (15,5) 8000 (560) 2800
PF1000 Series pumps PF1002H 1.3 (4,9) 1.5 (5,7) 10 000 (700) 3600
operate with higher volumetric PF1003H 1.8 (6,8) 2.1 (7,9) 10 000 (700) 3600
efficiency than other pump designs. PF1004H 2.2 (8,3) 2.6 (9,8) 10 000 (700) 3600
They provide long life at pressures
PF1005H 2.9 (11,0) 3.5 (13,2) 10 000 (700) 2800
to 10 000 psi (700 bar).
PF1006H 3.4 (12,9) 4.1 (15,5) 10 000 (700) 2800
One Split-Flow® PF1000 pump ① Output flow based on typical performance at rated pressure with pressurized inlet where required.
can supply independent flows See "Minimum Inlet Pressure" table below and refer to technical literature for complete details.
from up to four separate outlets. ② Certain operating speeds may require a pressurized inlet.

Minimum Inlet Pressure①


Operating Speed
2200 rpm 2800 rpm 3600 rpm
Pump
Model psi (bar) psi (bar) psi (bar)
PF1002 0 (0) 0 (0) 5 (0,4)
PF1003 0 (0) 5 (0,4) 10 (0,7)②
PF1004 0 (0) 5 (0,4) 10 (0,7)②
PF1005 5 (0,4) 10 (0,7)② –
PF1006 5 (0,4) 10 (0,7)② –
① Values shown are based on fluid viscosity of
100 SUS (20 cSt).
② Inlet pressures higher than 10 psi (0,7 bar)
require a high pressure shaft seal.

Transfer tables in marine shipyards use Split-Flow® pumps to supply consistent flow
for synchronized lifting. High pressure multiple-outlet pumps used for lifting and
skidding of heavy loads provide greater accuracy with lower cost than flow dividers.

4
PF1300 Series Water Glycol Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar) rpm
PF1301 0.26 (0,98) 0.32 (1,19) 8000 (560) 1800
PF1303 0.36 (1,35) 0.43 (1,63) 8000 (560) 1800
PF1305 0.46 (1,73) 0.55 (2,08) 8000 (560) 1800
PF1308 0.61 (2,29) 0.73 (2,76) 8000 (560) 1800
PF1311 0.43 (1,64) 0.53 (1,99) 8000 (560) 1800
PF1300 Series Pumps PF1313 0.60 (2,25) 0.72 (2,72) 8000 (560) 1800
are compatible with water glycol as PF1315 0.76 (2,87) 0.92 (3,47) 8000 (560) 1800
well as a variety of water-based and PF1318 1.01 (3,82) 1.22 (4,60) 8000 (560) 1800
other low-lubricity fluids. They can PF1320 1.18 (4,46) 1.42 (5,37) 8000 (560) 1800
operate at pressures to 15 000 psi PF1301H 0.23 (0,86) 0.28 (1,06) 15 000 (1040) 1800
(1040 bar) on wellhead control PF1303H 0.32 (1,22) 0.39 (1,48) 15 000 (1040) 1800
systems around the world. PF1305H 0.44 (1,65) 0.53 (1,99) 12 000 (830) 1800
The Dynex single-fluid design PF1308H 0.60 (2,27) 0.72 (2,73) 9000 (630) 1800
eliminates the need for a separate PF1311H 0.38 (1,44) 0.46 (1,76) 15 000 (1040) 1800
lubrication circuit resulting in less PF1313H 0.54 (2,03) 0.65 (2,48) 15 000 (1040) 1800
space, labor, piping, and lower PF1315H 0.72 (2,74) 0.88 (3,32) 12 000 (830) 1800
ongoing maintenance cost. PF1318H 1.00 (3,78) 1.21 (4,56) 9000 (630) 1800
These pumps use the pumped fluid ① Output flow based on typical performance using 33 SUS (1,9 cSt) water glycol fluid at maximum pressure
with flooded inlet. See "Minimum Inlet Pressure" table below.
to lubricate their internal bearings.
② Certain operating speeds may require a pressurized inlet.
This design prevents cross-fluid
contamination, which can occur in
other designs requiring a secondary
oil for lubrication.
Dynex single-fluid water glycol pumps
The checkball design provides a high
provide reliable, low-cost operation,
horsepower-to-weight ratio in a very
with reduced maintenance on wellhead
compact form.
control systems both on- and offshore
around the world.

Minimum Inlet Pressure①②


Operating Speed
1200 rpm 1500 rpm 1800 rpm
Pump
Model psi (bar) psi (bar) psi (bar)
All PF1300 0 (0) 0 (0) 0 (0)
Models
① Values shown are based on fluid viscosity of
33 SUS (1,9 cSt) and related to 1 atmosphere
(29.92" Hg). Pumps using water-based fluids
require a flooded inlet.
② Inlet pressures higher than 10 (0,7 bar)
require a high pressure shaft seal.

Dynex pumps are chosen for critical applications that suppport the production of
oil & natural gas.

5
PF2000 Series Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar) rpm
PF2005 2.5 (9,5) 3.0 (11,4) 8000 (560) 3600
PF2007 3.3 (12,5) 4.1 (15,5) 8000 (560) 2800
PF2008 4.9 (18,5) 5.9 (22,3) 6000 (420) 2400
PF2009 5.1 (19,3) 6.1 (23,1) 4000 (280) 2800
PF2012 7.1 (26,9) 8.5 (32,2) 4000 (280) 2400
PF2000 Series Pumps PF2005H 2.5 (9,5) 3.0 (11,4) 10 000 (700) 3600
are used in high pressure applications PF2007H 3.3 (12,5) 4.1 (15,5) 10 000 (700) 2800
for extreme conditions including dirt,
① Output flow based on typical performance at rated pressure with pressurized inlet where required.
high temperatures, and long, difficult See "Minimum Inlet Pressure" table below and refer to technical literature for complete details.
duty cycles. These pumps operate ② Certain operating speeds may require a pressurized inlet.
reliably at pressures to 10 000 psi
(700 bar).
One Split-Flow® PF2000 pump can
supply independent flows from up
to six separate outlets.
Minimum Inlet Pressure①②
Operating Speed
Pump 2000 rpm 2400 rpm 2800 rpm
Model psi (bar) psi (bar) psi (bar)
PF2005 0 (0) 3 (0,2) 5 (0,4)
PF2007 0 (0) 3 (0,2) 5 (0,4)
PF2008 0 (0) 5 (0,4) –
PF2009 0 (0) 3 (0,2) 5 (0,4)
PF2012 0 (0) 5 (0,4) –
① Values shown are based on fluid viscosity of
100 SUS (20 cSt).
② Inlet pressures higher than 10 psi (0,7 bar)
require a high pressure shaft seal.

Dynex PF2000 Series pumps are used for rock crusher control systems
operating in adverse conditions prone to contaminated fluid.

Up to six independent outlets can be provided from


a single PF2000 checkball pump. The pictured system
was used for lifting large structures with uneven loads.
A high pressure VH Series valve controls the maximum
system pressure for each outlet on this multi-point lifting
sytem. The entire system was designed and built by Dynex.

6
PF3000 Series Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar) rpm
PF3011 6.8 (25,7) 8.1 (30,7) 8000 (560) 2800
PF3015 8.3 (31,4) 10.0 (37,9) 8000 (560) 2500
PF3017 10.0 (37,9) 12.0 (45,4) 8000 (560) 2200
PF3021 12.0 (45,4) 14.4 (54,5) 6000 (420) 2500
PF3024 14.3 (54,1) 17.2 (65,1) 6000 (420) 2200
PF3000 Series Pumps PF3011H 6.8 (25,7) 8.1 (30,7) 10 000 (700) 2800
provide efficient power operating PF3015H 8.3 (31,4) 10.0 (37,9) 10 000 (700) 2500
at pressures to 10 000 psi (700 bar).
① Output flow based on typical performance at rated pressure with pressurized inlet where required.
These reliable pumps are used in See "Minimum Inlet Pressure" table below and refer to technical literature for complete details.
harsh, dirty environments around ② Certain operating speeds may require a pressurized inlet.
the world without concern for
hydraulic failure.
One Split-Flow® PF3000 pump can Minimum Inlet Pressure①
supply independent flows from up
to eight separate outlets. Operating Speed

Pump 1500 rpm 1800 rpm 2200 rpm 2500 rpm 2800 rpm
Model psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
PF3011 0 (0) 0 (0) 5 (0,4) 7 (0,5) 10 (0,7)②
PF3015 0 (0) 3 (0,2) 7 (0,5) 10 (0,7)② –
PF3017 0 (0) 5 (0,4) 10 (0,7) – –
PF3021 0 (0) 3 (0,2) 7 (0,5) 10 (0,7)② –
PF3024 0 (0) 5 (0,4) 10 (0,7) – –
① Values shown are based on fluid viscosity of 100 SUS (20 cSt).
② Inlet pressures higher than 10 psi (0,7 bar) require a high pressure shaft seal.

Dynex compoments are valued for their durability and


contamination tolerence. They are used on various
applications including high pressure bearing lift
systems for power generation turbines.

PF3000 Series pumps with four outlets Split-Flow® pumps used for heavy lifting with strand jacks eliminate the need
operate at high pressure on lubrication for cranes. In this application, PF3000 Series pumps with eight outlet ports
systems. These Split-Flow® pumps simplify replace flow dividers, providing increased output flow accuracy and consistent
the circuit with less components and piping. synchronized movement.

7
PF4000, PF4200 Series Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar) rpm
PF4000 Series Pumps:
PF4011 6.4 (24,2) 7.7 (29,1) 8000 (560) 2400
PF4016 9.3 (35,2) 11.1 (42,0) 8000 (560) 2400
PF4018 10.3 (39,0) 12.4 (46,9) 8000 (560) 2400
PF4020 11.7 (44,3) 14.0 (53,0) 8000 (560) 2400
PF4000 Series Pumps PF4011H 6.1 (23,1) 7.3 (27,6) 10 000 (700) 2400
operate reliably at pressures to PF4016H 8.8 (33,3) 10.5 (39,7) 10 000 (700) 2400
10 000 psi (700 bar). In this design, PF4018H 10.1 (38,2) 12.1 (45,8) 10 000 (700) 2400
the pistons ride on a rotating thrust- PF4020H 11.4 (43,2) 13.7 (51,9) 10 000 (700) 2400
bearing plate for reduced internal PF4200 Series Pumps:
loading and long life operation. PF4203 1.8 (6,8) 2.2 (8,3) 8000 (560) 1800
One Split-Flow® PF4000 pump can PF4205 3.0 (11,4) 3.6 (13,6) 8000 (560) 1800
supply independent flows from up PF4208 4.3 (16,3) 5.2 (19,7) 8000 (560) 1800
to ten separate outlets. PF4209 4.9 (18,5) 5.9 (22,3) 8000 (560) 1800
PF4210 5.6 (21,2) 6.7 (25,4) 8000 (560) 1800
PF4203H 1.6 (6,1) 1.9 (7,2) 20 000 (1380) 1800
PF4205H 2.7 (10,2) 3.2 (12,1) 20 000 (1380) 1800
PF4208H 4.1 (15,5) 4.9 (18,5) 17 000 (1170) 1800
PF4209H 4.7 (17,8) 5.6 (21,2) 17 000 (1170) 1800
PF4210H 5.4 (20,4) 6.5 (24,6) 15 000 (1040) 1800
① Output flow based on typical performance at rated pressure with pressurized inlet where required.
See "Minimum Inlet Pressure" table below and refer to technical literature for complete details.
② Certain operating speeds may require a pressurized inlet.

Minimum Inlet Pressure①


Operating Speed
PF4200 Series Pumps Pump 1500 rpm 1800 rpm 2400 rpm
are capable of pressures to 20 000 psi Model psi (bar) psi (bar) psi (bar)
(1380 bar). These pumps provide long
PF4011 0 (0) 0 (0) 5 (0,4)
life in conditions of severe heat and
PF4016 0 (0) 0 (0) 5 (0,4)
contamination, where dust and dirt
cannot be totally removed by filtration. PF4018 0 (0) 5 (0,4) 10 (0,7)②
PF4020 5 (0,4) 10 (0,7)② 15 (1,0)②
They operate reliably with low
PF4203 0 (0) 0 (0) –
lubricity, low viscosity fluids, including
PF4205 0 (0) 0 (0) –
diesel calibration fluid, Skydrol and
other phosphate ester fluids, and PF4208 0 (0) 5 (0,4) –
other fire-resistant fluids. PF4209 5 (0,4) 10 (0,7) –
PF4210 5 (0,4) 10 (0,7) –
① Values shown are based on fluid viscosity
of 100 SUS (20 cSt).
② Inlet pressures higher than 10 psi (0,7 bar)
require a high pressure shaft seal.

High pressure PF4200 Series motor-pump sets used in steel mills supply the
lubrication systems on finishing stands. These pumps can withstand severe heat
and are more resistant to contamination failure than other pump designs which
are larger and more costly.
Dynex pumps operate with exceptional performance in test stand applications.
High pressure capability with a wide range of fluids provides longer service life
than other pump designs.

8
PF4300 Series Water Glycol Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar) rpm
PF4303 1.8 (6,8) 2.2 (8,3) 8000 (560) 1800
PF4304 2.7 (10,2) 3.2 (12,1) 8000 (560) 1800
PF4305 3.1 (11,7) 3.7 (14,0) 8000 (560) 1800
PF4306 3.8 (14,4) 4.6 (17,4) 8000 (560) 1800
PF4308 4.5 (17,0) 5.4 (20,4) 8000 (560) 1800
PF4309 5.0 (18,9) 6.0 (22,7) 8000 (560) 1800
PF4310 5.7 (21,6) 6.8 (25,7) 8000 (560) 1800
PF4300 Series Pumps PF4312 6.8 (25,7) 8.2 (31,0) 8000 (560) 1800
are compatible with water glycol as PF4303H 1.7 (6,4) 2.0 (7,6) 15 000 (1040) 1800
well as a variety of water-based and PF4304H 2.6 (9,8) 3.1 (11,7) 12 000 (830) 1800
other low lubricity fluids. They operate PF4305H 3.0 (11,4) 3.6 (13,6) 10 000 (700) 1800
at pressures to 10 000 psi (700 bar) PF4306H 3.7 (14,0) 4.4 (16,7) 10 000 (700) 1800
and are frequently used on wellhead PF4308H 4.4 (16,7) 5.3 (20,1) 10 000 (700) 1800
control systems around the world. PF4309H 4.9 (18,5) 5.9 (22,3) 10 000 (700) 1800
The exterior of this series of PF4310H 5.6 (21,2) 6.7 (25,4) 10 000 (700) 1800
pumps is made of stainless steel. PF4312H 6.8 (25,7) 8.1 (30,7) 10 000 (700) 1800

The Dynex single-fluid design ① Output flow based on typical performance using 33 SUS (1,9 cSt) water glycol fluid at maximum pressure
with flooded inlet. See "Minimum Inlet Pressure" table below.
eliminates the need for a separate ② Certain operating speeds may require a pressurized inlet.
lubrication circuit, resulting in less
space, labor, piping, and lower
ongoing maintenance cost.
These pumps use water glycol to
lubricate their internal bearings.
This design prevents cross-fluid
contamination, which can occur in
other designs requiring a secondary
oil for lubrication.
The checkball design provides a
high horsepower-to-weight ratio
in a very compact form.

Minimum Inlet Pressure①②


IMPORTANT: Pumps may require pressurized inlet conditions at higher speeds. Dynex water glycol pumps provide
Failure to meet minimum inlet requirements will result in flow reduction. reliable, low-cost operation, with
Refer to the table. reduced maintenance on deep
water wellhead control systems
Operating Speed
around the world.
1500 rpm 1800 rpm
Pump Model psi bar psi bar
PF4303, PF4305, PF4306 0 0 0 0
PF4304, PF4308 0 0 5 (.5) 0,4 (0,03)
PF4309 5 (0) 0,4 (0) 10 (1) 0,7 (0,07)
PF4310, PF4312 5 (0) 0,4 (0) 15 (2) 1,0 (0,14)
① Values shown are based on fluid viscosity of 33 SUS (1,9 cSt) and related to 1 atmosphere (29.92” Hg).
② Values in parentheses are for “Q” option.

9
PF6000 Series Pumps

Specifications
Output Flow Output Flow Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Speed②
Model gpm (L/min) gpm (L/min) psi (bar) rpm
PF6020 11.8 (44,5) 14.1 (53,4) 15 000 (1040) 1800
PF6024 13.8 (52,3) 16.6 (62,8) 15 000 (1040) 1800
PF6030 18.0 (68,2) 21.6 (81,8) 15 000 (1040) 1800
PF6033 19.1 (72,3) 22.9 (86,7) 10 000 (700) 1800
PF6042 24.8 (94,0) 29.8 (112,8) 10 000 (700) 1800
PF6000 Series Pumps PF6046 26.1 (98,8) 31.3 (118,5) 8000 (560) 1800
provide high flow operating at PF6054 29.5 (111,7) 35.2 (133,2) 6000 (420) 2400
pressures to 15 000 psi (1040 bar). PF6070 39.7 (150,3) 48.3 (182,8) 6000 (420) 2300
They are ideal for extreme conditions
① Output flow based on typical performance at rated pressure with pressurized inlet where required.
including dirty environments, extreme See "Minimum Inlet Pressure" table below and refer to technical literature for complete details.
temperatures, and long, difficult ② Certain operating speeds may require a pressurized inlet.
duty cycles.
One Split-Flow® PF6000 pump can
supply independent flows from up
to ten separate outlets.
Minimum Inlet Pressure①
Operating Speed
1500 rpm 1800 rpm 2400 rpm
Pump
Model psi (bar) psi (bar) psi (bar)
PF6020 5 (0,4) 5 (0,4) –
PF6024 5 (0,4) 5 (0,4) –
PF6030 5 (0,4) 10 (0,7) –
PF6033 5 (0,4) 10 (0,7) –
PF6042 5 (0,4) 15 (1,0) –
PF6046 5 (0,4) 10 (0,7) –
PF6054 5 (0,4) 5 (0,4) 10 (0,7)
PF6070 5 (0,4) 10 (0,7) 10 (0,7)
① Values shown are based on fluid viscosity of 100
SUS (20 cSt). All PF6000 Series pumps have
high pressure shaft seals.

Dynex pumps are used on test stands


where reliable performance in harsh
test conditions is critical. These test
stands are used in various aerospace
applications, both commercial and
military.

Dynex high pressure pumps have


been used on industrial presses since
1960. Some pumps, operating at
pressures to 15 000 psi (1040 bar),
have been in use for 60 000 hours
without failure.

10
PV4000, PV6000 Series Variable Delivery

Specifications
Output Flow Output Flow Rated Maximum Maximum
Pump at 1500 rpm① at 1800 rpm① Pressure Pressure Speed②
Model gpm (L/min) gpm (L/min) psi (bar) psi (bar) rpm
PV4000 Series Pumps (Mechanical Variable Delivery with optional Pressure Compensation):①
PV4011 6.1 (23,1) 7.3 (27,6) 6000 (420) 8000 (560) 1800
PV4016 8.9 (33,7) 10.7 (40,5) 6000 (420) 8000 (560) 1800
PV4018 10.0 (37,9) 12.0 (45,4) 6000 (420) 8000 (560) 1800
PV4020 11.4 (43,2) 13.7 (51,9) 6000 (420) 8000 (560) 1800
PV4000 Series Pumps PV4026 14.6 (55,3) 17.5 (66,2) 4000 (280) 6000 (420) 1800
supply infinitely variable flow PV4033 18.7 (70,8) 22.4 (84,8) 4000 (280) 6000 (420) 1800
controlled by the linear movement PV4011H 5.8 (22,0) 7.0 (26,5) 8000 (560) 10 000 (700) 1800
of a volume stem control.
PV4016H 8.6 (32,6) 10.3 (39,0) 8000 (560) 10 000 (700) 1800
PV4018H 9.7 (36,7) 11.6 (43,9) 8000 (560) 10 000 (700) 1800
PV4020H 11.0 (41,6) 13.2 (50,0) 8000 (560) 10 000 (700) 1800
PV6000 Series Pumps (Hydraulic Variable Delivery):
PV6054 29.3 (110,9) 35.1 (132,9) 6000 (420) 6000 (420) 2400
PV6070 38.7 (146,5) 46.4 (175,6) 6000 (420) 6000 (420) 2300
① Output flow based on typical performance at rated pressure with pressurized inlet where required.
See "Minimum Inlet Pressure" table below and refer to technical literature for complete details.
② Certain operating speeds may require a pressurized inlet.

Minimum Inlet Pressure①


PV6000 Series Pumps
are rugged pumps designed to Operating Speed
handle high loads and extreme Pump 1500 rpm 1800 rpm 2400 rpm
operating conditions. Model psi (bar) psi (bar) psi (bar)
Models with an integral pressure PV4000 Series Pumps (Mechanical Variable):
compensator efficiently override PV4011 0 (0) 0 (0) –
the volume control to smoothly and PV4016 0 (0) 0 (0) –
quietly regulate delivery at a preset PV4018 0 (0) 5 (0,4) –
pressure up to 6000 psi (420 bar). PV4020 0 (0) 5 (0,4) –
On hydraulic variable delivery pumps, PV4026 5 (0,4) 5 (0,4) –
output is regulated by an external PV4033 5 (0,4) 5 (0,4) –
low-pressure control signal supplied PV6000 Series Pumps (Hydraulic Variable):
to a control port in the cover. PV6054 5 (0,4) 5 (0,4) 10 (0,7)
One Split-Flow® PV6000 pump can PV6070 5 (0,4) 10 (0,7) 10 (0,7)
supply two variable flows, or one fixed ① Values shown are based on fluid viscosity of
100 SUS (20 cSt).
and one variable flow. Each output is
independently controlled. Variable delivery PV6000 Series
pumps used on drill rigs power the
drill rotation, drill pressure, mast
movement, and propulsion.
They've proven to be rugged and
reliable even when subjected to
shock, vibration, and long duty cycles.
Dynex variable delivery pumps
provide long service life on test stands
for the challenging requirements of
aerospace testing.

11
High Pressure Directional Control Valves

Specifications
Nominal Flow Maximum Flow Maximum Pressure
Valve Model U.S. gpm (L/min) U.S. gpm (L/min) psi (bar)
HP03 5.0 (19) 15.0 (57) 10 000 (700)
HP05H 30.0 (114) 40.0 (151) 8500 (586)

HP03 Directional Control Valves


operate at pressures to 10 000 psi
(700 bar), double that of most other
conventional subplate mounted
spool valves.
Actuator options include:
Manual Lever, Direct Solenoid,
Hydraulic Piloted, and Air Piloted.

With some of the highest pressure ratings available, Dynex valves have been used
for decades in many industrial applications like presses.

HP05H Directional Control Valves


provide high pressure, high flow
capability. The valve’s low pressure
drop is enhanced with the use of
the Dynex standard subplate, which
takes advantage of the valve’s special
double tank port design.
Actuator options include:
Solenoid piloted, Hydraulic Piloted,
and Air Piloted.

12
Pressure Control Valves

Specifications
Maximum Flow Maximum Pressure
Valve Model Function U.S. gpm (L/min) psi (bar)
H8819-5015 Relief 50 (190) 15 000 (1040)
H8819-7509 Relief 75 (284) 9000 (620)
VHR Relief 30 (114) 15 000 (1040)
VHU Unloading 30 (114) 7000 (490)
VHD Decompression 30 (114) 15 000 (1040)
VP Remote Proportional Relief 1 (3,7) 15 000 (1040)

H8819 Series High pressure/


High-Flow Relief Valves are available
in Manual, Electrohydraulic
Proportional Control, or Electric
Vent Option.
They are compatible with conventional
fluids and special fluids, including
low viscosity, MIL-SPEC, and other
phosphate ester fluids (Skydrol, etc.).

VH Series High pressure Control


Valves are available in Manual,
Electrohydraulic Proportional
Control, or Electric Vent Option.
They are compatible with conventional
fluids and special fluids, including low
viscosity, MIL-SPEC, and other phosphate
ester fluids (Skydrol, etc.).

This product can be used for relief,


unloading, and decompression
applications.

VP Series Remote Proportional


Relief Valves are used in high-pressure
systems. These poppet-style valves
operate with fast response to system
conditions.
They provide reliable pressure
regulation and circuit protection at
pressures to 15 000 psi (1040 bar).

13
High Pressure Valve Accessories

Sandwich Valve Specifications


Nominal Flow Maximum Flow Rated Pressure
Valve Model (Size) Function U.S. gpm (L/min) U.S. gpm (L/min) psi (bar)
VSWCH (HP03) Pilot Operated Check 5.0 (19) 8 (30) 10 000 (700)
VSWRL (HP03) Relief 5.0 (19) 10 (38) 10 000 (700)

VSW-HP03 Pattern Sandwich


Valves are designed to work with
our HP03 Directional Control Valves.
The functions include pilot-operated
check and pressure relief.

Subplate Specifications
Valve Mounting Maximum Flow Rated Pressure
Valve Model (Size) Pattern Function U.S. gpm (L/min) psi (bar)
SPRV-D03-SAE8 D03 Relief 15 (57) 5000 (350)
SPRV-HP03-.56MP HP03 Relief 15 (57) 10 000 (700)
SPRV-D05-SAE8 D05 Relief 40 (151) 5000 (350)
SPRV-D05H-SAE12 D05H Relief 40 (151) 5000 (350)
SPRV-D08-SAE16 D08 Relief 90 (341) 5000 (350)
SPRV Pattern Subplates have an
integral relief valve and are for use
with our Directional Control Valves.

High Pressure Parallel Manifold Specifications


Maximum Pressure
Valve Mounting Pattern Number of Stations psi (bar)
HP03 2 10 000 (700)

MSO-HP03 Parallel Manifolds


provide multiple HP03 valve stations
to help reduce high-pressure
plumbing and reduce the overall
layout of a hydraulic circuit.
As a standard option, Dynex offers
a two-station manifold, but other
options are possible.

14
Power Units & Systems

Designed with quick turn-around in mind, these units incorporate the


most commonly used features in a compact package with a small footprint.
Our QuickPacks really stand out for having some of the highest
pressure ratings in the industry up to 10 000 psi (700 bar).

QuickPack 5 Specifications
Series Reservior Capacity Power Source Maximum Pressure Flow Range
Electric Up to 10 000 psi 0.21 to 0.68 gpm
QuickPack 5 5 gallons (25,6 liters) (Single-phase or (700 bar) (0,79 to 2,57 L/min)
3-phase) at 1800 rpm

QuickPack 25 Specifications
Series Reservior Capacity Power Source Maximum Pressure Flow Range

Electric Up to 10 000 psi 1.5 to 5.9 gpm


QuickPack 25 25 gallons (94,6 liters) (3-phase) (700 bar) (5,7 to 22,3 L/min)
at 1800 rpm

15
USA Headquarters Power Units & Systems
770 Capitol Drive 54 Nickerson Road
Pewaukee, WI 53072 Ashland, MA 01721
Tel: +1 (262) 691-0300 Tel: +1 (508) 881-5110
Fax: +1 (262) 691-0312 [email protected]
[email protected]

European Sales Middle East Sales


Unit C5 Steel Close, Little End Road, JAFZA 1, Tower A, 11th Floor
Eaton Socon, St Neots, Jebel Ali Freezone
Cambs. PE19 8TT United Kingdom Dubai, UAE
Tel: +44 (0) 1480 213980 Tel: +971 547422353
Fax: +44 (0) 01480 405662 [email protected]
[email protected]

Specifications shown were in effect when published.


Since errors or omissions are possible, contact your Dynex
Sales representative or the Dynex Sales department
for the most current specifications before ordering.
Dynex reserves the right to discontinue products or
change designs at any time without incurring any obligation.

www.dynexhydraulics.com
Copyright © Dynex/Rivett Inc. Printed in U.S.A. Bulletin PVG Jan 2024

You might also like