0% found this document useful (0 votes)
10 views

Appleton灯具

Uploaded by

leo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

Appleton灯具

Uploaded by

leo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 562

LIGHTING

Corrosive elements. Combustible dusts.


Flammable gases and vapors. For proper
illumination in extreme conditions, you
need a company that pushes safety to
the extreme. Appleton has expanded
the boundaries of technology, efficiency
and performance to ensure your lighting
stays on – and safe. Because failure just
isn’t an option.
LIGHTING
Lighting

Lighting
Lighting
Description Page

Enclosed and Gasketed — Area — HID


Mercmaster™ III Luminaires Family Tree 920
Mercmaster™ III Low Profile Luminaires 922
Mercmaster™ III HID 50—250 Watt Luminaires 941
Mercmaster™ III 400 Luminaire for Hazardous
976 MMIII Low Profile MMIII 50-250 MMIII 400
and Wet Locations
ATX LN Series Wellglass Luminaires 995
Mercmaster™ II HID Luminaires 1005
Mercmaster™ Jr. Luminaires 1021

Enclosed and Gasketed — Area — LED/Induction


Mercmaster™ LED Luminaires 1028
Mercmaster™ III Induction Luminaires 1037 LN Series MMII MM Jr.

Enclosed and Gasketed — Area — Fluorescent


Mercmaster™ III Low Profile Compact
1055
Fluorescent Luminaires
FV™ Series Nonmetallic Fluorescent Luminaires 1070
FR™ Enclosed and Gasketed; FZ™ and FD™
1075 MM LED MMIII Induction MMIII Low Profile
Hazardous Locations Luminaires
ATX FE Series Nonmetallic Fluorescent
1081
Luminaires
ATX FL Series Light Duty Nonmetallic
1095
Fluorescent Luminaires
ATX FN Series Heavy Duty Nonmetallic
1100
Fluorescent Luminaires
RigMaster™ Metallic Fluorescent Luminaires 1106 FV Series FR Series

RigMaster™ 304 Stainless Steel Fluorescent


Luminaires
1111
V
VRS™ and DRS™ Fluorescent Luminaires 1113
FL Series FN Series
Enclosed and Gasketed — Area — Recessed Fluorescent
RE Series Recessed Fluorescent Luminaires 1119

RigMaster™ Metallic RigMaster™ 304 Stainless Steel — V

VRS/DRS

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 913


© September 2010
Lighting
Lighting
Lighting

Description Page

Enclosed and Gasketed — Area — Incandescent


Stylmaster™ Incandescent Luminaires 1126
V—51 Incandescent Luminaires
®
1135
REA™ 150 W Incandescent Luminaires 1147
Stylmaster V—51 REA
Enclosed and Gasketed — Floodlight
Areamaster™ 100 Wide—Beam Floodlights 1149
Areamaster™ 250/400 Integrally Ballasted
1155
Floodlights
Areamaster™ 1000 Floodlights 1162

ATX PN Series Floodlights – Zone 2, 21 and 22 1166

Corroflood™ 250/400 Stainless Steel Floodlights 1171 Areamaster 100 Areamaster 250/400 Areamaster 1000
Wallmaster I/2 for Hazardous and Wet Locations
— Class I, Division 2/Zone 2
1174
V

Enclosed and Gasketed — Visual Signal


TVA Obstruction, Approach and Boundary
Luminaires
1176
V
Stylmaster™ Strobe Luminaires 1180
PN Series Corroflood Wallmaster — V
Enclosed and Gasketed — Emergency
Mercmaster™ III Emergency Battery Pack 1184
N2LS™ Series Emergency Luminaires 1200

Explosionproof — Area — HID


Code•Master Jr.™ HID Factory Sealed
1205 TVA — V Stylmaster Strobe MMIII Emergency N2LS
Luminaires
Battery Pack
Code•Master 2™ HID Factory Sealed Luminaires 1216

Explosionproof — Area — Induction


Code•Master 2™ Induction Lighting System 1231

Code•Master Jr Code•Master 2™ Code•Master 2 Induction

914 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lighting

Lighting
Lighting
Description Page

Explosionproof — Area — Fluorescent


Code•Master™ PLT Factory Sealed Luminaires 1240
APL Two and Four Lamp Fluorescent Factory
1252
Sealed Luminaires

EFU Fluorescent Factory Sealed Luminaires 1256

PAPL Portable Two and Four Lamp Fluorescent


1260 Code•Master PLT APL EFU
Factory Sealed Luminaire
ATX FD Series Cylindrical Fluorescent
1262
Luminaires

Explosionproof — Area — Incandescent


Code•Master™ Incandescent Factory Sealed
1269 PAPL FD Series
Luminaires
A—51 Incandescent Factory Sealed Luminaires
®
1274
EDT Incandescent Luminaires 1288

Explosionproof — Floodlight

Code•Master 2™ HID Factory Sealed Floodlights 1289

EFL Series HID and Quartz Floodlights 1297


V Code•Master A-51 EDT

PB, PC & PL Series 1300


Explosionproof Floodlights 1306

Explosionproof — Visual Signal


Code•Master™ Factory Sealed Strobe
1308
Luminaires

Explosionproof — Portable Code•Master 2 EFL/PB/PC/PL Explosionproof


TCH Series Safety Flashlights 1314
AHL and EHL Incandescent Factory Sealed
1316
Luminaires and Handlamps

Code•Master Strobe TCH Series AHL

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 915


© September 2010
Lighting
Lighting
Lighting

Description Page

Explosionproof — Emergency
Code•Master 2™ Emergency PLT Factory
1318
Sealed Luminaires
ELS Series Emergency Lighting System 1327

Increased Safety/Flameproof — Bulkhead


ATX HBE Series Round Bulkhead Luminaires 1133 Code•Master 2 Emergency PLT ELS Series
ATX HBD Series Bulkhead Luminaires 1336
ATX HBN Series Round Bulkhead Luminaires 1341
ATX HBDC Series Cylindrical Bulkhead
1344
Luminaires

General Lighting — Area — High Bay HBE/HBN Series HBD Series HBDC Series
Baymaster 250/400™ High Bay Luminaires 1347
Baymaster Prismatic 250/400™ High Bay
1353
Luminaires
Super-Baymaster High Bay Luminaires 1358
V
Baymaster 1000™ High Bay Luminaires 1361

General Lighting — Area — Low Bay


Lumenmaster 250™ Low Bay HID Prismatic Baymaster Baymaster Super-
1365 Baymaster 1000
Luminaires 250/400 Prismatic 250/400 Baymaster — V
Lumenmaster 400™ Low Bay HID Prismatic
1370
Luminaires

General Lighting — Area — Floodlights


Quartzlite™ 50 Floodlight 1375
Quartzlite™ 500/1500 Floodlight 1376
Areamaster Jr.™ HID Wide-Beam Floodlights 1379 Lumenmaster 250 Lumenmaster 400
Beam-Master™ Floodlights 1383

Quartzlite 50/500 Areamaster Jr Beam-Master

916 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lighting

Lighting
Lighting
Description Page

General Lighting — Area — Architectural


Wallmaster™ HPS/PSMH Luminaires 1386
Wallmaster™ 400 HPS/PSMH Luminaires 1390
Areamaster Squarelite™ 400 Sharp Cutoff
1395
Luminaires
Wallmaster Wallmaster 400 Areamaster Squarelite
General Lighting — Area — Poles and Hangers
Round Tapered Steel Poles 1499
Hinged Steel Poles 1400
Square Tapered Steel Poles 1401
Square Steel Poles 1402
Floodlight Mounting Brackets 1403 UNJ AL

Flexible Fixture Hangers — Ordinary Location


AHG and UNJ Flexible Fixture Hangers 1407
AL Ball and Cushion Flexible Fixture Hangers 1408 Mounting Poles JB SSH
JB and GS Flexible Fixture Hangers 1412
SSH Flexible Fixture Hangers 1414
SHC Flexible Fixture Hangers 1416
Flexible Fixture Hangers — Hook and Loop 1417
Flexible Fixture Hangers — Receptacle and Receptacle and
1420 SHC Hook and Loop Power Hook — V
Hook and Loop Hook and Loop
Power Hook for Industrial High Bay Luminaires 1421
V
Flexible Fixture Hangers — Explosionproof
BKX Rigid Fixture Hangers 1422
V
CPU and EFHU Fixture Hangers 1424 BKX CPU ESD
Flexible Fixture Hangers, EXJF Couplings, ESD
1427
and ESS Swivels
EFHC and EFHCA Fixture Hangers and
1430
Accessories
GRF Conduit Outlet Boxes and Fixture Hanger
1432
Covers and Canopies
EFHC GRF Bracket
Fixture Hanger Bracket and Accessories 1434

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 917


© September 2010
Lighting
Lighting
Lighting

Description Page

McGill Temporary
HID Temporary Lighting 1436
String-O-Lights 1437
7000 Series Industrial Extension Lights 1439
7000-38 Series Industrial Extension Lights 1442
6000 Series Commercial-Duty Extension Lights 1443
5000 Series Industrial Extension Lights 1444 HID Temp String-O-Lights 7000/6000/5000
Industrial Extension Lights 1446 Extension Lights

Handy Compact Fluorescent Work Light 1447


Rough Service Fluorescent Lamp 1448
Fluorescent Work Lights 1449
Battery Pack with Charger 1450
Fluorescent Industrial Extension Lights 1451
High Intensity Low-Voltage Extension Lights 1452
Mini-Powerpak Low-Voltage Extension Lights 1453 Handy Compact Rough Service Fluorescent Work
Fluorescent Hand Lamps — Explosionproof 1454
Tubular Fluorescent Inspection Light —
1455
Explosionproof
Industrial Extension Lights — Explosionproof 1456
Low-Voltage, High Intensity Hand Lamp —
1457
Explosionproof

Battery Pack Industrial Extension High Intensity


Lights

Mini-Powerpak Hand Lamp Tubular Inspection Light

Low-Voltage,
Industrial Extension Lights
High Intensity Hand Lamp

918 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lighting

Lighting
Lighting
Description Page

McGill General
Incandescent Utility Lights 1458
Fluorescent Utility Lights 1460

McGill Lamp Protection


Protect-O-Sleeves 1461 Utility Lights Protect-O-Sleeves Protect-O-Tubes
Protect-O-Tubes 1463
Tubeloc Holders 1464
Protect-O-Globes 1465
Wire Lamp Guards and Wire Lamp Guard
1466
Grounding Kit
Tubeloc Holders Protect-O-Globes Wire Lamp Guard
McGill Lamp Changers
Fluorescent Lamp Changers 1467
Incandescent Lamp Changers 1468
Lamp Changer Accessories and Replacement
1470
Parts
Lamp Changers

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 919


© September 2010
Mercmaster™ III Luminaires Family Tree

Flexible Cone
Pendant Mount Pendant Mount Pendant Mount Ceiling Mount 25° Stan
KPAF75 KPA75 KPCH75 KPC75 K
KPAF100 KPA100 KPCH100 KPC100 K
Lighting

MLBG SERIES MLBR SERIES KPB SERIES


50 W-150 W HPS 50 W-150 W HPS 50 W-150 W HPS
50 W-175 W PSMH 50 W-175 W PSMH 100 W, 175 W,
POLYMERIC
Lighting: Enclosed and Gasketed — Area — HID

Med. Base Med. Base 200 W, 250 W PSMH (KPBG)


REFRACTORS 5.50"/
NEMA 2 LPRF-2CP 26-84 W Fluorescent 7.75"/ 26-84 W Fluorescent Mogul Base
139.7mm 196.9mm 5.50"/
NEMA 3 LPRF-3CP 139.7mm
NEMA 4 LPRF-4CP
NEMA 5 LPRF-5CP
• Fluorescent
• Metal Halide
100W Max. Metal Halide
(Lamp Extender Standard Dome Deep Dome 100W Max
not required) 30° Angle Lamp Extender
CMR-4ST * CMR-4DD *
CMR-4AN

GLASS REFRACTORS Standard Dome


NEMA 1 LPG-R1
CMR-4ST *
Standard Dome Deep Dome NEMA 3 LPG-R3
NEMA 5 LPG-R5
KR2-ST KR2-DD 30° Angle POLYMERIC
KR2-AN REFRACTORS
NEMA 2 LPRF-2CP
NEMA 3 LPRF-3CP
KRG2 NEMA 4 LPRF-4CP
Refractor Guard NEMA 5 LPRF-5CP
HID GLASS GLOBE GLASS GLOBE GLASS GLOBE
Clear VPGL-1HR Fluorescent Clear VPGL-3HR
Clear VPGL-2HR (for 100 W HPS only)
Amber VPGL-1AM
5.63"/ Amber VPGL-2AM
Blue VPGL-1BL 143.0mm
8.00"/
Green VPGL-1GR 203.2mm Blue VPGL-2BL
Red VPGL-1RE Green VPGL-2GR
Red VPGL-2RE

Standard Dome Deep Dome


KGU1 KGU2 30° Angle
KR2-ST KR2-DD
HID 8.50"/ Fluorescent KR2-AN
215.9mm
GlobeGuard Globe Guard
6.75"/171.5mm GLASS GLOBE
KRG2
Clear VPGL-2HR
Amber VPGL-2AM Refractor Guard

EXIT
Blue VPGL-2BL
9.25"/ Green VPGL-2GR
235.0 mm Red VPGL-2RE

Three-Way Exit Sign KGU2


CJEXRN Globe Guard

5.75"/146.1mm 5.69”/
DIA. 144.5mm
* Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
11.38"/
289.1mm
920 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
6.63”/ © September 2010
168.4mm
13.25"/336.6mm
Mercmaster™ III Luminaires Family Tree

ing Mount 25° Stanchion Mount 90° Stanchion Mount Wall Mount
KPC75 KPS125 KPST125 KPWB75
KPC100 KPS150 KPST150 KPWB100

Lighting
KPB SERIES KPBR SERIES KPB400 SERIES
50 W-150 W HPS 50 W-150 W HPS 250 W-400 W HPS
100 W, 175 W, 100 W, 175 W, 250 W, 320 W, PSMH

Lighting: Enclosed and Gasketed — Area — HID


200 W, 250 W PSMH (KPBG) 200 W, 250 W PSMH 350 W, 400 W PSMH
Mogul Base Mogul Base Mogul Base
0"/ 7.75"/
7mm 196.9mm

7.75"/
196.9mm

Metal Halide
100W Max
Lamp Extender Standard Dome
CMR-4ST*

Standard Dome Deep Dome GLASS REFRACTORS


30° Angle
CMR-4ST * CMR-4DD * NEMA 2 KPRF-400-2
CMR-4AN 30° Angle
CMR-4AN NEMA 3 KPRF-400-5
OLYMERIC 16” Lens
FRACTORS Enclosed Reflector
MA 2 LPRF-2CP KPR-4HB
MA 3 LPRF-3CP
MA 4 LPRF-4CP
MA 5 LPRF-5CP
GLASS GLOBE
GLASS GLOBE GLASS REFRACTORS Clear VPGL-4HR
Clear VPGL-3HR NEMA 1 LPG-R1
(for 100 W HPS only) NEMA 3 LPG-R3
NEMA 5 LPG-R5

KPBG-12
12” Wire Guard GHB7000-NG
30° Angle 16” Wire Guard
KR2-AN

GLASS GLOBE
KRG2 KRG2 KPGU400
Clear VPGL-2HR
Amber VPGL-2AM Refractor Guard Refractor Guard Globe Guard
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE

GU2
lobe Guard

* Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 921


© September 2010
Mercmaster™ III Low Profile Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors or combustible
Lighting

dusts are present under conditions defined by the National


Electrical Code as Class I, Division 2; Class II, Division 1 and
2; and Class III
— Areas of low clearance, low ceiling heights or where fixture
weights must be minimized
— For Zone 2, the method of protection is AEx nA nR –
Restricted Breathing/Nonsparking or AEx nR – Restricted
Breathing
Lighting: Enclosed and Gasketed — Area — HID

— Non-hazardous locations where severe weather conditions,


excessive moisture, dirt, dust, corrosive atmosphere or high
Low Profile Mercmaster III with Prismatic Globe and Guard
ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants Standard Materials
— Oil refineries • Mounting hoods, bodies and guard: cast copperfree
— Foundries (4/10 of 1% max.) aluminum
— Manufacturing plants • All hardware and catch assemblies: stainless steel
— Storage areas • Reflectors: Fiberglass reinforced white polyester
— Waste and sewage treatment • Globes and Refractors: heat-resistant prismatic glass
— Parking garages Standard Finishes
— Other areas where dust, water, dirt and rough usage are a
problem • Mounting hoods, bodies and guards: baked gray epoxy-clad
finish, electrostatically applied for complete uniform protection
Features
Options
• Compact light weight low profile design is suited for low
mounting heights in conjunction with lower wattage fixtures. • Quartz Auxiliary comes to full brightness immediately and
• Modular design allows scores of fixture component combinations remains lit until the HID lamp attains 60-70% of full illumination.
to meet installation and lighting needs. Uses same mounting Quartz Auxiliary supplied with relay switch and socket to accept
hoods and optical accessories as Mercmaster III. 120 V quartz double-contact bayonet base lamp (not included).
• A choice of heat-resistant prismatic glass refractors (NEMA I, III Add suffix -E †.
or V) or heat-resistant globes which thread directly into ballast • Guards with gray epoxy painted to match fixtures, supplied with
housing. Photometrics available upon request ­– contact your stainless steel screws. Add suffix -G before voltage suffix.
local sales representative. • Hot Restrike to restrike HPS lamp immediately when power is
• Standard dome or 30° angle reflectors made of fiberglass restored after a momentary power interruption. Add suffix -R.
reinforced white polyester. Highly resistant to corrosive • Smart Starter incorporates a 1-1/2 minute timer and performs
atmospheres. as a conventional starter to normally start lamp. Removes
• Accommodates medium base lamps. itself from circuit if lamp burns out or is removed from socket.
• A wide range of voltages available (120 to 600 Volt) and ballast Eliminates starter failures caused by prolonged operation with
types (Reactor, CWA, CWI and Super CWA). cycling or failing lamps and simplifies finding their location,
• Medium base lamp type and watts: reducing maintenance and repair costs. Available for all fixtures.
— HPS 50 W-150 W Add suffix -S.
— PSMH 50 W-175 W • Smart Hot Restrike will immediately restrike HPS lamp when
• Hinge has high lip for added safety during installation power is restored after a momentary power interruption. The
and servicing. Hinge and bolt construction assures 360º smart function removes the hot restrike ignitor from the circuit
compression at all points on ballast housing gasket for positive if the lamp burns out or is removed from the socket. Eliminates
sealing. Swing away design of captive bolt and nut simplifies starter failures caused by prolonged operation with cycling or
servicing. failing lamps. Add suffix -SR.
• All Mercmaster III mounting hoods have provision for easy field • AEx nA nR fixtures, add suffix -Z2.
installation of fuses in fixtures (see fuse kits). • AEx nR fixtures, add suffix -ZB.
• Fixtures are for use in Class I, Zone 2 hazardous locations. • Ex nR fixtures, add suffix -Z V.
• The AEx nA nR / Ex nR (V) factory sealed Mercmaster III • Reflectors are available as standard dome and 30° angle
prevents vapors and gases from entering the globe chamber. polyester. Order separately.
There are no seals or putty required which will reduce
installation time and installation errors.

† Fixtures equipped with quartz auxiliary lamp do not comply with NEC/CEC V requirements and are not suitable for use in classified locations.
V CSA Certification Only.

922 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Certifications and Compliances * Related Products


• UL Listed: 60079-15 • Photocells for classified use are available, see PCD2 Series.
• UL Standard: 1598A, UL 844, Marine Type Electric Fixtures
Outside Type (Salt Water)
• CSA Certified: LR25428

Lighting
Order using catalog numbering guide below or select catalog number from tables on following pages.

Catalog Numbering Guide


ML A L 15 2 G1 G MT R Z2

Lighting: Enclosed and Gasketed — Area — HID


Series: Lamp Type: Hub Size: Guard Options: Options:
ML - I - Incandescent 2 - 3/4” NPT G - Cast Guard E - Emergency Quartz ➎
Mercmaster III L - High Pressure 3 - 1” NPT N - No Guard F - Fuse Kit (Specify
Low Profile Sodium 4 - 1-1/4” NPT Voltage) ➏
H or P - Pulse Start stanchion R - Hot Restrike ➌
Metal Halide 5 - 1-1/2” NPT S - Smart Starter ➍
H - 175 W Metal stanchion SR - Smart Hot
Halide (available Restrike ➌
with TT voltage H1 - Photocontrol 120 V
only) V H2 - Photocontrol 208 V
H3 - Photocontrol 240 V
H4 - Photocontrol 277 V
C - Safety Cable
Adapted V
D - E-27 Export Socket
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➐
Mounting Hood
Adapter V
Mounting: Wattage: Optical Assembly: ➋ Voltage: ➊ Suffix:
A - Pendant (rigid 10 - 100 W HPS, PSMH G1 - Globe LB - Incandescent, 120, Z2 - Zone 2 suffix
mounting) 15 - 150 W HPS, PSMH J1 - NEMA I Glass 60 Hz (required for
C - Ceiling and 60-150 W max. Refractor MT - 120/208/240/277, AEx nA nR
D - Pendant Cone Hood Incandescent 60 Hz rating)
J3 - NEMA III Glass 5MT - 120/208/240/
F - Pendant (flexible 17 - 175 W PSMH Refractor 277/480, 60 Hz ZB - Zone 2 suffix
mounting) 17 - 175 W MH V J5 - NEMA V Glass 48 - 480, 60 Hz (required for
R - 90° Stanchion 50 - 50 W HPS, PSMH Refractor 125 - 120, 50 Hz AEx nR)
S - 25° Stanchion 70 - 70 W HPS, PSMH P2 - NEMA II Polymeric 225 - 225, 50 Hz Z - Zone 2 suffix
W - Wall Refractor 226 - 220, 60 Hz (required for
P3 - NEMA III Polymeric 245 - 240, 50 Hz Ex nR) V
Refractor C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
P4 - NEMA IV Polymeric C6 - 480, 60 Hz, CWI V
Refractor C7 - 600, 60 Hz, CWI V
P5 - NEMA V Polymeric TT - 120/277/347, 60 Hz,
Refractor CWA V

* Compliance data varies for specific fixtures. Consult Appleton regarding suitability of specific fixtures for a particular application.
➊ Other voltages, frequencies available – contact your local sales representative. Voltages shown are limited to specific combinations; refer to following pages.
➋ Polymeric Refractor suitable for Class II, Groups F and G, NEMA 4X and Marine Type Electric Fixtures Outside Type (Salt Water) only (100 W PSMH Max.).
Reflectors ordered separately.
➌ Available for 50-150 W HPS fixtures only.
➍ Available for HPS or PSMH fixtures.
➎ Not suitable for hazardous location per NEC/CEC V.
➏ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➐ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 923


© September 2010
Mercmaster™ III Low Profile Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Illustrated Features
Lighting

Vented Reflectors
Reflectors are thick, tough fiberglass-
Lighting: Enclosed and Gasketed — Area — HID

reinforced white polyester, vented for


cooler operation. Quickly attach with
furnished stainless steel screws. Ballast Assembly
Utilizing non-sparking components
High Temperature Sockets avoiding the ignition of gases or vapors
Medium base high-temperature porcelain Stainless Steel Inserts that may be present (nA).
sockets. Ballast bodies have stainless steel
threaded inserts to receive stainless steel Mounting Hood and Globe Gaskets
Aluminum Inner Reflector screws for reflectors and guard. Prevents Silicone rubber gaskets seals out
Solid aluminum inner reflector (for "freezing”, allowing guards and reflectors moisture, dirt and dust. Stays flexible,
refractor ballast housings only) improves to be easily removed and replaced at any withstands high temperatures. Closure
photometric efficiency. time, without damage to the housing. design assures uniform gasket
compression.
Globe Chamber Epoxy Finish
Completely sealed from the ballast Ballast housing, hoods and guards are Terminal Blocks (Zone 2)
housing and outside vapors/air (nR). copperfree aluminum with epoxy powder A seven-point terminal block is provided
coat finish. to facilitate wiring. Terminal block
Electrical Protection accommodates wire size ranging from #8
Ground wire provided to bond mounting Prismatic Glass Globes and Refractors to #24 AWG.
hood to ballast housing. Heat-resistant globes and refractors
thread directly into ballast housing and
seal against a high-temperature
silicone rubber gasket.

Cooler Operating Cone Hood


Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Fuses
Two screws secure fuse kit to mounting Stainless Steel
"Safety" High
boss in any Mercmaster mounting hood. Latch Assembly
Hinge
Fuse included. Captive, stainless
Extra-high hinge
steel latch
provides additional
assembly bolt
Photocell protection against
and nut closes
Available for all fixtures except cone and accidental
securely, resists
ceiling mount. Installs through knock-out ballast housing
attack of corrosive
in mounting hood. Provides continuous disengagement
atmospheres.
ON-OFF dusk-to-dawn control. during installation or
Swing-away design
maintenance.
simplifies servicing.

V CSA Certification Only.

924 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous exposure to hazardous conditions in both classifications
Temperature identification numbers of Mercmaster III Low Profile High Pressure Sodium and Pulse Start Metal Halide

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Class II, Division 1 Simultaneous Exposure


Supply
Lamp Class I, Division 2 Groups E, F and G Class I, Division 2 / Class II, Division 1
Wire Ambient
Temp. Temp. Globe & Globe & Globe &
Watts Type (°F/°C) (°F/°C) Globe Reflector Refractor Globe Reflector Refractor Globe Reflector Refractor

Lighting
194/90 104/40 T3 T3 T3B T4A T4A T5 T3 T3 T3
50 HPS 194/90 131/55 T3 T3 T3A T4A T4A T4A T2D T2D T2D
194/90 149/65 T3 T3 T3A T4 T4 T4A T2C T2C T2C
194/90 104/40 T3 T3 T3 T4 T4 T5 T2B T2B T2D
70 HPS 194/90 131/55 T2D T2D T3 T3C T3C T4A T2B T2B T2C
194/90 149/65 — — T3 — — T4 — — T2B

Lighting: Enclosed and Gasketed — Area — HID


194/90 104/40 T2C T2C T2D T4 T4 T4A T2B T2B T2B
100 HPS 194/90 131/55 T2B T2B T2C T3C T3C T4 T2A T2A T2A
194/90 149/65 — — — — — — — — —
150 HPS 194/90 104/40 T2A T2A T2B T3A * — T4 325 — T2
194/90 104/40 T3 T3 T3A T4A T4A T6 T2D T2D T3
50 PSMH 194/90 131/55 T3 T3 T3 T4 T4 T5 T2C T2C T2D
194/90 149/65 T3 T3 T3 T4 T4 T4A T2B T2B T2D
194/90 104/40 T3 T3 T3 T3C T3C T4A T2B T2B T2C
70 PSMH 194/90 131/55 T2D T2D T3 T3C T3C T4A T2A T2A T2B
230/110 149/65 — — T3 — — T4 — — T2B
194/90 104/40 T2A T2A T2B T3B T3B T4A T2 T2 T2A
100 PSMH
194/90 131/55 T2A T2A T2B T3A * T3A * T4 T1 T1 T2
150 PSMH 230/110 104/40 350 350 325 — — T3B — — T1
175 PSMH 230/110 104/40 350 350 325 — — T3B — — T1
175 MH V 230/110 104/40 — — 325 — — T3B — — —
194/90 104/40 T3B T3B T3C — — — — — —
60 Inc. 194/90 131/55 T3A T3A T3C — — — — — —
194/90 149/65 T3A T3A T3C — — — — — —
194/90 104/40 T3 T3 T3 — — — — — —
100 Inc. 194/90 131/55 T3 T3 T3 — — — — — —
194/90 149/65 T2D T2D T3 — — — — — —
194/90 104/40 T2D T2D T3 — — — — — —
150 Inc. 194/90 131/55 T2B T2B T2D — — — — — —
194/90 149/65 T2B T2B T2D — — — — — —

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” # T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

* “T” numbers are for Groups E and F only.


V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 925


© September 2010
Mercmaster™ III Low Profile Luminaire Thermal Performance
Class I, Zone 2, AEx nA nR IIC, AEx nR IIC IP66, NEMA 4X
Temperature identification numbers of Mercmaster III Zone 2 Low Profile High Pressure Sodium and Pulse Start Metal Halide.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Lamp Class I, Zone 2 AEx nA nR IIC / Ex nR IIC Class I, Zone 2 AEx nR IIC
Supply Wire Ambient Globe w/ Globe w/
Watts Type Temp. (°F/°C) Temp. (°F/°C) Globe Reflector Refractor Globe Reflector Refractor
194/90 104/40 T6 T6 T6 T6 T6 T6
Lighting

50 HPS 194/90 131/55 T5 T5 T5 T5 T5 T5


194/90 149/65 T4 T4 T5 T4 T4 T5
194/90 104/40 T5 T5 T5 T5 T5 T5
70 HPS 194/90 131/55 T4 T4 T4 T4 T4 T4
194/90 149/65 — — T4 — — T4
Lighting: Enclosed and Gasketed — Area — HID

194/90 104/40 T4 T4 T4 T4 T4 T4
100 HPS
194/90 131/55 T4 T4 T4 T4 T4 T4
150 HPS 194/90 104/40 T4 T4 T4 T4 T4 T4
194/90 104/40 T5 T5 T6 T5 T5 T6
50 PSMH 194/90 131/55 T5 T5 T6 T5 T5 T6
194/90 149/65 T4 T4 T5 T4 T4 T5
194/90 104/40 T5 T5 T6 T5 T5 T6
70 PSMH 194/90 131/55 T4 T4 T6 T4 T4 T6
230/110 149/65 — — T4 — — T4
194/90 104/40 T4 T4 T6 T4 T4 T6
100 PSMH
194/90 131/55 T4 T4 T4 T4 T4 T4
150 PSMH 221/105 104/40 T3 T3 T4 T3 T3 T4
175 PSMH 221/105 104/40 T3 T3 T4 T3 T3 T4
175 MH V 230/110 104/40 — — T3 — — —

“T” Numbers represent the maximum surface temperature for luminaries with AEx nA nR, Ex nR and AEx nR rating:
The “T” number is established by separately determining the maximum temperature of the globe surface and ballast compartment. The hotter of the two is taken
to determine the “T” number for the overall fixture.

“T” Number T1 T2 T3 T4 T5 T6
Temp. Range (°F) 547-842 394-572 277-392 214-275 187-212 185

Temp. Range (°C) 301-450 201-300 136-200 101-135 86-100 85

V CSA Certification Only.

926 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaires
50 W – 150 W HPS
High Power Factor (min. P.F. 90%). Medium base lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎➏


Lamp Type Lamp Watts (Inches) With Globe With Type V 8” Refractor ➋
Pendant — One Hub, Rigid Mounting 
3/4 MLAL502G1N MLAL502J5N

Lighting
HPS 50
1 MLAL503G1N MLAL503J5N
3/4 MLAL702G1N MLAL702J5N
HPS 70
1 MLAL703G1N MLAL703J5N
3/4 MLAL102G1N MLAL102J5N
HPS 100
1 MLAL103G1N MLAL103J5N
3/4 MLAL152G1N ➐ MLAL152J5N ➐

Lighting: Enclosed and Gasketed — Area — HID


Shown with Globe and Optional Guard HPS 150
1 MLAL153G1N ➐ MLAL153J5N ➐
Pendant Cone — One Hub, Rigid Mounting
3/4 MLDL502G1N MLDL502J5N
HPS 50
1 MLDL503G1N MLDL503J5N
3/4 MLDL702G1N MLDL702J5N
HPS 70
1 MLDL703G1N MLDL703J5N
3/4 MLDL102G1N MLDL102J5N
HPS 100
1 MLDL103G1N MLDL103J5N
3/4 MLDL152G1N ➐ MLDL152J5N ➐
HPS 150
Shown with Refractor 1 MLDL153G1N ➐ MLDL153J5N ➐
Ceiling — Five Hubs, Four Close-up Plugs
3/4 MLCL502G1N MLCL502J5N
HPS 50
1 MLCL503G1N MLCL503J5N
3/4 MLCL702G1N MLCL702J5N
HPS 70
1 MLCL703G1N MLCL703J5N
3/4 MLCL102G1N MLCL102J5N
HPS 100
1 MLCL103G1N MLCL103J5N
3/4 MLCL152G1N ➐ MLCL152J5N ➐
Shown with Globe HPS 150
1 MLCL153G1N ➐ MLCL153J5N ➐

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts LB MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
Inc. 150 Max. X — — — — — — — — — — — — —
HPS 50 — X — — — X X — X — — — — X
HPS 70 — X — X X X X — X — — — — X
HPS 100 — X — X X X X — X — — — — X
HPS 150 — X — X X X X — X X X X X X
PSMH 50 — X — X — — — — — — — — — X
PSMH 70 — X — X X X — — X — — — — X
PSMH 100 — X — X X X — — X — — — — X
PSMH 150 — X — X — — — — X — — — — X
PSMH 175 — X X X — — — — X — — — — X
MH V 175 — X — — — — — — — X X X X X
Voltages:
LB - Incandescent, 120 V 60 Hz 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 927


© September 2010
Mercmaster™ III Low Profile Luminaires
50 W – 150 W HPS
High Power Factor (min. P.F. 90%). Medium base lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎➏


Lamp Type Lamp Watts (Inches) With Globe With Type V 8” Refractor ➋
Wall ­— Five Hubs, Four Close-Up Plugs
3/4 MLWL502G1N MLWL502J5N
Lighting

HPS 50
1 MLWL503G1N MLWL503J5N
3/4 MLWL702G1N MLWL702J5N
HPS 70
1 MLWL703G1N MLWL703J5N
3/4 MLWL102G1N MLWL102J5N
HPS 100
1 MLWL103G1N MLWL103J5N
3/4 MLWL152G1N ➐ MLWL152J5N ➐
Lighting: Enclosed and Gasketed — Area — HID

HPS 150
Shown with Refractor and Optional Guard 1 MLWL153G1N ➐ MLWL153J5N ➐
25° Stanchion —
­ One Hub
1-1/4 MLSL504G1N MLSL504J5N
HPS 50
1-1/2 MLSL505G1N MLSL505J5N
1-1/4 MLSL704G1N MLSL704J5N
HPS 70
1-1/2 MLSL705G1N MLSL705J5N
1-1/4 MLSL104G1N MLSL104J5N
HPS 100
1-1/2 MLSL105G1N MLSL105J5N
1-1/4 MLSL154G1N ➐ MLSL154J5N ➐
HPS 150
Shown with Globe and Optional Guard 1-1/2 MLSL155G1N ➐ MLSL155J5N ➐
90° Stanchion —­ One Hub
1-1/4 MLRL504G1N MLRL504J5N
HPS 50
1-1/2 MLRL505G1N MLRL505J5N
1-1/4 MLRL704G1N MLRL704J5N
HPS 70
1-1/2 MLRL705G1N MLRL705J5N
1-1/4 MLRL104G1N MLRL104J5N
HPS 100
1-1/2 MLRL105G1N MLRL105J5N
1-1/4 MLRL154G1N ➐ MLRL154J5N ➐
HPS 150
Shown with Refractor and Optional Guard 1-1/2 MLRL155G1N ➐ MLRL155J5N ➐

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts LB MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
Inc. 150 Max. X — — — — — — — — — — — — —
HPS 50 — X — — — X X — X — — — — X
HPS 70 — X — X X X X — X — — — — X
HPS 100 — X — X X X X — X — — — — X
HPS 150 — X — X X X X — X X X X X X
PSMH 50 — X — X — — — — — — — — — X
PSMH 70 — X — X X X — — X — — — — X
PSMH 100 — X — X X X — — X — — — — X
PSMH 150 — X — X — — — — X — — — — X
PSMH 175 — X X X — — — — X — — — — X
MH V 175 — X — — — — — — — X X X X X
Voltages:
LB - Incandescent, 120 V 60 Hz 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.

928 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaires
50 W - 175 W PSMH
High Power Factor (min. P.F. 90%). Medium base lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎➏


Lamp Type Lamp Watts (Inches) With Globe With Type V 8” Refractor ➋
Pendant ­— One Hub, Rigid Mounting 
3/4 MLAH502G1N MLAH502J5N
PSMH 50

Lighting
1 MLAH503G1N MLAH503J5N
3/4 MLAH702G1N MLAH702J5N
PSMH 70
1 MLAH703G1N MLAH703J5N
3/4 MLAH102G1N MLAH102J5N
PSMH 100
1 MLAH103G1N MLAH103J5N
3/4 MLAP152G1N MLAP152J5N
PSMH 150
1 MLAP153G1N MLAP153J5N

Lighting: Enclosed and Gasketed — Area — HID


3/4 MLAP172G1N MLAP172J5N
Shown with Globe and Optional Guard PSMH 175
1 MLAP173G1N MLAP173J5N
Pendant Cone ­— One Hub, Rigid Mounting
3/4 MLDH502G1N MLDH502J5N
PSMH 50
1 MLDH503G1N MLDH503J5N
3/4 MLDH702G1N MLDH702J5N
PSMH 70
1 MLDH703G1N MLDH703J5N
3/4 MLDH102G1N MLDH102J5N
PSMH 100
1 MLDH103G1N MLDH103J5N
3/4 MLDP152G1N MLDP152J5N
PSMH 150
1 MLDP153G1N MLDP153J5N
3/4 MLDP172G1N MLDP172J5N
PSMH 175
Shown with Refractor 1 MLDP173G1N MLDP173J5N
Ceiling ­— Five Hubs, Four Close-up Plugs
3/4 MLCH502G1N MLCH502J5N
PSMH 50
1 MLCH503G1N MLCH503J5N
3/4 MLCH702G1N MLCH702J5N
PSMH 70
1 MLCH703G1N MLCH703J5N
3/4 MLCH102G1N MLCH102J5N
PSMH 100
1 MLCH103G1N MLCH103J5N
3/4 MLCP152G1N MLCP152J5N
PSMH 150
1 MLCP153G1N MLCP153J5N
3/4 MLCP172G1N MLCP172J5N
Shown with Globe PSMH 175
1 MLCP173G1N MLCP173J5N

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts LB MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
Inc. 150 Max. X — — — — — — — — — — — — —
HPS 50 — X — — — X X — X — — — — X
HPS 70 — X — X X X X — X — — — — X
HPS 100 — X — X X X X — X — — — — X
HPS 150 — X — X X X X — X X X X X X
PSMH 50 — X — X — — — — — — — — — X
PSMH 70 — X — X X X — — X — — — — X
PSMH 100 — X — X X X — — X — — — — X
PSMH 150 — X — X — — — — X — — — — X
PSMH 175 — X X X — — — — X — — — — X
MH V 175 — X — — — — — — — X X X X X
Voltages:
LB - Incandescent, 120 V 60 Hz 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 929


© September 2010
Mercmaster™ III Low Profile Luminaires
50 W - 175 W PSMH
High Power Factor (min. P.F. 90%). Medium base lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎➏


Lamp Type Lamp Watts (Inches) With Globe With Type V 8” Refractor ➋
Wall ­— Five Hubs, Four Close-Up Plugs
3/4 MLWH502G1N MLWH502J5N
Lighting

PSMH 50
1 MLWH503G1N MLWH503J5N
3/4 MLWH702G1N MLWH702J5N
PSMH 70
1 MLWH703G1N MLWH703J5N
3/4 MLWH102G1N MLWH102J5N
PSMH 100
1 MLWH103G1N MLWH103J5N
3/4 MLWP152G1N MLWP152J5N
PSMH 150
1 MLWP153G1N MLWP153J5N
Lighting: Enclosed and Gasketed — Area — HID

Shown with Refractor and Optional Guard 3/4 MLWP172G1N MLWP172J5N


PSMH 175
1 MLWP173G1N MLWP173J5N
25° Stanchion —
­ One Hub
1-1/4 MLSH504G1N MLSH504J5N
PSMH 50
1-1/2 MLSH505G1N MLSH505J5N
1-1/4 MLSH704G1N MLSH704J5N
PSMH 70
1-1/2 MLSH705G1N MLSH705J5N
1-1/4 MLSH104G1N MLSH104J5N
PSMH 100
1-1/2 MLSH105G1N MLSH105J5N
1-1/4 MLSP154G1N MLSP154J5N
PSMH 150
1-1/2 MLSP155G1N MLSP155J5N
1-1/4 MLSP174G1N MLSP174J5N
PSMH 175
Shown with Globe and Optional Guard 1-1/2 MLSP175G1N MLSP175J5N
90° Stanchion —­ One Hub
1-1/4 MLRH504G1N MLRH504J5N
PSMH 50
1-1/2 MLRH505G1N MLRH505J5N
1-1/4 MLRH704G1N MLRH704J5N
PSMH 70
1-1/2 MLRH705G1N MLRH705J5N
1-1/4 MLRH104G1N MLRH104J5N
PSMH 100
1-1/2 MLRH105G1N MLRH105J5N
1-1/4 MLRP154G1N MLRP154J5N
PSMH 150
1-1/2 MLRP155G1N MLRP155J5N
Shown with Refractor and Optional Guard 1-1/4 MLRP174G1N MLRP174J5N
PSMH 175
1-1/2 MLRP175G1N MLRP175J5N

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts LB MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
Inc. 150 Max. X — — — — — — — — — — — — —
HPS 50 — X — — — X X — X — — — — X
HPS 70 — X — X X X X — X — — — — X
HPS 100 — X — X X X X — X — — — — X
HPS 150 — X — X X X X — X X X X X X
PSMH 50 — X — X — — — — — — — — — X
PSMH 70 — X — X X X — — X — — — — X
PSMH 100 — X — X X X — — X — — — — X
PSMH 150 — X — X — — — — X — — — — X
PSMH 175 — X X X — — — — X — — — — X
MH V 175 — X — — — — — — — X X X X X
Voltages:
LB - Incandescent, 120 V 60 Hz 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.

930 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaire Mounting Hoods
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Mounting Hoods

Description Hub Size (Inches) Catalog Number


Pendant

Lighting
3/4 KPA-75
One Hub, Rigid Mounting
1 KPA-100

Pendant — Flexible
3/4 KPAF-75
One Hub, Flexible Mounting
1 KPAF-100

Lighting: Enclosed and Gasketed — Area — HID


Pendant Cone
3/4 KPCH-75
One Hub, Rigid or Flexible Mounting
1 KPCH-100

Ceiling
3/4 KPC-75
Five Hubs, Four Close-Up Plugs
1 KPC-100

Wall
3/4 KPWB-75
Five Hubs, Four Close-Up Plugs
1 KPWB-100

25° Stanchion
1-1/4 KPS-125
One Hub
1-1/2 KPS-150

90° Stanchion
1-1/4 KPST-125
One Hub
1-1/2 KPST-150

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 931


© September 2010
Mercmaster™ III Low Profile Luminaire Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Ballast Bodies
Lighting

Ballast Body for Glass Refractor Ballast Body for Glass Globe or Polymeric Refractor
High Pressure Sodium Pulse Start Metal Halide
High Power Factor (Min. P.F. 90%) Super Constant Wattage Autotransformer (Min. P.F. 90%)

Catalog Number ➍➎ Voltage Suffixes


Lamp Lamp
Type Watts For Globe For Refractor LB MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
Lighting: Enclosed and Gasketed — Area — HID

Inc. 150 Max. MLBG15I MLBR15I X — — — — — — — — — — — — —

HPS 50 MLBG50L ➊➋ MLBR50L ➊➋ — X — — — X X — X — — — — X

HPS 70 MLBG70L ➊➋ MLBR70L ➊➋ — X — X X X X — X — — — — X

HPS 100 MLBG10L ➊➋ MLBR10L ➊➋ — X — X X X X — X — — — — X

HPS 150 MLBG15L ➊➋ MLBR15L ➊➋ — X — X X X X — X X X X X X

PSMH 50 MLBG50H ➋➌ MLBR50H ➋➌ — X — X — — — — — — — — — X

PSMH 70 MLBG70H ➋➌ MLBR70H ➋➌ — X — X X X — — X — — — — X

PSMH 100 MLBG10H ➋➌ MLBR10H ➋➌ — X — X X X — — X — — — — X

PSMH 150 MLBG15P ➋➌ MLBR15P ➋➌ — X — X — — — — X — — — — X

PSMH 175 MLBG17P ➋➌ MLBR17P ➋➌ — X X X — — — — X — — — — X

MH V 175 MLBG17H ➋ MLBR17H ➋ — X — — — — — — — X X X X X

Voltages:
LB - Incandescent, 120 V 60 Hz 235 - 230 V 50 Hz
MT - 120/208/240/277 V 60 Hz 245 - 240 V 50 Hz
5MT - 120/208/240/277/480 V 60 Hz C2 - 208 V 60 Hz, CWI V
48 - 480 V 60 Hz C3 - 240 V 60 Hz, CWI V
125 - 120 V 50 Hz C6 - 480 V 60 Hz, CWI V
225 - 225 V 50 Hz C7 - 600 V 60 Hz, CWI V,
226 - 220 V 60 Hz TT - 120/277/347 V 60 Hz, CWA V

➊ After voltage suffix add: -S for Smart Starter, -SR for Smart Hot Restrike, -R for ballast body with Hot Restrike Ignitor.
➋ Add -E after voltage suffix for ballast body with provision for Quartz Emergency Light. Not suitable for hazardous locations.
➌ After voltage suffix add: -S for Smart Starter.
➍ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➎ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification Only.

932 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaire Accessories and Replacement Parts
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Description Catalog Number


Prismatic Glass Globes ­— Heat-Resistant
Clear VPGL-1HR
Amber VPGL-1AM

Lighting
Blue VPGL-1BL
Green VPGL-1GR
Glass Globe Red VPGL-1RE
Light Distribution IES/NEMA Distribution Curves Catalog Number
Closed Prismatic Glass Refractors — All Heat-Resistant

Lighting: Enclosed and Gasketed — Area — HID


NEMA Type I LPG-R1

NEMA Type III LPG-R3

Glass Refractor NEMA Type V LPG-R5

Closed Prismatic Polymeric Refractors — For Use with PSMH Lamps


100 W max. 104 °F/40 °C max. ambient temperature. Suitable for Class II, Division 1 and 2, Groups F, G;
NEMA 4X, UL 1598A Marine Type Electric Fixtures Outside Type (Salt Water)

NEMA Type II LPRF-2CP

NEMA Type III LPRF-3CP

NEMA Type IV LPRF-4CP

Polymeric Refractor
NEMA Type V LPRF-5CP

Description Catalog Number


White Polyester Reflectors — Furnished with stainless steel screws
Standard Dome KR2-ST
For Globe Fixtures Deep Dome KR2-DD ➊
30° Angle KR2-AN
Standard Dome CMR-4ST ➋
For Glass Refractor Fixtures Deep Dome CMR-4DD ➊
Standard Dome 30° Angle 30° Angle CMR-4AN
Guards
Globe Guard KGU1
Refractor Guard KRG2

Globe Guard Refractor Guard


Replacement Globe Gaskets — Silicone Rubber
Globe Gasket VPGL-GK
Refractor Gasket KRF-GK
Globe Gaskets
➊ Dark Skies Compliant.
➋ Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 933


© September 2010
Mercmaster™ III Low Profile Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Electrical Specifications Electrical Specifications


Line Type of Starting Operating Total Line Type of Starting Operating Total
Voltage Ballast ➊ Amps Amps Watts Voltage Ballast ➊ Amps Amps Watts
50 Watt High Pressure Sodium 150 Watt Pulse Start Metal Halide
120 HX-HPF 0.58 0.58 64 120 HX-HPF 1.75 1.60 188
Lighting

208 HX-HPF 0.35 0.33 64 208 HX-HPF 1.30 1.00 188


240 HX-HPF 0.31 0.29 64 240 HX-HPF 0.85 0.80 188
277 HX-HPF 0.25 0.25 64 277 HX-HPF 0.77 0.70 188
347 V HX-HPF 0.26 0.21 68 347 V Super C.W.A. 0.65 0.55 185
70 Watt High Pressure Sodium 480 Super C.W.A. 0.45 0.42 185
120 HX-HPF 0.90 0.82 94 175 Watt Pulse Start Metal Halide
208 HX-HPF 0.50 0.48 94 120 Super C.W.A. 0.90 1.78 199
Lighting: Enclosed and Gasketed — Area — HID

240 HX-HPF 0.44 0.41 94 208 Super C.W.A. 0.50 1.08 199
277 HX-HPF 0.35 0.36 94 240 Super C.W.A. 0.35 0.89 199
347 V HX-HPF 0.30 0.30 94 277 Super C.W.A. 0.30 0.76 199
480 HX-HPF 0.21 0.21 94 347 V Super C.W.A. 0.25 0.65 208
100 Watt High Pressure Sodium 480 Super C.W.A. 0.25 0.50 213
120 HX-HPF 1.30 1.15 130 175 Watt Metal Halide V
208 HX-HPF 0.76 0.67 130 120 C.W.A. 1.30 1.80 210
240 HX-HPF 0.66 0.60 130 208 C.W.A. 0.75 1.04 210
277 HX-HPF 0.60 0.52 130 240 C.W.A. 0.65 0.90 210
347 V HX-HPF 0.45 0.39 130 277 C.W.A. 0.55 0.80 210
480 HX-HPF 0.33 0.31 135 347 C.W.A. 0.50 0.65 210
480 C.W.I. 0.17 0.30 130 480 C.W.I. 0.20 0.45 215
600 C.W.I. 0.14 0.24 130 600 C.W.I. 0.16 0.37 215
150 Watt High Pressure Sodium ➋ Fuse Kit for Field Installation
120 HX-HPF 2.00 1.70 188 Lamp Fuse Quantity Fuse Kit Catalog Number
208 HX-HPF 1.15 0.95 188 Watts Volts Required HPS PSMH
240 HX-HPF 1.00 0.85 188 120 1 F5 F3
277 HX-HPF 0.85 0.72 188 208 2 F3 F3
347 V HX-HPF 0.52 0.56 188 50W 240 2 F3 F2
480 HX-HPF 0.50 0.47 189 277 1 F2 F2
347 V 1 F1 F1
480 C.W.I. 0.25 0.42 190
120 1 F5 F4
600 C.W.I. 0.19 0.35 190 208 2 F3 F3
50 Watt Pulse Start Metal Halide 240 2 F3 F3
120 HX-HPF 0.87 0.62 67 70W
277 1 F2 F2
208 HX-HPF 0.51 0.40 67 347 V 1 F1 F2
240 HX-HPF 0.47 0.35 67 480 2 F2 F1
277 HX-HPF 0.32 0.32 67 120 1 F8 F6
347 V HX-HPF 0.15 0.20 67 208 2 F5 F4
240 2 F5 F3
70 Watt Pulse Start Metal Halide 100W
277 1 F3 F3
120 HX-HPF 0.80 0.85 95 1 F1 F2
347 V
208 HX-HPF 0.50 0.52 95 480 2 F3 F2
240 HX-HPF 0.43 0.44 95 120 1 F10 F10
277 HX-HPF 0.39 0.39 95 208 2 F5 F5
347 V HX-HPF 0.20 0.28 88 240 2 F5 F5
150W
480 HX-HPF 0.26 0.23 95 277 1 F5 F4
100 Watt Pulse Start Metal Halide 347 V 1 F2 F2
120 HX-HPF 1.20 1.15 130 480 2 F3 F3
120 1 — F5
208 HX-HPF 0.70 0.70 130
208 2 — F3
240 HX-HPF 0.61 0.58 130 240 2 — F3
277 HX-HPF 0.55 0.50 130 175W
277 1 — F2
347 V HX-HPF 0.40 0.40 129 347 V 1 F2 F2
480 HX-HPF 0.30 0.35 140 480 2 — F2
➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance High Power Factor Autotransformer. Super C.W.A. – Super Constant Wattage Autotransformer.
➋ 150 W HPS units equipped with ballasts to operate 55 V lamps only.
V CSA Certification Only.

934 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaire Dimensions and Weights
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Pendant (Rigid or Flex) Pendant Cone Ceiling 25º Stanchion


1.17”/ 12.06”/306.0 mm 13.62”/346.0 mm 1.75”/
30.0 mm 45.0 mm
12.06”/306.0 mm 12.06”/306.0 mm 15.28”/ 2.00”/
388.0 mm 51.0 mm
5.59”/
142.0 mm

Lighting
9.25”/
235.0 mm

12.05”/
306.0 mm

Wall Mount 90º Stanchion


17.01”/ 17.23”/438.0 mm 7.60”/
3.38”/
432.0 mm 85.8 mm 193.0 mm
10.94”/ (4) Mounting Holes 9.79”/249.0 mm
278.0 mm 0.31”/8.0 mm

Lighting: Enclosed and Gasketed — Area — HID


4.06”/
103.0 mm

12.05”/
306.0 mm 12.06”/306.0 mm

Globe or Polymeric Refractor Ballast 8" Glass Refractor Ballast Housing Standard Polyester Reflector 30º Angle Polyester Reflector
Housing

Globe, Guard and Refractors Refractor Body, Refractor and Guard Polymeric Refractor Deep Dome

Mercmaster III Low Profile Ballast and Accessory Weights ➊


Globe Housing Ballast (Wt. Lbs/Kg) Refractor Housing Ballast (Wt. Lbs/Kg) Mounting Wt. Refractors, Globes, Wt.
Watts HPS PSMH HPS PSMH Hoods Lbs/Kg Guards and Reflectors Lbs/Kg
50 7.25/3.3 7.00/3.2 7.75/3.5 7.50/3.4 Pendant 2.25/1.0 8” Glass Refractor 5.25/2.4
70 8.25/3.7 7.75/3.5 8.75/4.0 8.25/3.7 Pendant Cone 2.50/1.1 Glass Globe 3.75/1.7
100 9.75/4.4 9.25/4.2 10.25/4.6 9.75/4.4 Ceiling 3.00/1.4 Refractor Guard 1.00/0.5
150 10.75/4.9 10.75/4.9 11.25/5.1 11.25/5.1 Wall 4.00/1.8 Globe Guard 1.00/0.5
175 — 11.00/5.0 — 11.50/5.2 25° Stanchion 3.25/1.5 Standard Dome 2.50/1.1
90° Stanchion 3.75/1.7 Deep Dome 5.00/2.3
30° Angle 2.50/1.1
Polymeric Refractor 2.43/1.1

➊ Weights are approximate. Add 0.25 lbs/0.1 kg for Quartz option.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 935


© September 2010
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED

Class I, Division 2, Groups A, B, C, D


NEMA 4X

Applications Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn • Encapsulated with epoxy sealing compound
lighting control in Class I, Division 2 locations. • FS: aluminum
• Typical applications include walkways, security areas and any
other outdoor lighting application.
Certifications and Compliances
Lighting

• For use with Mercmaster III – Low Profile, Mercmaster III, and • UL Standard: 1604 ­– Hazardous (Classified) Locations
Mercmaster III – 400 Series Luminaires. • cULus Recognized
• For remote mounting in FS Boxes.
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
Lighting: Enclosed and Gasketed — Area — HID

• Solid state design for performance and reliability.


• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 V.A. Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisiance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
• Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1. Dimensions
Voltage Range Suffix Designation
120 V, 50/60 Hz H1
208 V, 50/60 Hz H2
240 V, 50/60 Hz H3
277 V, 50/60 Hz H4
Mercmaster III wall mounting hood
with photocontrol installed shown
1.13”
28.7 mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box


Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range Catalog Number


120V, 50/60 Hz FSKA-PC120D2
1.375”
34.9 mm
208-277V, 50/60 Hz FSKA-PC247D2 1.375”
34.9 mm

2.56”
65.0 mm
2.56”
1.13” 65.0 mm
28.7 mm

Photocontrol for Field Installation


Voltage Range Max. Current Catalog Number
120 V, 50/60 Hz 8.3 Amp PC120D2
1.375”
208-277 V, 50/60 Hz 3.5 Amp PC247D2
34.9 mm 0.69”
17.5 mm

1.19”
2.56” 30.2 mm
65.0 mm 1.94”
49.2 mm

936 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on a fixture with For candlepower values of fixtures with other
a 150-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers: for
(16,000 lumen). a 100 W (9,500 lumen) HPS lamp – 0.594; for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by – 0.95.

Zone Lumens Total Luminaire Efficiency = 83%

0-10 28.58 CIE Type – Semi-Direct REPORT NUMBER: ML15LG


10-20 123.97 Lamps: 150 W High Pressure Sodium with Globe only *
Spacing
20-30 304.16 Plane Criteria

Lighting
30-40 513.64 0-180 3.9 Coefficients of Utilization – Zonal Cavity Method

40-50 889.19 90-270 3.9 Effective Floor Cavity Reflectance 0.20

50-60 1299.53 Diagonal 3.7 % Ceiling Rcc 80 70 50 30 10 0

60-70 1506.73 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 1706.16 Zonal Lumen Summary 0 91 91 91 91 85 85 85 85 75 75 75 65 65 65 55 55 55 51

Lighting: Enclosed and Gasketed — Area — HID


80-90 1800.53 Zone Lumens % Lamp % Fixture 1 77 71 66 61 72 66 61 57 57 53 49 48 45 42 40 37 35 31
90-100 1791.58 0-30 4563.72 2.9 3.4 2 68 59 51 45 63 55 48 42 46 41 36 39 34 31 32 28 25 21
100-110 1652.69 0-40 970.35 6.1 7.3 3 61 50 42 35 56 46 39 33 39 33 28 32 27 23 26 22 19 16
110-120 1311.22 0-60 3159.07 19.7 23.8 4 55 43 35 28 50 40 32 26 34 27 22 28 23 18 22 18 15 12
120-130 351.25 0-90 8172.49 51.1 61.5 5 50 38 29 23 46 35 27 21 29 23 18 24 19 15 19 15 12 9
130-140 5.14 90-120 4755.49 29.7 35.8 6 46 33 25 19 42 31 23 18 26 20 15 21 16 12 17 13 10 7
140-150 0.00 90-130 5106.74 31.9 38.4 7 42 30 22 16 38 27 20 15 23 17 13 19 14 10 15 11 8 6
150-160 0.00 90-150 5111.87 31.9 38.4 8 39 27 19 14 36 25 18 13 21 15 11 17 12 9 14 10 7 5
160-170 0.00 90-180 5111.87 31.9 38.5 9 36 24 17 12 33 22 16 11 19 13 9 16 11 8 13 9 6 4
170-180 0.00 0-180 13284.37 83.0 100.0 10 33 22 15 11 31 20 14 10 17 12 8 15 10 7 12 8 5 4

Zone Lumens Total Luminaire Efficiency = 73.2%

0-10 219.96 CIE Type – Direct REPORT NUMBER: ML15LST


10-20 683.41 Lamps: 150 W High Pressure Sodium with
Spacing
20-30 1267.92 Plane Criteria Standard Dome Reflector *
30-40 1613.68 0-180 1.64 Coefficients of Utilization – Zonal Cavity Method

40-50 1967.79 90-270 1.64 Effective Floor Cavity Reflectance 0.20

50-60 2333.86 Diagonal 1.88 % Ceiling Rcc 80 70 50 30 10 0

60-70 2328.33 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 1118.52 Zonal Lumen Summary 0 87 87 87 87 85 85 85 85 81 81 81 78 78 78 75 75 75 73

80-90 174.91 Zone Lumens % Lamp % Fixture 1 79 75 71 68 77 73 70 67 70 67 65 67 65 63 64 62 61 59


90-100 1.23 0-30 2171.29 13.6 18.5 2 70 63 58 53 68 62 57 52 59 55 51 57 53 50 55 52 49 47
100-110 0.00 0-40 3784.97 23.7 32.3 3 63 54 48 42 61 53 47 42 51 46 41 49 44 40 47 43 40 38
110-120 0.00 0-60 8086.62 50.5 69.1 4 57 47 40 35 55 46 39 34 44 38 34 42 37 33 41 36 33 31

120-130 0.00 0-90 11708.37 73.2 100.0 5 52 41 34 29 50 41 34 29 39 33 28 37 32 28 36 31 28 26


130-140 0.00 90-120 1.23 0.0 0.0 6 48 37 30 24 46 36 29 24 35 29 24 33 28 24 32 27 24 22
140-150 0.00 90-130 1.23 0.0 0.0 7 44 33 26 21 42 32 26 21 31 25 21 30 25 21 29 24 20 19
150-160 0.00 90-150 1.23 0.0 0.0 8 41 30 23 18 39 29 23 18 28 22 18 27 22 18 26 22 18 16
160-170 0.00 90-180 1.23 0.0 0.0 9 38 27 21 16 37 27 20 16 26 20 16 25 20 16 24 19 16 14
170-180 0.00 0-180 11709.6 73.2 100.0 10 35 25 19 15 34 24 18 14 24 18 14 23 18 14 22 18 14 13

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 937


© September 2010
Mercmaster™ III Low Profile Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on a fixture with For candlepower values of fixtures with other
a 150-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers: for
(16,000 lumen). a 100 W (9,500 lumen) HPS lamp – 0.594; for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by – 0.95.

Zone Lumens Total Luminaire Efficiency = 68.4%

0-10 168.01 CIE Type – Direct REPORT NUMBER: ML15LAN


10-20 536.92 Lamps: 150 W High Pressure Sodium with
Spacing
30° Angle Dome Reflector *
Lighting

20-30 972.38 Plane Criteria

30-40 1342.99 0-180 2.3 Coefficients of Utilization – Zonal Cavity Method

40-50 1625.08 90-270 2.0 Effective Floor Cavity Reflectance 0.20

50-60 1721.88 Diagonal 1.8 % Ceiling Rcc 80 70 50 30 10 0

60-70 1586.98 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0


Lighting: Enclosed and Gasketed — Area — HID

70-80 1369.71 Zonal Lumen Summary 0 80 80 80 80 78 78 78 78 74 74 74 70 70 70 66 66 66 64

80-90 995.76 Zone Lumens % Lamp % Fixture 1 70 66 62 58 68 64 60 57 60 57 54 57 54 52 54 52 50 48


90-100 461.94 0-30 1677.30 10.5 15.3 2 63 56 50 45 60 54 49 44 51 46 42 48 44 41 45 42 39 37
100-110 127.24 0-40 3020.29 18.9 27.6 3 56 48 41 36 54 46 40 35 44 38 34 41 37 33 39 35 32 30
110-120 27.54 0-60 6367.25 39.8 58.2 4 51 42 35 29 49 40 34 29 38 32 28 36 31 27 34 30 26 24
120-130 4.31 0-90 10319.70 64.5 94.3 5 47 37 30 24 45 36 29 24 34 28 23 32 27 23 30 26 22 20
130-140 2.68 90-120 616.71 3.9 5.6 6 43 33 26 21 41 32 25 20 30 24 20 28 23 19 27 22 19 17
140-150 0.00 90-130 621.02 3.9 5.7 7 39 29 23 18 38 28 22 18 27 21 17 26 21 17 24 20 16 15
150-160 0.00 90-150 623.70 3.9 5.7 8 37 26 20 16 35 26 20 15 24 19 15 23 18 15 22 18 14 13
160-170 0.00 90-180 623.70 3.9 5.7 9 34 24 18 14 33 23 18 14 22 17 13 21 17 13 20 16 13 11
170-180 0.00 0-180 10943.41 68.4 100.0 10 32 22 16 12 31 22 16 12 21 15 12 20 15 12 19 15 11 10

Zone Lumens Total Luminaire Efficiency = 77.6%

0-10 16.51 CIE Type – Semi-Direct REPORT NUMBER: ML15LJ5


10-20 135.03 Lamps: 150 W High Pressure Sodium with
Spacing
20-30 274.24 Plane Criteria 8” Prismatic Glass Refracter – NEMA Type V *
30-40 463.44 0-180 2.22 Coefficients of Utilization – Zonal Cavity Method

40-50 1125.38 90-270 2.20 Effective Floor Cavity Reflectance 0.20

50-60 1688.89 Diagonal 3.50 % Ceiling Rcc 80 70 50 30 10 0

60-70 3137.76 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 2421.27 Zonal Lumen Summary 0 89 89 89 89 86 86 86 86 79 79 79 73 73 73 68 68 68 65

80-90 1145.98 Zone Lumens % Lamp % Fixture 1 76 70 65 60 72 67 62 58 61 57 54 56 53 50 51 48 46 43


90-100 411.16 0-30 425.77 2.7 3.4 2 66 56 49 42 62 54 47 41 49 43 38 44 39 35 40 36 32 29
100-110 632.32 0-40 889.22 5.6 7.2 3 58 46 38 31 54 44 36 30 40 33 27 36 30 25 32 27 23 21
110-120 448.30 0-60 3703.50 23.1 29.8 4 51 39 30 23 48 37 29 22 33 26 21 30 24 19 27 22 17 15
120-130 293.08 0-90 10408.50 65.1 83.8 5 46 34 25 18 43 32 24 18 29 22 16 26 20 15 23 18 13 11
130-140 154.61 90-120 1491.78 9.3 12.0 6 42 29 21 15 40 28 20 14 25 18 13 22 16 12 20 15 11 8
140-150 59.30 90-130 1784.86 11.2 14.4 7 39 26 18 12 36 25 17 12 22 15 11 20 14 10 18 13 9 7
150-160 9.99 90-150 1998.77 12.5 14.4 8 36 23 15 10 33 22 15 10 20 13 9 18 12 8 16 11 7 5
160-170 0.49 90-180 2009.26 12.6 16.2 9 33 21 14 9 31 20 13 8 18 12 8 16 11 7 15 10 6 4
170-180 0.00 0-180 12417.76 77.6 100.0 10 31 19 12 8 29 18 12 7 17 11 7 15 10 6 13 9 5 4

938 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Luminaire Photometric Data
100 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on a fixture with For candlepower values of fixtures with other For candlepower values of fixture with guard,
a 100-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: multiply by – 0.95.
(8,500 lumen). for a 50 W (3400 lumen) PSMH lamp – 0.40; for
a 70 W (5600 lumen) PSMH lamp – 0.66; for a
150 W (10,500 lumen) PSMH lamp – 1.24; for
a 175 W (17,500 lumen) PSMH lamp – 2.06.

Zone Lumens Total Luminaire Efficiency = 85.7%

0-10 21.19 CIE Type – Semi-Direct REPORT NUMBER: ML10HG


10-20 93.55 Lamps: 100 W Pulse Start Metal Halide with Globe only *
Spacing

Lighting
20-30 201.68 Plane Criteria

30-40 291.92 0-180 3.20 Coefficients of Utilization – Zonal Cavity Method

40-50 523.42 90-270 3.20 Effective Floor Cavity Reflectance 0.20

50-60 637.38 Diagonal 3.08 % Ceiling Rcc 80 70 50 30 10 0

60-70 732.34 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Lighting: Enclosed and Gasketed — Area — HID


70-80 845.58 Zonal Lumen Summary 0 95 95 95 95 89 89 89 89 78 78 78 68 68 68 58 58 58 54

80-90 874.42 Zone Lumens % Lamp % Fixture 1 81 74 69 64 75 69 64 60 60 56 52 51 48 45 43 40 38 34


90-100 870.80 0-30 316.42 4.1 4.7 2 71 62 54 48 66 57 50 45 49 43 39 41 37 33 34 31 28 24
100-110 809.33 0-40 608.33 7.8 9.1 3 64 52 44 37 59 49 41 35 41 35 30 35 30 26 29 25 21 18
110-120 643.44 0-60 1769.13 22.7 26.5 4 57 45 37 30 53 42 34 28 36 29 24 30 25 20 25 20 17 14
120-130 139.00 0-90 4221.46 54.1 63.2 5 52 40 31 25 48 37 29 23 31 25 20 26 21 17 21 17 14 11
130-140 0.71 90-120 2323.56 29.8 34.8 6 48 35 27 21 44 33 25 19 28 21 17 23 18 14 19 15 11 9
140-150 0.00 90-130 2462.56 31.6 36.8 7 44 31 23 17 40 29 22 16 25 19 14 21 16 12 17 13 10 7
150-160 0.00 90-150 2463.27 31.6 36.8 8 41 28 20 15 37 26 19 14 22 16 12 19 14 10 16 11 8 6
160-170 0.00 90-180 2463.27 31.6 36.8 9 38 26 18 13 35 24 17 12 20 15 11 17 12 9 14 10 7 5
170-180 0.00 0-180 6684.73 85.7 100.0 10 35 23 16 12 32 22 15 11 19 13 9 16 11 8 13 9 6 5

Zone Lumens Total Luminaire Efficiency = 75.8%

0-10 116.29 CIE Type – Direct REPORT NUMBER: ML10HST


10-20 371.61 Lamps: 100 W Pulse Start Metal Halide with
Spacing
20-30 692.88 Plane Criteria Standard Dome Reflector *
30-40 821.73 0-180 1.70 Coefficients of Utilization – Zonal Cavity Method

40-50 1064.03 90-270 1.70 Effective Floor Cavity Reflectance 0.20

50-60 1154.58 Diagonal 1.84 % Ceiling Rcc 80 70 50 30 10 0

60-70 1134.19 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 470.22 Zonal Lumen Summary 0 90 90 90 90 88 88 88 88 84 84 84 81 81 81 77 77 77 76

80-90 83.66 Zone Lumens % Lamp % Fixture 1 82 78 74 71 80 76 73 70 73 70 68 70 68 66 67 65 64 62


90-100 0.82 0-30 1180.78 15.1 20.0 2 73 66 61 56 71 65 60 55 62 58 54 60 56 53 57 54 51 50
100-110 0.00 0-40 2002.50 25.7 33.9 3 66 57 50 45 64 56 50 45 54 48 44 51 47 43 49 46 42 40
110-120 0.00 0-60 4221.11 54.1 71.4 4 60 50 43 37 58 49 42 37 47 41 36 45 40 36 43 39 35 33
120-130 0.00 0-90 5909.17 75.8 100.0 5 54 44 36 31 53 43 36 31 41 35 30 40 34 30 38 33 30 28
130-140 0.00 90-120 0.82 0.0 0.0 6 50 39 32 26 48 38 31 26 37 31 26 35 30 26 34 29 25 24
140-150 0.00 90-130 0.82 0.0 0.0 7 46 35 28 23 45 34 27 23 33 27 22 32 26 22 31 26 22 20
150-160 0.00 90-150 0.82 0.0 0.0 8 43 32 25 20 41 31 24 20 30 24 20 29 24 20 28 23 19 18
160-170 0.00 90-180 0.82 0.0 0.0 9 40 29 22 18 38 28 22 18 27 22 17 27 21 17 36 21 17 16
170-180 0.00 0-180 5910.00 75.8 100.0 10 37 26 20 16 36 26 20 16 25 20 16 24 19 16 24 19 15 14

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 939


© September 2010
Mercmaster™ III Low Profile Luminaire Photometric Data
100 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on a fixture with For candlepower values of fixtures with other For candlepower values of fixture with guard,
a 100-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: multiply by – 0.95.
(8,500 lumen). for a 50 W (3400 lumen) PSMH lamp – 0.40; for
a 70 W (5600 lumen) PSMH lamp – 0.66; for a
150 W (10,500 lumen) PSMH lamp – 1.24; for
a 175 W (17,500 lumen) PSMH lamp – 2.06.

Zone Lumens Total Luminaire Efficiency = 71.3%

0-10 91.83 CIE Type – Direct REPORT NUMBER: ML10HAN


10-20 301.65 Lamps: 100 W Pulse Start Metal Halide with
Spacing
30° Angle Dome Reflector *
Lighting

20-30 543.23 Plane Criteria

30-40 703.02 0-180 2.08 Coefficients of Utilization – Zonal Cavity Method

40-50 877.11 90-270 2.06 Effective Floor Cavity Reflectance 0.20

50-60 850.33 Diagonal 1.76 % Ceiling Rcc 80 70 50 30 10 0

60-70 7753.51 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0


Lighting: Enclosed and Gasketed — Area — HID

70-80 667.27 Zonal Lumen Summary 0 84 84 84 84 82 82 82 82 77 77 77 73 73 73 69 69 69 68

80-90 471.44 Zone Lumens % Lamp % Fixture 1 74 69 65 62 71 67 64 60 63 60 58 60 57 55 57 55 53 51


90-100 200.90 0-30 936.72 12.0 16.8 2 66 59 53 48 64 57 51 47 54 49 45 51 47 43 48 45 42 40
100-110 62.89 0-40 1639.74 21.0 29.5 3 59 51 44 38 57 49 43 38 46 41 36 44 39 35 41 37 34 32
110-120 14.42 0-60 3367.18 43.2 60.6 4 54 44 37 31 52 43 36 31 40 35 30 38 33 29 36 32 28 27
120-130 1.07 0-90 5281.39 67.7 95.0 5 49 39 32 26 47 38 31 26 36 30 25 34 29 25 32 28 24 22
130-140 0.00 90-120 278.21 3.6 5.0 6 45 35 28 23 43 34 27 22 32 26 22 30 25 21 29 24 21 19
140-150 0.00 90-130 279.28 3.6 5.0 7 42 31 24 20 40 30 24 19 29 23 19 27 22 18 26 22 18 16
150-160 0.00 90-150 279.28 3.6 5.0 8 39 28 22 17 37 28 21 17 26 21 17 25 20 16 24 19 16 14
160-170 0.00 90-180 279.28 3.6 5.0 9 36 26 19 15 35 25 19 15 24 19 15 23 18 14 22 17 14 13
170-180 0.00 0-180 5560.68 71.3 100.0 10 34 24 18 14 32 23 17 13 22 17 13 21 16 13 20 16 13 11

Zone Lumens Total Luminaire Efficiency = 76.6%

0-10 9.17 CIE Type – Semi-Direct REPORT NUMBER: ML10HJ5


10-20 75.43 Lamps: 100 W Pulse Start Metal Halide with
Spacing
20-30 154.76 Plane Criteria 8” Prismatic Glass Refracter – NEMA Type V *
30-40 266.34 0-180 2.06 Coefficients of Utilization – Zonal Cavity Method

40-50 632.54 90-270 2.20 Effective Floor Cavity Reflectance 0.20

50-60 1155.59 Diagonal 3.26 % Ceiling Rcc 80 70 50 30 10 0

60-70 1665.76 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 693.73 Zonal Lumen Summary 0 89 89 89 89 85 85 85 85 79 79 79 73 73 73 68 68 68 65

80-90 449.28 Zone Lumens % Lamp % Fixture 1 77 71 67 62 73 68 64 60 63 59 56 58 55 52 53 51 49 46


90-100 177.44 0-30 239.35 3.1 4.0 2 67 58 51 45 64 56 49 44 51 46 41 47 42 38 43 39 36 33
100-110 288.25 0-40 505.69 6.5 8.5 3 59 48 40 34 56 46 39 32 42 36 30 38 33 28 34 30 26 24
110-120 208.52 0-60 2293.81 29.4 38.4 4 52 41 32 26 49 39 31 25 35 28 23 32 26 21 29 24 20 18
120-130 128.19 0-90 5102.58 65.4 85.4 5 47 35 26 20 44 33 25 19 30 23 18 27 21 17 25 20 15 13
130-140 56.80 90-120 674.20 8.6 11.3 6 43 30 22 16 40 29 21 15 26 19 14 24 18 13 21 16 12 10
140-150 14.94 90-130 802.38 10.3 13.4 7 39 27 19 13 37 25 18 13 23 16 12 21 15 11 19 14 10 8
150-160 0.10 90-150 874.12 11.2 13.4 8 36 24 16 11 34 23 15 10 21 14 10 19 13 9 17 12 8 6
160-170 0.00 90-180 874.22 11.2 14.6 9 33 21 14 9 31 20 14 9 19 12 8 17 11 8 15 10 7 5
170-180 0.00 0-180 5976.80 76.6 100.0 10 31 19 12 8 29 19 12 8 17 11 7 15 10 6 14 9 6 4

940 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors or combustible

Lighting
dusts are present under conditions defined by the National
Electrical Code as Class I, Division 2; Class II, Division 1 and
2; and Class III
— For Zone 2, the method of protection is AEx nA nR –
Restricted Breathing/Nonsparking or AEx nR – Restricted
Breathing
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or

Lighting: Enclosed and Gasketed — Area — HID


high ambient temperatures are encountered. 18% cooler Pendant Mount Fixture Straight Stanchion-Mount Fixture
operation allows use in ambient temperatures up to with Prismatic Glass Refractor with Prismatic Glass Refractor and
149°F/65°C depending on fixture component combinations Guard
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Marine applications
• Fixtures have NEMA 4X listing.
• Suitability includes listing for use where there may be
simultaneous exposure to combustible dusts and flammable
gases and vapors. See listing pages for compliance data on
specific fixture component combinations.
Features
• Modular design allows scores of fixture component
combinations to meet installation and lighting needs. Many Ceiling Mount Fixture
Pendant Cone Fixture with
most-used combinations are offered prewired and assembled, with Prismatic Glass Globe, Guard
complete with lamp, packaged in a single carton and ready to Prismatic Glass Globe and Guard
and Polyester 30° Angle Reflector
install.
• Mogul lamp types and wattages:
HPS 50W-150W • Reflector choice includes standard dome and 30º angle types,
PSMH 70W-250W both made of Fiberglass reinforced white polyester. Highly
• Choice of heat-resistant prismatic glass refractors (NEMA resistant to unusually corrosive applications. Reflectors are
distributions I, III and V), or heat-resistant prismatic glass globes vented for cooler, dirt-free operation and maintained lumen
for hazardous area fixtures. Colored and clear polycarbonate output. They secure to ballast housing with stainless steel
globes and Tuff-skin® † coated glass globes are available but are screws threading into stainless steel inserts.
NOT approved for use in classified areas. Fixtures with these • For high corrosion resistance, fixture housing, mounting hoods
globes do NOT comply with code requirements, and should be and guards are copperfree cast aluminum with baked epoxy
used in non-classified areas only. Globes and refractors thread finish, electrostatically applied for uniformity. All exposed
directly into ballast housing. hardware is stainless steel.
• Mounting hoods include cone-shaped pendant hood, standard • Hinge has high lip for added safety during installation
pendant, flexible pendant, ceiling and wall pendants (tapped and servicing. Hinge and bolt construction assures 360º
for 3/4” or 1” NPT), 25° angle stanchion, and 90° (straight) compression at all points on ballast housing gasket for positive
stanchion (both tapped for 1-1/4” or 1-1/2” NPT). sealing. Swing-away design of captive bolt and nut simplifies
• Cone hood fixtures for pendant mounting shed dust, dirt and servicing.
combustible fibers. Cone hood inhibits build-up that “insulates” • Body gaskets and globe gaskets are high-temperature silicone
fixture and slows heat transfer, and provides increased surface rubber.
area for more effective heat dissipation. • Capacitors are non-PCB type, thermally isolated from ballast.

† Tuff-skin is a registered trademark of Thomas Manufacturing Corp., Parkton, Maryland.


V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 941


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

• Mogul base porcelain socket with nickel-plated contacts has • Hot Restrike will restrike HPS lamp immediately when power is
392 °C/ 200 °C welded leads, prewired to the ballast. Assures restored after a momentary power interruption. Add suffix -R.
trouble-free operation in installations where high ambient • Smart Hot Restrike will immediately restrike HPS lamp when
temperatures are encountered. power is restored after a momentary power interruption. The
• HPS ballasts are High Power Factor (min. P.F. 90%). smart function removes the hot restrike ignitor from the circuit
Lighting

• A wide range of voltages available (120 to 600 Volt) and ballast if the lamp burns out or is removed from the socket. Eliminates
types (Reactor, CWA, CWI and Super CWA). starter failures caused by prolonged operation with cycling or
• All Mercmaster III mounting hoods have provision for easy field failing lamps. Add suffix -SR.
installation of fuses in fixtures (see fuse kit listings in this catalog • Smart Starter incorporates a 1-1/2-minute timer and performs
section). as a conventional starter to normally start lamp. Removes
• For electrical protection, a ground wire is provided on each itself from circuit if lamp burns out or is removed from socket.
Mercmaster to bond hood and ballast housing. Eliminates starter failures caused by prolonged operation with
• The AEx nA nR / Ex nR (V) factory sealed Mercmaster III cycling or failing lamps and simplifies finding their location,
Lighting: Enclosed and Gasketed — Area — HID

prevents vapors and gases from entering the globe chamber. reducing maintenance and repair costs. Available for all HPS
There are no seals or putty required which will reduce and PSMH fixtures. Add suffix -S.
installation time and installation errors. • Optional photocell for all fixtures except cone and ceiling mount
• The AEx nR Mercmaster III fixture requires all wiring entries to provides automatic “on-off” control.
be sealed. • Quartz Auxiliary comes to full brightness immediately and
remains lit until the HID lamp attains 60-70% of full illumination.
Standard Materials Quartz Auxiliary supplied with relay switch and socket to accept
• Mounting hoods, ballast bodies and guards: copperfree cast 120 V quartz double contact bayonet base lamp (not included).
aluminum (less than 4/10 of 1%) Add suffix -E to fixture catalog number. ‡
• Exposed hardware: stainless steel; latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach Certifications and Compliances
with strainless steel screws threading into stainless steel inserts. • UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
• Reflectors: Fiberglass reinforced white polyester 60079-15
• Globes: heat-resistant prismatic glass • UL Listed: E10444
• Refractors: heat-resistant prismatic glass
Related Products
Standard Finishes • Classified area photo controls are also available.
• Mounting hoods, ballast bodies, guards: epoxy powder coat
finish, electrostatically applied for complete, uniform surface
protection
• Reflectors: white polyester finish
Options
• AEx nA nR fixtures are available with a Class I, Zone 2 rating.
Add suffix -Z2.
• AEx nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -ZB.
• Ex nR fixtures, add suffix -Z V.
• Fuses can be field-installed on Mercmaster III fixtures. Kits
include fuse block, wire connectors and screws for attaching to
mounting hood. Fixtures with fuses do not comply with Marine
Type Electric Fixtures Outside Type (Salt Water) requirements
for marine listing. For fuse kits, see Electrical Specifications and
Fuse Kits page.

‡ Fixtures equipped with a quartz auxiliary lamp do not comply with UL requirements and are not suitable for use in classified locations.
V CSA Certification Only.

942 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Illustrated Features

Lighting
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for

Lighting: Enclosed and Gasketed — Area — HID


cooler operation. Quickly attach with
furnished stainless steel screws.
Ballast Assembly (Zone 2)
High Temperature Sockets Utilizing non-sparking components
Mogul base high-temperature porcelain Terminal Blocks (Zone 2) avoiding the ignition of gases or vapors
sockets. A seven-point terminal block is provided that may be present (nA).
to facilitate wiring. Terminal block
Aluminum Inner Reflector accommodates wire size ranging from #8 Mounting Hood and Globe Gaskets
Solid aluminum inner reflector (for to #24 AWG. Silicone rubber gasket seals out moisture,
refractor ballast housings only) improves dirt and dust. Stays flexible, withstands
photometric efficiency. Stainless Steel Inserts high temperatures. Closure design
Ballast bodies have stainless steel assures uniform gasket compression.
Globe Chamber (Zone 2) threaded inserts to receive stainless steel
Completely sealed from the ballast screws for reflectors and guard. Prevents Electrical Protection
housing and outside vapors/air (nA nR). "freezing”, allowing guards and reflectors Ground wire provided to bond mounting
to be easily removed and replaced at any hood to ballast housing.
time, without damage to the housing.

"Safety" High Epoxy Finish


Hinge Ballast housing, hoods and guards are
Extra-high hinge copperfree aluminum with epoxy powder
provides additional coat finish.
protection against
accidental Photocell
ballast housing Available for all fixtures except cone and
disengagement ceiling mount. Installs through knock-out
during installation in mounting hood. Provides continuous
or maintenance. ON-OFF dusk-to-dawn control.

Heat-Resistant Globes and Refractors


Stainless Steel Cooler Operating Cone Hood
Prismatic glass globes and refractors are
Latch Assembly Larger sloped surface sheds dusts, dirt
heat-resistant. They thread directly into the
Captive, stainless and combustible fibers providing better
ballast housing and seal against a high-
steel latch assembly heat dissipation.
temperature silicone rubber gasket.
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.

V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 943


© September 2010
Mercmaster™ III HID 50-250 Watt Emergency Luminaires Accessories and Options
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Quartz Emergency Light for Pulse Start Metal Halide or High Pressure Sodium Fixtures *
Mercmaster fixtures for or metal halide and high pressure sodium lamps can be supplied with a
socket to accept a 150 W or 250 W, 120 V quartz lamp. This D.C. bayonet base socket is in addition
to the standard lamp socket. In the event of a momentary power interruption, the quartz lamp is
automatically switched on. The single ended quartz lamp remains energized until the HID restrikes
Lighting

and reaches about 60% output.

The quartz emergency lamp socket is wired to a 120 V tap on the ballast and is therefore
independent of the lighting fixture voltage. No special field wiring is necessary.
Description Catalog Suffix
For fixture volts of 120, 208, 240 or 277 -MTE
Quartz Emergency Light
For fixture volts of 480 -48E
Quartz Emergency Light for
Lighting: Enclosed and Gasketed — Area — HID

QuartzPSMH
Emergencyor HPS
Light Fixtures
for Pulse Start Metal Halide or

HPS Smart Hot Restrike Accessory for HPS Fixtures


High Pressure Sodium Fixtures

Mercmaster fixtures for high pressure sodium lamps can be supplied with a special ignitor (starter
board). It instantly restrikes a hot high pressure sodium lamp when a momentary power interruption
occurs. This special ignitor, supplied in place of the standard ignitor, is a potted solid state device,
totally factory installed. It is not suitable for field installation.

The hot lamp restart option provides instant restart of 50, 70, 100 and 150 W HPS lamps after
power outages of up to 10 seconds. The lamps restrike instantly at almost full lumens. For power
interruptions of up to 30 seconds, the restart of the high pressure sodium lamp is also instant but
Smart
Hot at less than full lumens. The hot lamp restart accessory does not accelerate cold lamp start up or
Restrike
starting where the power outage is of a duration which has allowed the HPS lamp to cool.

Additional Advantages of the Smart Hot Restrike:


• Protects against self destruction in the event of failed, missing or broken lamps, or socket or
lead wire
Quartzfailure.
Emergency Light

HPS Smart Hot Restrike Accessory • Prevents “End of Life” lamps from continuous cycling over long periods of time.
• Remains unaffected by stray voltages, moderate overvoltages, as well as undervoltage
HPS Smart Hot Restrike Accessory for HPS Fixtures Quartz Emergency Light for Pulse Start Metal Halide or

for HPS Fixtures High Pressure Sodium Fixtures

conditions.
• Drops into the background during normal lamp operation with exceptionally low insertion loss.
• Fully encapsulated construction assures electrical integrity and mechanical vibration protection.
• UL recognized component.

Description Catalog Suffix


For fixture watts of 50, 70, 100 or 150 (HPS only) -SR
Accessory Options
 Guards: Guards are die-cast copperfree aluminum with baked epoxy finish to match fixtures.
Fixture supplied with stainless steel mounting screws which thread into stainless steel inserts on
fixture housing to attach guard. To order fixture with guard, add suffix -G to catalog number before
adding voltage suffix.
➋ Reflectors: Standard dome and 30° angle polyester reflectors are shown elsewhere in this
catalog section.
➌ Hot Restrike: Instantly restrikes a hot HPS lamp when power is restored after a momentary
outage. Available factory-installed only. To order, add suffix -R to catalog number.
➍ Quartz Emergency Light: When ordered, HPS fixtures will be supplied with a prewired special
DC bayonet base socket to accept a 150W, 120V quartz lamp (not furnished) that automatically
switches on when a power outage occurs. Fixtures ordered with this quartz emergency lamp feature
do NOT comply with requirements for classified areas and should be used only in non-classified
locations. To order, add suffix -E to catalog number and specify if a relay switch is desired.
➎ Photocell and Fuses: Photocontrol are available within the Lighting Section.
 Smart Starter: Performs as a conventional starter in lamp start-up. Removes itself from circuit at
end of lamp life or if lamp is out of socket. Add suffix -S to catalog number.
 Smart Hot Restrike (HPS only): Will immediately restrike HPS lamp when power is restored after
a momentary power interruption. The smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates starter failures caused by prolonged
operation with cycling or failing lamps. Add suffix -SR to catalog number.

*NOTE: Fixtures equipped with quartz emergency light do not comply with UL requirements and are not suitable for use in classified locations.
V CSA Certification Only.

944 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Order using catalog numbering guide below or select catalog number from tables on following pages.

Catalog Numbering Guide


KP A L 70 10 J5 G MT R Z2

Lighting
Series: Lamp Type: Hub Size: Guard Options: Options:
KP - L - High Pressure 75 - 3/4” NPT G - Guard E - Emergency Quartz
Mercmaster III Sodium 10 - 1” NPT Blank - No Guard F - Fuse Kit (Specify
250 H or P - Pulse Start 125 - 1-1/4” NPT Voltage)
Metal Halide ➊ stanchion R - Hot Restrike
150 - 1-1/2” NPT (50-150 W HPS
stanchion only)

Lighting: Enclosed and Gasketed — Area — HID


S - Smart Starter
SR - Smart Hot
Restrike
K - Kynar Coating
H1 - Photocontrol
120 V
H2 - Photocontrol
208 V
H3 - Photocontrol
240 V
H4 - Photocontrol
277 V
C - Safety Cable
Adapted V
E40 - Export Socket
D - E-40 Export
Socket V
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➌
Mounting Hood
Adapter V

Mounting: Wattage: Optical Assembly: Voltage: ➋ Suffix:


A - Pendant (rigid 10 - 100 W HPS, PSMH Blank - Glass Globe MT - 120/208/240/277, Z2 - Zone 2 suffix
mounting) 15 - 150 W HPS, PSMH J1 - NEMA I Glass 60 Hz (required for
C - Ceiling 17 - 175 W PSMH Refractor 5MT - 120/208/240/ AEx nA nR
CH - Pendant Cone Hood 20 - 200 W PSMH J3 - NEMA III Glass 277/480, 60 Hz rating)
F - Pendant (flexible 25 - 250 W PSMH Refractor 48 - 480, 60 Hz ZB - Zone 2 suffix
mounting) 50 - 50 W HPS J5 - NEMA V Glass 125 - 120, 50 Hz (required for
ST - 90° Stanchion (MT - Voltage Only) Refractor 225 - 225, 50 Hz AEx nR rating)
S - 25° Stanchion 70 - 70 W HPS, PSMH G3 - Large Glass Globe 226 - 220, 60 Hz Z - Zone 2 suffix
WB - Wall 17 - 175 W MH V 235 - 230, 50 Hz (required for
25 - 250 W MH V 245 - 240, 50 Hz Ex nR) V
C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V

Reflectors are ordered separately – see Accessories page.


➊ H - Lamp type is for 70W and 100W fixtures only.
P - Lamp type is for 175W, 200W and 250W fixtures only.
➋ Voltages shown are limited to specific combinations.
➌ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 945


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Temperature Identification Numbers of Mercmaster III fixtures.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Mercmaster III fixtures are listed for “Simultaneous Exposure” to combinations of Class I, Division 2 and Class II, Division 1 hazardous
conditions.
“T” Numbers for Mercmaster III Fixtures
Supply Simultaneous Exposure
Lighting

Lamp Wire Ambient Class I, Division 2 Class II, Division 1 Groups E, F and G ➊ Class I, Division2 / Class II, Division 1
Temp. Temp. Globe & G3 8” Globe & G3 8” Globe & G3 8”
Watts Type (°F/°C) (°F/°C) Globe Reflector Globe Refractor Globe Reflector Globe Refractor Globe Reflector Globe Refractor
194/90 104/40 T3C T3B — T3C T4A T4 — T6 T3A T3 — T3C
50 HPS 194/90 131/55 T3A T3A — T3A T4 T3B — T5 T3 T3 — T3A
194/90 149/65 T3A T3 — T3A T3C T3C — T4A T2D T2D — T3
194/90 104/40 T3B T3A — T3C T4 T3C — T6 T3 T3 — T3A
Lighting: Enclosed and Gasketed — Area — HID

70 HPS 194/90 131/55 T3A T3A — T3B T3C T3C — T5 T2D T2D — T3
194/90 149/65 T3 T3A — T3A T3C T3B — T4A T2C T2C — T3
194/90 104/40 T2D T2D T3 T3 — T3A (EF) T3 (EF) — — — — —
100 HPS 194/90 104/40 — — — — T3B — T4A T4A T2B T2B T2C T2C
194/90 131/55 T2D T2D T3 T3 — — T4 T4 — — T2B T2B
194/90 149/65 T2D T2D T2D T2D — — — — — — — —
194/90 104/40 T2B T2B — T2C — — — T3C T2 — — T2B
150 HPS 194/90 104/40 — — — — T3 (EF) — — — — — — —
194/90 131/55 T2B T2A — T2B — — — — — — — —
194/90 104/40 T3A T3A — T3A — — — T3C — — — —
70 PSMH 194/90 131/55 T3A T3A — T3A — — — T3C — — — —
194/90 149/65 T3 T2 — T3 — — — T3C — — — —
194/90 104/40 T3 T3 — T3 — — — T3C — — — T2B
100 PSMH 194/90 131/55 T3 T3 — T3 — — — T3C — — — T2A
194/90 149/65 T2D T2D — T2D — — — T3C — — — —
194/90 104/40 T2B T2B — T2B — — — T3C — — — T2B
150 PSMH 194/90 131/55 T2A T2A — T2B — — — T3C — — — T2A
257/125 149/65 T2A T2 — T2B — — — T3C — — — —
194/90 104/40 T2B T2B — T2B — — — T3C — — — T2B
175 PSMH 194/90 131/55 T2A T2A — T2B — — — T3C — — — T2A
221/105 149/65 T2A T2 — T2B — — — — — — — —
194/90 104/40 T2B T2B — T2B — — — T3B — — — —
200 PSMH
194/90 131/55 T2B T2B — T2B — — — — — — — —
194/90 104/40 T2 T2 — T2 — — — — — — — —
250 PSMH
194/90 131/55 T2 T2 — T2 — — — — — — — —
194/90 104/40 T2B T2B — T2B — — — T3C — — — —
175 MH V
194/90 131/55 T2A T2A — T2B — — — T3C — — — —
250 MH V 194/90 104/40 325 325 — T2 — — — T3B — — — —
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

➊ All Class II T Numbers are E, F, G unless otherwise indicated.


V CSA Certification Only.

946 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Thermal Performance
Class I, Zone 2, AEx nA nR IIC; Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Temperature Identification Numbers of Mercmaster III Fixtures.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Operating Temperatures: “T” Numbers for Zone 2 Mercmaster III Fixtures


The “T” number is established by separately determining the maximum temperature of the globe surface and ballast compartment. The hotter of the two is taken
to determine the “T” number for the overall fixture.
Supply
Lamp Class I, Zone 2 AEx nA nR IIC Class I, Zone 2 AEx nR IIC
Wire Ambient

Lighting
Temp. Temp. Globe & Refractor G3/Refractor Globe & Refractor G3/Refractor
Watts Type (°F/°C) (°F/°C) Globe Reflector Only & Reflector Globe Reflector Only & Reflector
194/90 104/40 T4 T4 T6 T4 T4 T4 T6 T4
50 HPS 194/90 131/55 T4 T3 T5 T3 T4 T3 T5 T3
194/90 149/65 T3 T3 T4 T3 T3 T3 T4 T3
194/90 104/40 T4 T4 T4 T4 T6 T5 T6 T4

Lighting: Enclosed and Gasketed — Area — HID


70 HPS 194/90 131/55 T4 T4 T4 T3 T5 T4 T5 T3
194/90 149/65 T4 T4 T3 T3 T4 T4 T5 T3
194/90 104/40 T4 T4 T4 T4 T5 T4 T6 T4
100 HPS 194/90 131/55 T4 T4 T3 T3 T4 T4 T5 T3
194/90 149/65 T4 T4 T3 T3 T4 T4 T4 T3
194/90 104/40 T4 T3 T3 T3 T4 T4 T5 T4
150 HPS 194/90 131/55 T3 T3 T3 T3 T4 T4 T4 T3
221/105 65 T3 T3 T3 T3 T4 T3 T4 T3
194/90 104/40 T4 T4 T4 — T5 T4 T6 —
70 PSMH 194/90 131/55 T3 T3 T3 — T4 T4 T5 —
194/90 149/65 T3 T3 T3 — T4 T3 T4 —
194/90 104/40 T3 T3 T3 — T5 T4 T6 —
100 PSMH 194/90 131/55 T3 T3 T3 — T4 T4 T5 —
194/90 149/65 T3 T3 T3 — T4 T3 T4 —
194/90 104/40 T4 T4 T4 — T4 T4 T5 —
150 PSMH 194/90 131/55 T3 T3 T3 — T4 T3 T4 —
221/105 149/65 T3 T3 T3 — T4 T3 T4 —
194/90 104/40 T3 T3 T4 — T3 T3 T4 —
175 PSMH 194/90 131/55 T3 T3 T3 — T3 T3 T4 —
221/105 149/65 T3 T3 T3 — T3 T3 T4 —
194/90 104/40 T3 T3 T4 — T3 T3 T4 —
200 PSMH 221/105 131/55 T3 T3 T3 — T3 T3 T4 —
221/105 149/65 T3 T3 T3 — T3 T3 T4 —
194/90 104/40 T3 T3 T3 — T3 T3 T3 —
250 PSMH
194/90 131/55 T3 T3 T3 — T3 T3 T3 —

“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR or AEx nR rating
“T” Number T1 T2 T3 T4 T5 T6

Temp. Range (°F) 547-842 394-572 277-392 214-275 187-212 185

Temp. Range (°C) 301-450 201-300 136-200 101-135 86-100 85

V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 947


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Classified Area Suitability
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Maximum Temperatures in °F/°C Obtained from Tests in a 104 °F/40 °C Ambient, Vertical Position, Lamp Base Up, as per NEC.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Fixture Selection Guide Indicates atmosphere for which fixture is suitable

 Denotes fixture with Globe Only. ➋ Denotes fixture with Globe and Reflector. ➌ Denotes fixture with 8” Refractor / G3 Globe
Minimum Fixture HPS (Watts) PSMH (Watts)
Lighting

Ignition “T” Number for


Class I, Division 2 Chemical °F/°C ➍ Chemical 50 70 100 150 70 100 175 200 250
Group A Atmospheres
acetylene 581/305 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➌ ➋
Group B Atmospheres
acrolein (inhibited) 428/220 T2D ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋
Lighting: Enclosed and Gasketed — Area — HID

arsine NA ➋
butadiene 788/420 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ethylene oxide 804/429 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
hydrogen 932/500 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
propylene oxide 840/449 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
propylnitrate 347/175 T3B ➋➌ ➋➌ ➋
Group C Atmospheres
acetaldehyde 347/175 T3B ➋➌ ➊ ➌ ➋
allyl alcohol 712/378 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
n-butyraldehyde 424/218 T2D ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋
carbon monoxide 1128/609 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
crotonaldehyde 450/232 T2C ➋➌ ➋➌ ➋➌ ➌ ➋ ➋➌ ➋
cyclopropane 928/498 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
diethyl ether (ethyl ether) 320/160 T3C  ➌ ➌ ➋
diethylamine 594/312 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➌ ➋
ethylene 842/450 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ethylenimine 608/320 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➌ ➋
ethly mercaptan 572/300 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➌ ➋
ethyl sulfide NA ➎
hydrogen cyanide 1000/538 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
hydrogen sulfide 500/260 T2B ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➋
morpholine 590/310 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➌ ➋
2-nitropropane 802/428 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
tetrahydrofuran 610/321 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➌ ➋
unsymmetrical dimethyl hydrazine 480/249 T2C ➋➌ ➋➌ ➋➌ ➌ ➋ ➋➌ ➋
Group D Atmospheres
acetic acid (glacial) 867/464 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
acetone 869/465 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
acrylonitrile 898/481 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ammonia 1204/651 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
benzene 928/498 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
butane 549/287 T2A ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➋
1-butanol (butyl alcohol) 649/343 325 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
➎ Not Available.
➏ A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
V CSA Certification Only.

948 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Classified Area Suitability
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Maximum Temperatures in °F/°C Obtained from Tests in a 104 °F/40 °C Ambient, Vertical Position, Lamp Base Up, as per NEC.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Fixture Selection Guide Indicates atmosphere for which fixture is suitable


 Denotes fixture with Globe Only. ➋ Denotes fixture with Globe and Reflector. ➌ Denotes fixture with 8” Refractor / G3 Globe

Minimum Fixture HPS (Watts) PSMH (Watts)

Lighting
Ignition “T” Number for
Class I, Division 2 Chemical °F/°C ➍ Chemical 50 70 100 150 70 100 175 200 250
Group D Atmospheres
2-butanol (secondary butyl alcohol) 761/405 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
n-butyl acetate 797/425 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
isobutyl acetate 790/421 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋

Lighting: Enclosed and Gasketed — Area — HID


sec-butyl alcohol 649/343 325 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
di-isobutylene 736/391 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ethane 882/472 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ethanol (ethyl alcohol) 685/363 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ethyl acetate 799/426 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ethylene diamine (anhydrous) 725/385 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
ethylene dichloride 775/413 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
gasoline (56-60 octane) 536/280 T2A ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➋
heptanes 399/204 T3 ➋➌ ➋➌ ➋➌ ➋ ➋➌
hexanes 433/223 T2D ➋➌ ➋➌  ➋ ➋➌
isoprene 743/395 350 ➋➌ ➋➌  ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
isopropyl ether 829/443 350 ➋➌ ➋➌  ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
mesityl oxide 651/344 325 ➋➌ ➋➌  ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
methane (natural gas) 999/537 T1 ➋➌ ➋➌  ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
methanol (methyl alcohol) 725/385 350 ➋➌ ➋➌  ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
3-methyl-l-butanol (isoamyl alcohol) 662/350 350 ➋➌ ➋➌ ➋ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
methyl ethyl ketone 759/404 350 ➋➌ ➋➌ ➋ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
methyl isobutyl ketone 838/448 350 ➋➌ ➋➌ ➋ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
2-methyl-1-propanol (isobutyl alcohol) 779/415 350 ➋➌ ➋➌ ➋ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
2-methyl-1-propanol (tertiary butyl alcohol) 892/478 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
petroleum naphtha ➏ 550/288 T2A ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➋
pyridine 900/482 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
octanes 403/206 T3 ➋➌ ➋➌ ➋➌ ➋ ➋➌
pentanes 500/260 T2B ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➋
1-pentanol (amyl alcohol) 572/300 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌   ➋
propane 810/432 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
1-propanol (propyl alcohol) 774/412 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
2-propanol (isopropyl alcohol) 750/399 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌  ➋
propylene 851/455 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
styrene 914/490 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
toluene 896/480 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
vinyl acetate 756/402 350 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
vinyl chloride 882/472 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
xylenes (o-xylene) 865/463 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋ ➋➌ ➋➌ ➋➌ ➋
This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
➎ Not Available.
➏ A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 949


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Classified Area Suitability
Class I, Zone 2, AEx nA nR IIC; Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Maximum Temperatures in ºF/ºC Obtained from Tests in a 104 ºF/40 ºC Ambient, Vertical Position, Lamp Base Up.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Fixture Selection Guide Indicates atmosphere for which fixture is suitable

➋ Denotes fixture with Globe and Reflector. ➌ Denotes fixture with 8” Refractor.

Minimum Fixture HPS (Watts) PSMH (Watts)


Lighting

Ignition “T” Number for


Class I, Division 2 Chemical °F/°C ➍ Chemical 50 70 100 150 70 100 175 200 250
Group IIC
acetylene 581/305 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
acetylene 572/300 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
hydrogen 932/500 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
Lighting: Enclosed and Gasketed — Area — HID

Group IIB
ethylene 914/490 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
butadiene 1.3 797/425 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
carbon monoxide coke oven gas 1040/560 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
diethyl ether (ethyl ether) 320/160 T4 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
ethylene 842/450 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
ethylenimine ethylene oxide 797/425 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
Group IIA
acetone 869/465 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
amyl acetate 707/375 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
ammonia 1204/651 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
benzene 928/498 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
butane 549/287 T3 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
1-butanol (butyl alcohol) 649/343 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
n-butyl acetate cyclohexane 500/260 T3 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
ethyl methyl ketone 959/515 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
ethanol (ethyl alcohol) 685/363 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
ethyl acetate 799/426 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
heptanes 399/204 T3 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
hexanes 433/223 T3 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
isoprene isobutanol 806/430 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
mesityl oxide methyl acetate 932/500 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
methanol (methyl alcohol) 725/385 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
n-propyl acetate 932/500 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
n-butul acetate 788/420 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
pentanes 500/260 T3 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
propane 810/432 T2 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌
xylenes (o-xylene) 865/463 T1 ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌ ➋➌

This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
V CSA Certification Only.

950 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
50 W, 70 W, 100 W, 150 W HPS
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Catalog Numbers ➌➍➎


Hub Size with Type V 8” Refractor
Lamp Type Lamp Watts (Inches) with Globe or G3 Globe ➋
Pendant — One Hub, Rigid Mounting ➊

Lighting
3/4 KPAL5075 KPAL5075J5
HPS 50
1 KPAL5010 KPAL5010J5
3/4 KPAL7075 KPAL7075J5
HPS 70
1 KPAL7010 KPAL7010J5
3/4 KPAL1075 KPAL1075J5
HPS 100
1 KPAL1010 KPAL1010J5

Lighting: Enclosed and Gasketed — Area — HID


3/4 KPAL1575 KPAL1575J5
HPS 150
1 KPAL1510 KPAL1510J5
Pendant Cone — One Hub, Rigid Mounting
3/4 KPCHL5075 KPCHL5075J5
HPS 50
1 KPCHL5010 KPCHL5010J5
3/4 KPCHL7075 KPCHL7075J5
HPS 70
1 KPCHL7010 KPCHL7010J5
3/4 KPCHL1075 KPCHL1075J5
HPS 100
1 KPCHL1010 KPCHL1010J5
3/4 KPCHL1575 KPCHL1575J5
HPS 150
1 KPCHL1510 KPCHL1510J5
Ceiling — Five Hubs, Four Close-Up Plugs
3/4 KPCL5075 KPCL5075J5
HPS 50
1 KPCL5010 KPCL5010J5
3/4 KPCL7075 KPCL7075J5
HPS 70
1 KPCL7010 KPCL7010J5
3/4 KPCL1075 KPCL1075J5
HPS 100
1 KPCL1010 KPCL1010J5
3/4 KPCL1575 KPCL1575J5
HPS 150
1 KPCL1510 KPCL1510J5

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 50 X — — — X X — X — — — — X
HPS 70 X — X X X X — X — — — — X
HPS 100 X — X X X X — X — — X X X
HPS 150 X — X X X X — X — — X X X
PSMH 70 X — X X X — — X — — — — X
PSMH 100 X — X X X — — X — — — — X
PSMH 150 X — X X X — — X — — — — X
PSMH 175 X X X — — — — — — — — — X
PSMH 200 X — X — — — — — — — — — X
PSMH 250 X — — — — — — — — — — — X
MH V 175 X — — X X — — X X X X X X
MH V 250 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 951


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
50 W, 70 W, 100 W, 150 W HPS
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Catalog Numbers ➌➍➎


Hub Size with Type V 8” Refractor
Lamp Type Lamp Watts (Inches) with Globe or G3 Globe ➋
Wall — Five Hubs, Four Close-Up Plugs
Lighting

3/4 KPWBL5075 KPWBL5075J5


HPS 50
1 KPWBL5010 KPWBL5010J5
3/4 KPWBL7075 KPWBL7075J5
HPS 70
1 KPWBL7010 KPWBL7010J5
3/4 KPWBL1075 KPWBL1075J5
HPS 100
1 KPWBL1010 KPWBL1010J5
Lighting: Enclosed and Gasketed — Area — HID

3/4 KPWBL1575 KPWBL1575J5


HPS 150
1 KPWBL1510 KPWBL1510J5
25° Stanchion — One Hub
1-1/4 KPSL50125 KPSL50125J5
HPS 50
1-1/2 KPSL50150 KPSL50150J5
1-1/4 KPSL70125 KPSL70125J5
HPS 70
1-1/2 KPSL70150 KPSL70150J5
1-1/4 KPSL10125 KPSL10125J5
HPS 100
1-1/2 KPSL10150 KPSL10150J5
1-1/4 KPSL15125 KPSL15125J5
HPS 150
1-1/2 KPSL15150 KPSL15150J5
90° Stanchion — One Hub
1-1/4 KPSTL50125 KPSTL50125J5
HPS 50
1-1/2 KPSTL50150 KPSTL50150J5
1-1/4 KPSTL70125 KPSTL70125J5
HPS 70
1-1/2 KPSTL70150 KPSTL70150J5
1-1/4 KPSTL10125 KPSTL10125J5
HPS 100
1-1/2 KPSTL10150 KPSTL10150J5
1-1/4 KPSTL15125 KPSTL15125J5
HPS 150
1-1/2 KPSTL15150 KPSTL15150J5

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 50 X — — — X X — X — — — — X
HPS 70 X — X X X X — X — — — — X
HPS 100 X — X X X X — X — — X X X
HPS 150 X — X X X X — X — — X X X
PSMH 70 X — X X X — — X — — — — X
PSMH 100 X — X X X — — X — — — — X
PSMH 150 X — X X X — — X — — — — X
PSMH 175 X X X — — — — — — — — — X
PSMH 200 X — X — — — — — — — — — X
PSMH 250 X — — — — — — — — — — — X
MH V 175 X — — X X — — X X X X X X
MH V 250 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

952 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt
70 W, 100 W, 150 W, 175 W, 200 W, 250 W PSMH
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎


Lamp Type Lamp Watts (Inches) with Globe with Type V 8” Refractor ➋
Pendant — One Hub, Rigid Mounting ➊
3/4 KPAH7075 KPAH7075J5
PSMH 70
1 KPAH7010 KPAH7010J5

Lighting
3/4 KPAH1075 KPAH1075J5
PSMH 100
1 KPAH1010 KPAH1010J5
3/4 KPAP1575 KPAP1575J5
PSMH 150
1 KPAP1510 KPAP1510J5
3/4 KPAP1775 KPAP1775J5
PSMH 175
1 KPAP1710 KPAP1710J5
3/4 KPAP2075 KPAP2075J5
PSMH 200
1 KPAP2010 KPAP2010J5

Lighting: Enclosed and Gasketed — Area — HID


3/4 KPAP2575 KPAP2575J5
PSMH 250 ➏
1 KPAP2510 KPAP2510J5
Pendant Cone — One Hub, Rigid Mounting
3/4 KPCHH7075 KPCHH7075J5
PSMH 70
1 KPCHH7010 KPCHH7010J5
3/4 KPCHH1075 KPCHH1075J5
PSMH 100
1 KPCHH1010 KPCHH1010J5
3/4 KPCHP1575 KPCHP1575J5
PSMH 150
1 KPCHP1510 KPCHP1510J5
3/4 KPCHP1775 KPCHP1775J5
PSMH 175
1 KPCHP1710 KPCHP1710J5
3/4 KPCHP2075 KPCHP2075J5
PSMH 200
1 KPCHP2010 KPCHP2010J5
3/4 KPCHP2575 KPCHP2575J5
PSMH 250 ➏
1 KPCHP2510 KPCHP2510J5
Ceiling — Five Hubs, Four Close-Up Plugs
3/4 KPCH7075 KPCH7075J5
PSMH 70
1 KPCH7075 KPCH7010J5
3/4 KPCH1075 KPCH1075J5
PSMH 100
1 KPCH1010 KPCH1010J5
3/4 KPCP1575 KPCP1575J5
PSMH 150
1 KPCP1510 KPCP1510J5
3/4 KPCP1775 KPCP1775J5
PSMH 175
1 KPCP1710 KPCP1710J5
3/4 KPCP2075 KPCP2075J5
PSMH 200
1 KPCP2010 KPCP2010J5
3/4 KPCP2575 KPCP2575J5
PSMH 250 ➏
1 KPCP2510 KPCP2510J5
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 50 X — — — X X — X — — — — X
HPS 70 X — X X X X — X — — — — X
HPS 100 X — X X X X — X — — X X X
HPS 150 X — X X X X — X — — X X X
PSMH 70 X — X X X — — X — — — — X
PSMH 100 X — X X X — — X — — — — X
PSMH 150 X — X X X — — X — — — — X
PSMH 175 X X X — — — — — — — — — X
PSMH 200 X — X — — — — — — — — — X
PSMH 250 X — — — — — — — — — — — X
MH V 175 X — — X X — — X X X X X X
MH V 250 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 953


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
70 W, 100 W, 150 W, 175 W, 200 W, 250 W PSMH
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎


Lamp Type Lamp Watts (Inches) with Globe with Type V 8” Refractor ➋
Wall — Five Hubs, Four Close-Up Plugs
3/4 KPWBH7075 KPWBH7075J5
PSMH 70
1 KPWBH7010 KPWBH7010J5
Lighting

3/4 KPWBH1075 KPWBH1075J5


PSMH 100
1 KPWBH1010 KPWBH1010J5
3/4 KPWBP1575 KPWBP1575J5
PSMH 150
1 KPWBP1510 KPWBP1510J5
3/4 KPWBP1775 KPWBP1775J5
PSMH 175
1 KPWBP1710 KPWBP1710J5
3/4 KPWBP2075 KPWBP2075J5
PSMH 200
1 KPWBP2010 KPWBP2010J5
Lighting: Enclosed and Gasketed — Area — HID

3/4 KPWBP2575 KPWBP2575J5


PSMH 250 ➏ 1 KPWBP2510 KPWBP2510J5
25° Stanchion — One Hub
1-1/4 KPSH70125 KPSH70125J5
PSMH 70
1-1/2 KPSH70150 KPSH70150J5
1-1/4 KPSH10125 KPSH10125J5
PSMH 100
1-1/2 KPSH10150 KPSH10150J5
1-1/4 KPSP15125 KPSP15125J5
PSMH 150
1-1/2 KPSP15150 KPSP15150J5
1-1/4 KPSP17125 KPSP17125J5
PSMH 175
1-1/2 KPSP17150 KPSP17150J5
1-1/4 KPSP20125 KPSP20125J5
PSMH 200
1-1/2 KPSP20150 KPSP20150J5
1-1/4 KPSP25125 KPSP25125J5
PSMH 250 ➏
1-1/2 KPSP25150 KPSP25150J5
90° Stanchion — One Hub
1-1/4 KPSTH70125 KPSTH70125J5
PSMH 70
1-1/2 KPSTH70150 KPSTH70150J5
1-1/4 KPSTH10125 KPSTH10125J5
PSMH 100
1-1/2 KPSTH10150 KPSTH10150J5
1-1/4 KPSTP15125 KPSTP15125J5
PSMH 150
1-1/2 KPSTP15150 KPSTP15150J5
1-1/4 KPSTP17125 KPSTP17125J5
PSMH 175
1-1/2 KPSTP17150 KPSTP17150J5
1-1/4 KPSTP20125 KPSTP20125J5
PSMH 200
1-1/2 KPSTP20150 KPSTP20150J5
Shown with Globe and Optional Guard
1-1/4 KPSTP25125 KPSTP25125J5
PSMH 250 ➏
1-1/2 KPSTP25150 KPSTP25150J5
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 50 X — — — X X — X — — — — X
HPS 70 X — X X X X — X — — — — X
HPS 100 X — X X X X — X — — X X X
HPS 150 X — X X X X — X — — X X X
PSMH 70 X — X X X — — X — — — — X
PSMH 100 X — X X X — — X — — — — X
PSMH 150 X — X X X — — X — — — — X
PSMH 175 X X X — — — — — — — — — X
PSMH 200 X — X — — — — — — — — — X
PSMH 250 X — — — — — — — — — — — X
MH V 175 X — — X X — — X X X X X X
MH V 250 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

954 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt
175 W, 250 W MH V
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎


Lamp Type Lamp Watts (Inches) with Globe with Type V 8” Refractor ➋
Pendant — One Hub, Rigid Mounting ➊

Lighting
3/4 KPAH1775 KPAH1775J5
MH V 175
1 KPAH1710 KPAH1710J5
3/4 KPAH2575 KPAH2575J5
MH V 250 ➏
1 KPAH2510 KPAH2510J5

Lighting: Enclosed and Gasketed — Area — HID


Pendant Cone — One Hub, Rigid Mounting

3/4 KPCHH1775 KPCHH1775J5


MH V 175
1 KPCHH1710 KPCHH1710J5
3/4 KPCHH2575 KPCHH2575J5
MH V 250 ➏
1 KPCHH2510 KPCHH2510J5

Ceiling — Five Hubs, Four Close-Up Plugs

3/4 KPCH1775 KPCH1775J5


MH V 175
1 KPCH1710 KPCH1710J5
3/4 KPCH2575 KPCH2575J5
MH V 250 ➏
1 KPCH2510 KPCH2510J5

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 50 X — — — X X — X — — — — X
HPS 70 X — X X X X — X — — — — X
HPS 100 X — X X X X — X — — X X X
HPS 150 X — X X X X — X — — X X X
PSMH 70 X — X X X — — X — — — — X
PSMH 100 X — X X X — — X — — — — X
PSMH 150 X — X X X — — X — — — — X
PSMH 175 X X X — — — — — — — — — X
PSMH 200 X — X — — — — — — — — — X
PSMH 250 X — — — — — — — — — — — X
MH V 175 X — — X X — — X X X X X X
MH V 250 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 955


© September 2010
Mercmaster™ III HID 50-250 Watt
175 W, 250 W MH V
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Hub Size Catalog Numbers ➌➍➎


Lamp Type Lamp Watts (Inches) with Globe with Type V 8” Refractor ➋
Wall — Five Hubs, Four Close-Up Plugs
Lighting

3/4 KPWBH1775 KPWBH1775J5


MH V 175
1 KPWBH1710 KPWBH1710J5
3/4 KPWBH2575 KPWBH2575J5
MH V 250 ➏
1 KPWBH2510 KPWBH2510J5
Lighting: Enclosed and Gasketed — Area — HID

25° Stanchion — One Hub

1-1/4 KPSH17125 KPSH17125J5


MH V 175
1-1/2 KPSH17150 KPSH17150J5
1-1/4 KPSH25125 KPSH25125J5
MH V 250 ➏
1-1/2 KPSH25150 KPSH25150J5

90° Stanchion — One Hub

1-1/4 KPSTH17125 KPSTH17125J5


MH V 175
1-1/2 KPSTH17150 KPSTH17150J5
1-1/4 KPSTH25125 KPSTH25125J5
MH V 250 ➏
1-1/2 KPSTH25150 KPSTH25150J5

Shown with Globe and Optional Guard

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).


➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 50 X — — — X X — X — — — — X
HPS 70 X — X X X X — X — — — — X
HPS 100 X — X X X X — X — — X X X
HPS 150 X — X X X X — X — — X X X
PSMH 70 X — X X X — — X — — — — X
PSMH 100 X — X X X — — X — — — — X
PSMH 150 X — X X X — — X — — — — X
PSMH 175 X X X — — — — — — — — — X
PSMH 200 X — X — — — — — — — — — X
PSMH 250 X — — — — — — — — — — — X
MH V 175 X — — X X — — X X X X X X
MH V 250 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

956 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt PRE-PAK™ Luminaires
Factory-Assembled Fixtures
For 70 W, 100 W or 150 W High Pressure Sodium Lamps, or 100 W or 175 W Pulse Start Metal Halide Lamps. Mogul Base Lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

These pre-packaged fixture component combinations are delivered fully assembled and packed in a single carton. They are available with
or without lamp, and with choice of globe or NEMA Type I, III or V refractors – all with or without guards. PRE-PAK units simplify ordering,
stocking and shipping, and result in savings on job-site assembly and installation time and costs.

Catalog numbers do not include mounting hood or reflector. For mounting hood and reflectors selection, see below and order

Lighting
separately. Hood and Reflector will be packaged separately.

Lighting: Enclosed and Gasketed — Area — HID


PRE-PAK Fixtures ➊➍
Lamp Type Ballast Assembly Ballast Assembly Ballast Assembly Ballast Assembly Ballast Assembly
and Watts with Globe Only with Globe and Guard with G3 Globe Only with Refractor Only ➌ with Refractor and Guard
100 W PSMH ➋ KPBU100H-MT KPBU100HG-MT — KPBU100HJ5-MT KPBU100HJ5G-MT
175 W PSMH KPBU175P-MT KPBU175PG-MT — KPBU175PJ5-MT KPBU175PJ5G-MT
70 W HPS KPBU70L-MT KPBU70LG-MT — KPBU70LJ5-MT KPBU70LJ5G-MT
100 W HPS KPBU100L-MT KPBU100LG-MT KPBUG3100L-MT KPBU100LJ5-MT KPBU100LJ5G-MT
150 W HPS KPBU150L-MT KPBU150LG-MT — KPBU150LJ5-MT KPBU150LJ5G-MT
175 W MH V KPBU175H-TT KPBU175HG-TT — KPBU175HJ5-TT KPBU175HJ5G-TT
250 W MH V KPBU250H-TT KPBU250HG-TT — KPBU250HJ5-TT KPBU250HJ5G-TT

White Polyester Reflectors


Mounting Hoods Furnished with stainless steel screws
Hub Size Catalog Catalog
Description (Inches) Number Description Number
Pendant 3/4 KPA-75
One Hub, Rigid Mounting Standard Dome
1 KPA-100 KR2-ST
For Globe Fixtures
Pendant — Flexible 3/4 KPAF-75
One Hub, Flexible Mounting 1 KPAF-100
3/4 KPCH-75 30° Angle
Pendant Cone KR2-AN
For Globe Fixtures
One Hub, Rigid 1 KPCH-100
Ceiling 3/4 KPC-75
Five Hubs, Standard Dome
Four Close-Up Plugs 1 KPC-100 CMR-4ST
For Glass Refractor Fixtures
Wall 3/4 KPWB-75
Five Hubs,
Four Close-Up Plugs 1 KPWB-100
1-1/4 KPS-125 30° Angle
25° Stanchion CMR-4AN
For Glass Refractor Fixtures
One Hub 1-1/2 KPS-150

1-1/4 KPST-125
90° Stanchion
One Hub 1-1/2 KPST-150

➊ All catalog numbers above are fixtures without lamp. To order fixture complete with appropriate installed lamp, add suffix L to catalog number. All PRE-PAK fixtures
include multi-tap ballast for operation on 120 V, 208 V, 240 V or 277 V lines. Fixture component combinations listed are furnished completely assembled in a single
carton.
➋ 100 W fixtures use ED-28 mogul base lamps.
➌ Refractor catalog numbers listed are for NEMA Type V. To order fixture with Type III refractor, change J5 in catalog number to J3; for Type I refractor, change
J5 to J1.
➍ For CSA 120/277/347 Vac tri-tap ballast, change -MT to -TT V.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 957


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Mounting Hoods
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Mounting Hoods
Description Hub Size (Inches) Catalog Number
Pendant
3/4 KPA-75
Lighting

One Hub, Rigid Mounting


1 KPA-100

Pendant — Flexible
3/4 KPAF-75
One Hub, Flexible Mounting
1 KPAF-100
Lighting: Enclosed and Gasketed — Area — HID

Pendant Cone
3/4 KPCH-75
One Hub, Rigid
1 KPCH-100

Ceiling
3/4 KPC-75
Five Hubs, Four Close-Up Plugs
1 KPC-100

Wall
3/4 KPWB-75
Five Hubs, Four Close-Up Plugs
1 KPWB-100

25° Stanchion
1-1/4 KPS-125

One Hub
1-1/2 KPS-150

90° Stanchion
1-1/4 KPST-125

One Hub
1-1/2 KPST-150

958 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Ballast Bodies

Lighting
Ballast Body for Glass Globe (shown) Ballast Body for Glass Refractor or G3 Globe (shown)
High Pressure Sodium Pulse Start Metal Halide
High Power Factor (Min. P.F. 90%) Super Constant Wattage Autotransformer (Min. P.F. 90%)

Catalog Number ➋➍➎➏ Voltage Suffixes


Lamp Lamp For G3 Globe ➊/
Type Watts For Globe Refractor MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V

Lighting: Enclosed and Gasketed — Area — HID


HPS 50 ➌ KPB50L KPBR50L X — — — X X — X — — — — X
HPS 70 ➌ KPB70L KPBR70L X — X X X X — X — — — — X
HPS 100 ➌ KPB100L KPBR100L X — X X X X — X — — X X X
HPS 150 ➌ KPB150L KPBR150L X — X X X X — X — — X X X
PSMH 70 KPB70H KPBR70H X — X X X — — X — — — — X
PSMH 100 KPB100H KPBR100H X — X X X — — X — — — — X
PSMH 150 KPB150P KPBR150P X — X X X — — X — — — — X
PSMH 175 KPB175P KPBR175P X X X — — — — — — — — — X
PSMH 200 KPB200P KPBR200P X — X — — — — — — — — — X
PSMH 250 KPBG250P KPBR250P X — — — — — — — — — — — X
MH V 175 KPB175H KPBR175H X — — X X — — X X X X X X
MH V 250 KPB250H KPBR250H X — — X X — — X X X X X X
Voltages:
LB - Incandescent, 120 V 60 Hz 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V

➊ For HPS version fixtures only.


➋ After voltage suffix add: -S for Smart Starter.
➌ After voltage suffix add: -SR for Smart Hot Restrike, -R for ballast body with Hot Restrike Ignitor.
➍ Add -E after voltage suffix for ballast body with provision for Quartz Emergency Light. Not suitable for hazardous locations.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 959


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Optics
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Description Catalog Number


Prismatic Glass Globes — Heat-Resistant
Clear VPGL-2HR
For use in areas where fixture is subject to
Lighting

extreme thermal shock Amber VPGL-2AM


Heat-Resistant
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE
Glass Globe
Clear VPGL3HR
Lighting: Enclosed and Gasketed — Area — HID

G3 Glass Globe

Tuff-Skin® Coated Prismatic Glass Globes — For Non-Classified Areas


Clear VPGL-2HRT
For use in areas where fixture is subject to
extreme thermal shock
Heat-Resistant

Tuff-Skin® Glass Globe

Polycarbonate Globes — Impact-Resistant ➊


Clear VPGL-2PL

Use 100 watt lamp max. Do not use in Amber VPGL-2AMPL


ambients exceeding 77 ºF/25 ºC. Green VPGL-2GRPL
Red VPGL-2REPL

Polycarbonate Globe

➊ Polycarbonate globes are shatter-resistant – for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ideally
suited for areas where vandalism, high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 77 °F/25 °C. For burning in
vertical base-up positions only.

960 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Optics
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Light Distribution IES/NEMA Distribution Curves Catalog Number


Closed Prismatic Glass Refractors — Heat-Resistant

Lighting
NEMA Type I LPG-R1

NEMA Type III LPG-R3

Glass Refractor

Lighting: Enclosed and Gasketed — Area — HID


NEMA Type V LPG-R5

Closed Prismatic Polymeric Refractors


For use with PSMH lamps, 100 W max. 104 °F/40 °C max. ambient temperature.
Suitable for Class II, Division 1 and 2, Groups F, G; NEMA 4X, UL 1598A Marine Type Electric Fixtures Outside Type (Salt Water)

NEMA Type II LPRF-2CP

NEMA Type III LPRF-3CP

NEMA Type IV LPRF-4CP


Polymeric Refractor

NEMA Type V LPRF-5CP

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 961


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Accessories and Replacement Parts
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Item Description Catalog Number


White Polyester Reflectors — Furnished with stainless steel screws
For Globe Fixtures Standard Dome KR2-ST
Lighting

Deep Dome KR2-DD ➊


30° Angle KR2-AN
For Glass Refractor Fixtures ➋ Standard Dome CMR-4ST
Deep Dome CMR-4DD ➊
30° Angle CMR-4AN
Lighting: Enclosed and Gasketed — Area — HID

Standard Dome 30° Angle

Guards
Globe Guard KGU2

G3 Globe/Refractor
KRG2
Guard

Globe Guard Refractor Guard

Replacement Globe Gaskets — Silicone Rubber


Globe Gasket VPGL-GK

G3 Globe/Refractor
KRF-GK
Gasket

Globe Gaskets

Retrofit Pendant Mounting Adapter

Permits use of Mercmaster III pendant hood


with 3/4” hub on existing V-51 mounting LPAD-1
hood.

Mounting Adapter

➊ Dark Skies Compliant.


➋ Fixtures with refractors are not UL Listed when used with reflectors.

962 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Ballast Weights and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Ballast Housing Weights Fuse Kits


Fuse Kit Catalog Number
HPS PSMH Lamp Fuse Quantity
Lamp Watts (Wt. Lbs/Kg ➊➋) (Wt. Lbs/Kg ➊➋) Watts Volts Required HPS PSMH
Globe Housing with Ballast 120 1 F5 —

Lighting
50 12.5/5.7 — 208 2 F3 —
70 15/6.8 15.25/6.9 50 240 2 F3 —
100 16/7.3 16.25/7.4 277 1 F2 —
150 17/7.7 16.75/7.6 347 V 1 F1 F1
175 — 17.25/7.8 120 1 F5 F4
200 — 18/8.2 208 2 F3 F3

Lighting: Enclosed and Gasketed — Area — HID


250 — 18.5/8.4 240 2 F3 F3
70
Refractor Housing with Ballast 277 1 F2 F2
50 13/5.9 — 347 V 1 F1 F2
70 15.5/7.0 15.75/7.1 480 2 F2 F1
100 16.5/7.5 16.75/7.6 120 1 F8 F6
150 17.5/7.9 17.25/7.8 208 2 F5 F4
175 — 17.75/8.1 240 2 F5 F3
100
200 — 18.5/8.4 277 1 F3 F3
250 — 19/8.6 347 V 1 F1 F2
480 2 F3 F2
120 1 F10 —
Component and Accessory Weights 208 2 F5 —
Item Wt. Lbs/Kg ➊ 240 2 F5 —
150
Mounting Hoods 277 1 F5 —
Pendant 2.25/1.0 347 V 1 F2 F2
Pendant Cone 2.5/1.1 480 2 F3 —
Ceiling 3/1.4 120 1 — F5
Wall 4/1.8 208 2 — F3
25° Stanchion 3.25/1.5 240 2 — F3
175
Straight Stanchion 3.75/1.7 277 1 — F2
Refractors, Globes and Guards 347 V 1 F2 F2
8” Glass Refractor/G3 Globe 5.25/2.4 480 2 — F2
Glass Globe 3.75/1.7 120 1 — F9
Globe Guard 1/0.5 208 2 — F6
Refractor Guard 1/0.5 240 2 — F5
200
Reflectors 277 1 — F4
Standard Dome 2.50/1.1 347 V 1 — F2
30° Angle 2.50/1.1 480 2 — F2
120 1 — F8
208 2 — F5
250 240 2 — F5
277 1 — F3
347 V 1 F3 F3

➊ Weights are approximate.


➋ Add 1 lbs/0.5 kg for HPS fixtures with Hot Restrike. Add 0.25 lbs/0.1 kg for Quartz Emergency Light.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 963


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Electrical Specifications
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Electrical Specifications
Line Type of Starting Operating Total Line Type of Starting Operating Total
Voltage Ballast ➊ Amps Amps Watts Voltage Ballast ➊ Amps Amps Watts
50 Watt High Pressure Sodium 150 Watt Pulse Start Metal Halide
Lighting

120 HX-HPF 0.58 0.58 64 120 HX-HPF 1.75 1.60 188


208 HX-HPF 0.35 0.33 64 208 HX-HPF 1.30 1.00 188
240 HX-HPF 0.31 0.29 64 240 HX-HPF 0.85 0.80 188
277 HX-HPF 0.25 0.25 64 277 HX-HPF 0.77 0.70 188
347 V HX-HPF 0.26 0.21 68 347 V Super C.W.A. 0.65 0.55 185
70 Watt High Pressure Sodium 480 Super C.W.A. 0.45 0.42 185
120 HX-HPF 0.90 0.82 94 175 Watt Pulse Start Metal Halide
Lighting: Enclosed and Gasketed — Area — HID

208 HX-HPF 0.50 0.48 94 120 Super C.W.A. 0.90 1.78 199
240 HX-HPF 0.44 0.41 94 208 Super C.W.A. 0.50 1.08 199
277 HX-HPF 0.35 0.36 94 240 Super C.W.A. 0.35 0.89 199
347 V HX-HPF 0.30 0.30 94 277 Super C.W.A. 0.30 0.76 199
480 HX-HPF 0.21 0.21 94 347 V Super C.W.A. 0.25 0.65 208
100 Watt High Pressure Sodium 480 Super C.W.A. 0.25 0.50 213
120 HX-HPF 1.30 1.15 130 175 Watt Metal Halide V
208 HX-HPF 0.76 0.67 130 120 C.W.A. 1.30 1.80 210
240 HX-HPF 0.66 0.60 130 208 C.W.A. 0.75 1.04 210
277 HX-HPF 0.60 0.52 130 240 C.W.A. 0.65 0.90 210
347 V HX-HPF 0.45 0.39 130 277 C.W.A. 0.55 0.80 210
480 HX-HPF 0.33 0.31 135 347 C.W.A. 0.50 0.65 210
480 C.W.I. 0.17 0.30 130 480 C.W.I. 0.20 0.45 215
600 C.W.I. 0.14 0.24 130 600 C.W.I. 0.16 0.37 215
150 Watt High Pressure Sodium ➋ 175 Watt Metal Halide V
120 HX-HPF 2.00 1.70 188 120 Super C.W.A. 1.30 1.80 213
208 HX-HPF 1.15 0.95 188 208 Super C.W.A. 0.75 1.10 213
240 HX-HPF 1.00 0.85 188 240 Super C.W.A. 0.65 0.90 213
277 HX-HPF 0.85 0.72 188 277 Super C.W.A. 0.55 0.80 213
347 V HX-HPF 0.52 0.56 188 480 Super C.W.A. 0.35 0.45 213
480 HX-HPF 0.50 0.47 189 250 Watt Metal Halide V
480 C.W.I. 0.25 0.42 190 120 Super C.W.A. 1.20 2.60 298
600 C.W.I. 0.19 0.35 190 208 Super C.W.A. 0.65 1.50 298
70 Watt Pulse Start Metal Halide 240 Super C.W.A. 0.60 1.30 298
120 HX-HPF 0.80 0.85 95 277 Super C.W.A. 0.50 1.12 298
208 HX-HPF 0.50 0.52 95 480 Super C.W.A. 0.30 0.65 298
240 HX-HPF 0.43 0.44 95
277 HX-HPF 0.39 0.39 95
347 V HX-HPF 0.20 0.28 88
480 HX-HPF 0.26 0.23 95
100 Watt Pulse Start Metal Halide
120 HX-HPF 1.20 1.15 130
208 HX-HPF 0.70 0.70 130
240 HX-HPF 0.61 0.58 130
277 HX-HPF 0.55 0.50 130
347 V HX-HPF 0.40 0.40 129
480 HX-HPF 0.30 0.35 140

➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance High Power Factor Autotransformer. Super C.W.A. – Super Constant Wattage Autotransformer.
➋ 150 W HPS units equipped with ballasts to operate 55 volt lamps only.
V CSA Certification only.

964 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Dimensions
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Pendant Ceiling Cone


(Rigid or Flex)
13.62”/345.9mm
1.17”/
12.06”/306.3mm
12.06”/306.3mm 29.7mm 12.06”/306.3mm

Lighting
1.75”/
44.5mm 5.59”/
142.0mm
5.87”/ 5.87”/
149.1mm 149.1mm
5.87”/
149.1mm
11.00”/279.4mm

Lighting: Enclosed and Gasketed — Area — HID


11.00”/279.4mm

11.00”/279.4mm

Wall

2.75”/69.9mm
17.06”/433.3mm Globe/Guard/Refractor
6.00”/152.4mm
2.62”/66.5mm 1.94”/49.3mm 9.00”/228.6mm
6.50”/
165.1mm
5.87”/
149.1mm
8.00”/
203.2mm
11.00”/279.4mm

17.23”/437.6mm  10.17”/
4.75”/ 1.87”/47.5mm 258.3mm
9.79”/248.7mm 

120.7mm 15.07”/382.8mm

4.00”/ 1.94”/49.3mm 16.90”/429.3mm


101.6mm 90º Straight Stanchion

5.87”/ 14.90”/
0.94”/ 5.87”/
149.1mm 378.5mm
23.9mm 149.1mm

11.00”/279.4mm

 11.00”/279.4mm 8” Globe/Refractor
5.50”/ Body/Guard
139.7mm
5.50”/ 13.38”/339.9mm
139.7mm Polymeric Refractor
1.94”/ 5.50”/
49.3mm 11.00”/279.4mm 5.87”/149.1mm 139.7mm
14.94”/379.5mm
13.38”/339.9mm
25° Angle Stanchion
5.87”/
1.94”/
49.3mm 149.1mm 7.75”/196.9mm 10.75”/
14.94”/379.5mm 11.00”/279.4mm 5.87”/149.1mm 7.25”/184.2mm 273.1mm
6.06”/
153.9mm 5.87”/
149.1mm 7.75”/196.9mm 7.25”/184.2mm
6.06”/
153.9mm
12.38”/
7.78”/199.9mm
7.78”/199.9mm 314.5mm
11.00”/
11.00”/
279.4mm
279.4mm

6.69”/
169.9mm
6.69”/
169.9mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 965


© September 2010
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED

Class I, Division 2, Groups A, B, C, D


NEMA 4X

Applications Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn • Encapsulated with epoxy sealing compound
lighting control in Class I, Division 2 locations. • FS: aluminum
• Typical applications include walkways, security areas and any
other outdoor lighting application.
Certifications and Compliances
Lighting

• For use with Mercmaster III – Low Profile, Mercmaster III, and • UL Standard: 1604 ­– Hazardous (Classified) Locations
Mercmaster III – 400 Series Luminaires. • cULus Recognized
• For remote mounting in FS Boxes.
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
Lighting: Enclosed and Gasketed — Area — HID

• Solid state design for performance and reliability.


• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisiance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
• Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1. Dimensions
Voltage Range Suffix Designation
120 V, 50/60 Hz H1
208 V, 50/60 Hz H2
240 V, 50/60 Hz H3
277 V, 50/60 Hz H4
Mercmaster III wall mounting hood
with photocontrol installed shown
1.13”
28.7 mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box


Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range Catalog Number


120V, 50/60 Hz FSKA-PC120D2
1.375”
34.9 mm
208-277V, 50/60 Hz FSKA-PC247D2 1.375”
34.9 mm

2.56”
65.0 mm
2.56”
1.13” 65.0 mm
28.7 mm

Photocontrol for Field Installation


Voltage Range Max. Current Catalog Number
120 V, 50/60 Hz 8.3 Amp PC120D2
1.375”
208-277 V, 50/60 Hz 3.5 Amp PC247D2
34.9 mm 0.69”
17.5 mm

1.19”
2.56” 30.2 mm
65.0 mm 1.94”
49.2 mm

966 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with For candlepower values of fixtures with other
150-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers: for
(16,000 lumen). 70 W (6,400 lumen) HPS lamp – 0.40; for 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Zone Lumens Total Luminaire Efficiency = 86.1%

0-10 50.74 CIE Type – Semi-Direct REPORT NUMBER: KP15LG


10-20 164.55
Spacing
Lamps: 150 W High Pressure Sodium with Globe only *

Lighting
20-30 310.47 Plane Criteria

30-40 611.05 0-180 2.82 Coefficients of Utilization – Zonal Cavity Method

40-50 961.13 90-270 2.82 Effective Floor Cavity Reflectance 0.20

50-60 1308.18 Diagonal 2.80 % Ceiling Rcc 80 70 50 30 10 0

60-70 1542.35 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Lighting: Enclosed and Gasketed — Area — HID


70-80 1716.10 Zonal Lumen Summary 0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 57 57 57 53

80-90 1799.18 Zone Lumens % Lamp % Fixture 1 81 74 69 64 75 69 64 59 59 55 51 50 47 44 42 39 37 33


90-100 1802.19 0-30 525.75 3.3 3.8 2 71 62 54 47 65 57 50 44 49 43 38 41 36 32 33 30 27 23
100-110 1676.86 0-40 1136.81 7.1 8.3 3 64 52 44 37 58 48 41 34 41 35 30 34 29 25 28 24 20 17
110-120 1379.11 0-60 3406.12 21.3 24.7 4 57 45 36 30 53 42 34 28 35 29 24 29 24 20 24 19 16 13
120-130 441.46 0-90 8463.75 52.9 61.4 5 52 40 31 24 48 37 29 23 31 24 19 26 20 16 21 16 13 10
130-140 9.61 90-120 4858.16 30.4 35.3 6 48 35 26 20 44 32 25 19 27 21 16 23 17 13 18 14 11 8
140-150 3.33 90-130 5299.62 33.1 38.5 7 44 31 23 17 40 29 21 16 24 18 14 20 15 11 16 12 9 7
150-160 0.74 90-150 5312.56 33.2 38.5 8 40 28 20 15 37 26 19 14 22 16 12 18 13 10 15 11 8 6
160-170 0.00 90-180 5313.30 33.2 38.6 9 38 25 18 13 35 24 17 12 20 14 10 17 12 8 14 10 7 5
170-180 0.00 180-0 13777.05 86.1 100.0 10 35 23 16 11 32 22 15 11 18 13 9 15 11 7 13 9 6 4

Zone Lumens Total Luminaire Efficiency = 73.6%

0-10 266.98 CIE Type – Direct REPORT NUMBER: KP15LST


10-20 799.41 Lamps: 150 W High Pressure Sodium with
Spacing
20-30 1337.05 Plane Criteria Standard Dome Reflector *
30-40 1732.06 0-180 1.46 Coefficients of Utilization - Zonal Cavity Method

40-50 2067.60 90-270 1.46 Effective Floor Cavity Reflectance 0.20

50-60 2317.60 Diagonal 1.68 % Ceiling Rcc 80 70 50 30 10 0

60-70 2210.81 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 866.77 Zonal Lumen Summary 0 88 88 88 88 86 86 86 86 82 82 82 78 78 78 75 75 75 73

80-90 145.09 Zone Lumens % Lamp % Fixture 1 79 76 72 69 77 74 71 68 71 68 66 68 66 64 65 64 62 60


90-100 14.46 0-30 2403.44 15.0 20.4 2 71 65 59 55 69 63 58 54 61 57 53 58 55 52 56 53 50 49
100-110 8.75 0-40 4135.50 25.8 35.1 3 64 56 49 44 62 55 49 44 52 47 43 50 46 42 48 45 41 40
110-120 7.93 0-60 8520.70 53.3 72.3 4 58 49 42 36 57 48 41 36 46 40 36 44 39 35 42 38 35 33
120-130 4.51 0-90 11743.37 73.4 99.7 5 53 43 36 31 52 42 35 30 40 35 30 39 34 30 38 33 29 28
130-140 2.16 90-120 31.14 0.2 0.3 6 49 38 31 26 47 38 31 26 36 30 26 35 30 25 34 29 25 24
140-150 0.48 90-130 35.65 0.2 0.3 7 45 34 27 23 44 34 27 23 33 27 22 31 26 22 30 26 22 20
150-160 0.00 90-150 38.29 0.2 0.3 8 42 31 24 20 40 31 24 20 30 24 20 29 23 19 28 23 19 18
160-170 0.00 90-180 38.29 0.2 0.3 9 39 28 22 18 38 28 22 18 27 21 17 26 21 17 25 21 17 16
170-180 0.00 180-0 11781.65 73.6 100.0 10 36 26 20 16 35 26 20 16 25 19 16 24 19 16 23 19 15 14

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 967


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with For candlepower values of fixtures with other
150-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers: for
(16,000 lumen). 70 W (6,400 lumen) HPS lamp – 0.40; for 50 W
(4,000 lumen) HPS lamp – ­0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Zone Lumens Total Luminaire Efficiency = 73.1%

0-10 222.62 CIE Type - Direct REPORT NUMBER: KP15LAN


10-20 664.6 Lamps: 150 W High Pressure Sodium with
Spacing
30° Angle Dome Reflector *
Lighting

20-30 1084.32 Plane Criteria

30-40 1536.55 0-180 2.06 Coefficients of Utilization - Zonal Cavity Method

40-50 1771.90 90-270 1.58 Effective Floor Cavity Reflectance 0.20

50-60 1771.51 Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0

60-70 1668.93 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0


Lighting: Enclosed and Gasketed — Area — HID

70-80 1422.36 Zonal Lumen Summary 0 86 86 86 86 84 84 84 84 79 79 79 75 75 75 71 71 71 70

80-90 994.54 Zone Lumens % Lamp % Fixture 1 76 71 67 63 73 69 65 62 65 62 59 62 59 57 58 56 54 52


90-100 432.23 0-30 1971.54 12.3 16.9 2 68 60 54 49 65 58 53 48 55 50 46 52 48 45 49 46 43 41
100-110 104.58 0-40 3508.09 21.9 30.0 3 61 52 45 39 59 50 44 39 48 42 37 45 40 36 43 39 35 33
110-120 20.99 0-60 7051.50 44.1 60.3 4 55 45 38 32 53 44 37 32 42 36 31 39 34 30 37 33 29 27
120-130 1.21 0-90 11137.33 69.6 95.2 5 50 40 33 27 49 39 32 27 37 31 26 35 30 25 33 29 25 23
130-140 0.04 90-120 557.80 3.5 4.8 6 46 36 28 23 45 35 28 23 33 27 22 31 26 22 30 25 21 20
140-150 0.00 90-130 559.01 3.5 4.8 7 43 32 25 20 41 31 25 20 30 24 19 28 23 19 27 22 19 17
150-160 0.00 90-150 559.04 3.5 4.8 8 40 29 22 18 38 28 22 17 27 21 17 26 21 17 25 20 16 15
160-170 0.00 90-180 559.04 3.5 4.8 9 37 26 20 16 36 26 20 16 25 19 15 24 19 15 23 18 15 13
170-180 0.00 180-0 11696.38 73.1 100.0 10 35 24 18 14 33 24 18 14 23 17 14 22 17 13 21 16 13 12

Zone Lumens Total Luminaire Efficiency = 81.1%

0-10 72.83 CIE Type - Semi- Direct REPORT NUMBER: KP15LJR5


10-20 222.26 Lamps: 150 W High Pressure Sodium with
Spacing
20-30 380.73 Plane Criteria 8” Prismatic Glass Refracter - NEMA Type V *
30-40 621.11 0-180 1.98 Coefficients of Utilization - Zonal Cavity Method

40-50 852.53 90-270 1.98 Effective Floor Cavity Reflectance 0.20

50-60 1765.29 Diagonal 3.40 % Ceiling Rcc 80 70 50 30 10 0

60-70 3192.58 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 2366.61 Zonal Lumen Summary 0 93 93 93 93 89 89 89 89 82 82 82 76 76 76 70 70 70 67

80-90 1230.65 Zone Lumens % Lamp % Fixture 1 80 73 68 63 76 70 65 61 64 60 56 58 55 52 53 50 48 45


90-100 450.14 0-30 675.83 4.2 5.2 2 69 59 51 45 65 56 49 43 51 45 40 46 41 37 41 37 34 31
100-110 712.41 0-40 1296.93 8.1 10.0 3 61 49 40 33 57 47 38 32 42 35 29 38 32 27 34 29 25 22
110-120 499.15 0-60 3914.76 24.5 30.2 4 54 42 32 25 51 40 31 24 35 28 22 32 26 21 28 23 19 16
120-130 323.44 0-90 10704.60 66.9 82.5 5 49 36 27 20 46 34 26 19 31 23 18 27 21 16 24 19 15 12
130-140 185.00 90-120 1661.70 10.4 12.8 6 45 32 23 16 42 30 22 16 27 20 14 24 18 13 21 16 12 10
140-150 81.31 90-130 1985.14 12.4 15.3 7 41 28 20 14 38 27 19 13 24 17 12 21 15 11 19 14 10 8
150-160 21.08 90-150 2251.45 14.1 15.3 8 38 25 17 12 36 24 16 11 22 15 10 19 14 9 17 12 8 6
160-170 2.81 90-180 2275.34 14.2 17.5 9 35 23 15 10 33 22 15 10 20 13 9 18 12 8 16 11 7 5
170-180 0.00 180-0 12979.94 81.1 100.0 10 33 21 14 9 31 20 13 9 18 12 8 16 11 7 15 10 6 5

968 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with a For candlepower values of fixtures with other
175-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: for a
(17,500 lumen). 100 W (8,500 lumen) PSMH lamp – 0.49; for a 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.

Zone Lumens Total Luminaire Efficiency = 75.4%

0-10 57.98 CIE Type - General Diffuse REPORT NUMBER: KP17PG


10-20 217.30 Lamps: 175 W Pulse Start Metal Halide with Globe only *

Lighting
20-30 372.71

30-40 696.29 Coefficients of Utilization - Zonal Cavity Method

40-50 1009.65 Effective Floor Cavity Reflectance 0.20

50-60 1226.57 % Ceiling Rcc 80 70 50 30 10 0

60-70 1473.76 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Lighting: Enclosed and Gasketed — Area — HID


70-80 1757.30 Zonal Lumen Summary 0 93 93 93 93 87 87 87 87 75 75 75 64 64 64 54 54 54 50

80-90 1902.34 Zone Lumens % Lamp % Fixture 1 79 73 68 63 73 68 63 59 58 54 50 48 45 43 40 37 35 31


90-100 1946.09 0-30 647.99 3.7 4.3 2 70 61 54 47 65 57 50 44 48 42 38 39 35 32 32 29 26 22
100-110 1829.51 0-40 1344.28 7.7 9.0 3 63 52 44 37 58 48 41 35 40 34 29 33 28 24 27 23 20 16
110-120 1657.20 0-60 3580.49 20.5 24.0 4 57 45 37 30 52 42 34 28 35 29 24 29 24 20 23 19 16 12
120-130 750.27 0-90 8713.89 49.8 58.4 5 52 40 31 25 47 37 29 23 31 24 20 25 20 16 20 16 13 10
130-140 14.15 90-120 5432.80 31.0 36.4 6 47 35 27 21 43 32 25 19 27 21 17 22 17 14 18 14 11 8
140-150 4.47 90-130 6183.06 35.3 41.4 7 44 31 23 18 40 29 22 17 24 18 14 20 15 12 16 12 9 7
150-160 0.52 90-150 6201.69 35.4 41.6 8 40 28 21 15 37 26 19 14 22 16 12 18 14 10 15 11 8 6
160-170 1.35 90-180 6203.74 35.4 41.6 9 37 26 18 13 34 24 17 13 20 15 11 17 12 9 13 10 7 5
170-180 0.18 180-0 14917.63 85.2 100.0 10 35 23 16 12 32 22 15 11 18 13 9 15 11 8 12 9 6 4

Zone Lumens Total Luminaire Efficiency = 72.3%

0-10 285.95 CIE Type - Direct REPORT NUMBER: KP17PST


10-20 876.46 Lamps: 175 W Pulse Start Metal Halide with
Spacing
20-30 1472.88 Plane Criteria Standard Dome Reflector *
30-40 1924.39 0-180 1.50 Coefficients of Utilization - Zonal Cavity Method

40-50 2213.42 90-270 1.50 Effective Floor Cavity Reflectance 0.20

50-60 2305.55 Diagonal 1.66 % Ceiling Rcc 80 70 50 30 10 0

60-70 2256.32 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 1115.75 Zonal Lumen Summary 0 86 86 86 86 84 84 84 84 80 80 80 77 77 77 74 74 74 72

80-90 198.05 Zone Lumens % Lamp % Fixture 1 78 74 71 68 76 72 69 67 69 67 65 67 64 63 64 62 61 59


90-100 3.56 0-30 2635.28 15.1 20.8 2 70 63 58 54 68 62 57 53 59 55 52 57 54 50 55 52 49 48
100-110 0.00 0-40 4559.67 26.1 36.0 3 63 55 48 43 61 54 48 43 51 46 42 49 45 41 47 44 41 39
110-120 0.00 0-60 9078.64 51.9 71.8 4 57 48 41 36 56 47 40 35 45 39 35 43 38 34 42 37 34 32
120-130 0.00 0-90 12648.77 72.3 100.0 5 52 42 35 30 51 41 35 30 40 34 30 38 33 29 37 32 29 27
130-140 0.00 90-120 3.56 0.00 0.00 6 48 38 31 26 47 37 30 26 36 30 25 34 29 25 33 29 25 23
140-150 0.00 90-130 3.56 0.00 0.00 7 44 34 27 22 43 33 27 22 32 26 22 31 26 22 30 25 22 20
150-160 0.00 90-150 3.56 0.00 0.00 8 41 31 24 20 40 30 24 20 29 24 19 28 23 19 27 23 19 18
160-170 0.00 90-180 3.56 0.00 0.00 9 38 28 22 18 37 28 22 17 27 21 17 26 21 17 25 21 17 16
170-180 0.00 180-0 12652.33 72.3 100.0 10 36 26 20 16 35 25 20 16 25 19 16 24 19 15 23 19 15 14

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 969


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with a For candlepower values of fixtures with other
175-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: for
(17,500 lumen). a 100 W (8,500 lumen) PSMH lamp – 0.49; for 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.

Zone Lumens Total Luminaire Efficiency = 67.1%

0-10 240.21 CIE Type - Direct REPORT NUMBER: KP17PAN


10-20 750.99 Lamps: 175 W Pulse Start Metal Halide with
Spacing
30° Angle Dome Reflector *
Lighting

20-30 1195.39 Plane Criteria

30-40 1662.85 0-180 1.96 Coefficients of Utilization - Zonal Cavity Method

40-50 1830.67 90-270 1.70 Effective Floor Cavity Reflectance 0.20

50-60 1740.13 Diagonal 1.56 % Ceiling Rcc 80 70 50 30 10 0

60-70 1571.75 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0


Lighting: Enclosed and Gasketed — Area — HID

70-80 1324.18 Zonal Lumen Summary 0 79 79 79 79 77 77 77 77 73 73 73 69 69 69 66 66 66 64

80-90 900.65 Zone Lumens % Lamp % Fixture 1 70 66 62 59 68 64 61 58 60 58 55 57 55 53 54 52 51 49


90-100 367.96 0-30 2186.59 12.5 18.6 2 63 56 51 46 61 55 49 45 52 47 44 49 45 42 46 43 41 39
100-110 107.38 0-40 3849.44 22.0 32.8 3 57 48 42 37 55 47 41 37 45 40 36 42 38 35 40 37 34 32
110-120 27.79 0-60 7420.24 42.4 63.2 4 51 42 36 31 50 41 35 30 39 34 30 37 33 29 35 31 28 26
120-130 5.54 0-90 11216.82 64.1 95.6 5 47 38 31 26 45 37 30 26 35 29 25 33 28 25 32 27 24 22
130-140 4.20 90-120 503.12 2.9 4.3 6 43 34 27 22 42 33 27 22 31 26 22 30 25 21 28 24 21 19
140-150 4.42 90-130 508.66 2.9 4.3 7 40 30 24 20 39 30 24 19 28 23 19 27 22 19 26 22 18 17
150-160 2.00 90-150 517.28 3.0 4.4 8 37 27 21 17 36 27 21 17 26 20 17 25 20 16 24 19 16 15
160-170 1.70 90-180 521.31 3.0 4.4 9 35 25 19 15 33 25 19 15 24 18 15 23 18 15 22 18 14 13
170-180 0.33 180-0 11738.13 67.1 100.0 10 32 23 17 14 31 23 17 14 22 17 13 21 16 13 20 16 13 12

Zone Lumens Total Luminaire Efficiency = 81.1%

0-10 22.77 CIE Type - Semi-Direct REPORT NUMBER: KP17PJR5


10-20 171.20 Lamps: 175 W Pulse Start Metal Halide with
Spacing
20-30 325.41 Plane Criteria 8” Prismatic Glass Refracter - NEMA Type V *
30-40 531.35 0-180 1.66 Coefficients of Utilization - Zonal Cavity Method

40-50 1173.62 90-270 1.64 Effective Floor Cavity Reflectance 0.20

50-60 1165.11 Diagonal 1.92 % Ceiling Rcc 80 70 50 30 10 0

60-70 3171.29 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 3719.35 Zonal Lumen Summary 0 94 94 94 94 90 90 90 90 83 83 83 77 77 77 71 71 71 69

80-90 1751.05 Zone Lumens % Lamp % Fixture 1 78 71 65 60 74 68 62 57 62 57 53 57 53 49 51 48 46 43


90-100 523.23 0-30 519.38 3.0 3.7 2 67 57 48 41 63 54 46 39 49 42 36 44 38 33 39 35 31 28
100-110 716.53 0-40 1050.73 6.0 7.4 3 59 46 37 29 55 44 35 28 40 32 26 35 29 24 32 26 22 19
110-120 431.18 0-60 3389.46 19.4 23.9 4 52 39 30 22 49 37 28 21 33 26 20 30 23 18 26 21 16 14
120-130 265.20 0-90 12031.16 68.7 84.8 5 47 34 24 17 45 32 23 17 29 21 15 26 19 14 23 17 13 10
130-140 142.69 90-120 1670.94 9.5 11.8 6 43 30 21 14 41 28 20 14 25 18 12 23 16 11 20 15 10 8
140-150 57.09 90-130 1936.15 11.1 13.7 7 40 27 18 12 37 23 17 11 23 16 10 20 14 9 18 13 8 6
150-160 13.48 90-150 2135.93 12.2 15.1 8 37 24 16 10 35 23 15 10 20 14 9 18 12 8 16 11 7 5
160-170 2.44 90-180 2152.72 12.3 15.2 9 34 22 14 9 32 21 13 8 19 12 8 17 11 7 15 10 6 4
170-180 0.88 180-0 14183.88 81.1 100.0 10 32 20 12 8 30 19 12 7 17 11 7 16 10 6 14 9 5 4

970 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with a For candlepower values of fixtures with other
175-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: for a
(17,500 lumen). 100 W (8,500 lumen) PSMH lamp – 0.49; for a 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.

Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 70.8%


0 657 CIE Type – Semi-Direct
REPORT NUMBER: KPB175PG3
5 668 65 Spacing Criteria: 1.7 Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
15 784 224 G3 Globe only
25 966 451

Lighting
35 1194 705 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 871 711 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1267 1142 RC 80 70 50 30 10 0
65 1309 1303 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 1430 1509 0 78 78 78 78 73 73 73 73 64 64 64 56 56 56 48 48 48 44
85 1528 1661 1 67 61 57 53 62 57 53 49 49 46 43 42 39 37 35 33 31 28
90 1537 ZONAL LUMEN SUMMARY 2 59 51 45 40 54 48 42 37 41 36 32 34 31 27 28 26 23 20
95 1552 1680 ZONE LUMENS %LAMP %FIXT. 3 53 44 37 31 49 40 34 29 34 29 25 29 25 21 24 21 18 15
105 1452 1532 0-30 740 4.2 6.0 4 48 38 31 25 44 35 29 24 30 25 20 25 21 17 21 17 14 12

Lighting: Enclosed and Gasketed — Area — HID


115 1339 1232 0-40 1445 8.3 11.7 5 43 33 26 21 40 31 24 20 26 21 17 22 18 14 18 15 12 9
125 68 143 0-60 3297 18.8 26.6 6 40 29 23 18 37 27 21 16 23 18 14 20 15 12 16 13 10 8
135 19 16 0-90 7770 44.4 62.7 7 37 26 20 15 34 25 18 14 21 16 12 18 13 10 15 11 9 7
145 13 11 90-120 4444 25.4 35.9 8 34 24 17 13 31 22 16 12 19 14 11 16 12 9 13 10 7 6
155 7 3 90-130 4586 26.2 37.0 9 32 22 16 11 29 20 15 11 17 13 9 15 11 8 12 9 7 5
165 1 1 90-150 4613 26.4 37.2 10 29 20 14 10 27 18 13 9 16 11 8 14 10 7 11 8 6 4
175 2 0 90-180 4617 26.4 37.3
180 7 0-180 12387 70.8 100.0

Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 65.6% REPORT NUMBER: KPB175PG3_ST
0 2785 CIE Type – Direct
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
5 2797 269 Spacing Criteria: 1.5
15 2902 823 G3 Globe and Standard Dome Reflector
90°
25 2931 1358
35 2979 1821 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 2388 1874 75° EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 2393 2145 950 RC 80 70 50 30 10 0
65 2044 2034 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 664 856 60° 0 78 78 78 78 76 76 76 76 73 73 73 69 69 69 66 66 66 65
85 150 183 1 71 67 64 62 69 66 63 61 63 61 59 60 58 57 58 56 55 53
90 24 ZONAL LUMEN SUMMARY 1500 2 64 58 53 49 62 57 52 48 54 50 47 52 49 46 50 47 45 43
95 5 11 ZONE LUMENS %LAMP %FIXT. 45°
3 58 50 44 40 56 49 44 39 47 42 39 45 41 38 43 40 37 35
105 16 17 0-30 2450 14.0 21.3 4 52 44 38 33 51 43 37 33 41 36 32 39 35 32 38 34 31 29
115 91 73 0-40 4271 24.4 37.2 5 48 39 32 28 46 38 32 28 36 31 27 35 30 27 34 30 26 25
125 5 9 0-60 8290 47.4 72.2 6 44 35 28 24 42 34 28 24 33 27 23 31 27 23 30 26 23 21
2850
135 7 3 0-90 11363 64.9 99.0 7 40 31 25 21 39 30 25 21 29 24 20 28 24 20 27 23 20 19
145 8 2 90-120 101 0.6 0.9 0° 15° 30° 8 37 28 22 18 36 28 22 18 27 22 18 26 21 18 25 21 18 16
155 2 2 90-130 110 0.6 1.0 9 35 26 20 16 34 25 20 16 24 19 16 24 19 16 23 19 16 15
165 2 0 90-150 115 0.7 1.0 10 33 24 18 15 32 23 18 15 23 18 14 22 17 14 21 17 14 13
175 2 1 90-180 118 0.7 1.0
180 11 0-180 11481 65.6 100.0

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 58.2% REPORT NUMBER: KPB175PG3_AN


0.0 45.0 90.0 135.0 180.0 Flux CIE Type – Direct Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
0 2333 2333 2333 2333 2333 Spacing G3 Globe and 30° Angle Dome Reflector
5 2491 2467 2321 2205 2141 223 Plane Criteria
15 2904 2753 2337 2160 2099 692 0° 1.8
25 3010 2891 2480 2242 2120 1170 90° 1.5 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
35 3471 3100 2544 2027 1367 1512 180° 1.1 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
45 2978 2719 1993 832 546 1427 RC 80 70 50 30 10 0
55 3296 2939 1791 421 154 1533 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
65 3153 2801 776 74 0 1349 0 69 69 69 69 67 67 67 67 63 63 63 60 60 60 57 57 57 56
75 3175 2621 392 3 0 1140 1 61 57 54 51 59 56 53 50 53 50 48 50 48 46 48 46 45 43
85 2729 967 117 5 0 709 2 55 49 44 40 53 48 43 40 45 42 38 43 40 37 41 38 36 34
90 1601 662 11 5 5 ZONAL LUMEN SUMMARY 3 49 42 37 33 48 41 36 32 39 35 31 37 34 31 35 32 30 28
95 790 461 3 11 16 247 ZONE LUMENS %LAMP %FIXT. 4 45 37 32 27 43 36 31 27 34 30 26 33 29 26 31 28 25 24
105 413 175 11 19 21 109 0-30 2085 11.9 20.5 5 41 33 27 23 40 32 27 23 31 26 22 29 25 22 28 24 21 20
115 117 8 8 29 90 56 0-40 3597 20.6 35.3 6 38 30 24 20 37 29 24 20 28 23 19 26 22 19 25 22 19 17
125 5 11 13 13 11 2 0-60 6557 37.5 64.4 7 35 27 21 18 34 26 21 17 25 20 17 24 20 17 23 19 16 15
135 0 3 3 3 0 1 0-90 9755 55.7 95.8 8 33 24 19 16 32 24 19 15 23 18 15 22 18 15 21 17 15 13
0-deg
Legend

145 5 5 11 5 0 4 90-120 412 2.4 4.1 9 30 22 17 14 29 22 17 14 21 17 14 20 16 13 19 16 13 12


155 0 3 5 5 0 2 90-130 415 2.4 4.1
90-deg 10 28 20 16 12 28 20 15 12 19 15 12 19 15 12 18 14 12 11
165 5 3 8 5 0 1 90-150 420 2.4 4.1 180-deg
175 0 5 3 3 0 0 90-180 423 2.4 4.2
180 6 6 6 6 6 0-180 10178 58.2 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 971


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
100 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with a For candlepower values of fixtures with other
100-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers: for a 70
(9,400 lumen). W (6,400 lumen) HPS lamp – 0.68; for 50 W (4,000
lumen) HPS lamp – 0.43; for candlepower values
of fixture with guard, multiply by 0.95.

Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 84.1% REPORT NUMBER: KPB100LG3
0 269 CIE Type – Semi-Direct Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
5 267 27 Spacing Criteria: 3.1 Mogul Base with G3 Globe only
15 407 117
25 571 267
Lighting

35 748 442 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD


45 451 380 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 848 735 RC 80 70 50 30 10 0
65 915 908 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 976 1033 0 93 93 93 93 87 87 87 87 76 76 76 66 66 66 57 57 57 53
85 1021 1113 1 79 72 67 62 73 67 62 58 58 54 50 49 46 43 41 39 36 32
90 1027 ZONAL LUMEN SUMMARY 2 69 60 52 46 64 56 49 43 48 42 37 40 36 32 33 30 26 23
95 1019 1109 ZONE LUMENS %LAMP %FIXT. 3 62 51 43 36 57 47 40 34 40 34 29 34 29 24 28 24 20 17
105 953 1002 0-30 410 4.3 5.1 4 56 44 36 29 51 41 33 27 35 28 23 29 24 20 24 19 16 13
Lighting: Enclosed and Gasketed — Area — HID

115 791 734 0-40 852 9.0 10.7 5 51 39 30 24 47 36 28 22 30 24 19 25 20 16 21 17 13 10


125 54 103 0-60 1967 20.7 24.6 6 47 34 26 20 43 32 24 19 27 21 16 23 17 13 19 14 11 8
135 13 9 0-90 5021 52.9 62.9 7 43 31 23 17 40 28 21 16 24 18 14 20 15 13 17 13 9 7
145 13 8 90-120 2845 29.9 35.6 8 40 28 20 15 37 26 19 14 22 16 12 19 14 10 15 11 8 6
155 4 2 90-130 2948 31.0 36.9 9 37 25 18 13 34 23 17 12 20 14 10 17 12 9 14 10 7 5
165 0 0 90-150 2965 31.2 37.1 10 34 23 16 11 32 21 15 11 18 13 9 16 11 8 13 9 6 5
175 0 0 90-180 2967 31.2 37.1
180 1 0-180 7988 84.1 100.0

Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 72.9% REPORT NUMBER: KPB100LG3_ST
0 1466 CIE Type – Direct Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
5 1473 142 Spacing Criteria: 1.6 Mogul Base with G3 Globe and Standard Dome Reflector
15 1607 456
25 1675 775
35 1757 1071 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 1316 1047 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1502 1316 RC 80 70 50 30 10 0
65 1377 1362 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 465 589 0 87 87 87 87 85 85 85 85 81 81 81 77 77 77 74 74 74 72
85 92 111 1 78 74 71 68 76 73 70 67 70 67 65 67 64 62 64 62 60 59
90 16 ZONAL LUMEN SUMMARY 2 70 64 58 53 68 62 57 53 59 55 51 57 53 50 54 52 49 47
95 3 5 ZONE LUMENS %LAMP %FIXT. 3 63 55 48 43 61 54 47 43 51 46 42 49 45 41 47 43 40 38
105 6 6 0-30 1373 14.5 19.8 4 57 48 41 35 55 47 40 35 45 39 34 43 38 34 41 37 33 32
115 40 33 0-40 2445 25.7 35.3 5 52 42 35 30 51 41 34 29 39 34 29 38 33 29 36 32 28 26
125 5 8 0-60 4807 50.6 69.4 6 48 37 30 25 46 37 30 25 35 29 25 34 29 25 33 28 24 23
135 3 2 0-90 6869 72.3 99.2 7 44 34 27 22 43 33 26 22 32 26 22 31 25 21 29 25 21 20
145 3 1 90-120 45 0.5 0.6 8 41 30 24 19 40 30 24 19 29 23 19 28 23 19 27 22 19 17
155 2 1 90-130 53 0.6 0.8 9 38 23 21 17 37 27 21 17 26 21 17 25 20 17 25 20 17 15
165 0 1 90-150 56 0.6 0.8 10 36 25 19 15 35 25 19 15 24 19 15 23 19 15 23 18 15 14
175 1 0 90-180 58 0.6 0.8
180 1 0-180 6927 72.9 100.0

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 65.0% REPORT NUMBER: KPB100LG3_AN


0.0 45.0 90.0 135.0 180.0 Flux CIE Type – Direct Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
0 1270 1270 1270 1270 1270 Spacing Mogul Base with G3 Globe and 30° Angle Reflector
5 1317 1302 1271 1227 1211 122 Plane Criteria
15 1554 1471 1384 1341 1298 398 0° 1.9
25 1779 1680 1528 1353 1246 694 90° 1.7 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
35 1923 1830 1593 1256 1020 917 180° 1.3 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
45 1715 1564 1163 599 361 848 RC 80 70 50 30 10 0
55 1981 1862 1100 287 122 953 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
65 1923 1751 869 104 0 869 0 77 77 77 77 75 75 75 75 71 71 71 67 67 67 64 64 64 62
75 1879 1272 298 9 0 711 1 68 64 61 57 66 62 59 56 59 56 54 56 54 52 53 51 50 48
85 1371 828 140 1 0 424 2 61 55 49 45 59 53 48 44 50 46 43 48 44 41 45 42 40 38
90 680 422 89 2 1 ZONAL LUMEN SUMMARY 3 55 47 41 36 53 46 40 36 44 39 35 41 37 34 39 36 33 31
95 416 259 47 4 4 144 ZONE LUMENS %LAMP %FIXT. 4 50 41 35 30 48 40 34 30 38 33 29 36 32 28 35 31 28 26
105 191 93 4 7 6 59 0-30 1213 12.8 19.7 5 46 37 30 25 44 36 30 25 34 29 25 32 28 24 31 27 24 22
115 40 18 51 54 92 31 0-40 2131 22.4 34.5 6 42 33 26 22 41 32 26 22 30 25 21 29 24 21 28 24 20 19
125 1 3 3 3 1 2 0-60 3932 41.4 63.7 7 39 30 23 19 38 29 23 19 28 22 19 26 22 18 25 21 18 17
0-deg
Legend

135 1 2 3 2 1 1 0-90 5936 62.5 96.1 8 36 27 21 17 35 26 21 17 25 20 16 24 20 16 23 19 16 15


90-deg
145 0 1 2 0 0 1 90-120 234 2.5 3.8 9 34 25 19 15 33 24 19 15 23 18 15 22 18 14 21 17 14 13
155 0 1 2 1 0 1 90-130 236 2.5 3.8 180-deg 10 32 23 17 14 31 22 17 13 21 17 13 20 16 13 20 16 13 12
165 0 1 1 1 0 0 90-150 238 2.5 3.9
175 2 2 2 1 0 0 90-180 239 2.5 3.9
180 2 2 2 2 2 0-180 6175 65.0 100.0

972 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with a For candlepower values of fixtures with other
150-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers: for a
(16,000 lumen). 70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 81.1% REPORT NUMBER: KPB150LG3
0 488 CIE Type – Semi-Direct Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
5 459 46 Spacing Criteria: 3.0 Base with G3 Globe only
15 703 202
25 938 442

Lighting
35 1107 672 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 892 710 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 1420 1253 RC 80 70 50 30 10 0
65 1542 1529 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 1629 1723 0 90 90 90 90 84 84 84 84 74 74 74 65 65 65 56 56 56 53
85 1675 1824 1 76 70 65 60 71 65 60 56 56 53 49 48 45 42 41 38 36 32
90 1665 ZONAL LUMEN SUMMARY 2 67 58 51 44 62 54 47 42 46 41 36 39 35 31 33 29 26 23
95 1643 1788 ZONE LUMENS %LAMP %FIXT. 3 60 49 41 34 55 46 38 32 39 33 28 33 28 24 27 23 20 17
105 1515 1599 0-30 689 4.3 5.3 4 54 43 34 29 50 40 32 26 34 27 22 28 23 19 23 19 16 13

Lighting: Enclosed and Gasketed — Area — HID


115 1072 1042 0-40 1361 8.5 10.5 5 49 37 29 23 45 35 27 21 30 23 18 25 20 16 21 16 13 10
125 51 115 0-60 3324 20.8 25.6 6 45 33 25 19 42 31 23 18 26 20 15 22 17 13 18 14 11 8
135 20 16 0-90 8400 52.5 64.7 7 41 30 22 16 38 27 20 15 24 18 13 20 15 11 16 12 9 7
145 19 12 90-120 4429 27.7 34.1 8 38 27 19 14 35 25 18 13 21 16 11 18 13 10 15 11 8 6
155 6 4 90-130 4544 28.4 35.0 9 36 24 17 12 33 23 16 12 19 14 10 17 12 8 14 10 7 5
165 1 0 90-150 4572 28.6 35.2 10 33 22 15 11 31 21 14 10 18 12 9 15 11 7 13 9 6 4
175 0 0 90-180 4576 28.6 35.3
180 2 0-180 12976 81.1 100.0

Degree Candela Lumens TOTAL LUMINAIRE EFFICIENCY = 69.6% REPORT NUMBER: KPB150LG3_ST
0 2403 CIE Type – Direct Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
5 2391 230 Spacing Criteria: 1.6 Base with G3 Globe and Standard Dome Reflector
15 2624 744
25 2678 1247
35 2705 1673 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45 2250 1754 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
55 2444 2161 RC 80 70 50 30 10 0
65 2246 2192 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75 655 851 0 83 83 83 83 81 81 81 81 77 77 77 74 74 74 70 70 70 69
85 147 174 1 75 71 68 65 73 70 67 64 66 64 62 64 62 60 61 59 58 56
90 26 ZONAL LUMEN SUMMARY 2 67 61 56 51 65 60 55 51 57 53 49 54 51 48 52 49 47 45
95 6 8 ZONE LUMENS %LAMP %FIXT. 3 61 52 46 41 59 51 46 41 49 44 40 47 43 39 45 41 38 37
105 11 13 0-30 2221 13.9 19.9 4 55 46 39 34 53 45 38 34 43 37 33 41 36 33 39 35 32 30
115 73 71 0-40 3895 24.3 35.0 5 50 40 33 28 48 39 33 28 38 32 28 36 31 27 35 31 27 25
125 7 12 0-60 7809 48.8 70.1 6 46 36 29 24 44 35 29 24 34 28 24 32 27 24 31 27 23 22
135 6 3 0-90 11027 68.9 99.0 7 42 32 26 21 41 32 25 21 30 25 21 29 24 20 28 24 20 19
145 4 2 90-120 92 0.6 0.8 8 39 29 23 18 38 29 23 18 28 22 18 27 22 18 26 22 18 16
155 4 2 90-130 104 0.6 0.9 9 36 27 20 16 35 26 20 16 25 20 16 24 20 16 24 19 16 15
165 2 1 90-150 109 0.7 1.0 10 34 24 19 15 33 24 18 15 23 18 14 22 18 14 22 17 14 13
175 2 0 90-180 112 0.7 1.0
180 1 0-180 11139 69.6 100.0

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 61.0% REPORT NUMBER: KPB150LG3_AN


0.0 45.0 90.0 135.0 180.0 Flux CIE Type – Direct Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
0 1964 1964 1964 1964 1964 Spacing Base with G3 Globe and 30° Angle Reflector
5 2035 2007 1941 1871 1838 187 Plane Criteria
15 2375 2307 2140 2047 2037 619 0° 2.0
25 2755 2587 2288 2095 1853 1081 90° 1.7 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
35 2924 2763 2415 1885 1276 1416 180° 1.3 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
45 2790 2552 2015 780 518 1368 RC 80 70 50 30 10 0
55 3166 2937 1945 410 157 1520 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
65 3188 2913 777 77 0 1380 0 72 72 72 72 70 70 70 70 66 66 66 63 63 63 60 60 60 58
75 3145 2547 408 1 2 1118 1 64 60 57 54 62 58 55 53 55 53 50 52 50 48 50 48 47 45
85 2533 927 117 0 2 663 2 57 51 46 42 55 50 45 41 47 43 40 45 41 39 42 40 37 36
90 1490 640 14 5 9 ZONAL LUMEN SUMMARY 3 52 44 38 34 50 43 38 33 41 36 33 39 35 32 37 33 31 29
95 765 449 5 8 11 239 ZONE LUMENS %LAMP %FIXT. 4 47 39 33 28 45 38 32 28 36 31 27 34 30 26 32 29 26 24
105 380 163 6 11 15 106 0-30 1886 11.8 19.3 5 43 34 28 24 41 33 28 24 32 27 23 30 26 22 29 25 22 21
115 114 4 6 18 63 44 0-40 3302 20.6 33.8 6 39 31 25 20 38 30 24 20 28 24 20 27 23 19 26 22 19 18
125 2 5 7 8 7 5 0-60 6190 38.7 63.5 0-deg 7 36 28 22 18 35 27 22 18 26 21 17 25 20 17 24 20 17 15
Legend

135 2 6 7 8 6 4 0-90 9351 58.4 95.9 8 34 25 20 16 33 24 19 16 23 19 15 22 18 15 22 18 15 14


90-deg
145 0 2 6 4 2 3 90-120 389 2.4 4.0 9 32 23 18 14 30 22 17 14 21 17 14 21 16 13 20 16 13 12
155 2 4 6 6 4 2 90-130 395 2.5 4.0
180-deg 10 30 21 16 13 29 21 16 12 20 15 12 19 15 12 18 15 12 11
165 4 3 5 4 2 1 90-150 401 2.5 4.1
175 0 2 3 3 2 0 90-180 404 2.5 4.1
180 2 2 2 2 2 0-180 9754 61.0 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 973


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
250 W PSMH

* Photometric data is based on fixtures with a For candlepower values of fixtures with other
250-watt clear Pulse Start Metal Halide lamp PSMH lamps, (21,000 lumen) PSMH lamp – 0.913.
(23,000 lumen). For candlepower values of fixture with guard,
multiply by 0.95.

Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 67.4% REPORT NUMBER: KPBG250PAN


0-10 307.05 CIE Type – Direct Lamps: 250 W Metal Halide Pulse Start
10-20 986.27 Spacing Criteria: 2.16 Mogul Base
20-30 1556.63
30-40 2215.28
Lighting

40-50 2539.71 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD


50-60 2525.66 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
60-70 2313.2 RC 80 70 50 30 10 0
70-80 1992.57 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
80-90 1470.76 0 79 79 79 79 77 77 77 77 73 73 73 69 69 69 65 65 65 64
90-100 689.06 1 70 65 62 58 67 63 60 57 60 57 54 56 54 52 53 51 50 48
100-110 177.72 ZONAL LUMEN SUMMARY 2 62 55 50 45 60 54 49 44 51 46 43 48 44 41 45 42 39 38
110-120 46 ZONE LUMENS %LAMP %FIXT. 3 56 48 41 36 54 46 40 36 44 39 34 41 37 33 39 35 32 30
120-130 10.39 0-30 2849.95 11.4 16.9 4 51 42 35 30 49 41 34 29 38 33 29 36 31 28 34 30 27 25
Lighting: Enclosed and Gasketed — Area — HID

130-140 6.24 0-40 5065.22 20.3 30.1 5 47 37 30 25 45 36 30 25 34 28 24 32 27 23 30 26 23 21


140-150 5.71 0-60 10130.59 40.5 60.1 6 43 33 26 21 41 32 26 21 30 25 21 29 24 20 27 23 20 18
150-160 3.95 0-90 15907 63.6 94.4 7 40 30 23 19 38 29 23 18 27 22 18 26 21 18 25 20 17 16
160-170 2.26 90-120 912.78 3.7 5.4 8 37 27 21 16 35 26 20 16 25 20 16 24 19 16 23 18 15 14
170-180 .8 90-130 923.17 3.7 5.5 9 34 24 19 15 33 24 18 14 23 18 14 22 17 14 21 17 14 12
90-150 935.11 3.7 5.5 10 32 22 17 13 31 22 17 13 21 16 13 20 16 12 19 15 12 11
90-180 942.12 3.8 5.6
0-180 16849.24 67.4 100.0

Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 72.6% REPORT NUMBER: KPBG250PST


0-10 382.83 CIE Type – Direct Lamps: 250 W Metal Halide Pulse Start
10-20 1200.76 Spacing Criteria: 1.58 Mogul Base
20-30 1987.77
30-40 2662.58
40-50 3136.15 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
50-60 3436.26 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
60-70 3412.32 RC 80 70 50 30 10 0
70-80 1660.08 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
80-90 278.17 0 86 86 86 86 84 84 84 84 81 81 81 77 77 77 74 74 74 73
90-100 3.43 1 78 74 71 68 76 73 70 67 70 67 65 67 65 63 64 62 61 59
100-110 0 ZONAL LUMEN SUMMARY 2 70 63 58 53 68 62 57 53 59 55 51 57 53 50 55 52 49 47
110-120 0 ZONE LUMENS %LAMP %FIXT. 3 63 55 48 43 61 53 47 42 51 46 42 49 45 41 47 43 40 38
120-130 0 0-30 3571.36 14.3 19.7 4 57 48 41 35 55 47 40 35 45 39 34 43 38 34 41 37 33 32
130-140 0 0-40 6233.94 24.9 34.3 5 52 42 35 30 50 41 34 29 39 34 29 38 33 29 37 32 28 27
140-150 0 0-60 12806.35 51.2 70.5 6 48 37 30 25 46 37 30 25 35 29 25 34 29 25 33 28 24 23
150-160 0 0-90 18156.91 72.6 100 7 44 33 27 22 43 33 26 22 32 26 22 31 25 21 30 25 21 20
160-170 0 90-120 3.43 0 0 8 41 30 24 19 40 30 23 19 29 23 19 28 23 19 27 22 19 17
170-180 0 90-130 3.43 0 0 9 38 28 21 17 37 27 21 17 26 21 17 25 20 17 25 20 17 15
90-150 3.43 0 0 10 35 25 19 15 35 25 19 15 24 19 15 23 18 15 23 18 15 14
90-180 3.43 0 0
0-180 18160.34. 72.6 100.0

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 85.5% REPORT NUMBER: KPBG250PG


Zone CIE Type – General Diffuse Lamps: 250 W Metal Halide Pulse Start
0-10 74.54 Mogul Base
10-20 304.58
20-30 486.47
30-40 948.61 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
40-50 1471.61 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
50-60 1887.31 RC 80 70 50 30 10 0
60-70 2239.17 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 2561.7 0 94 94 94 94 87 87 87 87 76 76 76 65 65 65 55 55 55 51
80-90 2747.67 1 80 74 68 63 74 68 63 59 58 54 51 49 46 43 40 38 36 31
90-100 2779.02 2 71 61 54 47 65 57 50 44 48 42 38 40 36 32 32 29 26 22
100-110 2564.95 ZONAL LUMEN SUMMARY 3 63 52 44 37 58 48 41 34 41 34 29 33 29 25 27 23 20 16
110-120 2148.15 ZONE LUMENS %LAMP %FIXT. 4 57 45 36 30 52 42 34 28 35 29 24 29 24 20 23 19 16 13
120-130 1109.49 0-30 865.59 3.5 4.1 5 52 40 31 25 47 36 29 23 31 24 19 25 20 16 20 16 13 10
130-140 37.55 0-40 1814.2 7.3 8.5 6 47 35 27 21 43 32 25 19 27 21 16 22 17 13 18 14 11 8
140-150 3.93 0-60 5173.13 20.7 24.2 7 44 31 23 18 40 29 22 16 24 18 14 20 15 11 16 12 9 7
150-160 .76 0-90 12721.67 50.9 59.5 8 40 28 20 15 37 26 19 14 22 16 12 18 13 10 15 11 8 6
160-170 .09 90-120 7492.124 30 35.1 9 37 25 18 13 34 24 17 12 20 14 10 17 12 9 13 10 7 5
170-180 .03 90-130 8601.61 34.4 40.3 10 35 23 16 12 32 22 15 11 18 13 9 15 11 8 12 9 6 4
90-150 8643.09 34.6 40.5
90-180 8643.97 34.6 40.5
0-180 21365.63 85.5 100.0

974 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
250 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on fixtures with a For candlepower values of fixtures with other
250-watt clear Pulse Start Metal Halide lamp PSMH lamps, (21,000 lumen) PSMH lamp – 0.913.
(23,000 lumen). For candlepower values of fixture with guard,
multiply by 0.95.

Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 79% REPORT NUMBER: KPBR250PJ3


0-10 28.46 CIE Type – Semi-Direct Lamps: 250 W Metal Halide Pulse Start
10-20 222.99 Spacing Criteria: 1.64 Mogul Base
20-30 438.39
30-40 727.7
40-50 1709.75 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

Lighting
50-60 2094.28 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
60-70 4828.69 RC 80 70 50 30 10 0
70-80 4189.12 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
80-90 2131.34 0 91 91 91 91 87 87 87 87 80 80 80 74 74 74 68 68 68 65
90-100 748.43 1 77 70 65 60 73 67 62 57 61 57 53 55 52 49 50 48 45 42
100-110 1109.54 ZONAL LUMEN SUMMARY 2 66 56 48 42 62 54 46 40 48 42 37 43 38 34 39 35 31 28
110-120 701.88 ZONE LUMENS %LAMP %FIXT. 3 58 46 37 30 55 44 36 29 39 32 27 35 29 24 31 26 22 19
120-130 410.51 0-30 689.84 2.8 3.5 4 52 39 30 23 49 37 29 22 33 26 20 30 23 18 26 21 17 14
130-140 237.73 0-40 1417.54 5.7 7.2 5 47 34 25 18 44 32 24 17 29 21 16 25 19 14 22 17 13 10

Lighting: Enclosed and Gasketed — Area — HID


140-150 123.53 0-60 5221.56 20.9 26.4 6 43 30 21 15 40 28 20 14 25 18 13 22 16 12 20 14 10 8
150-160 37.79 0-90 16370.71 65.5 82.9 7 39 26 18 12 37 25 17 12 22 16 11 20 14 9 18 12 8 6
160-170 3.51 90-120 2559.84 10.2 13 8 36 24 16 10 34 22 15 10 20 14 9 18 12 8 16 11 7 5
170-180 .32 90-130 2970.35 11.9 15 9 33 21 14 9 32 20 13 8 18 12 8 16 11 7 15 10 6 4
90-150 3331.61 13.3 16.9 10 31 19 12 8 29 18 12 7 17 11 7 15 10 6 13 9 5 4
90-180 3373.23 13.5 17.1
0-180 19743.94 79 100.0

Zone Lumens TOTAL LUMINAIRE EFFICIENCY = 84% REPORT NUMBER: KPBR250PJ5


0-10 28.96 CIE Type – Semi-Direct Lamps: 250 W Metal Halide Pulse Start
10-20 214.01 Spacing Criteria: 1.64 Mogul Base
20-30 402.91
30-40 678.83
40-50 1539.03 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
50-60 1537.39 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
60-70 4450.44 RC 80 70 50 30 10 0
70-80 5789.28 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
80-90 3160.26 0 97 97 97 97 93 93 93 93 86 86 86 80 80 80 74 74 74 71
90-100 855.15 1 80 72 66 60 76 69 63 57 63 58 53 57 53 49 52 48 45 42
100-110 1095.13 ZONAL LUMEN SUMMARY 2 68 57 48 40 65 54 46 38 49 42 35 44 38 33 39 34 30 27
110-120 596.59 ZONE LUMENS %LAMP %FIXT. 3 60 47 37 29 56 44 35 27 40 32 25 35 29 23 31 26 21 18
120-130 345.11 0-30 645.89 2.6 3.1 4 54 40 29 22 50 37 28 21 33 25 19 30 23 17 26 20 15 13
130-140 189.6 0-40 1324.72 5.3 6.3 5 48 34 24 17 45 32 23 16 29 21 15 26 19 13 23 17 12 9
140-150 82.84 0-60 4401.15 17.6 21 6 44 30 21 14 41 28 20 13 25 18 12 23 16 11 20 14 10 7
150-160 22.91 0-90 17801.14 71.2 84.8 7 41 27 18 11 38 25 17 11 23 15 10 20 14 9 18 12 8 6
160-170 2.78 90-120 2546.87 10.2 12.1 8 38 24 16 10 35 23 15 9 21 14 8 18 12 8 16 11 7 5
170-180 .71 90-130 2891.98 11.6 13.8 9 35 22 14 8 33 21 13 8 19 12 7 17 11 7 15 10 6 4
90-150 3164.41 12.7 15.1 10 33 20 12 7 31 19 12 7 17 11 6 16 10 6 14 9 5 3
90-180 3190.80 12.8 15.2
0-180 20991.94 84 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 975


© September 2010
Mercmaster™ III 400 Luminaire for Hazardous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other areas
where flammable gases and vapors or combustible dusts are
Lighting

present under conditions defined by the National Electrical


Code as Class I, Division 2; Class II, Division 1 and 2; and
Class III
— In ap­pli­ca­tions in­volv­ing me­di­um and high mount­ing heights
— In ap­pli­ca­tions where en­er­gy ef­fi­cient, high lu­men out­put is
required
— The AEx nA nR Mercmaster III fixture is factory sealed and
prevents vapors and gases from entering the globe chamber. Enclosed Reflector Prismatic Glass Globe 12” Glass Refractor
Lighting: Enclosed and Gasketed — Area — HID

There are no seals or putty required.


— The AEx nR Mercmaster III fixture requires all wiring entries to
be sealed. • One-piece bal­last hous­ing for each com­po­nent pro­vides even
— Non-hazardous locations where severe weather conditions, heat dis­si­pa­tion for cool­er op­er­a­tion and long­er bal­last life.
excessive moisture, dirt, dust, corrosive atmosphere or high • All Mercmaster mount­ing hoods have pro­vi­sion for easy field in­
ambient temperatures are encountered stal­la­tion of fus­es in fix­tures (see fuse kit list­ings).
• Typical applications include: Standard Materials
— Pulp and paper mills
— Processing plants • Mounting hoods and bal­last bod­ies: cast copperfree (less than
— Chemical plants 4/10 of 1% cop­per) alu­mi­num
— Oil refineries • Reflectors: Fiberglass reinforced white poly­es­ter
— Foundries • Guards, hard­ware and catch as­sem­blies: stain­less steel
— Manufacturing plants • Globe: heat- and im­pact-re­sist­ant in­ter­nal­ly flut­ed glass
— Storage areas • Refractors: pris­mat­ic glass
— Waste and sew­age treat­ment • Enclosed re­flec­tor: etched Alzak alu­mi­num with sealed, tem­pered
— Oth­er ar­e­as where dust, wa­ter, dirt and rough us­age are a heat- and im­pact-re­sist­ant lens
prob­lem • Body and globe gaskets: high-temperature silicone rubber

Features Standard Finishes


• Superior cor­ro­sion re­sis­tance. • Mounting hoods and guards: ep­oxy pow­der coat, elec­tro­stat­i­cal­ly
• Choice of light sourc­es: high pres­sure so­di­um, and pulse start ap­plied for com­plete and uni­form pro­tec­tion
metal halide. Options
• Six mount­ing ar­range­ments to suit any light­ing lay­out: pen­dant, • AEx nA nR fixtures are available with a Class I, Zone 2 rating. Add
ceil­ing, wall brack­et, 25° (an­gle) stan­chion, 90° (straight) suffix -Z2.
stan­chion and cone. • AEx nR fixtures are available with a Class I, Zone 2 rating. Add
• Hinge has high lip for add­ed safe­ty dur­ing in­stal­la­tion and suffix -ZB.
ser­vic­ing. Hinge and bolt con­struc­tion as­sures 360º com­pres­sion • Ex nR fixtures are available with a Class I, Zone 2 rating. Add
at all points on bal­last hous­ing gas­ket for pos­i­tive seal­ing. Swing suffix -Z V.
away de­sign of cap­tive bolt and nut sim­pli­fies ser­vic­ing. • Quartz Auxiliary comes to full bright­ness im­me­di­ate­ly and
• Choice of op­ti­cal as­sem­blies: pris­mat­ic globe; en­closed re­flec­ re­mains lit un­til the HID lamp at­tains 60-70% of full il­lu­mi­na­tion.
tor with sealed lens; or Type V or Type II closed pris­mat­ic glass Quartz Auxiliary sup­plied with re­lay switch and sock­et to ac­cept
re­frac­tor, with or with­out guards. 120V quartz dou­ble-con­tact bay­o­net base lamp (not in­clud­ed).
• Wide choice of pho­to­met­ric dis­tri­bu­tions. (Not suit­a­ble for haz­ard­ous lo­ca­tions.) Add suf­fix -E.
• All fix­tures de­signed to per­form in a 104 ºF/40 ºC am­bi­ent tem­per­ • Factory sealed photocontrol available. See PCD2 Series.
a­ture. Selected fix­tures are suit­a­ble for am­bi­ent tem­per­a­tures up • Smart Starter incorporates a 1-1/2-minute timer and performs
to 149 ºF/65 ºC. as a conventional starter to normally start lamp. Removes
• Mogul base porcelain lamp holder with nickel-plated contacts itself from circuit if lamp burns out or is removed from socket.
has 392 °F/200 °C rated welded leads, pre-wired to the ballast. Eliminates starter failures caused by prolonged operation with
Assures trouble-free operation in installations where high ambient cycling or failing lamps and simplifies finding their location,
temperatures are encountered. reducing maintenance and repair costs. Available for all HPS
• For electrical protection, a ground wire is provided on each and PSMH fixtures. Add suffix -S.
Mercmaster to bond hood and ballast housing.
• Terminal blocks are provided for Zone 2 fixtures to facilitate wiring. Certifications and Compliances
• Standard dome of 30º an­gle re­flec­tors made of fi­ber­glass re­in­ • UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
forced white poly­es­ter. Highly re­sist­ant to cor­ro­sive at­mos­pheres. 60079-15
• A wide range of voltages available (120 to 600 Volt) and ballast • UL Listed: E10444
types (CWA, CWI and Super CWA).

V CSA Certification only.

976 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Illustrated Features

Lighting
Vented Reflectors

Lighting: Enclosed and Gasketed — Area — HID


Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Ballast Assembly
High Temperature Sockets Terminal Blocks (Zone 2) Utilizing non-sparking components
Mogul base high-temperature porcelain A seven-point terminal block is provided avoiding the ignition of gases or vapors
sockets. to facilitate wiring. Terminal block that may be present (nA).
accommodates wire size ranging from #8
Aluminum Inner Reflector to #24 AWG. Mounting Hood and Globe Gaskets
Solid aluminum inner reflector (for Silicone rubber gasket seals out moisture,
refractor ballast housings only) improves Stainless Steel Inserts dirt and dust. Stays flexible, withstands
photometric efficiency. Ballast bodies have stainless steel high temperatures. Closure design
threaded inserts to receive stainless steel assures uniform gasket compression.
Globe Chamber screws for reflectors and guard. Prevents
Completely sealed from the ballast "freezing”, allowing guards and reflectors Electrical Protection
housing and outside vapors/air (nR). to be easily removed and replaced at any Ground wire provided to bond mounting
time, without damage to the housing. hood to ballast housing.

"Safety" High Epoxy Finish


Hinge Ballast housing, hoods and guards are
Extra-high hinge copperfree aluminum with epoxy powder
provides additional coat finish.
protection against
accidental Photocell
ballast housing Available for all fixtures except cone and
disengagement ceiling mount. Installs through knock-out
during installation in mounting hood. Provides continuous
or maintenance. ON-OFF dusk-to-dawn control.
Cooler Operating Cone Hood
Prismatic Glass Globes, Refractors Larger sloped surface sheds dusts, dirt
and Enclosed Reflector and combustible fibers providing better
Stainless Steel Heat-resistant globes, refractors and heat dissipation.
Latch Assembly enclosed reflector thread into ballast
Captive, stainless housing and seal against a high
steel latch assembly temperature silicone rubber gasket.
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 977


© September 2010
Mercmaster™ III 400 Luminaires for Hazerdous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Order using catalog numbering guide below or select catalog number from tables on following pages.

Catalog Numbering Guide


KP A L 40 10 J5 G MT S Z2
Lighting

Series: Lamp Type: Hub Size: Guard Options: ➋ Options:


KP - L - High Pressure 75 - 3/4” NPT G - Globe Guard E - Emergency Quartz
Mercmaster III Sodium 10 - 1” NPT BG - Refractor F - Fuse Kit (Specify
400 P - Pulse Start 125 - 1-1/4” NPT Guard Voltage)
Metal Halide stanchion NG - Enclosed S - Smart Starter
150 - 1-1/2” NPT Relfector Guard H1 - Photocontrol 120 V
stanchion Blank - No Guard H2 - Photocontrol 208 V
Lighting: Enclosed and Gasketed — Area — HID

H3 - Photocontrol 240 V
H4 - Photocontrol 277 V
C - Safety Cable
Adapted V
E40 - Export Socket
D - E-40 Export
Socket V
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➏
Mounting Hood
Adapter V

Mounting: Wattage: Optical Assembly: ➊ Voltage: ➌ Suffix:


A - Pendant (rigid 25 - 250 W HPS, PSMH ➎ Blank - Glass Globe MT - 120/208/240/277, Z2 - Zone 2 suffix
mounting) 32 - 320 W PSMH J2 - NEMA II Glass 60Hz (required for
C - Ceiling 35 - 350 W PSMH Refractor ➍ 5MT - 120/208/240/ AEx nA nR
CH - Pendant Cone Hood 40 - 400 W PSMH & HPS J5 - NEMA V Glass 277/480, 60Hz rating)
48 - 480, 60Hz
F - Pendant (flexible 40 - 400 W MH V Refractor ➍ 125 - 120, 50Hz ZB - Zone 2 suffix
mounting) R - Enclosed Refractor 226 - 220, 60Hz (required for
ST - 90° Stanchion with Sealed Lens 235 - 230, 50Hz AEx nR rating)
S - 25° Stanchion 245 - 240, 50 Hz Z - Zone 2 suffix
WB- Wall C2 - 208, 60 Hz, CWI V (required for
C3 - 240, 60 Hz, CWI V Ex nR) V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V

Refer to “Mounting Hoods and Ballast” page for available Voltage Configuration.
 NO DESIGNATION is required for fixtures with standard type globe.
 NO DESIGNATION is required for fixtures without guards.
➌ Other voltages available. Contact your local sales representative.
➍ J2 and J5 refractions are not available with Z2 or ZB suffix.
➎ Available for 480 V, 50 Hz and 5MT ballast options. For MT and TT voltage suffix, see Mercmaster III 50-250 Luminaries.
➏ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification only.

978 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions on Both Classifications
Temperature identification numbers of Mercmaster III – 400 Fixtures.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

“T” Numbers
Class II, Division 1 Simultaneous Exposure
Lamp Supply Class I, Division 2 Groups E, F and G Class I, Division 2 / Class II, Division 1
Wire Ambient

Lighting
Temp. Temp. Globe & Enclosed Globe & Enclosed Globe & Enclosed
Watts Type (°F/°C) ➊ (°F/°C) ➊ Globe Reflector Refractor Reflector Globe Reflector Refractor Reflector Globe Reflector Refractor Reflector
230/110 104/40 T2 T2 T2 T2 T3B T3B T4 T4A 325 325 325 325
250 HPS 230/110 131/55 325 325 T2 T2 — — T3B T4A — — T1 325
230/110 149/65 — — T2 T2 — — T3B T4 — — T1 350
400 HPS 194/90 104/40 350 T1 T1 350 T3 * T3 * T3C T3C T1 T1 T1 350

Lighting: Enclosed and Gasketed — Area — HID


194/90 104/40 T2B T2B T2B T2C T3 (EF) T3 (EF) T4 T4A — — — —
250 PSMH 194/90 131/55 T2A T2A T2B T2C — — — — — — — —
194/90 149/65 — — — T2C — — — — — — — —
194/90 104/40 T2B T2B T2B T2B — — T3C T3C — — — —
320 PSMH
194/90 131/55 T2A T2A T2A T2B — — — — — — — —
194/90 104/40 T2B T2B T2B T2B — — T3C T3C — — — —
350 PSMH
194/90 131/55 T2A T2A T2A T2B — — — — — — — —
400 PSMH 194/90 104/40 T2A T2A T2B T2B — — T3C T3C — — — —
400 MH V 194/90 104/40 T2 T2 T2A T2A — — T3A T4 — — — —

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(ºC)

➊ “T” numbers are for Groups E and F only.


V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 979


© September 2010
Mercmaster™ III 400 Luminaire Thermal Performance
Class I, Zone 2, AEx nR IIC, AEx nA nR IIC, IP66, NEMA 4X
Temperature identification numbers of Mercmaster III – 400 Fixtures.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

“T” Numbers

Lamp Supply Class 1, Zone 2 AEx nA nR / Ex nR Class 1, Zone 2 AEx nR


Wire Ambient
Temp. Temp. Globe & Enclosed Globe & Enclosed
Lighting

Watts Type (°F/°C) ➊ (°F/°C) ➊ Globe Reflector Reflector Globe Reflector Reflector
HPS 230/110 104/40 T4 T4 T5 T4 T4 T5
250 HPS 230/110 131/55 T3 T3 T3 T3 T3 T3
HPS 230/110 149/65 — — T3 — — T3
400 HPS 194/90 104/40 T4 T4 T5 T4 T4 T5
T3 T3 T3
Lighting: Enclosed and Gasketed — Area — HID

PSMH 194/90 104/40 — — —


250 PSMH 194/90 131/55 T3 T3 T3 — — —
PSMH 194/90 104/40 — — T3 — — —
PSMH 194/90 104/40 T4 T4 T4 T4 T4 T4
320
PSMH 194/90 131/55 T3 T3 T4 T3 T3 T4
PSMH 194/90 104/40 T4 T4 T4 T4 T4 T4
350
PSMH 194/90 131/55 T3 T3 T4 T3 T3 T4
400 PSMH 167/75 104/40 T3 T3 T3 T3 T3 T3
400 MH V 167/75 104/40 T3 T3 T3 — — —

“T” Numbers represent the maximum surface temperature for luminaries with AEx nA nR and AEx nR rating:
To comply with AEx nR Requirements, all wiring entries must be sealed.

“T”
T1 T2 T3 T4 T5 T6
Number

Temp. 547-842 394-572 277-392 214-275 187-212 185


Range (°F)

Temp. 301-450 201-300 136-200 101-135 86-100 85


Range (°C)

➊ Use 194 °F/90 °C rated supply wire.


V CSA Certification only.

980 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaires for Hazerdous and Wet Locations
250 W, 400 W HPS
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Type Lamp Lamp Hub Size Catalog Numbers ➎


Mounting Type Watts (Inches) With Globe With Type V 12” Refractor  With Enclosed Reflector
Pendant — One Hub, Rigid Mounting 

Lighting
3/4 KPAL2575 KPAL2575J5 KPAL2575R
HPS 250
1 KPAL2510 KPAL2510J5 KPAL2510R
3/4 KPAL4075 KPAL4075J5 KPAL4075R
HPS 400
1 KPAL4010 KPAL4010J5 KPAL4010R

Lighting: Enclosed and Gasketed — Area — HID


Shown with Globe
Pendant Cone — One Hub, Rigid Mounting
3/4 KPCHL2575 KPCHL2575J5 KPCHL2575R
HPS 250
1 KPCHL2510 KPCHL2510J5 KPCHL2510R
3/4 KPCHL4075 KPCHL4075J5 KPCHL4075R
HPS 400
1 KPCHL4010 KPCHL4010J5 KPCHL4010R

Shown with 12" Glass Refractor


Ceiling — Five Hubs, Four Close-Up Plugs
3/4 KPCL2575 KPCL2575J5 KPCL2575R
HPS 250
1 KPCL2510 KPCL2510J5 KPCL2510R
3/4 KPCL4075 KPCL4075J5 KPCL4075R
HPS 400
1 KPCL4010 KPCL4010J5 KPCL4010R

Shown with Enclosed Reflector

 For Flexible Pendant Mount, change A to F in catalog number.


 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 250 X X X X — X X — — — — — X
HPS 400 X X X X — — X — — — — — X
PSMH 250 — X X X — — X — — — — — —
PSMH 320 X X X X — — X — — — — — X
PSMH 350 X X X X — — X — — — — — X
PSMH 400 X X X — — — X — — — — — X
MH V 400 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 981


© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 400 W HPS
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Type Lamp Lamp Hub Size Catalog Numbers ➎


Mounting Type Watts (Inches) With Globe With Type V 12” Refractor  With Enclosed Reflector
Wall Five Hubs, Four Close-Up Plugs
3/4 KPWBL2575 KPWBL2575J5 KPWBL2575R
Lighting

HPS 250
1 KPWBL2510 KPWBL2510J5 KPWBL2510R
3/4 KPWBL4075 KPWBL4075J5 KPWBL4075R
HPS 400
1 KPWBL4010 KPWBL4010J5 KPWBL4010R
Lighting: Enclosed and Gasketed — Area — HID

Shown with 12” Glass Refractor


25° Stanchion One Hub
1-1/4 KPSL25125 KPSL25125J5 KPSL25125R
HPS 250
1-1/2 KPSL25150 KPSL25150J5 KPSL25150R
1-1/4 KPSL40125 KPSL40125J5 KPSL40125R
HPS 400
1-1/2 KPSL40150 KPSL40150J5 KPSL40150R

Shown with Prismatic Glass Globe


and Optional Guard
90° Stanchion One Hub
1-1/4 KPSTL25125 KPSTL25125J5 KPSTL25125R
HPS 250
1-1/2 KPSTL25150 KPSTL25150J5 KPSTL25150R
1-1/4 KPSTL40125 KPSTL40125J5 KPSTL40125R
HPS 400
1-1/2 KPSTL40150 KPSTL40150J5 KPSTL40150R

Shown with Prismatic Glass Globe


and Optional Guard

 For Flexible Pendant Mount, change A to F in catalog number.


 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 250 X X X X — X X — — — — — X
HPS 400 X X X X — — X — — — — — X
PSMH 250 — X X X — — X — — — — — —
PSMH 320 X X X X — — X — — — — — X
PSMH 350 X X X X — — X — — — — — X
PSMH 400 X X X — — — X — — — — — X
MH V 400 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

982 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 320 W, 350 W, 400 W PSMH
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Type Lamp Lamp Hub Size Catalog Numbers ➎


Mounting Type Watts (Inches) With Globe With Type V 12” Refractor  With Enclosed Reflector
Pendant One Hub, Rigid Mounting 
3/4 KPAP2575 KPAP2575J5 KPAP2575R

Lighting
PSMH 250 ➐
1 KPAP2510 KPAP2510J5 KPAP2510R
3/4 KPAP3275 KPAP3275J5 KPAP3275R
PSMH 320
1 KPAP3210 KPAP3210J5 KPAP3210R
3/4 KPAP3575 KPAP3575J5 KPAP3575R
PSMH 350
1 KPAP3510 KPAP3510J5 KPAP3510R

Lighting: Enclosed and Gasketed — Area — HID


3/4 KPAP4075 KPAP4075J5 KPAP4075R
PSMH 400
Shown with Globe 1 KPAP4010 KPAP4010J5 KPAP4010R
Pendant Cone One Hub, Rigid Mounting
3/4 KPCHP2575 KPCHP2575J5 KPCHP2575R
PSMH 250 ➐
1 KPCHP2510 KPCHP2510J5 KPCHP2510R
3/4 KPCHP3275 KPCHP3275J5 KPCHP3275R
PSMH 320
1 KPCHP3210 KPCHP3210J5 KPCHP3210R
3/4 KPCHP3575 KPCHP3575J5 KPCHP3575R
PSMH 350
1 KPCHP3510 KPCHP3510J5 KPCHP3510R
3/4 KPCHP4075 KPCHP4075J5 KPCHP4075R
Shown with 12" Glass Refractor PSMH 400
1 KPCHP4010 KPCHP4010J5 KPCHP4010R
Ceiling Five Hubs, Four Close-Up Plugs
3/4 KPCP2575 KPCP2575J5 KPCP2575R
PSMH 250 ➐
1 KPCP2510 KPCP2510J5 KPCP2510R
3/4 KPCP3275 KPCP3275J5 KPCP3275R
PSMH 320
1 KPCP3210 KPCP3210J5 KPCP3210R
3/4 KPCP3575 KPCP3575J5 KPCP3575R
PSMH 350
1 KPCP3510 KPCP3510J5 KPCP3510R
3/4 KPCP4075 KPCP4075J5 KPCP4075R
PSMH 400
Shown with Enclosed Refractor 1 KPCP4010 KPCP4010J5 KPCP4010R

 For Flexible Pendant Mount, change A to F in catalog number.


 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 250 X X X X — X X — — — — — X
HPS 400 X X X X — — X — — — — — X
PSMH 250 — X X X — — X — — — — — —
PSMH 320 X X X X — — X — — — — — X
PSMH 350 X X X X — — X — — — — — X
PSMH 400 X X X — — — X — — — — — X
MH V 400 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 983


© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 320 W, 350 W, 400 W PSMH
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Type Lamp Lamp Hub Size Catalog Numbers ➎


Mounting Type Watts (Inches) With Globe With Type V 12” Refractor  With Enclosed Reflector
Wall Five Hubs, Four Close-Up Plugs
3/4 KPWBP2575 KPWBP2575J5 KPWBP2575R
Lighting

PSMH 250 ➐
1 KPWBP2510 KPWBP2510J5 KPWBP2510R
3/4 KPWBP3275 KPWBP3275J5 KPWBP3275R
PSMH 320
1 KPWBP3210 KPWBP3210J5 KPWBP3210R
3/4 KPWBP3575 KPWBP3575J5 KPWBP3575R
PSMH 350
1 KPWBP3510 KPWBP3510J5 KPWBP3510R
Lighting: Enclosed and Gasketed — Area — HID

3/4 KPWBP4075 KPWBP4075J5 KPWBP4075R


PSMH 400
Shown with 12” Glass Refractor 1 KPWBP4010 KPWBP4010J5 KPWBP4010R
25° Stanchion One Hub
1-1/4 KPSP25125 KPSP25125J5 KPSP25125R
PSMH 250 ➐
1-1/2 KPSP25150 KPSP25150J5 KPSP25150R
1-1/4 KPSP32125 KPSP32125J5 KPSP32125R
PSMH 320
1-1/2 KPSP32150 KPSP32150J5 KPSP32150R
1-1/4 KPSP35125 KPSP35125J5 KPSP35125R
PSMH 350
1-1/2 KPSP35150 KPSP35150J5 KPSP35150R
1-1/4 KPSP40125 KPSP40125J5 KPSP40125R
Shown with Prismatic Glass Globe PSMH 400
and Optional Guard 1-1/2 KPSP40150 KPSP40150J5 KPSP40150R
90° Stanchion One Hub
1-1/4 KPSTP25125 KPSTP25125J5 KPSTP25125R
PSMH 250 ➐
1-1/2 KPSTP25150 KPSTP25150J5 KPSTP25150R
1-1/4 KPSTP32125 KPSTP32125J5 KPSTP32125R
PSMH 320
1-1/2 KPSTP32150 KPSTP32150J5 KPSTP32150R
1-1/4 KPSTP35125 KPSTP35125J5 KPSTP35125R
PSMH 350
1-1/2 KPSTP35150 KPSTP35150J5 KPSTP35150R
1-1/4 KPSTP40125 KPSTP40125J5 KPSTP40125R
Shown with Prismatic Glass Globe PSMH 400
and Optional Guard 1-1/2 KPSTP40150 KPSTP40150J5 KPSTP40150R

 For Flexible Pendant Mount, change A to F in catalog number.


 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 250 X X X X — X X — — — — — X
HPS 400 X X X X — — X — — — — — X
PSMH 250 — X X X — — X — — — — — —
PSMH 320 X X X X — — X — — — — — X
PSMH 350 X X X X — — X — — — — — X
PSMH 400 X X X — — — X — — — — — X
MH V 400 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

984 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
400 W MH V
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Type Lamp Lamp Hub Size Catalog Numbers ➎


Mounting Type Watts (Inches) With Globe With Type V 12” Refractor  With Enclosed Reflector
Pendant One Hub, Rigid Mounting 

Lighting
3/4 KPAH4075 KPAH4075J5 KPAH4075R
MH V 400
1 KPAH4010 KPAH4010J5 KPAH4010R

Lighting: Enclosed and Gasketed — Area — HID


Shown with Globe
Pendant Cone One Hub, Rigid Mounting

3/4 KPCHH4075 KPCHH4075J5 KPCHH4075R


MH V 400
1 KPCHH4010 KPCHH4010J5 KPCHH4010R

Shown with 12" Glass Refractor


Ceiling Five Hubs, Four Close-Up Plugs

3/4 KPCH4075 KPCH4075J5 KPCH4075R


MH V 400
1 KPCH4010 KPCH4010J5 KPCH4010R

Shown with Enclosed Refractor

 For Flexible Pendant Mount, change A to F in catalog number.


 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 250 X X X X — X X — — — — — X
HPS 400 X X X X — — X — — — — — X
PSMH 250 — X X X — — X — — — — — —
PSMH 320 X X X X — — X — — — — — X
PSMH 350 X X X X — — X — — — — — X
PSMH 400 X X X — — — X — — — — — X
MH V 400 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ Available for 480 V, 50 Hz and 5MT ballast options. For MT and TT voltage suffix, see Mercmaster III 50-250 Luminaries.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 985


© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
400 W MH V
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Type Lamp Lamp Hub Size Catalog Numbers ➎


Mounting Type Watts (Inches) With Globe With Type V 12” Refractor  With Enclosed Reflector
Wall Five Hubs, Four Close-Up Plugs
Lighting

3/4 KPWBH4075 KPWBH4075J5 KPWBH4075R


MH V 400
1 KPWBH4010 KPWBH4010J5 KPWBH4010R
Lighting: Enclosed and Gasketed — Area — HID

Shown with 12” Glass Refractor


25° Stanchion One Hub

1-1/4 KPSH40125 KPSH40125J5 KPSH40125R


MH V 400
1-1/2 KPSH40150 KPSH40150J5 KPSH40150R

Shown with Prismatic Glass Globe


and Optional Guard
90° Stanchion One Hub

1-1/4 KPSTH40125 KPSTH40125J5 KPSTH40125R


MH V 400
1-1/2 KPSTH40150 KPSTH40150J5 KPSTH40150R

Shown with Prismatic Glass Globe


and Optional Guard

 For Flexible Pendant Mount, change A to F in catalog number.


 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 250 X X X X — X X — — — — — X
HPS 400 X X X X — — X — — — — — X
PSMH 250 — X X X — — X — — — — — —
PSMH 320 X X X X — — X — — — — — X
PSMH 350 X X X X — — X — — — — — X
PSMH 400 X X X — — — X — — — — — X
MH V 400 X — — X X — — X X X X X X
Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

986 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaire Mounting Hood and Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Mounting Hoods
Description Hub Size (Inches) Catalog Number
Pendant
3/4 KPA-75
One Hub, Rigid Mounting

Lighting
1 KPA-100
Pendant — Flexible
3/4 KPAF-75
One Hub, Flexible Mounting
1 KPAF-100
Pendant Cone
3/4 KPCH-75

Lighting: Enclosed and Gasketed — Area — HID


One Hub, Rigid
1 KPCH-100
Ceiling
3/4 KPC-75
Five Hubs, Four Close-Up Plugs
1 KPC-100
Wall
3/4 KPWB-75
Five Hubs, Four Close-Up Plugs
1 KPWB-100
25° Stanchion
1-1/4 KPS-125
One Hub
1-1/2 KPS-150

90° Stanchion
1-1/4 KPST-125
One Hub
1-1/2 KPST-150

Ballast Bodies

High Pressure Sodium — Constant Wattage (Min. P.F. 90%)


Pulse Start Metal Halide — Super Constant Wattage (Min. P.F. 90%)

Lamp Lamp Catalog Voltage Suffixes


Type Watts Numbers ➋➍ MT 5MT 48 125 225 226 235 245 C2 V C3 V C6 V C7 V TT V
HPS 250 KPB250L ➊➌ X X X X — X X — — — — — X
HPS 400 KPB400L ➊➌ X X X X — — X — — — — — X
PSMH 250 KPB250P ➊➌ — X X X — — X — — — — — X
PSMH 320 KPB320P ➊➌ X X X X — — X — — — — — X
PSMH 350 KPB350P ➊➌ X X X X — — X — — — — — X
PSMH 400 KPB400P ➊➌ X X X — — — X — — — — — X
MH V 400 KPB400H X — — X X — — X X X X X X

Voltages: 125 - 120 V 50 Hz 245 - 240 V 50 Hz


MT - 120/208/240/277 V 60 Hz 225 - 225 V 50 Hz C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz 226 - 220 V 60 Hz C3 - 240 V 60 Hz, CWI V C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz 235 - 230 V 50 Hz C6 - 480 V 60 Hz, CWI V TT - 120/277/347 V 60 Hz, CWA V

➊ Add -S after voltage designation for ballast body with Smart Starter (HPS and PSMH only).
➋ Add -E after voltage designation for ballast body with provision for Quartz Emergency Light (not suitable for hazardous location).
➌ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➍ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 987


© September 2010
Mercmaster™ III 400 Luminaire Optics and Accessories
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Description Catalog Number


Prismatic Glass Globes — Heat-Resistant
Lighting

Clear VPGL-4HR

Glass Globe
Enclosed Reflector Assembly
Lighting: Enclosed and Gasketed — Area — HID

Heat- and impact-resistant glass lens KPR-4HB

Enclosed Reflector
Light Distribution IES/NEMA Distribution Curves Catalog Number
Closed Prismatic Glass Refractors ➌ — All Heat-Resistant

NEMA Type II KPRF400-2

NEMA Type V KPRF400-5

Glass Refractor

Item Description Catalog Number


White Polyester Reflectors Furnished with stainless steel screws
Standard Dome CMR4-ST ➊
For use with globe fixtures 30° Angle CMR4-AN
Deep Dome CMR4-DD ➊➋

Standard and Deep Dome 30° Angle

Guards
Globe Guard KPGU400
Refractor Guard KPBG12
Enclosed Reflector Guard GHB7000-NG

Globe Guard Refractor Guard

Enclosed Reflector Guard


➊ Contact your local sales representative if used with KPWB or KPST mounting hoods.
➋ Complies Dark Skies.
➌ Not suitable for use with Z, Z2 or ZB suffixes (Zone 2).

988 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class I, Zone 2, AEx nR IIC (ZB) Class II, Division 1)

Electrical Specifications Electrical Specifications


Line Type of Starting Operating Total Line Type of Starting Operating Total
Voltage Ballast ➊ Frequency Amps Amps Watts Voltage Ballast ➊ Frequency Amps Amps Watts
250 Watt High Pressure Sodium 400 Watt Metal Halide V

Lighting
120 C.W.A. 60 2.00 2.50 295 120 C.W.A. 60 3.25 4.00 458
208 C.W.A. 60 1.20 1.50 295 208 C.W.A. 60 1.90 2.30 458
240 C.W.A. 60 1.00 1.30 295 240 C.W.A. 60 1.80 2.00 458
277 C.W.A. 60 0.85 1.10 295 277 C.W.A. 60 1.70 1.75 458
347V C.W.A. 60 0.60 0.93 295 347 C.W.A. 60 1.40 1.75 458
480 C.W.A. 60 0.40 0.65 295 480 C.W.I. 60 0.85 1.00 462
120 C.W.A. 50 1.85 2.75 300 600 C.W.I. 60 0.30 0.70 475
230 C.W.A. 50 0.95 1.44 300 120 C.W.A. 50 2.70 4.10 462

Lighting: Enclosed and Gasketed — Area — HID


400 Watt High Pressure Sodium 220 C.W.A. 50 1.50 2.10 462
120 C.W.A. 60 3.30 3.80 465 240 C.W.A. 50 1.50 2.10 462
208 C.W.A. 60 1.80 2.20 465
240 C.W.A. 60 1.60 1.90 465 Fuse Kit
Order fuses as a separate item by catalog number from right columns.
277 C.W.A. 60 1.40 1.70 465
Fuse Fuse Catalog Number
347V C.W.A. 60 1.00 1.32 464
Lamp Quantity
480 C.W.A. 60 0.80 1.00 465
Watts Volts Required HPS PSMH MH V
120 C.W.A. 50 3.70 4.00 465 120 1 F7 — —
230 C.W.A. 50 1.85 2.00 465 208 2 F4 — —
250 Watt Pulse Start Metal Halide 240 2 F4 — —
120 C.W.A. 60 1.96 2.50 291 277 1 F3 — —
250 1 F3 F3 F3
208 C.W.A. 60 1.13 1.45 291 347V
480 2 F2 — —
240 C.W.A. 60 0.98 1.25 291 120 1 F7 — —
277 C.W.A. 60 0.85 1.10 291 230 2 F4 — —
347V C.W.A. 60 0.62 0.90 291 250 480 2 — F2 —
480 C.W.A. 60 0.32 0.69 298 230 1 — F3 —
120 1 — F9 —
480 Super C.W.A. 60 0.45 0.60 285 208 2 — F6 —
120 Super C.W.A. 50 1.90 2.60 288 240 2 — F5 —
230 Super C.W.A. 50 1.00 1.35 288 277 1 — F4 —
320 1 — F3 F3
320 Watt Pulse Start Metal Halide 347V
120 Super C.W.A. 60 2.60 3.25 368 480 2 — F3 —
120 1 — F10 —
208 Super C.W.A. 60 1.50 1.90 368 230 2 — F5 —
240 Super C.W.A. 60 1.30 1.65 368 120 1 — F10 —
277 Super C.W.A. 60 1.15 1.40 368 208 2 — F7 —
347V Super C.W.A. 60 0.70 1.10 368 240 2 — F5 —
277 1 — F5 —
480 Super C.W.A. 60 0.60 0.80 368 350
347V 1 — F3 —
120 Super C.W.A. 50 2.28 3.05 365 480 2 — F3 —
230 Super C.W.A. 50 1.14 1.60 365 120 1 — F10 —
350 Watt Pulse Start Metal Halide 230 2 — F5 —
120 Super C.W.A. 60 3.30 3.60 400 120 1 F15 F10 —
208 2 F8 F7 —
208 Super C.W.A. 60 1.90 2.10 400 240 2 F8 F5 —
240 Super C.W.A. 60 1.65 1.80 400 277 1 F5 F5 —
277 Super C.W.A. 60 1.40 1.55 400 400 1 F5 F5 F5
347V
347V Super C.W.A. 60 0.85 1.20 400 480 2 F5 F3 —
480 Super C.W.A. 60 0.75 0.90 400 120 1 F10 F10 —
230 2 F6 F5 —
120 Super C.W.A. 50 2.45 3.34 394
230 Super C.W.A. 50 1.26 1.74 394
400 Watt Pulse Start Metal Halide
120 Super C.W.A. 60 3.50 4.00 454
208 Super C.W.A. 60 2.00 2.30 454
240 Super C.W.A. 60 1.75 2.00 454
277 Super C.W.A. 60 1.50 1.25 454
347V Super C.W.A. 60 1.10 1.35 452
➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance
480 Super C.W.A. 60 0.90 1.00 454 High Power Factor Autotransformer.
120 Super C.W.A. 50 3.17 3.90 454 Super C.W.A. – Super Constant Wattage Autotransformer.
230 Super C.W.A. 50 1.65 2.00 454 V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 989


© September 2010
Mercmaster™ III 400 Luminaire Dimensions and Weights
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Pendant with Globe, Wall


Guard and Reflectors
Lighting
Lighting: Enclosed and Gasketed — Area — HID

25° Stanchion

Cone

Ceiling with Refractor


Enclosed Reflector and Guards

90° Stanchion

Deep Dome

Mercmaster III – 400 Ballast and Accessory Weights


Ballast Housing (Wt. Lbs/Kg) Mounting Hoods Globe Refractor, Enclosed
Lamp Watts HPS PSMH and Reflectors Wt. Lbs. Reflector and Guards Wt. Lbs/Kg
Pendant 2.25/1.0 Glass Globe 7.0/3.2
250 24.5/11.1 —
Pendant Cone 2.50/1.1 Globe Guard 3.0/1.4
Ceiling 3.00/1.4 12” Glass Refractor 12.0/5.4
320 — 28.0/12.7
Wall 4.00/1.8 Refractor Guard 4.5/2.0
25° Stanchion 3.25/1.5 Enclosed Reflector 11.0/5.0
350 — 28.5/12.9
90° Stanchion 3.75/1.7 Enclosed Reflector Guard 2.0/0.9
Standard Dome 3.50/1.6
400 28.5/12.9 28.5/12.9
30° Angle 3.50/1.6
Weights are approximate. Add 0.25 lb. for Quartz option.

990 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED

Class I, Division 2, Groups A, B, C, D


NEMA 4X

Applications Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn • Encapsulated with epoxy sealing compound
lighting control in Class I, Division 2 locations. • FS: aluminum
• Typical applications include walkways, security areas and any
other outdoor lighting application.
Certifications and Compliances

Lighting
• For use with Mercmaster III – Low Profile, Mercmaster III, and • UL Standard: 1604 ­– Hazardous (Classified) Locations
Mercmaster III – 400 Series Luminaires. • cULus Recognized
• For remote mounting in FS Boxes.
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.

Lighting: Enclosed and Gasketed — Area — HID


• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisiance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4 mm in length.
• Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1. Dimensions
Voltage Range Suffix Designation
120 V, 50/60 Hz H1
208 V, 50/60 Hz H2
240 V, 50/60 Hz H3
277 V, 50/60 Hz H4
Mercmaster III wall mounting hood
with photocontrol installed shown
1.13”
28.7 mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box


Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range Catalog Number


120V, 50/60 Hz FSKA-PC120D2
1.375”
34.9 mm
208-277V, 50/60 Hz FSKA-PC247D2 1.375”
34.9 mm

2.56”
65.0 mm
2.56”
1.13” 65.0 mm
28.7 mm

Photocontrol for Field Installation


Voltage Range Max. Current Catalog Number
120 V, 50/60 Hz 8.3 Amp PC120D2
1.375”
208-277 V, 50/60 Hz 3.5 Amp PC247D2
34.9 mm 0.69”
17.5 mm

1.19”
2.56” 30.2 mm
65.0 mm 1.94”
49.2 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 991


© September 2010
Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

* Photometric data is based on a fixture with For candlepower values of fixtures with other
a 400-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: for a 320
(44,000 lumen). W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.

Zone Lumens Total Luminaire Efficiency = 92.6%

0-10 118.85 CIE Type - General Diffuse REPORT NUMBER: KP40PG


10-20 488.36 Lamps: 400 W Pulse Start Metal Halide with Globe *
Lighting

20-30 948.99

30-40 1678.84 Coefficients of Utilization - Zonal Cavity Method

40-50 2714.15 Effective Floor Cavity Reflectance 0.20

50-60 3299.55 % Ceiling Rcc 80 70 50 30 10 0

60-70 3919.47 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 100100100100 93 93 93 93 80 80 80 68 68 68 57 57 57 51
Lighting: Enclosed and Gasketed — Area — HID

70-80 4497.45 Zonal Lumen Summary

80-90 4892.41 Zone Lumens % Lamp % Fixture 1 86 80 74 69 79 73 68 64 62 58 54 51 48 45 41 39 37 32


90-100 4803.79 0-30 1556.19 3.5 3.8 2 76 67 59 52 70 61 54 48 51 45 41 42 37 33 33 30 27 22
100-110 4404.56 0-40 3235.03 7.4 7.9 3 68 57 48 41 62 52 44 38 45 37 32 35 30 26 28 24 20 16
110-120 3849.71 0-60 9248.74 21.0 22.7 4 62 49 40 33 56 45 37 30 37 31 26 30 25 21 24 20 16 13
120-130 3078.18 0-90 22558.07 51.3 55.4 5 56 43 34 27 51 40 31 25 33 26 21 27 21 17 21 17 13 10
130-140 1852.83 90-120 13058.07 29.7 32.0 6 51 38 29 23 47 35 27 21 29 23 18 24 18 14 18 14 11 8
140-150 185.86 90-130 16136.25 36.7 39.6 7 47 34 25 20 43 31 24 18 26 20 15 21 16 12 17 12 9 7
150-160 14.88 90-150 18174.93 41.3 44.6 8 44 31 22 17 40 28 21 16 24 17 13 19 14 10 15 11 8 6
160-170 1.78 90-180 18191.71 41.3 44.6 9 41 28 20 15 37 26 18 14 21 15 11 18 13 9 14 10 7 5
170-180 0.12 0-180 40749.78 92.6 100.0 10 38 25 18 13 35 23 16 12 20 14 10 16 11 8 13 9 6 4

Zone Lumens Total Luminaire Efficiency = 81.4%

0-10 561.93 CIE Type - Direct REPORT NUMBER: KP40PST


10-20 1748.92 Lamps: 400 W Pulse Start Metal Halide with
Spacing
20-30 2859.54 Plane Criteria Standard Dome Reflector *
30-40 4018.21 0-180 1.76 Coefficients of Utilization - Zonal Cavity Method

40-50 5254.58 90-270 1.76 Effective Floor Cavity Reflectance 0.20

50-60 5772.38 Diagonal 1.86 % Ceiling Rcc 80 70 50 30 10 0

60-70 6052.84 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 5887.04 Zonal Lumen Summary 0 97 97 97 97 95 95 95 95 90 90 90 86 86 86 83 83 83 81

80-90 3512.71 Zone Lumens % Lamp % Fixture 1 84 78 73 68 81 76 71 67 72 69 65 69 66 63 66 63 61 59


90-100 137.17 0-30 5170.39 11.8 14.4 2 74 65 58 51 72 63 57 51 60 54 49 57 52 48 55 51 47 45
100-110 0.00 0-40 9188.60 20.9 25.7 3 66 55 47 40 64 54 46 40 51 44 39 49 43 38 46 42 37 35
110-120 0.00 0-60 20215.55 45.9 56.5 4 60 48 39 32 58 47 39 32 44 37 32 42 36 31 40 35 31 28
120-130 0.00 0-90 35668.14 81.1 99.6 5 55 42 33 27 53 41 33 27 39 32 26 37 31 26 36 30 26 24
130-140 0.00 90-120 137.17 0.3 0.4 6 50 37 29 23 48 36 28 23 35 28 22 33 27 22 32 26 22 20
140-150 0.00 90-130 137.17 0.3 0.4 7 46 33 25 20 44 33 25 19 31 24 19 30 24 19 29 23 19 17
150-160 0.00 90-150 137.17 0.3 0.4 8 43 30 22 17 41 30 22 17 28 22 17 27 21 17 26 21 17 15
160-170 0.00 90-180 137.17 0.3 0.4 9 40 28 20 15 38 27 20 15 26 19 15 25 19 15 24 19 15 13
170-180 0.00 0-180 35805.32 81.4 100.0 10 37 25 18 13 36 25 18 13 24 18 13 23 17 13 22 17 13 12

992 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

* Photometric data is based on a fixture with For candlepower values of fixtures with other
a 400-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: for a 320
(44,000 lumen). W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.

Zone Lumens Total Luminaire Efficiency = 76%

0-10 499.96 CIE Type - Direct REPORT NUMBER: KP40PAN


10-20 1605.38
Spacing
Lamps: 400 W Pulse Start Metal Halide with
30° Angle Dome Reflector *

Lighting
20-30 2680.72 Plane Criteria

30-40 3841.49 0-180 2.28 Coefficients of Utilization - Zonal Cavity Method

40-50 4899.23 90-270 1.92 Effective Floor Cavity Reflectance 0.20

50-60 4819.21 Diagonal 1.84 % Ceiling Rcc 80 70 50 30 10 0

60-70 4564.58 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Lighting: Enclosed and Gasketed — Area — HID


70-80 4063.65 0 89 89 89 89 86 86 86 86 80 80 80 75 75 75 71 71 71 69

80-90 3258.13 1 78 72 68 64 75 70 66 62 65 62 59 61 58 56 57 55 53 50

90-100 2105.14 Zonal Lumen Summary 2 69 61 55 49 66 59 53 48 55 50 46 51 47 43 48 44 41 39

100-110 762.24 Zone Lumens % Lamp % Fixture 3 62 52 45 39 59 51 44 38 47 41 37 44 39 35 41 37 33 31

110-120 138.12 0-30 4786.06 10.9 14.3 4 56 46 38 32 54 44 37 31 41 35 30 38 33 29 36 31 28 26

120-130 77.59 0-40 8627.55 19.6 25.8 5 51 40 33 27 49 39 32 26 36 30 25 34 29 24 32 27 23 21

130-140 73.07 0-60 18345.99 41.7 54.9 6 47 36 28 23 45 35 28 22 32 26 22 30 25 21 29 24 20 18

140-150 25.07 0-90 30232.35 68.7 90.4 7 43 32 25 20 42 31 24 19 29 23 19 27 22 18 26 21 17 16

150-160 10.91 90-120 3005.49 6.8 9.0 8 40 29 22 17 39 28 22 17 27 21 16 25 20 16 24 19 15 14

160-170 5.30 90-130 3083.09 7.0 9.2 9 37 26 20 15 36 26 19 15 24 19 15 23 18 14 22 17 14 12

170-180 1.45 90-150 3181.23 7.2 9.5 10 35 24 18 14 34 24 17 13 22 17 13 21 16 13 20 15 12 11


90-180 3198.89 7.3 9.6
0-180 33431.25 76.0 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 993


© September 2010
Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

* Photometric data is based on a fixture with For candlepower values of fixtures with other
a 400-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers: for a 320
(44,000 lumen). W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.

Zone Lumens Total Luminaire Efficiency = 78.4%

0-10 77.24 CIE Type - Semi-Direct REPORT NUMBER: KP40PJ5


10-20 575.14 Lamps: 400 W Pulse Start Metal Halide with
Spacing
8” Prismatic Glass Refracter - NEMA Type V *
Lighting

20-30 1061.45 Plane Criteria

30-40 1581.40 0-180 1.36 Coefficients of Utilization - Zonal Cavity Method

40-50 4468.52 90-270 1.40 Effective Floor Cavity Reflectance 0.20

50-60 4938.88 Diagonal 2.42 % Floors Rfc 20

60-70 6338.26 % Ceiling Rcc 80 70 50 30 10 0


Lighting: Enclosed and Gasketed — Area — HID

70-80 5875.90 Zonal Lumen Summary % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

80-90 3886.90 Zone Lumens % Lamp % Fixture 0 90 90 90 90 87 87 87 87 80 80 80 74 74 74 68 68 68 65


90-100 1318.17 0-30 1713.83 3.9 5.0 1 77 71 66 61 73 68 63 59 62 58 54 57 53 50 52 49 47 44
100-110 1872.98 0-40 3295.23 7.5 9.6 2 67 58 50 44 64 55 48 42 50 44 39 45 41 37 41 37 34 31
110-120 1122.17 0-60 12702.64 28.9 36.8 3 59 48 40 33 56 46 38 32 42 35 30 38 32 27 34 29 25 23
120-130 616.83 0-90 28803.69 65.5 83.5 4 53 41 33 26 50 39 31 25 35 29 23 32 26 21 29 24 20 17
130-140 358.56 90-120 4313.33 9.8 12.5 5 48 36 27 21 45 34 26 20 31 24 18 28 22 17 25 20 16 13
140-150 224.03 90-130 4930.15 11.2 14.3 6 44 31 23 17 41 30 22 16 27 20 15 24 18 14 22 17 13 11
150-160 128.38 90-150 5512.75 12.5 16.0 7 40 28 20 14 38 26 19 14 24 17 13 22 16 12 19 14 11 9
160-170 50.79 90-180 5699.61 13.0 16.5 8 37 25 17 12 35 24 17 11 22 15 11 19 14 10 18 13 9 7
170-180 7.69 0-180 34503.3 78.4 100.0 9 34 22 15 10 32 21 15 10 20 13 9 18 12 8 16 11 8 6
10 32 20 14 9 30 20 13 9 18 12 8 16 11 7 15 10 7 5

Zone Lumens Total Luminaire Efficiency = 64.2%

0-10 514.26 CIE Type - Direct REPORT NUMBER: KP40PHB


10-20 1734.49 Lamps: 400 W Pulse Start Metal Halide with
Spacing
20-30 3370.99 Plane Criteria Enclosed Reflector (KPR-4HB) *
30-40 5333.06 0-180 2.32 Coefficients of Utilization - Zonal Cavity Method

40-50 7165.13 90-270 2.32 Effective Floor Cavity Reflectance 0.20

50-60 6195.93 Diagonal 2.04 % Floors Rfc 20

60-70 2879.28 % Ceiling Rcc 80 70 50 30 10 0

70-80 921.95 Zonal Lumen Summary % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

80-90 111.28 Zone Lumens % Lamp % Fixture 0 76 76 76 76 75 75 75 75 71 71 71 68 68 68 65 65 65 64


90-100 0.14 0-30 5619.74 12.8 19.9 1 70 67 65 63 69 66 64 62 63 61 60 61 59 58 59 57 56 55
100-110 0.00 0-40 10952.81 24.9 38.8 2 64 59 55 51 62 58 54 50 55 52 49 53 51 48 51 49 47 46
110-120 0.00 0-60 24313.86 55.3 86.1 3 58 51 46 42 56 50 46 42 48 44 41 47 43 40 45 42 40 38
120-130 0.00 0-90 28226.37 64.2 100.0 4 53 45 39 35 51 44 39 35 43 38 34 41 37 34 40 36 33 32
130-140 0.00 90-120 0.14 0.0 0.0 5 48 40 34 30 47 39 34 29 38 33 29 36 32 29 35 31 28 27
140-150 0.00 90-130 0.14 0.0 0.0 6 44 35 29 25 43 35 29 25 34 29 25 32 28 25 31 28 24 23
150-160 0.00 90-150 0.14 0.0 0.0 7 41 32 26 22 39 31 26 22 30 25 22 29 25 21 28 24 21 20
160-170 0.00 90-180 0.14 0.0 0.0 8 37 29 23 19 36 28 23 19 27 22 19 26 22 19 26 22 19 17
170-180 0.00 0-180 28226.50 64.2 100.0 9 35 26 20 17 34 25 20 17 25 20 17 24 20 16 23 19 16 15
10 32 24 18 15 32 23 18 15 23 18 15 22 18 15 21 17 15 13

994 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— Areas where flammable gases, vapors or combustible dusts
are present under conditions defined by the IEC as Zone 2

Lighting
and 22
— Applications where energy efficient, high lumen output is
required
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills

Lighting: Enclosed and Gasketed — Area — HID


— Processing plants
— Chemical plants
— Oil refineries Low Profile Ceiling Mount with 50-200 Watt 25° Stanchion Mount
— Foundries Prismatic Globe and Optional Guard with Prismatic Globe
— Manufacturing plants
— Storage areas
— Waste and sew­age treat­ment
— Oth­er ar­e­as where dust, wa­ter, dirt and rough us­age are a
prob­lem
Features
• Power supply 230/240 V (+6% - 10%) 50 Hz.
• Instant relighting with auxiliary halogen lamps, depending on
model (lamps not supplied).
• Fast relighting for 70 W and 150 W sodium: 5 to 30 seconds
depending on the duration of the mains power supply failure.
• Connection via terminal block (0.003 x 0.006 in2 /
2 x 4 mm2 max.).
• Superior corrosion-resistance: copperfree die-cast mounting
hoods, ballast housing and guards have a gray epoxy powder
coat, electrostatically applied for complete and uniform
protection.
• Wide choice of light sources: high pressure sodium, metal
halide, mercury vapor and incandescent. 50-200 Watt 90° Stanchion Mount 400 Watt Straight Stanchion Mount
• Six mounting arrangements to suit any lighting layout – pendant, with Prismatic Globe and with Prismatic Glass Globe and
ceiling, wall bracket, angled or straight stanchion and pendant Optional Guard Optional Guard
cone (for dust applications).
• Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360°
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies Standard Materials
servicing. • Mounting hoods and ballast bodies: die-cast copperfree (4/10
• All fixtures designed to perform in a -40 °F/-40 °C ambient of 1% max.) aluminum
temperature up to 131 °F/55 °C. • Hardware and catch assemblies: stainless steel
• Standard dome or 30° angle reflectors made of fiberglass • Globe: heat and impact resistant internally fluted glass
reinforced white polyester. Highly resistant to corrosive • Gasket: high temperature silicon
atmospheres and vented to improve fixture cooling • Reflector: fiberglass reinforced polyester
characteristics. • Guards: polyester powder coat finished cast copperfree
• Fixture housing mounting hoods and guards are die-cast aluminum (LN1 and LN2 sizes) or stainless steel (LN3 and LN4
copperfree aluminum with epoxy powder coat finish. sizes)
• All exposed hardware is stainless steel and captive. Stainless
thread inserts in the ballast bodies prevent “freezing” of the
Standard Finishes
screws that affix guards and reflectors, simplifying removal for • Mounting hoods, ballast bodies and guards: epoxy powder coat
service. finish, electrostatically applied for complete, uniform surface
• One-piece ballast housing for each component provides even protection
heat dissipation for cooler operation and longer ballast life. • Reflectors: white polyester finish
• Fixture bodies are provided with two silicone rubber O-Ring
style gaskets that will stay flexible and assure even compression
around their circumference. They easily withstand high
temperatures, moisture, dirt and dust for worry free operation.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 995


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Certifications and Compliances


• Gas: Certification Type LN
— Zone 2
— Conforming to ATEX 94/9/CE: CE II3 G
— ATEX/IEC Protection: Ex nR II
Lighting

— Ambient Temperature: 104 °F/40 °C to 131 °F/55 °C


— CE Declaration of Conformity: 50217
— ATEX Certificate: LCIE 08 ATEX 6036X
— IEC Certificate: LCIE Ex 08.003X
— Other Certifications: GOST
• Dust: Certification Type LN
— Zone 22
— Conforming to ATEX 94/9/CE: CE II3 D
Lighting: Enclosed and Gasketed — Area — HID

— ATEX/IEC Protection: Ex tD A22


— Ambient Temperature: 104 °F/40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50217
— ATEX Certificate: LCIE 08 ATEX 6036X
— IEC Certificate: LCIE Ex 08.003X
— Other Certifications: GOST
• Ex standards :EN / IEC 60079-0; 60079-15; 61241-0; 61241-1
• Product standards: EN / IEC 60598-1
• EMC standards: EN / IEC 55015; 61547
• Other standards: EN / IEC 60529 (IP)

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide for LN Series Luminaires
LN 1 A H 70 A G2 XA P

Series: Mounting: Lamp Wattage: Globe: Options:


LN - LN Series A - Pendant 70 - 70 W G2 - Glass Globe P - PTFE Coating
Zone 2, 22 (Rigid 80 - 80 W VPGL-2HR
ATEX/IEC Certified Mounting) 85 - 85 W G4 - Glass Globe
C - Ceiling Induction only VPGL-4HR
D - Pendant Cone 10 - 100 W
F - Pendant 12 - 125 W
(Flexible 15 - 150 W
Mounting) 25 - 250 W
R - Straight 40 - 400 W
Stanchion
S - 25° Stanchion
W - Wall

Body Size: Lamp Type: Hub Size: Voltage (Magnetic Ballast):


1 - Size 1 (MLBG) H - Metal Halide A - M20 XA - 220 Vac 50 Hz
2 - Size 2 (KPB) L - Sodium 2 - 3/4" NPT XJ - 230/240 Vac 50 Hz
3 - Size 3 (KPBR) M - Mercury Vapor 3 - 1" NPT
4 - Size 4 (KPB400) Q - Induction 4 - 1-1/4" NPT
Z - Halogen/ 5 - 1-1/2" NPT
Incandescent

996 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Zone 2 and 22
II 3 GD
ATEX / IEC IP66

T Rating for Zone 2 Locations


Not available for Zone 22 locations

Zone 22 Surface Temperature for


Zone 2 T Rating Ambient Temperatures
Ambient T° = +131 °F/+55°C

Lighting
+104 °F/+40°C +122 °F/+50°C +131 °F/+55°C Dust Surface Cable
70 W HPS T Rating T4 T4 T4 235 °F/113 °C —
100 W HPS T Rating T4 T3 T3 289 °F/143 °C —
100 W Incandescent T Rating T4 T3 T3 289 °F/143 °C —
100 W Halogen T Rating T4 T3 T3 289 °F/143 °C —

Lighting: Enclosed and Gasketed — Area — HID


125 W Mercury T Rating T4 T3 T3 289 °F/143 °C —
150 W HPS T Rating T4 T3 T3 289 °F/143 °C —
150 W Halide T Rating T4 T3 T3 289 °F/143 °C —
150 W Incandescent T Rating T4 T3 T3 289 °F/143 °C —
150 W Halogen T Rating T4 T3 T3 289 °F/143 °C —
250 W HPS T Rating T4 T4 T3 279 °F/137 °C —
250 W Halide T Rating T4 T3 T3 289 °F/143 °C —
250 W Mercury T Rating T4 T3 T3 289 °F/143 °C —
T Rating T3 T3 T3
400 W HPS 333 °F/167 °C 192 °F/89 °C
Cable T° – 183 °F/84 °C 192 °F/89 °C
T Rating T3 T3 T3
400 W Halide 340 °F/171 °C 189 °F/87 °C
Cable T° – 180 °F/82 °C 189 °F/87 °C
T Rating T3 T3 T3
400 W Mercury 340 °F/171 °C 192 °F/89 °C
Cable T° – 183 °F/84 °C 192 °F/89 °C

“T” Numbers Represent the Maximum Lamp Temperature Locations and Maximum Surface Temperature Under Dust Blanket.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)

Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 997


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp Lamp Weight Volume Catalog


Type Cable Entry Watts Lampholder Lbs/kg (in3/dm3) Number
Pendant
70 E27 16.31/7.4 2379.93/39 LN1AL702G2XJ
Lighting

100 E40 19.84/9.0 3356.31/55 LN2AL102G2XJ


HPS 1 x 3/4” NPT 150 E40 19.84/9.0 3356.31/55 LN2AL152G2XJ
250 E40 35.27/16.0 4271.66/70 LN3AL252G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4AL402G4XJ
Lighting: Enclosed and Gasketed — Area — HID

Pendant Cone
70 E27 16.31/7.4 2379.93/39 LN1DL702G2XJ
100 E40 19.84/9.0 3356.31/55 LN2DL102G2XJ
HPS 1 x 3/4” NPT 150 E40 19.84/9.0 3356.31/55 LN2DL152G2XJ
250 E40 35.27/16.0 4271.66/70 LN3DL252G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4DL402G4XJ

Ceiling
70 E27 16.31/7.4 2379.93/39 LN1CL70AG2XJ
5 x 1” NPT with: 100 E40 19.84/9.0 3356.31/55 LN2CL10AG2XJ
- 4 x 1” NPT fitted plugs
HPS 150 E40 19.84/9.0 3356.31/55 LN2CL15AG2XJ
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs 250 E40 35.27/16.0 4271.66/70 LN3CL25AG4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4CL40AG4XJ

Wall
70 E27 16.31/7.4 2379.93/39 LN1WL70AG2XJ
5 x 1” NPT with: 100 E40 19.84/9.0 3356.31/55 LN2WL10AG2XJ
- 4 x 1” NPT fitted plugs
HPS 150 E40 19.84/9.0 3356.31/55 LN2WL15AG2XJ
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs 250 E40 35.27/16.0 4271.66/70 LN3WL25AG4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4WL40AG4XJ

25° Angled Stanchion


70 E27 16.31/7.4 2379.93/39 LN1SL704G2XJ
100 E40 19.84/9.0 3356.31/55 LN2SL104G2XJ
HPS 1 x1- 1/4” NPT 150 E40 19.84/9.0 3356.31/55 LN2SL154G2XJ
250 E40 35.27/16.0 4271.66/70 LN3SL254G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4SL404G4XJ

Straight Stanchion
70 E27 16.31/7.4 2379.93/39 LN1RL704G2XJ
100 E40 19.84/9.0 3356.31/55 LN2RL104G2XJ
HPS 1 x1- 1/4” NPT 150 E40 19.84/9.0 3356.31/55 LN2RL154G2XJ
250 E40 35.27/16.0 4271.66/70 LN3RL254G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4RL404G4XJ

998 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp Weight Volume Catalog


Lamp Type Cable Entry Watts Lampholder Lbs/kg (in3/dm3) Number
Pendant
Inc./ 100 E27 16.31/7.4 2379.93/39 LN1AZ102G2

Lighting
1 x 3/4” NPT
Halogen 150 E27 16.31/7.4 2379.93/39 LN1AZ152G2

Lighting: Enclosed and Gasketed — Area — HID


Pendant Cone
Inc./ 100 E27 16.31/7.4 2379.93/39 LN1DZ102G2
1 x 3/4” NPT
Halogen 150 E27 16.31/7.4 2379.93/39 LN1DZ152G2

Ceiling
5 x 1” NPT with: 100 E27 16.31/7.4 2379.93/39 LN1CZ10AG2
Inc./ - 4 x 1” NPT fitted plugs
Halogen - 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs 150 E27 16.31/7.4 2379.93/39 LN1CZ15AG2

Wall

Inc./ 5 x 1” NPT with: 100 E27 16.31/7.4 2379.93/39 LN1WZ10AG2


Halogen - 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors 150 E27 16.31/7.4 2379.93/39 LN1WZ15AG2
- 2 x M20 plugs

25° Angled Stanchion


Inc./ 100 E27 16.31/7.4 2379.93/39 LN1SZ104G2
1 x1- 1/4” NPT
Halogen 150 E27 16.31/7.4 2379.93/39 LN1SZ154G2

Straight Stanchion
Inc./ 100 E27 16.31/7.4 2379.93/39 LN1RZ104G2
1 x1- 1/4” NPT
Halogen 150 E27 16.31/7.4 2379.93/39 LN1RZ154G2

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 999


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp Weight Volume Catalog


Lamp Type Cable Entry Watts Lampholder Lbs/kg (in3/dm3) Number
Pendant
150 E27 16.31/7.4 2379.93/39 LN1AM122G2XJ
Lighting

MV 1 x 3/4” NPT 250 E40 30.86/14.0 4271.66/70 LN3AM252G4XJ


400 E40 41.89/19.0 5199.22/85.2 LN4AM402G4XJ
Lighting: Enclosed and Gasketed — Area — HID

Pendant Cone
150 E27 16.31/7.4 2379.93/39 LN1DM122G2XJ
MV 1 x 3/4” NPT 250 E40 30.86/14.0 4271.66/70 LN3DM252G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4DM402G4XJ

Ceiling
5 x 1” NPT with: 150 E27 16.31/7.4 2379.93/39 LN1CM12AG2XJ
- 4 x 1” NPT fitted plugs
MV 250 E40 30.86/14.0 4271.66/70 LN3CM25AG4XJ
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs 400 E40 41.89/19.0 5199.22/85.2 LN4CM40AG4XJ

Wall
5 x 1” NPT with: 150 E27 16.31/7.4 2379.93/39 LN1WM12AG2XJ
- 4 x 1” NPT fitted plugs
MV 250 E40 30.86/14.0 4271.66/70 LN3WM25AG4XJ
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs 400 E40 41.89/19.0 5199.22/85.2 LN4WM40AG4XJ

25° Angled Stanchion


150 E27 16.31/7.4 2379.93/39 LN1SM124G2XJ
MV 1 x 1-1/4” NPT 250 E40 30.86/14.0 4271.66/70 LN3SM254G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4SM404G4XJ

Straight Stanchion
150 E27 16.31/7.4 2379.93/39 LN1RM124G2XJ
MV 1 x 1-1/4” NPT 250 E40 30.86/14.0 4271.66/70 LN3RM254G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4RM404G4XJ

1000 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp Lamp Weight Volume Catalog


Type Cable Entry Watts Lampholder Lbs/kg (in3/dm3) Number
Pendant
150 E40 19.84/9.0 3356.31/55 LN2AH152G2XJ

Lighting
MH 1 x 3/4” NPT 250 E40 35.27/16.0 4271.66/70 LN3AH252G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4AH402G4XJ

Lighting: Enclosed and Gasketed — Area — HID


Pendant Cone
150 E40 19.84/9.0 3356.31/55 LN2DH152G2XJ
MH 1 x 3/4” NPT 250 E40 35.27/16.0 4271.66/70 LN3DH252G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4DH402G4XJ

Ceiling
5 x 1” NPT with: 150 E40 19.84/9.0 3356.31/55 LN2CH15AG2XJ
- 4 x 1” NPT fitted plugs
MH 250 E40 35.27/16.0 4271.66/70 LN3CH25AG4XJ
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs 400 E40 41.89/19.0 5199.22/85.2 LN4CH40AG4XJ

Wall
5 x 1” NPT with: 150 E40 19.84/9.0 3356.31/55 LN2WH15AG2XJ
- 4 x 1” NPT fitted plugs
MH 250 E40 35.27/16.0 4271.66/70 LN3WH25AG4XJ
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs 400 E40 41.89/19.0 5199.22/85.2 LN4WH40AG4XJ

25° Angled Stanchion


150 E40 19.84/9.0 3356.31/55 LN2SH154G2XJ
MH 1 x 1-1/4” NPT 250 E40 35.27/16.0 4271.66/70 LN3SH254G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4SH404G4XJ

Straight Stanchion
150 E40 19.84/9.0 3356.31/55 LN2RH154G2XJ
MH 1 x 1-1/4” NPT 250 E40 35.27/16.0 4271.66/70 LN3RH254G4XJ
400 E40 41.89/19.0 5199.22/85.2 LN4RH404G4XJ

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1001


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Item Description Catalog Number


White Polyester Reflectors — Furnished with stainless steel screws
For Globe Fixtures – LN1 and LN2 sizes
Lighting

Standard Dome KR2-ST


30° Angle KR2-AN
For Glass Refractor Fixtures † – LN3 and LN4 sizes
Standard Dome CMR-4ST
Standard Dome 30° Angle 30° Angle CMR-4AN
Lighting: Enclosed and Gasketed — Area — HID

Guards
For Globe Fixtures – LN1 and LN2 sizes
Aluminum KRGU2
For Glass Refractor Fixtures †
– LN3 and LN4 sizes
Stainless Steel KPGU400

Globe Guard Globe Guard

† Fixtures with refractors are not UL Listed when used with reflectors.

1002 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22

Ballast Body with Globe

LN1 LN2 LN3 LN4

Lighting
13.52”/346.0 mm 13.52”/346.0 mm 13.52”/346.0 mm
13.52”/346.0 mm
Fix. Fix. Fix. Fix.
12.68”/322.0 mm 12.68”/322.0 mm 12.68”/322.0 mm 12.68”/322.0 mm
11.61”/295.0 mm

10.83”/275.0 mm

Lighting: Enclosed and Gasketed — Area — HID


16.73”/425.0 mm

20.50”/520.7 mm
Mounting Hoods

Pendant Pendant Cone Ceiling


1.17”/ 12.06”/306.0 mm 13.62”/346.0 mm 1.75”/
30.0 mm 45.0 mm
12.06”/306.0 mm 12.06”/306.0 mm 5.00”/
127.0 mm 2.00”/
5.59”/ 50.8 mm
Dia. (+DFT)
142.0 mm
0.375”/ 0.56”/
9.5 mm 14.3 mm
Dia. (+DFT) Dia. (+DFT)

2.50”/
63.5 mm
Dia. (+DFT)

Wall 25° Stanchion 90° Stanchion


17.01”/ 3.38”/ 17.23”/438.0 mm
432.0 mm 85.8 mm
(4) Mounting Holes 15.28”/ 2.00”/
10.94”/ 0.31”/8.0 mm 388.0 mm 51.0 mm 9.79”/249.0 mm
278.0 mm
4.06”/ 9.25”/
103.0 mm 235.0 mm

12.05”/
12.05”/ 306.0 mm
306.0 mm
12.06”/306.0 mm
7.60”/
193.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1003


© September 2010
LN Series Wellglass Luminaire Photometric Data
Zone 2 and 22

Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal


Luminaire symbol according to NF C 71-121
Transverse
High Pressure Sodium
70 W HP Sodium 150 W HP Sodium 250 W HP Sodium 400 W HP Sodium
Lighting

Efficiency 74.6% Efficiency 87.3% Efficiency 89.1% Efficiency 82.3%


Degrees Degrees Degrees Degrees
Lighting: Enclosed and Gasketed — Area — HID

Metal Halide
150 W Metal Halide 250 W Metal Halide 400 W Metal Halide
Efficiency 82.4% Efficiency 96.2% Efficiency 89.8%
Degrees Degrees Degrees

Incandescent or Halogen
150 W HP Incandescent Halogen
Efficiency 90.6%
Degrees

Mercury Vapor
250 W Mercury Vapor
Efficiency 76%
Degrees

1004 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaires
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Applications
• Enclosed and gasketed HID lighting fixtures for use in tunnels,
walkways, bridges, storage facilities, processing plants, parking
lots, foundries, manufacturing plants, power plants and other
locations where moisture, dirt, dust or corrosive atmospheres

Lighting
are encountered.
• Fixtures suited for Class I, Division 2; Class II, Division 1 and
2; and Class III. Suitable for use in wet and outdoor saltwater
locations.
• Wide range of wattages and voltages. Choice of ballasts for 100
W-200 W PSMH; and 50 W-150 W HPS lamps in 120, 208, 240,
277 and 480 voltages.
• Choice of light sources: high pressure sodium and pulse start

Lighting: Enclosed and Gasketed — Area — HID


metal halide.
• Choice of optical assembles: (1) prismatic globe with or without
guard through 200 W; or (2) Type V closed prismatic glass
refractor through 200 W. (Types II, III and IV also available Standard Materials
through 200 W. Also polycarbonate globes for 100 W max.) • Mounting hoods, ballast bodies and guards: copperfree (4/10 of
• Choice of mounting hoods: pendant (rigid or flexible), 25° (angle) 1% max.) aluminum
stanchion, ceiling and wall mounting. • Reflectors: fiberglass reinforced polyester
• Porcelain reflector for standard applications and Fiberglass • Globes: 50 W-100 W, threaded prismatic glass; 150 W, 175 W
reinforced polyester reflector for installations where luminaire is and 200W, threaded heat-resistant prismatic glass
subject to exceptionally severe corrosive atmospheres. • Refractors: 50 W to 150 W, heat-resistant prismatic glass and
plastic; 175 W to 200 W, prismatic glass
Features
• Superior corrosion-resistance: copperfree aluminum mounting Standard Finishes
hoods, ballasts and guards with epoxy powder coat, inside • Mounting hoods, ballast bodies, guards: epoxy powder-coat
and out. finish. Two-coat baked finish, electrostatically applied for
• Standard pendant mounting hood for rigid or flexible mounting. complete uniform surface protection
Balanced round design automatically hangs plumb when used • Polyester reflectors: natural finish
with flexible hanger.
• Positive sealing. Hinge and bolt construction assures 360°
Options
compression at all points on gasket. • Fuses for fixtures. For fuse kits see Electrical Specifications and
• One-piece ballast housing for each component provides even Fuse Kits page.
heat dissipation for cooler operation and longer ballast life. • MH fixtures for Quartz Auxiliary lamps. Relay switch installed
• Heat barrier isolates capacitor from ballast. Standard non-PCB in fixture when specified. Add suffix -MTE to fixture catalog
biodegradable capacitors installed in separate compartment. number for 120 V through 277 V, and suffix -480E to fixture
• Mogul socket is furnished with 392 °F/200 °C welded leads, catalog number for 480 V fixture.
pre-wired to the ballast. • Smart Hot Restrike emergency option, available for 50 W-150 W
• Porcelain socket assures trouble-free operation in high ambient HPS only. Add suffix -SR. See 50 W, 70 W, 100W, 150 W HPS
installations. page.
• Guards protect globes from damage. Keyhole slots allow easy • Hot Restrike option add suffix -R.
installation and are secured with stainless steel screws. • Smart Starter available for HPS and PSMH. Add suffix -S.
• Prismatic glass globes and glass Certifications and Compliances
refractors are standard (plastic refractors also available) and
thread directly into fixture housing. Eliminate glare and provide • UL Standard: UL 1598, UL 1598A, UL 844
uniform light distribution. • UL Listed: E10444
• Vented reflectors result in cooler, dirt-free operation, increased
lumen output.
• Reflectors secured to mounting hood with screws (furnished).
• Choice of reflector styles: white porcelain enamel or Fiberglass
reinforced polyester; standard dome or 30° angle.
• Optional photocell provides automatic “on-off” control.
• All Mercmaster mounting hoods have provision for easy field
installation of fuses in fixtures (see fuse kit listings).

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
Note: Fixtures equipped with optional photocell or quartz auxilliary lamp do not comply with UL requirements and are not suitable for use in classfied locations.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1005


© September 2010
Mercmaster™ II HID Luminaires
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Illustrated Features
Lighting
Lighting: Enclosed and Gasketed — Area — HID

High Temperature Sockets


Mogul base high temperature socket for
50W through 400W HID lamps.

Aluminum Inner Reflector Hood/Ballast Gasket


Solid aluminum inner reflector improves Silicone rubber gasket seals out moisture,
photometric efficiency. dirt and dust.

Epoxy Finish
Ballast housing, hoods and guards are JB Series Box and
Stainless Steel copperfree aluminum with epoxy powder
Latch Assembly Flexible Hanger
coat finish.
Captive, stainless
steel latch assembly Electrical Protection
bolt and nut closes Ground wire provided to bond mounting
securely, resists hood to ballast housing. Fiber insulator Balanced Round
attack of corrosive protects ballast and capacitor. Design
atmospheres. Pendant fixtures
Swing-away design automatically hang
simplifies servicing. plumb. Fixtures and
hangers suitable for
Class I, Division 2
applications.
Photocell
Installs through knock-out in mounting
"Safety" High hood; provides continuous ON-OFF dusk-
Hinge to-dawn control. Fixtures with optional
Extra-high hinge photocell or quartz auxiliary lamp do not
provides additional comply with UL requirements for use in
protection against classified locations.
accidental
ballast housing
disengagement
during installation
or maintenance.

Fuses Mount to Hood Bosses


Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.

1006 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaires
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Quartz Emergency Light for Pulse Start Metal Halide or High Pressure Sodium Fixtures *
Mercmaster fixtures for or metal halide and high pressure sodium lamps can be supplied with
a socket to accept a 150 W 120 V quartz lamp. This D.C. bayonet base socket is in addition to
the standard lamp socket. In the event of a momentary power interruption, the quartz lamp is
automatically switched on. The single ended quartz lamp remains energized until the HID restrikes

Lighting
and reaches about 60% output.

The quartz emergency lamp socket is wired to a 120 V tap on the ballast and is therefore
independent of the lighting fixture voltage. No special field wiring is necessary.
Description Catalog Suffix
For fixture volts of 120, 208, 240 or 277 -MTE
For fixture volts of 480 -480E

Lighting: Enclosed and Gasketed — Area — HID


HPS Smart Hot Restrike Accessory for HPS Fixtures
Mercmaster fixtures for high pressure sodium lamps can be supplied with a special ignitor (starter
board). It instantly restrikes a hot high pressure sodium lamp when a momentary power interruption
occurs. This special ignitor, supplied in place of the standard ignitor, is a potted solid state device,
totally factory installed. It is not suitable for field installation.

The hot lamp restart option provides instant restart of 50, 70, 100 and 150 W HPS lamps after
power outages of up to 10 seconds. The lamps restrike instantly at almost full lumens. For power
interruptions of up to 30 seconds, the restart of the high pressure sodium lamp is also instant but
at less than full lumens. The hot lamp restart accessory does not accelerate cold lamp start up or
starting where the power outage is of a duration which has allowed the HPS lamp to cool.

Additional Advantages of the Smart Hot Restrike:


• Protects against self destruction in the event of failed, missing or broken lamps, or socket or
lead wire failure.
• Prevents “End of Life” lamps from continuous cycling over long periods of time.
• Remains unaffected by stray voltages, moderate overvoltages, as well as undervoltage
conditions.
Encapsulated HPS • Drops into the background during normal lamp operation with exceptionally low insertion loss.
Smart Hot Restrike • Fully encapsulated construction assures electrical integrity and mechanical vibration protection.
Ignition Accessory • UL recognized component.

Description Catalog Suffix


For fixture watts of 50, 70, 100 or 150 (HPS only) -SR
Accessory Options
 Guards: Guards are die-cast copperfree aluminum with baked epoxy finish to match fixtures. Fixture
supplied with stainless steel mounting screws which thread into stainless steel inserts on fixture housing to
attach guard. To order fixture with guard, add suffix -G to catalog number before adding voltage suffix.
 Reflectors: Standard dome and 30° angle polyester reflectors.
 Hot Restrike: Instantly restrikes a hot HPS lamp when power is restored after a momentary
outage. Available factory-installed only. To order, add suffix -R to catalog number.
 Quartz Emergency Light: When ordered, HPS fixtures will be supplied with a prewired special
DC bayonet base socket to accept a 150W, 120V quartz lamp (not furnished) that automatically
switches on when a power outage occurs. Fixtures ordered with this quartz emergency lamp feature
do NOT comply with requirements for classified areas and should be used only in non-classified
locations. To order, add suffix -E to catalog number and specify if a relay switch is desired.
 Photocell and Fuses: Photocontrol.
 Smart Starter: Performs as a conventional starter in lamp start-up. Removes itself from circuit at
end of lamp life or if lamp is out of socket. Add suffix -S to catalog number.
 Smart Hot Restrike (HPS only): Will immediately restrike HPS lamp when power is restored after
a momentary power interruption. The smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates starter failures caused by prolonged
operation with cycling or failing lamps. Add suffix -SR to catalog number.

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
* NOTE: Fixtures equipped with quartz emergency light do not comply with UL requirements and are not suitable for use in classified locations.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1007


© September 2010
Mercmaster™ II HID Luminaire Thermal Suitability
Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G
UNILETS® for Use with Threaded Metal Conduit.

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

The following table shows maximum operating temperatures ignition temperature of the gas to be encountered. To illustrate, a
of Mercmaster fixtures for Class I, Division 2, in a 104 °F/ 400W HPS fixture, which has a UL-NEC Temperature Identification
40 °C ambient in free air as rated by UL. As shown, the higher the Number of 350 (619-662 °F/326-350/°C) does NOT exceed the
Temperature Identification Number, the cooler the fixture operates. Group D Methane (natural gas) ignition temperature of 1004 °F/
Keep this in mind when selecting a fixture for a specific chemical 540 °C, and is therefore suitable for use in atmospheres containing
Lighting

listed on the Classified Area Suitability pages. Per the NEC. The that chemical.
temperature marking shown on fixtures shall not exceed the

Mercmaster II Thermal Suitability


Lamp Supply Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F G
Wire Ambient
Temp. Temp. Globe & 8” 12” Globe & 8” 12”
Lighting: Enclosed and Gasketed — Area — HID

Watts Type (°F/°C) (°F/°C) Globe Reflector Refractor Refractor Globe Reflector Refractor Refractor

50 HPS 194/90 104/40 T3 T3 T3A T3A T3B T3B T3B T3B

70 HPS 194/90 104/40 T3 T3 T3A T3A T3B T3B T3B T3B

100 HPS 194/90 104/40 T2C T2C T3 T3 T3B T3B T3B T3B

150 HPS 194/90 104/40 T2A T2A T2B T2B ➊ ➊ ➊ T3B

150 PSMH 194/90 104/40 T2B T2B T2D T2D — — — —

175 PSMH 194/90 104/40 T2B T2B T2C T2C — — — —

200 PSMH 194/90 104/40 T2 T2 T2B T2B — — — —

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Number
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

All HPS fixtures suitable for operation at -40 °F/-40 °C; PSMH at -20 °F/-29 °C.
† For specific Class I suitability of each fixture listed, see Thermal Suitability above.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ Pendant, ceiling and wall mount are suitable for groups E and F only with T3A rating. Stanchion mount is suitable for groups E, F and G with a T3B rating.

1008 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaires
50 W, 70 W, 100 W, 150 W HPS
High Power Factor (Min. P.F. 90%). Suitable for Use in Wet Locations. Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

With Globe, With 8” Refractor Lamp Hub Size Catalog Numbers


Less Guard (NEMA V) Watts (Inches) With Globe ➊ With 8” Refractor ➋ With 12” Refractor
Pendant — One Hub, Rigid or Flexible Mounting
3/4 LPAL5075 ➌ LPAL5075J ➌ LPAL5075R ➌

Lighting
50
1 LPAL5010 ➌ LPAL5010J ➌ LPAL5010R ➌
3/4 LPAL7075 ➍ LPAL7075J ➍ LPAL7075R ➍
70
1 LPAL7010 ➍ LPAL7010J ➍ LPAL7010R ➍
3/4 LPAL1075 ➍ LPAL1075J ➍ LPAL1075R ➍
100
1 LPAL1010 ➍ LPAL1010J ➍ LPAL1010R ➍
3/4 LPAL1575 ➍ LPAL1575J ➍ LPAL1575R ➍

Lighting: Enclosed and Gasketed — Area — HID


150
1 LPAL1510 ➍ LPAL1510J ➍ LPAL1510R ➍
Ceiling — Five Hubs, Four Close-Up Plugs
3/4 LPCL5075 ➌ LPCL5075J ➌ LPCL5075R ➌
50
1 LPCL5010 ➌ LPCL5010J ➌ LPCL5010R ➌
3/4 LPCL7075 ➍ LPCL7075J ➍ LPCL7075R ➍
70
1 LPCL7010 ➍ LPCL7010J ➍ LPCL7010R ➍
3/4 LPCL1075 ➍ LPCL1075J ➍ LPCL1075R ➍
100
1 LPCL1010 ➍ LPCL1010J ➍ LPCL1010R ➍
3/4 LPCL1575 ➍ LPCL1575J ➍ LPCL1575R ➍
150
1 LPCL1510 ➍ LPCL1510J ➍ LPCL1510R ➍
Wall — Five Hubs, Four Close-Up Plugs
3/4 LPWBL5075 ➌ LPWBL5075J ➌ LPWBL5075R ➌
50
1 LPWBL5010 ➌ LPWBL5010J ➌ LPWBL5010R ➌
3/4 LPWBL7075 ➍ LPWBL7075J ➍ LPWBL7075R ➍
70
1 LPWBL7010 ➍ LPWBL7010J ➍ LPWBL7010R ➍
3/4 LPWBL1075 ➍ LPWBL1075J ➍ LPWBL1075R ➍
100
1 LPWBL1010 ➍ LPWBL1010J ➍ LPWBL1010R ➍
3/4 LPWBL1575 ➍ LPWBL1575J ➍ LPWBL1575R ➍
150
1 LPWBL1510 ➍ LPWBL1510J ➍ LPWBL1510R ➍
25° Stanchion — One Hub
1-1/4 LPSL50125 ➌ LPSL50125J ➌ LPSL50125R ➌
50
1-1/2 LPSL50150 ➌ LPSL50150J ➌ LPSL50150R ➌
1-1/4 LPSL70125 ➍ LPSL70125J ➍ LPSL70125R ➍
70
1-1/2 LPSL70150 ➍ LPSL70150J ➍ LPSL70150R ➍
1-1/4 LPSL10125 ➍ LPSL10125J ➍ LPSL10125R ➍
100
1-1/2 LPSL10150 ➍ LPSL10150J ➍ LPSL10150R ➍
1-1/4 LPSL15125 ➍ LPSL15125J ➍ LPSL15125R ➍
150
1-1/2 LPSL15150 ➍ LPSL15150J ➍ LPSL15150R ➍

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ To order fixture with guard, add suffix -G (before adding voltage suffix).
➋ Furnished with 8” NEMA V refractor — to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage suffix -MTMED for Medium Base, 100W (order as special).
➌ Add voltage suffix -MT for 120, 208, 240 or 277 V.
➍ Add voltage suffix -MT for 120, 208, 240 or 277 V; -480 for 480 V.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1009


© September 2010
Mercmaster™ II HID Luminaires
100 W, 150 W, 175 W, 200 W PSMH
Constant Wattage (Min. P.F. 90%). Suitable for Use in Wet Locations. Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

With Globe, With 8” Refractor Lamp Hub Size Catalog Numbers


Less Guard (NEMA V) Watts (Inches) With Globe ➊ With 8” Refractor ➋ With 12” Refractor
Pendant — One Hub, Rigid or Flexible Mounting
3/4 LPAH1075 ➍ LPAH1075J ➍ LPAH1075R ➍
Lighting

100
1 LPAH1010 ➍ LPAH1010J ➍ LPAH1010R ➍
3/4 LPAP1575 ➍ LPAP1575J ➍ LPAP1575R ➍
150
1 LPAP1510 ➍ LPAP1510J ➍ LPAP1510R ➍
3/4 LPAP1775 ➍ LPAP1775J ➍ LPAP1775R ➍
175 ‡
1 LPAP1710 ➍ LPAP1710J ➍ LPAP1710R ➍
3/4 LPAP2075 ➍ LPAP2075J ➍ LPAP2075R ➍
Lighting: Enclosed and Gasketed — Area — HID

200 ‡
1 LPAP2010 ➍ LPAP2010J ➍ LPAP2010R ➍
Ceiling — Five Hubs, Four Close-Up Plugs
3/4 LPCH1075 ➍ LPCH1075J ➍ LPCH1075R ➍
100
1 LPCH1010 ➍ LPCH1010J ➍ LPCH1010R ➍
3/4 LPCP1575 ➍ LPCP1575J ➍ LPCP1575R ➍
150
1 LPCP1510 ➍ LPCP1510J ➍ LPCP1510R ➍
3/4 LPCP1775 ➍ LPCP1775J ➍ LPCP1775R ➍
175 ‡
1 LPCP1710 ➍ LPCP1710J ➍ LPCP1710R ➍
3/4 LPCP2075 ➍ LPCP2075J ➍ LPCP2075R ➍
200 ‡
1 LPCP2010 ➍ LPCP2010J ➍ LPCP2010R ➍
Wall — Five Hubs, Four Close-Up Plugs
3/4 LPWBH1075 ➍ LPWBH1075J ➍ LPWBH1075R ➍
100
1 LPWBH1010 ➍ LPWBH1010J ➍ LPWBH1010R ➍
3/4 LPWBP1575 ➍ LPWBP1575J ➍ LPWBP1575R ➍
150
1 LPWBP1510 ➍ LPWBP1510J ➍ LPWBP1510R ➍
3/4 LPWBP1775 ➍ LPWBP1775J ➍ LPWBP1775R ➍
175 ‡
1 LPWBP1710 ➍ LPWBP1710J ➍ LPWBP1710R ➍
3/4 LPWBP2075 ➍ LPWBP2075J ➍ LPWBP2075R ➍
200 ‡
1 LPWBP2010 ➍ LPWBP2010J ➍ LPWBP2010R ➍
25° Stanchion — One Hub
1-1/4 LPSH1075 ➍ LPSH1075J ➍ LPSH1075R ➍
100
1-1/2 LPSH1010 ➍ LPSH1010J ➍ LPSH1010R ➍
1-1/4 LPSP15125 ➍ LPSP15125J ➍ LPSP15125R ➍
150
1-1/2 LPSP15150 ➍ LPSP15150J ➍ LPSP15150R ➍
1-1/4 LPSP17125 ➍ LPSP17125J ➍ LPSP17125R ➍
175 ‡
1-1/2 LPSP17150 ➍ LPSP17150J ➍ LPSP17150R ➍
1-1/4 LPSP20125 ➍ LPSP20125J ➍ LPSP20125R ➍
200 ‡
1-1/2 LPSP20150 ➍ LPSP20150J ➍ LPSP20150R ➍

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ To order fixture with guard, add suffix -G (before adding voltage suffix).
➋ Furnished with 8” NEMA V refractor — to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage suffix -MTMED for Medium Base, 100W (order as special).
➌ Add voltage suffix -MT for 120, 208, 240 or 277 V.
➍ Add voltage suffix -MT for 120, 208, 240 or 277 V; -480 for 480 V.

1010 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaires Mounting Hoods and Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
Hoods and Ballast Housings are Copperfree Aluminum (4/10 of 1%).

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Mounting Hoods
Description Hub Size (Inches) Catalog Number
Pendant

Lighting
3/4 LPA-75
One Hub, Rigid or Flexible Mounting
1 LPA-100

Ceiling

3/4 LPC-75

Lighting: Enclosed and Gasketed — Area — HID


Five Hubs, Four Close-Up Plugs
1 LPC-100

Wall

3/4 LPWB-75
Five Hubs, Four Close-Up Plugs
1 LPWB-100

25° Stanchion

1-1/4 LPS-125
One Hub
1-1/2 LPS-150

Mounting Adapter

Permits use of Mercmaster II pendant hood on existing


V-51 and Mercmaster I mounting hoods. Remove
LPAD-1
Mercmaster I ballast body from existing mounting hood,
thread in adapter and attach wire to Mercmaster II.

Mercmaster II Ballast Bodies


Ballast Body Catalog Numbers Add Voltage Suffixes ➊
Lamp Globe/12” 8”
Type Watts Refractor Refractor 120V 208V 240V 277V 480V
High Pressure Sodium
50 LPB50L LPBLH50R -MT -MT -MT -MT —
High Power 70 LPB70L LPBLH70R -MT -MT -MT -MT -480
Factor
(Min. P.F. 90%) 100 LPB100L LPBLH100R -MT -MT -MT -MT -480
150 LPB150L LPBLH150R -MT -MT -MT -MT -480
Pulse Start Metal Halide
100 LPB100H LPBH100R -MTMED -MTMED -MTMED -MTMED -480MED

Constant Wattage 150 LPB150P LPBP150R -MT -MT -MT -MT -480
(Min. P.F. 90%) 175 LPB175P LPBP175R -MT -MT -MT -MT -480
200 LPB200P LPBP200R -MT -MT -MT -MT -480

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ MT (multi-volt) ballasts can be operated at an input voltage of either 120, 208, 240 or 277 V. 480 ballasts can be operated at input voltage of 480 V.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1011


© September 2010
Mercmaster™ II HID Luminaire Accessories
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
Screws furnished to Fasten Reflectors to Ballast Body. Refractors Thread Directly into Ballast Body.

Description Catalog Number


Prismatic Glass Globes
Clear Heat-Resistant VPGL-2HR
Lighting

Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE

Coated Prismatic Tuff-Skin®  Glass Globes


Lighting: Enclosed and Gasketed — Area — HID

For use in areas where fixture is


Clear Heat-Resistant VPGL-2HRT
subject to extreme thermal shock

Polycarbonate Globes – Impact-Resistant ➊


Clear VPGL-2PL

Use 100W Lamp max.; do not use in Amber VPGL-2AMPL


ambients exceeding 77 °F/25 °C Green VPGL-2GRPL
Red VPGL-2REPL

Light IES/NECA 8” Glass 12” Glass 12” Polycarbonate


Distribution Distribution Curves (50-200 W ➊) (50-200 W ➊) (50-175 W ➋)
Closed Prismatic Refractors — 50 W-200 W ➊

NEMA I LPG-R1 — —

NEMA II — LPRF-2CG LPRF-2CP

NEMA III LPG-R3 — LPRF-3CP

8” Refractor 12” Refractor


NEMA IV — — LPRF-4CP

NEMA V LPG-R5 LPRF-5CG LPRF-5CP

➊ Polycarbonate globes are shatter-resistant – for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ideally
suited for areas where vandalism, high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 77 °F/25 °C. For burning in
vertical base-up positions only.
 Registered trademark of Thomas Manufacturing Corporation, Parkton, Md. It is recommended that guards be used with these globes.
➊ 150 W max. for HPS.
➋ 100 W max. for MH.

1012 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaire Accessories and Weights
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
Screws furnished to Fasten Reflectors to Ballast Body. Refractors Thread Directly into Ballast Body.

Description Catalog Number


Guard
Guard for Glass Globe KGU2

Lighting
Steel Guards for 8” and 12” Refractors

Lighting: Enclosed and Gasketed — Area — HID


Guard for 8” Refractor LPRG2
Guard for 12” Refractor LPBG12
3 machine screws furnished

LPRG-2 LPBG-12
Polyester Reflectors
Standard Dome KR2-ST
30° Angle KR2-AN

Standard Dome 30° Angle


Replacement Gaskets — Silicone Rubber
Globe and 12” Refractor Gasket VPGL-GK
8” Refractor Gasket KRF-GK

Photocell (Hazardous)
120 Volt PC120D2
208 thru 277 Volt PC247D2

Mounting Hood Weights


Type Weight (Lbs/Kg) Type Weight (Lbs/Kg)
Pendant 3/1.4 Wall 5/2.3
Ceiling 5/2.3 Stanchion 4/1.8

Reflectors and Refractors — Weight includes globe and guard


Catalog Catalog Catalog Catalog
Wt. Lbs/Kg Number Wt. Lbs/Kg Number Wt. Lbs/Kg Number Wt. Lbs/Kg Number
Watts HPS PSMH Standard Dome Reflector 30° Angle Reflector 8” Refractor 12” Refractor

50, 70 14 —
100 15 15 2.5/1.1 KR2-ST 2.5/1.1 KR2-AN 5.25/2.4 LPG-R1 13/5.9 LPRF-5CG

150 16 — 5.25/2.4 LPG-R3 13/5.9

175 — 16 5.25/2.4 LPG-R5 13/5.9

200 18

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1013


© September 2010
Mercmaster™ II HID Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

Class I, Division 2, Groups A, B, C, D †


Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Electrical Specifications Fuse Kit


Order fuses as a separate item by catalog number from right columns.
Line Type of Starting Operating Total
Voltage Ballast Amps Amps Watts Lamp Fuse Quantity Fuse Kit Catalog Number
50 Watt High Pressure Sodium Watts Volts Required HPS PSMH
Lighting

120 HX-HPF 0.58 0.58 64 120 1 F5 —


208 HX-HPF 0.35 0.33 64 208 2 F3 —
240 HX-HPF 0.31 0.29 64 50
240 2 F3 —
277 HX-HPF 0.25 0.25 64 277 1 F2 —
70 Watt High Pressure Sodium 120 1 F5 —
120 HX-HPF 0.90 0.82 94 208 2 F3 —
208 HX-HPF 0.50 0.48 94 70 240 2 F3 —
Lighting: Enclosed and Gasketed — Area — HID

240 HX-HPF 0.44 0.41 94 277 1 F2 —


277 HX-HPF 0.35 0.36 94 480 2 F2 —
480 HX-HPF 0.21 0.21 94 120 1 F8 F6
100 Watt High Pressure Sodium 208 2 F5 F4
120 HX-HPF 1.30 1.15 130 100 240 2 F5 F3
208 HX-HPF 0.76 0.67 130 277 1 F3 F3
240 HX-HPF 0.66 0.60 130 480 2 F3 F2
277 HX-HPF 0.60 0.52 130 120 1 F10 F10
480 HX-HPF 0.33 0.31 135 208 2 F5 F5
150 Watt High Pressure Sodium 150 240 2 F5 F5
120 HX-HPF 2.00 1.70 188 277 1 F5 F4
208 HX-HPF 1.15 0.95 188 480 2 F3 F3
240 HX-HPF 1.00 0.85 188 120 1 — F5
277 HX-HPF 0.85 0.72 188 208 2 — F3
480 HX-HPF 0.50 0.47 189 175 240 2 — F3
100 Watt Pulse Start Metal Halide 277 1 — F2
120 HX-HPF 1.20 1.15 130 480 2 — F2
208 HX-HPF 0.70 0.70 130 120 1 — F9
240 HX-HPF 0.61 0.58 130 208 2 — F6
277 HX-HPF 0.55 0.50 130 200 240 2 — F5
480 HX-HPF 0.30 0.35 140 277 1 — F4
150 Watt Pulse Start Metal Halide 480 2 — F2
120 HX-HPF 1.75 1.60 188
208 HX-HPF 1.30 1.00 188
240 HX-HPF 0.85 0.80 188
277 HX-HPF 0.77 0.70 188
480 C.W.A. 0.45 0.42 185
175 Watt Pulse Start Metal Halide
120 C.W.A. 0.90 1.78 199
208 C.W.A. 0.50 1.08 199
240 C.W.A. 0.35 0.89 199
277 C.W.A. 0.30 0.76 199 Fuses are filled with non-combustible granular material.
480 C.W.A. 0.25 0.50 213 Fuse Kit includes fuse, fuse block, wire, mounting screws
200 Watt Pulse Start Metal Halide and connectors. All mounting hoods have provisions
120 C.W.A. 2.10 2.00 238 for easy field installation of fuses in fixtures.
208 C.W.A. 1.15 1.25 238
240 C.W.A. 1.10 1.00 238
277 C.W.A. .75 .85 238
480 C.W.A. .58 .50 237

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.

1014 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaire Dimensions
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

Lighting
Lighting: Enclosed and Gasketed — Area — HID
Pendant Mount 25° Angle Stanchion Mount Ceiling Mount

Wall Mount Fixture with 8” Refractor

Fixture with Guard and Polyester Reflector Fixture with 12” Refractor

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1015


© September 2010
Mercmaster™ II HID Luminaire Photometric Data
150 W HPS
UNILETS® for Use with Threaded Metal Conduit.

* Photometric data is based on fixtures with For candlepower values of fixtures with other
150-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers; for
(16,000 lumen). 100 W (9,500 lumen) HPS lamp – 0.594; for 70 W
(6,400 lumen) HPS lamp – 0.40; for 50 W (4,000
lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Total Luminaire Efficiency = 86.1%


CIE Type - Semi-Direct REPORT NUMBER: LP15LGG
Spacing 150 W High Pressure Sodium fixture with Globe only *
Plane Criteria
Lighting

0-180 2.82 Coefficients of Utilization - Zonal Cavity Method


90-270 2.82 Effective Floor Cavity Reflectance 0.20
Diagonal 2.82 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 57 57 57 53
0-10 50.74 1 81 74 69 64 75 69 64 59 59 55 51 50 47 44 42 39 37 33
10-20 164.55 2 71 62 54 47 65 57 50 44 49 43 38 41 36 32 33 30 27 23
Lighting: Enclosed and Gasketed — Area — HID

20-30 310.47 3 64 52 44 37 58 48 41 34 41 35 30 34 29 25 28 24 20 17
30-40 611.05 4 57 45 36 30 53 42 34 28 35 29 24 29 24 20 24 19 16 13
40-50 961.13 5 52 40 31 24 48 37 29 23 31 24 19 26 20 16 21 16 13 10
50-60 1308.18 6 48 35 26 20 44 32 25 19 27 21 16 23 17 13 18 14 11 8
60-70 1542.35 7 44 31 23 17 40 29 21 16 24 18 14 20 15 11 16 12 9 7
70-80 1716.10 8 40 28 20 15 37 26 19 14 22 16 12 18 13 10 15 11 8 6
80-90 1799.18 9 38 25 18 13 35 24 17 12 20 14 10 17 12 8 14 10 7 5
90-100 1802.19 10 35 23 16 11 32 22 15 11 18 13 9 15 11 7 13 9 6 4
100-110 1676.86
110-120 1379.11 Zonal Lumen Summary
120-130 441.46 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 9.61 0-30 525.75 3.3 3.8 90-120 4858.16 30.4 35.3
140-150 3.33 0-40 1136.81 7.1 8.3 90-130 5299.62 33.1 38.5
150-160 0.74 0-60 3406.12 21.3 24.7 90-150 5312.56 33.2 38.5
160-170 0.00 0-90 8463.75 52.9 61.4 90-180 5313.30 33.2 38.6
170-180 0.00 0-180 13777.05 86.1 100.0

Total Luminaire Efficiency = 73.6%


CIE Type - Direct REPORT NUMBER: LP15LST
Spacing 150 W High Pressure Sodium fixture with Standard Dome Reflector *
Plane Criteria
0-180 1.46 Coefficients of Utilization - Zonal Cavity Method
90-270 1.46 Effective Floor Cavity Reflectance 0.20
Diagonal 1.68 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 88 88 88 88 86 86 86 86 82 82 82 78 78 78 75 75 75 73
0-10 266.98 1 79 76 72 69 77 74 71 68 71 68 66 68 66 64 65 64 62 60
10-20 799.41 2 71 65 59 55 69 63 58 54 61 57 53 58 55 52 56 53 50 49
20-30 1337.05 3 64 56 49 44 62 55 49 44 52 47 43 50 46 42 48 45 41 40
30-40 1732.06 4 58 49 42 36 57 48 41 36 46 40 36 44 39 35 42 38 35 33
40-50 2067.60 5 53 43 36 31 52 42 35 30 40 35 30 39 34 30 38 33 29 28
50-60 2317.60 6 49 38 31 26 47 38 31 26 36 30 26 35 30 25 34 29 25 24
60-70 2210.81 7 45 34 27 23 44 34 27 23 33 27 22 31 26 22 30 26 22 20
70-80 866.77 8 42 31 24 20 40 31 24 20 30 24 20 29 23 19 28 23 19 18
80-90 145.09 9 39 28 22 18 38 28 22 18 27 21 17 26 21 17 25 21 17 16
90-100 14.46 10 36 26 20 16 35 26 20 16 25 19 16 24 19 16 23 19 15 14
100-110 8.75
110-120 7.93 Zonal Lumen Summary
120-130 4.51 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 2.16 0-30 2403.44 15.0 20.4 90-120 31.14 0.2 0.3
140-150 0.48 0-40 4135.50 25.8 35.1 90-130 35.65 0.2 0.3
150-160 0.00 0-60 8520.70 53.3 72.3 90-150 38.29 0.2 0.3
160-170 0.00 0-90 11743.37 73.4 99.7 90-180 38.29 0.3 0.3
170-180 0.00 0-180 11781.65 73.6 100.0

1016 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaire Photometric Data
150 W HPS
UNILETS® for Use with Threaded Metal Conduit.

* Photometric data is based on fixtures with For candlepower values of fixtures with other
150-watt clear High Pressure Sodium lamp HPS lamps, use the following multipliers; for
(16,000 lumen). 100 W (9,500 lumen) HPS lamp – 0.594; for 70 W
(6,400 lumen) HPS lamp – 0.40; for 50 W (4,000
lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Total Luminaire Efficiency = 73.1%


CIE Type - Direct REPORT NUMBER: LP15LAN
Spacing 150 W High Pressure Sodium fixture with 30° Angle Dome Reflector *
Plane Criteria

Lighting
0-180 2.06 Coefficients of Utilization - Zonal Cavity Method
90-270 1.58 Effective Floor Cavity Reflectance 0.20
Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 86 86 86 86 84 84 84 84 79 79 79 75 75 75 71 71 71 70
0-10 222.62 1 76 71 67 63 73 69 65 62 65 62 59 62 59 57 58 56 54 52
10-20 664.60 2 68 60 54 49 65 58 53 48 55 50 46 52 48 45 49 46 43 41

Lighting: Enclosed and Gasketed — Area — HID


20-30 1084.32 3 61 52 45 39 59 50 44 39 48 42 37 45 40 36 43 39 35 33
30-40 1536.55 4 55 45 38 32 53 44 37 32 42 36 31 39 34 30 37 33 29 27
40-50 1771.90 5 50 40 33 27 49 39 32 27 37 31 26 35 30 25 33 29 25 23
50-60 1771.51 6 46 36 28 23 45 35 28 23 33 27 22 31 26 22 30 25 21 20
60-70 1668.93 7 43 32 25 20 41 31 25 20 30 24 19 28 23 19 27 22 19 17
70-80 1422.36 8 40 29 22 18 38 28 22 17 27 21 17 26 21 17 25 20 16 15
80-90 994.54 9 37 26 20 16 36 26 20 16 25 19 15 24 19 15 23 18 15 13
90-100 432.23 10 35 24 18 14 33 24 18 14 23 17 14 22 17 13 21 16 13 12
100-110 104.58
110-120 20.99 Zonal Lumen Summary
120-130 1.21 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.04 0-30 1971.54 12.3 16.9 90-120 557.80 3.5 4.8
140-150 0.00 0-40 3508.09 21.9 30.0 90-130 559.01 3.5 4.8
150-160 0.00 0-60 7051.50 44.1 60.3 90-150 559.04 3.5 4.8
160-170 0.00 0-90 11137.33 69.6 95.2 90-180 559.04 3.5 4.8
170-180 0.00 0-180 11696.38 73.1 100.0

Total Luminaire Efficiency = 81.1%


REPORT NUMBER: LP15LJ
CIE Type - Semi-Direct
150 W High Pressure Sodium fixture with
Spacing
Plane Criteria 8” Prismatic Glass Reractor - NEMA Type V *
0-180 1.98 Coefficients of Utilization - Zonal Cavity Method
90-270 1.98 Effective Floor Cavity Reflectance 0.20
Diagonal 3.40 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 93 93 93 93 89 89 89 89 82 82 82 76 76 76 70 70 70 67
0-10 72.83 1 80 73 68 63 76 70 65 61 64 60 56 58 55 52 53 50 48 45
10-20 222.26 2 69 59 51 45 65 56 49 43 51 45 40 46 41 37 41 37 34 31
20-30 380.73 3 61 49 40 33 57 47 38 32 42 35 29 38 32 27 34 29 25 22
30-40 621.11 4 54 42 32 25 51 40 31 24 35 28 22 32 26 21 28 23 19 16
40-50 852.53 5 49 36 27 20 46 34 26 19 31 23 18 27 21 16 24 19 15 12
50-60 1765.29 6 45 32 23 16 42 30 22 16 27 20 14 24 18 13 21 16 12 10
60-70 3192.58 7 41 28 20 14 38 27 19 13 24 17 12 24 15 11 19 14 10 8
70-80 2366.61 8 38 25 17 12 36 24 16 11 22 15 10 19 14 9 17 12 8 6
80-90 1230.65 9 35 23 15 10 33 22 15 10 20 13 9 18 12 8 16 11 7 5
90-100 450.14 10 33 21 14 9 31 20 13 9 18 12 8 16 11 7 15 10 6 5
100-110 712.41
110-120 499.15 Zonal Lumen Summary
120-130 323.44 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 185.00 0-30 675.83 4.2 5.2 90-120 1661.70 10.4 12.8
140-150 81.31 0-40 1296.93 8.1 10.0 90-130 1985.14 12.4 15.3
150-160 21.08 0-60 3914.76 24.5 30.2 90-150 2251.45 14.1 15.3
160-170 2.81 0-90 10704.60 66.9 82.5 90-180 2275.34 14.2 17.5
170-180 0.00 0-180 12979.94 81.1 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1017


© September 2010
Mercmaster™ II HID Luminaire Photometric Data
175 W PSMH
UNILETS® for Use with Threaded Metal Conduit.

* Photometric data is based on fixtures with For candlepower values of fixtures with other
175-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers:
(17,500 lumen). for 250 W (23,750 lumen) PSMH lamp – 1.36;
for 100 W (8,500 lumen) PSMH lamp – 0.49.
For candlepower values of fixture with guard,
multiply by 0.95.

Total Luminaire Efficiency = 75.4%


CIE Type - General Diffuse REPORT NUMBER: LP17PGG
Spacing 175 W Pulse Start Metal Halide fixture with Globe only *
Plane Criteria
Lighting

0-180 n/a Coefficients of Utilization - Zonal Cavity Method


90-270 n/a Effective Floor Cavity Reflectance 0.20
Diagonal n/a % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 82 82 82 82 77 77 77 77 66 66 66 57 57 57 48 48 48 44
0-10 42.67 1 70 65 60 55 65 60 56 52 51 47 44 42 40 37 35 33 31 27
10-20 151.27 2 62 54 47 42 57 50 44 39 42 37 33 35 31 28 28 25 22 19
Lighting: Enclosed and Gasketed — Area — HID

20-30 305.99 3 55 46 38 33 51 42 36 30 35 30 26 29 25 21 23 20 17 14
30-40 587.79 4 50 40 32 26 46 37 30 24 31 25 21 25 21 17 20 16 13 11
40-50 880.58 5 46 35 27 22 42 32 25 20 27 21 17 22 17 14 17 14 11 8
50-60 1114.51 6 42 31 23 18 38 28 22 17 24 18 14 20 15 12 15 12 9 7
60-70 1306.71 7 38 27 20 15 35 25 19 14 21 16 12 18 13 10 14 10 8 6
70-80 1568.03 8 35 25 18 13 32 23 17 12 19 14 10 16 12 9 13 9 7 5
80-90 1720.24 9 33 22 16 12 30 21 15 11 17 13 9 14 10 7 12 8 6 4
90-100 1797.50 10 31 20 14 10 28 19 13 9 16 11 8 13 9 7 11 7 5 3
100-110 1750.20
110-120 1559.14 Zonal Lumen Summary
120-130 391.09 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 7.81 0-30 499.93 2.9 3.8 90-120 5106.84 29.2 38.7
140-150 3.19 0-40 1087.72 6.2 8.2 90-130 5497.93 31.4 41.7
150-160 0.61 0-60 3082.80 17.6 23.4 90-150 5508.93 31.5 41.7
160-170 0.18 0-90 7677.78 43.9 58.2 90-180 5509.71 31.5 41.8
170-180 0.00 0-180 13187.48. 75.4 100.0

Total Luminaire Efficiency = 63.8%


CIE Type - Direct REPORT NUMBER: LP17PST
Spacing 175 W Pulse Start Metal Halide fixture with Standard Dome Reflector *
Plane Criteria
0-180 1.50 Coefficients of Utilization - Zonal Cavity Method
90-270 1.50 Effective Floor Cavity Reflectance 0.20
Diagonal 1.66 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 76 76 76 76 74 74 74 74 71 71 71 68 68 68 65 65 65 64
0-10 271.72 1 69 66 63 61 67 65 62 60 62 60 58 59 57 56 57 55 54 53
10-20 817.50 2 62 57 52 48 61 56 51 48 53 50 47 51 48 46 49 47 45 43
20-30 1392.53 3 56 49 44 39 55 48 43 39 46 42 38 45 41 38 43 40 37 35
30-40 1749.97 4 51 43 37 33 50 42 37 33 41 36 32 39 35 32 38 34 31 30
40-50 2044.83 5 47 38 32 28 45 37 32 28 36 31 27 35 30 27 33 30 27 25
50-60 2121.25 6 43 34 28 24 42 33 28 24 32 27 23 31 27 23 30 26 23 22
60-70 1862.42 7 40 31 25 21 39 30 25 21 29 24 20 28 24 20 27 23 20 19
70-80 720.46 8 37 28 22 18 36 27 22 18 26 22 18 26 21 18 25 21 18 16
80-90 141.89 9 34 25 20 16 33 25 20 16 24 19 16 23 19 16 23 19 16 15
90-100 14.66 10 32 23 18 15 31 23 18 15 22 18 14 22 17 14 21 17 14 13
100-110 8.28
110-120 9.57 Zonal Lumen Summary
120-130 5.69 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 3.14 0-30 2481.75 14.2 22.2 90-120 32.51 0.2 0.3
140-150 2.17 0-40 4231.72 24.2 37.9 90-130 38.20 0.2 0.3
150-160 1.71 0-60 8397.80 48.0 75.2 90-150 43.51 0.2 0.3
160-170 1.70 0-90 11122.57 63.6 99.6 90-180 47.28 0.3 0.4
170-180 0.36 0-180 11169.85 63.8 100.0

1018 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ II HID Luminaire Photometric Data
175 W PSMH
UNILETS® for Use with Threaded Metal Conduit.

* Photometric data is based on fixtures with For candlepower values of fixtures with other
175-watt clear Pulse Start Metal Halide lamp PSMH lamps, use the following multipliers:
(17,500 lumen). for 250 W (23,750 lumen) PSMH lamp – 1.36;
for 100 W (8,500 lumen) PSMH lamp – 0.49.
For candlepower values of fixture with guard,
multiply by 0.95.

Total Luminaire Efficiency = 61.6%


CIE Type - Direct REPORT NUMBER: LP17PAN
Spacing 175 W Pulse Start Metal Halide fixture with 30° Angle Dome Reflector *
Plane Criteria

Lighting
0-180 2.02 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.58 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 73 73 73 73 71 71 71 71 67 67 67 64 64 64 61 61 61 59
0-10 221.01 1 64 61 57 54 62 59 56 53 56 53 51 53 51 49 50 49 47 45
10-20 674.48 2 58 52 46 42 56 50 45 42 47 44 40 45 42 39 43 40 38 36

Lighting: Enclosed and Gasketed — Area — HID


20-30 1111.79 3 52 45 39 34 50 43 38 34 41 36 33 39 35 32 37 34 31 29
30-40 1519.14 4 47 39 33 28 46 38 32 28 36 31 27 34 30 27 33 29 26 24
40-50 1697.13 5 43 34 28 24 42 34 28 24 32 27 23 30 26 23 29 25 22 21
50-60 1644.77 6 40 31 25 20 38 30 24 20 29 24 20 27 23 20 26 22 19 18
60-70 1457.83 7 37 28 22 18 35 27 22 18 26 21 17 25 20 17 24 20 17 15
70-80 1248.84 8 34 25 20 16 33 25 19 16 24 19 15 23 18 15 22 18 15 14
80-90 814.94 9 32 23 18 14 31 23 17 14 22 17 14 21 17 13 20 16 13 12
90-100 280.33 10 30 21 16 13 29 21 16 12 20 15 12 19 15 12 18 15 12 11
100-110 87.54
110-120 16.66 Zonal Lumen Summary
120-130 1.25 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.06 0-30 2007.28 11.5 18.6 90-120 384.53 2.2 3.6
140-150 0.06 0-40 3526.41 20.2 32.7 90-130 385.77 2.2 3.6
150-160 0.00 0-60 6868.32 39.2 63.7 90-150 385.89 2.2 3.6
160-170 0.00 0-90 10389.94 59.4 96.4 90-180 385.89 2.2 3.6
170-180 0.00 0-180 10775.83 61.6 100.0

Total Luminaire Efficiency = 73.9%


REPORT NUMBER: LP17PJ
CIE Type - Semi-Direct
175 W Pulse Start Metal Halide fixture with Globe and
Spacing
Plane Criteria 8” Prismatic Glass Reractor - NEMA Type V *
0-180 2.08 Coefficients of Utilization - Zonal Cavity Method
90-270 2.08 Effective Floor Cavity Reflectance 0.20
Diagonal 3.78 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 85 85 85 85 82 82 82 82 75 75 75 69 69 69 64 64 64 61
0-10 58.60 1 72 66 61 56 68 63 58 54 57 54 50 52 49 46 47 45 43 40
10-20 179.87 2 62 53 46 39 59 51 44 38 46 40 35 41 36 32 37 33 30 27
20-30 316.74 3 55 44 35 29 51 41 34 28 37 31 25 33 28 23 30 25 21 19
30-40 543.99 4 49 37 28 22 46 35 27 21 31 24 19 28 22 17 25 20 16 13
40-50 726.99 5 44 32 23 17 41 30 22 16 27 20 15 24 18 14 21 16 12 10
50-60 1445.41 6 40 28 20 14 37 26 19 13 24 17 12 21 15 11 19 14 10 8
60-70 3661.34 7 37 25 17 12 34 23 16 11 21 15 10 19 13 9 17 12 8 6
70-80 2432.42 8 34 22 15 10 32 21 14 9 19 13 8 17 12 8 15 10 7 5
80-90 1351.63 9 31 20 13 8 30 19 13 8 17 11 7 16 10 7 14 9 6 4
90-100 477.79 10 29 18 12 7 28 18 11 7 16 10 6 14 9 6 13 8 5 4
100-110 717.26
110-120 474.07 Zonal Lumen Summary
120-130 293.44 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 163.08 0-30 555.22 3.2 4.3 90-120 1669.13 9.5 12.9
140-150 70.40 0-40 1099.21 6.3 8.5 90-130 1962.57 11.2 15.2
150-160 18.48 0-60 3271.60 18.7 25.3 90-150 2196.06 12.5 15.2
160-170 2.58 0-90 10717.00 61.2 82.9 90-180 2217.10 12.7 17.1
170-180 0.00 0-180 12934.11 73.9 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1019


© September 2010
Mercmaster™ II HID Luminaire Isofootcandle Data
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

HPS Lamp Mounting Height Horizontal Distance from Mounting Point (Ft/M)
Wattage (Ft/M) 0/0 5/1.5 10/3.0 15/4.6 20/6.1 25/7.6 30/9.1 35/10.7 40/12.2 45/13.7 50/15.2
Mercmaster II, High Pressure Sodium, No Reflector, No Guard
70 Watt – 5,800 Lumen
Lighting

100 Watt – 9,500 Lumen


150 Watt – 16,000 Lumen

Footcandle Chart (Initial Horiz. FTC)

8/2.4 .60 2.70 1.50 .73 .38 .21 .13 .08 .06 .04 .03
10/3.0 .39 1.70 1.30 .72 .40 .24 .15 .10 .07 .05 .04
Lighting: Enclosed and Gasketed — Area — HID

70 12/3.7 .27 1.10 1.10 .68 .41 .26 .17 .11 .08 .06 .04
15/4.6 .17 .66 .81 .60 .39 .26 .18 .13 .09 .07 .05
20/6.1 .10 .37 .43 .40 .33 .25 .18 .13 .10 .08 .06
8/2.4 1.00 4.80 2.70 1.20 .62 .35 .21 .14 .10 .07 .05
10/3.0 .64 2.80 2.20 1.30 .67 .40 .25 .16 .11 .08 .06
100 12/3.7 .44 1.80 1.80 1.30 .71 .42 .28 .18 .13 .09 .07
15/4.6 .28 1.10 1.30 .97 .70 .45 .30 .21 .15 .11 .08
20/6.1 .16 .59 .69 .70 .55 .42 .32 .23 .17 .13 .10
8/2.4 2.50 8.30 4.60 2.20 1.10 .62 .38 .25 .17 .12 .09
10/3.0 1.60 5.40 4.00 2.20 1.20 .71 .44 .29 .20 .14 .11
150 12/3.7 1.10 4.20 3.30 2.00 1.20 .76 .49 .33 .23 .17 .12
15/4.6 .72 2.10 2.40 1.80 1.20 .79 .54 .38 .27 .20 .15
20/6.1 .40 1.10 1.30 1.30 1.00 .73 .54 .40 .30 .23 .18

Mercmaster II, High Pressure Sodium, With Reflector, No Guard


70 Watt – 5,800 Lumen
100 Watt – 9,500 Lumen
150 Watt – 16,000 Lumen

Footcandle Chart (Initial Horiz. FTC)


8/2.4 14.80 10.00 3.80 1.50 .55 .15 .05 .03 .02 .01 .01
10/3.0 9.50 7.70 3.70 1.60 .74 .32 .12 .05 .03 .02 .01
70 12/3.7 6.60 6.60 3.30 1.50 .87 .46 .18 .10 .05 .02 .02
15/4.6 4.20 4.20 2.70 1.70 .94 .56 .33 .18 .10 .06 .03
20/6.1 2.40 2.50 1.90 1.30 .92 .62 .41 .28 .18 .12 .08
8/2.4 21.90 16.80 6.30 2.40 .86 .28 .08 .05 .03 .02 .01
10/3.0 14.00 12.40 6.00 2.70 1.20 .53 .19 .07 .04 .03 .02
100 12/3.7 9.70 9.40 5.50 2.80 1.40 .73 .36 .20 .13 .04 .03
15/4.6 6.20 6.70 4.40 2.70 1.60 .90 .53 .33 .19 .11 .05
20/6.1 3.50 4.30 3.10 2.20 1.50 1.0 .68 .44 .30 .21 .13
8/2.4 36.90 27.80 10.50 3.80 1.30 .35 .14 .08 .04 .03 .02
10/3.0 23.60 20.80 10.10 4.40 2.00 .78 .29 .11 .07 .04 .03
150 12/3.7 16.40 15.80 9.20 4.60 2.20 1.20 .54 .30 .16 .06 .04
15/4.6 10.50 11.60 7.50 4.50 2.60 1.50 .86 .42 .26 .16 .08
20/6.1 5.90 7.20 5.20 3.70 2.50 1.70 1.10 .73 .50 .32 .19

1020 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ Jr. Luminaires
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

With Globe: 70 W: † With Refractor (NEMA V): 150 W: †


35 W, 50 W: † Class I, Division 2, Groups A, B, C, D 35 W, 50 W, 70 W, 100 W: † Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E ‡, F Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G Class II, Division 1 and 2, Groups E ‡, F, G
Class III 100 W, 150 W: † Class III
Class I, Division 2, Groups A, B, C, D

Applications
• Inexpensive HID integrally ballasted fixture for use in hazardous
locations – inexpensive to buy and inexpensive to operate (uses
one-fifth as much electrical energy as incandescent and three-
quarters as much as fluorescent).

Lighting
• Enclosed and gasketed HID lighting fixtures for use in tunnels,
walkways, bridges, storage facilities, processing plants, parking
lots, foundries, manufacturing plants, power plants and other
locations where moisture, dirt, dust or corrosive atmospheres
are encountered.
Features
• “Wireless” design. Threading of fixture unit onto mounting hood

Lighting: Enclosed and Gasketed — Area — HID


makes electrical connection. Only wiring required is attaching
two wires to connection block in mounting hood.
• Safe, easy servicing without disconnecting any wiring. Illustrated Feature
“Wireless” fixture unit easily threads off mounting hood for Conversion from Appleton V-51 incandescent installation to
convenient servicing.
HID Mercmaster Jr. is easy and fast.
• Quick, easy conversion from Appleton V-51® incandescent
installation to Mercmaster Jr. HID. Just remove V-51® fixture
unit and thread Mercmaster Jr. fixture unit onto existing V-51®
mounting hood.
• Choice of mounting hoods. Standard fixtures in pendant, ceiling,
outlet box, wall and stanchion mountings.
• Standard pendant mounting hood for rigid or flexible mounting. Step No. 1:
Balanced round design automatically hangs plumb when used After power is shut off, remove present
with flexible hanger. incandescent V-51 fixture unit from
• Unitized construction reduces installation and maintenance existing V-51 mounting hood.
costs.
• Ballast has standard non-PCB biodegradable capacitors.
• Medium base socket is furnished with 392 °F/200 °C leads,
prewired to the ballast. Porcelain socket assures trouble-free
operation in high ambient installations.
• Prismatic glass globe or glass refractor is standard and threads
directly into fixture housing. Eliminates glare and provides
uniform light distribution.
• Fiberglass reinforced polyester reflector for exceptionally severe
corrosive atmospheres. Vented for cooler, dirt-free operation,
increased lumen output.
Standard Materials
• Mounting hoods: copperfree (4/10 of 1% max.) aluminum or Step No. 2:
malleable iron Thread Mercmaster Jr. HID fixture unit
• Ballast bodies: copperfree (4/10 of 1% max.) aluminum onto existing V-51 mounting hood —
• Guards: copperfree (4/10 of 1% max.) aluminum or steel and conversion is completed.
• Reflectors: fiberglass reinforced polyester or porcelain
• Globe: 35 W-100 W, threaded prismatic glass and threaded
polycarbonate; 150 W, threaded heat-resistant prismatic glass
• Refractor: heat-resistant prismatic glass
Standard Finishes
• Ballast bodies, aluminum guard and VMA, VXHA-A, OBVW1-A,
OBV1-A, JBW1-A, JB1-A, GSW2 and MS mounting hoods:
epoxy powder coat finish, electrostatically applied for complete,
uniform surface protection Options
• VA, VXHA, OBVW1, OBV1, GS-2, JBW1, and JB1 malleable iron • Fuses for fixtures, factory installed. Add suffix -F.
mounting hoods: triple coat – (1) zinc electroplate; (2) chromate;
and (3) epoxy powder coat Certifications and Compliances
• Steel guard: zinc electroplate • UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10444

† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1021


© September 2010
Mercmaster™ Jr. Luminaire Classified Area Suitability and Ballast Data
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

With Globe: 70 W: † With Refractor (NEMA V): 150 W: †


35 W, 50 W: † Class I, Division 2, Groups A, B, C, D 35 W, 50 W, 70 W, 100 W: † Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E ‡, F Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G Class II, Division 1 and 2, Groups E ‡, F, G
Class III 100 W, 150 W: † Class III
Class I, Division 2, Groups A, B, C, D

Thermal Suitability Example:


Table at below shows maximum operating temperatures of • Gasoline (56-60 octane)
Mercmaster Jr. fixtures for Class I, Division 2, in a 104 °F/40 • Fixture with Globe and Reflector
°C ambient. Per NEC 500.8(B)(4), the temperature marking on To determine Mercmaster Jr. thermal suitability for the above
fixtures shall not exceed the ignition temperature of the specific example:
Lighting

gas or vapor to be encountered. NEC 500.8(B)(4) states that (1) Check the Thermal Suitability on the following page for ignition
these markings (Identification Numbers) “marked on equipment temperature of gas or vapor to be encountered. It reveals that
nameplates shall be in accordance with Table NEC 500.8(C).” This 56-60 octane gasoline has an ignition temperature of
NEC table is duplicated, as it applies to Appleton Mercmaster Jr. 536 °F/280 °C.
fixtures, in the table below. (2) Look in table below for fixtures under “With Globe and
Reflector” that do not exceed the 536 °F/280 °C ignition
As shown, the higher the Temperature Identification Number, the temperature of the gasoline.
cooler the fixture operates. Keep this in mind when selecting a (3) Select the best fixture for your purpose. The 35 W, 50 W, 70 W
Lighting: Enclosed and Gasketed — Area — HID

fixture for a specific gas or vapor. or 100 W fixture with globe and reflector is acceptable because
none of these fixture lamp surfaces exceed the 536 °F/280 °C
ignition temperature of the gasoline.

Temperature Identification Numbers

Class I, Division 2, Groups A, B, C and D Class II, Division 1 and 2, Groups E, F and G
With Globe or with Globe and Reflector With 8” Refractor With Globe, with Globe and Reflector, or with 8” Refractor
Lamp Nameplate Temperature Nameplate Temperature Nameplate Temperature
Watts Marking Range (°F/°C) Marking Range (°F/°C) Marking Range (°F/°C) Groups
35 T4 250-275 / 121-135 T4 250-275 / 121-135 T4C 214-248 / 101-120 E, F, G
50 T2D 394-419 / 201-215 T3 358-392 / 181-200 T3C 277-320 / 136-160 E, F, G
70 T2B 448-500 / 231-260 T2C 421-446 / 216-230 T3B 322-329 / 161-165 E, F, G ➊
100 T2A 502-536 / 261-280 T2B 448-500 / 231-260 — — E, F, G ➋
150 T2 538-572 / 281-300 T2A 502-536 / 261-280 — — —

Ambient Suitability of Mercmaster Jr. Fixtures Electrical Specifications (Reactor Ballasts)


All fixtures suitable for operation at -40 °F/-40 °C.
Line Current in Amperes
35W 50W 70W 100W 150W Lamp Line Voltage Input
Watts 60 Hz Starting HPF Operating HPF Watts
104 °F/ 104 °F/ 77 °F/ 77 °F/ 77 °F/
40 °C 40 °C 25 °C 25 °C 25 °C 35 120 0.41 0.38 43
50 120 0.62 0.56 60
Retrofits Incandescent Fixtures Easily and Quickly 70 120 0.70 0.73 82
• 35 W HPS Comparable to 100/150 W Incandescent Lamp 100 120 1.10 1.00 115
• 50 W HPS Comparable to 200 W Incandescent Lamp 150 120 1.70 1.50 170
• 70 W HPS Comparable to 300 W Incandescent Lamp
• 100 W HPS Comparable to 1.5 300 W Incandescent Lamp ➌
• 150 W HPS Comparable to 2.5 300 W Incandescent Lamp ➌
Optional Factory-Installed Fuses – Add Suffix -F
Available as a factory installed item with Mercmaster Jr. fixtures.

➊70W suitable for Groups E and F with globe; suitable for Groups E, F, and G with refractor.
➋ 100W suitable for Groups E, F and G with refractor only.
➌ These are guidelines only. Light distribution and other factors must be taken into consideration.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.

1022 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ Jr. Luminaires
35 W, 50 W, 70 W, 100 W, 150 W HPS
Complete with Mounting Hood. Medium Base Socket. High Power Factor (Min. P.F. 90%). Integral Ballast for 120 V Line Operation.

With Globe: 70 W: † With Refractor (NEMA V): 150 W: †


35 W, 50 W: † Class I, Division 2, Groups A, B, C, D 35 W, 50 W, 70 W, 100 W: † Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E ‡, F Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G Class II, Division 1 and 2, Groups E ‡, F, G
Class III 100 W, 150 W: † Class III
Class I, Division 2, Groups A, B, C, D

With Globe, With Refractor ANSI Hub Size Catalog Number ➎


Less Guard (NEMA V) Lamp Watts Lamp Type (Inches) With Globe, Less Guard With Refractor (NEMA V)
Pendant — Aluminum mounting hood and ballast body. One Hub, Rigid or Flexible Mounting
3/4 MA3575-120 MA3575J-120
35 S76

Lighting
1 MA3510-120 MA3510J-120
3/4 MA5075-120 MA5075J-120
50 S68
1 MA5010-120 MA5010J-120
3/4 MA7075-120 MA7075J-120
70 S62
1 MA7010-120 MA7010J-120
3/4 MA1075-120 MA1075J-120
100 S54
1 MA1010-120 MA1010J-120
3/4 MA1575-120 MA1575J-120

Lighting: Enclosed and Gasketed — Area — HID


150 S55
1 MA1510-120 MA1510J-120
Ceiling — Aluminum mounting hood and ballast body. Five Hubs, Four Close-Up Plugs
3/4 MC3575-120 MC3575J-120
35 S76
1 MC3510-120 MC3510J-120
3/4 MC5075-120 MC5075J-120
50 S68
1 MC5010-120 MC5010J-120
3/4 MC7075-120 MC7075J-120
70 S62
1 MC7010-120 MC7010J-120
3/4 MC1075-120 MC1075J-120
100 S54
1 MC1010-120 MC1010J-120
3/4 MC1575-120 MC1575J-120
150 S55
1 MC1510-120 MC1510J-120
Wall ➌ — Malleable iron mounting hood and aluminum ballast body. Gasket and screws furnished with fixture. Fits GSU Cast Boxes

35 S76 — MGSW35-120 MGSW35J-120


50 S68 — MGSW50-120 MGSW50J-120
70 S62 — MGSW70-120 MGSW70J-120
100 S54 — MGSW10-120 MGSW10J-120
150 S55 — MGSW15-120 MGSW15J-120

Wall ➋➌ — Class I, Division 2 only. Aluminum mounting hood and ballast body. Gasket and screws furnished with fixture. Fits JBX Cast Boxes

35 S76 — MJBW35-120 MJBW35J-120


50 S68 — MJBW50-120 MJBW50J-120
70 S62 — MJBW70-120 MJBW70J-120
100 S54 — MJBW10-120 MJBW10J-120
150 S55 — MJBW15-120 MJBW15J-120

25° Stanchion ➍ — Aluminum mounting hood and ballast body. One hub
1-1/4 MS35125-120 MS35125J-120
35 S76
1-1/2 MS35150-120 MS35150J-120
1-1/4 MS50125-120 MS50125J-120
50 S68
1-1/2 MS50150-120 MS50150J-120
1-1/2 MS70125-120 MS70125J-120
70 S62
1-1/2 MS70150-120 MS70150J-120
1-1/4 MS10125-120 MS10125J-120
100 S54
1-1/2 MS10150-120 MS10150J-120
1-1/4 MS15125-120 MS15125J-120
150 S55
1-1/2 MS15150-120 MS15150J-120

‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
 All fixtures on this page comply with UL Standard 844 except MJBW Wall Mount Fixture, which is not suitable for Class II, Division 1.
 Using cast outlet box with Wall Mount Fixture provides the following clearances: for the globe – JBX box, 1-5/8” from wall; GSU box, 2” from wall; for the
refractor – JBX box, 15/16” from wall; GSW box, 1-5/16” from wall. Reflectors cannot be used with the wall mount fixtures.
 Stanchion Mount can be used with standard dome or 30° angle reflector.
 To order fixture with guard, add -G before voltage (example: MA3575G-120).

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1023


© September 2010
Mercmaster™ Jr. Luminaires
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

With Globe: 70 W: † With Refractor (NEMA V): 150 W: †


35 W, 50 W: † Class I, Division 2, Groups A, B, C, D 35 W, 50 W, 70 W, 100 W: † Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E ‡, F Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G Class II, Division 1 and 2, Groups E ‡, F, G
Class III 100 W, 150 W: † Class III
Class I, Division 2, Groups A, B, C, D

Lamp ANSI Catalog Number


With Globe With 8” Refractor Description Watts Lamp Type With Globe ➊ With 8” Refractor
Outlet Box Fixture
35 S76 MOB35-120 MOB35J-120
Lighting

Aluminum ballast housing, complete with


aluminum mounting hood. Epoxy clad. 50 S68 MOB50-120 MOB50J-120
70 S62 MOB70-120 MOB70J-120
Use with SEH and 3-1/4” or 4” Octagonal
Outlet Box. Fixture furnished with mounting 100 S54 MOB10-120 MOB10J-120
plate and gasket. Octagonal boxes not
suitable for classified locations. 150 S55 MOB15-120 MOB15J-120
Lighting: Enclosed and Gasketed — Area — HID

Lamp ANSI
Watts Lamp Type Catalog Number
Fixture Units
Ballast body with globe (VPGL-1 with 35 S76 35 MUL35-120
W, 50 W, 70W and 100W and VPGL-1HR
with 150 W). Use with mounting hoods on S68 50 MUL50-120
following page or any V-51 series mounting S62 70 MUL70-120
hood. Polyester or porcelain reflector and
aluminum guard are available. High power S54 100 MUL100-120
factor (min. P.F. 90%). Ballast provides 120 V
line operation. S55 150 MUL150-120

Ballast Bodies
S76 35 MBL35-120
Use with mounting hoods on following
page or any V-51 series mounting hood and S68 50 MBL50-120
with refractor or globe listed. Order other
S62 70 MBL70-120
accessories below as desired. High power
factor (min. P.F. 90%). Ballast provides 120 V S54 100 MBL100-120
line operation.
S55 150 MBL150-120

‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
➊ Order JBX or GSU box on following page.

1024 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ Jr. Luminaire Mounting Hoods and Outlet Boxes
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

Catalog Number
Hub Size
Wall Ceiling (Inches) Aluminum Malleable Iron
Pendant Mounting Furnished with connection block, gasket and screws

Lighting
1/2 — VA50
3/4 VMA75 VA75
VMA VA 1 VMA100 VA100
Ceiling Mounting Five Hubs. Furnished with connection block, gasket, screws and four close-up plugs
1/2 VXHA50-A VXHA50
3/4 VXHA75-A VXHA75

Lighting: Enclosed and Gasketed — Area — HID


VXHA 1 VXHA100-A VXHA100
Cast/Outlet Box Mounting Furnished with connection block, mounting plate and gasket. Octagonal outlet box not suitable for classified
locations. Fits SEH and 3-1/4” or 4” Octagonal Box ➋
Wall ➎ OBVW1-A OBVW1
Ceiling OBV1-A OBV1
OBVW OBV

GS Round Base – Fits GSU Cast Boxes ➌ ➍ Furnished with connection block, gasket and screws
Wall ➎ — GSW2
Ceiling — GS2
GS
GSW
JB Round Base – Fits JBX Cast Boxes ➌ ➍ Furnished with connection block, gasket and screws
Wall ➎ JBW1-A JBW1
Ceiling JB1-A JB1
JB
JBW
Stanchion Mounting ➏ 25° Stanchion furnished with connection block and screws.
1-1/4 MS-125 —
1-1/2 MS-150 —
MS
JBX Cast Conduit Outlet Boxes 
1/2 JBX50L-A —
Aluminum. 1-5/16” inside depth. Four tapped openings,
two close-up plugs and mounting lugs. Use with JBW 3/4 JBX75L-A —
wall mount fixture and JB round base mounting hoods
JBX
GSU Cast Conduit Outlet Box (Form 20) 
1/2 or 3/4 — GSU-20
Malleable iron. 1-3/4” inside depth. Four 3/4” hubs
with four 3/4” to 1/2” reducers, and three 1/2” close-up 1 — GSU-100
plugs. Use with GSW wall mount fixture and GS round
base mounting hoods
GSU-20 GSU-100

 Order SEH box from catalog section A and octagonal box from Section OB. To order fixture with guard, add G before voltage (example: MOB35G-120).
 Order JBX below. Using JBX Box with these fixtures and mounting hoods provides 15/16” clearance from wall with refractor and 1-5/8” clearance from wall
with globe.
 Order GSU below. Using GSU Box with these fixtures and mounting hoods provides 1-5/16” clearance from wall with refractor and 2” clearance from wall with
globe.
 Reflectors cannot be used with wall mount fixtures. See dimensions for globe or refractor clearance from wall for these fixtures.
➏ Stanchion mounting hood can be used with standard dome or 30° angle reflector.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1025


© September 2010
Mercmaster™ Jr. Luminaire Accessories
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

Description Catalog Number


Globes – 35 W-150 W
Clear Heat-Resistant Prismatic Glass VPGL-1HR
Polycarbonate (100W lamp max.) ➋ VPGL-2PL
Lighting

VPGL-1HR VPGL-2PL

IES/NEMA
Lighting: Enclosed and Gasketed — Area — HID

Description Light Distribution Distribution Curves Catalog Number


Refractors – 35 W-150 W

NEMA Type II LPJR-2CG

Closed Prismatic Glass 8” Refractors

NEMA Type V LPJR-5CG

Catalog Number
Description Porcelain Polyester
Reflectors – 35 W-150 W ➊
Standard (porcelain, 16” dia.; polyester, 16-1/4” dia.) LPR-25ST LPRP-25ST
30° Angle (porcelain, 12” dia.; polyester, 14-3/8” dia.) LPR-25AN LPRP-25AN

Standard 30° Angle

Description Catalog Number


Guards – 35 W-150 W
Copperfree Aluminum Guard VPGU-1

Steel Guard for 8” Refractors LPBG-8

VPGU-1 LPBG-8
Socket

35 W-150 W (Medium Base) JRS-100

Gasket

Globe Gasket, Silicone Rubber – 35W-150W VPGL-GK

➊ V-51 reflectors cannot be used with Mercmaster Jr. Fixtures.


➋ Do not use Polycarbonate Globes in ambients exceeding 77 °F/25 °C. These globes for burning in vertical base-up position only.

1026 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ Jr. Luminaire Dimensions
35 W, 50 W, 70 W, 100 W, 150 W
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

Lighting
MBL Ballast Body Fixture with 8” Refractor

Lighting: Enclosed and Gasketed — Area — HID


Fixture with Guard and Polyester Reflectors

VXHA Ceiling Mount VMA Pendant Mount

GSW Wall Mount ➊ and GS Ceiling Mount with GSU Box ➋

Stanchion Mount ❻ ➍ OBV Outlet Box Mount and Mounting Plate JBW Wall Mount ➊ with JBX Box ➋

➊ Mounting holes 9/32” diameter on 5-1/8” centers. Mounting plate is a separate piece furnished with outlet box mount fixture. The 2.75” dimension is for
mounting on 3-1/4” octagonal boxes and the 3.50” dimension is for 4” octagonal boxes.
➋ Wall mount fixtures provide the following wall clearances: with GSU box – 2” from wall with globe and 1-5/16” from wall with refractor; with JBX box – 1-5/8”
from wall with globe and 15/16” from wall with refractor. Reflectors cannot be used with wall mount fixtures.
➌ Order GSU or JBX box separately.
➍ Standard dome or 30° angle reflectors can be used with stanchion mount.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1027


© September 2010
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors are present under
conditions defined by the National Electrical Code as Class I,
Division 2
— Areas of low clearance, low ceiling heights or where fixture
weights must be minimized
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
Lighting

— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sewage treatment
— Parking garages
— Other areas where dust, water, dirt and rough usage are a
problem
Lighting: Enclosed and Gasketed — Area — LED/Induction

Features Certifications and Compliances


• Compact light-weight low profile design is suited for low • UL Standard: UL 1598, UL 1598A, UL 8750, UL 844
mounting heights. • CSA Standard: C22.2 No. 250, C22.2 No. 137
• Modular design allows scores of fixture component • cETLus Listed
combinations to meet installation needs. Uses same mounting Related Products
hoods as Mercmaster III.
• Fixture housing and mounting hoods are copperfree cast • Photocells for classified use are available, see PCD2 Series.
aluminum with baked epoxy finish. All exposed hardware is
stainless steel.
• Accommodates a wide range of voltages.
• Ambient: -40 ˚F to 131 ˚F / -40 ˚C to 55 ˚C
• Electrical: 120-277 Vac, 50/60 Hz; 347-480 Vac, 50/60 Hz
• Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies
servicing.
• All Mercmaster mounting hoods have provision for easy field
installation of fuses in fixtures (see Fixture Unit — Electrical
Specification).
Standard Materials
• Mounting hoods and bodies: cast copperfree (4/10 of 1% max.)
aluminum
• All hardware and catch assemblies: stainless steel
• Globes: polycarbonate
Standard Finishes
• Mounting hoods, bodies and guards: baked gray epoxy-clad
finish, electrostatically applied for complete uniform protection

1028 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Illustrated Features

Lighting
Heatsink Driver Assembly LED Chamber
Reliable heat transfer via the cast, epoxy Utilizing non-sparking components Protected by polycarbonate lens, allows
powder coat aluminum body. Provides avoiding the ignition of gases or vapors for easy maintenance access.
maximum heat dissipation from the LED that may be present (nA).
assembly to the outside environment.
Modular Plug between LED and driver.

Lighting: Enclosed and Gasketed — Area — LED/Induction


Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.

Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Fuses Cooler Operating Cone Hood
Two screws secure fuse kit to mounting Larger sloped surface sheds dusts, dirt
boss in any Mercmaster mounting hood. Electrical Protection and combustible fibers providing better
Fuse included. Ground wire provided to bond mounting heat dissipation.
hood to ballast housing.
Photocell Mounting Hood and Globe Gaskets
Available for all fixtures except cone and Safety Silicone rubber gaskets seals out
ceiling mount. Installs through knock-out Rounded heatsink edges prevent possible moisture, dirt and dust. Stays flexible,
in mounting hood. Provides continuous injury during installation. withstands high temperatures. Closure
ON-OFF dusk-to-dawn control. design assures uniform gasket
compression.

"Safety" High Hinge


Extra-high hinge provides additional
protection against accidental ballast
housing disengagement during installation
or maintenance.

Stainless Steel Latch Assembly


Captive, stainless steel latch assembly
bolt and nut closes securely, resists attack
of corrosive atmospheres. Swing-away
design simplifies servicing.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1029


© September 2010
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Order using catalog numbering guide below or select catalog number from tables on following pages.

Catalog Numbering Guide


MLED A 17 2 P 5 BU H1

Series: Light Level: Optical Assembly: Voltage:


MLED - 17 - 175 W P - Polycarbonate BU - Universal
Mercmaster Globe Voltages
LED 120-277 Vac,
50/60 Hz
BH - 347-480 Vac,
50/60 Hz

Mounting: Hub Size: Light Distribution: Options:


Lighting

A - Pendant 2 - 3/4” NPT 5 - NEMA 5 F - Fusing ➊


C - Ceiling 3 - 1” NPT H1 - Photocontrol 120 V
D - Pendant Cone 4 - 1-1/4” NPT H2 - Photocontrol 208 V
R - 90º Stanchion stanchion H3 - Photocontrol 240 V
S - 25º Stanchion 5 - 1-1/2” NPT H4 - Photocontrol 277 V
W - Wall stanchion
Lighting: Enclosed and Gasketed — Area — LED/Induction

Technical Data
Lamp Supply Wire Ambient
Light Level Equivalent Type Temperature (°F/°C) Temperature (°F/°C) Class I, Division 2
149/65 104/40 T4A
175 Watt PSMH LED
167/75 131/55 T4

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” # T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6

Temp. 664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
185
Range (˚ºF) 842 662 617 572 536 500 446 419 392 356 329 320 275 248 212

Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
85
Range (°C) 450 350 325 300 280 260 230 215 200 180 165 160 135 120 100

➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.


V CSA Certification Only.

1030 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Hub Size
Lamp Type Light Level (Inches) Catalog Numbers ➊
Pendant ­— One Hub, Rigid Mounting

3/4 MLEDA172P5
LED 17
1 MLEDA173P5

Pendant Cone ­— One Hub, Rigid Mounting

Lighting
3/4 MLEDD172P5
LED 17
1 MLEDD173P5

Lighting: Enclosed and Gasketed — Area — LED/Induction


Ceiling —
­ Five Hubs, Four Close-up Plugs

3/4 MLEDC172P5
LED 17
1 MLEDC173P5

 Suffix Voltage AC Frequency


BU 120 - 277 50/60 Hz
BH 347 - 480 50/60 Hz

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1031


© September 2010
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Hub Size
Lamp Type Light Level (Inches) Catalog Numbers ➊
Wall —
­ Five Hubs, Four Close-Up Plugs

3/4 MLEDW172P5
LED 17
1 MLEDW173P5

25° Stanchion —
­ One Hub
Lighting

1-1/4 MLEDS174P5
LED 17
1-1/2 MLEDS175P5
Lighting: Enclosed and Gasketed — Area — LED/Induction

90° Stanchion —
­ One Hub

1-1/4 MLEDR174P5
LED 17
1-1/2 MLEDR175P5

 Suffix Voltage AC Frequency


BU 120 - 277 50/60 Hz
BH 347 - 480 50/60 Hz

1032 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ LED Luminaire Mounting Hoods and Ballast Bodies
cETLus Certification. Enclosed and Gasketed

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Mounting Hoods

Description Hub Size (Inches) Catalog Number


Pendant
3/4 KPA-75
One Hub, Rigid Mounting
1 KPA-100

Pendant Cone
3/4 KPCH-75
One Hub, Rigid Mounting
1 KPCH-100

Ceiling

Lighting
3/4 KPC-75
Five Hubs, Four Close-Up Plugs
1 KPC-100

Wall
3/4 KPWB-75
Five Hubs, Four Close-Up Plugs
1 KPWB-100

Lighting: Enclosed and Gasketed — Area — LED/Induction


25° Stanchion
1-1/4 KPS-125
One Hub
1-1/2 KPS-150

90° Stanchion
1-1/4 KPST-125
One Hub
1-1/2 KPST-150

Replacement Globe Gaskets – Silicone Rubber

Description Catalog Number


Refractor Gasket KRF-GK

Fixture Unit — Electrical Specification

Catalog Number Voltage


Current Draw Fuse Kit ➊ Fixture Unit Voltage Range Suffix

120 Vac @ .77 Amps


F3 MLED17P5 120-277 Vac, 50/60 Hz BU
277 Vac @ .35 Amps

347 Vac @ .32 Amps


F3 MLED17P5 347-480 Vac, 50/60 Hz BH
480 Vac @ .23 Amps

➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.


V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1033


© September 2010
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For Use in Class I, Division 2, Groups A, B, C, D Locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED.

Class I, Division 2, Groups A, B, C, D


NEMA 4X

Applications Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn • Encapsulated with epoxy sealing compound
lighting control in Class I, Division 2 locations. • FS: aluminum
• Typical applications include walkways, security areas and any
other outdoor lighting application.
Certifications and Compliances
• For use with Mercmaster III – Low Profile, Mercmaster III, and • UL Standard: 1604 ­– Hazardous (Classified) Locations
Mercmaster III – 400 Series Luminaires. • cULus Recognized
• For remote mounting in FS Boxes.
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
Lighting

• Minimum time delay: 15 seconds to eliminate nuisance tripping.


• Provided with (3) 18AWG stranded leads 6”/152.4 mm in
length.
• Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol
Lighting: Enclosed and Gasketed — Area — LED/Induction

Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1. Dimensions


Voltage Range Suffix Designation
120 V, 50/60 Hz H1
208 V, 50/60 Hz H2
240 V, 50/60 Hz H3
277 V, 50/60 Hz H4
Mercmaster III wall mounting hood
with photocontrol installed shown
1.13”
28.7 mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box


Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range Catalog Number


120V, 50/60 Hz FSKA-PC120D2
1.375”
34.9 mm
208-277V, 50/60 Hz FSKA-PC247D2 1.375”
34.9 mm

2.56”
65.0 mm
2.56”
1.13” 65.0 mm
28.7 mm

Photocontrol for Field Installation


Voltage Range Max. Current Catalog Number
120 V, 50/60 Hz 8.3 Amp PC120D2
1.375”
208-277 V, 50/60 Hz 3.5 Amp PC247D2
34.9 mm 0.69”
17.5 mm

1.19”
2.56” 30.2 mm
65.0 mm 1.94”
49.2 mm

1034 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ LED Luminaire Dimensions
16.93”/
430.0 mm
15.27”/

cETLus Certification. Enclosed and Gasketed


387.9 mm

18.63”/473.2 mm 9.25”/
77.6 mm 235.0 mm
5.59”/
142.0 mm

11.96”/
303.8 mm

25°
15.40”/
391.16 mm
Dia.

15.40”/391.16 mm Dia. Dimensions in Inches/Millimeters 16.93”/ 15.40”/391.16 mm Dia.


430.0 mm
ANGLE STANCHION MOUNT PENDANT CONE MOUNT
WALL MOUNT 15.27”/
387.9 mm
16.93”/
430.0 18.87”/479.3
mm mm
18.63”/473.2 mm 9.25”/ 15.27”/ 17.22”/437.4 mm
10.93”/277.6 mm 235.0 mm 387.9 mm 5.59”/
Depends on 9.79”/248.7 mm
142.0 mm
18.63”/473.2 mm Length of
Conduit Used 9.25”/
4.06”/ 10.93”/277.6 mm 235.0 mm
5.59”/
103.1 mm
11.96”/ 142.0 mm
303.8 mm
9.40”/ 4.06”/
8.43”/ 7.56”/
238.8 mm 103.1 mm mm
214.1 192.0 mm25° 11.96”/
15.40”/
391.16 mm 303.8 mm
9.40”/ Dia.
238.8 mm 25°
15.40”/
391.16 mm
15.40”/391.16 mm Dia.
Dia.
15.40”/391.16 mm Dia. 15.40”/391.16 mmmm
15.40”/391.16 Dia.Dia. 15.40”/391.16 mm Dia.

CEILING MOUNT PENDANT MOUNT STANCHION MOUNT


ANGLE STANCHION MOUNT PENDANT CONE MOUNT
WALL MOUNT
Pendant Mount Pendant Cone Mount

Lighting
15.40”/391.16 mm Dia. 15.40”/391.16 mm Dia.
18.87”/479.3 mm
ANGLE STANCHION MOUNT PENDANT CONE MOUNT
WALL MOUNT 17.22”/437.4 mm 16.93”/
430.0 mm
Depends on 9.79”/248.7 18.87”/479.3
mm mm
Length of 15.27”/
Conduit Used 387.9 mm
17.22”/437.4 mm
Depends on 9.79”/248.7 mm
18.63”/473.2 mm 9.25”/
Length of
10.93”/277.6 mm 235.0 mm
Conduit Used
8.43”/ 7.56”/
214.1 mm 192.0 mm
4.06”/

Lighting: Enclosed and Gasketed — Area — LED/Induction


16.93”/
8.43”/ 103.1 mm
430.0 mm 7.56”/
214.1 mm 192.0 mm
15.27”/
387.9 mm 9.40”/
238.8 mm 15.40”/391.16 mm Dia. 25°
15.40”/391.16 mm Dia. 15.40”/391.16 mm Dia.
18.63”/473.2 mm 9.25”/
10.93”/277.6 mm CEILING MOUNT 235.0 mm PENDANT MOUNT STANCHION MOUNT
5.59”/
142.0 mm 15.40”/391.16 mm Dia.
15.40”/391.16 mm Dia. 15.40”/391.16 mm Dia.

4.06”/ CEILING MOUNT PENDANT MOUNT STANCHION MOUNT


103.1 mm 15.40”/391.16 mm Dia.
11.96”/
303.8 mm ANGLE
WALL MOUNT
9.40”/
238.8 mm
Ceiling Mount Wall Mount
25°
15.40”/
391.16 mm
Dia.

15.40”/391.16 mm Dia. 15.40”/391.16 mm Dia.

ANGLE STANCHION MOUNT PENDANT CONE MOUNT


WALL MOUNT
8.43”/
16.93”/ 214.1 mm
18.87”/479.3 mm
430.0 mm
15.27”/ 17.22”/437.4 mm
387.9 mm
Depends on 9.79”/248.7 mm
Length of
18.63”/473.2 mm 9.25”/ Conduit Used
10.93”/277.6 mm 235.0 mm
5.59”/ 15.40”/391.16 mm Dia. 15.40”/3
142.0 mm
CEILING MOUNT PEND
8.43”/ 7.56”/
214.1 mm 192.0 mm
11.96”/
303.8 mm

25°
15.40”/
391.16 mm
15.40”/391.16 mm Dia.
15.40”/391.16 mm Dia. Dia. 15.40”/391.16 mm Dia.

CEILING MOUNT PENDANT MOUNT STANCHION MOUNT

15.40”/391.16 mm Dia. 15.40”/391.16 mm Dia.

WALL MOUNT 25° ANGLE


Stanchion Mount
STANCHION MOUNT PENDANT CONE MOUNT
90° Stanchion Mount
18.87”/479.3 mm

17.22”/437.4 mm
Depends on 9.79”/248.7 mm
Length of
Conduit Used

8.43”/ 7.56”/
214.1 mm 192.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1035


© September 2010
15.40”/391.16 mm Dia. 15.40”/391.16 mm Dia.
15.40”/391.16 mm Dia.

CEILING MOUNT PENDANT MOUNT STANCHION MOUNT


Mercmaster™ LED Luminaire Weights and Photometric Data
cETLus Certification. Enclosed and Gasketed

Mercmaster LED Ballast and Accessory Weights


Description Weight in Lbs/Kg
Fixture Unit 22.00/10.0
Pendant 2.25/1.0
Pendant Cone 2.50/1.1
Ceiling 3.00/1.4
Wall 4.00/1.8
25° Stanchion 3.25/1.5
90° Stanchion 3.75/1.7

Photometric Data
Lighting

5 Degree Lumens CIE Type – Direct


0-5 68 REPORT NUMBER: MLED17P
5-10 201 Lamps: MercMaster LED, Class 1, Div 2, Polycarbonate Optic
10-15 326
15-20 445 Coefficients of Utilization – Zonal Cavity Method
20-25 546 Effective Floor Cavity Reflectance 0.20
Lighting: Enclosed and Gasketed — Area — LED/Induction

25-30 624 % CeilingRcc 80 70 50 30 10 0


30-35 652 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
35-40 646 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
40-45 610 1 111 108 104 102 109 106 103 100 101 99 97 98 96 94 94 93 91 89
45-50 556 2 103 97 91 87 101 95 90 86 91 87 84 88 85 82 85 83 80 78
50-55 473 3 96 87 80 75 93 85 79 74 83 77 73 80 75 72 77 74 70 69
55-60 355 4 88 78 71 65 86 77 70 65 75 69 64 72 67 63 70 66 62 60
60-65 213 5 82 71 63 57 80 70 62 57 68 61 56 66 60 56 64 59 55 53
65-70 96 Zonal Lumen Summary 6 76 64 56 51 74 64 56 51 62 55 50 60 54 50 59 53 49 48
70-75 25 Zone Lumens % Fixture 7 71 59 51 45 69 58 51 45 57 50 45 55 49 45 54 49 44 43
75-80 7 0-30 2212 37.8 8 66 54 46 41 65 53 46 41 52 45 41 51 45 40 50 44 40 38
80-85 5 0-40 3509 59.9 9 62 50 42 37 61 49 42 37 48 42 37 47 41 37 46 41 37 35
85-90 3 0-60 5503 94.0 10 58 46 39 34 57 46 39 34 45 38 34 44 38 34 43 37 33 32
90-95 1 0-90 5851 99.9
95-100 1 90-120 3 0.1
100-105 0 90-130 5 0.1
105-110 0 90-150 5 0.1
110-115 1 90-180 5 0.1
115-120 1 0-180 5856 100.0
120-125 1
125-130 1
130-135 0
135-140 0
140-145 0
145-150 0
150-155 0
155-160 0
160-165 0
165-170 0
170-175 0
175-180 0

1036 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Applications
• Areas where access for relamping is difficult, reliability is
essential and the environment is costly to maintain.
• Cold environment applications.
• Enclosed and gasketed fixtures suitable for use in marine
and wet locations, and in a wide range of industrial, chemical
processing and other areas where flammable gases and vapors
or combustible dusts are present under conditions defined by
NEC Class I, Division 2.
• Fixtures are also well suited for use in non-hazardous areas
where severe weather conditions, excessive moisture, dirt,
dust and corrosive atmospheres are a problem.
• Typical applications include pulp and paper mills, processing
plants, chemical plants, oil refineries, foundries, manufacturing
plants, storage areas and marine applications. Fixtures have
NEMA 4X listing.

Lighting
Features
• Instant start and restrike.
• High lumen output and efficacy (up to 73 lumens per Watt). 165 Watt Ceiling Mount Fixture with
• Fixtures operate safely in a 104 °F/40 °C ambient. Prismatic Glass Globe
• Good lumen maintenance provides less than 30% depreciation
after 60K hours of operation.
• Virtually maintenance free.
• Ultra long 100,000 hours of life keeps maintenance costs to

Lighting: Enclosed and Gasketed — Area — LED/Induction


a minimum.
• Starts in temperatures as low as -40 °F/-40 °C. Standard Materials
• Low total harmonic distortion (less than 10%). • Mounting hoods, ballast bodies and guards: cast copperfree
• No cycling at end of life. (4/10 of 1% max.) aluminum
• Modular design allows scores of fixture component • Exposed hardware: stainless steel; latch assemblies have
combinations to meet installation and lighting needs. stainless steel bolt and captive nut; reflectors and guards attach
• Mounting hoods include cone-shaped pendant, standard with stainless steel screws threading into stainless steel inserts
pendant, flexible pendant, ceiling and wall (tapped for 3/4” or 1” • Reflectors: fiberglass reinforced white polyester
NPT), 25° angle stanchion and straight stanchion (both tapped • Globes: heat-resistant prismatic glass
for 1-1/4” or 1-1/2” NPT).
• Cone hood fixtures for pendant mounting shed dust, dirt and Standard Finishes
combustible fibers, and inhibit build-up that “insulates” fixture • Mounting hoods, ballast bodies, guards: epoxy powder
and slows heat transfer. Also provide increased surface area for coat finish, electrostatically applied for complete, uniform
more effective heat dissipation. surface protection
• Reflector choice includes standard dome and 30º angle types, • Reflectors: white polyester finish
both made of fiberglass reinforced white polyester. Highly
resistant to unusually corrosive applications. Reflectors are Options
vented for cooler, dirt-free operation and maintained lumen • Fuses can be field-installed on Mercmaster III fixtures. Kits
output. They secure to ballast housing with stainless steel include fuse block, wire connectors and screws for attaching
screws threading into stainless steel inserts. to mounting hood. Fixtures with fuses do not comply with
• For high corrosion resistance, fixture housing, mounting hoods Marine Type Electric Fixtures Outside Type (Salt Water)
and guards are copperfree (4/10 of 1% max.) cast aluminum requirements for marine listing.
with baked epoxy finish, electrostatically applied for uniformity. • Photocell optional for all fixtures except cone and ceiling
All exposed hardware is stainless steel. mounts; provides automatic “on-off” control.
• Hinge has high lip for added safety during installation Certifications and Compliances
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for • UL Standard: UL 1598, UL 844, UL 1598A
positive sealing. Swing-away design of captive bolt and • CSA Standard: C22.2 No. 250, C22.2 No. 137
nut simplifies servicing. • cCSAus Certified
• Body gaskets and globe gaskets are high-temperature
silicone rubber.
• All Mercmaster III mounting hoods have provision for easy
field installation of fuses in fixtures (see fuse kit listings in this
catalog section).
• For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1037


© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Illustrated Features

Rugged, Vented Reflectors


Reflectors are thick, tough fiberglass
reinforced white polyester, vented for
cooler operation. Quickly attach with Mounting Hood and Globe Gaskets
Aluminum Inner Reflector stainless steel screws provided. Silicone rubber gaskets seals out
moisture, dirt and dust. Stays flexible,
Lighting

Solid aluminum inner reflector improves


photometric efficiency. Threaded Stainless Steel Inserts for withstands high temperatures. Closure
Screws design assures uniform gasket
Epoxy Finish Fixture bodies have stainless steel compression.
Ballast housing, hoods and guards are threaded inserts to receive stainless steel
copperfree aluminum with epoxy powder screws for reflector and guard. Prevents
coat finish. “freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Lighting: Enclosed and Gasketed — Area — LED/Induction

Prismatic Glass Globes, Refractors


and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflectors thread into ballast
housing and seal against a high- Cooler Operating Cone Hood
temperature silicone rubber gasket. Sloped surface sheds insulating dust,
dirt, and combustible fibers. Provides
cleaner, larger surface area for better heat
dissipation.

Photocell
Fuses Mount to Hood Bosses Available for all fixtures except cone and
Two screws secure fuse kit to mounting ceiling mount. Installs through knock-out
boss in any Mercmaster mounting hood. in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.

Electrical Protection “Safety” High


Ground wire provided to bond mounting Hinge
hood to ballast housing. Extra-high hinge
provides additional
protection against
Stainless Steel accidental
Latch Assembly ballast housing
Captive, stainless disengagement
steel latch assembly during installation
bolt and nut closes or maintenance.
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

1038 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

“T” Numbers for Mercmaster III Induction Fixtures ­— Class I, Division 2 and Class II, Division 1 and 2
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G
NEC/CEC V Temp. NEC/CEC V Temp.
Supply Indent. Number Nameplate Marking Indent. Number Nameplate Marking
Wire Ambient
Lamp Lamp Temp. Temp. Input with Globe or with with Enclosed with Globe or with with Enclosed
Watts Type (°F/°C) (°F/°C) Voltage Globe and Reflector Refractor Reflector Globe and Reflector Refractor Reflector
55 Induction 194/90 104/40 100-120 T3A ­— — T6 ­— —
55 Induction 194/90 104/40 200-277 T3B — — T6 — —
85 Induction 194/90 104/40 100-120 T3A — — T6 — —
85 Induction 194/90 104/40 200-277 T3A — — T6 — —
165 Induction 194/90 104/40 100-120 T3 T3 T3 T5 T5 T5
165 Induction 194/90 104/40 200-277 T3 T3 T3 T5 T5 T5

Lighting
“T” Numbers for Mercmaster III Induction Fixtures —
­ Class I, Zone 2
Class I, Zone 2 Class I, Zone 2
AEx nA nR IIC / Ex nA nR IIC AEx nR IIC / Ex nR IIC
Supply

Lighting: Enclosed and Gasketed — Area — LED/Induction


Wire Ambient with
Lamp Lamp Temp. Temp. Input Globe and with Globe with Reflector
Watts Type (°F/°C) (°F/°C) Voltage with Globe Reflector with Globe and Reflector Refractor with Lens
55 Induction 194/90 104/40 100-120 T4 T4 — — ­— —
55 Induction 194/90 104/40 200-277 T4 T4 — — — —
85 Induction 194/90 104/40 100-120 T4 T4 — — — —
85 Induction 194/90 104/40 200-277 T4 T4 — — — —
165 Induction 194/90 104/40 100-120 — — T5 T5 — T5
165 Induction 194/90 104/40 200-277 — — T5 T5 — T5

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101-
Range 86-100 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120
(°C)

V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1039


© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W ➎➏ 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Type Lamp Hub Size Catalog Numbers ➊➋➌


Mounting Watts (Inches) with Globe
Pendant

3/4 MLAQ552G3N
55 ➎➏
1 MLAQ553G3N

One Hub 3/4 MLAQ852G4N


85 ➎➏
Rigid Mounting ➍ 1 MLAQ853G4N

3/4 KPAQ1652G4N
Shown with 55 Watt Globe 165
1 KPAQ1653G4N

Pendant Cone Hood


Lighting

3/4 MLDQ552G3N
55 ➎➏
1 MLDQ553G3N

One Hub 3/4 MLDQ852G4N


85 ➎➏
Rigid Mounting 1 MLDQ853G4N
Lighting: Enclosed and Gasketed — Area — LED/Induction

3/4 KPDQ1652G4N
165
Shown with 55 Watt Globe 1 KPDQ1653G4N

Ceiling

3/4 MLCQ552G3N
55 ➎➏
1 MLCQ553G3N

Five Hubs 3/4 MLCQ852G4N


85 ➎➏
Four Close-Up Plugs 1 MLCQ853G4N

3/4 KPCQ1652G4N
165
Shown with 55 Watt Refractor 1 KPCQ1653G4N

➊ Add voltage suffix -A1 for 120 Vac: 90-140 Vac; -A6 for 277: 180-305 Vac.
➋ See following pages for accessory ordering information.
➌ For fixtures with guard, substitute G for N before adding suffix.
➍ For flexible pendant mount, change A to F in catalog number.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR).
➏ Add Z suffix for factory sealed non-sparking/restricted breathing protection (Ex nA nR) V.
V CSA Certification Only.

1040 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W ➎➏ 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Type Lamp Hub Size Catalog Numbers ➊➋➌


Mounting Watts (Inches) with Globe
Wall

3/4 MLWQ552G3N
55 ➎➏
1 MLWQ553G3N

Five Hubs 3/4 MLWQ852G4N


85 ➎➏
Four Close-Up Plugs 1 MLWQ853G4N

3/4 KPWQ1652G4N
165
Shown with 85 Watt Globe 1 KPWQ1653G4N

25° Stanchion

Lighting
1-1/4 MLSQ554G3N
55 ➎➏
1-1/2 MLSQ555G3N

1-1/4 MLSQ854G4N
One Hub 85 ➎➏
1-1/2 MLSQ855G4N

Lighting: Enclosed and Gasketed — Area — LED/Induction


1-1/4 KPSQ1654G4N
Shown with 55 Watt Globe 165
1-1/2 KPSQ1655G4N

Straight Stanchion

1-1/4 MLRQ554G3N
55 ➎➏
1-1/2 MLRQ555G3N

1-1/4 MLRQ854G4N
One Hub 85 ➎➏
1-1/2 MLRQ855G4N

1-1/4 KPRQ1654G4N
Shown with 55 Watt Globe 165
1-1/2 KPRQ1655G4N

➊ Add voltage suffix -A1 for 120 Vac: 90-140 Vac; -A6 for 277: 180-305 Vac.
➋ See following pages for accessory ordering information.
➌ For fixtures with guard, substitute G for N before adding suffix.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR).
➏ Add Z suffix for factory sealed non-sparking/restricted breathing protection (Ex nA nR). V
V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1041


© September 2010
Mercmaster™ III Induction Luminaire Mounting Hoods
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Hub Size
Description (Inches) Catalog Number
Pendant
One Hub, 3/4 KPA-75
Rigid Mounting 1 KPA-100

Pendant — Flexible
One Hub, 3/4 KPAF-75
Flexible Mounting 1 KPAF-100
Lighting

Pendant Cone
Cone Hood 3/4 KPCH-75
Rigid Mounting 1 KPCH-100
Lighting: Enclosed and Gasketed — Area — LED/Induction

Ceiling
Five Hubs, 3/4 KPC-75
Four Close-Up Plugs 1 KPC-100

Wall
Five Hubs, 3/4 KPWB-75
Four Close-Up Plugs 1 KPWB-100

25° Stanchion
One Hub 1-1/4 KPS-125
1-1/2 KPS-150

90° Stanchion
One Hub 1-1/4 KPST-125
1-1/2 KPST-150

1042 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaire Fixture Units
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Fixture Units — Less Mounting Hoods

Fixture Unit Add Voltage Suffixes


Type
Frequency Lamp Watts Catalog Number 120 V 277 V
Globe

Induction 50/60 Hz 55 MLBRG355Q -A1 -A6

Globe

Lighting
Induction 50/60 Hz 85 MLBRG485Q -A1 -A6

Globe

Lighting: Enclosed and Gasketed — Area — LED/Induction


Induction 50/60 Hz 165 KPB165QG4 -A1 -A6

Enclosed Reflector/Lens

Induction 50/60 Hz 165 KPB165QRL -A1 -A6

Type 2 Refractor

Induction 50/60 Hz 165 KPB165QJ2 -A1 -A6

Type 5 Refractor
Induction 50/60 Hz 165 KPB165QJ5 -A1 -A6

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1043


© September 2010
Mercmaster™ III Induction Luminaire Accessories and Replacement Parts
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Item Description Watts Catalog Number


White Polyester Reflectors
Standard Dome 55 W, 85 W, 165 W CMR-4ST ➊
Deep Dome (Dark Skies Compliant) 55 W, 85 W, 165 W CMR-4DD ➊

30º Angle 55 W, 85 W, 165 W CMR-4AN ➊

Prismatic Glass Globes – Heat-Resistant


Clear 55 W VPGL-3HR
Lighting

Clear 85 W, 165 W VPGL-4HR

Refractor/Reflector Assemblies
Closed Glass Refractor NEMA Type II 165 W KPRF4002
Lighting: Enclosed and Gasketed — Area — LED/Induction

Heat- and impact-resistant glass lens.


Closed Glass Refractor NEMA Type V 165 W KPRF4005

Enclosed Reflector/Lens 165 W KPR-4HB

Guards
55 W KRG2

85 W, 165 W KPGU400

Mercmaster III Fixture Unit, Component and Accessory Weights ➋


Fixture Unit and Mounting Hoods Wt. lbs/kg Reflectors Wt. lbs/kg Refractors, Globes & Guard Wt. lbs/kg
55W and 85W Fixture 28.00/12.7 Standard Dome 2.50/1.1 Glass Globe 3.75/1.7
165W Fixture 33.00/15.0 30º Angle 2.50/1.1 Globe Guard 1.00/0.5
Pendant 2.25/1.0 Deep Dome 3.50/1.6
Pendant Cone 2.50/1.1
Ceiling 3.00/1.4
Wall 4.00/1.8
25º Stanchion 3.25/1.5
90º Stanchion 3.33/1.5

➊ Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
➋ Weights are approximate.

1044 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaire Technical Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

55W, 85W, 165W 55W, 85W 165W


Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Class I, Zone 2
Class II, Division 1 and 2, Groups E, F, G AEx nA nR, IIC AEx nR, IIC
NEMA 4X Ex nA nR IIC Ex nR IIC

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily to hood with one screw. ➊
Lamp Watts Volts Fuse Qty. Req. Fuse Catalog Number
120/277 1 F2
55, 85, 165
208-240 2 F2

Electromagnetic Compatibility
A.) Complies with European norms EN55015, EN6100-3-2 and EN61547
B.) RFI
a.) Meets standard EN55022 and is valid for frequencies up to 1000 MHz.

Electrical Characteristics
55 W 55 W 85 W 85 W 165 W 165 W
100-120 V 200-277 V 100-120 V 200-277 V 100-120 V 200-277 V
System power ➋ nom. W 55 55 85 85 165 165

Lighting
System power ➋ min. W 53.1 53.1 82 82 160 160
System power ➋ max. W 56.9 56.9 88 88 190 190
AC supply voltage nom. V 120 230 120 230 120 230
AC supply voltage min. V 90 180 90 180 90 180
AC supply voltage max. V 140 305 140 305 140 305
DC supply voltage nom. V 120 230 120 230 120 230
DC supply voltage min. V 90 180 90 180 90 180

Lighting: Enclosed and Gasketed — Area — LED/Induction


DC supply voltage max. V 180 350 180 350 180 350
Supply frequency nom. Hz 60 50 60 50 60 50
Supply frequency min. Hz 47 47 47 47 47 47
Supply frequency max. Hz 63 63 63 63 63 63
Supply current nom. mA 460 260 730 400 1420 740
Inrush current max. A 16 12 16 12 28 24
Duration inrush current max. usec 170 170 170 170 150 140
Power factor nom. >0.92 >0.92 >0.92 >0.92 >0.92 >0.92
HF output frequency nom. MHz 2.65 2.65 2.65 2.65 2.65 2.65
HF output frequency min. MHz 2.3 2.3 2.3 2.3 2.3 2.3
HF output frequency max. MHz 3 3 3 3 3.0 3.0
HF output voltage max. kV 1.5 1.5 1.5 1.5 1.5 1.5
Leakage current mA <0.5 <0.5 <0.5 <0.5 <0.5 <0.5
Overvoltage 200Vac 400Vac 200Vac 400Vac 200Vac 400Vac

Lamp Characteristics
Values at 100 Hrs. QL 55 W QL 85 W QL 165 W
Luminous flux nom. lm 3,500 6,000 12,000
Luminous flux min. lm 3,200 5,500 11,000
Luminous flux max. lm 3,800 6,500 12,500
System efficacy nom. lm/W 63.5 70 72.5

Lamp Operation
A.) Ignition and Lifetime Performance
a.) Ignition time <0.5 seconds
Hot Restrike time <0.5 seconds
b.) Induction lighting offers a direct, flicker-free ignition after switch-on, in both cold and hot conditions
B.) Lumen Maintenance
a.)The lumens of an induction lamp are expected to have depreciated after 60,000 hours to no less than 75% of the initial lumens

➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.


➋ At design voltage.
V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1045


© September 2010
Mercmaster™ III Induction Luminaire Dimensions
Enclosed and Gasketed. For Hazardous and Adverse Locations

13.44"/
341.4 mm

11.82"/
300.2 mm

10.38"/
10.25"/ 263.7 mm
260.4 mm
11.44"/
10.77"/ 290.6 mm
273.6 mm
Lighting

16.38"/
12.25"/ 416.1 mm Dia.
311.2 mm Dia.
16.63"/
14.25"/ 422.4 mm Dia.
362.0 mm Dia.

165 Watt Pendant with Globe, 165 Watt Ceiling Mount


Guard and Reflectors with Refractor, Enclosed Reflector and Guards
Lighting: Enclosed and Gasketed — Area — LED/Induction

107.7 mm
107.7 mm

4.24”/
4.24"/

267.2 mm
267.2 mm

287.5 mm
10.52”/
10.52"/

11.32"/

314.2 mm

376.2 mm
12.37"/
376.2 mm

399.3 mm
385.3 mm

14.81"/
14.81"/

15.72"/
15.17"/

85 Watt 55 Watt

1046 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaire Dimensions
Enclosed and Gasketed. For Hazardous and Adverse Locations

Pendant (Rigid or Flex) Pendant Cone Ceiling


12.06"/ 13.62"/
306.3 mm 12.06"/ 346.9 mm
306.3 mm
12.06"/
1.17"/ 306.3 mm
29.7 mm
5.59"/
142.0 mm

1.75"/
44.5 mm

25° Stanchion 90° Stanchion Wall Mount

Lighting
17.23”/ 17.00"/
437.6 mm 431.8 mm
/
27” 0”/ 9.79”/ 10.93”/
15. .9 mm 2.0 mm
8 248.7 mm 277.6 mm
7 .
38 50
5”/
9.2 0 mm
5 . ”/
23 .03 m
12 .6 m
5 12.03”/
30 12.03”/

Lighting: Enclosed and Gasketed — Area — LED/Induction


SET SCREW 305.6 mm 305.6 mm
3.36"/
t
Se w 85.3 mm
re 1.57"/
Sc 9”/ 39.9 mm
7.5 8 mm
2 .
19
25°
4.06"/
103.1 mm
2.03"/
51.6 mm

Standard Polyester Reflector 30º Angle Polyester Reflector Deep Dome

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1047


© September 2010
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For Use in Class I, Division 2, Groups A, B, C, D Locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED.

Class I, Division 2, Groups A, B, C, D


NEMA 4X

Applications Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn • Encapsulated with epoxy sealing compound
lighting control in Class I, Division 2 locations. • FS: aluminum
• Typical applications include walkways, security areas and any
other outdoor lighting application.
Certifications and Compliances
• For use with Mercmaster III – Low Profile, Mercmaster III, and • UL Standard: 1604 ­– Hazardous (Classified) Locations
Mercmaster III – 400 Series Luminaires. • cULus Recognized
• For remote mounting in FS Boxes.
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
Lighting

• Minimum time delay: 15 seconds to eliminate nuisiance tripping.


• Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
• Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol
Lighting: Enclosed and Gasketed — Area — LED/Induction

Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1. Dimensions


Voltage Range Suffix Designation
120 V, 50/60 Hz H1
208 V, 50/60 Hz H2
240 V, 50/60 Hz H3
277 V, 50/60 Hz H4
Mercmaster III wall mounting hood
with photocontrol installed shown
1.13”
28.7 mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box


Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range Catalog Number


120V, 50/60 Hz FSKA-PC120D2
1.375”
34.9 mm
208-277V, 50/60 Hz FSKA-PC247D2 1.375”
34.9 mm

2.56”
65.0 mm
2.56”
1.13” 65.0 mm
28.7 mm

Photocontrol for Field Installation


Voltage Range Max. Current Catalog Number
120 V, 50/60 Hz 8.3 Amp PC120D2
1.375”
208-277 V, 50/60 Hz 3.5 Amp PC247D2
34.9 mm 0.69”
17.5 mm

1.19”
2.56” 30.2 mm
65.0 mm 1.94”
49.2 mm

1048 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaire 55 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 78%


CIE Type – General Diffuse REPORT NUMBER: MLBR55QL
Lamps: 55 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 50 50 50 46
0-10 20.62 1 73 68 64 59 68 63 59 55 54 51 48 45 43 40 37 35 34 30
10-20 57.15 2 65 57 51 45 60 53 47 42 45 40 36 37 34 31 31 28 25 22
20-30 95.87 3 59 49 42 36 54 45 39 33 38 33 29 32 28 24 26 23 20 17
30-40 145.23 4 53 43 35 29 49 39 33 27 33 28 23 28 23 20 22 19 16 13
40-50 191.57 5 48 38 30 24 44 35 28 23 29 24 20 24 20 16 20 16 13 11
50-60 232.82 6 44 33 26 21 41 31 24 19 26 21 17 22 17 14 18 14 11 9

Lighting
60-70 266.04 7 41 30 23 18 38 28 21 17 24 18 14 20 15 12 16 12 10 8
70-80 288.86 8 38 27 20 15 35 25 19 14 21 16 12 18 14 10 15 11 9 7
80-90 299.24 9 35 24 18 14 32 23 17 13 19 14 11 16 12 9 13 10 8 6
90-100 299.72 10 33 22 16 12 30 21 15 11 18 13 10 15 11 8 12 9 7 5
100-110 288.18
110-120 254.71 Zonal Lumen Summary
120-130 184.93 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

Lighting: Enclosed and Gasketed — Area — LED/Induction


130-140 87.45 0-30 173.63 5.0 6.4 90-120 842.61 24.1 30.9
140-150 16.45 0-40 318.76 9.1 11.7 90-130 1027.54 29.4 37.6
150-160 16.70 0-60 743.26 21.2 27.2 90-150 1131.69 32.3 37.6
160-170 0.05 0-90 1597.39 45.6 58.5 90-180 1132.40 32.4 41.5
170-180 0.00 0-180 2729.80 78.0 100.0

Total Luminaire Efficiency = 68.6%


CIE Type – Direct REPORT NUMBER: MLBR55QLST
Spacing Criteria: 1.40 Lamps: 55 W QL lamp with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 81 81 81 81 79 79 79 79 76 76 76 72 72 72 69 69 69 67
0-10 53.72 1 72 68 64 61 70 66 63 60 63 60 57 60 58 55 57 55 54 52
10-20 151.63 2 67 57 52 47 62 56 51 46 53 49 45 51 47 44 48 45 43 14
20-30 237.12 3 58 49 43 38 56 48 42 37 46 41 36 44 39 35 42 38 35 33
30-40 314.91 4 52 43 36 31 51 42 36 31 40 34 30 38 33 29 37 32 29 27
40-50 369.39 5 48 38 31 26 46 37 31 26 35 30 25 34 29 25 32 28 25 23
50-60 394.66 6 44 34 27 22 43 33 27 22 32 26 22 30 25 21 29 25 21 20
60-70 389.48 7 41 31 24 19 39 30 24 19 29 23 19 28 22 19 23 22 18 17
70-80 306.69 8 38 28 21 17 37 27 21 17 26 21 17 25 20 17 24 20 16 15
80-90 141.30 9 35 25 19 15 34 25 19 15 24 19 15 23 18 15 22 18 15 13
90-100 20.15 10 33 23 17 14 32 23 17 14 22 17 13 21 17 13 21 16 13 12
100-110 4.14
110-120 4.10 Zonal Lumen Summary
120-130 5.12 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 4.61 0-30 442.48 12.6 18.4 90-120 28.39 0.8 1.2
140-150 1.93 0-40 757.38 21.6 31.6 90-130 33.51 1.0 1.4
150-160 0.37 0-60 1521.42 43.5 63.4 90-150 40.05 1.1 1.4
160-170 0.11 0-90 2358.89 67.4 98.3 90-180 40.58 1.2 1.7
170-180 0.04 0-180 2399.47 68.6 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1049


© September 2010
Mercmaster™ III Induction Luminaire 55 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 61.1%


CIE Type – Direct REPORT NUMBER: MLBR55QLAN
Spacing Criteria: 1.80 Lamps: 55 W QL lamp with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 72 72 72 72 69 69 69 69 65 65 65 62 62 62 58 58 58 57
0-10 42.29 1 63 59 56 53 61 58 55 52 54 52 49 51 49 47 48 46 45 42
10-20 134.14 2 57 51 46 42 55 49 45 41 46 42 39 43 40 37 41 38 36 34
20-30 213.06 3 51 44 38 34 49 43 37 33 40 35 32 38 34 31 35 32 30 28
30-40 282.99 4 47 38 32 28 45 37 32 27 35 30 27 33 29 26 31 28 25 23
40-50 314.71 5 43 34 28 24 41 33 27 23 31 26 23 29 25 22 28 24 21 20
50-60 306.62 6 39 30 25 20 38 30 24 20 28 23 20 27 22 19 25 21 18 17
Lighting

60-70 275.85 7 36 27 22 18 35 27 21 18 25 21 17 24 20 17 23 19 16 15
70-80 232.10 8 34 25 19 16 32 24 19 15 23 18 15 22 18 15 21 17 14 13
80-90 171.94 9 31 23 18 14 30 22 17 14 21 17 13 20 16 13 19 16 13 12
90-100 100.63 10 29 21 16 13 28 20 16 12 20 15 12 19 15 12 18 14 12 10
100-110 40.56
110-120 9.45 Zonal Lumen Summary
120-130 3.75 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
Lighting: Enclosed and Gasketed — Area — LED/Induction

130-140 2.43 0-30 394.49 11.3 18.5 90-120 150.64 4.3 7.0
140-150 0.97 0-40 677.48 19.4 31.7 90-130 154.39 4.4 7.2
150-160 0.34 0-60 1298.80 37.1 60.8 90-150 157.79 4.5 7.2
160-170 0.25 0-90 1978.69 56.5 92.6 90-180 158.45 4.5 7.4
170-180 0.06 0-180 2137.14 61.1 100.0

Total Luminaire Efficiency = 59.2%


CIE Type – Direct REPORT NUMBER: MLBR55QLHB
Spacing Criteria: 1.58 Lamps: 55 W QL lamp with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 70 70 70 70 69 69 69 69 66 66 66 63 63 63 60 60 60 59
0-10 64.78 1 65 63 61 59 64 62 60 58 59 57 56 57 55 54 55 54 53 51
10-20 196.79 2 60 56 52 49 58 54 51 48 52 40 47 51 48 46 49 47 45 44
20-30 326.97 3 55 49 45 41 54 48 44 41 47 43 40 45 42 40 44 41 39 38
30-40 437.52 4 50 44 39 35 49 43 39 35 42 38 35 40 37 34 39 36 34 32
40-50 470.90 5 46 39 34 30 45 39 34 30 37 33 30 36 32 30 35 32 29 28
50-60 345.47 6 43 35 30 27 42 35 30 26 34 29 26 33 29 26 32 28 26 25
60-70 167.60 7 40 32 27 23 39 31 27 23 31 26 23 30 26 23 29 25 23 22
70-80 52.79 8 37 29 24 21 36 29 24 21 28 24 21 27 23 20 26 23 20 19
80-90 7.73 9 34 27 22 19 34 26 22 19 26 21 18 25 21 18 24 21 18 17
90-100 0.00 10 32 24 20 17 31 24 20 17 24 19 17 23 19 17 22 19 17 15
100-110 0.00
110-120 0.14 Zonal Lumen Summary
120-130 0.26 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.16 0-30 588.53 16.8 28.4 90-120 0.14 0.0 0.0
140-150 0.24 0-40 1026.05 29.3 49.5 90-130 0.41 0.0 0.0
150-160 0.00 0-60 1842.43 52.6 88.9 90-150 0.81 0.0 0.0
160-170 0.04 0-90 2070.54 59.2 100.0 90-180 0.87 0.0 0.0
170-180 0.02 0-180 2071.41 59.2 100.0

1050 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaire 85 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 78.4%


REPORT NUMBER: MLBR85QL
CIE Type – General Diffuse
Lamps: 85 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 86 86 86 86 80 80 80 80 69 69 69 59 59 59 50 50 50 46
0-10 35.55 1 74 69 64 60 68 64 59 56 54 51 48 46 43 41 38 36 34 30
10-20 98.53 2 66 58 51 46 60 53 47 42 45 41 36 38 34 31 31 28 25 22
20-30 165.29 3 59 49 42 36 54 46 39 34 39 33 29 32 28 24 26 23 20 17
30-40 250.39 4 53 43 35 29 49 40 33 27 34 28 24 28 23 20 23 19 16 13
40-50 330.30 5 49 38 30 25 45 35 28 23 30 24 20 25 20 17 20 16 13 11
50-60 401.42 6 45 34 26 21 41 31 24 19 26 21 17 22 17 14 18 14 11 9

Lighting
60-70 458.68 7 41 30 23 18 38 28 21 17 24 18 14 20 15 12 16 13 10 8
70-80 498.03 8 38 27 20 16 35 25 19 14 21 16 12 18 14 11 15 11 9 7
80-90 515.94 9 35 25 18 14 33 23 17 13 20 15 11 16 12 9 13 10 8 6
90-100 516.75 10 33 23 16 12 30 21 15 11 18 13 10 15 11 8 12 9 7 5
100-110 496.86
110-120 439.16 Zonal Lumen Summary
120-130 318.85 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

Lighting: Enclosed and Gasketed — Area — LED/Induction


130-140 150.78 0-30 299.37 5.0 6.4 90-120 1452.77 24.2 30.9
140-150 28.79 0-40 549.76 9.2 11.7 90-130 1771.62 29.5 37.6
150-160 1.15 0-60 1281.48 21.4 27.2 90-150 1951.19 32.5 37.6
160-170 0.08 0-90 2754.13 45.9 58.5 90-180 1952.42 32.5 41.5
170-180 0.00 0-180 4706.55 78.4 100.0

Total Luminaire Efficiency = 69%


CIE Type – Direct REPORT NUMBER: MLBR85QLST
Spacing Lamps: 85 W QL lamp with Standard Dome Reflector
Plane Criteria
0-180 1.40 Coefficients of Utilization - Zonal Cavity Method
90-270 1.40 Effective Floor Cavity Reflectance 0.20
Diagonal 1.58 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 82 82 82 82 80 80 80 80 76 76 76 72 72 72 69 69 69 68
0-10 92.63 1 73 68 65 61 70 67 63 60 63 60 58 60 58 56 58 56 54 52
10-20 261.43 2 65 58 52 47 63 56 51 47 54 49 45 51 47 44 49 46 43 41
20-30 408.83 3 58 50 43 38 56 48 42 37 46 41 37 44 39 36 42 38 35 33
30-40 542.94 4 53 43 36 31 51 42 36 31 40 35 30 38 34 30 37 33 29 27
40-50 636.87 5 48 38 31 26 47 37 31 26 36 30 25 34 29 25 33 28 25 23
50-60 680.44 6 44 34 27 22 43 33 27 22 32 26 22 31 25 22 29 25 21 20
60-70 671.51 7 41 31 24 19 40 30 24 19 29 23 19 28 23 19 27 22 19 17
70-80 528.78 8 38 28 21 17 37 27 21 17 26 21 17 25 20 17 24 20 16 15
80-90 243.62 9 35 25 19 15 34 25 19 15 24 19 15 23 18 15 22 18 15 13
90-100 34.74 10 33 23 18 14 32 23 17 14 22 17 13 21 17 13 21 16 13 12
100-110 7.14
110-120 7.07 Zonal Lumen Summary
120-130 8.83 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 7.95 0-30 762.89 12.7 18.4 90-120 48.95 0.8 1.2
140-150 3.33 0-40 1305.83 21.8 31.6 90-130 57.78 1.0 1.4
150-160 0.64 0-60 2623.14 43.7 63.4 90-150 69.06 1.2 1.4
160-170 0.19 0-90 4067.06 67.8 98.3 90-180 69.96 1.2 1.7
170-180 0.07 0-180 4137.02 69.0 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1051


© September 2010
Mercmaster™ III Induction Luminaire 85 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 61.4%


CIE Type – Direct REPORT NUMBER: MLBR85QLAN
Spacing Lamps: 85 W QL lamp with 30° Angle Dome Reflector
Plane Criteria
0-180 1.80 Coefficients of Utilization - Zonal Cavity Method
90-270 1.44 Effective Floor Cavity Reflectance 0.20
Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 72 72 72 72 70 70 70 70 66 66 66 62 62 62 58 58 58 57
0-10 81.53 1 64 60 56 53 61 58 55 52 54 52 50 51 49 47 48 46 45 43
10-20 231.27 2 57 51 46 42 55 49 45 41 46 43 39 44 40 38 41 38 36 34
20-30 367.34 3 52 44 38 34 49 43 37 33 40 36 32 38 34 31 36 32 30 28
30-40 487.91 4 47 39 33 28 45 38 32 28 35 31 27 33 29 26 31 28 25 23
40-50 542.61 5 43 34 28 24 41 33 28 23 31 26 23 30 25 22 28 24 21 20
Lighting

50-60 528.65 6 39 31 25 20 38 30 24 20 28 23 20 27 22 19 25 21 19 17
60-70 475.60 7 36 28 22 18 35 27 21 18 25 21 17 24 20 17 23 19 16 15
70-80 400.17 8 34 25 20 16 33 24 19 16 23 19 15 22 18 15 21 17 14 13
80-90 296.45 9 32 23 18 14 30 22 17 14 21 17 14 20 16 13 19 16 13 12
90-100 173.50 10 30 21 16 13 29 21 16 12 20 15 12 19 15 12 18 14 12 11
100-110 69.93
110-120 16.29 Zonal Lumen Summary
Lighting: Enclosed and Gasketed — Area — LED/Induction

120-130 6.47 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 4.19 0-30 680.15 11.3 18.5 90-120 259.73 4.3 7.0
140-150 1.67 0-40 1168.06 19.5 31.7 90-130 266.19 4.4 7.2
150-160 0.59 0-60 2239.32 37.3 60.8 90-150 272.06 4.5 7.2
160-170 0.44 0-90 3411.54 56.9 92.6 90-180 273.19 4.6 7.4
170-180 0.10 0-180 2684.73 61.4 100.0

Total Luminaire Efficiency = 59.5%


CIE Type – Direct REPORT NUMBER: MLBR85QLHB
Spacing Lamps: 85 W QL lamp with High Bay Reflector
Plane Criteria
0-180 1.58 Coefficients of Utilization - Zonal Cavity Method
90-270 1.58 Effective Floor Cavity Reflectance 0.20
Diagonal 1.58 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 71 71 71 71 69 69 69 69 66 66 66 63 63 63 61 61 61 59
0-10 111.69 1 66 63 61 59 64 62 60 58 59 58 56 57 56 55 55 54 53 52
10-20 339.29 2 60 56 52 49 59 55 51 49 53 50 48 51 49 46 49 47 45 44
20-30 563.74 3 55 50 45 42 54 49 44 41 47 43 40 45 42 40 44 41 39 38
30-40 754.34 4 51 44 39 35 49 43 39 35 42 38 35 40 37 34 39 36 34 33
40-50 811.90 5 47 39 34 31 45 39 34 30 38 33 30 36 33 30 35 32 29 28
50-60 595.64 6 43 35 30 27 42 35 30 27 34 30 26 33 29 26 32 29 26 25
60-70 288.96 7 40 32 27 24 39 32 27 23 31 26 23 30 26 23 29 26 23 22
70-80 91.02 8 37 29 24 21 36 29 24 21 28 24 21 27 23 21 27 23 20 19
80-90 13.32 9 35 27 22 19 34 26 22 19 26 22 19 25 21 18 24 21 18 17
90-100 0.00 10 32 25 20 17 32 24 20 17 24 20 17 23 19 17 23 19 17 16
100-110 0.00
110-120 0.25 Zonal Lumen Summary
120-130 0.46 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.28 0-30 1014.71 16.9 28.4 90-120 0.25 0.0 0.0
140-150 0.41 0-40 1769.06 29.5 49.5 90-130 0.70 0.0 0.0
150-160 0.00 0-60 3176.60 52.9 88.9 90-150 1.39 0.0 0.0
160-170 0.07 0-90 3569.90 59.5 100.0 90-180 1.50 0.0 0.0
170-180 0.04 0-180 3571.40 59.5 100.0

1052 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Induction Luminaire 165 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 70.7%


REPORT NUMBER: KPB165QLG
CIE Type – General Diffuse
Lamps: 165 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 77 77 77 77 72 72 72 72 62 62 62 53 53 53 45 45 45 41
0-10 57.43 1 66 62 57 54 61 57 53 50 49 46 43 41 38 36 33 32 30 26
10-20 158.04 2 59 52 46 41 54 48 42 38 40 36 33 34 30 27 27 25 22 19
20-30 282.31 3 53 44 38 32 49 41 35 30 34 30 26 28 25 22 23 20 18 15
30-40 435.46 4 48 38 32 26 44 36 29 24 30 25 21 25 21 17 20 17 14 11
40-50 580.50 5 44 34 27 22 40 31 25 20 26 21 17 22 18 15 17 14 12 9
50-60 715.54 6 40 30 23 19 37 28 22 17 23 18 15 19 15 12 16 12 10 8
60-70 829.63 7 37 27 20 16 34 25 19 15 21 16 13 17 14 11 14 11 8 7

Lighting
70-80 904.70 8 34 24 18 14 31 22 17 13 19 14 11 16 12 9 13 10 7 6
80-90 935.31 9 32 22 16 12 29 20 15 11 17 13 10 15 11 8 12 9 7 5
90-100 924.84 10 30 20 14 11 27 19 13 10 16 12 9 13 10 7 11 8 6 4
100-110 870.28
110-120 758.05 Zonal Lumen Summary
120-130 568.50 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 328.65 0-30 497.77 4.1 5.9 90-120 2553.16 21.3 30.1

Lighting: Enclosed and Gasketed — Area — LED/Induction


140-150 119.26 0-40 933.23 7.8 11.0 90-130 3121.65 26.0 36.8
150-160 15.42 0-60 2229.28 18.6 26.3 90-150 3569.56 29.7 36.8
160-170 0.71 0-90 4898.92 40.8 57.7 90-180 3585.75 29.9 42.3
170-180 0.05 0-180 8484.67 70.7 100.0

Total Luminaire Efficiency = 58.5%


CIE Type – Direct REPORT NUMBER: KPB165QLST
Spacing Lamps: 165 W QL lamp with Standard Dome Reflector
Plane Criteria
0-180 1.34 Coefficients of Utilization - Zonal Cavity Method
90-270 1.34 Effective Floor Cavity Reflectance 0.20
Diagonal 1.56 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 69 69 69 69 68 68 68 68 64 64 64 61 61 61 59 59 59 57
0-10 149.58 1 61 58 54 51 59 56 53 50 53 51 49 51 49 47 48 47 45 44
10-20 419.79 2 55 49 44 40 53 47 43 39 45 41 38 43 40 37 41 38 36 34
20-30 669.69 3 49 42 36 32 47 41 35 31 39 34 30 37 33 30 35 32 29 27
30-40 893.40 4 44 36 30 26 43 35 30 26 34 29 25 32 28 25 31 27 24 23
40-50 1052.06 5 41 32 26 22 39 31 26 21 30 25 21 28 24 21 27 23 20 19
50-60 1151.10 6 37 29 23 19 36 28 22 18 27 22 18 25 21 18 24 21 18 16
60-70 1157.87 7 34 26 20 16 33 25 20 16 24 19 16 23 19 16 22 18 15 14
70-80 920.80 8 32 23 18 14 31 23 18 14 22 17 14 21 17 14 20 16 14 12
80-90 462.02 9 30 21 16 13 29 21 16 12 20 16 12 19 15 12 19 15 12 11
90-100 95.45 10 28 20 15 11 27 19 14 11 18 14 11 18 14 11 17 14 11 10
100-110 12.02
110-120 10.92 Zonal Lumen Summary
120-130 11.39 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 11.34 0-30 1239.06 10.3 17.6 90-120 118.39 1.0 1.7
140-150 5.50 0-40 2132.46 17.8 30.4 90-130 129.78 1.1 1.8
150-160 1.16 0-60 4335.62 36.1 61.7 90-150 146.62 1.2 1.8
160-170 0.07 0-90 6876.32 57.3 97.9 90-180 147.97 1.2 2.1
170-180 0.12 0-180 7024.28 58.5 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1053


© September 2010
Mercmaster™ III Induction Luminaire 165 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 61.4%


CIE Type – Direct REPORT NUMBER: KPB165QLAN
Spacing Lamps: 165 W QL lamp with 30° Angle Dome Reflector
Plane Criteria
0-180 1.80 Coefficients of Utilization - Zonal Cavity Method
90-270 1.44 Effective Floor Cavity Reflectance 0.20
Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 72 72 72 72 70 70 70 70 66 66 66 62 62 62 58 58 58 57
0-10 163.07 1 64 60 56 53 61 58 55 52 54 52 50 51 49 47 48 46 45 43
10-20 462.54 2 57 51 46 42 55 49 45 41 46 43 39 44 40 38 41 38 36 34
20-30 734.69 3 52 44 38 34 49 43 37 33 40 36 32 38 34 31 36 32 30 28
30-40 975.82 4 47 39 33 28 45 38 32 28 35 31 27 33 29 26 31 28 25 23
40-50 1085.22 5 43 34 28 24 41 33 28 23 31 26 23 30 25 22 28 24 21 20
50-60 1057.29 6 39 31 25 20 38 30 24 20 28 23 20 27 22 19 25 21 19 17
Lighting

60-70 951.20 7 36 28 22 18 35 27 21 18 25 21 17 24 20 17 23 19 16 15
70-80 800.34 8 34 25 20 16 33 24 19 16 23 19 15 22 18 15 21 17 14 13
80-90 592.90 9 32 23 18 14 30 22 17 14 21 17 14 20 16 13 19 16 13 12
90-100 347.00 10 30 21 16 13 29 21 16 12 20 15 12 19 15 12 18 14 12 11
100-110 139.87
110-120 32.59 Zonal Lumen Summary
120-130 12.93 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
Lighting: Enclosed and Gasketed — Area — LED/Induction

130-140 8.39 0-30 1360.30 11.3 18.5 90-120 519.46 4.3 7.0
140-150 3.34 0-40 2336.12 19.5 31.7 90-130 532.39 4.4 7.2
150-160 1.19 0-60 4478.63 37.3 60.8 90-150 544.12 4.5 7.2
160-170 0.88 0-90 6823.08 56.9 92.6 90-180 546.38 4.6 7.4
170-180 0.20 0-180 7369.46 61.4 100.0

Total Luminaire Efficiency = 61.6%


CIE Type – Direct REPORT NUMBER: KPB165QLHB
Spacing Lamps: 165 W QL lamp with High Bay Reflector
Plane Criteria
0-180 1.64 Coefficients of Utilization - Zonal Cavity Method
90-270 1.64 Effective Floor Cavity Reflectance 0.20
Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 73 73 73 73 72 72 72 72 68 68 68 66 66 66 63 63 63 62
0-10 216.27 1 68 65 63 61 66 64 62 60 61 60 58 59 58 56 57 56 55 53
10-20 655.22 2 62 58 54 51 61 56 53 50 54 51 49 52 50 48 50 48 47 45
20-30 1103.32 3 57 51 46 42 55 50 46 42 48 44 41 46 43 41 45 42 40 39
30-40 1536.15 4 52 45 40 36 51 44 39 36 43 39 35 41 38 35 40 37 34 33
40-50 1689.60 5 48 40 35 31 47 40 35 31 38 34 30 37 33 30 36 33 30 29
50-60 1298.60 6 44 36 31 27 43 36 30 27 34 30 27 33 29 26 32 29 26 25
60-70 664.63 7 41 33 27 24 40 32 27 24 31 27 23 30 26 23 29 26 23 22
70-80 201.70 8 38 30 24 21 37 29 24 21 28 24 21 28 24 21 27 23 20 19
80-90 26.23 9 35 27 22 19 34 27 22 19 26 22 19 25 21 18 25 21 18 17
90-100 0.27 10 33 25 20 17 32 25 20 17 24 20 17 23 19 17 23 19 17 15
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 1974.81 16.5 26.7 90-120 0.27 0.0 0.0
140-150 0.00 0-40 3510.96 29.3 47.5 90-130 0.27 0.0 0.0
150-160 0.00 0-60 6499.16 54.2 87.9 90-150 0.27 0.0 0.0
160-170 0.00 0-90 7391.72 61.6 100.0 90-180 0.27 0.0 0.0
170-180 0.00 0-180 7391.99 61.6 100.0

1054 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Applications
• Enclosed and gasketed fixtures suitable for use in marine
and wet locations, and in a wide range of industrial, chemical
processing and other areas where flammable gases and vapors
or combustible dusts are present under conditions defined
by the National Electrical Code as Class I, Division 2; Class II,
Division 1 and 2; and Class III. The method of protection for
the Zone 2 Mercmaster is AEx nA nR – Restricted Breathing/
Nonsparking.
• For use in areas of low clearance, low ceiling heights or where
fixture weights must be minimized.
• Suited for use in non-hazardous locations where severe
weather conditions, excessive moisture, dirt, dust or corrosive
atmospheres are present.
• Typical applications include oil refineries, pulp and paper mills,
chemical plants, food-processing areas, inspection facilities, Pendant Mount Fixture Ceiling Mount Fixture with
foundries, power plants, storage areas, waste and sewage with Glass Globe Prismatic Glass Refractor
treatment, parking garages, and other areas where dust, water,
dirt and rough usage are a problem.
Features
Standard Materials
• Energy-efficient, compact fluorescent light sources possess
superior lamp efficiency. • Standard dome or 30° angle reflectors: highly reflective
• Fluorescent provides long lamp life, thereby reducing fiberglass reinforced white polyester to provide strength,
relamping costs. corrosion resistance and excellent photometrics
• “Instant on” nature of this electronically ballasted fluorescent • Fixture housing, mounting hoods, and guards: die-cast,
eliminates the possibility of an extended blackout due to a copperfree (4/10 of 1% max.) aluminum with epoxy finish for
momentary power dip. corrosion resistance
• Exposed hardware: stainless steel. Latch assemblies have

Lighting
• High efficacies (up to 75 lumens per Watt) offer a desirable
low-glare/instant-on alternative to low wattage HID sources. stainless steel bolt and captive nut; reflectors and guards attach
• High output under widely varying conditions: Greater than 90% with stainless steel screws threading into stainless steel inserts
of rated lumens in ambient temperatures from 23 °F to 130 °F / • Globes and glass refractors: heat-resistant prismatic glass
-5 °C to 54 °C. • Polymeric refractor: spun aluminum reflector and a lens made of
• Excellent color rendering (82 CRI) makes it the best choice for an engineered thermoplastic
food processing and inspection facilities. Standard Finishes
• A wide variety of lamp wattages: • Epoxy powder coat finish electrostatically applied for complete,

Lighting: Enclosed and Gasketed — Area — Fluorescent


26 W, 32 W, 42 W, 52 W, 64 W, 84 W. uniform surface protection
• Electronic ballast permits low operating costs with power factor
greater than 99%. Also allows flicker-free starting. Options
• Cold weather starting to a minimum temperature of 0°F/ -18°C. • Fuse can be field installed. Kits include fuse block, wire
• Fixtures are available for operation from an external 125 Vdc connectors and screws for attachment to mounting hood.
source. — Fixtures with fuses do not comply with UL 1598A for marine
• Compact, light-weight low profile design creates ease of listing
installation and maintenance. — Canadian Electrical Code does NOT allow fusing in
• Modular design, with multiple mounting hoods, optics and hazardous locations V
reflectors, permits a wide array of fixtures to meet installation • Guards with gray epoxy painted to match fixtures, supplied with
and lighting needs. stainless steel screws. Add suffix -G.
• Body gaskets and optic gaskets are high temperature silicone • Reflectors are available as standard dome and 30° angle
O-Rings that provide superior sealing. polyester. Order separately.
• Mounting hoods have a high hinge for added safety during
installation and servicing. Certifications and Compliances
• Choice of heat-resistant prismatic glass refractor (NEMA I, III • UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
or V), heat-resistant clear globes, color globes or polymeric 60079-15
refractors (NEMA II, III, IV or V). (Polymeric refractors are not • UL Listed: E10444
listed for Zone 2.) • CSA Standard: C22.2 No. 250, C22.2 No. 137, CAN E60079-0,
CAN E60079-15
• CSA Certified: 025428

V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1055


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Illustrated Features

Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).

Hood/Ballast Gasket
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
Vented Reflectors assures uniform gasket compression.
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for Electrical Protection
Globe Chamber cooler operation. Quickly attach with Ground wire provided to bond mounting
Completely sealed from the ballast furnished stainless steel screws. hood to ballast housing.
housing and outside vapors/air (nA nR).

Epoxy Finish Terminal Blocks (Zone 2)


Ballast housing, hoods and guards are A seven-point terminal block is provided
copperfree aluminum with epoxy powder to facilitate wiring. Terminal block
coat finish. accommodates wire size ranging from #8
to #24 AWG.
Photocell
Installs through knock-out in mounting Stainless Steel Inserts
hoods except cone and ceiling mount. Ballast bodies have stainless steel
Provides continuous on-off dusk-to- threaded inserts to receive stainless steel
Lighting

dawn control. Not for use in hazardous screws for reflectors and guard. Prevents
(classified) areas. Hazardous location "freezing”, allowing guards and reflectors Cooler Operating Cone Hood
rated photocells also available. See to be easily removed and replaced at any Larger sloped surface sheds dusts, dirt
Accessories page. time, without damage to the housing. and combustible fibers providing better
heat dissipation.
Prismatic Glass Globes and Refractors
Heat-resistant globes and glass refractors
Lighting: Enclosed and Gasketed — Area — Fluorescent

and polymeric refractors thread directly


into ballast housing and seal against a
high temperature silicone rubber gasket.
(Polymeric refractors are not listed for
Zone 2 areas.)

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
Stainless Steel Latch Assembly
Captive, stainless steel latch assembly "Safety" High
bolt and nut closes securely, resists attack Hinge
of corrosive atmospheres. Swing-away Extra-high hinge
design simplifies servicing. provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.

V CSA Certification Only.

1056 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Family Tree
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Mounting Hoods
Mounting Hoods
Pendant
Pendant Pendant
PendantCone
Cone Ceiling
Ceiling 25°
25°Stanchion
Stanchion 90°90°Stanchion
Stanchion Wall
WallMount
Mount
KPA-75
KPA-75 KPCH-75
KPCH-75 KPC-75
KPC-75 KPS-125
KPS-75 KPST-125
KPST-75 KPWB-75
KPWB-75
KPA-100
KPA-100 KPCH-100
KPCH-100 KPC-100
KPC-100 KPS-100
KPS-150 KPST-100
KPST-150 KPWB-100
KPWB-100

Globe or Polymeric
Ballast Housing
Ballast Housing Refractor 8” Glass Refractor
Ballast Housings Ballast Housings
8" Glass Refractor
MLBR26FBU (26 W)
MLBG26FBU
Globe (26 W)
or Polymeric Ballast
MLBR32FBU Housings
(32 W)
MLBG32FBU (32 W)
Refractor
MLBG42FBU (42 W) MLBR26F(42
MLBR42FBU (26W)
W)
Ballast
MLBG52FBUHousings
(52 W) MLBR32F(52
MLBR52FBU (32W)
W)
MLBG32F
MLBG57FBU(26 (57&W)32W)
V MLBR52F
MLBR57FBU (52W)
(57W) V
MLBG64F
MLBG64FBU (52(64& 64W)
W) MLBR64FBU
MLBR64F(64 W)
(64W)
MLBG84FBU (84 W) MLBR84FBU (84 W)
MLBG114FBU (114 W) V MLBR114FBU (114 W) V

Polyester Reflectors Polyester Reflectors


Polyester Reflectors Polyester Reflectors

Lighting
Standard Dome
Standard Dome Standard
Standard Dome
Dome

Lighting: Enclosed and Gasketed — Area — Fluorescent


KR2-ST
KR2-ST CMR-4ST
CMR-4ST
30°Angle
30° Angle 30°
30°Angle
Angle
KR2-AN
KR2-AN CMR-4AN
CMR-4AN

GlassGlobes
Globes Glass Refractors
Glass Glass Refractors
Clear VPGL-2HR NEMA I LPG-R1
Clear VPGL-2HR NEMA
Amber VPGL-2AM NEMA III 1 LPG-R1
LPG-R3
Amber VPGL-2AM Polymeric Refractors
Polymeric Refractors NEMA
NEMA V 3 LPG-R3
LPG-R5
Blue
Blue VPGL-2BL
VPGL-2BL NEMA II 2 LPRF-2CP
LPRF-2CP
NEMA NEMA 5 LPG-R5
Green VPGL-2GR NEMA III 3 LPRF-3CP
LPRF-3CP
Green VPGL-2GR NEMA
Red VPGL-2RE NEMA IV 4 LPRF-4CP
LPRF-4CP
Red VPGL-2RE NEMA
NEMA V 5 LPRF-5CP
NEMA LPRF-5CP

Aluminum Guard
Aluminum Guard Three-Way
Three-Way Aluminum Guard
Aluminum Guard
GlobeGuard
Globe Guard Exit Sign
Exit Sign GlassRefractor
Glass Refractor Guard
Guard
KGU2
KGU2 CJEXR KRG2
KRG2
CJEXRN

V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1057


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For Zone 2 Mercmaster III Compact Fluorescent Luminaires
ML A F 84 2 G2 G BU L Z2

Series: Lamp Type: Hub Size: Guard Options: Lamp Options:


ML - F - Fluorescent 2 - 3/4” NPT G - Cast Guard L - Lamp(s) included
Mercmaster 3 - 1” NPT (Glass Refractor Blank - Lamp(s)
III 4 - 1-1/4” NPT & Globe only) excluded
Low Profile Stanchion N - No Guard
5 - 1-1/2” NPT
Stanchion
Mounting Hood: Wattage: Optical Assembly: ➊ Voltage: Suffix:
A - Pendant 26 - One 26 Watt PL-T G2 - VPGL2HR Globe BU - 120 to 277 V, DP - Safety Cable
(Rigid or Flexible) 32 - One 32 Watt PL-T (not for 57, 114 Watt) 50/60 Hz SC - Safety Chain
C - Ceiling 42 - One 42 Watt PL-T G4 - VPGL4HR Globe and 125 Vdc Z2 - Zone 2 Suffix
D - Pendant Cone 52 - Two 26 Watt PL-T (57, 114 Watt only) V A5 - 347 V, 60 Hz V (Required for
R - 90º Stanchion 57 - One 57 Watt PL-T V J1 - NEMA I Glass Refractor AEx nA nR rating)
S - 25º Stanchion 64 - Two 32 Watt PL-T J3 - NEMA III Glass Refractor B - Battery Back-up ➍V
W - Wall 84 - Two 42 Watt PL-T J5 - NEMA V Glass Refractor (42 W max.)
114 - Two 57 Watt PL-T V P2 - NEMA II Polymeric Refractor C - Safety Cable V
P3 - NEMA III Polymeric F - Fused Mtg. Hood ➌V
Refractor (Non-Haz. Loc. only)
P4 - NEMA IV Polymeric P - Non-Haz. Photocell
Refractor (Specify Voltage) V
P5 - NEMA V Polymeric Q - Division 2 Haz.
Refractor Photocell (Specify
Voltage) V
Lighting

T - Terminal Blocks V
V - Vibration Protection V
X - Appledapter ➋
Mounting Hood
Adapter V
Z - Zone 2 suffix
(required for
Ex nR) V
Lighting: Enclosed and Gasketed — Area — Fluorescent

➊ Polymeric refractors suitable for Class II, Groups F & G; NEMA 4X; and Marine Type Electric Fixture Outside Type (Salt Water) only.
Reflectors ordered separately (for use with globe fixtures only): Standard Dome: KR2-ST 30-degree Angle: KR2-AN
➋ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
➌ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➍ Provides a minimum 90 minute back-up power supply in the case of a power loss. Will keep one lamp lit at approximately 50% of its full output (42 W
maximum) V.
V CSA Certification only.

1058 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions
Temperature identification numbers of Mercmaster III Low Profile Fluorescent Fixtures

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Class II, Division 1 Simultaneous Exposure


Ambient Class I, Division 2 Groups E, F and G ➋ (Class I, Div 2 and Class II, Division 1)
Lamp Temp Globe & Glass Polymeric Globe & Glass Polymeric Globe & Glass Polymeric
Watts (°F/°C) ➊ Globe Reflector Refractor Refractor Globe Reflector Refractor Refractor Globe Reflector Refractor Refractor
26 104/40 T3 T3 T3 — T5 T5 T5 T6 T3 T3 T3 —
32 104/40 T3 T3 T3 — T5 T5 T5 T6 T3 T3 T3 —
42 104/40 T3 T3 T3 — T5 T5 T5 T6 T3 T3 T3 —
52 104/40 T2D T2D T3 — T4A T4A T4A T6 T2C T2C T2C —
57 V 104/40 T2D T2D T3 — T4A T4A T4A T6 — — — —
64 104/40 T2D T2D T3 — T4A T4A T4A T6 T2C T2C T2C —
84 104/40 T2C T2C T2D — T3C T3C T3C T6 T2B T2B T2B —
114 V 104/40 T2C T2C T2D — T3C T3C T3C T6 — — — —

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Temp. Range (˚ºF) 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Temp. Range (°C) 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100

Lighting
Lamp Supply Wire Temp. Ambient Temp. Class I, Zone 2, AEx nA nR — Ex nR
Watts (°F/°C) (°F/°C) Globe Globe & Reflector Refractor
26 167/75 104/40 T5 T5 T6
32 167/75 104/40 T5 T5 T6
42 167/75 104/40 T5 T5 T6

Lighting: Enclosed and Gasketed — Area — Fluorescent


52 167/75 104/40 T5 T5 T6
57 V 167/75 104/40 T6 T6 T6
64 167/75 104/40 T5 T5 T6
84 167/75 104/40 T5 T5 T6
114 V 167/75 104/40 T6 T6 T6

“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR Rating
“T”
Number T1 T2 T3 T4 T5 T6
Temperature 574-842 394-572 277-392 214-275 187-212 185
Range (˚ºF)
Temperature 301-450 201-300 136-200 101-135 86-100 85
Range (°C)

➊ Use 167 °F/75 °C rated supply wire.


➋ Fixtures with Polymeric Refractor are listed for Groups F and G only.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1059


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
High Power Factor Electronic Ballast (Min. P.F. 99%), PL-T Lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Catalog Numbers ➋➌
Hub
Lamp Size With Globe With Type V With Type V
Watts (Inches) ➊➍ 8” Glass Refractor ➊➍➎ Polymeric Refractor ➏
Pendant — One Hub (Rigid or Flexible Mounting)
3/4 MLAF262G2N MLAF262J5N MLAF262P5N
1 x 26 W
1 MLAF263G2N MLAF263J5N MLAF263P5N
3/4 MLAF322G2N MLAF322J5N MLAF322P5N
1 x 32 W
1 MLAF323G2N MLAF323J5N MLAF323P5N
3/4 MLAF422G2N MLAF422J5N MLAF422P5N
1 x 42 W
1 MLAF423G2N MLAF423J5N MLAF423P5N
3/4 MLAF522G2N MLAF522J5N MLAF522P5N
2 x 26 W
1 MLAF523G2N MLAF523J5N MLAF523P5N
3/4 MLAF572G4N V MLAF572J5N V MLAF572P5N V
1 x 57 W
1 MLAF573G4N V MLAF572J5N V MLAF572P5N V
3/4 MLAF642G2N MLAF642J5N MLAF642P5N
2 x 32 W
1 MLAF643G2N MLAF643J5N MLAF643P5N
Shown with Glass Globe 3/4 MLAF842G2N MLAF842J5N MLAF842P5N
2 x 42 W
1 MLAF843G2N MLAF843J5N MLAF843P5N
3/4 MLAF1142G4N V MLAF1142J5N V MLAF1142P5N V
2 x 57 W
1 MLAF1143G4N V MLAF1143J5N V MLAF1143P5N V
Lighting

Pendant Cone — One Hub (Rigid or Flexible Mounting)


3/4 MLDF262G2N MLDF262J5N MLDF262P5N
1 x 26 W
1 MLDF263G2N MLDF263J5N MLDF263P5N
3/4 MLDF322G2N MLDF322J5N MLDF322P5N
1 x 32 W
1 MLDF323G2N MLDF323J5N MLDF323P5N
Lighting: Enclosed and Gasketed — Area — Fluorescent

3/4 MLDF422G2N MLDF422J5N MLDF422P5N


1 x 42 W
1 MLDF423G2N MLDF423J5N MLDF423P5N
3/4 MLDF522G2N MLDF522J5N MLDF522P5N
2 x 26 W
1 MLDF523G2N MLDF523J5N MLDF523P5N
3/4 MLDF572G4N V MLDF572J5N V MLDF572P5N V
1 x 57 W
1 MLDF573G4N V MLDF573J5N V MLDF573P5N V
3/4 MLDF642G2N MLDF642J5N MLDF642P5N
2 x 32 W
1 MLDF643G2N MLDF643J5N MLDF643P5N
Shown with 8” Glass Refractor 3/4 MLDF842G2N MLDF842J5N MLDF842P5N
2 x 42 W
1 MLDF843G2N MLDF843J5N MLDF843P5N
3/4 MLDF1142G4N V MLDF1142J5N V MLDF1142P5N V
2 x 57 W
1 MLDF1143G4N V MLDF1143J5N V MLDF1143P5N V

➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
➌ Add L after voltage suffix to include lamp.
➍ Add Z2 suffix for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
➎ To order fixture with NEMA Type I or III glass refractor, change J5 to J1 or J3 respectively.
➏ To order fixture with NEMA Type II, III, or IV polymeric refractor, change P5 to P2, P3 or P4 respectively. Polymeric refractor fixtures are UL Listed and CSA
Certified for Class II, Division 1 and 2, Groups F and G; Class III; Marine Outdoor Salt Water (UL1598A); NEMA 4X and CSA Type 4X.
V CSA Certification only.

1060 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
High Power Factor Electronic Ballast (Min. P.F. 99%), PL-T Lamps.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Catalog Numbers ➋➌
Hub
Lamp Size With Globe With Type V With Type V
Watts (Inches) ➊➍ 8” Glass Refractor ➊➍➎ Polymeric Refractor ➏
Ceiling — Five Hubs, Four Close-Up Plugs
3/4 MLCF262G2N MLCF262J5N MLCF262P5N
1 x 26 W
1 MLCF263G2N MLCF263J5N MLCF263P5N
3/4 MLCF322G2N MLCF322J5N MLCF322P5N
1 x 32 W
1 MLCF323G2N MLCF323J5N MLCF323P5N
3/4 MLCF422G2N MLCF422J5N MLCF422P5N
1 x 42 W
1 MLCF423G2N MLCF423J5N MLCF423P5N
3/4 MLCF522G2N MLCF522J5N MLCF522P5N
2 x 26 W
1 MLCF523G2N MLCF523J5N MLCF523P5N
3/4 MLCF572G4N V MLCF572J5N V MLCF572P5N V
1 x 57 W
1 MLCF573G4N V MLCF573J5N V MLCF573P5N V
3/4 MLCF642G2N MLCF642J5N MLCF642P5N
2 x 32 W
1 MLCF643G2N MLCF643J5N MLCF643P5N
3/4 MLCF842G2N MLCF842J5N MLCF842P5N
Shown with Polymeric Refractor 2 x 42 W
1 MLCF843G2N MLCF843J5N MLCF843P5N
3/4 MLCF1142G4N V MLCF1142J5N V MLCF1142P5N V
2 x 57 W
1 MLCF1143G4N V MLCF1143J5N V MLCF1143P5N V

Lighting
Wall Bracket — Five Hubs, Four Close-Up Plugs
3/4 MLWF262G2N MLWF262J5N MLWF262P5N
1 x 26 W
1 MLWF263G2N MLWF263J5N MLWF263P5N
3/4 MLWF322G2N MLWF322J5N MLWF322P5N
1 x 32 W
1 MLWF323G2N MLWF323J5N MLWF323P5N

Lighting: Enclosed and Gasketed — Area — Fluorescent


3/4 MLWF422G2N MLWF422J5N MLWF422P5N
1 x 42 W
1 MLWF423G2N MLWF423J5N MLWF423P5N
3/4 MLWF522G2N MLWF522J5N MLWF522P5N
2 x 26 W
1 MLWF523G2N MLWF523J5N MLWF523P5N
3/4 MLWF572G4N V MLWF572J5N V MLWF572P5N V
1 x 57 W
1 MLWF573G4N V MLWF573J5N V MLWF573P5N V
3/4 MLWF642G2N MLWF642J5N MLWF642P5N
2 x 32 W
1 MLWF643G2N MLWF643J5N MLWF643P5N
3/4 MLWF842G2N MLWF842J5N MLWF842P5N
Shown with 8” Glass Refractor 2 x 42 W
1 MLWF843G2N MLWF843J5N MLWF843P5N
3/4 MLWF1142G4N V MLWF1142J5N V MLWF1142P5N V
2 x 57 W
1 MLWF1143G4N V MLWF1143J5N V MLWF1143P5N V

➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
➌ Add L after voltage suffix to include lamp.
➍ Add Z2 suffix for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
➎ To order fixture with NEMA Type I or III glass refractor, change J5 to J1 or J3 respectively.
➏ To order fixture with NEMA Type II, III, or IV polymeric refractor, change P5 to P2, P3 or P4 respectively. Polymeric refractor fixtures are UL Listed and CSA
Certified for Class II, Division 1 and 2, Groups F and G; Class III; Marine Outdoor Salt Water (UL1598A); NEMA 4X and CSA Type 4X.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1061


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Description Hub Size (Inches) Catalog Number


Pendant
One Hub, 3/4 KPA-75
Rigid or Flexible Mounting
1 KPA-100

Pendant Cone
Five Hubs, 3/4 KPCH-75
Four Close-Up Plugs
1 KPCH-100

Ceiling
Five Hubs, 3/4 KPC-75
Four Close-Up Plugs
1 KPC-100

Wall
Five Hubs, 3/4 KPWB-75
Four Close-Up Plugs
1 KPWB-100

25° Stanchion
Lighting

One Hub 1-1/4 KPS-125


1-1/2 KPS-150

90° Stanchion
One Hub 1-1/4 KPST-125
Lighting: Enclosed and Gasketed — Area — Fluorescent

1-1/2 KPST-150

Ballast Bodies
Catalog Numbers
Lamp For Glass Globe or For Glass
Wattage Polymeric Refractor ➊➋ Refractor ➋
Compact PL-T Fluorescent — 120 V to 277 V, 50/60 Hz and 125 Vdc
1 x 26 W MLBG26FBU MLBR26FBU
1 x 32 W MLBG32FBU MLBR32FBU
1 x 42 W MLBG42FBU MLBR42FBU
2 x 26 W MLBG52FBU MLBR52FBU
1 x 57 W — MLBR57F V
2 x 32 W MLBG64FBU MLBR64FBU
Ballast Body for Glass Globe Ballast Body for 2 x 42 W MLBG84FBU MLBR84FBU
or Polymeric Refractor ➊ Glass Refractor 2 x 57 W — MLBR114F V

➊ Polymeric refractor not listed for Class I, Zone 2 areas.


➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
V CSA Certification only.

1062 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Item Description Catalog Number ➌


White Polyester Reflectors – Furnished with stainless steel screws
For Globe Fixtures
Standard Dome KR2-ST
30° Angle KR2-AN

Standard Dome
For Glass Refractor Fixtures ➊
Standard Dome CMR-4ST ➋
30° Angle CMR-4AN ➋

30° Angle Dome


Prismatic Glass Globes — Heat-Resistant ➌
Clear VPGL-2HR
Amber ➍ VPGL-2AM
Blue ➍ VPGL-2BL
Green ➍ VPGL-2GR
Red ➍ VPGL-2RE
Clear — 57/114 Watt V VPGL-4HR

Lighting
Closed Prismatic Glass Refractors — All Heat-Resistant ➌
NEMA Type I LPG-R1
NEMA Type III LPG-R3
NEMA Type V LPG-R5

Closed Prismatic Polymeric Refractors — Not Listed for Class I, Zone 2 Areas

Lighting: Enclosed and Gasketed — Area — Fluorescent


NEMA Type II LPRF-2CP
NEMA Type III LPRF-3CP
NEMA Type IV LPRF-4CP
NEMA Type V LPRF-5CP
Guards

Globe Guard KGU2

Glass Refractor Guard KRG2


Globe Guard Glass Refractor Guard
Globe Guard — 57/114 W V KPGU400

Globe Guard for 57 W Only


➊ Fixtures with refractors are not UL Listed when used with reflectors.
➋ Standard dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
➌ Silicone or Teflon V coated globes are available. Contact your local sales representative.
➍ Non hazardous rated globes for special applications.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1063


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Item Description Catalog Number


Replacement Optic Gaskets — Silicone rubber
Globe and Polymeric Refractor Gasket VPGL-GK
Glass Refractor Gasket KRF-GK

Replacement Lamp
Mercmaster III Low Profile Compact Fluorescent
Lamp Type Lamp Base Wattage Catalog Number
PL-T GX24q-3 26 PLT26
PL-T GX24q-3 32 PLT32
PL-T GX24q-4 42 PLT42
PL-T GX24q-5 57 PLT57 V
Replacement Socket
For 26 W, 32 W and 42 W PLT Lamps listed above PLT32RS
For 57 W PLT Lamp PLT57RS V

Three-Way Exit Sign ➊


Lighting

Epoxy enameled steel – 6”/152.4 mm high red lettering CJEXRN

Mounts to Globe Ballast Housing in place of guard.

Single Sided Exit Sign ➊


Lighting: Enclosed and Gasketed — Area — Fluorescent

Epoxy enameled steel – 6”/152.4 mm high red lettering AEXR-15R


Mounts to Globe Ballast Housing in place of guard

Retrofit Pendant Mounting Adapter


Permits use of Mercmaster III pendant hood LPAD-1
with 3/4” hub on existing V-51 mounting hood

Fuse Kit ➋
2-Amp time delay fuse MLF2

➊ Consult your local sales representative for classified area suitability. Not listed for Zone 2 areas.
➋ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification only.

1064 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Electrical Specifications
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Fixtures Outside Type (Salt Water)
Class I, Zone 2, AEx nA nR IIC (Z2) Class III Type 4X
Class I, Zone 2, Ex nR IIC (Z) V Simultaneous Exposure (Class I, Division 2/ IP66
Class II, Division 1)

Line Voltage Type of Ballast Starting and Operating Amps Total Watts
26 Watt PL-T Fluorescent
120 Electronic .250 28
277 Electronic .110 28
347 Electronic .080 27
32 Watt PL-T Fluorescent
120 Electronic .300 36
277 Electronic .130 36
347 Electronic .150 36
42 Watt PL-T Fluorescent
120 Electronic .410 48
277 Electronic .180 48
347 Electronic .140 43
52 Watt PL-T Fluorescent
120 Electronic .460 56
277 Electronic .220 56
347 Electronic .170 54
57 Watt PL-T Fluorescent V
120 Electronic .480 58
277 Electronic .210 57
347 Electronic .180 61
64 Watt PL-T Fluorescent
120 Electronic .580 69
277 Electronic .260 69
347 Electronic .190 66

Lighting
84 Watt PL-T Fluorescent
120 Electronic .760 91
277 Electronic .320 91
347 Electronic .280 86
114 Watt PL-T Fluorescent V
120 Electronic .960 116
277 Electronic .420 114

Lighting: Enclosed and Gasketed — Area — Fluorescent


347 Electronic .360 122
Fuse catalog number: MLF2 (1 required for 120 V or 277 V) – 2-Amp fuse, time delay.
Minimum starting temperature: 0 °F/-18 °C

Energy Efficiency and Lamp Life Comparison Lumen Output Comparison


Rated Average
Lamp Type Watts Lumens Life (Hours) Light Output as Function of Temperature
Incandescent 100 1750 750
Incandescent 150 2880 750
Incandescent 200 (PS-25, PS-30) 3710 750 Relative
Light
Incandescent 200 (A-23) 4010 750
Output %
PL-T Fluorescent 26 1800 10,000
PL-T Fluorescent 32 2400 10,000
PL-T
PL-T Fluorescent 42 3200 10,000
(Amalgam)
PL-T Fluorescent 52 3600 10,000 Quad ---
PL-T Fluorescent 57 V 4300 12,000
PL-T Fluorescent 64 4800 10,000 Degrees F
PL-T Fluorescent 84 6400 10,000
PL-T Fluorescent 114 V 8600 12,000 High lumen output of the amalgam technology lamp vs. the
reduced light output at variable temperatures from a typical
V CSA Certification only. compact fluorescent lamp.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1065


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Dimensions
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Dimensions
Pendant Pendant Cone Ceiling 25 Stanchion
1.17"/ 13.62"/
12.06"/ 12.06"/
29.7 mm 306.3 mm 346.9 mm
306.3 mm
12.06"/ /
27” 0”/
306.3 mm 15. .9 mm 2.0 mm
5.59"/ 387 50.
8
142.0 mm
5”/
1.75"/ 9.2 0 mm
5.
44.5 mm 23
/
03”
12. .6 mm
Wall Mount 305

17.00"/
t
431.8 mm Se w
re
Sc 9”/
10.93”/ 7.5 8 mm
.
277.6 mm 192
25°

12.03”/
305.6 mm Polyester Reflector
17.23”/
437.6 mm
5.90"/
9.79”/ 149.9 mm
248.7 mm

Globe or Polymeric 8" Glass Refractor 18.70"/


Refractor Ballast Housing Ballast Housing 475.0 mm

13.38"/ 13.38"/
339.9 mm 339.9 mm 12.03”/ 2.75"/
305.6 mm 69.9 mm
3.04"/
77.2 mm 3.04"/ 10.17"/
77.2 mm 258.3 mm
Lighting

5.50"/ "/
139.7 mm 2.48"/ 7.75"/ .06 m
11.12"/ 63.0 mm 17 .3 m
196.9 mm 3
282.4 mm 43
11.12"/
282.4 mm

Globe and Refractors Aluminum Guards


5.50"/ 7.94"/
5.50"/ 139.7 mm 11.00"/
139.7 mm 7.75"/ 201.6 mm
279.4 mm
196.9 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent

8.00"/ 7.25"/ 8.50"/ 7.50"/


203.2 mm 10.75"/ 184.2 mm 215.9 mm 190.5 mm
237.1 mm

6.75"/ 8.88"/
4.50"/ 171.5mm 5.88"/ 225.6 mm
12.38"/ 149.4 mm
114.3 mm 314.5 mm

Accessory Weights ➊
Ballast Housings and Refractors, Globe,
Mounting Hoods Wt. Lbs/Kgs Guards and Reflectors Wt. Lbs/Kgs
Pendant 2.25/1.0 8” Glass Refractor 5.25/2.4
Pendant Cone 2.50/1.1 Glass Globe 3.75/1.7
Ceiling 3.00/1.4 Glass Globe — 57/114 W V 8.35/ 3.8
Wall Mount 4.00/1.8 Polymeric Refractor ➋ 2.43/1.1
25° Stanchion 3.25/1.5 Glass Refractor Guard 1.00/0.5
90° Stanchion 3.75/1.7 Globe Guard 1.00/0.5
Globe/Polymeric Refractor Housing 5.60/2.5 Globe Guard — 57/114 W V 2.00/0.9
Glass Refractor Housing 6.50/2.9 Standard Dome 2.50/1.1
30° Angle 2.50/1.1
Exit Sign ➋ 5.00/2.3
➊ Weights are approximate.
➋ Not listed for Class I, Zone 2 areas.
V CSA Certification only.

1066 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
EFDB™ Series Factory-Sealed Photocontrol
Explosionproof, Dust-Ignitionproof
For use with Threaded Metal Conduit.

Explosionproof Remote
Photocontrol – Single Gang
Class I, Groups B, C, D
Class II, Groups, E, F, G
Class III

Applications Hub Size Max Max Catalog Number ➋


• Factory-sealed control stations (Inches) Voltage Current (A) VA Dead End Feed Through
confine arcing of device within
the enclosure, preventing ignition 1/2 120 8.3 1000 EFDB150PC120 EFDCB150PC120
of atmospheres. 3/4 120 8.3 1000 EFDB175PC120 EFDCB175PC120
• Used in classified areas where
flammable vapors, gases or highly 1 120 8.3 1000 EFDB110PC120 EFDCB110PC120
combustible dusts are present.
• For installation in chemical and Replacement Parts for Remote Photocontrol
petrochemical plants, refineries and Catalog Number
other process industries, or where
corrosive elements are present. Max Complete Cover Photocontrol
Voltage Current (A) VA Assembly Only
Features
120 8.3 1000 EFKB-PC120 PC120X
• Finish is an epoxy powder coat for
enhanced corrosion resistance. 208-277 3.5 1000 EFKB-PC277 PC277X
• Corrosion-resistant stainless steel
hex-head captive screws hold cover
to body.
EFDB Single Gang
• Factory-sealed enclosure eliminates
5/16 Dia. (2) Mtg. Holes
need for adding sealing fittings and
compound at each conduit entrance 12-24 x 1
(4) Screws
(for Groups C & D applications).
• Accurately tapped, tapered
hubs for tight, rigid joints and
ground continuity.
• Smooth, rounded integral
bushing in each hub protects

Lighting
A
conductor insulation. 4.63”/ 5.41”/
B 117.6 mm 137.4 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent


C
2.31”/
58.7 mm 4.81”/
3.00”/ 122.2 mm
76.2 mm

Hub Size Dimensions in Inches


(Inches) A B C
1/2 & 3/4 5.38 6.13 .78
1 5.50 6.31 .94

Turn On 1 to 3 footcandles; Turn On/Turn Off ratio: 1:3, Temperature range: -30 °F through 140 °F.
For Class I, Group B, external seals must be installed at each conduit entrance.
 For 208-277 volt rating, change 120 suffix to 277; current ratings become 3.5 A.
➋ Standard catalog number represents malleable iron body with aluminum cover. For aluminum body, add suffix -A.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1067


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on a fixture with For candlepower values of fixtures with a 26
a 32 W compact fluorescent PL-T lamp (2,400 W PL-T lamp (1,800 lumens), multiply by 0.75.
lumens). For candlepower values of fixtures with a 42 W
PL-T lamp (3,200 lumens), multiply by 1.34.

Zone Lumens Total Luminaire Efficiency = 86.1%


0-10 10.23 CIE Type – Semi-Direct REPORT NUMBER: MLF32G
10-20 34.38 Spacing Lamps: One 32 W lamp with Globe only *
20-30 64.27 Plane Criteria
30-40 105.64 0-180 2.80 Coefficients of Utilization - Zonal Cavity Method
40-50 151.34 90-270 2.68 Effective Floor Cavity Reflectance 0.20
50-60 194.61 Diagonal 2.50 % Ceiling Rcc 80 70 50 30 10 0
60-70 224.08 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 243.06 Zonal Lumen Summary 0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 58 58 58 53
80-90 248.58 Zone Lumens % Lamp % Fixture 1 81 75 70 65 75 70 65 61 60 56 53 51 48 45 43 40 38 34
90-100 241.28 0-30 108.88 4.5 5.3 2 72 63 55 49 66 58 51 46 50 44 40 42 37 34 34 31 28 24
100-110 220.55 0-40 214.52 8.9 10.4 3 64 53 45 38 59 49 42 36 42 36 31 35 30 26 29 25 22 18
110-120 182.81 0-60 560.47 23.4 27.1 4 58 46 38 31 53 43 35 29 36 30 25 30 25 21 25 21 17 14
120-130 109.74 0-90 1276.18 53.2 61.8 5 53 41 32 26 49 38 30 24 32 26 21 27 21 17 22 18 14 11
130-140 33.74 90-120 644.64 26.9 31.2 6 48 36 28 22 44 33 26 20 28 22 17 24 19 15 19 15 12 9
140-150 1.67 90-130 754.38 31.4 36.5 7 45 32 24 18 41 30 22 17 25 19 15 21 16 12 18 13 10 8
150-160 0.14 90-150 789.80 32.9 36.5 8 41 29 21 16 38 27 20 15 23 17 13 19 14 11 16 12 9 7
160-170 0.00 90-180 789.94 32.9 38.2 9 38 26 19 14 35 24 18 13 21 15 11 18 13 9 15 11 8 6
170-180 0.00 180-0 2066.12 86.1 100.0 10 36 24 17 12 33 22 16 11 19 14 10 16 12 8 13 10 7 5

Zone Lumens Total Luminaire Efficiency = 74.4%


0-10 34.45 CIE Type – Direct REPORT NUMBER: MLF32ST
10-20 105.58 Spacing Lamps: One 32 W lamp with Standard Dome Reflector *
20-30 178.09 Plane Criteria
30-40 242.36 0-180 1.68 Coefficients of Utilization - Zonal Cavity Method
40-50 291.93 90-270 1.64 Effective Floor Cavity Reflectance 0.20
Lighting

50-60 323.02 Diagonal 1.74 % Ceiling Rcc 80 70 50 30 10 0


60-70 314.54 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 216.11 Zonal Lumen Summary 0 89 89 89 89 86 86 86 86 83 83 83 79 79 79 76 76 76 74
80-90 76.59 Zone Lumens % Lamp % Fixture 1 79 75 71 67 77 73 69 66 70 67 64 66 64 62 64 62 60 58
90-100 3.47 0-30 318.12 13.3 17.8 2 70 63 57 52 68 62 56 51 59 54 50 56 52 49 54 51 48 46
100-110 0.25 0-40 560.48 23.4 31.4 3 63 54 47 41 61 53 46 41 50 45 40 48 43 39 46 42 39 37
110-120 0.00 0-60 1175.44 49.0 65.8 4 57 47 40 34 55 46 39 34 44 38 33 42 37 33 40 36 32 30
Lighting: Enclosed and Gasketed — Area — Fluorescent

120-130 0.00 0-90 1782.68 74.3 99.8 5 52 41 34 28 50 40 33 28 39 33 28 37 32 27 36 31 27 25


130-140 0.00 90-120 3.72 0.2 0.2 6 48 37 29 24 46 36 29 24 35 28 24 33 28 23 32 27 23 21
140-150 0.00 90-130 3.72 0.2 0.2 7 44 33 26 21 43 32 26 21 31 25 21 30 24 20 29 24 20 19
150-160 0.00 90-150 3.72 0.2 0.2 8 41 30 23 18 40 29 23 18 28 22 18 27 22 18 26 21 18 16
160-170 0.00 90-180 3.72 0.2 0.2 9 38 27 21 16 37 27 20 16 26 20 16 25 20 16 24 19 16 14
170-180 0.00 180-0 1786.40 74.4 100.0 10 36 25 19 14 35 25 18 14 24 18 14 23 18 14 22 18 14 13

Zone Lumens Total Luminaire Efficiency = 68.5%


0-10 27.92 CIE Type – Direct REPORT NUMBER: MLF32AN
10-20 86.63 Spacing Lamps: One 32 W lamp with 30° Angle Dome Reflector *
20-30 147.04 Plane Criteria
30-40 206.00 0-180 2.20 Coefficients of Utilization - Zonal Cavity Method
40-50 241.56 90-270 1.76 Effective Floor Cavity Reflectance 0.20
50-60 246.42 Diagonal 1.72 % Ceiling Rcc 80 70 50 30 10 0
60-70 226.09 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 191.43 Zonal Lumen Summary 0 80 80 80 80 78 78 78 78 73 73 73 69 69 69 65 65 65 63
80-90 143.57 Zone Lumens % Lamp % Fixture 1 71 66 62 59 68 64 60 57 60 57 54 56 54 52 53 51 49 47
90-100 85.71 0-30 261.58 10.9 15.9 2 63 56 50 45 61 54 49 44 51 46 43 48 44 41 45 42 39 37
100-110 34.86 0-40 467.59 19.5 28.4 3 57 48 42 36 54 47 41 36 44 39 34 41 37 33 39 35 32 30
110-120 6.37 0-60 955.56 39.8 58.1 4 51 42 35 30 49 41 34 29 38 33 28 36 31 27 34 30 26 25
120-130 0.80 0-90 1516.66 63.2 92.2 5 47 37 30 25 45 36 30 25 34 28 24 32 27 23 30 26 22 21
130-140 0.00 90-120 126.94 5.3 7.7 6 43 33 26 21 41 32 26 21 30 25 20 29 24 20 27 23 19 18
140-150 0.00 90-130 127.74 5.3 7.8 7 40 30 23 19 38 29 23 18 27 22 18 26 21 17 24 20 17 15
150-160 0.00 90-150 127.74 5.3 7.8 8 37 27 21 16 35 26 20 16 25 19 16 23 19 15 22 18 15 13
160-170 0.00 90-180 127.74 5.3 7.8 9 34 25 18 14 33 24 18 14 23 17 14 22 17 14 20 16 13 12
170-180 0.00 180-0 1644.40 68.5 100.0 10 32 22 17 13 31 22 16 13 21 16 12 20 15 12 19 15 12 10

1068 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

* Photometric data is based on a fixture with For candlepower values of fixtures with a 26
a 32 W compact fluorescent PL-T lamp (2,400 W PL-T lamp (1,800 lumens), multiply by 0.75.
lumens). For candlepower values of fixtures with a 42 W
PL-T lamp (3,200 lumens), multiply by 1.34.

Zone Lumens Total Luminaire Efficiency = 80.9%


0-10 18.85 CIE Type – Semi-Direct REPORT NUMBER: MLF64G
10-20 63.99 Spacing Lamps: Two 32 W lamps with Globe only *
20-30 125.20 Plane Criteria
30-40 205.98 0-180 2.24 Coefficients of Utilization - Zonal Cavity Method
40-50 294.73 90-270 2.64 Effective Floor Cavity Reflectance 0.20
50-60 370.74 Diagonal 2.74 % Ceiling Rcc 80 70 50 30 10 0
60-70 425.25 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 457.39 Zonal Lumen Summary 0 89 89 89 89 83 83 83 83 73 73 73 63 63 63 55 55 55 51
80-90 463.07 Zone Lumens % Lamp % Fixture 1 76 71 66 61 71 66 61 57 57 53 50 48 45 43 41 38 36 32
90-100 445.19 0-30 208.05 4.3 5.4 2 68 59 52 46 62 55 48 43 47 42 37 40 36 32 33 30 27 23
100-110 402.45 0-40 414.02 8.6 10.7 3 61 50 42 36 56 47 40 34 40 34 29 33 29 25 28 24 21 18
110-120 328.71 0-60 1079.50 22.5 27.8 4 55 44 35 29 50 40 33 27 34 28 24 29 24 20 24 20 17 14
120-130 203.51 0-90 2425.21 50.5 62.5 5 50 38 30 24 46 35 28 23 30 24 19 25 20 17 21 17 14 11
130-140 69.29 90-120 1176.35 24.5 30.3 6 46 34 26 20 42 31 24 19 27 21 16 23 18 14 19 15 11 9
140-150 8.05 90-130 1379.86 28.7 35.5 7 42 30 23 17 39 28 21 16 24 18 14 20 15 12 17 13 10 8
150-160 0.13 90-150 1457.21 30.4 35.5 8 39 27 20 15 36 25 19 14 22 16 12 18 14 10 15 11 8 6
160-170 0.00 90-180 1457.34 30.4 37.5 9 36 25 18 13 33 23 17 12 20 14 11 17 12 9 14 10 7 5
170-180 0.00 180-0 3882.55 80.9 100.0 10 34 22 16 11 31 21 15 11 18 13 9 15 11 8 13 9 6 5

Zone Lumens Total Luminaire Efficiency = 68.7%


0-10 62.95 CIE Type – Direct REPORT NUMBER: MLF64ST
10-20 193.68
Spacing Lamps: Two 32 W lamps with Standard Dome Reflector *
20-30 332.52 Plane Criteria
30-40 456.54 0-180 1.62 Coefficients of Utilization - Zonal Cavity Method
40-50 551.40 90-270 1.66 Effective Floor Cavity Reflectance 0.20

Lighting
50-60 602.56 Diagonal 1.84 % Ceiling Rcc 80 70 50 30 10 0
60-70 573.69 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 386.39 Zonal Lumen Summary 0 82 82 82 82 80 80 80 80 76 76 76 73 73 73 70 70 70 69
80-90 133.48 Zone Lumens % Lamp % Fixture 1 73 69 65 62 71 67 64 61 64 62 59 62 59 57 59 57 56 54
90-100 2.39 0-30 589.15 12.3 17.9 2 65 58 53 48 63 57 52 48 55 50 46 52 49 45 50 47 44 43
100-110 0.00 0-40 1045.70 21.8 31.7 3 59 50 44 38 57 49 43 38 47 42 37 45 40 37 43 39 36 34
110-120 0.00 0-60 2199.66 45.8 66.7 4 53 44 37 31 51 43 36 31 41 35 31 39 34 30 38 33 30 28

Lighting: Enclosed and Gasketed — Area — Fluorescent


120-130 0.00 0-90 3293.22 68.6 99.9 5 48 38 31 26 47 38 31 26 36 30 26 35 29 25 33 29 25 24
130-140 0.00 90-120 2.39 0.0 0.1 6 44 34 27 22 43 33 27 22 32 26 22 31 26 22 30 25 22 20
140-150 0.00 90-130 2.39 0.0 0.1 7 41 31 24 19 40 30 24 19 29 23 19 28 23 19 27 22 19 17
150-160 0.00 90-150 2.39 0.0 0.1 8 38 28 21 17 37 27 21 17 26 21 17 25 20 17 24 20 16 15
160-170 0.00 90-180 2.39 0.0 0.1 9 35 25 19 15 34 25 19 15 24 19 15 23 18 15 22 18 15 13
170-180 0.00 180-0 3295.61 68.7 100.0 10 33 23 17 13 32 23 17 13 22 17 13 21 17 13 21 16 13 12

Zone Lumens Total Luminaire Efficiency = 62.8%


0-10 50.16 CIE Type – Direct REPORT NUMBER: MLF64AN
10-20 156.40 Spacing Lamps: Two 32 W lamps with 30° Angle Dome Reflector *
20-30 272.40 Plane Criteria
30-40 383.54 0-180 2.16 Coefficients of Utilization - Zonal Cavity Method
40-50 446.01 90-270 1.70 Effective Floor Cavity Reflectance 0.20
50-60 442.26 Diagonal 1.80 % Ceiling Rcc 80 70 50 30 10 0
60-70 405.74 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 352.81 Zonal Lumen Summary 0 74 74 74 74 71 71 71 71 67 67 67 63 63 63 60 60 60 58
80-90 269.34 Zone Lumens % Lamp % Fixture 1 65 61 57 54 62 59 55 52 55 52 50 52 49 47 48 47 45 43
90-100 159.49 0-30 478.96 10.0 15.9 2 58 51 46 42 55 50 45 41 46 42 39 44 40 37 41 38 36 34
100-110 63.13 0-40 862.50 18.0 28.6 3 52 44 38 33 50 43 37 33 40 35 31 38 34 30 35 32 29 27
110-120 11.54 0-60 1750.77 36.5 58.1 4 47 39 32 27 45 37 31 27 35 30 26 33 29 25 31 27 24 22
120-130 1.54 0-90 2778.65 37.9 92.2 5 43 34 28 23 41 33 27 23 31 26 22 29 25 21 27 24 21 19
130-140 0.00 90-120 234.15 4.9 7.8 6 40 30 24 20 38 29 24 19 28 23 19 26 22 18 25 21 18 16
140-150 0.00 90-130 235.69 4.9 7.8 7 36 27 21 17 35 26 21 17 25 20 16 24 19 16 22 18 15 14
150-160 0.00 90-150 235.69 4.9 7.8 8 34 25 19 15 32 24 19 15 23 18 14 22 17 14 20 16 14 12
160-170 0.00 90-180 235.69 4.9 7.8 9 31 22 17 13 30 22 17 13 21 16 13 20 15 12 19 15 12 11
170-180 0.00 180-0 3014.34 62.8 100.0 10 29 21 15 12 28 20 15 12 19 15 11 18 14 11 17 14 11 10

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1069


© September 2010
FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations

Class I, Division 2, Groups A, B, C, D Marine Type Electric Fixture


Class I, Zone 2, Group IIC Outside Type (Salt Water) *
Class II Division 1, Groups E, F, G Type 4X
Class II, Division 2, Groups F, G Wet Locations

Applications
• For use in hazardous locations defined by the NEC as Class I,
Division 2, Groups A, B, C and D; Class II, Division 2, Groups
F and G; Marine Outdoor Salt Water; UL1598A; Type 4X; and
Class I, Zone 2 II C.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor or outdoor use where protection against dirt, water
and moisture is necessary.
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general manufacturing
facilities.
Features
• Stainless steel hubs (3/4”) provided as standard.
• Ballast options for nearly all U.S. and foreign voltage and
frequency combinations are available.
• Low operating costs provide more lumens per Watt than
incandescent fixtures.
• Impact-resistant polycarbonate lens is hinged to allow easy
access to lamp compartment.
• Corrosion-resistant fiberglass reinforced polyester housing.
• Actuator allows access to lamps and ballast compartment –
no tools required.
• Latch assembly and elastomer type gasket provide positive Compliancies and Certifications
seal from water ingress. • UL Standard: UL 1598, UL 844, UL 60079-0, UL 60079-15
• Safety switch (supplied as standard) disconnects power to • UL Listed: E10794
Lighting

lamps and ballast when lens is open. • CSA Standard: C22.2 No. 250, C22. 2 No. 137, CAN E60079-0,
• Reflector is hinged for easy single-handed entry to ballast CAN E60079-15
compartment. • cUL Listed: E10794
• Actuator can be removed for tamper-resistant applications.
Standard Materials
• Housing: fiberglass reinforced polyester
• Lens: polycarbonate
Lighting: Enclosed and Gasketed — Area — Fluorescent

• Gasket: elastomer
• Hubs: stainless steel
• Lampholders: polycarbonate
• Internal reflector: highly reflective white polycarbonate
• Fixed surface mount: (2) 14-gauge stainless steel
• Adjustable wall mount: (2) copperfree (4/10 of 1% max.)
aluminum
• 45° fixed wall mount: (2) 11-gauge (1/8”) stainless steel
• Chain ring bolt: set of 2 zinc plated steel (internal diameter .78”)
Options
• Individually fused ballast. Add suffix -F.
• Terminal block. Add suffix -T.
• Emergency battery pack. Add suffix -EL.
• Emergency light capability in moments of power interruption.
Luminaire automatically switches to emergency mode, keeping
one lamp illuminated for a minimum of 90 minutes. When AC
power is restored, battery automatically recharges in 24 hours.
Initial light output is 600-700 lumens.

* Does not apply to fixtures with fusing.

1070 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations

Class I, Division 2, Groups A, B, C, D Marine Type Electric Fixture


Class I, Zone 2, Group IIC Outside Type (Salt Water) *
Class II Division 1, Groups E, F, G Type 4X
Class II, Division 2, Groups F, G Wet Locations

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FV Series Nonmetallic Fluorescent Luminaires
FV P 2 32 BU SO F

Series: Number of Lamps: Voltage ①: Options:


FV - FV Series 2 - 2 Lamps 347 - 347 V 60 Hz V F - Fuse
3 - 3 Lamps (32 W only) BU - 120-277 V 50/60 Hz ③ T - Terminal Block (6 Point)
4 - 4 Lamps (40 W only, EL - Emergency Battery Pack ②
F40BX)

Lamp Type: Wattage: Ballast Type:


P - "PL" Fluorescent (F40BX) 32 - 32 W (T8) SS - Solid State (for 347 V T-12)
R - Rapid Start 40 - 40 W (T12-RS, F40BX)
H - High Output 44 - 44 W (T-8-HO)
60 - 60 W (T-12-HO)

Number of Lamp Lamp Hub Size Overall Fixture Length Catalog


Lamps ⑥ Watts Type (Inches) (Inches/Millimeters) Volts Number ⑦
2 40 F40BX 3/4 31/787.4 120-277 FVP240BU
2 40 F40BX 3/4 31/787.4 347 FVP240-347 V

Lighting
4 40 F40BX 3/4 55/1397 120-277 FVP440BU
4 40 F40BX 3/4 55/1397 347 FVP440-347 V
2 32 T8 3/4 55/1397 120-277 FVR232BU
2 32 T8 3/4 55/1397 347 FVR232-347S0 V
2 44 T8-HO 3/4 55/1397 120-277 FVH244BU

Lighting: Enclosed and Gasketed — Area — Fluorescent


2 44 T8-HO 3/4 55/1397 347 FVH244-347S0 V
2 40 T12 3/4 55/1397 120-277 FVR240BU
2 40 T12 3/4 55/1397 347 FVR240-347SS V
2 60 T12-HO 3/4 55/1397 120-277 FVH260BU
2 60 T12-HO 3/4 55/1397 347 FVH260-347SS V
3 32 T8 3/4 55/1397 120-277 FVR332BU
3 32 T8 3/4 55/1397 347 FVR332-347S0 V

Note: BU ballasts are auto-sensing, solid state for any voltage between 120 and 277 V, 50 or 60 Hz.
* Does not apply to fixtures with fusing.
① Consult factory for availability of specific voltages.
② 4’ fixture only.
③ 32 W SS Octron and F40BX only.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1071


© September 2010
FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations

Class I, Division 2, Groups A, B, C, D Marine Type Electric Fixture


Class I, Zone 2, Group IIC Outside Type (Salt Water) *
Class II Division 1, Groups E, F, G Type 4X
Class II, Division 2, Groups F, G Wet Locations

Catalog
Description Standard Materials Number
Surface Mount (set of 2) 14-gauge stainless steel FVSM

Adjustable Wall Mount (set of 2) Copperfree (4/10 of 1% max.) aluminum FVWAM

Fixed 45°˚ Wall Mount (set of 2) 11-gauge (1/8”) stainless steel FVWFM

Chain Mount (set of 2) Zinc plated steel M8 ring bolts (chain not provided) FVCM
Lighting

Technical Data — Thermal Performance of FV Series Fixtures


For supply connection, use wire rated 167 °F/75 °C.

Lamp Min. Start Ambient


Lamp Temp ˚ Temp. “T”
Fixture Quantity Watt Type Lumens (°C/°˚F) (°C/°˚F) Numbers
Lighting: Enclosed and Gasketed — Area — Fluorescent

FVP240BU 2 40 F40BX 3300 -18/0 55/131 T4


FVP240-347 V 2 40 F40BX 3300 -18/0 55/131 T4
FVP440BU 4 40 F40BX 3300 -18/0 55/131 T4
FVP440-347 V 4 40 F40BX 3300 -18/0 55/131 T4
FVR232BU 2 32 T8-RS 2850 -18/0 40/104 T6
FVR232-347S0 2 32 T8-RS 2850 -18/0 40/104 T6
FVH244-BU 2 44 T8-HO 4050 -10/14 40/104 T6
FVH244-347S0 V 2 44 T8-HO 4050 -10/14 40/104 T6
FVR240BU 2 40 T12-RS 3050 10/50 40/104 T5
FVR240-347SS V 2 40 T12-HO 3050 10/50 40/104 T5
FVH260BU 2 60 T12-HO 4050 -28/-20 40/104 T4A
FVH260-347SS V 2 60 T12-HO 4050 -28/-20 40/104 T4A
FVR332BU 3 32 T8-RS 2850 -18/0 40/104 T6

* Does not apply to fixtures with fusing.


V CSA Certification only.

1072 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FV™ Series Nonmetallic Fluorescent Luminaire Dimensions
For Hazardous and Adverse Locations

Dimensions
FV Series

0.6"/ A
15.24 mm
5.7"/
144.8 mm

8.6"/
218.4
mm

FVWFM FVWAM FVSM FVCM


Ø 0.31"/
8.0 mm
Ø 0.78"/
9.25”/ 19.8 mm
235.0 mm
0.70"/

m /
.9 4"
m
17.78 mm

23 0.9

3 "/
m
0.31"/ 0.59"/

6 "/

1. 50
m

m
m /
.5 8"

9. 5
m
15.0 mm

m
24 9.
2
7.87 mm

60 2.3

20 .8
9.21”/ 60° MAX.
233.9 mm 0.20"/ Ø 0.31"/8.0 mm
5.08 mm

9 "/
7.5”/

Lighting
4. 13
m
190.5 mm
9.5"/
241.3 mm 0.31"/ 10 4.
7.87 mm

7.64"/
194.1 mm 0.20"/
4.00”/ 5.08 mm
1.25"/ 101.6 mm
31.8 mm
0.38”/ 0.31"/
3.56"/ 9.5 mm 7.87 mm
m /
.4 0"
m
90.4 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent


25 1.0

7.72"/
0.31"/ 196.1 mm
7.9 mm
Dia.

0.25"/
6.3 mm Dia.

Mounting Centers and Overall Length


A B

2 FT./0.6 M 15.80”/401.3 mm 31.00”/787.4 mm


4 FT./1.2 M 27.60"/701.0 mm 55.00”/1397.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1073


© September 2010
FV™ Series Nonmetallic Fluorescent Luminaire Photometric Data
For Hazardous and Adverse Locations

CIE TYPE – DIRECT


PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA: 1.2 1.5 FVP 240, Two 40 W PL Lamps • Total Luminaire Efficiency = 92.7%
CANDELA DISTRIBUTION % Floors Rfc 20
ZONAL % Ceiling Rcc 80 70 50 30 10 0
0.0 45.0 90.0 LUMENS % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1705 1705 1705 0 1.10 1.10 1.10 1.10 1.08 1.08 1.08 1.08 1.03 1.03 1.03 .99 .99 .99 .95 .95 .95 .93
5 1701 1698 1687 161 1 .99 .93 .89 .84 .96 .91 .87 .83 .87 .83 .80 .83 .80 .78 .80 .78 .75 .73

Room Cavity Ratio


15 1635 1642 1688 468 2 .89 .80 .73 .67 .86 .78 .72 .66 .75 .69 .64 .72 .67 .63 .69 .65 .61 .59
25 1513 1581 1660 731 3 .80 .69 .61 .54 .78 .68 .60 .54 .65 .58 .53 .62 .57 .52 .60 .55 .51 .49
35 1324 1492 1623 932 4 .73 .61 .52 .45 .71 .60 .51 .44 .57 .50 .44 .55 .49 .44 .53 .48 .43 .41
45 1085 1361 1516 1027 5 .67 .54 .45 .39 .65 .53 .45 .38 .51 .44 .38 .49 .43 .37 .47 .42 .37 .35
55 806 1161 1292 992 6 .62 .49 .40 .33 .60 .48 .39 .33 .46 .38 .33 .44 .38 .33 .43 .37 .32 .30
65 490 888 1065 836 7 .57 .44 .35 .29 .55 .43 .35 .29 .42 .34 .29 .40 .34 .29 .39 .33 .28 .26
75 197 644 821 619 8 .53 .40 .32 .26 .52 .39 .31 .26 38 .31 .25 .37 .30 .25 .36 .30 .25 .23
85 32 360 497 351 9 .50 .37 .29 .23 .48 .36 .28 .23 .35 .28 .23 .34 .27 .23 .33 .27 .23 .21
90 12 257 399 10 .46 .34 .26 .21 .45 .33 .26 .21 .32 .25 .21 .31 .25 .21 .30 .24 .20 .19

CIE TYPE – DIRECT


PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA: 1.2 1.5 FVP 440, Four 40 W PL Lamps • Total Luminaire Efficiency = 85.8%
CANDELA DISTRIBUTION % Floors Rfc 20
ZONAL % Ceiling Rcc 80 70 50 30 10 0
0.0 45.0 90.0 LUMENS % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 3152 3152 3152 0 1.02 1.02 1.02 1.02 1.00 1.00 1.00 1.00 .95 .95 .95 .91 .91 .91 .88 .88 .88 .86
5 3139 3138 3130 299 1 .99 .93 .89 .84 .96 .91 .87 .83 .87 .83 .80 .83 .80 .78 .80 .78 .75 .73
Room Cavity Ratio

15 3030 3060 3036 868 2 .89 .80 .73 .67 .86 .78 .72 .66 .75 .69 .64 .72 .67 .63 .69 .65 .61 .59
25 2798 2910 3041 1351 3 .74 .64 .56 .50 .72 .63 .56 .50 .60 .54 .49 .58 .52 .48 .55 .51 .47 .45
35 2470 2740 2091 1720 4 .68 .56 .48 .42 .66 .55 .48 .42 .53 .46 .41 .51 .45 .40 .49 .44 .40 .38
45 2043 2517 2760 1897 5 .62 .50 .42 .36 .60 .49 .41 .35 .47 .40 .35 .46 .39 .35 .44 .39 .44 .32
55 1523 2130 2373 1827 6 .57 .45 .37 .31 .55 .44 .36 .31 .42 .36 .30 .41 .35 .30 .40 .34 .30 .28
Lighting

65 941 1656 1976 1553 7 .53 .41 .33 .27 .51 .40 .32 .27 .38 .32 .27 .37 .31 .26 .36 .30 .26 .24
75 378 1234 1532 1163 8 .49 .37 .29 .24 .48 .36 .29 .24 .35 .28 .24 .34 .28 .24 .33 .27 .23 .22
85 49 679 901 649 9 .46 .34 .26 .21 .45 .33 .26 .21 .32 .26 .21 .31 .25 .21 .30 .25 .21 .19
90 10 474 694 10 .43 .31 .24 .19 .42 .31 .24 .19 .30 .23 .19 .29 .23 .19 .28 .23 .19 1.75

CIE TYPE – DIRECT


PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA: 1.2 1.5 FVR 232, Two T8 32 W Lamps* • Total Luminaire Efficiency = 77.4%
CANDELA DISTRIBUTION % Floors Rfc 20
Lighting: Enclosed and Gasketed — Area — Fluorescent

ZONAL % Ceiling Rcc 80 70 50 30 10 0


0.0 45.0 90.0 LUMENS % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1101 1101 1101 0 .92 .92 .92 .92 .90 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77
5 1098 1098 1097 104 1 .81 .77 .72 .68 .79 .75 .71 .67 .71 .68 .65 .68 .66 .63 .65 .63 .61 .59
Room Cavity Ratio

15 1056 1069 1085 303 2 .73 .65 .59 .53 .71 .64 .58 .53 .61 .56 .51 .58 .54 .50 .56 .52 .49 .47
25 976 1026 1093 477 3 .65 .56 .49 .44 .63 .55 .49 .43 .53 .47 .43 .51 .46 .42 .49 .45 .41 .39
35 856 985 1096 616 4 .60 .49 .42 .36 .58 .48 .41 .35 .46 .40 .35 .44 .39 .34 .42 .38 .34 .32
45 710 928 1075 703 5 .55 .44 .37 .31 .53 .43 .36 .31 .41 .35 .31 .40 .34 .30 .38 .34 .30 .28
55 528 830 986 709 6 .50 .39 .31 .26 .49 .38 .31 .26 .35 .30 .26 .35 .30 .25 .34 .29 .25 .23
65 328 681 849 636 7 .47 .35 .28 .23 .45 .35 .28 .23 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20
75 132 567 757 530 8 .43 .32 .25 .20 .42 .31 .25 .20 .30 .24 .20 .29 .24 .20 .28 .23 .19 .18
85 14 340 499 332 9 .40 .29 .22 .18 .39 .29 .22 .18 .28 .22 .18 .27 .21 .18 .26 .21 .17 .16
90 4 252 397 10 .38 .27 .20 .16 .37 .26 .20 .16 .26 .20 .16 .25 .20 .16 .24 .19 .16 .14

CIE TYPE – DIRECT


PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA: 1.2 1.4 FVR 332, Three T8 32 W Lamps • Total Luminaire Efficiency = 75.7%
CANDELA DISTRIBUTION % Floors Rfc 20
ZONAL % Ceiling Rcc 80 70 50 30 10 0
0.0 45.0 90.0 LUMENS % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1780 1780 1780 169 0 .90 .90 .90 .90 .88 .88 .88 .88 .84 .84 .84 .81 .81 .81 .77 .77 .77 .76
5 1767 1773 1771 169 1 .80 .76 .72 .68 .78 .74 .70 .67 .71 .68 .65 .68 .65 .63 .65 .63 .61 .59
Room Cavity Ratio

15 1700 1732 1757 490 2 .72 .65 .59 .54 .70 .63 .58 .53 .61 .56 .52 .58 .54 .51 .56 .52 .50 .48
25 1574 1661 1734 767 3 .65 .56 .49 .44 .63 .55 .49 .43 .53 .47 .43 .51 .46 .42 .49 .45 .41 .39
35 1388 1554 1652 1064 4 .60 .50 .42 .37 .58 .48 .42 .36 .47 .41 .36 .45 .39 .35 .43 .38 .35 .33
45 1150 1388 1556 1064 5 .55 .44 .37 .31 .53 .43 .36 .31 .41 .35 .31 .40 .34 .30 .38 .34 .30 .28
55 860 12001 3671 038 6 .50 .39 .32 .27 .49 .39 .32 .27 .37 .31 .27 .36 .30 .26 .35 .30 .26 .24
65 53 6949 1116 881 7 .46 .36 .29 .24 .45 .35 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .21
75 214 698 914 675 8 .43 .32 .26 .21 .42 .32 .25 .21 .31 .25 .21 .30 .24 .21 .29 .24 .20 .19
85 21 443 637 426 9 .40 .30 .23 .19 .39 .29 .23 .19 .28 .23 .19 .27 .22 .18 .27 .22 .18 .17
90 7 319 491 10 .38 .27 .21 .17 .37 .27 .21 .17 .26 .21 .17 .25 .20 .17 .25 .20 .17 .15

1074 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

FR Series FZ Series FD Series


Wet Locations Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
IP65 when used with optional polycarbonate Class I, Zone 2, IIC Class I, Zone 2, IIC
lens AEx nA IIC T5 IP65
Ex nA IIC T5 IP65

Applications
• For use in locations where a high degree of corrosion
resistance is required.
• FR Series:
— For use in areas where high humidity or water vapor are
present
— Typical uses include meat- or food-processing plants, dairy
or drug plants, breweries, kitchens, chemical plants, car
washes, laundries and parking garages.
— Can be used indoors or outdoors in protected locations
(wet locations).
— Operates safely in 100 °F/38 °C ambient temperature areas.
• FZ and FD Series:
— For use in hazardous locations defined by the NEC as
Class I, Division 2; and Class I, Zone 2.
— For wet-location use where protection against dirt, water Illustrated Features
and moisture is necessary.
— Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food-processing plants, Non-thixotropic polyol gasket is
warehouses, underground tunnels and general bonded to housing. With plastic
manufacturing facilities. latches closed, it forms a continu-
• FZ Series is UL Listed for Class I, Division 2 and Zone 2. ous, tight seal with lens. Keeps out
• FD Series fixture is UL listed for Class I, Division 2. moisture, vapor and dirt. Allows fast,
Features easy fixture washing.
• Fixtures are available with ballasts to support T12 and T8
lamps for nearly all U.S. and foreign voltage and frequency • Chain mount: zinc plated steel
combinations. • Gasket: non-thixotropic polyol

Lighting
• Low operating costs provide more lumens per Watt than • Hubs: zinc plated steel with neoprene o-ring
incandescent fixtures. • Lampholders: polycarbonate
• Housing is smooth, seamless, one-piece injection molded.
• Lens comes in high-impact polycarbonate plastic or impact- Standard Finishes
resistant acrylic. • Housing: white color finish
• Fixtures are washable, non-conductive and corrosion-resistant. • Celcon latches: white color finish
• Enclosure is rated at IP65 (using polycarbonate lens), dust-proof • Adjustable wall mount: epoxy powder coat
and protected against water spray.
Options:

Lighting: Enclosed and Gasketed — Area — Fluorescent


• A compressible, one-piece, non-thixotropic polyol gasket
is bonded to the housing around the entire perimeter. It • F - Fused
forms a continuous tight seal with the lens to keep out dirt, • T - Terminal Blocks
vapor and moisture. • P - Polycarbonate Lens for IP65 Rating
• Lens is securely clamped to fixture using six captive • E - Emergency Battery Pack capability in moments of power
corrosion-proof molded celcon tension latches. Lens is interruption. Luminiare automatically switches to emergency
impact-resistant acrylic to protect lamps against breakage, mode, keeping one lamp illuminated for a minimum of 90
and protect work area from broken lamp glass. minutes. When AC power is restored, battery automatically
• Electrical components are mounted on a metallic wireway. recharges in 24 hours. Initial light output is 600-700 lumens.
Reflector is supported by internal safety springs to simplify Compliancies and Certifications
installation and servicing.
• Optional fusing protects circuitry against occasional line voltage • FR Series:
spikes. — UL Standard: UL 1598
• FR Series fixtures are available with one or two watertight 1/2” — UL Listed: E187946
hubs for electrical-feed mounting or single-entry mounting. — CSA Standard: C22.2 No. 250
• FZ fixtures are available with either 1/2” NPT or cable gland — cUL Listed: E187946
entries. • FZ Series:
— Cable glands are not available with FD series. — UL Standard: UL 1598, UL 844, UL 60079-0, UL 60079-15
— UL Listed: E10794
Standard Materials — CSA Standard: C22.2 No. 250, C22.2 No. 137,
• Housing: fiberglass reinforced polyester CAN E60079-0, CAN E60079-15
• Lens: polycarbonate or acrylic. (Fixture has IP65 rating with — cUL Listed: E10794
polycarbonate lens.) Acrylic lens supplied as standard • FD Series:
• Latches: celcon — UL Standard: UL 1598, UL 844
• Ceiling mounting bracket: stainless steel — UL Listed: E10794
• Adjustable wall mount: copperfree (4/10 of 1% max.) aluminum — CSA Standard: C22.2 No. 250, C22.2 No. 137
• Fixed wall mount: stainless steel — cUL Listed: E10794

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1075


© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

FR Series FZ Series FD Series


Wet Locations Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
IP65 when used with optional polycarbonate Class I, Zone 2, IIC Class I, Zone 2, IIC
lens AEx nA IIC T5 IP65
Ex nA IIC T5 IP65

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FR, FZ And FD Nonmetallic Fluorescent Lighting Fixtures
FZ N1 C 2 4 08 S 126 2 F

Series: Number of Lamps: Ballast Type: Number of Ballasts:


FR - Wet 2 - 2 Lamps S - Solid State ② Blank - Single
Location 2 - Double
FZ - Zone 2,
AEx nA, Ex
nA
FD - Class I,
Division 2 ①

Conduit/Cable Lamp Length: Voltage:


Entry: 4 - 4 Feet 347 - 347 V, 60 Hz V
N1 - 1/2” NPT BU - 120-277 V,
Conduit Single 50/60 Hz
Entry (0 °F/-18 °C
M1 - Cable Gland start)
Single Entry
⑤⑦
N2 - 1/2” NPT
Conduit (2 hubs
provided)
M2 - Cable Gland
Feed Thru ⑥⑦
Lighting

Mounting Lamp Type: Options:


Configuration: 08 - T8, 32 W, 265MA F - Fused ⑧
C - Ceiling 12 - T12, 40 W, 430MA T - Terminal Blocks ④
P - Pendant P - Polycarbonate
lens ③ for IP65
EL- Emergency
Battery Pack
Lighting: Enclosed and Gasketed — Area — Fluorescent

① Fixture is not available with M1 or M2 cable entry options


② Cold weather standard for T8.
③ Use polycarbonate lens for IP65 rating. Polycarbonate lens is standard on FZ Series.
④ Standard equipment for FZ series
⑤ Fixture will be supplied with a 5’/1.5 m length of #14/3 cord and 3 prong plug (120 V) pre-installed when ordered with cable gland. Fixture with cable gland
can only be used with hook and chain mounting.
⑥ ???.
⑦ FZ Series fixtures are not UL Listed for Class I, Division 2 when used with cable glands. FZ Series fixtures are UL Classified for Class I, Zone 2 when used
with cable glands.
⑧ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification only.

1076 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Accessories and Replacement Parts
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

Item Description Catalog Number


Hub
1/2” NPT watertight conduit hub FHUB

Cable Gland
Cable gland FGLAND

Lampholder

32 W (T8) and 40 W (T12) lampholder FS0C40

Lens Clip
Standard plastic clips FPCLIP

Lighting
Lens
Acrylic lens cover FLENS

Polycarbonate lens cover ① FPLENS


Ceiling Mounting Bracket (Supplied standard with product)

Lighting: Enclosed and Gasketed — Area — Fluorescent


Stainless steel bracket with mounting hardware (set of 2) FBRACKET

Fixed 45° Wall Mount


11 gauge (1/8”) stainless steel (set of 2) FVWFM

① Polycarbonate lens standard for FZ series. When used with FD series, fixture has an IP65 rating.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1077


© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Dimensions
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

View of Fixture Cover

8.25”/209.6 mm

165.1 mm
6.50”/
38.75"/ 984.3 mm
50.00”/ 1270 mm

Side View Fixed 45° Wall Mount — FVWFM


7.44"/
7 -41/9
189.0 mm4”
1.25"/
1-1/4”
31.8 mm

7-23/32”
196.1 mm
7.72"/
90.4 mm
3-9/16”
3.56"/
0.31"/
5.50"/ 5/16”
7.9 mm
139.7 mm DIA.
Dia.
Lighting

1.50"/
1/4”
0.25"/
38.1mm DIA.
6.35 mm
Dia.
3.25"/
82.6 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent

View of Fixture Mounting

1078 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Photometric Data
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 84.6%


REPORT NUMBER: ITL 47240
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 1155 1155 1155 1155 1155 Plane: 0˚ 90˚ Lamps: Two 32 W, 4-foot F32T8/TL735 fluorescents,
5 1159 1153 1150 1148 1148 110 Spacing Criteria: 1.3 1.5 2850 lumens per lamp with acrylic lens.
15 1118 1118 1124 1134 1137 318 Shielding Angles: 1 0
25 1036 1049 1071 1109 1125 498
35 918 945 1010 1087 1114 636
45 766 812 927 1026 1056 710 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
55 569 652 788 900 927 690 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
65 342 450 598 719 753 574 % Ceiling RC 80 70 50 30 10 0
75 148 259 432 567 604 434 90˚ % Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
85 25 133 318 444 473 312 ZONAL LUMEN 0 .98 .98 .98 .98 .95 .95 .95 .95 .89 .89 .89 .83 .83 .83 .78 .78 .78 .75
75˚
90 4 98 270 376 412 SUMMARY 1 .88 .83 .78 .74 .84 .80 .76 .72 .75 .71 .68 .70 .67 .65 .65 .63 .61 .58
400
95 5 84 258 372 414 249 ZONE LUMENS 60˚ 2 .79 .71 .65 .59 .76 .69 .63 .58 .64 .59 .55 .60 .56 .52 .56 .52 .50 .47
105 2 42 182 292 341 181 0- 30 926 3 .71 .62 .54 .48 .68 .60 .53 .47 .56 .50 .45 .52 .47 .43 .49 .45 .41 .39
115 0 13 69 139 182 79 0- 40 1562 800 4 .65 .54 .46 .40 .62 .52 .45 .39 .49 .43 .38 .46 .41 .36 .43 .38 .35 .32
45˚
125 0 3 22 36 50 21 0- 60 2962 5 .60 .48 .40 .34 .57 .47 .39 .33 .44 .37 .32 .41 .35 .31 .38 .34 .30 .28
135 0 0 9 15 19 7 0- 90 4282 1200
6 .55 .43 .35 .29 .53 .52 .34 .29 .39 .33 .28 .37 .31 .27 .35 .30 .26 .24
145 0 0 2 7 9 2 90-120 509 0˚ 15˚ 30˚ 7 .51 .39 .31 .26 .49 .38 .30 .25 .36 .29 .24 .33 .28 .24 .32 .27 .23 .21
155 0 0 0 0 2 0 90-130 529 Legend 8 .47 .35 .28 .23 .45 .34 .27 .22 .32 .26 .22 .31 .25 .21 .29 .24 .20 .19
165 0 0 0 0 0 0 90-150 538 0-deg 9 .44 .32 .25 .20 .42 .31 .25 .20 .30 .24 .19 .28 .23 .19 .27 .22 .18 .17

Lighting
45-deg
175 0 0 0 0 0 0 90-180 539 90-deg 10 .41 .30 .23 .18 .40 .29 .22 .18 .27 .22 .17 .26 .21 .17 .25 .20 .16 .15
180 0 0 0 0 0 0-180 4820

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 83.6%


REPORT NUMBER: ITL 47241
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 566 566 566 566 566 Plane: 0˚ 90˚ Lamps: Two 32 W, 4-foot F32T8/TL735 fluorescents,

Lighting: Enclosed and Gasketed — Area — Fluorescent


5 568 565 564 563 563 54 Spacing Criteria: 1.3 1.5 2850 lumens per lamp with polycarbonate lens.
15 548 549 550 554 555 156 Shielding Angles: 1 0
25 506 512 523 543 552 243
35 448 461 495 535 549 312
45 374 396 458 509 525 350
55 283 324 399 457 475 349 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
65 177 241 318 393 409 306 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
75 72 142 211 259 267 210 90˚ % Ceiling RC 80 70 50 30 10 0
85 6 63 150 212 228 146 ZONAL LUMEN % Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75˚
90 1 46 118 167 186 SUMMARY 0 .97 .97 .97 .97 .94 .94 .94 .94 .88 .88 .88 .82 .82 .82 .77 77 77 .75
190
95 1 43 122 176 198 118 ZONE LUMENS 60˚ 1 .87 .82 .78 .74 .84 .79 .75 .72 .74 .71 .68 .69 .67 .64 .65 .63 .61 .58
105 0 20 84 131 154 83 0- 30 453 2 .78 .70 .64 .58 .75 .68 .62 .57 .63 .59 .54 .59 .55 .52 .55 .52 .49 .47
380
115 0 5 33 74 92 40 0- 40 765 3 .71 .61 .53 .48 .68 .59 .52 .47 .55 .49 .45 .52 .47 .43 .48 .44 .41 .38
45˚
125 0 1 10 18 24 10 0- 60 1464 4 .64. 54 .46 .40 .62 .52 .44 .39 .48 .42 .37 .45 .40 .36 .43 .38 .34 .32
135 0 0 5 9 10 4 0- 90 2126 570 5 .59 .47 .39 .34 .56 .46 .39 .33 .43 .37 .32 .40 .35 .31 .38 .33 .29 .27
145 0 0 1 4 5 1 90-120 241 0˚ 15˚ 30˚ 6 .54 .42 .35 .29 .52 .41 .34 .28 .39 .32 .27 .36 .31 .27 .34 .29 .26 .24
155 0 0 0 1 1 0 90-130 251 Legend 7 .50 .38 .31 .25 .48 .37 .30 .25 .35 .29 .24 .33 .27 .23 .31 .26 .22 .21
165 0 0 0 0 0 0 90-150 256 0-deg 8 .46 .35 .27 .22 .45 .34 .27 .22 .32 .26 .21 .30 .25 .21 .28 .24 .20 .18
45-deg
175 0 0 0 0 0 0 90-180 256 90-deg 9 .43 .32 .25 .20 .42 .31 .24 .20 .29 .23 .19 .28 .22 .18 .26 .21 .18 .16
180 0 0 0 0 0 0-180 2383 10 .41 .29 .22 .18 .39 .28 .22 .18 .27 .21 .17 .26 .20 .17 .24 .20 .16 .15

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1079


© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Photometric Data
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 80.7%


REPORT NUMBER: ITL 47242
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 1224 1224 1224 1224 1224 Plane: 0˚ 90˚ Lamps: Two 40 W, 4-foot F40WW fluorescents,
5 1228 1223 1221 1219 1218 116 Spacing Criteria: 1.3 1.5 3150 lumens per lamp with acrylic lens.
15 1185 1190 1204 1219 1222 341 Shielding Angles: 1 0
25 1097 1122 1158 1200 1214 535
35 974 1020 1090 1166 1192 683
45 811 881 993 1094 1122 759
55 600 701 837 943 967 729 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
65 358 476 625 736 761 595 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
75 154 271 443 566 600 441 90˚ % Ceiling RC 80 70 50 30 10 0
85 25 136 325 455 490 321 ZONAL LUMEN % Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75˚
90 5 101 285 401 442 SUMMARY 0 .94 .94 .94 .94 .91 .91 .91 .91 .85 .85 .85 .79 .79 .79 .74 .74 .74 .72
450
95 5 84 260 372 415 253 ZONE LUMENS 60˚ 1 .84 .79 .75 .71 .81 .76 .73 .69 .71 .68 .65 .67 .64 .62 .62 .60 .58 .56
105 2 45 187 294 343 184 0- 30 992 2 .76 .68 .62 .57 .72 .66 .60 .55 .61 .57 .53 .57 .53 .50 .54 .50 .48 .45
900
115 0 14 85 163 204 91 0- 40 1676 3 .68 .59 .52 .46 .66 .57 .51 .45 .53 .48 .43 .50 .45 .41 .47 .43 .40 .37
45˚
125 0 3 23 53 81 28 0- 60 3164 4 .62 .52 .44 .39 .60 .50 .43 .38 .47 .41 .36 .44 .39 .35 .41 .37 .33 .31
135 0 0 9 16 20 7 0- 90 4521 1350 5 .57 .46 .39 .33 .55 .45 .38 .32 .42 .36 .31 .39 .34 .30 .37 .32 .29 .27
145 0 0 0 5 7 2 90-120 528 0˚ 15˚ 30˚ 6 .53 .41 .34 .28 .50 .40 .33 .28 .38 .32 .27 .35 .30 .26 .33 .29 .25 .23
155 0 0 0 0 0 0 90-130 556 Legend 7 .49 .37 .30 .25 .47 .36 .29 .24 .34 .28 .24 .32 .27 .23 .30 .26 .22 .20
165 0 0 0 0 0 0 90-150 564 0-deg 8 .45 .34 .27 .22 .43 .33 .26 .22 .31 .25 .21 .29 .24 .20 .28 .23 .20 .18
Lighting

45-deg
175 0 0 0 0 0 0 90-180 564 90-deg 9 .42 .31 .24 .20 .40 .30 .24 .19 .29 .23 .19 .27 .22 .18 .26 .21 .18 .16
180 0 0 0 0 0 0-180 5085 10 .39 .28 .22 .18 .38 .28 .22 .17 .26 .21 .17 .25 .20 .16 .24 .19 .16 .14

Candela Distribution TOTAL LUMINAIRE EFFICIENCY = 78.9%


REPORT NUMBER: ITL 47243
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 1188 1188 1188 1188 1188 Plane: 0˚ 90˚ Lamps: Two 40 W, 4-foot F40WW fluorescents,
Lighting: Enclosed and Gasketed — Area — Fluorescent

5 1188 1186 1186 1184 1183 113 Spacing Criteria: 1.3 1.5 3150 lumens per lamp with polycarbonate lens.
15 1146 1155 1165 1177 1181 330 Shielding Angles: 1 0
25 1060 1085 1122 1165 1178 519
35 940 984 1055 1135 1161 663
45 782 850 970 1073 1102 738
55 589 687 836 950 977 725 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
65 367 500 652 765 791 618 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
75 145 293 437 548 563 431 90˚ % Ceiling RC 80 70 50 30 10 0
85 12 132 306 428 464 302 ZONAL LUMEN % Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
75˚
90 4 106 270 381 421 SUMMARY 0 .92 .92 .92 .92 .89 .89 .89 .89 .83 .83 .83 .78 .78 .78 .73 .73 .73 .70
400
95 5 86 244 348 389 240 ZONE LUMENS 60˚ 1 .82 .78 .74 .70 .79 .75 .71 .68 .70 .67 .64 .65 .63 .61 .61 .59 .57 .55
105 2 42 178 278 321 172 0- 30 961 2 .74 .67 .61 .55 .71 .64 .59 .54 .60 .55 .52 .56 .52 .49 .53 .49 .47 .44
800
115 0 8 82 163 201 88 0- 40 1624 3 .67 .58 .51 .45 .64 .56 .49 .44 .52 .47 .42 .49 .44 .41 .46 .42 .39 .37
45˚
125 0 1 19 54 82 27 0- 60 3087 4 .61 .51 .43 .38 .58 .49 .42 .37 .46 .40 .35 .43 .38 .34 .40 .36 .33 .31
135 0 0 8 16 18 6 0- 90 4438 1200 5 .56 .45 .38 .32 .53 .44 .37 .31 .41 .35 .30 .38 .33 .29 .36 .32 .28 .26
145 0 0 1 5 8 2 90-120 500 0˚ 15˚ 30˚ 6 .51 .40 .33 .28 .49 .39 .32 .27 .37 .31 .26 .35 .29 .25 .33 .28 .24 .23
155 0 0 0 0 0 0 90-130 527 Legend 7 .47 .36 .29 .24 .46 .35 .29 .24 .33 .27 .23 .31 .26 .22 .30 .25 .21 .20
165 0 0 0 0 0 0 90-150 535 0-deg 8 .44 .33 .26 .21 .42 .32 .26 .21 .30 .25 .20 .29 .23 .20 .27 .23 .19 .17
45-deg
175 0 0 0 0 0 0 90-180 535 90-deg 9 .41 .30 .24 .19 .39 .29 .23 .19 .28 .22 .18 .26 .21 .18 .25 .20 .17 .16
180 0 0 0 0 0 0-180 4973 10 .38 .28 .21 .17 .37 .27 .21 .17 .26 .20 .16 .24 .19 .16 .23 .19 .15 .14

1080 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Applications
• Can be installed in hazardous areas designated as Zone 1, 2, 21
and 22.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor/outdoor use where protection against dirt, water and
moisture is necessary. 2 x 58 W
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general manufacturing
facilities.
Features
• Corrosion-resistant fiberglass reinforced polyester body and
hinged polycarbonate lens. 2 x 36 W
• High impact resistance housing (20 Joules – IK10) from -40 °F to
131 °F / -40 °C to 55 °C ambient temperature and wind profile
for use in extreme offshore and onshore environments.
• Latch assembly and elastomer gasket seals against water and
dust ingress, IP66/67.
• Easily accessed for maintenance using Allen key or straight
blade screwdriver.
• Central opening with unique patented release system to prevent 2 x 18 W
damage.
• Hinged parabolic reflector for high lumen output efficiency.
• Vibration resistant spring loaded lampholders for bi-pin (G13) or
mono-pin (Fa6) versions. EOL
Approved
• Positive safety switch disconnects power to lamps and ballast

Lighting
to allow maintenance in hazardous locations.
• Electronic multi-tap ballast 110 to 254 Vac/Vdc +/- 10% 50/60
Hz, for global applications. High power factor electronic ballast Certifications and Compliances
(>0.95). EOL (End Of Life) protection in accordance to the latest • Certification Type: FLe
EN/IEC 60079-7 standard. • Zones 1 and 2
• Two channel ballast prevents dark areas by allowing one lamp to — Conforming to ATEX 94/9/CE: CE 0081 II 2 G
remain lit if one fails. — ATEX/IEC Protection: Ex de IIC or Ex demb IIC
• Ballast plug-in with Ex e connector for quick and error-free (emergency version)

Lighting: Enclosed and Gasketed — Area — Fluorescent


maintenance. — T Rating: T5 ① to T4
• Available in 3 hours emergency version, including multi-tap • Zone 21 and 22
ballast with built-in monthly self test. Test results through multi- — Conforming to ATEX 94/9/CE: CE 0081 II 2 D
colored LED. — ATEX/IEC Protection: Ex tD A21
• Ex e battery with plug-in connector for maintenance in — Surface Temperature: 167 °F/75 °C
hazardous location. • Ambient Temperature: -40 °F to 131 °F / -40 °C to 55 °C
Standard Materials • CE Declaration of Conformity: 50201
• ATEX Certificate: LCIE 07 ATEX 6017
• Fiberglass reinforced polyester housing • IECEx Certificate: LCIE Ex 04.0017
• Polycarbonate lens • Other Certifications: GOST, Marine Listed UL 1598A
• Elastomer gasket • Index of Protection (solid & liquid): IP66/67
• Highly reflective white polycarbonate internal reflector • Impact Resistance (shock): IK10
• Mounting accessories available in different materials such as • Ex Standards: EN / IEC 60079-0; 60079-1; 60079-7; 60079-18;
gray painted aluminum, zinc plated steel, galvanized steel or 61241-0; 61241-1
316 stainless steel • Product Standards: EN / IEC 60598-1; 60598-2-22
Options • EMC Standards: EN / IEC 55015; 61547
• Silicone coating for added protection in H2S hydrogen sulfide • Other Standards: EN / IEC 60529 (IP); 62262 (IK)
environments.
• Without safety switch.
• Level gauge light fitting.
• 316 stainless steel fixing inserts.

① With ceiling position use at 104 °F/40 °C ambient temperature

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1081


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Illustrated Features

Can be mounted horizontally or vertically

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FE Nonmetallic Fluorescent Lighting Fixtures
FE B 1 18 BU P A C

Series: Wattage: Cable Type:


FE - FE Series 18 - 18 Watt A - Armored M20
Zone 1, 2, 21, 22 36 - 36 Watt N - Unarmored M25
ATEX / IEC Certified 58 - 58 Watt U - Unarmored M20
Lighting

Lamp Type: Voltage: Cable Type:


B - Bi-pin (G13) BU - 110 to 254 Vac/Vdc A - Armored M20
M - Mono Pin (Fa6) 50/60 Hz N - Unarmored M25
BK - 220 to 240 Vac/Vdc U - Unarmored M20
50/60 Hz
Lighting: Enclosed and Gasketed — Area — Fluorescent

Number of Lamps: Mounting Version:


1 - Single P - Pole Mount ①
2 - Double S - Surface/Suspension Mount
3 - Three Lamps Standard Wiring
T - Surface/Suspension Mount
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)

① Only 2 x 18 W and 2 x 36 W with M25 entry versions.


② Only 36 W and 58 W emergency versions.
③ Only for single standard versions.
④ Only for standard versions.
⑤ Only for S, T and L mounting versions.

1082 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Standard Wiring Version


Connection via 1 x 6 terminals.
Capacity (flexible/solid): 4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13)


Three M25 threaded entries, two at one end and one at opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
1 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB118BUSN
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB218BUSN
1 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB136BUSN
2 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB236BUSN
3 36 G13 110/254 21.83/9.9 3307.49/54.2 FEB336BUSN
1 58 G13 110/254 19.84/9 3966.54/65 FEB158BUSN
2 58 G13 110/254 19.84/9 3966.54/65 FEB258BUSN
3 58 G13 110/254 24.3/11 3966.54/65 FEB358BUSN
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number Power Lamp Voltage Weight Volume Catalog

Lighting
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
1 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB118BUSA
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB218BUSA
1 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB136BUSA
2 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB236BUSA

Lighting: Enclosed and Gasketed — Area — Fluorescent


3 36 G13 110/254 21.83/9.9 3307.49/54.2 FEB336BUSA
1 58 G13 110/254 19.84/9 3966.54/65 FEB158BUSA
2 58 G13 110/254 19.84/9 3966.54/65 FEB258BUSA
3 58 G13 110/254 24.3/11 3966.54/65 FEB358BUSA
Unarmored Version - Mono-pin (Fa6)
Three M25 threaded entries, two at one end and one at opposite end, supplied with
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 Fa6 110/254 12.13/5.5 1971.07/32.3 FEM218BUSN
2 36 Fa6 110/254 17.42/7.9 3307.49/54.2 FEM236BUSN
2 58 Fa6 110/254 19.84/9 3966.54/65 FEM258BUSN
Armored Version - Mono-pin (Fa6)
Two M20 threaded entries with brass earth continuity plate at one end and one M20
plugged clearance entry supplied with two M20 polyamide plugs.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 Fa6 110/254 12.13/5.5 1971.07/32.3 FEM218BUSA
2 36 Fa6 110/254 17.42/7.9 3307.49/54.2 FEM236BUSA
2 58 Fa6 110/254 19.84/9 3966.54/65 FEM258BUSA

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1083


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Through Wiring Version (three phase)


Connection via 2 x 5 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13)


Three M25 threaded entries, two at one end and one at opposite end, supplied with two M25 polyamide cable
gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and one M25 polyamide plug.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB218BUTN
2 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB236BUTN
2 58 G13 110/254 19.84/9 3966.54/65 FEB258BUTN
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded
entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.

Number Power Lamp Voltage Weight Volume Catalog


of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB218BUTA
2 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB236BUTA
2 58 G13 110/254 19.84/9 3966.54/65 FEB258BUTA
Lighting

Surface/Suspension Mounting and Dual Loop In/Out Through


Wiring Version (single phase):
Connection via 1 x 6 terminals and 1 x 3 terminals.
Capacity (flexible/solid): 0.006in2/0.009in2 / 4 mm2/6 mm2.
Lighting: Enclosed and Gasketed — Area — Fluorescent

Unarmored Version - Bi-pin (G13)


Three M25 entries, two at one end and one at opposite end, supplied with two M25 polyamide cable glands
(dia. 8 to 18.5 mm) and one M25 polyamide plug.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB218BULN
2 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB236BULN
2 58 G13 110/254 19.84/9 3966.54/65 FEB258BULN

Armored Version - Bi-pin (G13)


Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded
entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB218BULA
2 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB236BULA
2 58 G13 110/254 19.84/9 3966.54/65 FEB258BULA

1084 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Pole Mounting Version


Connection via 1 x 3 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.
For mounting on dia. 1.65"/42 mm pole or tubular wall-mounting support,
supplied with one integrated M25 polyamide cable gland
(dia. 0.31 to 0.73" / 8 to 18.5 mm).

Number Power Lamp Voltage Weight Volume Catalog


of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 G13 110/254 13.67/6.2 2080.91/34.1 FEB218BUPN
2 36 G13 110/254 19.18/8.7 3307.49/54.2 FEB236BUPN

Level Gauge Tank Light -


Surface/Suspension Mounting with Standard Wiring
Connection via 1 x 6 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13)


Three M25 entries, two at one end and one at opposite end, supplied with
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number

Lighting
1 18 G13 110/254 12.13/5.5 1971.07/32.3 FEB118BUSNL
1 36 G13 110/254 17.42/7.9 3307.49/54.2 FEB136BUSNL
1 58 G13 110/254 19.84/9 3966.54/65 FEB158BUSNL

Lighting: Enclosed and Gasketed — Area — Fluorescent

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1085


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Standard Wiring


Connection via 1 x 4 terminals for 18 W version.
Connection via 1 x 8 terminals for
36 W & 58 W versions.
Capacity (flexible/solid): 0.006 in2/0.009 in2 /
4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13)


Three M25 entries, two at one end and one at
opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" /
8 to 18.5 mm) and two M25 polyamide plugs.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 G13 110/254 16.09/7.3 1971.07/32.3 3H 4Ah FEB218BUSNE
2 36 G13 110/254 21.16/9.6 3307.49/54.2 3H 4Ah FEB236BUSNE
2 36 G13 110/254 21.16/9.6 3307.49/54.2 3H 7Ah FEB236BUSNE7
3 36 G13 110/254 25.57/11.6 3307.49/54.2 3H 4Ah FEB336BUSNE
2 58 G13 110/254 23.59/10.7 3966.54/65 3H 4Ah FEB258BUSNE
2 58 G13 110/254 23.59/10.7 3966.54/65 3H 7Ah FEB258BUSNE7
3 58 G13 110/254 28.00/12.7 3966.54/65 3H 4Ah FEB358BUSNE
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one
M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
Lighting

of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number


2 18 G13 110/254 16.09/7.3 1971.07/32.3 3H 4 Ah FEB218BUSAE
2 36 G13 110/254 21.16/9.6 3307.49/54.2 3H 4 Ah FEB236BUSAE
2 36 G13 110/254 21.16/9.6 3307.49/54.2 3H 7 Ah FEB236BUSAE7
3 36 G13 110/254 25.57/11.6 3307.49/54.2 3H 4 Ah FEB336BUSAE
2 58 G13 110/254 23.59/10.7 3966.54/65 3H 4 Ah FEB258BUSAE
Lighting: Enclosed and Gasketed — Area — Fluorescent

2 58 G13 110/254 23.59/10.7 3966.54/65 3H 7 Ah FEB258BUSAE7


3 58 G13 110/254 28.00/12.7 3966.54/65 3H 4 Ah FEB358BUSAE
Unarmored Version - Mono-pin (Fa6)
Three M25 entries, two at one end and one at opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 Fa6 110/254 16.76/7.6 1971.07/32.3 3H 4 Ah FEM218BUSNE
2 36 Fa6 110/254 21.83/9.9 3307.49/54.2 3H 4 Ah FEM236BUSNE
2 36 Fa6 110/254 21.83/9.9 3307.49/54.2 3H 7 Ah FEM236BUSNE7
2 58 Fa6 110/254 24.25/11 3966.54/65 3H 4 Ah FEM258BUSNE
2 58 Fa6 110/254 24.25/11 3966.54/65 3H 7 Ah FEM258BUSNE7
Armored Version - Mono-pin (Fa6)
Two M20 threaded entries with brass earth continuity plate at one end and one
M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 Fa6 110/254 16.76/7.6 1971.07/32.3 3H 4 Ah FEM218BUSAE
2 36 Fa6 110/254 21.83/9.9 3307.49/54.2 3H 4 Ah FEM236BUSAE
2 36 Fa6 110/254 21.83/9.9 3307.49/54.2 3H 7 Ah FEM236BUSAE7
2 58 Fa6 110/254 24.25/11 3966.54/65 3H 4 Ah FEM258BUSAE
2 58 Fa6 110/254 24.25/11 3966.54/65 3H 7 Ah FEM258BUSAE7

1086 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Through Wiring Version


Connection via 2 x 4 terminals.
Capacity (flexible/solid):0.006 in2/0.009 in2 / 4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13):


Three M25 entries, two at one end and one at opposite end, supplied
with two M25 polyamide cable glands (dia. 0.31 to 0.73" / 8 to 18.5 mm)
and one M25 polyamide plug.

Number Power Lamp Voltage Weight Volume Duration Battery Catalog


of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 Bi-pin 110/254 16.09/7.3 1971.07/32.3 3H 4 Ah FEB218BUTNE
2 36 Bi-pin 110/254 21.16/9.6 3307.49/54.2 3H 4 Ah FEB236BUTNE
2 36 Bi-pin 110/254 21.16/9.6 3307.49/54.2 3H 7 Ah FEB236BUTNE7
2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 4 Ah FEB258BUTNE
2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 7 Ah FEB258BUTNE7
Armored Version - Bi-pin (G13):
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded entry with brass earth continuity plate
at opposite end, supplied with one M20 polymaide plug.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 Bi-pin 110/254 16.09/7.3 1971.07/32.3 3H 4 Ah FEB218BUTAE
2 36 Bi-pin 110/254 21.16/9.6 3307.49/54.2 3H 4 Ah FEB236BUTAE

Lighting
2 36 Bi-pin 110/254 21.16/9.6 3307.49/54.2 3H 7 Ah FEB236BUTAE7
2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 4 Ah FEB258BUTAE
2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 7 Ah FEB258BUTAE7

Lighting: Enclosed and Gasketed — Area — Fluorescent

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1087


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Dual Loop


In/Out Through Wiring Version (single phase)
Connection via 1 x 4 double deck terminals for
18 W version.
Connection via 1 x 8 terminals and 1 x 4 or
terminals for 36 W & 58 W versions.
Capacity (flexible/solid): 0.006 in2/0.009 in2 /
4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13) 18 W 36/58 W


Three M25 entries, two at one end and one
at opposite end, supplied with two M25
polyamide cable glands (dia. 0.31 to 0.73" /
8 to 18.5 mm) and one M25 polyamide plug.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 Bi-pin 110/254 16.76/7.6 1971.07/32.3 3H 4 Ah FEB218BULNE
2 36 Bi-pin 110/254 21.83/9.9 3307.49/54.2 3H 4 Ah FEB236BULNE
2 36 Bi-pin 110/254 21.83/9.9 3307.49/54.2 3H 7 Ah FEB236BULNE7
2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 4 Ah FEB258BULNE
2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 7 Ah FEB258BULNE7

Armored Version - Bi-pin (G13)


Two M20 threaded entries with brass earth continuity plate at one end and one M20
Lighting

threaded entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 Bi-pin 110/254 16.76/7.6 1971.07/32.3 3H 4 Ah FEB218BULAE
2 36 Bi-pin 110/254 21.83/9.9 3307.49/54.2 3H 4 Ah FEB236BULAE
Lighting: Enclosed and Gasketed — Area — Fluorescent

2 36 Bi-pin 110/254 21.83/9.9 3307.49/54.2 3H 7 Ah FEB236BULAE7


2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 4 Ah FEB258BULAE
2 58 Bi-pin 110/254 23.59/10.7 3966.54/65 3H 7 Ah FEB258BULAE7

Pole Mounting Version


Connection via 1 x 4 terminals.
Capacity (flexible/solid): 4 mm2/6 mm2.

18 W - Actual Size 2'/0.6m 36 W - Actual Size 4'/1.2m


For mounting on dia. 42 mm pole or tubular wall-mounting support, supplied with
one x M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm).
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 Bi-pin 110/254 22.05/10 3307.49/54.2 3H 4 Ah FEB218BUPNE
2 36 Bi-pin 110/254 22.93/10.4 3307.49/54.2 3H 4 Ah FEB236BUPNE
2 36 Bi-pin 110/254 22.93/10.4 3307.49/54.2 3H 4 Ah FEB236BUPNE7

Note: 2 x 18 W is supplied with external battery pack (see dimensional data).

1088 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FE Series Nonmetallic Fluorescent Luminaires Accessories
Standard and Emergency Battery Back-Up. Increased Safety

Description Pack Catalog Number


Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel 1 FEFBZ
316 stainless steel 1 FEFBS

Brackets for Surface Mounting


Set of two
Aluminum (gray painted) 1 FESBA
316 stainless steel 1 FESBS
M8 Ring Bolts
Set of two
Zinc plated steel 1 FERBM8Z

Half Clamps Brackets for Pole Mounting


Set of two
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
Zinc plated steel 1 FEHC49Z
316 stainless steel 1 FEHC49S

Lighting
Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Zinc plated steel 1 FEHC60Z
316 stainless steel 1 FEHC60S
Wall Mounting Adaptor

Lighting: Enclosed and Gasketed — Area — Fluorescent


For pole mounting version (dia. 1.65"/42 mm)
Galvanized steel 1 FEWMG

Hinged Brackets
Set of two brackets for adjusting luminaire
Aluminum 1 FEHBA
316 stainless steel 1 FEHBS
Fall Prevention Kit
Safety chain retains fixture temporarily to ease installation
For M25 cable entry 1 FESCM25
For M20 cable entry 1 FESCM20
Adaptor for Fa8 Tube on Fa6 Lampholder
1 096905

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1089


© September 2010
FE Series Nonmetallic Fluorescent Luminaire Technical Data
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Wiring Diagram Emergency Function Diagram


Two Lamp Version
Mains
PE N L Mains Lighting Switch ON Lighting Switch OFF

Lighting
Switch ON

L’

U OFF
Standard Fluorescent
N Lighting Fixture
PE
Three Lamp Version

Mains Lighting Switch ON Lighting Switch OFF

U’ ON
U Emergency Fluorescent
N Lighting Fixture
PE

OFF
Lighting

LED Status
Color Indication Function
LED glows Batteries are connected
Lighting: Enclosed and Gasketed — Area — Fluorescent

Green
LED blinks Batteries are charged
Red LED blinks Batteries are not connected or defect
Yellow LED blinks Batteries are charging and discharging during automatic cycle

Emergency Light Duration


Version Battery Capacity Duration Light Output
2 x 18 W 4 Ah – 6 V 3 hours 45%
4 Ah – 6 V 3 hours 15%
2 x 36 W
7 Ah – 6 V 3 hours 25%
4 Ah – 6 V 3 hours 9%
2 x 58 W
7 Ah – 6 V 3 hours 15%

1090 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FE Series Nonmetallic Fluorescent Luminaire Dimensions
Standard and Emergency Battery Back-Up. Increased Safety

Dimensions in Inches/Millimeters
Surface/Suspension Mounting
18 Watt 36 Watt

15.75"/ 2 X MB 2 X MB
400.0 mm 27.56"/ 700.0 mm

30.91"/785.0 mm 54.72"/ 1390.0 mm

58 Watt End View

2 X MB
27.56"/ 700.0 mm
5.71"/
145.0 mm

8.54"/
217.0 mm
66.54"/ 1690.0 mm

Pole Mounting
18 Watt End View

Ø 1.65"/ 10.19"/
42.0 mm
258.8
258.8 mm

Lighting
5.71"/
145.0 mm

8.58”/
218.0 mm
1.99"/
50.0 mm 30.91"/ 785.0 mm

36 Watt

Lighting: Enclosed and Gasketed — Area — Fluorescent


1.99"/ 54.72"/ 1390.0 mm
50.0 mm

Emergency Pole Mounting


18 Watt End View

Ø 1.65"/ 10.19"/
42.0 mm 258.8 mm

3.58"/
91.0 mm 5.71"/
145.0 mm
4.72"/
1.99"/ 8.58”/
120.0 mm
50.0 mm 30.91"/ 785.0 mm 218.0 mm

39.37"/ 1000.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1091


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Set of two quick fixing brackets for ease of surface


mounting Zinc plated steel or stainless steel

0.35"/
9.0 mm

64 mm
2.52"/
0.16"/
9.0 mm

1.18"/
30 mm

8.5 mm
0.33"/
8.5
0.98"/ 25.0 mm
1.93"/ 49.0 mm

Set of two brackets for surface mounting.


Gray painted aluminum or stainless steel.
Lighting

9.13"/ 232 mm
7.87"/ 200 mm
38.0 mm
1.50"/
Lighting: Enclosed and Gasketed — Area — Fluorescent

13.0 mm
0.51"/

1.26"/
32.0 mm
mm
0.37"/
9.59.5

14.5
0.57"/ 14.5 mm

Set of two ring bolts.


Zinc plated steel.

0.79"/
20.0 mm

0.31"/
8.0 mm
15.0 mm 36.0 mm
0.59"/ 1.42"/

M 8 x 1.25

1092 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/67 – IK10

Set of two clamps for pole dia. 1.65”/42 mm to 2.36”/60 mm


(1-1/4" to 2"). Zinc plated steel or stainless steel.

95 for 1.25"/31.8 mm
or 1.50"/38.1mm

2.95”/
75.0 mm

0.55”/
14.0 mm or 84 for 2.00"/50.8mm
1.25"/31.8 mm
or 1.50"/38.1mm

”/
36
2. m
3.31”/ Ø 0m
85 mm 6

0.55”/
14.0 mm 2.00"/50.8mm

1.65”/42 mm dia. galvanized steel wall mounting pole.


5.98”/152.0 mm
5.04”/128.0 mm
0.47”/ Ø 0.79”/
12.0 mm 20.0 mm
42.0
1.65 m

Lighting
5.51”/140.0 mm
m
”/

0.20”/5.0 mm mm
/75.0
2.95”
m
0.0 m
2”/43
16.9

Lighting: Enclosed and Gasketed — Area — Fluorescent


Ø 0.41”/
10.5 mm

Set of two hinged brackets for adjusting luminaire.


Gray painted aluminum or stainless steel.
1.26”/
0.22”/ 32.0 mm
5.5 mm
3 0.71”/
82 .23
.0 ”/ 18.0 mm
mm
.0 /

mm
77 .03”
3

5.20”/132 mm

30°
100.0 mm
60
30

90

3.94”/

0.57”/
0

30
60
14.5 mm
90

30°

M8x1.25"/
31.8 mm
1.61”/ 0.51”/ 0.37”/
41.0 mm 13.0 mm 9.5 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1093


© September 2010
FE Series Nonmetallic Fluorescent Luminaire Photometric Data
Standard and Emergency Battery Back-Up. Increased Safety

Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal


Transverse
Luminaire symbol according to NF C 71-121
1 x 18 Watt 1 x 36 W 1 x 58 W
TOTAL LUMINAIRE EFFICIENCY = 94.8% Efficiency 89.3% Efficiency 87.5%
NF C 71-121: 0.86 H + 0.09 T NF C 71-121: 0.81 H + 0.08 T NF C 71-121: 0.80 H + 0.07 T
Candela Distribution Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270 0-180 90-270
0 215 215 0 205 205 0 198 198
5 214 Degrees214 5 204 Degrees203 5 197Degrees 197
10 211 215 90° 10 202 203 90° 10 194 198 90°
15 207 213 75° 15 197 202 75° 15 190 197 75°
20 200 211 20 191 201 20 184 195
60° 60° 60°
25 191 209 25 182 201 25 176 194
30 181 208 45° 30 173 200 45° 30 166 193 45°
35 169 202 35 161 192 35 155 187
40 155 196 40 148 183 40 142 180
45 139 187 45 133 177 45 128 174
30° 30° 30°
50 122 181 50 117 173 50 113 170
55 103 175 55 99 168 55 96 167
0° 15° 0° 15° 0° 15°
60 83 174 60 80 168 60 78 163
65 62 173 65 61 163 65 59 157
70 42 165 70 41 154 70 41 151

2 x 18 W 2 x 36 W 2 x 58 W
Efficiency 85.1% Efficiency 80.5% Efficiency 76.9%
NF C 71-121: 0.78 H + 0.08 T NF C 71-121: 0.73 H + 0.07 T NF C 71-121: 0.70 H + 0.07 T
Lighting

Candela Distribution Candela Distribution Candela Distribution


0-180 90-270 0-180 90-270 0-180 90-270
0 195 Degrees195 0 185 Degrees185 0 173Degrees 173
5 195 194 90° 5 185 184 90° 5 172 173 90°
10 192 192 10 182 182 10 170 171
75° 75° 75°
15 187 192 15 178 181 15 166 169
20 181 193 60° 20 172 183 60° 20 161 172 60°
25 173 194 25 164 183 25 154 172
30 163 194 30 154 183 30 145 172
Lighting: Enclosed and Gasketed — Area — Fluorescent

45° 45° 45°


35 152 193 35 143 183 35 135 171
40 138 192 40 131 183 40 123 172
45 124 191 45 117 179 45 111 170
50 108 183 30° 50 102 173 30° 50 97 165 30°
55 91 176 55 85 166 55 82 157
60 73 163 60 68 155 60 66 148
65 55 150 0° 15° 65 51 145 0° 15° 65 50 139 0° 15°
70 37 145 70 35 141 70 34 133

3 x 18 W 3 x 36 W 3 x 58 W
Efficiency 68.1% Efficiency 68.1% Efficiency 65.6%
NF C 71-121: 0.63 G + 0.05 T NF C 71-121: 0.63 G + 0.07 T NF C 71-121: 0.61 H + 0.04 T
Candela Distribution Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270 0-180 90-270
0 173 Degrees173 0 174 Degrees174 0 170Degrees 170
5 172 172 90° 5 174 174 90° 5 170 170 90°
10 169 170 75°
10 171 173 10 167 168
75° 75°
15 135 169 15 167 171 15 163 169
20 160 169 60° 20 162 171 60° 20 158 167 60°
25 153 168 25 155 170 25 151 167
30 144 167 45° 30 146 168 45° 30 143 163 45°
35 135 162 35 136 163 35 133 159
40 123 158 40 125 159 40 122 155
45 110 153 45 112 153 45 109 149
50 96 146 30° 50 98 145 30° 50 95 140 30°
55 82 136 55 83 135 55 81 129
60 66 123 60 67 123 60 65 116
0° 15° 0° 15° 0° 15°
65 50 111 65 51 110 65 49 105
70 34 100 70 35 100 70 33 96

1094 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 & 22

Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Applications
• Light duty luminaire ideal for commercial and light industrial
locations including hazardous areas designated as Zone 2 or
22 environments.
• Typical applications include oil refineries petrochemical
plants, pulp and paper mills, tunnels and other light duty
manufacturing locations. 2 x 58 W
Features
• Utilizes two 26 mm (T8) bi-pin fluorescent lamps.
• Fiberglass reinforced polyester housing.
• Instant start 95% power factor ballast.
• Available in various lengths and wattages ranging from 18 to 58.
Pre-impregnated fiberglass reinforced white polyester housing. 2 x18 W
• Closing system using stainless steel clips.
• Electrostatically applied white powder painted steel reflector
provides optimal lighting distribution.
• Poured-in-place elastomer gasket secures IP65 / 67 ingress
protection.
Standard Material Certifications and Compliances
• Fiberglass reinforced polyester (FRP) housing • Certification Type: EFn (Standard Version) / EFn-EM
• Polycarbonate lens (Emergency Version
• White powder painted sheet steel reflector • Zone 2
• Elastomer gasket — Conforming to ATEX 94/9/CE: CE II 3 G
• Polycarbonate lampholders — ATEX/IEC Protection: Ex nR II or Ex nA II
• Mounting accessories available in different materials such — T Rating: T4 for nA protection mode.
as gray painted aluminum, zinc plated steel, galvanized steel See temperature chart for nR protection mode

Lighting
or 316 stainless steel • Zone 22
Options — Conforming to ATEX 94/9/CE: CE II 3 D
— ATEX/IEC Protection: Ex tD A22
• Available in 3 hours emergency version, including multi-tap — Surface Temperature: (See table)
ballast with built-in monthly self test. Test results through multi- • Ambient Temperature: -4 °F to 131 °F / -20 °C to +55 °C
colored LED. • CE Declaration of Conformity: 50213/50219
• Plug-in battery pack is easy to remove for maintenance. • ATEX Certificate: LCIE 08.6005X / LCIE 08.6063X
• Battery voltage is 6 volts and 4 Ah capacity. • IECEx Certificate: LCIE Ex 08.007X / LCIE Ex 08.008X

Lighting: Enclosed and Gasketed — Area — Fluorescent


• One fluorescent tube remains lit for up to 3 hours and up to 29% • Index of Protection (solid & liquid): IP65 / 67
light intensity for 18 Watt, 15% for 36 Watt and 9% for 58 Watt. • Time Before Opening: 10mn
• All emergency units supplied with cut off switch to battery when • Ex Standards: EN / IEC 60079-15; 61241-0; 61241-1
fixture is opened. • Product Standards: EN / IEC 60598-1; 60598-2-22
• EMC Standards: EN / IEC 55015; 61547
• Other Standards: EN / IEC 60529 (IP)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1095


© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 & 22

Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FN Non-Metallic Fluorescent Lighting Fixtures
FN B 1 18 BU P A C

Series: Wattage: Cable Type:


FN - FN Series 18 - 18 Watt A - Armored M20
Zone 2, 21 & 22 36 - 36 Watt N - Unarmored M25
ATEX/IEC Certified 58 - 58 Watt U - Unarmored M20
55 - 55 Watt
80 - 80 Watt

Lamp Type: Voltage: Options:


B - Bi-pin (G13) BU - 110 to 254 Vac/Vdc (Options must be listed
C - PL Compact Lamps 50/60 Hz alphabetically)
(2G11) ② BK - 220 to 240 Vac/Vdc C - Silicon Coating for
50/60 Hz Diffuser
E - 3H Emergency
(combined) - Battery
6 V - 4 Ah
N - No Switch ③
X - 4 Entries ④

Number of Lamps: Mounting Version:


1 - Single P - Pole Mount ①
2 - Double S - Surface/Suspension Mount
3 - Three Lamps Standard Wiring
T - Surface/Suspension Mount
Lighting

Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)
Lighting: Enclosed and Gasketed — Area — Fluorescent

Temperature Chart
Dust Gas
Surface T Rating for Ta = T Rating for Ta = T Rating for Ta =
Version Temp. 104° F/40° C 122°F/50°C 131°F/55°C
1 x 18 W T6 T6 T6
167°F/75°C
2 x 18 W T6 T5 T5

1 x 36 W T6 T6 T5
181°F/83°C
2 x 36 W T6 T6 T5

1 x 58 W T5 T5 T5
196°F/91°C
2 x 58 W T5 T5 T5

① Only 2 x 18 W and 2 x 36 W with M25 entry versions.


② Only 55 W and 80 W standard versions.
③ Only for standard versions.
④ Only for S, T and L mounting versions.

1096 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 & 22

Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Standard Version for Armored and Unarmored Cable


Supplied with one M20 cable entry at each end plus two locknuts, two earth continuity and one blanking plug.
Also supplied with one 2 x (0.004 x 0.003 in2 / 3 x 2.5 mm2) max. flexible or rigid connection terminal block.

Number Watts Voltage Weight Volume Pack. Catalog


of Lamps (V) (lbs/kg) (in3/dm3) Number
1 18 220/240 5.07/2.3 1360.83/22.3 1 FLB118BKSA
2 18 220/240 5.07/2.3 1360.83/22.3 1 FLB218BKSA
2 18 110/254 5.07/2.3 1360.83/22.3 1 FLB218BUSA
1 36 220/240 6.17/2.8 2318.90/38 1 FLB136BKSA
1 36 110/254 6.17/2.8 2318.90/38 1 FLB136BUSA
2 36 220/240 7.94/3.6 2318.90/38 1 FLB236BKSA
2 36 110/254 7.94/3.6 2318.90/38 1 FLB236BUSA
1 58 220/240 7.50/3.4 2746.07/45 1 FLB158BKSA
1 58 110/254 7.50/3.4 2746.07/45 1 FLB158BUSA
2 58 220/240 9.70/4.4 2746.07/45 1 FLB258BKSA
2 58 110/254 9.70/4.4 2746.07/45 1 FLB258BUSA

Lighting
Emergency Version for Armored and Unarmored Cable
Supplied with one M20 entries with earth continuity at each end. Also supplied with two M20 locknuts and one blanking plug.
Equipped with one 2 x (0.008 x 0.003 in2 / 5 x 2.5 mm2) max. flexible or rigid connection terminal block
Number Watts Voltage Weight Volume Pack. Catalog
of Lamps (V) (lbs/kg) (in3/dm3) Number
2 18 110/254 9.92/4.5 1360.83/22.3 1 FLB218BUSAE

Lighting: Enclosed and Gasketed — Area — Fluorescent


2 36 110/254 15.43/7.0 2318.90/38 1 FLB236BUSAE
2 58 110/254 16.53/7.5 2746.07/45 1 FLB258BUSAE

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1097


© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaire Accessories
Standard and Emergency Back-Up. Zone 2 & 22

Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Description Pack Catalog Number


Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel 1 FEFBZ
316 stainless steel 1 FEFBS

Brackets for Surface Mounting


Set of two
Aluminum (gray painted) 1 FESBA
316 stainless steel 1 FESBS
M8 Ring Bolts
Set of two
Zinc plated steel 1 FERBM8Z

Half Clamps Brackets for Pole Mounting


Set of two
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
Zinc plated steel 1 FEHC49Z
316 stainless steel 1 FEHC49S
Lighting

Dia. 2.36"/60 mm pole (2"/50.8mm tube)


Zinc plated steel 1 FEHC60Z
316 stainless steel 1 FEHC60S
Hinged Brackets
Lighting: Enclosed and Gasketed — Area — Fluorescent

Set of two brackets for adjusting luminaire


Aluminum 1 FEHBA
316 stainless steel 1 FEHBS
Fall Prevention Kit
1.20 M stainless steel chain 1 FDSCS

1098 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaire Technical Data
Standard and Emergency Back-Up. Zone 2 & 22

Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Emergency Function Diagram — Emergency Function 2 Tubes


Mains Lighting Switch ON Lighting Switch OFF

Fluorescent Luminaire ON

Fluorescent Luminaire OFF

Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal
Transverse
Luminaire symbol according to NF C 71-121
1 x 18 W 2 x 18 W
Efficiency 67.8% Efficiency 68.9%
NF C 71-121: 0.58 H + 0.09 T NF C 71-121: 0.60 H + 0.09 T

Candela Distribution Candela Distribution


0-180 90-270 0-180 90-270
0 142 142 0 116 116
5 142 142 Degrees 5 115 119 Degrees
90° 90°

Lighting
10 139 140 10 113 133
15 135 135 75° 15 110 150 75°
20 130 132 20 105 156
60° 60°
25 123 128 25 100 157
30 113 126 45° 30 94 158
45°
35 102 128 35 88 159
40 90 132 40 81 158
45 78 136 45 74 157 30°

Lighting: Enclosed and Gasketed — Area — Fluorescent


30°
50 66 134 50 65 152
55 54 131 55 55 145
0° 15°
60 43 129 0° 15° 60 45 137
65 33 119 65 35 128
70 23 110 70 25 114

2 x 36 W 2 x 58 W
Efficiency 64.1% Efficiency 63.6%
NF C 71-121: 0.57 H + 0.07 T NF C 71-121: 0.56 H + 0.07 T
Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270
0 163 163 Degrees 0 160 160 Degrees
5 162 162 90° 5 159 160 90°
10 160 159 10 157 157
75° 75°
15 155 145 15 153 146
20 149 140 60° 20 148 140 60°
25 142 139 25 141 139
30 132 139 30 132 139
45° 45°
35 120 138 35 121 138
40 104 134 40 107 134
45 80 133 45 85 132
30° 30°
50 60 129 50 68 127
55 50 125 55 56 122
60 40 120 60 45 117
0° 15° 0° 15°
65 31 108 65 35 107
70 23 95 70 24 90

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1099


© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 - 21 & 22

Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Applications
• Can be installed in hazardous areas designated as Zone 2,
21 and 22.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor/outdoor use where protection against dirt, water and 2 x 58 W
moisture is necessary.
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general
manufacturing facilities.
Features 2 x 36 W
• Corrosion-resistant fiberglass reinforced polyester body and
hinged polycarbonate lens.
• High impact resistance housing (20 Joules - IK10) from
-40° F to 131 °F / -40°C to 55 °C ambient temperature
and wind profile for use in extreme offshore and onshore
2 x 18 W
environments.
• Latch assembly and elastomer gasket seals against water and
dust ingress, IP66/67.
• Easily accessed for maintenance using Allen key or straight
blade screw driver.
• Central opening with unique patented release system to
prevent damage.
• Hinged parabolic reflector for high lumen output efficiency.
• Vibration resistant spring loaded lampholders for Bi-pin (G13) or
mono-pin (Fa6) versions.
Lighting

• Electronic multi-tap ballast 110 to 254 Vac/Vdc +/- 10% 50/60


Hz, for global applications. High power factor electronic ballast
(>0.95). EOL (End Of Life) protection in accordance to the latest
EN/IEC 60079-7 standard.
• Also available with electronic ballast 220/240 Vac/Vdc +/- 10% Certifications and Compliances
50/60 Hz. High power factor electronic ballast (>0.95). EOL. • Certification Type: FLd
• Available in 3 hours emergency version, including multi-tap • Zone 2
ballast with built-in monthly self test. Test results through — Conforming to ATEX 94/9/CE: CE II 3 G
Lighting: Enclosed and Gasketed — Area — Fluorescent

multi-color LED. — ATEX/IEC Protection: Ex nR II or Ex nA II


— T Rating: T6 to T4
Standard Material • Zone 21 and 22
• Fiberglass reinforced polyester housing — Conforming to ATEX 94/9/CE: CE II 2 D, CE II 3 D
• Polycarbonate lens — ATEX/IEC Protection: Ex tD A21
• Elastomer gasket — Surface Temperature: T167 °F/75 °C
• Highly reflective white polycarbonate internal reflector • Ambient Temperature: -40 °F to 131 °F / -40 °C to 55 °C
• Mounting accessories available in different materials such as • CE Declaration of Conformity: 50212/50225
gray painted aluminum, zinc plated steel, galvanized steel or • ATEX Certificate: LCIE 03 ATEX 6072/6166
316 stainless steel • IECEx Certificate: IECEx LCI 04.0021
Options • Other Certifications: GOST, Marine Listed UL 1598A
• Index of Protection (solid & liquid): IP66/67
• Silicone coating for added protection in H2S hydrogen • Impact Resistance (shock): IK10
sulfide environments. • Ex Standards: EN / IEC 60079-15; 61241-0; 61241-1
• Without safety switch. • Product Standards: EN / IEC 60598-1; 60598-2-22
• Level gauge light fitting. • EMC Standards: EN / IEC 55015; 61547
• 316 stainless steel fixing inserts. • Other Standards: EN / IEC 60529 (IP); 62262 (IK)

1100 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 - 21 & 22

Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FN Non-Metallic Fluorescent Lighting Fixtures
FN B 1 18 BU P A C

Series: Wattage: Cable Type:


FN - FN Series 18 - 18 Watt A - Armored M20
Zone 2, 21 & 22 36 - 36 Watt N - Unarmored M25
ATEX/IEC Certified 58 - 58 Watt U - Unarmored M20
55 - 55 Watt
80 - 80 Watt

Lamp Type: Voltage: Options:


B - Bi-pin (G13) BU - 110 to 254 Vac/Vdc (Options must be listed
C - PL Compact Lamps 50/60 Hz alphabetically)
(2G11) ② BK - 220 to 240 Vac/Vdc C - Silicon Coating for
50/60 Hz Diffuser
E - 3H Emergency
(combined) - Battery
6 V - 4 Ah
N - No Switch ③
X - 4 Entries ④

Number of Lamps: Mounting Version:


1 - Single P - Pole Mount ①
2 - Double S - Surface/Suspension Mount
3 - Three Lamps Standard Wiring
T - Surface/Suspension Mount

Lighting
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)

Lighting: Enclosed and Gasketed — Area — Fluorescent

① Only 2 x 18 W and 2 x 36 W with M25 entry versions.


② Only 55 W and 80 W standard versions.
③ Only for standard versions.
④ Only for S, T and L mounting versions.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1101


© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 - 21 & 22

Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Standard Version
Surface/Suspension Mounting and Standard Wiring
Version
Connection via 1 x 6 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13)


Three M25 threaded entries, two at one end and one at opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide blanking plugs.
Number Power Lamp Voltage Weight Volume Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 G13 220/240 12.13/5.5 1971.07/32.3 FNB218BKSNN
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FNB218BUSNN
2 36 G13 220/240 17.42/7.9 3307.49/54.2 FNB236BKSNN
2 36 G13 110/254 17.42/7.9 3307.49/54.2 FNB236BUSNN
2 58 G13 220/240 19.84/9 3966.54/65 FNB258BKSNN
2 58 G13 110/254 11 3966.54/65 FNB258BUSNN
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.

Number Power Lamp Voltage Weight Volume Catalog


of Lamps (W) Type (V) (lbs/kg) (in3/dm3) Number
2 18 G13 220/240 12.13/5.5 1971.07/32.3 FNB218BKSAN
2 18 G13 110/254 12.13/5.5 1971.07/32.3 FNB218BUSAN
Lighting

2 36 G13 220/240 17.42/7.9 3307.49/54.2 FNB236BKSAN


2 36 G13 110/254 17.42/7.9 3307.49/54.2 FNB236BUSAN
2 58 G13 220/240 19.84/9 3966.54/65 FNB258BKSAN
2 58 G13 110/254 24.25/11 3966.54/65 FNB258BUSAN
Emergency Version
Surface/Suspension Mounting and Standard Wiring
Connection via 1 x 4 terminals for 18 W version.
Lighting: Enclosed and Gasketed — Area — Fluorescent

Connection via 1 x 8 terminals for 36 W & 58 W


versions.
Capacity (flexible/solid): 4 mm2/6 mm2. 18 W 36/58 W
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at opposite end, supplied with
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two
M25 polyamide blanking plugs.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 G13 110/254 16.09/7.3 1971.07/32.3 3H 4 Ah FNB218BUSNEN
2 36 G13 110/254 21.16/9.6 3307.49/54.2 3H 4 Ah FNB236BUSNEN
2 58 G13 110/254 23.59/10.7 3966.54/65 3H 4 Ah FNB258BUSNEN
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number Power Lamp Voltage Weight Volume Duration Battery Catalog
of Lamps (W) Type (V) (lbs/kg) (in3/dm3) (Hours) Capacity Number
2 18 G13 110/254 16.09/7.3 1971.07/32.3 3H 4 Ah FNB218BUSAEN
2 36 G13 110/254 21.16/9.6 3307.49/54.2 3H 4 Ah FNB236BUSAEN
2 58 G13 110/254 23.59/10.7 3966.54/65 3H 4 Ah FNB258BUSAEN

1102 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Accessories
Standard and Emergency Back-Up. Zone 2 - 21 & 22

Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Description Pack Catalog Number


Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel 1 FEFBZ
316 stainless steel 1 FEFBS

Brackets for Surface Mounting


Set of two
Aluminum (gray painted) 1 FESBA
316 stainless steel 1 FESBS
M8 Ring Bolts
Set of two
Zinc plated steel 1 FERBM8Z

Half Clamps Brackets for Pole Mounting


Set of two
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
Zinc plated steel 1 FEHC49Z
316 stainless steel 1 FEHC49S

Lighting
Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Zinc plated steel 1 FEHC60Z
316 stainless steel 1 FEHC60S
Wall Mounting Adaptor

Lighting: Enclosed and Gasketed — Area — Fluorescent


For pole mounting version (dia. 1.65"/42 mm)
Galvanized steel 1 FEWMG

Hinged Brackets
Set of two brackets for adjusting luminaire
Aluminum 1 FEHBA
316 stainless steel 1 FEHBS

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1103


© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Technical Data
Standard and Emergency Back-Up. Zone 2 - 21 & 22

Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Wiring Diagram Emergency Function Diagram


Two Lamp Version
Mains
Mains Lighting Switch ON Lighting Switch OFF
PE N L

Lighting
Switch ON

L’

U
OFF
Standard Fluorescent
N Lighting Fixture
PE
Three Lamp Version

Mains Lighting Switch ON Lighting Switch OFF

U’ ON
U Emergency Fluorescent
N Lighting Fixture
PE

OFF
Lighting

LED Status
Color Indication Function
LED glows Batteries are connected
Green
LED blinks Batteries are charged
Red LED blinks Batteries are not connected or defect
Lighting: Enclosed and Gasketed — Area — Fluorescent

Yellow LED blinks Batteries are charging and discharging during automatic cycle

Dimensions

Surface/Suspension Mounting

18 W 36 W
2 X MB 2 X MB
27.56"/ 700.0 mm
15.75"/
400 mm

30.91"/785.0mm 54.72"/ 1390.0 mm

2 X MB
5.71"/ 58 W 27.56"/ 700.0 mm
145.0 mm

66.54"/ 1690.0 mm
8.54"/
217.0 mm

1104 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Photometric Data
Standard and Emergency Back-Up. Zone 2 - 21 & 22

Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal


Transverse
Luminaire symbol according to NF C 71-121
2 x 18 W 2 x 36 W 2 x 58 W
Efficiency 85.1% Efficiency 80.5% Efficiency 76.9%
NF C 71-121: 0.78 H + 0.08 T NF C 71-121: 0.73 H + 0.07 T NF C 71-121: 0.70 H + 0.07 T
Candela Distribution Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270 0-180 90-270
0 195 195 0 185 185 0 173 173
5 195 194
Degrees
5 185 184
Degrees
5 172 173
Degrees

10 192 192 90° 10 182 182 90° 10 170 171 90°


15 187 192 75° 15 178 181 75° 15 166 169 75°
20 181 193 60°
20 172 183 20 161 172
60° 60°
25 173 194 25 164 183 25 154 172
30 163 194 45° 30 154 183 45° 30 145 172 45°
35 152 193 35 143 183 35 135 171
40 138 192 40 131 183 40 123 172
45 124 191 30°
45 117 179 45 111 170
30° 30°
50 108 182 50 102 173 50 97 165
55 91 176 55 85 166 55 82 157
0° 15° 0° 15° 0° 15°
60 73 163 60 68 155 60 66 148
65 55 150 65 51 145 65 50 139
70 37 145 70 35 141 70 34 133

Lighting
Lighting: Enclosed and Gasketed — Area — Fluorescent

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1105


© September 2010
RigMaster™ Metallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

Class I, Division 2, Groups A, B, C, D


NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②

Applications
• Enclosed and gasketed fixtures for use where vapors, moisture,
dirt or corrosive atmospheres are encountered.
• For use in hazardous locations defined by the NEC as Class
I, Division 2. Groups A, B, C & D; Marine Type Electric Fixture
Non-Recessed Outside Type (Salt Water); UL1598A; and
Type 4X.
• For use in locations where a high degree of corrosion resistance
RM2232BUSW
is required.
• For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
• Typical applications include:
— Oil drilling rigs
— Marine loading terminals
— Processing plants
— Pipeline pumping stations Illustrated Feature
— Water treatment plants
— Lubrication pits
Features
• Choice of mountings: end brackets, swivel brackets and straight
brackets.
• Thick 1/8” clear acrylic lens protects against possible broken
glass from lamps.
• RigMaster fixtures are supplied with the following ballast Four plated steel latches on each side of door assure
options: integrity of fixture for areas as classified.
— Class P low energy (E) ballasts, equipped with an automatic
thermally-activated protective device. They offer protection
Lighting

against excessive voltage, internal ballast short circuiting,


inadequate lamp maintenance and improper fixture
application.
— 220- and 240-volt options in both 50 and 60 Hz.
• High-temperature nickel-cadmium battery has a life expectancy
of 7 to 10 years. Certifications and Compliances
• Battery charger indicator light and test switch are mounted • UL Standard: UL 1598, UL 844, UL 924
inside the enclosure and visible through the clear lens. • UL Listed: E10794
Lighting: Enclosed and Gasketed — Area — Fluorescent

• Heavy-duty telescoping lampholders.


• Fixtures are shipped complete with lamps.
• Swivel End Mount fixture comes standard with eyebolt on fixture
end for connecting safety cable.
• Swivel Center Mount and Straight Center Mount fixtures come
standard with cast mounts on fixture end for connecting safety
cable.
Standard Materials
• Reflector housings: extruded aluminum
• Door frame: 1/8” extruded aluminum
• Door clamps: heavy-duty plated spring steel
• Lampholders: white urea plastic
• Gasket: neoprene
Options
• Individually fused ballast: suffix –F.
• Emergency battery pack: suffix –EL ①.
• Emergency Battery Pack capability in moments of power
interruption. Luminaire automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.

① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.

1106 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
RigMaster™ Metallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

Class I, Division 2, Groups A, B, C, D


NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For RigMaster Metallic Fluorescent Lighting Fixtures
RM 2 2 40 12 SS CB EL

Series: Lamp Type: Mounting:


RM - RigMaster 32 - 32 W, T8 CB- End
Metallic (Electronic) SW- Swivel
40 - 40 W, (Electronic) ST- Fixed
60 - 60 W, T12, HO
800 MA (48) ⑤

Hazardous Rating: Voltage ④: Options:


Class I, Division 2 12 - 120 V (40 W, T12) EL- Emergency
27 - 277 V (40 W, T12) Battery Pack ③
BU - 120-277 V, 50/60 Hz F- Fuse
(32 W, T8; 60 W, T12)

Number of Lamps: Ballast Type:


2 - Two Lamps SS- Solid State (40W, T12,
Electronic) Only

Thermal Performance RigMaster Fixtures

Lighting
Lamp
Ambient Temp “T” Hazardous
Fixture Quantity Watt Type (°F/°C) Numbers Classification
RM2232 2 32 265MA-RS 104/40 T-4 Class I, Division 2, Groups A, B, C, D
RM2240 2 40 430MA-RS 104/40 T-4 Class I, Division 2, Groups A, B, C, D
RM2260 2 60 800MA-HO 104/40 T-4 Class I, Division 2, Groups A, B, C, D

Lighting: Enclosed and Gasketed — Area — Fluorescent

① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.
③ For 50 Hz with Emergency Battery Pack, consult factory for certification.
④ BU for 32 W, T8 and 60 W, T12 only. Voltage must be specified for 40 W, T12.
⑤ CW suffix not needed for 60 W since -20 °F/-28 °C starting provided as a standard.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1107


© September 2010
RigMaster™ Metallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

Class I, Division 2, Groups A, B, C, D


NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②

No. of Lamp Lamp Bracket Catalog


Lamps ③ Wattage Type Volts Type Number
2 32 T8 120-277 V, 50/60 Hz end RM2232BUCB
2 40 T12 120 V, 60 Hz end RM224012SSCB
2 40 T12 277 V, 60 Hz end RM224027SSCB
Swivel End Bracket 2 60 T12 120-277 V, 50/60 Hz end RM2260BUCB
2 32 T8 120-277 V, 50/60 Hz swivel RM2232BUSW
2 40 T12 120 V, 60 Hz swivel RM224012SSSW
2 40 T12 277 V, 60 Hz swivel RM224027SSSW
Swivel Center Bracket 2 60 T12 120-277 V, 50/60 Hz swivel RM2260BUSW
2 32 T8 120-277 V, 50/60 Hz straight RM2232BUST
2 40 T12 120 V, 60 Hz straight RM224012SSST
2 40 T12 277 V, 60 Hz straight RM224027SSST
Straight Center Bracket 2 60 T12 120-277 V, 50/60 Hz straight RM2260BUST

Replacement Parts
Description Catalog Number
Lens
Lighting

Lens and Frame Assembly RIGLENS


Mounting Brackets
Straight Bracket RM3002SEM
Angle Bracket RM3002AEM
Swivel Bracket RMBMSW
Lighting: Enclosed and Gasketed — Area — Fluorescent

Back-Straight Bracket RMBMST


Sockets
60 W Spring Loaded RM60SRS
60 W Fixed Replacement RM60FRS
32 W Replacement RM32RS

Mounting Accessories — Safety Cable


Galvanized Steel Cable Catalog Number Stainless Steel Cable Catalog Number
3 ft/0.9 m RMSC3GASL 3 ft/0.9 m RMSC3STSL
4 ft/1.2 m RMSC4GASL 4 ft/1.2 m RMSC4STSL

Connecting Safety Cable

Swivel Center Mount and Straight Center


Swivel End Mount fixture comes standard with
Mount fixture comes standard with cast
eyebolt on fixture end for connecting safety
mounts on fixture end for connecting
cable.
safety cable.

① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.
③ Fixtures shipped complete with lamps.

1108 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
RigMaster™ Metallic Fluorescent Luminaire Dimensions
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

End Bracket Mounting

mm
.8
3 01
"/1
.25 m
51 .8
m
93
" / 11 o C
.0 C t
47

8.10"/
205.7 mm
8.10"/205.7 mm

5.42"/137.7 mm

Swivel Bracket Mounting

2.00"/50.8 mm
"/
.50 m
12 m
7 .5
31

Ø 0.28"/
7.0 mm

Lighting
9.75"/ 10.35"/
247.7 mm 262.9 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent


17.6"/447.0 mm

Straight Bracket Mounting

/
.0"
11 .4 mm
9
27

6.75"/
171.5 mm

Fixture Bracket Type Weight in Lbs/Kgs


End 35/15.9
Swivel 35/15.9
Straight 35/15.9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1109


© September 2010
RigMaster™ Metallic Fluorescent Luminaire Photometrics
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

Candela Distribution CATALOG NUMBER: RM2232BU


Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-8. 32 Watt) tested at
0.0 22.5 45.0 67.5 90.0 Flux
120 V
0 1234 1234 1234 1234 1234 Lamps: Two Phillips 32 W, 4-foot F32T8/TL741fluorescents
5 1234 1228 1227 1228 1224 117 Ballast: Advance T-8, 32 Watt, catalog number ICN-2P32-SC 50/60 Hz, Instant Start, 120-277 V
Ambient Temperature: 24 °C/75 °F
15 1183 1187 1185 1187 1183 335
Mounting: With Bracket
25 1106 1110 1109 1110 1106 512 Based on: 2,850 Lumens per Lamp
35 984 990 996 990 984 620 TOTAL LUMINAIRE EFFICIENCY = 57.6% ZONAL LUMEN SUMMARY
45 813 823 830 823 813 634 CIE Type – Direct ZONE LUMENS % LAMP % FIXT.

55 612 619 614 619 612 550 Plane: 0˚ 90˚ 0- 30 964 16.9 29.4

65 364 375 381 375 364 368 Spacing Criteria: 1.3 1.3 0- 40 1584 27.8 48.3

75 124 126 112 126 124 133 Shielding Angles: 1.0 0.0 0- 60 2767 48.6 84.3

85 9 7 7 7 9 12 0- 90 3281 57.6 100.0

90 1 1 1 1 90-180 0 0.0 0.0


0-180 3281 57.6 100.0

Candela Distribution CATALOG NUMBER: RM2232BU


Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 34 Watt) tested at
0.0 22.5 45.0 67.5 90.0 Flux
120 V
0 1132 1132 1132 1132 1132 Lamps: 2 Philips 34 Watt (4 foot, T-12) F4OCW/RS/EW
5 1124 1128 1126 1128 1124 107 Ballast: Advance T-12, 34 Watt, catalog number REL-2S40-SC 50/60 Hz, Instant Start, 120 V
Ambient Temperature: 24 °C/75 °F
15 1085 1089 1090 1089 1085 308
Lighting

Mounting: With Bracket


25 1003 1010 1011 1010 1003 465 Based on: 2,650 Lumens per Lamp
35 882 889 888 889 882 555 TOTAL LUMINAIRE EFFICIENCY = 55.1% ZONAL LUMEN SUMMARY
45 726 730 726 730 726 561 CIE Type – Direct ZONE LUMENS % LAMP % FIXT.

55 535 535 533 535 535 477 Plane: 0˚ 90˚ 0- 30 880 16.6 30.1

65 322 316 311 316 322 314 Spacing Criteria: 1.2 1.2 0- 40 1435 27.1 49.2
Lighting: Enclosed and Gasketed — Area — Fluorescent

75 121 112 104 112 121 121 0- 60 2473 46.7 84.7

85 9 7 6 7 9 11 0- 90 2919 55.1 100.0


90 0 0 0 0 0 90-180 0 0.0 0.0
0-180 2919 55.1 100.0

Candela Distribution
CATALOG NUMBER: RM2260BU
0.0 22.5 45.0 67.5 90.0 Flux Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 60 Watt) tested
0 1237 1237 1237 1237 1237 Lamps: 2 Philips 60 Watt (4 foot, T-12) F48T12CWHO ALTO
Ballast: Advance T-12, 60 Watt, catalog number VEL-2S110
5 1227 1231 1229 1231 1227 117
Ambient Temperature: 24 °C/75 °F
15 1188 1194 1193 1194 1188 337 Mounting: With Bracket
25 1100 1108 1111 1108 1100 511
Based on: 4,050 Lumens per Lamp

35 968 977 976 977 968 610 TOTAL LUMINAIRE EFFICIENCY = 39.6% ZONAL LUMEN SUMMARY
45 800 806 805 806 800 619 CIE Type – Direct ZONE LUMENS % LAMP % FIXT.

55 591 593 594 593 591 529 Plane: 0˚ 90˚ 0- 30 965 11.9 30.1

65 351 352 351 352 351 347 Spacing Criteria: 1.2 1.2 0- 40 1574 19.4 49.1

75 122 116 106 116 122 127 0- 60 2722 33.6 84.8

85 10 8 6 8 10 12 0- 90 3208 39.6 100.0


90 0 0 0 0 0 90-180 0 0.0 0.0
0-180 3208 39.6 100.0

1110 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
RigMaster™ 304 Stainless Steel Fluorescent Luminaires V
CSA Certification Only. Enclosed and Gasketed. For Hazardous and Adverse Locations
Suitable for use in Wet or Marine (Salt Water) Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

Class I, Division 2, Groups A, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3

Applications
• Appleton Rigmaster is designed for the requirements of the oil
drilling industry.
• For use on seashore, offshore or land based drilling rigs.
• Suitable for industrial applications requiring a highly corrosion-
resistant fluorescent fixture.
• Approved for outdoor use.
• Ideal for shipboard use. (Salt water environment).
• For use in high vibration installations.
• Can be installed to illuminate work areas, stairways and ladders,
pumps and instrument panels, chemical plants and refineries or
for shipboard deck lighting.
Features
• Corrosion-resistant durable seam welded 304 stainless steel
construction. Standard Materials
• Vibration resistant – spring loaded sockets hold lamps securely • Fixture body, snap clips, hardware, lens frame: 304 stainless
with maximum shock and vibration protection. steel
• Positive seal lens assembly provides a secure gasketed seal • Mounting brackets, CG connectors, reflector: copperfree (4/10
around the lens. Lexan, impact resistant lens is standard. of 1% max.) aluminum
• CG series watertight cord connectors grip the cable securely at Standard Finishes
the point of entrance to prevent insulation wear and strain on
connections made within the enclosure. CG connectors seal out • All components have a natural finish
oil, water and other harmful atmospheres containing moisture to Options
keep the enclosure clean and dry.
• Emergency battery, operates lamps at 60% for 90 minutes
• Stainless steel snap action clips permit relamping without tools.
during power outages, suffix -E.
Three clips serve as hinges allowing unobstructed access to the
• Fabricated from 316 stainless steel, suffix -316.
fixture interior.
• 60 Watt high output ballast available (-20 °F/-29 °C starting

Lighting
• The highly polished finished reflector has excellent light
temperature).
distribution and high efficiency.
• Lens: tempered glass, suffix -GN.
• Access to the ballast and wiring chamber is quick and easy,
requiring the removal of two screws. Compliances
• Rigmasters are provided with feed-thru wiring, eliminating the • CSA Standard: C22.2 No. 250, C22.2 No. 137
need for a junction box. • CSA Certified: 025428

Lighting: Enclosed and Gasketed — Area — Fluorescent


Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For RigMaster Stainless Steel Fluorescent Lighting Fixtures — Bracket Mounted
ARM 2 4 A BU GN

Series: Cable Entry


ARM - RigMaster Jacket Range:
Stainless Steel A - .312”to .437”
B - .375” to .500”
C - .500" to .625"

Number of Lamps: Voltage:


2 - Two Lamps BU - 120-277 V 50/60 Hz
A5 - 347 V 60 Hz

Lamp Type: ① Factory Installed Options:


32 - 32 W, T8 (Electronic) EL- Emergency Back-up Battery
40 - 40 W, T12 (Rapid Start) 316 - 316 Stainless Steel
60 - 60 W, T12 (High Output) GN - Tempered Glass Lens

① Lamps not furnished with fixture.


V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1111


© September 2010
RigMaster™ 304 Stainless Steel Fluorescent Luminaires V
CSA Certification Only. Enclosed and Gasketed. For Hazardous and Adverse Locations
Suitable for use in Wet or Marine (Salt Water) Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

Class I, Division 2, Groups A, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3

No. of Lamp Lamp Operating Input Cable Catalog


Lamps ① Wattage Type Volts Amps Watts Range Number
Rapid Start — 48” — T8 — Minimum Starting Temperature 0 °F/-18 °C
2 32 T8 120-277 V 0.49 - 0.19 59 - 55 .312-.437 ARM232ABU
2 32 T8 347 V 0.21 62 .312-.437 ARM232AA5
2 32 T8 120-277 V 0.49 - 0.19 59 - 55 .375-.500 ARM232BBU
2 32 T8 347 V 0.21 62 .375-.500 ARM232BA5
2 32 T8 120-277 V 0.49 - 0.19 59 - 55 .500-.625 ARM232CBU
2 32 T8 347 V 0.21 62 .500-.625 ARM232CA5
Rapid Start — 48” — F48T12/CW — Minimum Starting Temperature -22 °F/-30 °C
2 40 T12 120-277 V 0.7 - 0.26 84 - 70 .312-.437 ARM240ABU
2 40 T12 347 V 0.28 96 .312-.437 ARM240AA5
2 40 T12 120-277 V 0.7 - 0.26 84 - 70 .375-.500 ARM240BBU
2 40 T12 347 V 0.28 96 .375-.500 ARM240BA5
2 40 T12 120-277 V 0.7 - 0.26 84 - 70 .500-.625 ARM240CBU
2 40 T12 347 V 0.28 96 .500-.625 ARM240CA5
Rapid Start — 48” — 800 mA — F48T12/CW/HO — Minimum Starting Temperature -22 °F/-30 °C
2 60 T12 120-277 V 1.05 - 0.40 122 - 108 .312-.437 ARM260ABU
Lighting

2 60 T12 347 V 0.45 144 .312-.437 ARM260AA5


2 60 T12 120-277 V 1.05 - 0.40 122 - 108 .375-.500 ARM260BBU
2 60 T12 347 V 0.45 144 .375-.500 ARM260BA5
2 60 T12 120-277 V 1.05 - 0.40 122 - 108 .500-.625 ARM260CBU
2 60 T12 347 V 0.45 144 .500-.625 ARM260CA5
Lighting: Enclosed and Gasketed — Area — Fluorescent

Dimensions in Inches/Millimeters

① Lamps not furnished with fixture.


V CSA Certification Only.

1112 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

VRS: DRS:
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups F, G
Class III

Applications
• VRS
— Enclosed and gasketed fixtures for use where vapors,
moisture, dirt or corrosive atmospheres are encountered.
— Corrosion-resistant polyester powder coating protects
against corrosive atmospheres.
• DRS
— Dust-ignitionproof fixtures for use where ignitable amounts
of dust are present from handling such products as grain,
flour, sugar, starch and textiles.
— Suitable for use in Class II and III, Division 1, classified areas.
— Corrosion-resistant finish prolongs fixture life and retains
fixtures reflectivity longer.
Features
• Choice of mountings: pendant and feed thru are standard,
angle bars for chain suspension, or angle brackets (up to 45°) VRS Enclosed and Gasketed DRS Dust-Ignition Proof
for wall or ceiling mounting.
• Thick 1/4” clear tempered glass lens protects against possible
broken glass from lamps.
• VRS and DRS fixtures are supplied with the following
ballast options: Illustrated Features
— Class P low energy (E) ballasts, equipped with an automatic
thermally activated protective device. They offer protection
against excessive voltage, internal ballast short circuiting,
inadequate lamp maintenance and improper fixture
application
• High-temperature nickel cadmium battery has a life expectancy

Lighting
of 7 to 10 years.
• Battery charger indicator light and test switch are mounted
inside the enclosure and visible through the clear lens.
• Heavy duty telescoping lampholders.
• Low operating cost provides more lumens per Watt than Three plated steel latches on each side of door
incandescent. assure integrity of fixture for areas as classified.
• Easy cleaning one-piece, seamless welded construction virtually
eliminates dust and moisture accumulation.

Lighting: Enclosed and Gasketed — Area — Fluorescent


Standard Materials
• Reflector housings: 20-gauge steel
• Door frame: 16 gauge steel with clear glass
• Door clamps: heavy-duty plated spring steel
• Suspension hubs: 1/2” die-cast aluminum
• Lampholders: white urea plastic
• Gaskets: VRS – neoprene; DRS – fiberglass
Pan mounted ballast and sockets with safety
Standard Finishes chain provide quick, safe maintenance.
• Reflector housings: VRS – white polyester powder coating; DRS
– white polyester powder coating
• Door frame: zinc electroplate
• Door clamps, suspension hubs and lampholders: natural finish
Options Certifications and Compliances
• Individually fused ballast. Suffix -F. • UL Standard: UL 1598, UL 844
• Emergency battery pack, Suffix -EL ➊. • UL Listed: E10794
• Emergency battery pack capability in moments of power
interruption. Luminaire automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.

➊ Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1113


© September 2010
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

VRS: DRS:
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups F, G
Class III

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For VRS And DRS Non-Metallic Fluorescent Lighting Fixtures
VRS 2 40 BU EL

Series: Lamp Type: Options:


VRS - Vaportight 32 - 32 W,T8 (Electronic) EL - Emergency Battery Pack
DRS - Dust-Ignitionproof 40 - 40 W, (Electronic) F - Fuse
60 - 60 W, T12, HO 800 MA (48)

Number of Lamps Voltage:


2 - 2 Lamps BU - 120-277 V, 50/60 Hz
3 - 3 Lamps 347 - 347 V 60 Hz V

Technical Data: Thermal Performance of VRS and DRS Fixtures


Lamp
Ambient “T” Hazardous
Fixture Quantity Watt Type Temp °F/°C Numbers Classification
VRS232 2 32 265MA-RS 104/40 T-4A Class I, Division 2, Groups A,B,C,D
Lighting

VRS332 3 32 265MA-RS 104/40 T-4A Class I, Division 2, Groups A,B,C,D


VRS240 2 40 430MA-RS 104/40 T-4A Class I, Division 2, Groups A,B,C,D
VRS340 3 40 430MA-RS 104/40 T-4A Class I, Division 2, Groups A,B,C,D
VRS260 2 60 800MA-HO 77/25 T-3C Class I, Division 2, Groups A,B,C,D
DRS232 2 32 265MA-RS 77/25 T-6 Class II, Division 1 & 2 Groups F,G
DRS332 3 32 265MA-RS 77/25 T-6 Class II, Division 1 & 2 Groups F,G
Lighting: Enclosed and Gasketed — Area — Fluorescent

DRS240 2 40 430MA-RS 77/25 T-4 Class II, Division 1 & 2 Groups F,G
DRS340 3 40 430MA-RS 77/25 T-6 Class II, Division 1 & 2 Groups F,G
DRS260 2 60 800MA-HO 77/25 T-6 Class II, Division 1 & 2 Groups F,G

Vaportight Adjustable Hanger or Aligner – Iron Outlet Plugs


• Suitable for use in locations where equipment is exposed to the
deteriorating effects of non-combustible atmospheres containing
corrosive fumes, vapors, dust, smoke and/or moisture.
• Range of adjustment is 45°. Two-piece ball type cast iron body; gasket
sealed at the adjustable ball joint. Maximum overall length is 53-5/8
inches. Finish is baked white paint over electroplating.
• These iron plugs are for closing tapped outlets in explosion-proof
boxes. Plugs are electroplated and finished in baked aluminum paint.
A socket head is provided for square wrenches.

V CSA Certification Only.

1114 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

VRS: DRS:
Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups F, G
Class III

Number of Lamps ➋ Lamp Watts Lamp Type Unput Volts Freq. (Hz) Ballast Type Catalog Number
VRS 32 W, 40 W and 60 W Fixtures Furnished with 1/4” Clear Tempered Glass Lens ➊
2 32 T8 120-277 50/60 Electronic VRS232BU
2 40 T12 120-277 50/60 Electronic VRS240BU
2 60 T12 120-277 50/60 Electronic VRS260BU
3 32 T8 120-277 50/60 Electronic VRS332BU
3 40 T12 120-277 50/60 Electronic VRS340BU

DRS 32 W, 40 W and 60 W Fixtures Furnished with 1/4” Clear Tempered Glass Lens
2 32 T8 120-277 50/60 Electronic DRS232BU
2 40 T12 120-277 50/60 Electronic DRS240BU
2 60 T12 120-277 50/60 Electronic DRS260BU
3 32 T8 120-277 50/60 Electronic DRS332BU
3 40 T12 120-277 50/60 Electronic DRS340BU

Lighting
Lighting: Enclosed and Gasketed — Area — Fluorescent

OPTIONS: Add suffix -F for individually fused ballast. Add suffix -EL for emergency battery pack. (For 50Hz with -EL suffix, consult factory for certifications.)
➊ Consult factory for clear high-impact acrylic lens. UL Listed for Class I, Division 2, Groups. A, B, C, D; suitable for use in locations exposed to moisture or non-
combustible gases.
➋ Lamps not furnished with fixture.
➌ Low temperature ballast (-20 °F/-29 °C starting) provided as standard.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1115


© September 2010
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

Description Catalog Number


45° Adjustable Brackets

Two “L-type” brackets with gaskets – adjustable to 45°


DRKHN
in 5° increments for “custom” illumination spread.

45° Fixed Mounting Brackets

Two “L-type” brackets with gaskets for wall or ceiling


DRAGN
mounting – provides wide-spread illumination.

Angle Bars

Two heavy-duty bars with holes for chain suspension of


DRCXN
fixtures.
Lighting

Lens and Door Frame

Lens and door frame VRSLENS


Lens and door frame DRSLENS
Lighting: Enclosed and Gasketed — Area — Fluorescent

Sockets – Lampholders
32- and 40 Watt Fixed-end lampholder (Med. Bi-pin) VRSDRS40SS0C
32- and 40 Watt Plunger-end lampholder (Med. Bi-pin) VRSDRS40CS0C
60 Watt Fixed-end lampholder (High Output) VRSDRS60SS0C
60 Watt Plunger-end lampholder (High Output) VRSDRS60CS0C
Plunger Type Fixed Type * Each lamp has a Fixed and Plunger Lampholder
Hubs

Side and Top suspension hubs VRSDRSHUB

1116 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
VRS™ and DRS™ Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

Zone Lumens Total Luminaire Efficiency = 73.5%

0-10 145.72 CIE Type – Direct REPORT NUMBER: VRS232


10-20 421.76
Spacing
Lamps: Two 32 W Fluorescent Vaportightproof
20-30 651.35 Plane Criteria

30-40 798.47 0-180 1.28 Coefficients of Utilization - Zonal Cavity Method

40-50 824.90 90-270 1.34 Effective Floor Cavity Reflectance 0.20

50-60 701.76 Diagonal 1.44 % Ceiling Rcc 80 70 50 30 10 0

60-70 498.35 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 189.17 Zonal Lumen Summary 0 87 87 87 87 85 85 85 85 82 82 82 78 78 78 75 75 75 73

80-90 30.32 Zone Lumens % Lamp % Fixture 1 81 77 74 72 79 76 73 71 73 70 68 70 68 66 67 66 64 63


90-100 0.00 0-30 1218.83 21.0 28.6 2 74 68 63 59 72 66 62 58 64 60 57 62 58 56 59 57 55 53
100-110 0.00 0-40 2017.30 34.8 47.3 3 67 60 54 49 65 59 53 49 56 52 48 54 51 47 53 49 46 45
110-120 0.00 0-60 3543.96 61.1 83.2 4 62 53 47 42 60 52 46 42 50 45 41 49 44 41 47 43 40 38
120-130 0.00 0-90 4261.81 73.5 100.0 5 57 47 41 36 55 47 41 36 45 40 36 44 39 35 42 38 35 33
130-140 0.00 90-120 0.00 0.0 0.0 6 52 43 36 32 51 42 36 31 41 35 31 39 35 31 38 34 31 29
140-150 0.00 90-130 0.00 0.0 0.0 7 48 39 32 28 47 38 32 28 37 32 28 36 31 27 35 31 27 26
150-160 0.00 90-150 0.00 0.0 0.0 8 45 35 29 25 44 35 29 25 34 28 25 33 28 25 32 28 24 23
160-170 0.00 90-180 0.00 0.0 0.0 9 42 32 26 22 41 32 26 22 31 26 22 30 26 22 30 25 22 21
170-180 0.00 180-0 4261.81 73.5 100.0 10 39 30 24 20 39 29 24 20 29 24 20 28 23 20 27 23 20 19

Lighting
Zone Lumens Total Luminaire Efficiency = 70.1%

0-10 126.78 CIE Type – Direct REPORT NUMBER: VRS240


10-20 367.88 Lamps: Two 40 W Fluorescent Vaportightproof
Spacing

Lighting: Enclosed and Gasketed — Area — Fluorescent


20-30 567.43 Plane Criteria

30-40 693.10 0-180 1.28 Coefficients of Utilization - Zonal Cavity Method

40-50 715.79 90-270 1.32 Effective Floor Cavity Reflectance 0.20

50-60 620.48 Diagonal 1.42 % Ceiling Rcc 80 70 50 30 10 0

60-70 433.89 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 163.48 Zonal Lumen Summary 0 83 83 83 83 81 81 81 81 78 78 78 75 75 75 72 72 72 70

80-90 25.87 Zone Lumens % Lamp % Fixture 1 77 74 71 69 75 72 70 67 69 67 65 67 65 63 64 63 61 60


90-100 0.00 0-30 1062.10 20.0 28.6 2 70 65 60 56 68 63 59 56 61 57 54 59 56 53 57 54 52 51
100-110 0.00 0-40 1755.20 33.1 47.3 3 64 57 52 47 62 56 51 47 54 49 46 52 48 45 50 47 44 43
110-120 0.00 0-60 3091.47 58.3 83.2 4 59 51 45 40 57 50 44 40 48 43 39 46 42 39 45 41 38 37
120-130 0.00 0-90 3714.71 70.1 100.0 5 54 45 39 35 53 44 39 34 43 38 34 42 37 34 40 36 33 32
130-140 0.00 90-120 0.00 0.0 0.0 6 50 41 35 30 49 40 34 30 39 34 30 38 33 29 37 32 29 28
140-150 0.00 90-130 0.00 0.0 0.0 7 46 37 31 27 45 36 31 27 35 30 26 34 30 26 33 29 26 25
150-160 0.00 90-150 0.00 0.0 0.0 8 43 34 28 24 42 33 28 24 32 27 23 31 27 23 31 26 23 22
160-170 0.00 90-180 0.00 0.0 0.0 9 40 31 25 21 39 30 25 21 30 25 21 29 24 21 28 24 21 20
170-180 0.00 180-0 3714.71 70.1 100.0 10 38 28 23 19 37 28 23 19 27 23 19 27 22 19 26 22 19 18

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1117


© September 2010
DRS™ Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

Zone Lumens Total Luminaire Efficiency = 73.5%

0-10 145.72 CIE Type – Direct REPORT NUMBER: DRS232


10-20 421.76 Lamps: Two 32 W Fluorescent Dust-Ignitionproof
Spacing
20-30 651.35 Plane Criteria

30-40 798.47 0-180 1.28 Coefficients of Utilization - Zonal Cavity Method

40-50 824.90 90-270 1.34 Effective Floor Cavity Reflectance 0.20

50-60 701.76 Diagonal 1.44 % Ceiling Rcc 80 70 50 30 10 0

60-70 498.35 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 189.17 Zonal Lumen Summary 0 87 87 87 87 85 85 85 85 82 82 82 78 78 78 75 75 75 73

80-90 30.32 Zone Lumens % Lamp % Fixture 1 81 77 74 72 79 76 73 71 73 70 68 70 68 66 67 66 64 63


90-100 0.00 0-30 1218.83 21.0 28.6 2 74 68 63 59 72 66 62 58 64 60 57 62 58 56 59 57 55 53
100-110 0.00 0-40 2017.30 34.8 47.3 3 67 60 54 49 65 59 53 49 56 52 48 54 51 47 53 49 46 45
110-120 0.00 0-60 3543.96 61.1 83.2 4 62 53 47 42 60 52 46 42 50 45 41 49 44 41 47 43 40 38
120-130 0.00 0-90 4261.81 73.5 100.0 5 57 47 41 36 55 47 41 36 45 40 36 44 39 35 42 38 35 33
130-140 0.00 90-120 0.00 0.0 0.0 6 52 43 36 32 51 42 36 31 41 35 31 39 35 31 38 34 31 29
140-150 0.00 90-130 0.00 0.0 0.0 7 48 39 32 28 47 38 32 28 37 32 28 36 31 27 35 31 27 26
150-160 0.00 90-150 0.00 0.0 0.0 8 45 35 29 25 44 35 29 25 34 28 25 33 28 25 32 28 24 23
160-170 0.00 90-180 0.00 0.0 0.0 9 42 32 26 22 41 32 26 22 31 26 22 30 26 22 30 25 22 21
170-180 0.00 180-0 4261.81 73.5 100.0 10 39 30 24 20 39 29 24 20 29 24 20 28 23 20 27 23 20 19
Lighting

Zone Lumens Total Luminaire Efficiency = 70.1%

0-10 126.78 CIE Type – Direct REPORT NUMBER: DRS240


10-20 367.88 Lamps: Two 40 W Fluorescent Dust-Ignitionproof
Spacing
Lighting: Enclosed and Gasketed — Area — Fluorescent

20-30 567.43 Plane Criteria

30-40 693.10 0-180 1.28 Coefficients of Utilization - Zonal Cavity Method

40-50 715.79 90-270 1.32 Effective Floor Cavity Reflectance 0.20

50-60 620.48 Diagonal 1.42 % Ceiling Rcc 80 70 50 30 10 0

60-70 433.89 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80 163.48 Zonal Lumen Summary 0 83 83 83 83 81 81 81 81 78 78 78 75 75 75 72 72 72 70

80-90 25.87 Zone Lumens % Lamp % Fixture 1 77 74 71 69 75 72 70 67 69 67 65 67 65 63 64 63 61 60

90-100 0.00 0-30 1062.10 20.0 28.6 2 70 65 60 56 68 63 59 56 61 57 54 59 56 53 57 54 52 51


100-110 0.00 0-40 1755.20 33.1 47.3 3 64 57 52 47 62 56 51 47 54 49 46 52 48 45 50 47 44 43
110-120 0.00 0-60 3091.47 58.3 83.2 4 59 51 45 40 57 50 44 40 48 43 39 46 42 39 45 41 38 37
120-130 0.00 0-90 3714.71 70.1 100.0 5 54 45 39 35 53 44 39 34 43 38 34 42 37 34 40 36 33 32
130-140 0.00 90-120 0.00 0.0 0.0 6 50 41 35 30 49 40 34 30 39 34 30 38 33 29 37 32 29 28
140-150 0.00 90-130 0.00 0.0 0.0 7 46 37 31 27 45 36 31 27 35 30 26 34 30 26 33 29 26 25
150-160 0.00 90-150 0.00 0.0 0.0 8 43 34 28 24 42 33 28 24 32 27 23 31 27 23 31 26 23 22
160-170 0.00 90-180 0.00 0.0 0.0 9 40 31 25 21 39 30 25 21 30 25 21 29 24 21 28 24 21 20
170-180 0.00 180-0 3714.71 70.1 100.0 10 38 28 23 19 37 28 23 19 27 23 19 27 22 19 26 22 19 18

1118 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66 - IK09/10

Applications
• Designed for flush or surface mounting; most specifically
clean room environments where a seamless smooth ceiling
is mandatory.
• Typical applications include: the food industry, chemical
plants, pharmaceuticals and delicate electronic manufacturing
such as the aerospace industry.
• Ideal for rigorous corrosive environments, involving water,

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent


dust and extreme temperature variations.
• Can be installed in hazardous areas designated as Zone 4 x 18 W Surface Mounting
1, 2, 21 and 22.
Features
• One-piece welded steel housing with integral frame to
seal out contaminants.
• Allows recessed mounting in permanent ceilings from
55 mm to 130 mm (2" to 5" approximately).
• Frameless tempered (safety) 5 mm (1/4") thick lens.
Lens secured to housing by internal metallic hinges
and secured with captive 316L stainless steel screws,
allowing for easy lamp replacement and fixture maintenance.
• Positive safety switch and new Ex e battery with 2 x 36 W Recessed
plug-in connector for safety and easy maintenance
in hazardous locations.
• Designed for ease of installation and maintenance.
• Bi-pin G13 lampholder.
• Also available as surface mounting version.
• New ballast:
— EOL (End Of Life) protection in accordance to the latest EN
60079-7 standard Certifications and Compliances
— Multi-tap 110 to 254 Vac/Vdc +/-10% 50/60 Hz • Gas: Zones 1 and 2
— Two channel standard ballast (if one lamp fails the second — Conforming to ATEX 94/9/CE: CE 0081 II2 G
lamp remains in operation) — ATEX/IEC Protection: Ex de IIC/ Ex demb IIC (emergency
— Ex e plug-in connector for rapid and error free maintenance version)
— Self test on 3 hours duration emergency version — T Rating: T6 to T4 (see T Ratings on following page)
— High power factor electronic ballast (>0.95) • Dust: Zone 22
• Cable entries: — Conforming to ATEX 94/9/CE: CE 0081 II2 D
— Three clearance holes for M20 cable gland supplied with M20 — ATEX/IEC Protection: Ex tD A21
polyamide cable gland (cable dia. 0.26 to 0.57" / 6.5 to 14.5 — Surface Temperature: T167 °F /75 °C
mm) and M20 polyamide blanking plug as below quantity: • Ambient Temperature: -4 °F/-20 °C Ta 131 °F/55 °C

Lighting
— One M6 earth stud. • CE Declaration of Conformity: 50276
Standard Materials • ATEX Certificate: LCIE 07 ATEX 6104
• Housing and integral frame: one-piece, welded steel • IECEx Certificate: IECEx LCI 07.0019
• Safety lens: 0.20"/5 mm thick tempered • Index of Protection: IP66
• Gasket: Silicone, 4 lips, completely sealed and contained • Impact of Resistance: IK09 or IK10 depending on version
in the fixture • Ex standards :EN / IEC 60079-0; 60079-1; 60079-7; 60079-18
• Internal reflector: white polycarbonate multi-parabolic 61241-0; 61241-1
• Cable gland and blanking plug: polyamide • Product standards: EN / IEC 60598-1; 60598-2-22
• EMC standards: EN / IEC 55015; 61547
Standard Finishes • Other standards: EN / IEC 60529 (IP); 62262 (IK)
• Housing and integral frame: white powder epoxy paint
Options
• 316L stainless steel housing and integral frame, natural finish.
• Through wiring.
• White powder epoxy painted steel reflector.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1119


© September 2010
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66 - IK09/10

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FL Non-Metallic Fluorescent Lighting Fixtures
RE B 1 18 BU L E

Series: Wattage: Options:


RE - RE Series 18 - 18 Watt E - 3H Emergency (combined) - Battery
36 - 36 Watt 6 V - 4 Ah
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

58 - 58 Watt E1 - 1 H 30 Emergency (combined)


- Battery 6 V - 7 Ah
E7 - 3H Emergency (combined) -
Battery 6 V - 7 Ah
N - No switch ③
P - White painted steel internal
reflector ①
S - 316L Stainless steel housing)

Lamp Type: Voltage:


B - Bi-pin (G13) B3 - 100 to 130 Vac/Vdc
50/60 Hz
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz

Number of Lamps: Termination/Wiring:


1 - Single L - Loop In/Loop Out
2 - Double T - Through wired ②
3 - Three Lamps
4 - Four Lamps

T Ratings Termination and Wiring


Ambient Temperature • Terminal capacity: 0.006 in2/4 mm2 (flexible) or
Ceiling Position Wall Position 0.009in2/6 mm2 (solid).
• Loop in/Loop out: One terminal block ⑤
104 °F/ 122 °F/ 131 °F/ 104 °F/ 122 °F/ 131 °F/
— Standard version:
Version 40 °C 50 °C 55 °C 40 °C 50 °C 55 °C 2 (L) + 2 (N) + 2 (PE)
Lighting

2 x 18 W ④ T6 T5 T5 T5 T5 T4 — Emergency version:
2 (LP) + 2 (L) + 2 (N) + 2 (PE)
2 x 18 W Emergency ④ T5 T4 T4 T5 T5 T4 • Through wired: Two terminal blocks (one at each
3 x 18 W T5 T4 T4 T4 T4 T4 end) ⑤
— Standard version:
4 x 18 W T5 T4 T4 T5 T4 T4 2 (L) + 2 (N) + 2 (PE)
T5 T4 T4 T5 T4 T4 1 (L) + 1 (N) + 1 (PE)
2 x 36 W ④
— Emergency version:
2 x 36 W Emergency ④ T5 T4 T4 T5 T4 T4 2 (LP) + 2 (L) + 2 (N) + 2 (PE)
1 (LP) + 1 (L) + 1 (N) + 1 (PE)
3 x 36 W T4 T4 T4 T4 T4 T4
4 x 36 W T5 T4 T4 T5 T4 T4 Nickel
2 x 58 W ④ T4 T4 T4 T4 T4 T4 Plated
Blanking Brass
2 x 58 W Emergency ④ T4 T4 T4 T4 T4 T4 Version Cable Gland Plug Locknut
3 x 58 W T4 T4 T4 T4 T4 T4 Loop 1 1 3
4 x 58 W T4 T4 T4 T4 T4 T4 Through 2 1 3
① As standard for 18 W emergency version and 4 lamp version.
② T/W and Loop in/Loop out - 3 cores (single phase).
③ Only for standard versions.
④ T rating for single lamp version is the same as twin lamp version.
⑤ PE: Earth; N: Neutral. L: Live. LP: Permanent Live for emergency version.

1120 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66 - IK09/10

Recessed — 110/254 Vac/Vdc 50/60 Hz — Front access — White Painted Steel Housing
Version Wiring Reflector Weight (lbs/kg) Volume (in3/dm3) Catalog Number
Standard Version — Bi-pin Lamps (G13)
2 x 18 W Loop Polycarbonate 30.86/14 3905.52/64 REB218BUFL
2 x 18 W Through Polycarbonate 30.86/14 3905.52/64 REB218BUFT
4 x 18 W Loop White Painted Steel 46.30/21 5675.21/93 REB418BUFLP

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent


4 x 18 W Through White Painted Steel 46.30/21 5675.21/93 REB418BUFTP
2 x 36 W Loop Polycarbonate 41.89/19 6590.56/108 REB236BUFL
2 x 36 W Through Polycarbonate 41.89/19 6590.56/108 REB236BUFT
4 x 36 W Loop White Painted Steel 63.93/29 9641.75/158 REB436BUFLP
4 x 36 W Through White Painted Steel 63.93/29 9641.75/158 REB436BUFTP
2 x 58 W Loop Polycarbonate 48.50/22 7933.09/130 REB258BUFL
2 x 58 W Through Polycarbonate 48.50/22 7933.09/130 REB258BUFT
4 x 58 W Loop White Painted Steel 70.55/32 11594.51/190 REB458BUFLP
4 x 58 W Through White Painted Steel 70.55/32 11594.51/190 REB458BUFTP
3 Hours Emergency Version — Bi-pin Lamps (G13)
2 x 18 W Loop Polycarbonate 30.86/14 3905.52/64 REB218BUFLEP
2 x 18 W Through Polycarbonate 30.86/14 3905.52/64 REB218BUFTEP
4 x 18 W Loop White Painted Steel 46.30/21 5675.21/93 REB418BUFLEP
4 x 18 W Through White Painted Steel 46.30/21 5675.21/93 REB418BUFTEP
2 x 36 W Loop Polycarbonate 41.89/19 6590.56/108 REB236BUFLE
2 x 36 W Through Polycarbonate 41.89/19 6590.56/108 REB236BUFTE
4 x 36 W Loop White Painted Steel 63.93/29 9641.75/158 REB436BUFLEP
4 x 36 W Through White Painted Steel 63.93/29 9641.75/158 REB436BUFTEP
2 x 58 W Loop Polycarbonate 48.50/22 7933.09/130 REB258BUFLE
2 x 58 W Through Polycarbonate 48.50/22 7933.09/130 REB258BUFTE
4 x 58 W Loop White Painted Steel 70.55/32 11594.51/190 REB458BUFLEP
4 x 58 W Through White Painted Steel 70.55/32 11594.51/190 REB458BUFTEP
For non-recessed lighting, please replace letter “F” with letter “M” as per Catalog number logic. Example: REB218BUFL becomes REB218BUML.

Lighting
Accessories
Description Weight (lbs/kg) Catalog Number
Fixing Brackets - Set of four.
Zinc plated steel 1.32/0.60 REFBST
316 stainless steel 1.32/0.60 REFBSS

Ceiling Mounting Brackets - Set of two


Zinc plated steel 4.41/2.00 RECMST
316 stainless steel 4.41/2.00 RECMSS
M8 Eye Bolts - Set of four
Zinc plated steel 0.55/0.25 REEBST
316 stainless steel 0.55/0.25 REEBSS

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1121


© September 2010
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66 - IK09/10

Wiring Diagram Emergency Function Diagram


Mains Two Lamp Version
PE N L Mains Lighting Switch ON Lighting Switch OFF
Lighting
Switch
ON
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

L’

OFF
U
Standard Fluorescent
N Lighting Fixture
PE Three Lamp Version

Mains Lighting Switch ON Lighting Switch OFF

ON
U’
U Emergency Fluorescent
N Lighting Fixture
PE
OFF

LED Status
Color Indication Function
LED glows Batteries are connected
Green
LED blinks Batteries are charged
Lighting

Red LED blinks Batteries are not connected or defect


Yellow LED blinks Batteries are charging and discharging during automatic cycle

Emergency Light Duration


Version Battery Capacity Duration Light Output
2 x 18 W 4 Ah – 6 V 3 hours 45%
4 Ah – 6 V 3 hours 15%
2 x 36 W
7 Ah – 6 V 3 hours 25%
4 Ah – 6 V 3 hours 9%
2 x 58 W
7 Ah – 6 V 3 hours 15%

1122 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
RE Series Recessed Fluorescent Luminaire Dimensions
Standard and Emergency Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66 - IK09/10

Dimensions in Inches/Millimeters

Recessed Surface Mounting

A A

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent


B B

C D C D

134.5 mm
132.5 mm

5.30”/
5.23”/

0.08”/
E E
2.0 mm

4 x Ø 0.33”/8.5 mm F 4 x Ø 0.33”/8.5 mm F

Ceiling Cut-out

Versions A B C D E F G H

Lighting
18 W (1, 2, 3 lamps) 32.52/826 12.60/320 10.63/270 30.55/776 15.35/390 7.24/184 30.94/786 11.02/280
18 W (4 lamps) 32.52/826 19.29/490 17.32/440 30.55/776 15.35/390 13.94/354 30.94/786 17.72/450
36 W (1, 2, 3 lamps) 56.54/1436 12.60/320 10.63/270 54.57/1386 39.37/1000 7.24/184 54.96/1396 11.02/280
36 W (4 lamps) 56.54/1436 19.29/490 17.32/440 54.57/1386 39.37/1000 13.94/354 54.96/1396 17.72/450
58 W (1, 2, 3 lamps) 68.35/1736 12.60/320 10.63/270 66.38/1686 51.18/1300 7.24/184 66.77/1696 11.02/280
58 W (4 lamps) 68.35/1736 19.29/490 17.32/440 66.38/1686 51.18/1300 13.94/354 66.77/1696 17.72/450

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1123


© September 2010
RE Series Recessed Fluorescent Luminaire Photometric Data
Standard and Emergency Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66 - IK09/10

Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal


Transverse
Luminaire symbol according to NF C 71-121
1 x 18 W
2 x 18 W 3 x 18 W
Efficiency 67.1% Efficiency 62% Efficiency 61.2%
NF C 71-121: 0.67 E NF C 71-121: 0.62 E NF C 71-121: 0.61 E

Candela Distribution Candela Distribution Candela Distribution


0-180 90-270 0-180 90-270 0-180 90-270
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

0 209 209 0 205 205 0 201 201


5 208
Degrees 208 5 204
Degrees 203 5 200
Degrees 201

10 205 208 90° 10 202 203 90° 10 197 201 90°

15 201 207 75° 15 197 202 75° 15 193 200 75°


20 194 205 20 191 201 60° 20 187 197 60°
60°
25 186 203 25 182 201 25 179 195
30 176 201 45° 30 173 200 30 169 192
45° 45°
35 164 197 35 161 192 35 158 189
40 151 192 40 148 183 40 145 181
45 136 185 45 133 177 45 131 170
30° 30° 30°
50 120 177 50 117 173 50 115 155
55 102 164 55 99 168 55 98 132
60 83 141 0° 15° 60 80 168 0° 15° 60 80 107 0° 15°
65 63 115 65 61 163 65 61 80
70 43 77 70 41 154 70 41 53

2 x 18 W 4 x 18 W
Efficiency 60.5% Efficiency 63.7%
NF C 71-121: 0.60 F NF C 71-121: 0.63 E
Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270
0 196Degrees 196 0 194Degrees 194

5 195 196 90° 5 193 194 90°


10 193 195 75° 10 191 195 75°
15 189 195 15 186 195
20 183 193 60° 20 181 193 60°
25 175 191 25 173 192
30 166 187 45° 30 164 190 45°
35 155 182 35 153 185
40 143 174 40 141 179
45 129 162 45 128 171
50 114 147 50 113 160
Lighting

30° 30°
55 98 131 55 96 146
60 79 109 60 78 127
65 60 85 0° 15° 65 60 106 0° 15°
70 40 62 70 40 82

4 x 36 W
Efficiency 61.5%
NF C 71-121: 0.61 E
Candela Distribution
0-180 90-270
0 190 190
Degrees
5 289 190 90°
10 287 190
75°
15 183 189
20 177 188 60°
25 170 186
30 162 182
45°
35 151 178
40 139 172
45 126 163
50 111 152 30°
55 96 138
60 78 121
0° 15°
65 60 102
70 42 80

1124 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
RE Series Recessed Fluorescent Luminaire Photometric Data
Standard and Emergency Back-Up. Increased Safety

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66 - IK09/10

Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal


Transverse
Luminaire symbol according to NF C 71-121
1 x 36 W 2 x 36 W 3 x 36 W
Efficiency 64.4% Efficiency 64.8% Efficiency 63.7%
NF C 71-121: 0.64 E NF C 71-121: 0.64 E NF C 71-121: 0.63 F

Candela Distribution Candela Distribution Candela Distribution


0-180 90-270 0-180 90-270 0-180 90-270

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent


0 196 196 0 198 198 0 207 207
5 195Degrees 196 5 197Degrees 198 5 207Degrees 208
10 192 196 90° 10 194 198 90° 10 204 208 90°
15 188 194 75° 15 190 197 75° 15 199 206 75°
20 182 192 20 184 196 20 193 204
60° 60° 60°
25 174 189 25 176 195 25 185 202
30 165 188 30 167 195 45° 30 175 200 45°
45°
35 154 185 35 156 194 35 164 196
40 152 181 40 144 191 40 151 189
45 129 176 30° 45 130 184 30° 45 136 178 30°
50 114 170 50 115 172 50 120 162
55 97 159 55 98 154 55 103 139
0° 15° 0° 15° 0° 15°
60 80 143 60 80 129 60 84 112
65 61 116 65 62 101 65 65 83
70 43 76 70 43 72 70 45 55

1 x 58 W 2 x 58 W 3 x 58 W
Efficiency 64.9% Efficiency 61.8% Efficiency 57.8%
NF C 71-121: 0.65 E NF C 71-121: 0.62 E NF C 71-121: 0.58 E
Candela Distribution Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270 0-180 90-270
0 189 Degrees189 0 182 Degrees182 0 185 Degrees185
5 188 189 90° 5 182 183 90° 5 185 185 90°
10 187 188 10 181 183 10 183 185
75° 75° 75°
15 184 187 15 178 182 15 181 184
20 181 186 60° 20 174 182 60° 20 177 182 60°
25 176 185 25 170 182 25 172 180
30 170 185 45° 30 164 181 45° 30 166 178 45°
35 162 184 35 156 181 35 159 174
40 150 180 40 145 178 40 147 168
45 136 175 45 131 172 45 133 158
50 119 169 30° 50 116 162 30° 50 118 144 30°

Lighting
55 102 162 55 99 148 55 100 125
60 83 146 60 81 126 60 82 101
0° 15° 0° 15° 0° 15°
65 63 122 65 52 99 65 63 75
70 43 85 70 43 70 70 43 49

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1125


© September 2010
Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

Applications
• Enclosed and gasketed lighting fixtures for use in storage
areas, tunnels, subways, chemical plants and other areas where
moisture, dirt or corrosive atmospheres are a problem.
• Suitable for use in wet locations.
• Standard fixtures designed for 60 to 300 Watt medium base
incandescent lamps.
• Pendant, feed-thru, ceiling, stanchion and wall mounts available.
• Ventilated steel reflectors with white porcelain finish are
available for standard applications. Fiberglass reinforced
polyester reflectors are designed for installations where fixture
is subject to severe corrosive conditions or vandalism.
Features
• Modern styling, with clean-line mounting hood and prismatic
glass globe, plus optional guard.
• Prismatic globe, furnished as standard, eliminates glare
and distributes light evenly.
• Globe seats firmly against composition gasket in mounting Illustrated Features
hood to keep out dirt and moisture. Full threads eliminate Mounting Hood
“cross threading.” Pendant style shown has setscrew to prevent
• Fixture is complete with gaskets and socket. Socket is shock- fixture stem from turning. Other styles include
absorbing to prolong lamp life and can be easily removed for stanchion, ceiling and wall mounting.
Lighting: Enclosed and Gasketed — Area — Incandescent

wiring without tools.


• Porcelain socket construction assures long trouble-free Shock-Absorbing Medium Base Socket
operation in high ambient installations. Spring absorbs vibration to prolong lamp
• Both porcelain steel and polyester reflectors are secured to life. Porcelain construction for trouble-free
mounting hoods with screws (furnished). operation in high ambient installations.
• Guards have exclusive snap-on attachment feature for quick Globe
installation and fast servicing. Attractive, tapered prismatic glass globes
• Choice of reflector styles: for glare elimination and uniform light
(1) steel reflector with white porcelain enamel in standard dome distribution. Colors available – also
and 30º angle vandal-resistant plastic globes. Globe seats
(2) fiberglass reinforced polyester reflector in standard dome firmly against gasket to exclude moisture, dirt
and 30º angle. and vapors.
• Maximum input voltage 277 V (suitable for DC applications).
Guard
Standard Materials Snap-on guards (and reflectors) – simply
• Mounting hoods: copperfree (4/10 of 1% max.) aluminum snap-in and twist. Spring action balls snap
• Guards: pressure cast copperfree (4/10 of 1% max.) aluminum into detents of fixture body.
• Reflectors: porcelain steel or fiberglass reinforced polyester Guard and Reflectors
• Socket: porcelain with brass screw shell
• Globes: prismatic glass
Standard Finishes
• Mounting hoods and guards: epoxy powder coat
• Steel reflectors: baked white porcelain enamel
• Fiberglass reinforced polyester reflectors: natural finish
• Socket and globes: natural finish
Options
• To order fixture with other than standard clear glass globe, add
Lighting

suffix letters to catalog number as indicated in table, and adjust


difference in price.

Color Glass Globe Plastic Globe


Amber -AM -PAM
Certifications and Compliances
Blue -BL -PBL
• UL Standard: UL 1598, UL 844
Green -GR -PGR • UL Listed: E10444
Red -RE -PRE • CSA Standard: C22.2 No. 250, C22.2 No. 137
Clear Heat-Resistant -HR — • CSA Certified: 025428

V CSA Certification only.

1126 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Stylmaster™ Incandescent Luminaire Thermal Suitability
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

Class I, Division 2, Groups A, B, C, D


Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition
temperature of the atmosphere in which fixture is installed.

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
Supply Wire: 392 ºF/200 ºC

“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101-
Range 86-100 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120
(˚ºC)

Class I, Division 2, Groups A, B, C, D

VPGL-1HR (60-200 W) VPGL-2HR (200-300 W)


A-21 A-21 A-23 A-23 PS-25 PS-30 PS-25 PS-30

Lighting: Enclosed and Gasketed — Area — Incandescent


Reflector 100 W 150 W 200 W 200 W 200 W 200 W 300 W 300 W
None T3 T2D T2C T2C T2C T2C 325 325
Standard Dome T2D T2D T2B T2B T2B T2C 325 325
30º Angle T2D T2C T2B T2B T2B T2B 325 325

Fixture Ambient Suitability:


Fixture Ambient Suitability: Class II, Groups E, F, G; Class III; Enclosure 4X
Areas ºF ºC Fixture Watts
Non-Classified 392 200 A-23 60 to 300
Classified 104 40 PS-30 60 to 300

Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1127


© September 2010
Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

NEC Catalog Numbers CSA Catalog Numbers V


Lamp Hub Size With Globe With With Globe With
Without Guard With Guard Type Watts (Inches) and Guard Globe Only and Guard Globe Only
Pendant — 3/4” tapped opening — Furnished with 3/4” to 1/2” reducer
A-23 60-200 1/2 or 3/4 VPA1075G VPA1075 VCA1075G VCA1075

PS-30 200-300 1/2 or 3/4 VPA2075G VPA2075 VCA2075G VCA2075

Ceiling – Five Tapped Openings — With mounting lugs and four close-up plugs
1/2 VPX1050G VPX1050 — —
A-23 60-200
3/4 VPX1075G VPX1075 VCX1075G VCX1075
Lighting: Enclosed and Gasketed — Area — Incandescent

1/2 VPX2050G VPX2050 — —


PS-30 200-300
3/4 VPX2075G VPX2075 VCX2075G VCX2075

Ceiling – Outlet Box Mounting — Fits SEH ➊ or VPJB cast outlet box, or 4” octagonal outlet box — Furnished with screws and
gasket — Octagonal outlet boxes for non-classified areas only
A-23 60-200 3/4 VPOB10G VPOB10 VCOB10G VCOB10

PS-30 200-300 3/4 VPOB20G VPOB20 VCOB20G VCOB20

45˚ Stanchion – 1-1/4” Conduit


A-23 60-200 1-1/4 VPAN10125G VPAN10125 VCAN10125G VCAN10125

PS-30 200-300 1-1/4 VPAN20125G VPAN20125 VCAN20125G VCAN20125


Lighting

➊ Order SEH box from catalog Fittings Section, 4” octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section.
V CSA Certification only.

1128 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

NEC Catalog Numbers CSA Catalog Numbers V


Lamp Hub Size With Globe With With Globe With
Without Guard With Guard Type Watts (Inches) and Guard Globe Only and Guard Globe Only
Wall – Body includes outlet box with five tapped openings — With mounting lugs and four close-up plugs
1/2 VPWB1050G VPWB1050
A-23 60-200
3/4 VPWB1075G VPWB1075 VCWB1075G VCWB1075

1/2 VPWB2050G VPWB2050


PS-30 200-300
3/4 VPWB2075G VPWB2075 VCWB2075G VCWB2075

Wall – Outlet Box Mounting — Fits SEH ➊ or VPJB cast outlet box, or 4” octagonal outlet box — Furnished with screws and gasket
— Octagonal outlet boxes for non-classified areas only
A-23 60-200 VPOBW10G VPOBW10 VCOBW10G VCOBW10

PS-30 200-300 VPOBW20G VPOBW20 VCOBW20G VCOBW20

Lighting: Enclosed and Gasketed — Area — Incandescent


Wall – Outlet Box Mounting with Side Hubs — With two side hubs and one close-up plug
A-23 60-200 3/4 — — VCW1075G VCW1075

PS-30 200-300 3/4 — — VCW2075G VCW2075

Lighting

➊ Order SEH box from catalog Fittings Section, 4” octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1129


© September 2010
Stylmaster™ Incandescent Luminaire Accessories
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Catalog Numbers
Hub Size
Description (Inches) NEC CSA V
Pendant

Furnished with setscrew, 3/4” to 1/2” reducer for 1/2”


VPA75 VCA75
stem, medium base socket.

Ceiling – Five Tapped Openings

1/2 VPX50 VCX50


Four close-up plugs
3/4 VCX75

45º Stanchion
1-1/4 VPAN125 VCAN125
Lighting: Enclosed and Gasketed — Area — Incandescent

Wall – Five Tapped Openings in Outlet Box ➊


Four close-up plugs

1/2 VPWB50 —

3/4 VPWB75 —
Cast Outlet Box Only – Five Tapped Openings
Four close-up plugs. No socket. Fits VPOB, VPOBW
and VPWB.
1/2 VPJB50 VCJB50

3/4 VPJB75 VCJB75


Ceiling – For Outlet Box
(Octagonal outlet boxes for non-classified areas only)

Fits SEH or VPJB cast outlet box, or 4” octagonal outlet VPOB1 VCOB1
box. With screws and gasket.

Wall – For Outlet Box ➊


(Octagonal outlet boxes for non-classified areas only)

Fits SEH or VPJB cast outlet box, or 4” octagonal outlet


VPOBW1 VCOBW1
box. With screws and gasket.

Wall – Outlet Box Mounting with Side Hubs — With two side hubs and one close-up plug
Lighting

(Octagonal outlet boxes for non-classified areas only)

3/4 — VCB75

➊ Use 30º angle reflectors for wall installations – center line of fixture must be located at least 5-3/4” away from wall. Has four 3/16” dia. mounting holes located
90º apart on a 3-1/2” dia. center.
V CSA Certification only.

1130 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Stylmaster™ Incandescent Luminaire Accessories
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Catalog Numbers
Type Lamp Watts Color Glass Polycarbonate
Glass and Polycarbonate Globes ➊
Clear — VPGL-2PL
Clear Heat-Resistant VPGL-1HR —
Amber VPGL-1AM VPGL-2AMPL
A-23 60-200
Blue VPGL-1BL VPGL-2BLPL

Glass Globe Polycarbonate Globe Green VPGL-1GR VPGL-2GRPL


(VPGL-1HR) (VPGL-2PL) Red VPGL-1RE VPGL-2REPL
Glass Globes
200-300 Clear — —
Clear Heat-Resistant VPGL-2HR —
Amber VPGL-2AM —
PS-30
Blue VPGL-2BL —
Green VPGL-2GR —
Glass Globe (VPGL-2HR) Red VPGL-2RE —

Lighting: Enclosed and Gasketed — Area — Incandescent


Coated Tuff-Skin ® † Glass Globes Contains globe safely even if glass is broken

Heat-Resistant VPGL-2HRT —

VPGL-2HRT
Catalog Numbers
Type Lamp Watts
NEC CSA V
Guards
A-23 60-200 VPGU-1 VCFGU-1
PS-30 200-300 VPGU-2 VCFGU-2

VPGU-1 VPGU-2
Replacement Porcelain Shock-Absorbing Sockets
A-23 60-200
VPLR-123 VCLR-1
PS-30 200-300
Lighting

Medium Base
Replacement Gasket for Globes

Neoprene – for all Stylmaster globes VPGL-GK VCGL-GK


Globe Gasket
† Registered trademark of Thomas Manufacturing Corporation, Parkton, Md.
➊ Shatter-resistant for use in food processing plants, canneries, dairies, breweries, bakeries or anywhere broken glass would prove a hazard. Ideally suited for
areas where vandalism, high replacement and high maintenance costs are a problem. CAUTION: Use maximum 200 W lamp less reflector, 100 W max. with
reflector or colored globe. Do not use in ambients exceeding 25 ºC/77 ºF. For burning in vertical base-up position only.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1131


© September 2010
Stylmaster™ Incandescent Luminaire Reflectors and Accessory Weights
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Catalog Number
Description Porcelain Steel Polyester

Standard Dome Reflector LPR-25ST LPRP-25ST

30º Angle Reflector LPR-25AN LPRP-25AN

Weights
Typical Mounting Hoods
Lighting: Enclosed and Gasketed — Area — Incandescent

Pendant lbs/kg Ceiling lbs/kg Wall lbs/kg Stanchion lbs/kg


VPA75 VPX75 VPOBW10 VPAN-125
2/0.9 2/0.9 3/1.4 3/1.4
VCA75 VCX75 VCOBW10 VCAN-125

Globes and Guards Reflectors


Standard
Type Globe lbs/kg Guard lbs/kg Dome lbs/kg 30˚º Angle lbs/kg
60-200 W VPGL-1 2/0.9 VPGU-1 1/0.5 LPR-25ST 3/1.4 LPR-25AN 2/0.9
200-300 W VPGL-2 3/1.4 VPGU-2 1/0.5 LPRP-25ST 2/0.9 LPRP-25AN 2/0.9
Lighting

1132 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Stylmaster™ Incandescent Luminaire Dimensions
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Pendant Mount ➊ 45° Stanchion Mount ➊➋

7.00"/ 10.55"/268.0 mm
177.8 mm 12.08"/306.8 mm
9.23"/
234.4 mm 11.19"/
3.00"/ 3.00"/ 284.2 mm
76.2 mm 76.2 mm

151.4 mm
174.8 mm
6.52"/

191.0 mm
5.96"/
6.08"/

6.88"/

7.52"/
165.6 mm 154.4 mm 8.08"/

213.4mm
8.52"/ 205.2 mm

8.40"/
216.4 mm

Ceiling Outlet Box Mount Ceiling Mount for Junction Box Wall Mount with Junction Box Wall Outlet Box Mount
7.00"/ 7.00"/ 7.13"/ 5.25"/
177.8 mm 177.8 mm 181.1 mm 3.50"/ 133.4 mm
88.9 mm
4.06"/
4.00"/ 1.68"/ 103.1 mm 3.31"/ 4.00"/
101.6 mm 3.31"/

Lighting: Enclosed and Gasketed — Area — Incandescent


101.6 mm 42.7 mm † 84.1 mm †
84.1 mm
3.56"/
90.4 mm † 0.19”/4.8 mm
10.63"/ Dia. Mtg. Hole 8.75"/
270.0 mm 222.3 mm

Junction Box Mounting Body


0.33"/8.4 mm R
(+ DFT) (2 PLACES)
0.13"/3.3 mm R. Max
(8 Places)
0.22"/5.6 mm R
(+ DFT) (2 PLACES)

1.88"/
47.8 mm
40
.1
m 1.5 4.00"/
m 8
Di "/ 101.6 mm
a.
91

88 3 m D 0"/ +2
3. m / 2"

+
.4

.9 .6 ia
50 B

DF
4
10

m
m .0 ia /

"/ .C

T
1.
6

0" . -
m 4.7 7 m
4
m 5" m
D
12
0.

D FT
"D
FT

Lighting

➊ Height of hood is measured to bottom of flange. Height of globe and guard is from bottom of flange.
➋ Dimensions of angle are from center of pipe. Height is measured from pipe stop in stanchion hood.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1133


© September 2010
Stylmaster™ Incandescent Luminaire Dimensions
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Without Reflector Effective Floor Cavity Reflectance (Rfc) is 20%


% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .739 .689 .645 .684 .640 .598 .583 .548 .517 .489 .464 .439 .404 .384 .365 .322
2 .618 .548 .489 .572 .509 .456 .484 .435 .391 .403 .365 .331 .329 .299 .273 .234

ROOM CAVITY RATIOS


3 .527 .449 .386 .487 .416 .360 .411 .355 .308 .340 .297 .259 .275 .240 .210 .176

4 .460 .378 .316 .425 .351 .294 .358 .299 .253 .297 .250 .212 .239 .202 .172 .140
5 .398 .319 .258 .370 .296 .240 .313 .252 .206 .258 .209 .172 .208 .169 .138 .110
6 .353 .273 .216 .325 .253 .199 .274 .215 .170 .227 .178 .141 .183 .143 .112 .087
7 .312 .234 .181 .288 .216 .167 .242 .183 .141 .199 .152 .116 .161 .122 .092 .069
8 .279 .204 .152 .257 .189 .142 .217 .161 .120 .180 .133 .099 .144 .106 .077 .056
9 .251 .179 .130 .232 .166 .121 .196 .141 .102 .162 .116 .083 .130 .092 .065 .045

10 .226 .157 .112 .208 .146 .104 .177 .124 .087 .146 .102 .070 .118 .081 .054 .037

Standard Dome Effective Floor Cavity Reflectance (Rfc) is 20%


% Ceiling Rcc 80 70 50 30 10 0
Lighting: Enclosed and Gasketed — Area — Incandescent

% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .777 .747 .719 .759 .731 .706 .724 .701 .681 .693 .676 .658 .666 .650 .636 .620
2 .679 .631 .589 .665 .620 .583 .636 .599 .566 .610 .580 .552 .587 .561 .537 .521
ROOM CAVITY RATIOS

3 .593 .534 .486 .581 .525 .481 .557 .510 .471 .535 .495 .461 .514 .480 .451 .435
4 .523 .459 .409 .513 .453 .405 .492 .440 .398 .473 .428 .391 .456 .416 .384 .367
5 .459 .391 .340 .449 .385 .337 .433 .376 .334 .416 .366 .328 .401 .358 .323 .307
6 .406 .337 .289 .397 .333 .285 .382 .325 .282 .368 .317 .278 .356 .310 .274 .259
7 .359 .291 .246 .352 .287 .242 .339 .279 .238 .326 .274 .235 .316 .269 .232 .217
8 .323 .257 .211 .316 .254 .210 .305 .248 .208 .295 .243 .205 .284 .238 .203 .188
9 .291 .227 .182 .286 .223 .182 .275 .219 .180 .266 .214 .178 .257 .210 .175 .161
10 .262 .200 .159 .257 .199 .159 .249 .194 .157 .240 .290 .154 .234 .187 .152 .140

30° Angle
Photometric data shown on this page is based on a 200 Watt A-23 lamp
and is representative of the performance for all Stylmaster incandescent
fixtures. For candlepower values of fixtures with other lamps, multiply the
given candlepower values by the following multipliers: for 75 W A19 – 0.31;
for 100 W A19 – 0.45; for 150 W A21 – 0.75; and for 300 W PS25 – 1.65.
For candlepower values of fixtures with guard, multiply by 0.90.
Lighting

1134 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Applications
• Enclosed and gasketed lighting fixtures for use in storage
areas, tunnels, subways, chemical plants and other areas where
moisture, dirt or corrosive atmospheres are a problem.
• Suitable for use in wet locations.
• Standard fixtures designed for 60 to 300 W medium base
incandescent lamps.
• Available in pendant, 45º stanchion, and a variety of ceiling
and wall mountings.
Features
• Furnished with connection block for easy wiring.
• Unitized construction reduces installation and
maintenance costs.
• Shock-absorbing porcelain socket for longer lamp life.
• Neoprene rubber ring in neck of reflector snaps into groove Illustrated Features
of mounting hood – protects against vibration and chipping.
• Guard snaps into two recesses of adapter – no clamps Cut-Away View
or setscrews. Connection block is easily removed (loosen
• Available in three standard fixtures: two screws) to permit quick wiring.
(1) V-51 malleable iron mounting hood with aluminum adapter
and guard Mounting Hood
(2) all malleable iron (steel guard)

Lighting: Enclosed and Gasketed — Area — Incandescent


Available in pendant (shown), ceiling, wall
(3) all aluminum and 45º stanchion. Pendant has setscrew to
• Maximum input voltage 150 V. prevent fixture from turning on stem.
Standard Materials Neoprene Ring
• Mounting hoods: malleable iron or copperfree (4/10 of 1% Neoprene attachment ring secures reflector to
max.) aluminum mounting hood – no tools needed.
• Globe adapters: malleable iron or pressure cast copperfree Globe Adapter
(4/10 of 1% max.) aluminum When adapter is threaded onto mounting
• Socket: porcelain with brass screw shell hood, the socket makes electrical contact with
• Globes: glass. Optional globes in polycarbonate plastic connection block in mounting hood. Available
100 W Max in malleable iron (VAD-1M and VAD-2M) or
• Guards: steel or pressure cast copperfree (4/10 of 1% max.) aluminum (VAD-1 and VAD-2).
aluminum Porcelain Enamel Reflectors
• Reflectors: porcelain enamel steel Standard and 30° angle.
Standard Finishes Guard
Two sealed ball plunger units snap quickly,
• Malleable iron mounting hood and globe adapter: triple coat – easily and securely into cavities of globe
(1) zinc electroplate, (2) chromate, and (3) epoxy powder coat adapter. Guard can be used with or without a
• Aluminum mounting hood, adapter and guard: epoxy powder reflector.
coat
• Steel guard: zinc electroplate Guard and Reflectors
• Steel reflectors: white porcelain enamel
• Socket and globes: natural finish
Options
• To order fixture with other than standard clear glass globe, add
suffix letters to catalog number as indicated in table, and adjust
difference in price.
Lighting

Color Glass Globe Plastic Globe


Amber -AM -PAM
Blue -BL -PBL
Certifications and Compliances
Green -GR -PGR
• UL Standard: UL 1598, UL 844
Red -RE -PRE • UL Listed: E10444
Clear Heat-Resistant -HR — • CSA Standard: C22.2 No. 250, C22.2 No. 137
• CSA Certified: 025428

† 300 W PS-25 NOT approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1135


© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Class I, Division 2, Groups A, B, C, D


Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition
temperature of the atmosphere in which fixture is installed.

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
Supply Wire: 257 ºF/125 ºC

“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101-
Range 86-100 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120
(˚ºC)

Class I, Division 2, Groups A, B, C, D

60-150 W 200-300 W
A-21 PS-25 PS-30 PS-30
Lighting: Enclosed and Gasketed — Area — Incandescent

Reflector 100 W 150 W 200 W 300 W


None T3 T2D T2C 325
Standard Dome T2D T2C T2B 325
30º Angle T2C T2C T2B 325

Fixture Ambient Suitability: Fixture Ambient Suitability:


Class I, Division 2, Groups A, B, C, D Class II, Groups E, F, G; Class III; Enclosure 4X
Areas ºF ºC Fixture Watts
Non-Classified 167 75 A-23 60 to 300
Classified 104 40 PS-30 60 to 300
Lighting

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
V CSA Certification only.

1136 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Malleable Mounting Malleable Mounting Catalog Numbers ①


Hood, Aluminum Hood, Adapter Lamp Size Malleable Mounting Hood All Malleable All Aluminum
Adapter and Guard and Guard Type Watts (Inches) with Aluminum Guard with Guard with Guard
Pendant
1/2 VA1050G VA1050G-M VA1050G-A
3/4 VA1075G VA1075G-M VA1075G-A
A-21 60-150
1 VA1100G VA1100G-M —
1-1/4 VA1125G VA1125G-M —
1/2 VA2050G VA2050G-M VA2050G-A
3/4 VA2075G VA2075G-M VA2075G-A
PS-30 150-300
1 VA2100G VA2100G-M —
1-1/4 VA2125G VA2125G-M —

Ceiling — Five Tapped Openings — Four close-up plugs


1/2 VXHA1050G VXHA1050G-M VXHA1050G-A

Lighting: Enclosed and Gasketed — Area — Incandescent


A-21 60-150 3/4 VXHA1075G VXHA1075G-M VXHA1075G-A
1 VXHA1100G VXHA1100G-M VXHA10100G-A
1/2 VXHA2050G VXHA2050G-M VXHA2050G-A
PS-30 150-300 3/4 VXHA2075G VXHA2075G-M VXHA2075G-A
1 VXHA2100G VXHA2100G-M VXHA20100G-A

Wall — JB Box Mounting ② — Fits JB cast outlet box ③ — Screws and gasket furnished with fixture
JBW10G
A-21 60-150 JBW10G-M JBW10G-A

JBW20G
PS-30 150-300 JBW20G-M JBW20G-A

Ceiling – JB Box Mounting ② — Fits JB cast outlet box ③ — Screws and gasket furnished with fixture

A-21 60-150 JB10G JB10G-M JB10G-A


Lighting

PS-30 150-300 JB20G JB20G-M JB20G-A

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
③ JB cast outlet box is available in the Fitting Section.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1137


© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Catalog Numbers ①
Size Malleable Mounting Hood Aluminum Mounting Hood
Type Lamp Watts (Inches) with Aluminum Guard and Guard
Feed-Thru
1/2 VC1050G VC1050G-A
A21 60-150
3/4 VC1075G VC1075G-A
1/2 VC2050G VC2050G-A
PS30 150-300
3/4 VC2075G VC2075G-A

Ceiling – Three Hubs


1/2 VT1050G —
A21 60-150
3/4 VT1075G —
1/2 VT2050G —
PS30 150-300
Lighting: Enclosed and Gasketed — Area — Incandescent

3/4 VT2075G —

Outlet Box Mounting — For SEH cast outlet box ② or 3-1/4” or 4” octagonal outlet box ③ for non-classified areas only — Gasket
and adapter plate furnished with fixture

A21 60-150 OBV10G OBV10G-A

PS30 150-300 OBV20G OBV20G-A

Ceiling – Four Hubs


1/2 VX1050G —
A21 60-150
3/4 VX1075G —
1/2 VX2050G —
PS30 150-300
3/4 VX2075G —
Lighting

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② SEH cast outlet box is available in the Fitting Section.
③ Octagonal outlet box is available in the Commercial Fitting Section.
V CSA Certification only.

1138 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Catalog Numbers ①
Size Malleable Mounting Hood Aluminum Mounting Hood
Type Lamp Watts (Inches) with Aluminum Guard and Guard
Ceiling – Single Hub
1/2 V1050G V1050G-A
A21 60-150
3/4 V1075G V1075G-A
1/2 V2050G V2050G-A
PS30 150-300
3/4 V2075G V2075G-A

Wall – One Tapped Hub in Flange ②


1/2 VGA1050G —
A21 60-150
3/4 VGA1075G —

Lighting: Enclosed and Gasketed — Area — Incandescent


1/2 VGA2050G —
PS30 150-300
3/4 VGA2075G —

Wall – Vertical Feed-Thru ②


1/2 VD1050G —
A21 60-150
3/4 VD1075G —
1/2 VD2050G —
PS30 150-300
3/4 VD2075G —

Wall – Three Hubs Plus One Tapped Opening in Center of Flange ②


1/2 VGAT1050G —
A21 60-150
3/4 VGAT1075G VGAT1075G-A
Lighting

1/2 VGAT2050G —
PS30 150-300
3/4 VGAT2075G VGAT2075G-A

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1139


© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡

NEC: CSA: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Catalog Numbers ①
Malleable Mounting Hood Aluminum Mounting Hood
Type Lamp Watts with Aluminum Guard and Guard
45˚ Stanchion — Reflector not available for this fixture

A21 60-150 1-1/4 — VMAN10125G-A

PS30 150-300 1-1/4 — VMAN20125G-A

Wall – Outlet Box Mounting ② — Fits VPJB outlet box, SEH cast outlet box ③ or 3-1/4” or 4” octagonal outlet box ④ for non-
classified areas only — Gasket and adapter plate furnished with fixture

A21 60-150 OBVW10G OBVW10G-A

PS30 150-300 OBVW20G OBVW20G-A


Lighting: Enclosed and Gasketed — Area — Incandescent

Ceiling – GS Form 20 Box Mounting — Fits GS cast outlet box ③ — Screws and gasket furnished with fixture

A21 60-150 GS102G —

PS30 150-300 GS202G —

Wall – GS Box Mounting ② — Fits GSU cast outlet box ③ — Screws and gasket furnished with fixture

A21 60-150 GSW102G —

PS30 150-300 GSW202G —


Lighting

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
③ Cast outlet boxes are available in the Fitting Section.
④ Octagonal outlet boxes are available in the Commercial Fitting Section.
V CSA Certification only.

1140 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.

Catalog Numbers
Description Hub Size (Inches) Malleable Iron Aluminum
Pendant and Ceiling Mounting Hoods — Furnished with connection block, gasket and screws
Pendant Mounting
1/2 VA50 VA50-A
3/4 VA75 VA75-A
1 VA100 —
1-1/4 VA125 —
Dead-End ­— Ceiling Mounting
1/2 V50 V50-A
3/4 V75 V75-A
Feed-Thru — Ceiling Mounting
1/2 VC50 VC50-A
3/4 VC75 VC75-A
Three Hubs — Ceiling Mounting
1/2 VT50 —

Lighting: Enclosed and Gasketed — Area — Incandescent


3/4 VT75 —
Four Hubs — Ceiling Mounting
1/2 VX50 —
3/4 VX75 —
Five Hubs — Ceiling Mounting ①
1/2 VXHA50 VXHA50-A
3/4 VXHA75 VXHA75-A
1 VXHA100 VXHA100-A

Wall and Stanchion Mounting Hoods — Furnished with connection block, gasket and screws
One Opening — Wall Mounting ② — 1 tapped hole in center of flange
1/2 VGA50 —
3/4 VGA75 —

Feed-Thru — Wall Mounting ② — 2 tapped vertical feed-thru hubs


1/2 VD50 —
3/4 VD75 —

Three Hubs and One Opening – Wall Mounting ② — 3 hubs plus 1 tapped opening in
center of flange
1/2 VGAT50 —
Lighting

3/4 VGAT75 VGAT75-A

45° Stanchion Mounting


1-1/4 — VMAN-125

① Four close-up plugs furnished.


② Mounting hoods for wall installations can only be used with 30º angle reflectors.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1141


© September 2010
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.

Catalog Numbers
Wall Ceiling Type Malleable Iron Aluminum
Wall and Ceiling Outlet Box Mounting Hoods
SEH ① and 3-1/4” or 4” Octagonal Outlet Box Mounting ② for Non-Classified Areas Only
Wall ③ OBVW1 OBVW1-A
Ceiling OBV1 OBV1-A

GS Round Base Outlet Box Mounting – Form 20 ①


Wall ③ GSW2 —
Ceiling GS2 —

JB Round Base Outlet Box Mounting ①


Wall ③ JBW1 JBW1-A
Ceiling JB1 JB1-A
Lighting: Enclosed and Gasketed — Area — Incandescent

Catalog Numbers
A21 PS30 Type Lamp Watts Malleable Iron Aluminum
Fixture Units
Adapter/Socket, Globe and Guard
A21 60-150 VU100M VU-100
PS30 150-300 VU200M VU-200

Adapter/Socket and Globe


A21 60-150 VU100MLG VU-100LG
PS30 150-300 VU200MLG VU-200LG

Adapter/Socket
A21 60-150 VAD-1M ④ VAD-1
PS30 150-300 VAD-2M ④ VAD-2
Lighting

① Cast outlet boxes and gaskets are available in the Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood.
② Octagonal outlet boxes are available in the Commercial Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood.
③ Mounting hoods for wall installations can only be used with 30º angle reflectors.
④ Accepts steel wire guard only

1142 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.

Catalog Numbers
Type Lamp Watts Glass — 60-150 W Polycarbonate ­‑ 100 W Max. ①
Glass and Polycarbonate Globes — 60-150 W
Clear VGL-1CL VPG-1CL
Amber VGL-1AM VPG-1AM
Blue VGL-1BL VPG-1BL
Green VGL-1GR VPG-1GR
Opal VGL-1OP —
Red VGL-1RE VPG-1RE
60 W-150 W Glass 100 W Polycarbonate Clear Heat-Resistant VGL-1HR —

Glass Globes — 150-300W


Clear VGL-2CL —
Amber VGL-2AM —
Blue VGL-2BL —

Lighting: Enclosed and Gasketed — Area — Incandescent


Green VGL-2GR —
Opal VGL-2OP —
Red VGL-2RE —
Clear Heat-Resistant VGL-2HR —

Aluminum Guards ②
A21 ③ 60-150 VGU-1
PS30 ④ 150-300 VGU-2

VGU-2

Steel Wire Guards ②


A21 ⑤ 60-150 VWG-1
PS30 ⑥ 150-300 VWG-2
Lighting

VWG-1

① Do not use in ambients exceeding 77 ºF/25º C. For burning in base-up position only.
② Cannot be used with polycarbonate globes.
③ Fits VAD-1 Adapter)
④ Fits VAD-2 Adapter)
⑤ Fits VAD-1M Adapter)
⑥ Fits VAD-2M Adapter)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1143


© September 2010
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.

Description Type Lamp Watts Catalog Number


Porcelain Reflectors — Furnished with neoprene attaching ring
Standard Dome

A21 60-150 VRW-1ST

PS30 150-300 VRW-2ST

30˚ Angle

A21 60-150 VRW-1AN

PS30 150-300 VRW-2AN

Replacement Reflector Attaching Ring — Neoprene

VPT-8
Lighting: Enclosed and Gasketed — Area — Incandescent

Connection Block

VPT-7

Lamp Socket — Medium Base

VPT-1AV

Gasket for Lamp Socket and 60-150 W Globe

VPT-2

Gasket for 150-300 W Globe

VPT-3
Lighting

Gasket for Mounting Hood

VPT-4

1144 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
V-51® Incandescent Luminaire Dimensions
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.

Dimensions in Inches/Millimeters
3.50"/
12.7mm
3.81"/ 5.19"/
96.8 mm 131.8 mm 5.00"/
4.44"/ 127 mm
3.81"/ 112.8 mm
96.8mm
5.00"/
2.75"/ 127 mm 3.06"/
2.19"/ 77.7 mm
55.6 mm 69.9 mm

Type VA Types V, VC, VT and VX Type VXHA Types OBV and OBVW
3.50"/
88.9 mm
3.50"/ 3.50"/
2.38"/ 12.7mm 12.7mm
60.5 mm 2.63"/ 4.50"/
4.50"/ 66.8 mm 114.3 mm 4.00"/ 4.63"/
114.3 mm 101.6 mm

Lighting: Enclosed and Gasketed — Area — Incandescent


2.63"/ 4.00"/ 117.6 mm
101.6 mm 2.19"/
66.8 mm 55.6 mm
3.00"/ 4.00"/
76.2 mm 101.6 mm 4.63"/
117.6 mm

0.94"/ 0.75"/
23.9 mm 19.1 mm

Types VGA and VGAT Type VD Types JB and JBW Types GS and GSW

1/2 & 3/4 1 & 1-1/4


Size A B C D D
60-150 W 6.38/162.1 5.75/146.1 4.19/106.4 2.63/66.8 2.89/73.4
150-300 W 9.50/241.3 8.63/219.2 5.69/144.5 2.63/66.8 2.89/73.4

Reflectors

Lighting

Standard Dome 30˚ Angle


Standard Dome 30˚ Angle
Size A B A B
60-150 W 6.19/157.2 12.00/304.8 8.09/205.5 10.00/254.0
150-300 W 8.88/225.6 16.00/406.4 11.59/294.4 12.00/304.8

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1145


© September 2010
V-51® Incandescent Luminaire Photometric Data
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Full-size photometric data available for all V-51® fixtures on request.

Without Reflector Effective Floor Cavity Reflectance (Rfc) is 20%

% Ceiling Rcc 80 70 50 30 10 0

% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .815 .765 .721 .755 .711 .668 .642 .608 .577 .539 .513 .489 .444 .424 .406 .360
2 .690 .619 .558 .639 .575 .521 .542 .492 .449 .452 .414 .380 .370 .341 .315 .273

ROOM CAVITY RATIOS


3 .595 .515 .450 .551 .478 .421 .467 .410 .362 .388 .344 .307 .316 .282 .252 .215
4 .523 .439 .374 .485 .409 .350 .411 .351 .303 .343 .296 .257 .279 .242 .212 .178
5 .457 .376 .313 .426 .350 .292 .362 .300 .254 .302 .253 .215 .246 .208 .177 .147
6 .409 .326 .266 .378 .303 .248 .322 .261 .215 .269 .220 .183 .220 .180 .150 .123
7 .364 .283 .229 .338 .264 .213 .288 .226 .184 .240 .192 .155 .198 .158 .128 .104
8 .329 .251 .197 .305 .234 .185 .260 .202 .160 .220 .171 .136 .179 .141 .112 .090
9 .298 .223 .171 .277 .208 .161 .237 .180 .140 .199 .152 .119 .164 .126 .098 .078
10 .271 .198 .152 .251 .187 .142 .216 .161 .123 .182 .137 .104 .151 .113 .086 .068

Standard Dome Effective Floor Cavity Reflectance (Rfc) is 20%

% Ceiling Rcc 80 70 50 30 10 0
Lighting: Enclosed and Gasketed — Area — Incandescent

% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .803 .772 .744 .784 .756 .731 .750 .726 .706 .718 .701 .683 .691 .675 .661 .645
2 .705 .656 .614 .690 .645 .608 .661 .624 .591 .636 .605 .576 .612 .586 .562 .546
ROOM CAVITY RATIOS

3 .618 .558 .511 .606 .550 .506 .583 .535 .495 .560 .520 .486 .540 .506 .476 .460
4 .549 .484 .434 .538 .478 .430 .518 .465 .423 .499 .454 .417 .482 .442 .410 .393
5 .485 .416 .366 .475 .411 .363 .459 .401 .359 .442 .392 .354 .427 .384 .349 .333
6 .431 .362 .314 .423 .358 .310 .408 .350 .307 .394 .343 .304 .382 .335 .299 .284
7 .384 .316 .270 .377 .311 .267 .364 .304 .263 .351 .299 .260 .341 .294 .257 .242
8 .347 .281 .234 .340 .278 .233 .329 .272 .231 .319 .267 .229 .309 .262 .226 .212
9 .314 .249 .204 .309 .246 .204 .299 .242 .202 .289 .237 .200 .281 .233 .198 .184
10 .284 .221 .181 .279 .221 .181 .271 .216 .179 .263 .212 .176 .257 .209 .174 .161

30° Angle
Photometric data shown on this page is based on a 150 Watt PS-25 lamp
and is representative of the performance for all V-51 incandescent fixtures.
For candlepower values of fixtures with other lamps, multiply the given
candlepower values by the following multipliers: for 60 W – A19 X 0.33; for
75 W – A19 X 0.45; for 100 W – A19 X 0.66; for 200 W – PS25 X 1.44; and
for 300 W – PS30 X 2.32. For candlepower values of fixture with guard,
multiply by 0.90.
Lighting

1146 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
REA™ 150 W Incandescent Luminaires ①
Enclosed and Gasketed
UNILETS® for use with Threaded Metal Conduit. Medium Base. Inexpensive, Low Wattage Fixture for use in Wet Locations.

Applications
• Vaportight enclosed and gasketed lighting fixtures, suitable for
use in wet locations.
• Standard glass globes take up to 150 W A-21 lamps. Optional
polycarbonate plastic globes take up to 100 W A-21 lamps.
Features
• Inexpensive fixture designed for use without reflector.
• Spring-mounted shock-absorbing socket prolongs lamp life.
• Guards snap on easily and securely. Spring-action balls snap
into detents in fixture body.
Standard Materials
• Mounting bodies: pressure cast copperfree (4/10 of 1% max.)
aluminum
• Socket: porcelain with brass screw shell
• Guards: steel or aluminum guards
Standard Finishes
Pendant Outlet Box Wall
• Mounting bodies: burnished
• Steel wire guard: zinc electroplate
• Aluminum guard: aluminum polymer enamel
• Socket and globes: natural finish

Lighting: Enclosed and Gasketed — Area — Incandescent


Certifications and Compliances
• UL Standard: UL 1598

Dimensions in Inches/Millimeters

3.19"/
81.0 mm

3.50"/
12.7 mm
4.19"/
106.4 mm
11.81"/
300.0 mm

8.25"/
209.6 mm
6.38"/
162.1 mm Lighting

3.94"/ 3.75"/ 3.94"/


100.1 mm 96.3 mm
100.0 mm

Pendant Outlet Box Wall

① Maximum size A-21 lamp: glass globe – 150 Watts; plastic globe – 100 Watts. No reflectors are available for REA fixtures.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1147


© September 2010
REA™ 150 W Incandescent Luminaires ①
Enclosed and Gasketed
UNILETS® for use with Threaded Metal Conduit. Medium Base. Inexpensive, Low Wattage Fixture for use in Wet Locations.

Hub Size
Description (Inches) Catalog Number
Pendant Fixture
1/2 REA-1050
3/4 REA-1075

Outlet Box Fixture


Pendant Outlet Box
For 3-1/4” or 4” octagonal, or 4” square mounting. REA-10B

Wall Fixture
REA-10LB

Wall
Pendant Hood
1/2 REA-50
Lighting: Enclosed and Gasketed — Area — Incandescent

3/4 REA-75

Wall Bracket
1/2 male stem REA-1BR

Lamp Socket
VPLR-123

Steel Guard
For Outlet Box fixture only. VWG-1

Aluminum Guard
For Pendant and Wall Mount fixtures only. VGU-1
VWG-1 VGU-1

Catalog Number ①
Description Glass Plastic
Colored Glass and Polycarbonate Globes

Clear VGL-1CL VPG-1CL

Amber VGL-1AM VPG-1AM


Lighting

Blue VGL-1BL VPG-1BL

Green VGL-1GR VPG-1GR


Glass Plastic Opal VGL-1OP —

Red VGL-1RE VPG-1RE

Clear Heat-Resistant VGL-1HR —

① Maximum size A-21 lamp: glass globe – 150 Watts; plastic globe – 100 Watts. No reflectors are available for REA fixtures.

1148 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

NEC CEC V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Marine type electric fixtures, outside type Class II, Divisions I and 2, Groups E, F, G V
(salt water) Class III
Marine type electric fixtures, outside type
(salt water)

Applications
• Highly efficient, all-weather flood-lighting for lower wattage
service. Well suited for:
— Facades
— Amusement and recreational areas
— Parking lots
— Industrial and marine use
Features
• Ruggedly built for dependable, vandal resistant service.
Attractively styled. Easy to install, aim, add service, with easy
access to spacious interior.
.• Integral ballast.
• One-piece housing.
• One-piece lens cover. Secured by four 1/4” dia. captive
stainless steel slotted hex-head bolts.
• Thermal shock and impact resistant glass lens.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and spring-
loaded center contact. Yoke Mount
• Parabolic finished aluminum reflector for optimum efficiency.
• Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish
Standard Materials
• Ballast housing and lens cover: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell Pole Mount
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel

Lighting: Enclosed and Gasketed — Floodlight


Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10794
• CSA Certified: LR25428
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1149


© September 2010
Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS
For general, marine and hazardous locations.

NEC
Class I, Division 2, Groups A, B, C, D
Marine type electric fixtures, outside type
(salt water)

Catalog Number
Line Marine Yoke Mount ➊ for Yoke Mount ➊
Lamp Watts Lamp Type Voltages Class I, Division 2 Classified Duty for General Duty Slip-Fit Mount ➋

70 HPS 120/208/240/277 G-AM271L-MT-I/2 G-AM271L-MT G-AM275L-MT

70 HPS 480 G-AM271L-48-I/2 G-AM271L-48 G-AM275L-48

100 HPS 120/208/240/277 G-AM371L-MT-I/2 G-AM371L-MT G-AM375L-MT


Yoke Mount

100 HPS 480 G-AM371L-48-I/2 G-AM371L-48 G-AM375L-48

150 HPS 120/208/240/277 G-AM471L-MT-I/2 G-AM471L-MT G-AM475L-MT

150 HPS 480 G-AM471L-48-I/2 G-AM471L-48 G-AM475L-48


Pole Mount

Electrical Specifications T Numbers and Temperature Ratings of “Classified Duty”


Line Type of Starting Operating Total Lamp Ambient T Rating Temperature
T Rating
Voltage Ballast Amps Amps Watts Watts Temperature (°F/°C) Range (°F/°C)
70 Watt High Pressure Sodium 70 T3 104/40 358-392/181-200
120 HX-HPR 0.90 0.82 94 100 T2C 104/40 421-446/216-230
208 HX-HPR 0.50 0.48 94 150 T2 104/40 538-572/281-300
Lighting: Enclosed and Gasketed — Floodlight

240 HX-HPR 0.44 0.41 94


277 HX-HPR 0.35 0.36 94
480 HX-HPR 0.21 0.21 94
100 Watt High Pressure Sodium
120 HX-HPR 1.30 1.15 130
208 HX-HPR 0.76 0.67 130
240 HX-HPR 0.66 0.60 130
277 HX-HPR 0.60 0.52 130
480 HX-HPR 0.33 0.31 135
150 Watt High Pressure Sodium
120 HX-HPR 2.00 1.70 188
208 HX-HPR 1.16 0.95 188
240 HX-HPR 1.00 0.85 188
277 HX-HPR 0.85 0.72 188
480 HX-HPR 0.50 0.47 188

➊ Adjustable yoke mounts directly or with adapters.


Lighting

➋ Internally wired, adjustable slip-fit mount for 2” or 2-1/2” pipe.

1150 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 100 Wide-Beam Floodlights V
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

CEC V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions I and 2, Groups E, F, G V
Class III
Marine type electric fixtures, outside type
(salt water)

Catalog Number
Marine Yoke Mount ➊
Class I, Division 2,
Lamp Lamp Line Class II, Division 1 & 2 Yoke Mount ➊ Slip-Fit Mount ➋ Slip-Fit
Watts Type Voltages Class III for General Duty Class I, Division 2 Mount ➋
70 HPS 120/208/240/277 G-AM271L-MT-I/2CN G-AM271L-MTCN G-AM275L-MT-I/2CN G-AM275L-MTCN

70 HPS 120/277/347 G-AM271L-TT-I/2CN G-AM271L-TTCN G-AM275L-TT-I/2CN G-AM275L-TTCN

100 HPS 120/208/240/277 G-AM371L-MT-I/2CN G-AM371L-MTCN G-AM375L-MT-I/2CN G-AM375L-MTCN

100 HPS 120/277/347 G-AM371L-TT-I/2CN G-AM371L-TTCN G-AM375L-TT-I/2CN G-AM375L-TTCN

150 HPS 120/208/240/277 G-AM471L-MT-I/2CN G-AM471L-MTCN G-AM475L-MT-I/2CN G-AM475L-MTCN

Yoke Mount 150 HPS 120/277/347 G-AM471L-TT-I/2CN G-AM471L-TTCN G-AM475L-TT-I/2CN G-AM475L-TTCN

70 PSMH 120/208/240/277 G-AM271H-MT-I/2CN G-AM271H-MTCN G-AM275H-MT-I/2CN G-AM275H-MTCN

70 PSMH 120/277/347 G-AM271H-TT-I/2CN G-AM271H-TTCN G-AM275H-TT-I/2CN G-AM275H-TTCN

100 PSMH 120/208/240/277 G-AM371H-MT-I/2CN G-AM371H-MTCN G-AM375H-MT-I/2CN G-AM375H-MTCN

100 PSMH 120/277/347 G-AM371H-TT-I/2CN G-AM371H-TTCN G-AM375H-TT-I/2CN G-AM375H-TTCN

150 PSMH 120/208/240/277 G-AM471H-MT-I/2CN G-AM471H-MTCN G-AM475H-MT-I/2CN G-AM475H-MTCN


Slip-Fit 150 PSMH 120/277/347 G-AM471H-TT-I/2CN G-AM471H-TTCN G-AM475H-TT-I/2CN G-AM475H-TTCN

Electrical Specifications
Line Type of Starting Operating Total Line Type of Starting Operating Total
Voltage Ballast Amps Amps Watts Voltage Ballast Amps Amps Watts
70 Watt High Pressure Sodium 70 Watt Pulse Start Metal Halide
120 HX-HPR 0.90 0.82 94 120 HX-HPF 0.80 0.85 95
208 HX-HPR 0.50 0.48 94 208 HX-HPF 0.50 0.52 95
240 HX-HPR 0.44 0.41 94 240 HX-HPF 0.43 0.44 95
277 HX-HPR 0.35 0.36 94 277 HX-HPF 0.39 0.39 95
347 HX-HPF 0.30 0.30 94 347 HX-HPF 0.20 0.28 88
480 HX-HPR 0.21 0.21 94 480 HX-HPF 0.26 0.23 95

Lighting: Enclosed and Gasketed — Floodlight


100 Watt High Pressure Sodium 100 Watt Pulse Start Metal Halide
120 HX-HPR 1.30 1.15 130 120 HX-HPF 1.20 1.15 130
208 HX-HPR 0.76 0.67 130 208 HX-HPF 0.70 0.70 130
240 HX-HPR 0.66 0.60 130 240 HX-HPF 0.61 0.58 130
277 HX-HPR 0.60 0.52 130 277 HX-HPF 0.55 0.50 130
347 HX-HPF 0.45 0.39 130 347 HX-HPF 0.40 0.40 129
480 HX-HPR 0.33 0.31 135 480 HX-HPF 0.30 0.35 140
150 Watt High Pressure Sodium 150 Watt Pulse Start Metal Halide
120 HX-HPR 2.00 1.70 188 120 HX-HPF 1.75 1.60 188
208 HX-HPR 1.16 0.95 188 208 HX-HPF 1.30 1.00 188
240 HX-HPR 1.00 0.85 188 240 HX-HPF 0.85 0.80 188
277 HX-HPR 0.85 0.72 188 277 HX-HPF 0.77 0.70 188
347 HX-HPF 0.52 0.56 188 347 Super C.W.A. 0.65 0.55 185
480 HX-HPR 0.50 0.47 188 480 Super C.W.A. 0.45 0.42 185
T Numbers and Temperature Ratings of “Classified Duty”
Lamp Watts T Rating Ambient Temperature (°F/°C) T Rating Temperature Range (°F/°C)
70 T3 104/40 358-392/181-200
100 T2C 104/40 421-446/216-230
150 T2 104/40 538-572/281-300

➊ Adjustable yoke mounts directly or with adapters.


➋ Internally wired, adjustable slip-fit mount for 2” or 2-1/2” pipe.
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1151


© September 2010
Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

Mounting Fittings and Accessories


Description Catalog Number
Crossarm Mounting Bracket — Has 180° horizontal adjustment—degree-marked.
Facilitates mounting floodlight to crossarm or other flat surface, or to G-AM-8-WB.
Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed, G-AM-8-CA
architectural bronze POLYESTER finish.
Pipe or Wall Mount Bracket — Used with G-AM-8-CA. Clamps to 1” to 2-1/2”
pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt and crossarm G-AM-8-WB
bracket bolts. Malleable iron, zinc plated, chromate sealed, with architectural bronze
polyester finish.
Poletop Slip-Fitter — 1-1/2” or 2” pipe size poletop tenons. Includes floodlight
yoke bolt, 3 locking bolts, and cord grip. Body is malleable iron—zinc plated, G-SF20
chromate sealed, with cast aluminum cap. Assembly has architectural bronze
polyester finish.

Locking-Type Photocontrol Receptacle — For NEMA type photocontrol, with


installation hardware and instructions. Should not be mounted on Class I Division 2 G-1PCR
units.

Vandal Shield — UV stabilized polycarbonate, with installation hardware and


G-AM-2-VS
instructions.

Wire Guard — Mounts to lens door with screws furnished. Zinc plated. G-AM-2-G

Top Visor — Easy to install with hardware supplied. Aluminum, with architectural
G-AM-2-V
bronze polyester finish.
Lighting: Enclosed and Gasketed — Floodlight
Lighting

1152 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 100 Wide-Beam Floodlight Dimensions
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

Yoke Mount Pole Mount

Lighting: Enclosed and Gasketed — Floodlight


Crossarm Mounting Bracket Pipe or Wall Mount Bracket Poletop Slip-Fitter

Wire Guard Top Visor


Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1153


© September 2010
Areamaster™ 100 Wide-Beam Floodlight Photometric Data
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

Catalog Number Lamp Photometric Data


Watts 150 Horizontal Spread 141°
Lumens 16,000 Vertical Spread 115°
Bulb E-23-1/2 Clear Beam Lumens 8148
G-AM471L-MT Light Center Lgth. 5” Beam Efficiency 50.9%
Base Mogul Screw Max. CP. 5155
Total Lumens 8552
Total Efficiency 53.5%
Watts 100 Horizontal Spread 141°
Lumens 9500 Vertical Spread 115°
Bulb E-23-1/2 Clear Beam Lumens 4838
G-AM371L-MT Light Center Lgth. 5” Beam Efficiency 50.9%
Base Mogul Screw Max. CP. 3061
Total Lumens 5062
Total Efficiency 53.3%
Watts 70 Horizontal Spread 141°
Lumens 5800 Vertical Spread 113°
Bulb E-23-1/2 Clear Beam Lumens 2982
G-AM271L-MT Light Center Lgth. 5” Beam Efficiency 51.4%
Base Mogul Screw Max. CP. 2025
Total Lumens 3124
Total Efficiency 53.9%

Total Footcandle Value ‡ Footcandles for Iso-FTC Lines


150 Watt High Pressure Sodium - Clear 16,000 Lumens Ratio of Distance to Height
Lamp Mounting
Watts Height (Ft/M) 0.63 A 1.00 B 1.50 C 2.00 D 2.50 E 3.00 F 3.75 G
10/3.0 31.25 18.23 8.06 3.41 1.63 0.86 0.38
150 20/6.1 7.81 4.56 2.02 0.85 0.41 0.22 0.10
30/9.1 3.47 2.03 0.90 0.38 0.18 0.10 0.04
Lighting: Enclosed and Gasketed — Floodlight

10/3.0 18.44 10.76 4.76 2.01 0.96 0.51 0.22


100 20/6.1 4.61 2.69 1.19 0.50 0.24 0.13 0.06
30/9.1 2.05 1.20 0.53 0.22 0.11 0.06 0.02
10/3.0 11.25 6.56 2.90 1.23 0.59 0.31 0.14
70 20/6.1 2.81 1.64 0.73 0.31 0.15 0.08 0.04
30/9.1 1.25 0.73 0.32 0.14 0.06 0.04 0.01

‡ Photometric charts available upon request.


Lighting

* (i.e. ratio of distance to height. Example: @ 15'/4.6 m mounting height, 1 means 15'/4.6 m, 2 means 30'/9.1 m, etc.)

1154 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
NEC: For general, marine and hazardous CEC V: For general, marine and hazardous NEC/CEC:
locations locations IP66
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D Marine type electric fixtures, outside type
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC (salt water)
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• Powerful, efficient weatherproof lighting for medium and large
areas such as:
— Shopping malls
— Parking lots
— Sports areas
— New-car lot lighting
— Security lighting
— Industrial process lighting
Features
• Compact in size, attractively styled contemporary design,
rugged and dependable.
• Easy to install and service.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• One-piece housing.
• One-piece lens cover. Secured by four 1/4” Dia. captive
stainless steel slotted hex-head bolts.
• Thermal shock and impact resistant glass lens.
• Heavy duty, high temperature silicone rubber gasket, firmly Projected Area: 1.9 Sq. Ft.
seated.
• Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and spring-
loaded center contact. Dimensions in Inches/Millimeters
• Compound parabolic, double segment, finished aluminum
reflector for optimum efficiency.
• Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish
• Cool operating temperatures translate into long luminaire life.
Standard Materials
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum

Lighting: Enclosed and Gasketed — Floodlight


• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel
Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
Certifications and Compliances
• Areamaster 250/400
— UL Standard: UL 1598, UL 1598A, UL 844
— UL Listed: E10794
• Zone 2 Areamaster 250/400
— UL Standard: UL 1598, UL 1598A, UL 60079-0,
UL 60079-15
— UL Listed: E10794
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1155


© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
NEC: For general, marine and hazardous CEC V: For general, marine and hazardous NEC/CEC:
locations locations IP66
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D Marine type electric fixtures, outside type
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC (salt water)
Class II, Division 1 and 2, Groups E, F, G
Class III

“T” Numbers

Lamp NEC/CEC CEC V


Supply Wire Temp. Ambient Temp. Class I, Division 2, Class II, Division 1 NEC/CEC
Watts Type (°F/°C) (°F/°C) Groups A, B, C, D and 2, Groups E, F, G Class I, Zone 2
140/60 104/40 T3C T3B T6
70 HPS 167/75 131/55 T3B — T5
194/90 149/65 T3A — T4
167/75 104/40 T3 T3B T5
100 HPS 194/90 131/55 T2D — T4
221/105 149/65 T2C — T4
185/85 104/40 T2C T3B T4
150 HPS 221/105 131/55 T2B — T4
230/110 149/65 T2B — T3
167/75 104/40 350 T3B T4
250 HPS 194/90 131/55 350 — T3
221/105 149/65 T1 — T3
221/105 104/40 T1 T3B T3
400 HPS
257/125 122/50 — — T3
194/90 104/40 T2 T3B T4
175 PSMH 221/105 131/55 325 — T3
230/110 149/65 325 — T3
167/75 104/40 325 T3B T3
200 PSMH 185/85 131/55 325 — T3
221/105 149/65 325 — T3
185/85 104/40 325 T3B T3
250 PSMH 221/105 131/55 325 — T3
230/110 149/65 — — T3
185/85 104/40 325 T3B T3
320 PSMH
221/105 131/55 325 — T3
221/105 104/40 325 T3B T3
400 PSMH
239/115 131/55 325 — T3
Lighting: Enclosed and Gasketed — Floodlight

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR or AEx nR rating
“T” Number T1 T2 T3 T4 T5 T6

Temp. Range (°F) 547-842 394-572 277-392 214-275 187-212 185

Temp. Range (°C) 301-450 201-300 136-200 101-135 86-100 85


Lighting

V CSA Certification only.

1156 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH

NEC: For general, marine and hazardous Marine type electric fixtures, outside type
locations (salt water)
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC
IP66

For Class 1, Division 2 For General Duty


Classified Duty and Class I, Zone 2
Line Marine Yoke Mount Yoke Mount Slip-Fit Mount Yoke Mounting
Lamp Voltage Catalog Number ➋➌ Catalog Number ➋ Catalog Number ➊➋ Catalog Number ➌
High Pressure Sodium
120/208/240/277 G-AML271L-MT-I/2 — — G-AML271L-MT-Z2
70 W HPS ➍ 220 V 50 Hz G-AML271L-225-I/2 ➎ — — G-AML271L-225-Z2 ➎
480 G-AML271L-48-I/2 — — G-AML271L-48-Z2
120/208/240/277 G-AML371L-MT-I/2 — — G-AML371L-MT-Z2
100 W HPS ➍ 220 V 50 Hz G-AML371L-225-I/2 ➎ — — G-AML371L-225-Z2 ➎
480 G-AML371L-48-I/2 — — G-AML371L-48-Z2
120/208/240/277 G-AML471L-MT-I/2 — — G-AML471L-MT-Z2
150 W HPS ➍ 220 V 50 Hz G-AML471L-225-I/2 ➎ — — G-AML471L-225-Z2 ➎
480 G-AML471L-48-I/2 — — G-AML471L-48-Z2
120/208/240/277 G-AM671L-MT-I/2 G-AM671L-MT G-AM675L-MT G-AM671L-MT-Z2
250 W HPS 230 V 50 Hz G-AM671L-235-I/2 ➎ G-AM671L-235 ➎ G-AM675L-235 ➎ G-AM671L-235-Z2 ➏
480 G-AM671L-48-I/2 G-AM671L-48 G-AM675L-48 G-AM671L-48-Z2
120/208/240/277 G-AM771L-MT-I/2 G-AM771L-MT G-AM775L-MT G-AM771L-MT-Z2
400 W HPS 230 V 50 Hz G-AM771L-235-I/2 ➏ G-AM771L-235 ➏ G-AM775L-235 ➏ G-AM771L-235-Z2 ➏
480 G-AM771L-48-I/2 G-AM771L-48 G-AM775L-48 G-AM771L-48-Z2
Pulse Start Metal Halide
120/208/240/277 G-AM571P-MT-I/2 G-AM571P-MT G-AM575P-MT G-AM571P-MT-Z2
175 W PSMH
480 G-AM571P-48-I/2 G-AM571P-48 G-AM575P-48 G-AM571P-48-Z2
120/208/240/277 G-AM2071P-MT-I/2 G-AM2071P-MT G-AM2075P-MT G-AM2071P-MT-Z2
200 W PSMH
480 G-AM2071P-48-I/2 G-AM2071P-48 G-AM2075P-48 G-AM2071P-48-Z2
120/208/240/277 G-AM671P-MT-I/2 G-AM671P-MT G-AM675P-MT G-AM671P-MT-Z2

Lighting: Enclosed and Gasketed — Floodlight


250 W PSMH 230 V 50 Hz G-AM671P-235-I/2 ➏ G-AM671P-235 ➏ G-AM675P-235 ➏ G-AM671P-235-Z2 ➏
480 G-AM671P-48-I/2 G-AM671P-48 G-AM675P-48 G-AM671P-48-Z2
120/208/240/277 G-AM3271P-MT-I/2 G-AM3271P-MT G-AM3275P-MT G-AM3271P-MT-Z2
320 W PSMH 230 V 50 Hz G-AM3271P-235-I/2 ➏ G-AM3271P-235 ➏ G-AM3275P-235 ➏ G-AM3271P-235-Z2 ➏
480 G-AM3271P-48-I/2 G-AM3271P-48 G-AM3275P-48 G-AM3271P-48-Z2
120/208/240/277 G-AM771P-MT-I/2 G-AM771P-MT G-AM775P-MT G-AM771P-MT-Z2
400 W PSMH 230 V 50 Hz G-AM771P-235-I/2 ➏ G-AM771P-235 ➏ G-AM775P-235 ➏ G-AM771P-235-Z2 ➏
480 G-AM771P-48-I/2 G-AM771P-48 G-AM775P-48 G-AM771P-48-Z2

➊ Slip-fits 2” or 2-1/2” pipe-size tenons.


➋ Add suffix -E to catalog number if provision for quartz emergency option is desired. Furnished with socket installed and pre-wired.
➌ Quartz emergency option NOT available for Class I, Division 2 or Class I, Zone 2 fixtures. Classified duty floodlights have 1/2” N.P.T tapped hub for power entry.
Use 221 °F/105 °C supply wire.
➍ For Hot Restrike Option, add suffix –R.
➎ For 120 V 50 Hz change -225 to -125, or for 240 V 50 Hz change -225 to -245.
Lighting

➏ For 120 V 50 Hz change -235 to -125.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1157


© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights V
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH;
175 W, 250 W, 400 W MH
CEC V: For general, marine and hazardous IP66
locations Marine type electric fixtures, outside type
Class I, Division 2, Groups A, B, C, D (salt water)
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III

For Class 1, Division 2 For General Duty


Classified Duty and Class I, Zone 2
Line Marine Yoke Mount Yoke Mount Slip-Fit Mount Yoke Mounting
Lamp Voltage Catalog Number ➋➌ Catalog Number ➋ Catalog Number ➊➋ Catalog Number ➌
High Pressure Sodium
120/277/347 G-AML271L-TT-I/2 — — G-AML271L-TT-Z2
70 W HPS ➍ 220 V 50 Hz G-AML271L-225-I/2 ➎ — — G-AML271L-225-Z2 ➎
600 ➐ G-AML271L-C7-I/2 — — G-AML271L-C7-Z2
120/277/347 G-AML371L-TT-I/2 — — G-AML371L-TT-Z2
100 W HPS ➍ 220 V 50 Hz G-AML371L-225-I/2 ➎ — — G-AML371L-225-Z2 ➎
600 ➐ G-AML371L-C7-I/2 — — G-AML371L-C7-Z2
120/277/347 G-AML471L-TT-I/2 — — G-AML471L-TT-Z2
150 W HPS ➍ 220 V 50 Hz G-AML471L-225-I/2 ➎ — — G-AML471L-225-Z2 ➎
600 ➐ G-AML471L-C7-I/2 — — G-AML471L-C7-Z2
120/277/347 G-AM671L-TT-I/2 G-AM671L-TT G-AM675L-TT G-AM671L-TT-Z2
250 W HPS 230 V 50 Hz G-AM671L-235-I/2 ➎ G-AM671L-235 ➎ G-AM675L-235 ➎ G-AM671L-235-Z2 ➏
600 ➐ G-AM671L-C7-I/2 G-AM671L-C7 G-AM675L-C7 G-AM671L-C7-Z2
120/277/347 G-AM771L-TT-I/2 G-AM771L-TT G-AM775L-TT G-AM771L-TT-Z2
400 W HPS 230 V 50 Hz G-AM771L-235-I/2 ➏ G-AM771L-235 ➏ G-AM775L-235 ➏ G-AM771L-235-Z2 ➏
600 ➐ G-AM771L-C7-I/2 G-AM771L-C7 G-AM775L-C7 G-AM771L-C7-Z2
Pulse Start Metal Halide
175 W PSMH 120/277/347 G-AM571P-TT-I/2 G-AM571P-TT G-AM575P-TT G-AM571P-TT-Z2
200 W PSMH 120/277/347 G-AM2071P-TT-I/2 G-AM2071P-TT G-AM2075P-TT G-AM2071P-TT-Z2
120/277/347 G-AM671P-TT-I/2 G-AM671P-TT G-AM675P-TT G-AM671P-TT-Z2
250 W PSMH
230 V 50 Hz G-AM671P-235-I/2 ➏ G-AM671P-235 ➏ G-AM675P-235 ➏ G-AM671P-235-Z2 ➏
120/277/347 G-AM3271P-TT-I/2 G-AM3271P-TT G-AM3275P-TT G-AM3271P-TT-Z2
320 W PSMH
230 V 50 Hz G-AM3271P-235-I/2 ➏ G-AM3271P-235 ➏ G-AM3275P-235 ➏ G-AM3271P-235-Z2 ➏
120/277/347 G-AM771P-TT-I/2 G-AM771P-TT G-AM775P-TT G-AM771P-TT-Z2
400 W PSMH
230 V 50 Hz G-AM771P-235-I/2 ➏ G-AM771P-235 ➏ G-AM775P-235 ➏ G-AM771P-235-Z2 ➏
Lighting: Enclosed and Gasketed — Floodlight

Metal Halide
120/277/347 G-AM571H-TT-I/2 G-AM571H-TT G-AM575H-TT G-AM571H-TT-Z2
175 W MH 220 V 50 Hz G-AM571H-225-I/2 ➎ G-AM571H-225 ➎ G-AM575H-225 ➎ G-AM571H-225-Z2 ➎
600 ➐ G-AM571H-C7-I/2 G-AM571H-C7 G-AM575H-C7 G-AM571H-C7-Z2
120/277/347 G-AM671H-TT-I/2 G-AM671H-TT G-AM675H-TT G-AM671H-TT-Z2
250 W MH 220 V 50 Hz G-AM671H-225-I/2 ➎ G-AM671H-225 ➎ G-AM675H-225 ➎ G-AM671H-225-Z2 ➎
600 ➐ G-AM671H-C7-I/2 G-AM671H-C7 G-AM675H-C7 G-AM671H-C7-Z2
120/277/347 G-AM771H-TT-I/2 G-AM771H-TT G-AM775H-TT G-AM771H-TT-Z2
400 W MH 220 V 50 Hz G-AM771H-225-I/2 ➎ G-AM771H-225 ➎ G-AM775H-225 ➎ G-AM771H-225-Z2 ➎
600 ➐ G-AM771H-C7-I/2 G-AM771H-C7 G-AM775H-C7 G-AM771H-C7-Z2

➊ Slip-fits 2” or 2-1/2” pipe-size tenons.


➋ Add suffix -E to catalog number if provision for quartz emergency option is desired. Furnished with socket installed and pre-wired.
➌ Quartz emergency option NOT available for Class I, Division 2 or Class I, Zone 2 fixtures. Classified duty floodlights have 1/2” N.P.T tapped hub for power entry.
Use 221 °F/105 °C supply wire.
➍ For Hot Restrike Option, add suffix –R.
➎ For 120 V 50 Hz change -225 to -125, or for 240 V 50 Hz change -225 to -245.
➏ For 120 V 50 Hz change -235 to -125.
➐ Supplied complete with CWI Isolated Secondary Ballast for 600 Vac. For 208, 240 or 480 V applications, change the -C7 suffix to -C2, -C3 or -C6 as required.
Lighting

V CSA Certification only.

1158 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V

Dimensions Description Catalog Numbers


Crossarm Mounting Bracket

Has 180° horizontal adjustment — degree marked. Facilitates mounting


floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
G-AM-8-CA
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.

Pipe or Wall Mount Bracket

Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,


or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
G-AM-8-WB
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.

Poletop Slip-Fitter

Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
G-SF20
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.

Locking-Type Photocontrol Receptacle

For NEMA type photocontrol, with installation hardware and instructions.


G-1PCR
Should not be mounted on Class I, Division 2/Class 1, Zone 2 units.

Vandal Shield

Lighting: Enclosed and Gasketed — Floodlight


UV stabilized polycarbonate, with installation hardware and instructions. G-AM-6-VS

Top Visor

Easy to install with hardware supplied. Aluminum, with architectural bronze


G-AM-6-V
POLYESTER finish.

Replacement Lens

604249003

Replacement Lens Frame Assembly


Complete with Lens 59607383002
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1159


© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
NEC: For general, marine and hazardous CEC V: For general, marine and hazardous NEC/CEC:
locations locations IP66
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D Marine type electric fixtures, outside type
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC (salt water)
Class II, Division 1 and 2, Groups E, F, G
Class III

Line Type of Starting Operating Total Line Type of Starting Operating Total
Frequency Frequency
Voltage Ballast Amps Amps Watts Voltage Ballast Amps Amps Watts
70 Watt High Pressure Sodium 250 Watt Pulse Start Metal Halide
120 60 HX-HPF 0.90 0.82 94 120 60 Super CWA 1.90 2.50 288
208 60 HX-HPF 0.50 0.48 94 208 60 Super CWA 1.10 1.45 288
240 60 HX-HPF 0.44 0.41 94 240 60 Super CWA 0.96 1.25 288
277 60 HX-HPF 0.35 0.36 94 277 60 Super CWA 0.85 1.10 288
347V 60 HX-HPF 0.30 0.30 93 347V 60 Super CWA 0.62 0.90 291
480 60 HX-HPF 0.21 0.21 94 480 60 Super CWA 0.45 0.60 285
120 50 HX-HPF 1.08 0.81 97 120 50 Super CWA 1.90 2.60 285
220 50 HX-HPF 0.59 0.49 97 230 50 Super CWA 1.00 1.35 285
240 50 HX-HPF 0.54 0.45 97 320 Watt Pulse Start Metal Halide
100 Watt High Pressure Sodium 120 60 Super CWA 2.60 3.25 368
120 60 HX-HPF 1.30 1.15 130 208 60 Super CWA 1.50 1.90 368
208 60 HX-HPF 0.76 0.67 130 240 60 Super CWA 1.30 1.65 368
240 60 HX-HPF 0.66 0.60 130 277 60 Super CWA 1.15 1.40 368
277 60 HX-HPF 0.60 0.52 130 347V 60 Super CWA 0.70 1.10 368
347V 60 HX-HPF 0.45 0.39 130 480 60 Super CWA 0.60 0.80 368
480 60 HX-HPF 0.33 0.31 135 120 50 Super CWA 2.28 3.05 365
120 50 HX-HPF 0.90 1.20 130 230 50 Super CWA 1.14 1.60 365
220 50 HX-HPF 0.50 0.65 130 400 Watt Pulse Start Metal Halide
240 50 HX-HPF 0.45 0.60 130 120 60 Super CWA 3.50 4.00 454
150 Watt High Pressure Sodium 208 60 Super CWA 2.00 2.30 454
120 60 HX-HPF 2.00 1.70 188 240 60 Super CWA 1.25 2.00 454
208 60 HX-HPF 1.15 0.95 188 277 60 Super CWA 1.50 1.75 454
240 60 HX-HPF 1.00 0.85 188 347V 60 Super CWA 1.10 1.35 452
277 60 HX-HPF 0.85 0.72 188 480 60 Super CWA 0.90 1.00 454
347V 60 HX-HPF 0.52 0.56 188 120 50 Super CWA 3.17 3.90 454
480 60 HX-HPF 0.50 0.47 189 230 50 Super CWA 1.65 2.00 454
120 50 HX-HPF 1.50 1.60 188 175 Watt Metal Halide V
220 50 HX-HPF 0.85 0.90 188 120 60 CWA 1.30 1.80 213
240 50 HX-HPF 0.75 0.80 188 208 60 CWA 0.75 1.10 213
250 Watt High Pressure Sodium 240 60 CWA 0.65 0.90 213
120 60 CWA 2.00 2.50 295 277 60 CWA 0.55 0.80 213
208 60 CWA 1.20 1.50 295 347 60 CWA 0.50 0.65 210
240 60 CWA 1.00 1.30 295 480 60 CWA 0.35 0.45 213
277 60 CWA 0.85 1.10 295 120 50 CWA 1.70 1.90 210
347V 60 CWA 0.60 0.93 295 220 50 CWA 0.80 1.10 210
480 60 CWA 0.40 0.65 295 250 Watt Metal Halide V
120 50 CWA 1.85 2.75 300 120 60 CWA 1.20 2.60 295
Lighting: Enclosed and Gasketed — Floodlight

230 50 CWA 0.95 1.44 300 208 60 CWA 0.65 1.50 295
400 Watt High Pressure Sodium 240 60 CWA 0.60 1.30 295
120 60 CWA 3.30 3.80 465 277 60 CWA 0.50 1.12 295
208 60 CWA 1.80 2.20 465 347 60 CWA 0.80 0.90 295
240 60 CWA 1.60 1.90 465 480 60 CWA 0.30 0.65 298
277 60 CWA 1.40 1.70 465 120 50 CWA 2.00 2.50 285
347V 60 CWA 1.00 1.32 464 220 50 CWA 0.94 1.30 285
480 60 CWA 0.80 1.00 465 400 Watt Metal Halide V
120 50 CWA 3.70 4.00 465 120 60 CWA 3.25 4.00 458
230 50 CWA 1.85 2.00 465 208 60 CWA 1.90 2.30 458
175 Watt Pulse Start Metal Halide 240 60 CWA 1.65 2.00 458
120 60 Super CWA 0.90 1.78 199 277 60 CWA 1.40 1.75 458
208 60 Super CWA 0.50 1.08 199 347 60 CWA 1.20 1.40 460
240 60 Super CWA 0.35 0.89 199 480 60 CWA 0.85 1.00 462
277 60 Super CWA 0.30 0.76 199 120 50 CWA 2.70 4.10 480
347V 60 Super CWA 0.25 0.65 208 220 50 CWA 1.50 2.20 480
480 60 Super CWA 0.25 0.50 213
200 Watt Pulse Start Metal Halide
120 60 Super CWA 2.10 2.00 235
208 60 Super CWA 1.15 1.25 235
240 60 Super CWA 1.10 1.00 235
277 60 Super CWA 0.75 0.85 235
347V 60 Super CWA 0.25 0.70 232
480 60 Super CWA 0.35 0.50 237
Lighting

V CSA Certification only.

1160 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V

Typical Footcandle Values  Ft. Cdles for Iso-Footcandle Lines


Mtg. Ht. A B C D E F
400W HPS
60’/18.3m 3.27 2.74 1.82 0.92 0.37 0.18
50’/15.2m 4.74 4.00 2.90 1.37 0.52 0.27
40’/12.2m 7.65 6.28 4.38 2.27 0.82 0.43
30’/9.1m 13.10 10.92 7.83 3.47 1.45 0.77
20’/6.1m 28.22 25.55 17.37 7.28 3.46 1.82
400W MH V
60’/18.3m 2.32 1.66 1.00 0.58 0.33 0.17
Distance in terms of mounting height ◊

50’/15.2m 3.32 2.32 1.49 0.76 0.48 0.25


40’/12.2m 5.48 3.62 2.32 1.33 0.75 0.36
30’/9.1m 9.79 7.80 3.98 2.16 1.33 0.68
20’/6.1m 17.26 14.60 9.30 5.31 3.15 1.49
For 400W PSMH multiply FC values by 1.29; for 320W PSMH use 0.97.
400W PSMH
60’/18.3m 2.60 1.86 1.12 0.65 0.37 0.19
50’/15.2m 3.72 2.60 1.66 0.85 0.54 0.28
40’/12.2m 6.14 4.05 2.60 1.49 0.84 0.40
30’/9.1m 10.96 8.74 4.46 2.42 1.49 0.76
20’/6.1m 19.33 16.35 10.41 5.94 3.53 1.67
Ft. Cdles for Iso-Footcandle Lines
Mtg. Ht. G H I J K L
70W HPS
10’/3.0m 10.00 5.00 2.50 1.00 0.50 0.25
Distance in terms of mounting height ◊ 20’/6.1m 2.50 1.00 0.50 0.25 0.10 0.05
30’/9.1m 1.00 0.50 0.25 0.10 0.05 0.02
For 100W HPS lamps, multiply FC values by 1.5. For 150W HPS lamps, multiply FC values by 2.5.
Ft. Cdles for Iso-Footcandle Lines
Mtg. Ht. A B C D E F
250W HPS
60’/18.3m 1.96 1.64 1.09 0.55 0.22 0.11
50’/15.2m 2.84 2.40 1.74 0.82 .031 0.16

Lighting: Enclosed and Gasketed — Floodlight


40’/12.2m 4.58 3.76 2.62 1.36 0.49 0.26
Distance in terms of mounting height ◊

30’/9.1m 7.85 6.54 4.69 2.08 0.87 0.46


20’/6.1m 16.90 15.30 10.40 4.36 2.07 1.09
250W MH V
60’/18.3m 1.40 1.00 0.60 0.35 0.20 0.10
50’/15.2m 2.00 1.40 0.90 0.46 0.29 0.15
40’/12.2m 3.30 2.18 1.40 0.80 0.45 0.22
30’/9.1m 5.90 4.70 2.40 1.30 0.80 0.41
20’/6.1m 10.40 8.80 5.60 3.20 1.90 0.90
For 175W MH lamps, multiply FC values by 0.68. For 175W PSMH Lamps 0.85; for 200W PSMH
use 1.03; for 250W PSMH use 1.22.
250W PSMH
60’/18.3m 1.90 1.63 0.82 0.48 0.27 0.14
50’/15.2m 2.72 1.90 1.22 0.63 0.39 0.20
40’/12.2m 4.48 2.96 1.90 1.09 0.61 0.30
Distance in terms of mounting height ◊
30’/9.1m 8.00 6.40 3.26 1.76 1.09 0.55
20’/6.1m 14.40 11.97 7.61 4.35 2.58 1.22
For 175W MH lamps, multiply FC values by 0.68. For 175W PSMH Lamps 0.85; for 200W PSMH
use 1.03; for 250W PSMH use 1.22.
 (i.e., ratio of distance to height. Example: @ 20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.
 Photometric charts available on request.
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1161


© September 2010
Areamaster™ 1000 Floodlights
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

NEC: For general, marine and hazardous CEC V: For general, marine and hazardous
locations locations
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC

Applications
• Powerful, efficient weatherproof floodlights for large areas
such as:
— Shopping malls
— Industrial complexes
— Ship loading areas
— Mining sites
— Parking lots
— Sports areas
• Suitable for wet locations.
Features
• Highly efficient, integrally ballasted floodlight. Has compact,
lightweight, yet rugged diecast aluminum construction.
Combines architecturally beautiful design with rugged
dependability, simple installation and maintenance.
• Easy to install and service.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast. Yoke Slip-Fit
• One-piece housing.
• One-piece lens cover. Secured by four 1/4” Dia. captive
stainless steel slotted hex-head bolts. Projected Area: 3.36 Sq. Ft.
• Thermal shock and impact resistant glass lens.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and spring-
loaded center contact.
• Compound parabolic, double segment, finished aluminum
reflector for optimum efficiency.
• Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish.
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish.
• Cool operating temperatures for Class I, Division 2 fixtures
translate into long luminaire life.
Lighting: Enclosed and Gasketed — Floodlight

Standard Materials
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel
Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E10794
Lighting

V CSA Certification only.

1162 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 1000 Floodlights
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

NEC: For general, marine and hazardous CEC V: For general, marine and hazardous
locations locations
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC

NEC/CEC General Duty CEC


Class 1, Division 2 Class I, Zone 2, Ex nR
Classified Duty and NEC/CEC NEC/CEC Classified Duty and
Lamp Line Marine Yoke Mount Yoke Mount Slip-Fit Mount Marine Yoke Mount
Watts ➍ Voltage ➍ Catalog Number ➌ Catalog Number ➋ Catalog Number ➊➋ Catalog Number ➌
High Pressure Sodium

1000 120/208/240/277 G-AM861L-MT-I/2 G-AM861L-MT G-AM865L-MT G-AM861L-MT-Z V

1000 120/277/347 G-AM861L-TT-I/2 V G-AM861L-TT V G-AM865L-TT V G-AM861L-TT-Z V

1000 480 G-AM861L-48-I/2 G-AM861L-48 G-AM865L-48 G-AM861L-48-Z V

Metal Halide

1000 120/208/240/277 G-AM861H-MT-I/2 G-AM861H-MT G-AM865H-MT G-AM861H-MT-Z V

1000 120/277/347 G-AM861H-TT-I/2 V G-AM861H-TT V G-AM865H-TT V G-AM861H-TT-Z V

1000 480 G-AM861H-48-I/2 G-AM861H-48 G-AM865H-48 G-AM861H-48-Z V

1500 120/208/240/277 — G-AM961H-MT G-AM965H-MT —

1500 480 — G-AM961H-48 G-AM965H-48 —

Dimensions

Lighting: Enclosed and Gasketed — Floodlight


Slip-Fit Mount

Yoke Mount

➊ Slip-fits 2” or 2-1/2” pipe-size tenons.


➋ Add suffix -E to catalog number if provision for bayonet type quartz emergency option is desired. Furnished with socket installed and pre-wired. Quartz
emergency option NOT available for Class I, Division 2 fixtures.
➌ Classified duty floodlights have 3/4” N.P.T. tapped hub for power entry.
➍ Additional ballast types and voltages are available. Contact your local sales representative.
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1163


© September 2010
Areamaster™ 1000 Floodlight Mounting Fittings and Accessories
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

Dimensions Description Catalog Numbers


Crossarm Mounting Bracket

Has 180° horizontal adjustment — degree marked. Facilitates mounting


floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
G-AM-8-CA
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.

Pipe or Wall Mount Bracket

Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,


or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
G-AM-8-WB
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.

Poletop Slip-Fitter

Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking


bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with G-AM-8-SF
architectural bronze POLYESTER finish.

Locking-Type Photocontrol Receptacle

For NEMA type photocontrol, with installation hardware and instructions.


G-1PCR
Should not be mounted on Class I, Division 2 units.

Vandal Shield
Lighting: Enclosed and Gasketed — Floodlight

UV stabilized polycarbonate, with installation hardware and instructions. G-AM-8-NVS

Top Visor

Easy to install with hardware supplied. Aluminum, with architectural bronze


G-AM-6-NV
POLYESTER finish.

Replacement Lens

59604249004

Replacement Lens Frame Assembly


Complete with Lens 59617539001
Lighting

1164 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster™ 1000 Floodlight Photometric Data
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

Typical Footcandle Values † Photometric Data †


HPS MH
Horiz. Spread 134° 133°
Vert. Spread 131° 124°
Beam Lumens 77,440 62,112
Beam Effic. 55.3% 56.5%
Max. CP 40,251 45,909
Avg. Max. CP 38,396 38,490
Total Lumens 80,846 66,008
Total Effic. 57.7% 60.0%

Electrical Specifications
Lamp Line Type of Starting Operating Total
Type Voltage Ballast Amps Amps Watts
1000 Watt High Pressure Sodium
HPS 120 C.W.A. 6.35 9.50 1100
HPS 208 C.W.A. 3.80 5.50 1100
HPS 240 C.W.A. 3.20 4.80 1100
HPS 277 C.W.A. 2.75 4.20 1100
HPS 347 C.W.A. 2.20 3.30 1100
HPS 480 C.W.A. 1.80 2.45 1100
1000 Watt Metal Halide
MH 120 C.W.A. 8.00 9.20 1080
MH 208 C.W.A. 4.60 5.30 1080
MH 240 C.W.A. 4.00 4.60 1080
MH 277 C.W.A. 3.50 4.00 1080
MH 347 C.W.A. 2.50 3.20 1080
MH 480 C.W.A. 2.00 2.30 1080
1500 Watt Metal Halide
MH 120 C.W.A. 13.50 14.00 1610
MH 208 C.W.A. 7.70 8.00 1610
MH 240 C.W.A. 6.70 7.00 1610

Lighting: Enclosed and Gasketed — Floodlight


MH 277 C.W.A. 5.90 6.00 1610
MH 480 C.W.A. 3.30 3.50 1610

Mtg. Ht. Footcandle Values for Iso Footcandle Lines T Numbers and Temperature Ratings of “Classified Duty”
Ft/M A B C D E F Areamaster 1000
1000W HPS Clear, 140,000 Lumens, Cat. No. G-AM861L-MT
60/18.3 8.0 3.0 1.0 0.5 0.20 0.10 Fixture T Ratings Ambient T Rating Temperature
50/15.2 11.5 4.6 1.5 0.72 0.27 0.15 Wattage Fixture Type °C Temp. ˚°F/°C Range °F/°C
40/12.2 17.3 6.8 2.4 1.0 0.45 0.21 Class I
1000 325 77/25 574-617 / 301-325
30/9.1 31.5 12 4.1 1.9 0.80 0.30 Div 2
1000W MH Clear, 110,000 Lumens, Cat. No. G-AM861H-MT
1000 V Ex nR IIC T3 77/25 277-392 / 136-200
60/18.3 6.0 3 1.0 0.5 0.20 0.10
50/15.2 8.2 4.2 1.4 0.8 0.28 0.15
40/12.2 12.6 7.9 2.3 1.2 0.42 0.19
30/9.1 23.0 11.6 4.0 2.1 0.70 0.25

† Photometric charts available on request.


◊ i.e., ratio of distance to height. Example: @20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.
V CSA Certification only.
Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1165


© September 2010
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for si­mul­ta­ne­ous ex­po­sure to gas, com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Zone 2, 21 and 22
II 2 D - II 3 GD
ATEX / IECEx
IP66 - IK07/08

Applications
• Powerful, efficient floodlights for large areas such as industrial
complexes and ship loading areas.
• Rated for use in hazardous areas.
Features
• Highly efficient, integrally ballasted floodlight. Has compact,
lightweight, yet rugged die cast aluminum construction.
• Simple installation and maintenance.
• Integral ballast; 230/240 V, 50 Hz.
• One-piece lens cover.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Socket: E40 (E27 for 70 W HPS version).
• Reflectors: double segment compound parabolic with Alzack®
finish for maximum efficiency.
• Mounting: yoke mount.
Standard Materials
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum • Size G — Certification Type PJn
• Yoke mount: zinc plated steel — Gas: Zone 2
• Bolts: stainless steel  Conforming to ATEX 94/9/CE: CE 3G
 ATEX/IEC Protection: Ex nR II
Standard Finishes  T Rating: T3
• Ballast housing, lens cover, yoke and pole mount: architectural — Dust: Zone 22
bronze polyester  Conforming to ATEX 94/9/CE: CE II 3 D
• Socket: nickel-plated  ATEX/IEC Protection: Ex tD A22
Certifications and Compliances  Surface Temperature: T369 °F to T378 °F/T187 °C
to T192 °C
• Size M — Certification Type PJn — Gas, Zone 2 and Dust, Zone 22
— Gas: Zone 2  Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C
 Conforming to ATEX 94/9/CE: CE 3G  CE Declaration of Conformity: 50215
 ATEX/IEC Protection: Ex nR II  ATEX Certificate: LCIE 08 ATEX 6035X
 T Rating: T2 to T4  IEC Certificate: IECEx LCI 04.0015
 Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C  Other Certifications: GOST
Lighting: Enclosed and Gasketed — Floodlight

— Dust: Zone 22  Impact Resistance (shock): IK07


 Conforming to ATEX 94/9/CE: CE II 3 D — Dust: Zone 21
 ATEX/IEC Protection: Ex tD A22  Conforming to ATEX 94/9/CE: CE 008 II 2 D
 Surface Temperature: T243 °F/T117 °C to 442 °F/T228 °C  ATEX/IEC Protection: Ex tD A21
— Gas, Zone 2 and Dust, Zone 22  Surface Temperature: T250°F to T360°F / T121°C
 Ambient Temperature: 104 °F to 131 °F / 40 °C to 55 °C to T182°C
 ATEX Certificate: LCIE 08 ATEX 6035X  Ambient Temperature: -4°F to 104°F / -20°C to 40°C
 IEC Certificate: IECEx LCI 04.0015  CE Declaration of Conformity: 50274
 Other Certifications: GOST  ATEX Certificate: LCIE 02 ATEX 6246X
 Impact Resistance (shock): IK07  Impact Resistance (shock): IK07 with glass diffuser, IK08
— Dust: Zone 21 with polycarbonate diffuser
 Conforming to ATEX 94/9/CE: CE I2D — Index of Protection (solid and liquid): IP66
 ATEX/IEC Protection: Ex tD A21 • Ex Standards: EN/IEC 60079-0, 60079-15, 61241-0, 61241-1
 Surface Temperature: T149 °F to T277 °F/T65 °C to • Product Standards: EN/IEC 60598-1
T136 °C • EMC Standards: EN/IEC 55015, 61547
 Ambient Temperature: -4 °F to 104 °F/-20 °C to 40 °C • Other Standards: EN/IEC 60529 (IP)
 ATEX Certificate: LCIE 02 ATEX 6246X
 Impact Resistance (shock): IK07 with glass diffuser, IK08
with polycarbonate diffuser
— CE Declaration of Conformity: 50251
— Index of Protection (solid and liquid): IP66
Lighting

1166 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for si­mul­ta­ne­ous ex­po­sure to gas, com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Zone 2, 21 and 22
II 2 D - II 3 GD
ATEX / IECEx
IP66 - IK07/08

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For PN Series Luminaires
PN P 1 H 70 A G MT F

Series: Mounting: Wattage: Diffuser: Options:


PN - PN Series 1 - Yoke 70 - 70 W G - Glass S - Stainless Steel
Zone 2, 21 & 22 5 - Pole Slip-fit 15 - 150 W P - Polycarbonate ② Housing
ATEX / IEC Certified 25 - 250 W
40 - 400 W ①
99 - 1000 W ①

Body Size: Lamp Type: Entry Size: Options:


P - Small H - Metal Halide A - M20 XA - 220 Vac 50 Hz
M - Medium L - Sodium (Magnetic Ballast)
L - Large M - Mercury XJ - 230/240 Vac 50 Hz
(Magnetic Ballast)

Lighting: Enclosed and Gasketed — Floodlight

① 400 W Zones 21-22 and 1000 W Zones 2-22 only with large body (suffix -G).
Lighting

② Zone 2-22 doesn’t exist with polycarbonate diffuser.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1167


© September 2010
PN Series Floodlight T Ratings – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for si­mul­ta­ne­ous ex­po­sure to gas, com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Zone 2, 21 and 22
II 2 D - II 3 GD
ATEX / IECEx
IP66 - IK07/08

Zone 21 (Dust)
Dust Surface Temperatures for Ta = 104 °F/40 °C

Operating Position
Time Before Opening
Lamp and Power Glass Diffuser Polycarbonate Diffuser in Inches/Millimeters
70 W Sodium 167 °F/75 °C 149 °F/65 °C 1.97/50
150 W Sodium 213.8 °F/101 °C 195.8 °F/91 °C 0.99/25
Body Size: M 250 W Sodium 260.6 °F/127 °C 242.6 °F/117 °C 0.59/15
250 W Metal Halide 253.4 °F/123 °C 235.4 °F/113 °C 0.59/15
250 W Mercury 276.8 °F/136 °C 267.8 °F/131 °C 0.59/15
400 W Sodium 25.8 °F/126 °C 249.8 °F/121 °C 1.18/30
Body Size: L 1000 W Sodium 350.6 °F/177 °C – 1.18/30
1000 W Metal Halide 359.6 °F/182 °C – 1.18/30

Zone 2 (Gas)
Lamp and Power T Rating for Ta = 104 °F/40 °C T Rating for Ta = 122 °F/50 °C T Rating for Ta = 131 °F/55 °C
70 W Sodium T4 T4 T4
150 W Sodium T4 T4 T4
150 W Metal Halide T4 T4 T4
250 W Sodium T3 T3 T3 (Cable T ° = 179.6 °F/82 °C)
Body Size: M 250 W Metal Halide T3 T3 T3
250 W Mercury T3 T3 T3 (Cable T ° = 177.8 °F/81 °C)
400 W Sodium T3 T3 (Cable T ° = 188.6 °F/87 °C) T2 (Cable T ° = 197.6 °F/92 °C)
400 W Metal Halide T2 T2 (Cable T ° = 183.2 °F/84 °C) T2 (Cable T ° = 192.2 °F/89 °C)
400 W Mercury T2 T2 (Cable T ° = 183.2 °F/84 °C) T2 (Cable T ° = 192.2 °F/89 °C)
1000 W Sodium T3 T3 –
Body Size: L
1000 W Metal Halide T3 T3 –
Lighting: Enclosed and Gasketed — Floodlight

Zone 22 (Dust)
Lamp and Power T Rating for Ta = 104 °F/40 °C T Rating for Ta = 122 °F/50 °C T Rating for Ta = 131 °F/55 °C
70 W Sodium 242.6 °F/117 °C – –
150 W Sodium 2.66 °F/130 °C – –
150 W Lodure 262.4 °F/128 °C – –
250 W Sodium 320 °F/160 °C – T3 (Cable T ° = 179.6 °F/82 °C)
Body Size: M 250 W Lodure 47 °F/175 °C – –
250 W Mercury 357.8 °F/181 °C – T3 (Cable T ° = 177.8 °F/81 °C)
400 W Sodium 388.4 °F/198 °C T3 (Cable T ° = 188.6 °F/87 °C) T2 (Cable T ° = 197.6 °F/92 °C)
400 W Lodure 442.4 °F/228 °C T2 (Cable T ° = 183.2 °F/84 °C) T2 (Cable T ° = 192.2 °F/89 °C)
400 W Mercury 440.6 °F/227 °C T2 (Cable T ° = 183.2 °F/84 °C) T2 (Cable T ° = 192.2 °F/89 °C)
368.6 °F/187 °C
1000 W Sodium Cable T ° = 194 °F/90 °C –
(for Ta = 122 °F/50 °C)
Body Size: L
377.6 °F/192 °C
1000 W Lodure Cable T ° = 194 °F/90 °C –
(for Ta = 122 °F/50 °C)
Lighting

1168 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Zone 2, 21 and 22
II 2 D - II 3 GD
ATEX / IECEx
IP66 - IK07/08

Permissible lamps
Type Weight (lbs/kg) Volume (in3/dm3) (not supplied) Body Size Catalog Number
Standard with Lamp Glass Sealed on Frame
70 W HP Sodium 26.7/12.1 3814/62.5 Ovoid/Tubular Medium PNM1L70AGXJ
150 W HP Sodium 28.4/12.9 3814/62.5 Ovoid/Tubular Medium PNM1L15AGXJ
250 W HP Sodium 31.5/14.3 3814/62.5 Ovoid/Tubular Medium PNM1L25AGXJ
400 W HP Sodium 35.3/16.0 3814/62.5 Ovoid/Tubular Medium PNM1L40AGXJ
400 W HP Sodium – – Ovoid/Tubular Large PNL1L40AGXJ
150 W Metal Halide 28.4/12.9 3814/62.5 Ovoid/Tubular Medium PNM1H15AGXJ
250 W Metal Halide 31.5/14.3 3814/62.5 Ovoid/Tubular Medium PNM1H25AGXJ
400 W Metal Halide 35.3/16.0 3814/62.5 Tubular Medium PNM1H40AGXJ
400 W Metal Halide – – Ovoid/Tubular Large PNL1H40AGXJ
250 W Mercury Vapor 28.4/12.9 3814/62.5 Ovoid Medium PNM1M25AGXJ
400 W Mercury Vapor 30.4/13.8 3814/62.5 Ovoid/Tubular Medium PNM1M40AGXJ
With External Polycarbonate Weatherproof Protection
70 W HP Sodium 29.1/13.2 3814/62.5 Ovoid/Tubular Medium PNM1L70APXJ
150 W HP Sodium 30.9/14.0 3814/62.5 Ovoid/Tubular Medium PNM1L15APXJ
250 W HP Sodium 34.0/15.4 3814/62.5 Ovoid/Tubular Medium PNM1L25APXJ
400 W HP Sodium – – Ovoid/Tubular Large PNL1L40APXJ
150 W Metal Halide 30.9/14.0 3814/62.5 Ovoid/Tubular Medium PNM1H15APXJ
250 W Metal Halide 34.0/15.4 3814/62.5 Ovoid/Tubular Medium PNM1H25APXJ
400 W Metal Halide – – Ovoid/Tubular Large PNL1H40APXJ
250 W Mercury Vapor 30.9/14.0 3814/62.5 Ovoid Medium PNM1M25APXJ

Lighting: Enclosed and Gasketed — Floodlight


Accessories

Description Catalog Number


Fall Prevention Kit
FESCM20
(3.94"/1.2 m stainless steel chain) for M20 cable entry

Slipfitter Adapter — fits medium body GSF20

Slipfitter Adapter — fits large body GAM8SF


Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1169


© September 2010
PN Series Floodlight Dimensions and Photometric Data – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Dimensions

Size M Size L
7.76”/197 mm
7.36”/ 22.17”/563.0 mm 11.22”/
16.92”/460.0 mm 197 mm 285.0 mm
19.68”/500.0 mm
2.01”/
51.0 mm

22.17”/563.0 mm

343.0 mm
16.14”/410.0 mm

13.50”/
5.55”/
141.0 mm
5.55”/
141.0 mm (3) Mounting Holes
0.54”/13.8 mm
3.50”/
89.0 mm 3.50”/
2.01”/ 89.0 mm
51.0 mm
5.12”/
2.78”/ 130.0 mm 3.62”/
70.5 mm (3) Mounting Holes
0.55”/14.0 mm 5.12”/ 92.0 mm
130.0 mm 2.17”/ 3.50”/ 3.62”/
55.0 mm 89 mm 92.0 mm

Photometric Data

Lamps: 70 W High Pressure Sodium


Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121

Candelas
Degrees (0-180) (90-270) Total Luminaire Efficiency = 74.6%
0 487 487
Degrees
5 439 461
10 416 387
15 372 324
20 208 290
Lighting: Enclosed and Gasketed — Floodlight

25 129 294

30 116 319

35 111 318
40 101 289
45 86 193
50 70 150
55 84 141
60 62 132
65 22 88

70 9 15 Longitudinal
Transverse
Lighting

1170 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Corroflood™ 250/400 Stainless Steel Floodlights
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base
For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.

Class I, Division 2, Groups A, B, C, D


NEMA 4X
Suitable for Marine, Outdoor Salt Water
Location

Applications
• Powerful, efficient weatherproof lighting for medium and large
areas such as chemical plants, refineries, shipboard and marine
industrial process areas where severely corrosive agents are
present.
Features
• Compact in size, rugged and dependable.
• Easy to install and service.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Completely assembled fixture saves installation time and cost.
• Easily removable ballast tray.
• Hinged door.
• Seamless welded construction.
• Can be mounted in any position ranging from lens down to
horizontal, lens up.
• Stainless steel latches to allow relamping without tools.
Standard Materials
• Fixture body and trunnion arm: 316 stainless steel
• 16 gauge 316 stainless steel
• Lens: thermal-shock-resistant and tempered impact-resistant
glass
• Gasket: heavy-duty, high-temperature silicone rubber, firmly
seated
• Socket: heavy-duty, mogul base porcelain with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and spring-
loaded center contact
• Reflector: compound parabolic, double segment, finished
aluminum for optimum efficiency
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10794

For Class I, Division 2


Lamp Type Line Voltage T Rating Classified Duty and Marine

Lighting: Enclosed and Gasketed — Floodlight


Yoke Mount Catalog Number ➋
High Pressure Sodium
400 W HPS 120/208/240/277 350 SSF771L-MT-I/2
400 W HPS 120/277/347 350 SSF771L-TT-I/2 V
400 W HPS 480 350 SSF771L-48-I/2
250 W HPS 120/208/240/277 350 SSF671L-MT-I/2
250 W HPS 120/277/347 350 SSF671L-TT-I/2 V
250 W HPS 480 350 SSF671L-48-I/2
Pulse Start Metal Halide
400 W PSMH 120/208/240/277 350 SSF771P-MT-I/2
400 W PSMH 120/277/347 350 SSF771P-TT-I/2 V
400 W PSMH 480 350 SSF771P-48-I/2
250 W PSMH 120/208/240/277 350 SSF671P-MT-I/2
250 W PSMH 120/277/347 350 SSF671P-TT-I/2 V
250 W PSMH 480 350 SSF671P-48-I/2

Floodlights have 3/4” NPT tapped hub for power entry.


➊ Quartz emergency option NOT available for Class I, Division 2 fixtures. Contact your local sales representative for emergency quartz for non-classified areas.
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1171


© September 2010
Corroflood™ 250/400 Stainless Steel Floodlights
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base
For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.

Mounting Fittings and Accessories

Description Catalog Number


Crossarm Mounting Bracket — Has 180° horizontal adjustment—degree-
marked. Facilitates mounting floodlight to crossarm or other flat surface, or to
G-AM-8-WB. G-AM-8-CA
Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
Pipe or Wall Mount Bracket — Used with G-AM-8-CA. Clamps to 1” to
2-1/2” pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt
G-AM-8-WB
and crossarm bracket bolts. Malleable iron, zinc plated, chromate sealed, with
architectural bronze POLYESTER finish.
Poletop Slip-Fitter — 1-1/2” or 2” pipe size poletop tenons. Includes floodlight
yoke bolt, 3 locking bolts, and cord grip. Body is malleable iron—zinc plated,
G-SF20
chromate sealed, with cast aluminum cap. Assembly has architectural bronze
polyester finish.
Poletop Slip-Fitter — Slip-Fits 2” or 2-1/2” poletop tenons. Includes floodlight
yoke bolts, 3 locking bolts and cord grip. Malleable iron, zinc plated, chromate
G-AM-8-SF
sealed, with architectural bronze polyester finish.

Dimensions
17.25”/438.15 mm 7.00”/
177.8 mm
18.50”/469.9 mm
23.00”/584.2 mm

0.38”/9.1 mm
Dia. (2) Outer Holes
Lighting: Enclosed and Gasketed — Floodlight

0.56”/14.3 mm 1.75”/
Dia. Center Hole 44.45 mm
3.50”/
88.9 mm
18.50”/469.9 mm
Trunnion Mount
3.50”/88.9 mm
4.50”/
114.3 mm
6.00”/152.4 mm

4.00”/101.6 mm

Crossarm Mounting Bracket Pipe or Wall Mount Bracket Poletop Slip-Fitter Poletop Slip-Fitter
Lighting

1172 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Corroflood™ 250/400 Stainless Steel Floodlight Photometric Data
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base
For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.

Typical Footcandle Values † Electrical Specifications — All ballasts are CWA type
Line Voltage Starting Amps Operating Amps Total Watts
400 W High Pressure Sodium
120 3.30 3.80 465
208 1.80 2.20 465
240 1.60 1.90 465
277 1.40 1.70 465
347 1.00 1.32 464
480 0.80 1.00 465
400 W Pulse Start Metal Halide
120 3.50 4.00 454
208 2.00 2.30 454
240 1.25 2.00 454
277 1.50 1.75 454
347 1.10 1.35 452
480 0.90 1.00 454
250 W High Pressure Sodium
120 2.00 2.50 295
208 1.20 1.50 295
240 1.00 1.30 295
277 0.85 1.10 295
347 0.60 0.93 295
480 0.40 0.65 295
250 W Pulse Start Metal Halide
120 1.90 2.50 288
208 1.10 1.45 288
240 0.96 1.25 288
277 0.85 1.10 288
347 0.62 0.90 291

Lighting: Enclosed and Gasketed — Floodlight


480 0.45 0.60 285

Footcandles for Iso-Footcandle Lines


Mtg. Ht.
Ft/M A B C D E F A B C D E F
400 W HPS 250 W HPS
60/18.3 3.27 2.74 1.82 0.92 0.37 0.18 1.96 1.64 1.09 0.55 0.22 0.11
50/15.2 4.74 4.00 2.90 1.37 0.52 0.27 2.84 2.40 1.74 0.82 0.31 0.16
40/12.2 7.65 6.28 4.38 2.27 0.82 0.43 4.58 3.76 2.62 1.36 0.49 0.26
30/9.1 13.10 10.92 7.83 3.47 1.45 0.77 7.85 6.54 4.69 2.08 0.87 0.46
20/6.1 28.22 25.55 17.37 7.28 3.46 1.82 16.90 15.30 10.40 4.36 2.07 1.09
400 W PSMH 250 W PSMH
60/18.3 2.60 1.86 1.12 0.65 0.37 0.19 1.90 1.36 0.82 0.48 0.27 0.14
50/15.2 3.72 2.60 1.66 0.85 0.54 0.28 2.72 1.90 1.22 0.63 0.39 0.20
40/12.2 6.14 4.05 2.60 1.49 0.84 0.40 4.48 2.96 1.90 1.09 0.61 0.30
30/9.1 10.96 8.74 4.46 2.42 1.49 0.76 8.00 6.40 3.26 1.76 1.09 0.55
20/6.1 19.33 16.35 10.41 5.94 3.53 1.67 14.40 11.97 7.61 4.35 2.58 1.22

† Photometric charts available on request.


Lighting

◊ i.e., ratio of distance to height. Example: @ 20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1173


© September 2010
Wallmaster I/2 for Hazardous and Wet Locations — Class I, Division 2/Zone 2 V
cCSAus Certification Only. Enclosed and Gasketed. Integrally Ballasted. 70 W, 100 W, 150 W HPS

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2, Groups IIA, IIB, IIC

Applications
• Wall mounted luminaire suitable for outdoor applications.
• Areas where flammable gases are present under conditions
defines by NEC Class I, Division 2.
Features
• Attractive yet rugged design.
• Side hinged door allows unobstructed access to lamp and
wiring components.
• Built in stop limits door opening to 90° and protects the lens
from breakage.
• Latch mechanism: unique heavy-duty stainless steel latch
secures the cover assembly while allowing the luminaire to be
relamped without the use of tools.
• Prismatic tempered glass lens is thermal-shock- and impact-
resistant giving a soft diffused light.
• Installation is fast and easy.
• Luminaire is furnished with two plugged 1/2” conduit entries. A
1/2” knockout allows rear entry.
• Mogul base socket is heavy-duty porcelain with heavy gauge
brass nickel plated double lamp grip screw shell and spring
loaded center contacts.
• Aluminum reflector is designed for maximum efficiency.
• Standard finish is architectural
bronze tone baked epoxy.
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• CSAus Certified: 025428
• CSA Standard: C22.2 No. 250, C22.2 No. 137
• CSA Certified: 025428

Order using catalog numbering guide below.


Catalog Numbering Guide For Wallmaster I/2 Luminaires
GWN 70 L MT H R
Lighting: Enclosed and Gasketed — Floodlight

Series: Lamp Type: Ratings:


GWM - Wallmaster L - High Pressure Sodium H - Hazardous Location
F - Fluorescent

Wattage: Voltage: Options:


70 - 70 W HPS 48 - 480 E – Quartz Auxiliary Light (Non-
10 - 100 W HPS MT - 120/208/240/277 Hazardous HID only)
15 - 150 W HPS BU - 120-277, 50/60 Hz (Fluorescent G – Wire Guard
36 - Two 18 W PL-T Only) Q – Hazardous Photocontrol 120
52 - Two 26 W PL-T TT - 120/277/347 to 277 Vac (Class I, Div. 2)
64 - Two 32 W PL-T R – HRE (Hot Restrike for HID
only)
S – PE (Safety Starter for HID
only)
T – Tamper proof Latch
V – Polycarbonate Vandal Shield
Lighting

V CSA Certification only.

1174 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Wallmaster I/2 for Hazardous and Wet Locations — Class I, Division 2/Zone 2 V
cCSAus Certification Only. Enclosed and Gasketed. Integrally Ballasted. 70 W, 100 W, 150 W HPS

Class I, Division 2, Groups A, B, C, D


Class I, Zone 2, Groups IIA, IIB, IIC

“T” Numbers for Wallmaster I/2 Fixtures


Lamp Lamp Supply Maximum Ambient Class I, Division 2
Watts Type Wire °F/°C Temperature °F/°C Class I, Zone 2
70 HPS 257/125 104/40 T2D
100 HPS 257/125 77/25 T2C
150 HPS 257/125 77/25 T2A
104/40
36 Fluorescent 257/125 T3
131/55
104/40
52 Fluorescent 257/125 T3
131/55
104/40
64 Fluorescent 257/125 T3
131/55

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
“T”
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Number
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

Accessories
Description Catalog Number

Guard - Stainless steel plated GWMWG

Lighting: Enclosed and Gasketed — Floodlight


Vandal Shield - UV stabilized polycarbonate. Can be used with guard. GWMLS

Clear Replacement Lens GWML


Dimensions
5.44”/
138.1 mm
14.00”/355.6 mm

12.13”/
308.0 mm
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1175


© September 2010
TVA Obstruction, Approach and Boundary Luminaires V
CSA Certification Only
For use with Threaded Rigid Metal Conduit and IMC.
Lighting

Class I, Division 2 versions available

Applications
Lighting: Enclosed and Gasketed — Visual Signal

• Transport Canada approved TVA490 series low intensity


obstruction, approach or boundary light.
• TVA490 series obstruction lights are suitable for use on
communication towers or other tall structures and buildings.
Features
• TVA obstruction lights are available with one or two lamps.
• Models are equipped with rainports in the globe holder which
keeps the wiring chamber dry.
• TVA obstruction lights are rugged cast aluminum construction.
• Two lamp fixtures are furnished with pre-wired sockets.
• Utilizes Type A-21 116 W clear traffic signal lamp.
• A corrosion resistant finish protects TVA fixtures. TVA490
obstruction lights are approved for use by Transport Canada.
• Engineered for easy and safe maintenance, TVA490 fixtures are
serviced without tools: TVA 1490
(1) The globe holder is secured with a captive thumb screw
(2) a one-eighth turn twist removes the globe and lobe holder
(3) the assembly is hung from a safety chain freeing both hands
• Fresnel glass lenses and three lamp holder positions permit
use of TVA490 fixtures on structures below 50 feet/15.2 meters,
from 50 to 100 feet / 15.2 to 30.5 meters, and over
100 feet/30.5 meters.
• A plugged 1" side hub and a 1-1/4" bottom hub provide
conduit entry.
• Transfer and failure alarm relays for both one and two
lamp fixtures.
• Pilot light assembly contains a red pilot light to indicate lamp
failure.
Standard Materials
• TVA bodies: copperfree (4/10 of 1% max.) aluminum TVA 2490
• Lamp holders: porcelain
• Transfer and failure alarm, pilot light assembly: ferrous alloy
enclosure
• Supply wire requirement: 90 ºC
Standard Finish
• TVA490: international orange epoxy clad finish
• Transfer failure alarm, pilot light assembly: triple coat – (1) zinc
electroplate, (2) chromate and (3) aluminum polymer enamel
Certifications and Compliances
• CSA Standard: C22.2 No. 250
• CSA Certified: 009349

V CSA Certification only.

1176 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
TVA Obstruction, Approach and Boundary Luminaires V
CSA Certification Only
For use with Threaded Rigid Metal Conduit and IMC.

Lighting
Class I, Division 2 versions available

Lighting: Enclosed and Gasketed — Visual Signal


Hub Size (Inches)
Description Side Bottom Catalog Number
TVA490 Obstruction, Approach and Boundary Lights
Type A-21 Clear Traffic Signal Light 116 W
One Lamp Fixtures
Obstruction with Red Globe — 1 TVA1490
Approach with Yellow Globe — 1 TVA1490Y
Boundary with Clear Globe — 1 TVA1490C
One Lamp Haz. Loc. Fixtures
Obstruction with Red Globe — 1 TVA1490H
Approach with Yellow Globe — 1 TVA1490YH
Boundary with Clear Globe — 1 TVA1490CH
Two Lamp Fixtures
Obstruction with Red Globe 1 1-1/4 ① TVA2490
Approach with Yellow Globe 1 1-1/4 ① TVA2490Y
Boundary with Clear Globe 1 1-1/4 ① TVA2490C
Two Lamp Haz. Loc. Fixtures
Obstruction with Red Globe 1 1-1/4 ① TVA2490H
Approach with Yellow Globe 1 1-1/4 ① TVA2490YH
Boundary with Clear Globe 1 1-1/4 ① TVA2490CH
TVA490 Replacement Parts
Mounting Fittings
With Globe Holder and Lamp Socket
Single Lamp — 1 TVA1400

Two Lamp 1 1-1/4 TVA2400

Globes
Fresnel
Red V-990R
Aviation yellow V-990Y
Clear V-990C

Lamp Socket

Porcelain — Medium Base V-1025

Globe Gasket

Neoprene V-2055G

Wiring Chamber Cover

Cover assembly for two lamp fixture wiring


V-2010
chamber. With gasket and screws

① To order with 1/4" to 1" reducer in the bottom hub add suffix -RB100.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1177


© September 2010
TVA Obstruction, Approach and Boundary Luminaire Accessories V
CSA Certification Only
For use with Threaded Rigid Metal Conduit and IMC.
Lighting

Class I, Division 2 versions available


Lighting: Enclosed and Gasketed — Visual Signal

Hub Size Catalog


Description (Inches) Number
Lamp Failure Alarm

In the event of both lamps failing in the obstruction light an 1 FDC-32R2


alarm circuit is triggered.
Weather-proof enclosure is furnished with feed-thru hubs.
120 Vac, 50/60 Hz
Relay drops out at 0.6 amps.

Transfer Relay and Lamp Failure Alarm


In the event of a lamp failure, power is transferred to the 1 FDC-32R1
standby lamp and an alarm circuit is activated.
Weather-proof enclosure is furnished with feed-thru hubs.
120 Vac, 50/60 Hz
Relay drops out at 0.6 amps.

Pilot Light Assembly


Connected to failure alarm to indicate lamp failure. 1 FD-3J1
Red pilot light.
6S6 candelabra base lampholder.
Dead end enclosure.

Photocell (Non-Hazardous)
Comes installed in FDO type enclosure, ready for installation. FS601
120 V Only.
(Class I, Division 2)
As above, c/w Encapsulated Photocell for Hazardous Area FS601D2
installation. 120 V Only.
Flasher Assembly
Comes installed in FDO type enclosure, ready for installation. TVA-FL
2500 W Rated, 200 A Max. In-Rush FAA approved 30 FPM
Flash Rate.

V CSA Certification only.

1178 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
TVA Obstruction, Approach and Boundary Luminaire Dimensions V
CSA Certification Only
For use with Threaded Rigid Metal Conduit and IMC.

Lighting
Lighting: Enclosed and Gasketed — Visual Signal
Dimensions (Inches/Millimeters)
Description A B Catalog Number
One Lamp
Single 10.00/254.0 4.25/107.95 TVA1490

Two Lamp
Twin 10.75/273.05 13.75/349.25 TVA2490

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1179


© September 2010
Stylmaster™ Strobe Luminaires
Enclosed and Gasketed
Lighting

NEC: Pendant Mount NEC: Ceiling and Wall Bracket Mount CEC: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G NEMA 3R, 4 Class II, Division 1 and 2, Groups E, F, G
Class III Class III
NEMA 3R, 4 CSA Enclosure 3
Marine Outside Type (Saltwater)

Applications
Lighting: Enclosed and Gasketed — Visual Signal

• Enclosed and gasketed fixtures suitable for use in:


— Marine and wet locations
— Industrial processing
— Chemical processing
— Areas where flammable gases and vapors are present under
conditions defined by NEC Class I, Division 2; Class II,
Division 1 and 2; and Class III
• For use in areas where audible signals cannot be heard.
• Used to warn of unsafe conditions and other communication
needs.
• Fixtures are also suited for use in non-hazardous areas where
there are:
— Severe weather conditions
— Excessive moisture, dirt, dust
— Corrosive atmospheres
— High ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Marine applications
Features
• Modern styling, with clean-line mounting hood and prismatic
glass globe, plus optional guard.
• Globe seats firmly against silicone gasket in mounting
hood to keep out dirt and moisture. Full threads eliminate “cross
threading.”
• Optional guard protects glass from damage and has
exclusive snap-on attachment feature for quick installation Fixtures are suitable for mounting in any position – including globe up or
and fast servicing. globe down – utilizing pendant, ceiling or wall bracket type mounts.
• Fixtures operate safely in high ambient temperatures.
• Strobe: 65 flashes per minute. 800,000 peak candlepower.
• Fixtures are complete with lamp.
• Lens available in five colors: red, amber, blue, green and
clear (factory installed).
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Fixture is suitable for mounting globe up or globe down utilizing
pendant, ceiling or wall bracket type mounts.
• Minimum operating temperature is -13 °F/-25 °C.
Standard Materials
• Mounting hoods: copperfree (4/10 of 1% max.) aluminum
• Guards: pressure cast copperfree (4/10 of 1% max.) aluminum
• Globes: prismatic glass
Standard Finish
• Mounting hoods and guards: powder coat epoxy
Certifications and Compliances
• UL Standard: UL 1203, UL 1638
• UL Listed: E207738
• CSA Standard: C22.2 No. 25
• cUL Listed: E207738

V CSA Certification only.

1180 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Stylmaster™ Strobe Luminaires
Enclosed and Gasketed

Lighting
NEC: Pendant Mount NEC: Ceiling and Wall Bracket Mount CEC: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G NEMA 3R, 4 Class II, Division 1 and 2, Groups E, F, G
Class III Class III
NEMA 3R, 4 CSA Enclosure 3
Marine Outside Type (Saltwater)

Lighting: Enclosed and Gasketed — Visual Signal


Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For VP Stylmaster Strobe Luminaires
VP A S 75 120AC CL G

Series: Lamp Type: Voltage Current: Options:


VP - Stylmaster S - Strobe 120AC - 120 Vac G - Guard
240AC - 240 Vac
1248DC - 12-48 Vdc
24PDC - 24 Vdc ①
250DC - 250 Vdc
Mounting Hood: Hub Size: Globe:
A - Pendant 75 - 3/4” CL - Clear
X - Ceiling AM - Amber
WB - Wall Bracket BL - Blue
GR - Green
RE - Red

Technical Data: Thermal Suitability of Stylmaster Strobe

Operating Temperatures
Ambient Class I, Division 2 Groups A,B,C,D Class II, Division 1& 2 and Class III
Temp. (°F/°C) Pendant, Ceiling and Wall Bracket Pendant Mount
104/40 T2A T4A
131/55 T2 T4A
149/65 T1 T4

Operating Temperatures Represent the Maximum Internal Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.

“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101-
Range 86-100 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120
(°C)

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
① Diode Polarized (current limiter supplied as standard).
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1181


© September 2010
Stylmaster™ Strobe Luminaires
Enclosed and Gasketed
Lighting

NEC: Pendant Mount NEC: Ceiling and Wall Bracket Mount CEC: V
Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G NEMA 3R, 4 Class II, Division 1 and 2, Groups E, F, G
Class III Class III
NEMA 3R, 4 CSA Enclosure 3
Marine Outside Type (Saltwater)
Lighting: Enclosed and Gasketed — Visual Signal

Volts Wt. (lbs/kg) Catalog Number ①


Pendant — Rigid Conduit One Hub 3/4” NPT
120 Vac VPAS75120ACCL
240 Vac VPAS75240ACCL
250 Vdc 4.5/2.0 VPAS75250DCCL
12-48 Vdc VPAS751248DCCL
24 Vdc VPAS7524PDCCL ②

Ceiling — Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs
120 Vac VPXS75120ACCL
240 Vac VPXS75240ACCL
250 Vdc 5.3/2.4 VPXS75250DCCL
12-48 Vdc VPXS751248DCCL
24 Vdc VPXS7524PDCCL ②

Wall Bracket — Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs
120 Vac VPWBS75120ACCL
240 Vac VPWBS75240ACCL
250 Vdc 6.4/2.9 VPWBS75250DCCL
12-48 Vdc VPWBS751248DCCL
24 Vdc VPWBS7524DCCL ②

Optional Aluminum Guard

1.0/0.5 VPGU-1

① Catalog numbers shown are supplied with clear lens. To order colored lens, replace the last digits of catalog number CL with AM for amber, BL for blue,
GR for green or RE for red.
② Diode Polarized (current limiter supplied as standard).
V CSA Certification only.

1182 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Stylmaster™ Strobe Luminaire Replacement Parts and Dimensions
Enclosed and Gasketed

Lighting
Lighting: Enclosed and Gasketed — Visual Signal
Replacement Parts
Fixture Type Lamp Type Voltage Base Type Catalog Number
Replacement Lamps Strobe Xenon All Octal Socket S865

S865

Catalog Insert
Glass Globe Number (in addition to Glass Globe)
Replacement Globes and Inserts Clear VPGL-1HR Clear 59606060000
Amber 59606060001
Blue 59606060002
Green 59606060003
Red 59606060004

Dimensions

Pendant Mount Ceiling Mount Wall Mount


10.63"/
270.0 mm
7.00"/ 7.00"/ 8.75"/
177.8 mm 177.8 mm 222.3 mm
4.06"/ 5.25"/
103.1mm 133.4mm

3.56"/
3.05"/ 90.4 mm 3.31"/
77.5 mm 84.1mm

9.13"/ 9.13"/
231.9mm 9.39"/
231.9mm 238.5 mm
6.08"/
154.4mm

1.88” / 1.88” /
47.8 mm 47.8 mm
4.75”/ 4.75”/
120.7 mm 120.7 mm
4.06” / 4.06” /
103.1 mm 103.1 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1183


© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• Auxiliary (emergency) lighting should be used to provide a
lighted means of egress for personnel in walkways, catwalks,
stairs, doorways, tunnels, ramps and aisles.
• Auxiliary (emergency) lighting should be used to provide
Lighting

“instant on” illumination during power failures.


• Enclosed and gasketed fixtures are suitable for normal
and emergency use in wet locations and in a wide range
of industrial, chemical processing and other areas where
flammable gases and vapors or combustible dusts are
present under conditions defined by NEC Class I, Division 2;
Class II, Division 1 and 2; and Class III.
• Suitability includes listing for normal and emergency use
Lighting: Enclosed and Gasketed — Emergency

where there may be simultaneous exposure to combustible Prismatic Glass Globe 12” Glass Refractor Enclosed Reflector
dusts and flammable gases and vapors.
• Fixtures are also well suited for normal and emergency
use in non-hazardous areas where severe weather
conditions, excessive moisture, dirt, dust or corrosive
atmospheres are encountered.
• Typical applications include pulp and paper mills, processing • “Instant on” nature of the fluorescent light source prevents the
plants, chemical plants, oil refineries, foundries, manufacturing possibility of a complete blackout due to power failure.
plants and storage areas. • Fixture (26 W or 52 W) is available for emergency operation (one
battery pack provides illumination only during power outage).
Features • Fixture (26 W or 52 W) is available for continuous operation
• Modular design allows scores of fixture component (one AC ballast permits illumination when AC power is on and
combinations to meet installation and lighting needs. one battery pack permits illumination when AC power
• Choice of optical assemblies: (1) prismatic globe; (2) enclosed is interrupted).
reflector with sealed lens; and (3) Type V or Type II closed • Fixture (26 W, 52 W, 64 W or 84 W) is available for
prismatic refractor, with or without guard. semi-continuos operation (one AC ballast permits illumination
• Fluorescent light source reduces energy costs. when power is on and one battery pack permits one lamp
• Fluorescent lamp life of 10,000 hours reduces relamping illumination when AC power is interrupted).
costs compared to incandescent. • For electrical protection, a ground wire is provided on each
• Mounting hoods include cone-shaped pendant, standard Mercmaster to bond hood and ballast housing.
pendant, ceiling and wall (tapped for 3/4” or 1” NPT), 25° • Minimum operating temperature: 0 °C/32 °F.
angle stanchion and straight stanchion (both tapped for • Maximum operating temperature: 40 °C/104 °F.
1-1/4” or 1-1/2” NPT).
• Cone hood fixtures for pendant mounting shed dust, dirt Battery Pack Information
and combustible fibers. Inhibits build-up that “insulates” • Sealed, maintenance-free, high-temperature nickel-cadmium.
fixture and slows heat transfer. Also provides increased • Solid state chargers sealed within the ballast case.
surface area for more effective heat dissipation. • 10 year life expectancy.
• Reflector choice includes standard dome and 30° angle • Wiring instructions for “Push-To-Test” button are supplied
types, both made of fiberglass reinforced white polyester. with fixture.
Highly resistant to unusually corrosive applications. Reflectors • Remote “Push-To-Test” switch is available to verify emergency
are vented for cooler, dirt-free operation and maintained lumen operation (order separately, see F3-82).
output. They secure to ballast housing with stainless steel • Red indicator light is provided with each battery pack to indicate
screws, threading into stainless steel inserts. when the battery is charging.
• For high corrosion resistance, fixture housing, mounting
hoods and guards are diecast copperfree (4/10 of 1% max.)
Standard Materials
aluminum with baked epoxy finish, electrostatically applied for • Mounting hoods, ballast bodies and guard: diecast
uniformity. cooper-free aluminum (less than 4/10 of 1%)
All exposed hardware is stainless steel. • Exposed hardware: stainless steel; latch assemblies have
• Hinge has high lip for added safety during installation stainless steel bolt and captive nut; reflectors and guards attach
and servicing. Hinge and bolt construction assures 360° with stainless steel screws threading into stainless steel inserts
compression at all points on ballast housing gasket for • Reflectors: fiberglass reinforced white polyester
positive sealing. Swing-away design of captive bolt and • Globe: heat- and im­pact-re­sist­ant in­ter­nal­ly flut­ed glass
nut simplifies servicing. • Refractors: pris­mat­ic glass
• Body gaskets and globe gaskets are high-temperature • Enclosed re­flec­tor: etched alu­mi­num with sealed,
silicone rubber. tem­pered heat- and im­pact-re­sist­ant lens
• All Mercmaster III mounting hoods have provision for easy • Guards: stain­less steel
field installation of fuses in fixtures (see fuse kit listing in this • Breather: stainless steel
catalog section).

1184 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Standard Finishes Certifications and Compliances


• Mounting hoods, ballast bodies, guards: baked gray • UL Standard: UL 1598, UL 924, UL 844
epoxy-clad finish, electrostatically applied for complete, • UL Listed: E10444
uniform surface protection • NFPA101, Life Safety Code
• Reflectors: white polyester finish

Lighting
Options
• Fuses can be field-installed on Mercmaster III fixtures. Kit
includes fuse block, wire connectors and screws for attaching to
mounting hood.

Lighting: Enclosed and Gasketed — Emergency


Order using catalog numbering guide below or select catalog number from tables on following pages.

Catalog Numbering Guide


KP A F 26 C 2 G4 G BU L

Series: Lamp Type: Circuit Type: Optic: Voltage:


KP - Class I, F - Fluorescent C - Continuous G4 - Globe 120 through 277 Volt
Division 2 Operation R - Enclosed 50/60 Hz
Groups A,B,C,D (provided with 1 Reflector with
Class II, Division 1 AC Ballast and 1 Sealed Lens
and 2 Battery Pack). J2 - NEMA II
Groups E,F,G 26 W and 52 W Refractor
Class III E- Emergency J5 - NEMA V
Operation Refractor
(provided with 1
Battery Pack).
26 W and 52 W
only
S - Semi-
Continuous
(provided with 1
AC Ballast and 1
Battery Pack).
26 W, 52 W, 64 W
and 84 W

Mounting Hood: Lamp Wattage: Hub Size: Guard Option: Lamps:


A - Pendant 26 - 26 W (Two 13 W Lamps) 2 - 3/4” G - Guard L - Lamps provided
C - Ceiling 52 - 52 W (Two 26 W Lamps) 3 - 1” N - No Guard
D - Pendant Cone 64 - 64 W (Two 32 W Lamps) 4 - 1-1/4”
F - Flexible Pendant 84 - 84 W (Two 42 W Lamps) 5 - 1-1/2”
R - 90° Stanchion
S - 25° Stanchion
W - Wall

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1185


© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Illustrated Features
Lighting
Lighting: Enclosed and Gasketed — Emergency

Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Hood/Ballast Gasket
Aluminum Inner Reflector Silicone rubber gasket seals out moisture,
Stainless Steel Inserts dirt and dust. Stays flexible, withstands
Solid aluminum inner reflector improves
Ballast bodies have stainless steel high temperatures. Closure design
photometric efficiency.
threaded inserts to receive stainless steel assures uniform gasket compression.
screws for reflectors and guard. Prevents
Epoxy Finish
"freezing”, allowing guards and reflectors Electrical Protection
Ballast housing, hoods and guards are
to be easily removed and replaced at any Ground wire provided to bond mounting
copperfree aluminum with epoxy powder
time, without damage to the housing. hood to ballast housing.
coat finish.

Prismatic Glass Globes, Refractors


"Safety" High and Enclosed Reflector
Hinge Heat-resistant globes, refractors and
Extra-high hinge enclosed reflector thread into ballast
provides additional housing and seal against a high
protection against temperature silicone rubber gasket.
accidental
ballast housing
disengagement
during installation
or maintenance. Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.

1186 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Emergency Battery Pack Technical Data
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Electrical Specification for AC Operation

Fixture Wattage Line Voltage (V) Frequency (Hz) Type of Ballast Line Amps (A) Maximum Wattage (W/W) Catalog Number
26 W (2X 13 W) 120-277 50/60 Electronic (PLT) 0.26-0.11 30/30 KPBC26FBU

Lighting
26 W (2X 13 W) 120-277 50/60 Electronic (PLT) 0.26-0.11 30/30 KPBE26FBU
26 W (2X 13 W) 120-277 50/60 Electronic (PLT) 0.26-0.11 30/30 KPBS26FBU
52 W (2X 26 W) 120-277 50/60 Electronic (PLT) 0.46-0.20 56/55 KPBC52FBU
52 W (2X 26 W) 120-277 50/60 Electronic (PLT) 0.46-0.20 56/55 KPBE52FBU
52 W (2X 26 W) 120-277 50/60 Electronic (PLT) 0.46-0.20 56/55 KPBS52FBU

Lighting: Enclosed and Gasketed — Emergency


64 W (2X 32 W) 120-277 50/60 Electronic (PLT) 0.58-0.26 69/67 KPBS64FBU
84 W (2X 42 W) 120-277 50/60 Electronic (PLT) 0.76-0.32 91/90 KPBS84FBU

Thermal Performance of Mercmaster III Emergency Battery Pack Fixtures

Ambient Supply Wire


Hazardous Lamp Temp. Globe w/ Enclosed Suitability
Rating Watts (°F/°C) Group Globe Reflector Refractor Reflector (°F/°C)
26 W (2 x 13 W) 104/40 A,B,C,D T2D T2D T2D T2D 167/75
52 W (2 x 26 W) 104/40 A,B,C,D T2D T2D T2D T2D 167/75
Class I, Division 2
64 W (2 x 32 W) 104/40 A,B,C,D T2D T2D T2D T2D 167/75
84 W (2 x 42 W) 104/40 A,B,C,D T2D T2D T2D T2D 167/75
26 W (2 x 13 W) 104/40 E,F,G T3B T3B T4 T4A 194/90
52 W (2 x 26 W) 104/40 E,F,G T3B T3B T4 T4A 194/90
Class II, Division 1
64 W (2 x 32 W) 104/40 E,F,G T3B T3B T4 T4A 194/90
84 W (2 x 42 W) 104/40 E,F,G T3B T3B T4 T4A 194/90
26 W (2 x 13 W) 104/40 — T1 T1 T2 T2B 230/110
Simultaneous
Exposure 52 W (2 x 26 W) 104/40 — T1 T1 T2 T2B 230/110
Class I, Division 2 / 64 W (2 x 32 W) 104/40 — T1 T1 T2 T2B 230/110
Class II, Division 1
84 W (2 x 42 W) 104/40 — T1 T1 T2 T2B 230/110

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and Maximum
Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101-
Range 86-100 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120
(°C)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1187


© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Catalog Numbers
Lamp Hub Size Mode of with Type V 12” Refractor with Enclosed
Watts (Inches) Operation Volts Hz with Globe ➊➋ ➊➋➌ Reflector ➊➋➌
Pendant ➍ 26 3/4 Continuous 120-277 50/60 KPAF26C2G4NBUL KPAF26C2J5NBUL KPAF26C2RNBUL
Lighting

26 1 Continuous 120-277 50/60 KPAF26C3G4NBUL KPAF26C3J5NBUL KPAF26C3RNBUL


26 3/4 Semi-Continuous 120-277 50/60 KPAF26S2G4NBUL KPAF26S2J5NBUL KPAF26S2RNBUL
26 1 Semi-Continuous 120-277 50/60 KPAF26S3G4NBUL KPAF26S3J5NBUL KPAF26S3RNBUL
26 3/4 Emergency 120-277 50/60 KPAF26E2G4NBUL KPAF26E2J5NBUL KPAF26E2RNBUL
26 1 Emergency 120-277 50/60 KPAF26E3G4NBUL KPAF26E3J5NBUL KPAF26E3RNBUL
Lighting: Enclosed and Gasketed — Emergency

Pendant Cone 26 3/4 Continuous 120-277 50/60 KPDF26C2G4NBUL KPDF26C2J5NBUL KPDF26C2RNBUL


26 1 Continuous 120-277 50/60 KPDF26C3G4NBUL KPDF26C3J5NBUL KPDF26C3RNBUL
26 3/4 Semi-Continuous 120-277 50/60 KPDF26S2G4NBUL KPDF26S2J5NBUL KPDF26S2RNBUL
26 1 Semi-Continuous 120-277 50/60 KPDF26S3G4NBUL KPDF26S3J5NBUL KPDF26S3RNBUL
26 3/4 Emergency 120-277 50/60 KPDF26E2G4NBUL KPDF26E2J5NBUL KPDF26E2RNBUL
26 1 Emergency 120-277 50/60 KPDF26E3G4NBUL KPDF26E3J5NBUL KPDF26E3RNBUL
Ceiling 26 3/4 Continuous 120-277 50/60 KPCF26C2G4NBUL KPCF26C2J5NBUL KPCF26C2RNBUL
26 1 Continuous 120-277 50/60 KPCF26C3G4NBUL KPCF26C3J5NBUL KPCF26C3RNBUL
26 3/4 Semi-Continuous 120-277 50/60 KPCF26S2G4NBUL KPCF26S2J5NBUL KPCF26S2RNBUL
26 1 Semi-Continuous 120-277 50/60 KPCF26S3G4NBUL KPCF26S3J5NBUL KPCF26S3RNBUL
26 3/4 Emergency 120-277 50/60 KPCF26E2G4NBUL KPCF26E2J5NBUL KPCF26E2RNBUL
26 1 Emergency 120-277 50/60 KPCF26E3G4NBUL KPCF26E3J5NBUL KPCF26E3RNBUL
Wall 26 3/4 Continuous 120-277 50/60 KPWF26C2G4NBUL KPWF26C2J5NBUL KPWF26C2RNBUL
26 1 Continuous 120-277 50/60 KPWF26C3G4NBUL KPWF26C3J5NBUL KPWF26C3RNBUL
26 3/4 Semi-Continuous 120-277 50/60 KPWF26S2G4NBUL KPWF26S2J5NBUL KPWF26S2RNBUL
26 1 Semi-Continuous 120-277 50/60 KPWF26S3G4NBUL KPWF26S3J5NBUL KPWF26S3RNBUL
26 3/4 Emergency 120-277 50/60 KPWF26E2G4NBUL KPWF26E2J5NBUL KPWF26E2RNBUL
26 1 Emergency 120-277 50/60 KPWF26E3G4NBUL KPWF26E3J5NBUL KPWF26E3RNBUL
90° Stanchion 26 1-1/4 Continuous 120-277 50/60 KPRF26C4G4NBUL KPRF26C4J5NBUL KPRF26C4RNBUL
26 1-1/2 Continuous 120-277 50/60 KPRF26C5G4NBUL KPRF26C5J5NBUL KPRF26C5RNBUL
26 1-1/4 Semi-Continuous 120-277 50/60 KPRF26S4G4NBUL KPRF26S4J5NBUL KPRF26S4RNBUL
26 1-1/2 Semi-Continuous 120-277 50/60 KPRF26S5G4NBUL KPRF26S5J5NBUL KPRF26S5RNBUL
26 1-1/4 Emergency 120-277 50/60 KPRF26E4G4NBUL KPRF26E4J5NBUL KPRF26E4RNBUL
26 1-1/2 Emergency 120-277 50/60 KPRF26E5G4NBUL KPRF26E5J5NBUL KPRF26E5RNBUL
25° Stanchion 26 1-1/4 Continuous 120-277 50/60 KPSF26C4G4NBUL KPSF26C4J5NBUL KPSF26C4RNBUL
26 1-1/2 Continuous 120-277 50/60 KPSF26C5G4NBUL KPSF26C5J5NBUL KPSF26C5RNBUL
26 1-1/4 Semi-Continuous 120-277 50/60 KPSF26S4G4NBUL KPSF26S4J5NBUL KPSF26S4RNBUL
26 1-1/2 Semi-Continuous 120-277 50/60 KPSF26S5G4NBUL KPSF26S5J5NBUL KPSF26S5RNBUL
26 1-1/4 Emergency 120-277 50/60 KPSF26E4G4NBUL KPSF26E4J5NBUL KPSF26E4RNBUL
26 1-1/2 Emergency 120-277 50/60 KPSF26E5G4NBUL KPSF26E5J5NBUL KPSF26E5RNBUL
NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.

1188 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Catalog Numbers
Lamp Hub Size Mode of with Type V 12” Refractor with Enclosed
Watts (Inches) Operation Volts Hz with Globe ➊➋ ➊➋➌ Reflector ➊➋➌
Pendant ➍ 52 3/4 Continuous 120-277 50/60 KPAF52C2G4NBUL KPAF52C2J5NBUL KPAF52C2RNBUL

Lighting
52 1 Continuous 120-277 50/60 KPAF52C3G4NBUL KPAF52C3J5NBUL KPAF52C3RNBUL
52 3/4 Semi-Continuous 120-277 50/60 KPAF52S2G4NBUL KPAF52S2J5NBUL KPAF52S2RNBUL
52 1 Semi-Continuous 120-277 50/60 KPAF52S3G4NBUL KPAF52S3J5NBUL KPAF52S3RNBUL
52 3/4 Emergency 120-277 50/60 KPAF52E2G4NBUL KPAF52E2J5NBUL KPAF52E2RNBUL
52 1 Emergency 120-277 50/60 KPAF52E3G4NBUL KPAF52E3J5NBUL KPAF52E3RNBUL

Lighting: Enclosed and Gasketed — Emergency


Pendant Cone 52 3/4 Continuous 120-277 50/60 KPDF52C2G4NBUL KPDF52C2J5NBUL KPDF52C2RNBUL
52 1 Continuous 120-277 50/60 KPDF52C3G4NBUL KPDF52C3J5NBUL KPDF52C3RNBUL
52 3/4 Semi-Continuous 120-277 50/60 KPDF52S2G4NBUL KPDF52S2J5NBUL KPDF52S2RNBUL
52 1 Semi-Continuous 120-277 50/60 KPDF52S3G4NBUL KPDF52S3J5NBUL KPDF52S3RNBUL
52 3/4 Emergency 120-277 50/60 KPDF52E2G4NBUL KPDF52E2J5NBUL KPDF52E2RNBUL
52 1 Emergency 120-277 50/60 KPDF52E3G4NBUL KPDF52E3J5NBUL KPDF52E3RNBUL
Ceiling 52 3/4 Continuous 120-277 50/60 KPCF52C2G4NBUL KPCF52C2J5NBUL KPCF52C2RNBUL
52 1 Continuous 120-277 50/60 KPCF52C3G4NBUL KPCF52C3J5NBUL KPCF52C3RNBUL
52 3/4 Semi-Continuous 120-277 50/60 KPCF52S2G4NBUL KPCF52S2J5NBUL KPCF52S2RNBUL
52 1 Semi-Continuous 120-277 50/60 KPCF52S3G4NBUL KPCF52S3J5NBUL KPCF52S3RNBUL
52 3/4 Emergency 120-277 50/60 KPCF52E2G4NBUL KPCF52E2J5NBUL KPCF52E2RNBUL
52 1 Emergency 120-277 50/60 KPCF52E3G4NBUL KPCF52E3J5NBUL KPCF52E3RNBUL
Wall 52 3/4 Continuous 120-277 50/60 KPWF52C2G4NBUL KPWF52C2J5NBUL KPWF52C2RNBUL
52 1 Continuous 120-277 50/60 KPWF52C3G4NBUL KPWF52C3J5NBUL KPWF52C3RNBUL
52 3/4 Semi-Continuous 120-277 50/60 KPWF52S2G4NBUL KPWF52S2J5NBUL KPWF52S2RNBUL
52 1 Semi-Continuous 120-277 50/60 KPWF52S3G4NBUL KPWF52S3J5NBUL KPWF52S3RNBUL
52 3/4 Emergency 120-277 50/60 KPWF52E2G4NBUL KPWF52E2J5NBUL KPWF52E2RNBUL
52 1 Emergency 120-277 50/60 KPWF52E3G4NBUL KPWF52E3J5NBUL KPWF52E3RNBUL
90° Stanchion 52 1-1/4 Continuous 120-277 50/60 KPRF52C4G4NBUL KPRF52C4J5NBUL KPRF52C4RNBUL
52 1-1/2 Continuous 120-277 50/60 KPRF52C5G4NBUL KPRF52C5J5NBUL KPRF52C5RNBUL
52 1-1/4 Semi-Continuous 120-277 50/60 KPRF52S4G4NBUL KPRF52S4J5NBUL KPRF52S4RNBUL
52 1-1/2 Semi-Continuous 120-277 50/60 KPRF52S5G4NBUL KPRF52S5J5NBUL KPRF52S5RNBUL
52 1-1/4 Emergency 120-277 50/60 KPRF52E4G4NBUL KPRF52E4J5NBUL KPRF52E4RNBUL
52 1-1/2 Emergency 120-277 50/60 KPRF52E5G4NBUL KPRF52E5J5NBUL KPRF52E5RNBUL
25° Stanchion 52 1-1/4 Continuous 120-277 50/60 KPSF52C4G4NBUL KPSF52C4J5NBUL KPSF52C4RNBUL
52 1-1/2 Continuous 120-277 50/60 KPSF52C5G4NBUL KPSF52C5J5NBUL KPSF52C5RNBUL
52 1-1/4 Semi-Continuous 120-277 50/60 KPSF52S4G4NBUL KPSF52S4J5NBUL KPSF52S4RNBUL
52 1-1/2 Semi-Continuous 120-277 50/60 KPSF52S5G4NBUL KPSF52S5J5NBUL KPSF52S5RNBUL
52 1-1/4 Emergency 120-277 50/60 KPSF52E4G4NBUL KPSF52E4J5NBUL KPSF52E4RNBUL
52 1-1/2 Emergency 120-277 50/60 KPSF52E5G4NBUL KPSF52E5J5NBUL KPSF52E5RNBUL
NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1189


© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Catalog Numbers
Lamp Hub Size Mode of with Type V 12” Refractor with Enclosed
Watts (Inches) Operation Volts Hz with Globe ➊➋ ➊➋➌ Reflector ➊➋➌
Pendant ➍ 64 3/4 Semi-Continuous 120-277 50/60 KPAF64S2G4NBUL KPAF64S2J5NBUL KPAF64S2RNBUL
Lighting

64 1 Semi-Continuous 120-277 50/60 KPAF64S3G4NBUL KPAF64S3J5NBUL KPAF64S3RNBUL


Lighting: Enclosed and Gasketed — Emergency

Pendant Cone 64 3/4 Semi-Continuous 120-277 50/60 KPDF64S2G4NBUL KPDF64S2J5NBUL KPDF64S2RNBUL

64 1 Semi-Continuous 120-277 50/60 KPDF64S3G4NBUL KPDF64S3J5NBUL KPDF64S3RNBUL

Ceiling 64 3/4 Semi-Continuous 120-277 50/60 KPCF64S2G4NBUL KPCF64S2J5NBUL KPCF64S2RNBUL

64 1 Semi-Continuous 120-277 50/60 KPCF64S3G4NBUL KPCF64S3J5NBUL KPCF64S3RNBUL

Wall 64 3/4 Semi-Continuous 120-277 50/60 KPWF64S2G4NBUL KPWF64S2J5NBUL KPWF64S2RNBUL

64 1 Semi-Continuous 120-277 50/60 KPWF64S3G4NBUL KPWF64S3J5NBUL KPWF64S3RNBUL

90° Stanchion 64 1-1/4 Semi-Continuous 120-277 50/60 KPRF64S4G4NBUL KPRF64S4J5NBUL KPRF64S4RNBUL

64 1-1/2 Semi-Continuous 120-277 50/60 KPRF64S5G4NBUL KPRF64S5J5NBUL KPRF64S5RNBUL

25° Stanchion 64 1-1/4 Semi-Continuous 120-277 50/60 KPSF64S4G4NBUL KPSF64S4J5NBUL KPSF64S4RNBUL

64 1-1/2 Semi-Continuous 120-277 50/60 KPSF64S5G4NBUL KPSF64S5J5NBUL KPSF64S5RNBUL

NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.

1190 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Catalog Numbers
Lamp Hub Size Mode of with Type V 12” Refractor with Enclosed
Watts (Inches) Operation Volts Hz with Globe ➊➋ ➊➋➌ Reflector ➊➋➌
Pendant ➍ 84 3/4 Semi-Continuous 120-277 50/60 KPAF84S2G4NBUL KPAF84S2J5NBUL KPAF84S2RNBUL

Lighting
84 1 Semi-Continuous 120-277 50/60 KPAF84S3G4NBUL KPAF84S3J5NBUL KPAF84S3RNBUL

Lighting: Enclosed and Gasketed — Emergency


Pendant Cone 84 3/4 Semi-Continuous 120-277 50/60 KPDF84S2G4NBUL KPDF84S2J5NBUL KPDF84S2RNBUL

84 1 Semi-Continuous 120-277 50/60 KPDF84S3G4NBUL KPDF84S3J5NBUL KPDF84S3RNBUL

Ceiling 84 3/4 Semi-Continuous 120-277 50/60 KPCF84S2G4NBUL KPCF84S2J5NBUL KPCF84S2RNBUL

84 1 Semi-Continuous 120-277 50/60 KPCF84S3G4NBUL KPCF84S3J5NBUL KPCF84S3RNBUL

Wall 84 3/4 Semi-Continuous 120-277 50/60 KPWF84S2G4NBUL KPWF84S2J5NBUL KPWF84S2RNBUL

84 1 Semi-Continuous 120-277 50/60 KPWF84S3G4NBUL KPWF84S3J5NBUL KPWF84S3RNBUL

90° Stanchion 84 1-1/4 Semi-Continuous 120-277 50/60 KPRF84S4G4NBUL KPRF84S4J5NBUL KPRF84S4RNBUL

84 1-1/2 Semi-Continuous 120-277 50/60 KPRF84S5G4NBUL KPRF84S5J5NBUL KPRF84S5RNBUL

25° Stanchion 84 1-1/4 Semi-Continuous 120-277 50/60 KPSF84S4G4NBUL KPSF84S4J5NBUL KPSF84S4RNBUL

84 1-1/2 Semi-Continuous 120-277 50/60 KPSF84S5G4NBUL KPSF84S5J5NBUL KPSF84S5RNBUL

NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1191


© September 2010
Mercmaster™ III Emergency Battery Pack Mounting Hoods and Ballast Bodies
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Mounting Hoods
Description Hub Size (Inches) Catalog Number
Pendant
Lighting

3/4 KPA-75
One Hub, Rigid Mounting
1 KPA-100
3/4 KPAF-75
One Hub, Flexible Mounting
1 KPAF-100
Pendant Cone
Lighting: Enclosed and Gasketed — Emergency

One Hub, 3/4 KPCH-75


Rigid Mounting 1 KPCH-100

Ceiling

Five Hubs, 3/4 KPC-75


Four Close-Up Plugs 1 KPC-100

Wall

Five Hubs, 3/4 KPWB-75


Four Close-Up Plugs 1 KPWB-100

25° Stanchion
One Hub 1-1/4 KPS-125
1-1/2 KPS-150

90° Stanchion
One Hub 1-1/4 KPST-125
1-1/2 KPST-150

Ballast Bodies
Lamp Ballast Body
Wattage Mode of Operation Voltage Hz Catalog Number
26 Continuous 120-277 50/60 KPBC26FBU
26 Emergency 120-277 50/60 KPBE26FBU
26 Semi Continuous 120-277 50/60 KPBS26FBU
52 Continuous 120-277 50/60 KPBC52FBU
52 Emergency 120-277 50/60 KPBE52FBU
52 Semi Continuous 120-277 50/60 KPBS52FBU
64 Semi-Continuous 120-277 50/60 KPBS64FBU
84 Semi-Continuous 120-277 50/60 KPBS84FBU

1192 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Emergency Battery Pack Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations

Simultaneous Exposure Wet Locations


Class I, Division 2, Class II, Division 1 NEMA 4X
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Item Description Catalog Number


White Polyester Reflectors
For use with globe fixtures

Lighting
Standard Dome CMR4-ST *

17 117
.06 4337.0.066" 30° Angle CMR4-AN
18.70" 18.70"
18.70"/ " .3 "/
475.0 mm mm
Standard Dome17.
06
18.70" " 17
.06 30° Angle
7-11/16"
18.70" 7-11/16"
"
Prismatic Glass Globes
7.69" /195.3 mm

Lighting: Enclosed and Gasketed — Emergency


7-11/16"
11-5/16"11-5/16"
7-11/16" Heat-resistant Clear VPGL-4HR

11-5/16"
11.31”11-5/16"
/287.3 mm
6-1/4" 6-1/4"

6-1/4"
6.25” /158.8 mm 7.69"
6-1/4" 7.69"

Closed Prismatic Glass


7.69" Refractors
7.69" mm
7.69”/195.3
11.50" 11.50"
11.50" NEMA Type II KPRF400-2
11.50"
11.58”/294.1 mm
NEMA Type V KPRF400-5
12.05" 12.05"
12.05”/306.1
12.05" mm
12.05"
Enclosed Reflector Assembly
7.69" 7.69"
7.69"
7.69”/195.3
7.69" mm
Heat- and impact-resistant glass lens KPR-4HB

11.50" 11.50" 11.50"


11.50”/292.1
11.50" mm

16.38" 16.38"
16.38"
16.38"
16.38”/ 416.1mm

Stainless Steel Guards


Globe Guard KPGU400
Refractor Guard KPBG12
Enclosed Reflector Guard GHB7000-NG

Globe Refractor

Enclosed Reflector
Photocontrol
Factory-Installed † Voltage Range Suffix Designation
120 V, 50/60 Hz H1
208 V, 50/60 Hz H2
Mercmaster III Wall Mounting with 240 V, 50/60 Hz H3
Photocontrol Factory Installed 277 V, 50/60 Hz H4
Field-Installed Max. Current Voltage Range Catalog Number
8.3 A 120 V, 50/60 Hz PC120D2
3.5 A 208-277 V, 50/60 Hz PC247D2
Photocontrol for Field Installation
* Consult factory if used with KPWB or KPST mounting hoods.
† Add to fixture catalog after voltage; i.e.: KPWF26C2G4NBULH1.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1193


© September 2010
Mercmaster™ III Emergency Battery Pack Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations

Item Description Catalog Number


Three-Way Exit Sign

Epoxy enameled steel — 10” high red lettering EXR400


Lighting

Mounts to fixture units in place of guard

Replacement Optic Gaskets


Silicone Rubber

Globe, Refractor and KRF-GK


Lighting: Enclosed and Gasketed — Emergency

Enclosed Refractor Gasket

Replacement Lamp

Lamp Type Lamp Base Wattage Catalog Number


PL-C G24Q-1 13 PLC134
PL-T G24q-4 26 PLT26
PL-T G24q-4 32 PLT32

PLC PLT PL-T G24q-4 42 PLT42

Replacement Socket
For 26 W (2 x 13 W) PLC Lamps PLC13RS
For 26 W, 32 W and 42 W PLT Lamps listed above PLT32RS

PLC PLT

Retrofit Pendant Mounting Adapter


Permits use of Mercmaster III pendant hood with 3/4” hub on existing
LPAD-1
V-51 mounting hood.

Fuse Kit
2-amp time delay fuse F2

1194 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
EFDB™ Factory Sealed Push-To-Test Station
Explosionproof, Dust-Ignitionproof

Applications Hub Size Catalog Number


• Push-to-test switch permits (Inches) Description Dead-End Feed-Thru
interruption of AC power to fixture to
provide verification in an emergency Single Gang *
lighting system that battery packs and

Lighting
lamps are functioning properly. Momentary Contact
Features 1/2 EFDB150-U1-TEST EFDCB150-U1-TEST
1 Circuit
• Eliminates need for adding sealing 3/4 EFDB175-U1-TEST EFDCB175-U1-TEST
fittings and compound at each conduit Universal
entrance (Groups C and D). 1 EFDB110-U1-TEST EFDCB110-U1-TEST
• Heavy-duty, 10 ampere 600 V rated. Replacement Parts for Push-to-Test Switch
• Smooth, rounded integral bushing in

Lighting: Enclosed and Gasketed — Emergency


each EFDB hub protects conductor Description Catalog Number
insulation.
• Accurately tapped, tapered hubs for Complete Cover Assy EFKB-U1-TEST
tight, rigid joints and ground continuity.
Push Button Only SPBBU1Q
• Stainless steel push button shaft
operators within stainless steel bushing Test Legend Plate SNPTESTQ
assures long, maintenance-free
operation.
• Push button contacts are silver
cadmium oxide which are “sealed”
in lower phenolic chamber isolated
from corrosive elements. Assures
positive contact and long, trouble-free
operation.
• Enclosed stainless steel helper spring
prevents accidental operation of push
button in severe vibration installations.
• Corrosion-resistant captive stainless
steel hex-head cap screws hold EFKB
cover to body. 12-24 x 1 (4) Screws
• All EFDB front-operated push buttons
are supplied with lockout type guards
as standard. Hole in guard will accept
locks with up to 1/4” hasp. Permits
locking of push button to prevent
unauthorized operation.
• Clearly marked terminals with brass A 5.41”/
4.63”/ 137.4 mm
screws assure quick, easy wiring. 117.6 mm 6.38”/
B
162.1 mm

9/32 Dia.
Hole

2.31"/ 5/16 Dia.


58.7 mm
3.00”/ (2) Mtg. C
76.2 mm Holes 5.00”/
127 mm

EFDB Single Gang Push-To-Test Control Station

Hub Size Dimensions in Inches/Millimeters


(Inches) A B C
1/2 & 3/4 5.38/136.7 6.13/155.7 0.78/19.8
1 5.50/139.7 6.31/160.3 0.94/23.9
* Malleable iron body and aluminum cover. For aluminum body, add suffix -A.
For Class I, Group B, external seals must be installed at each conduit entrance.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1195


© September 2010
Mercmaster™ III Emergency Battery Pack Dimensions and Weights
Enclosed and Gasketed. For Hazardous and Wet Locations

Ceiling with Refractor


Pendant with Globe, Guard and Reflectors 90° Stanchion
Enclosed Reflector and Guards

13.44"/ 13.44"/
341.4 mm 341.4 mm
Lighting

17.23"/
437.6 mm
11.21"/
284.7 mm
9.79"/
11.0"/ 248.6 mm
279.4 mm 11.82"/
300.2 mm

12.09"/
Lighting: Enclosed and Gasketed — Emergency

6.04" / 307.1 mm
153.4 mm 10.38"/
10.25"/ 11.65"/ 263.7 mm
260.4 mm 295.9 mm 10.35"/
10.77"/ --1
7.0
262.9 mm 11.44"/
273.6 mm 6"
/4 12.38"/ 290.6 mm
33
.3
mm 314.5 mm
Dia
.
12.12"/
307.8 mm
18.70"/ 475.0 mm Dia.
16.38"/
8.80"/ 12.25"/ 416.1 mm
223.5 mm 311.2 mm Dia.

25° Stanchion Wall Cone


0.31"/ 17.00"/
/ 431.8 mm
27" m
7.9 mm Dia
15. .9 m 13.44"/
7 341.4 mm
103.1 mm

3 8
4.06"/

5"/
9.2.0 mm "/
8
235 8.1 mm
7 "/
m

.7 1.38"/
207
0. 75
m
12 4.

35.1 mm
/ 13.08"/
07" m 332.2 mm
12. .8 m
30 6
15.63"/
422.4 mm

12.12"/
307.8 mm

Mercmaster III – Emergency Ballast and Accessory Weights *

Ballast Housing (Wt. lbs/kg)


Semi- Refractor, Globe,
Lamp Watts Continuous Continuous Emergency Mounting Hoods Wt. (lbs/kg) Reflector and Guards Wt. (lbs/kg)
26 23.00/10.4 23.00/10.4 23.00/10.4 Pendant 2.25/1.0 Standard Dome 3.50/1.6
Pendant Cone 2.50/1.1 30° Angle 3.50/1.6
52 23.00/10.4 23.00/10.4 23.00/10.4 Ceiling 3.00/1.4 Glass Globe 7.00/3.2
Wall 4.00/1.8 Globe Guard 3.00/1.4
64 — 23.00/10.4 — 25° Stanchion 3.25/1.5 12” Glass Refractor 12.00/5.4
90° Stanchion 3.75/1.7 Refractor Guard 4.50/2.0
84 — 23.00/10.4 — Enclosed Reflector 11.00/5.0
Enclosed Reflector Guard 2.00/0.9

* Weights are approximate.

1196 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Emergency Battery Pack Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations

Total Luminaire Efficiency = 58.3%


CIE Type – Semi-Direct REPORT NUMBER: KPBF26BU_G
Spacing 26 W (two 13 W PLT lamps) Fluorescent Fixture with Globe only
Plane Criteria

Lighting
0-180 2.98 Coefficients of Utilization - Zonal Cavity Method
90-270 2.98 Effective Floor Cavity Reflectance 0.20
Diagonal 2.94 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 64 64 64 64 60 60 60 60 52 52 52 45 45 45 39 39 39 36
0-10 4.21 1 55 51 47 44 51 47 44 41 40 38 35 34 32 30 29 27 25 23
10-20 14.03 2 48 42 37 33 45 39 34 31 33 30 26 28 25 22 23 21 19 16

Lighting: Enclosed and Gasketed — Emergency


20-30 29.45 3 43 36 30 26 40 33 28 24 28 24 21 24 20 17 19 17 14 12
30-40 52.29 4 39 31 25 21 36 29 23 19 24 20 17 20 17 14 16 14 11 9
40-50 76.42 5 36 27 21 17 33 25 20 16 21 17 14 18 14 11 14 12 9 7
50-60 97.89 6 33 24 18 14 30 22 17 13 19 15 11 16 12 10 13 10 8 6
60-70 115.41 7 30 21 16 12 27 20 15 11 17 13 10 14 11 8 12 9 7 5
70-80 126.24 8 28 19 14 10 25 18 13 10 15 11 8 13 9 7 10 8 6 4
80-90 130.30 9 26 17 12 9 24 16 12 8 14 10 7 12 8 6 10 7 5 4
90-100 128.10 10 24 16 11 8 22 15 10 7 13 9 6 11 8 5 9 6 4 3
100-110 116.00
110-120 87.78 Zonal Lumen Summary
120-130 49.16 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 17.40 0-30 47.69 2.6 4.5 90-120 331.87 18.4 31.6
140-150 3.58 0-40 99.98 5.6 9.5 90-130 381.04 21.2 36.3
150-160 0.35 0-60 274.29 15.2 26.2 90-150 402.02 22.3 36.3
160-170 0.02 0-90 646.24 35.9 61.6 90-180 402.40 22.4 38.4
170-180 0.00 0-180 1048.64 58.3 100.0

Total Luminaire Efficiency = 77.4%


CIE Type – Direct REPORT NUMBER: KPBF26BU_ST
Spacing 26 W (two 13 W PLT lamps) Fluorescent Fixture with Globe and Reflector
Plane Criteria
0-180 1.68 Coefficients of Utilization - Zonal Cavity Method
90-270 1.68 Effective Floor Cavity Reflectance 0.20
Diagonal 1.82 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 92 92 92 92 90 90 90 90 86 86 86 82 82 82 79 79 79 77
0-10 27.68 1 83 78 74 71 81 77 73 70 73 70 68 70 68 65 67 65 63 62
10-20 83.17 2 74 67 60 55 72 65 59 55 62 57 53 59 55 52 57 54 51 49
20-30 138.57 3 66 57 50 44 64 56 49 44 53 48 43 51 46 42 49 45 41 39
30-40 194.85 4 60 50 42 36 58 49 41 36 46 40 35 45 39 35 43 38 34 32
40-50 240.48 5 55 44 36 30 53 43 35 30 41 34 30 39 34 29 38 33 29 27
50-60 264.71 6 50 39 31 26 49 38 31 25 36 30 25 35 29 25 34 29 25 23
60-70 251.68 7 46 35 27 22 45 34 27 22 33 26 22 32 26 22 31 25 21 20
70-80 154.88 8 43 31 24 19 41 31 24 19 30 24 19 29 23 19 28 23 19 17
80-90 37.26 9 40 29 22 17 39 28 22 17 27 21 17 26 21 17 25 20 17 15
90-100 0.55 10 37 26 20 15 36 26 19 15 25 19 15 24 19 15 23 19 15 13
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 249.42 13.9 17.9 90-120 0.55 0.0 0.1
140-150 0.00 0-40 444.27 24.7 31.9 90-130 0.55 0.0 0.1
150-160 0.00 0-60 949.47 52.7 68.1 90-150 0.55 0.0 0.1
160-170 0.00 0-90 1393.29 77.4 100.0 90-180 0.55 0.0 0.1
170-180 0.00 0-180 1393.83 77.4 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1197


© September 2010
Mercmaster™ III Emergency Battery Pack Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations

Total Luminaire Efficiency = 90.2%


CIE Type – Semi-Direct REPORT NUMBER: KPBF84BU_G
Spacing 84 W (two 42 W PLT lamps) Fluorescent Fixture with Globe Only
Plane Criteria
Lighting

0-180 2.72 Coefficients of Utilization - Zonal Cavity Method


90-270 2.72 Effective Floor Cavity Reflectance 0.20
Diagonal 2.72 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 99 99 99 99 93 93 93 93 81 81 81 70 70 70 60 60 60 55
0-10 23.61 1 85 78 73 68 79 73 68 63 62 58 55 53 50 47 44 42 39 35
10-20 79.09 2 75 65 57 51 69 61 53 47 52 46 41 43 39 35 35 32 29 25
Lighting: Enclosed and Gasketed — Emergency

20-30 165.61 3 67 56 47 40 62 52 44 37 44 37 32 36 31 27 30 26 22 18
30-40 289.36 4 61 48 39 32 56 45 36 30 38 31 26 31 26 22 25 21 18 14
40-50 418.89 5 55 42 33 26 51 39 31 25 33 26 21 28 22 18 22 18 14 11
50-60 535.78 6 50 37 29 22 46 35 27 21 29 23 18 24 19 15 20 15 12 9
60-70 628.00 7 46 33 25 19 43 31 23 18 26 20 15 22 17 13 18 14 10 8
70-80 682.79 8 43 30 22 16 39 28 20 15 24 17 13 20 15 11 16 12 9 7
80-90 696.63 9 40 27 19 14 37 25 18 13 22 16 11 18 13 9 15 11 8 6
90-100 676.63 10 37 25 17 12 34 23 16 12 20 14 10 17 12 8 14 10 7 5
100-110 612.00
110-120 481.82 Zonal Lumen Summary
120-130 304.45 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 133.76 0-30 268.3 4.2 4.6 90-120 1770.44 27.7 30.7
140-150 39.22 0-40 557.66 8.7 9.7 90-130 2074.89 32.4 35.9
150-160 5.66 0-60 1512.33 23.6 26.2 90-150 2247.86 35.1 35.9
160-170 0.24 0-90 3519.72 55.0 61.0 90-180 2253.77 35.2 39.0
170-180 0.00 0-180 5773.48 90.2 100.0

Total Luminaire Efficiency = 72.8%


CIE Type – Direct REPORT NUMBER: KPBF84BU_ST
Spacing 84 W (two 42 W PLT lamps) Fluorescent Fixture with Globe and Reflector
Plane Criteria
0-180 1.66 Coefficients of Utilization - Zonal Cavity Method
90-270 1.66 Effective Floor Cavity Reflectance 0.20
Diagonal 1.80 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 87 87 87 87 85 85 85 85 81 81 81 77 77 77 74 74 74 73
0-10 88.11 1 77 73 69 65 75 71 67 64 68 65 62 65 62 60 62 60 58 57
10-20 264.99 2 69 61 55 50 67 60 55 50 57 53 49 55 51 47 52 49 46 45
20-30 444.26 3 62 53 46 40 60 51 45 40 49 44 39 47 42 38 45 41 37 36
30-40 624.25 4 56 46 38 33 54 45 38 32 43 37 32 41 36 31 39 35 31 29
40-50 769.77 5 51 40 33 27 49 39 32 27 38 31 27 36 31 26 35 30 26 24
50-60 853.68 6 47 36 28 23 45 35 28 23 34 27 23 32 27 23 31 26 22 21
60-70 821.26 7 43 32 25 20 42 31 25 20 30 24 20 29 24 20 28 23 19 18
70-80 573.91 8 40 29 22 17 38 28 22 17 27 21 17 26 21 17 25 21 17 15
80-90 212.45 9 37 26 20 15 36 26 20 15 25 19 15 24 19 15 23 19 15 14
90-100 4.66 10 35 24 18 14 34 24 18 14 23 17 14 22 17 14 22 17 14 12
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 797.37 12.5 17.1 90-120 4.66 0.1 0.1
140-150 0.00 0-40 1421.62 22.2 30.5 90-130 4.66 0.1 0.1
150-160 0.00 0-60 3045.07 47.6 65.4 90-150 4.66 0.1 0.1
160-170 0.00 0-90 4652.69 72.7 99.9 90-180 4.66 0.1 0.1
170-180 0.00 0-180 4657.35 72.8 100.0

1198 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mercmaster™ III Emergency Battery Pack Lumen Curves
Enclosed and Gasketed. For Hazardous and Wet Locations

BHD65U Lumen Curve


BHD65U Lumen Curve
One Lamp PL-T 42 W In Emergency Mode
One Lamp PL-T 32 W In Emergency Mode
400
300

350

Lighting
250
300

200 250

Lumens
Lumens

200
150

150

Lighting: Enclosed and Gasketed — Emergency


100
100

50 50

0
0 0 10 20 30 40 50 60 70 80 90
0 10 20 30 40 50 60 70 80 90
Discharge time (minutes)
Discharge time (minutes)

BHD65U Lumen Curve


Two Lamp PL-T 26 W In Emergency Mode
450

400

350

300
Lumens

250

200

150

100

50

0
0 10 20 30 40 50 60 70 80 90
Discharge time (minutes)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1199


© September 2010
N2LS™ Series Emergency Luminaires
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Class I, Division 2, Groups B, C, D


Class I, Zone 2, Group IIB + H2
NEMA 3R

Applications
• Enclosed and gasketed, non-metallic emergency lighting
system suitable for use in areas where flammable gases or
vapors may become present due to abnormal, unusual or
accidental conditions defined by NEC as Class I, Division 2,
Lighting

Groups B, C and D and Class I, Zone 2, Group II B + H2.


• Typical applications include manufacturing plants, refineries,
petrochemical and chemical plants, waste and sewerage
treatment facilities, food processing facilities, and other
industrial manufacturing or process facilities subject to wet or
corrosive conditions.
• Non-hazardous areas where dirt, dust or corrosion would
reduce life of ordinary emergency lighting systems.
Lighting: Enclosed and Gasketed — Emergency

Features
• Certified for use in Class I, Division 2, Groups B, C, D; Class I,
Zone 2, Group II B + H2 Hazardous Locations.
• Enclosures are Type 3R (raintight) rated and suited for operation
in highly corrosive and wet locations.
• The electronics consist of a solid-state charger, transfer circuit
and low voltage battery disconnect circuit.
• The test switch and AC “On” indicator light are mounted on the
system housing utilizing a neoprene “O-ring” gasket to seal out
moisture and liquids.
• Capacity is sufficient for the connection of 36 or 72 output
Watts (maximum). Standard Materials
• Housing provisions allow for the attachment of single or dual, 8
or 12 Watt halogen sealed beam heads (Wattage cannot exceed • Lighting system:
unit capacity.) —Body: Compression molded, fiberglass reinforced polyester
• Provides 90 minutes of emergency operation. (FRP)
• The solid-state charger maintains battery at full charge. — Gasket: continuous silicone gasket and FRP
• Upon failure or 35% dip of utility voltage (AC), the DC — Mounting feet: fiberglass reinforced polyester
emergency lighting load is connected to the battery. • Remote unit:
• During emergency operation, automatic battery protection from — Body: specially formulated fiberglass reinforced polyester
deep discharge damage is provided by a low-voltage battery with low surface resistivity that will not hold a static charge
disconnect (LVD) circuit. — Mounting feet: stainless steel
• Upon restoration of normal power, the charger will begin a — Screws (hold covers to bodies): stainless steel
recharge cycle. It will bring the battery to full capacity within — Gasket (between covers to bodies): neoprene
acceptable UL time standards. • Gaskets (under pilot light and push to test switch): neoprene
• A pilot light indicates the presence of AC line voltage, and a test • Hubs: glass filled polyester with zinc plated steel insert
switch is provided for checking transfer operation. • Lamphead: Noryl® thermoplastic
• A universal transformer allows operation on 120, 220, 240 or Certifications and Compliances
277 VAC 50/60HZ. lines. • UL Standard: UL 924
• Emergency power source is a sealed cell, lead acid, • UL Listed: E175025
maintenance-free battery suited for harsh temperature • NFPA 101 Life Safety Code
environments of 32° to 104°F / 0° to 40°C.
• 15 amp fuse provided as standard.
• Expected life is 10 years.
• Remote lamp head assemblies (one or two) are available for
mounting of lamp heads away from main power supply system.
• Time delay relay (15 min.) provided as standard; allows time for
HID lighting to reach desired illumination levels.

1200 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
N2LS™ Series Emergency Luminaire Technical Data
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Class I, Division 2, Groups B, C, D


Class I, Zone 2, Group IIB + H2
NEMA 3R

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For N2LS
N2LS 2 8 36 6

Lighting
Series: Wattage Per Lamp Lamp Voltage:
N2LS - Emergency Lighting System 8-8W 6 - 6 Vdc
12 - 12 W 12 - 12 Vdc
N - No Direct Mounted Fixture
Number of Direct Mount Lamps: Wattage Capacity:
0 - None 36 - 36 W
1 - One 72 - 72 W

Lighting: Enclosed and Gasketed — Emergency


2 - Two

Thermal Performance — Operating Temperatures


Wire Supply Ambient Temperature “T” Number
140°F/60°C Min. 32°F to max 104°F / 0°C to max 40°C T6

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(˚ºF)
Temp
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(ºC)

Wire Sizing For Remote Installations


For copper wire, maximum distance (feet) between power supply and remote unit to limit voltage drop to 5%.
For 6 Volt Units - Load in Watts For 12 Volt Units - Load in Watts
Wire Size 8 16 24 32 8 16 24 32
16 AWG 26 13 6 3 52 26 12 6
14 AWG 42 21 10 5 84 42 20 10
12 AWG 66 33 16 8 132 66 32 16
10 AWG 106 53 26 13 212 106 52 26
8 AWG 168 84 42 21 336 168 84 42
6 AWG 270 135 67 33 540 270 134 66

Capacity of Standard N2LS Units


Up to two lamps may be direct mounted. The remainder must be remote mounted.
Number of lamps accommodated is dependent on whether 36 or 72 Watt unit is used.

Combination Number 1 2 3 4 6 7 8 9 10 11 12 13 14 15

Number of Lamps 1 1 2 2 3 3 4 4 5 5 6 7 8 9

Watts per Lamp 8 12 8 12 8 12 8 12 8 12 12 8 8 8

Total Wattage 8 12 16 24 24 36 32 48 40 60 72 56 64 72

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1201


© September 2010
N2LS™ Series Emergency Luminaires
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Class I, Division 2, Groups B, C, D


Class I, Zone 2, Group IIB + H2
NEMA 3R

Number Watts Lamp Wattage Hub Input Weight Catalog


Frequency
of Lamps Per Lamp Voltage (DC) Capacity Size Voltage * lbs/kg Number
Emergency Lighting System With Two Direct Mount Lamps
2 8 6 36 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS28366
Lighting

2 8 12 36 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS283612


2 8 6 72 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS28726
2 8 12 72 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS287212
2 12 6 36 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS212366
2 12 12 36 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS2123612
2 12 6 72 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS212726
Lighting: Enclosed and Gasketed — Emergency

2 12 12 72 3/4” 120-277 50/60 Hz 19.50/8.8 N2LS2127212


Emergency Lighting System With One Direct Mount Lamp
1 8 6 36 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS18366
1 8 12 36 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS183612
1 8 6 72 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS18726
1 8 12 72 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS187212
1 12 6 36 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS112366
1 12 12 36 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS1123612
1 12 6 72 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS112726
1 12 12 72 3/4” 120-277 50/60 Hz 18.50/8.4 N2LS1127212
Emergency Lighting System Without Direct Mount Lamps
— — 6 36 3/4” 120-277 50/60 Hz 17.50/7.9 N2LS0N366
— — 12 36 3/4” 120-277 50/60 Hz 17.50/7.9 N2LS0N3612
— — 6 72 3/4” 120-277 50/60 Hz 17.50/7.9 N2LS0N726
— — 12 72 3/4” 120-277 50/60 Hz 17.50/7.9 N2LS0N7212

Number Watts Lamp Hub Hub Weight Catalog


of Lamps Per Lamp Voltage (DC) Size Position * lbs/kg Number
Remote Mount With One Lamp
1 8 6 3/4” Dead End Hub on Right 4.00/1.8 N2RR186
1 8 12 3/4” Dead End Hub on Right 4.00/1.8 N2RR1812
1 12 6 3/4” Dead End Hub on Right 4.00/1.8 N2RR1126
1 12 12 3/4” Dead End Hub on Right 4.00/1.8 N2RR11212

Remote Mount With Two Lamps


2 8 6 3/4” Dead End Hub on Right 5.00/2.3 N2RR286
2 8 12 3/4” Dead End Hub on Right 5.00/2.3 N2RR2812
2 12 6 3/4” Dead End Hub on Right 5.00/2.3 N2RR2126
2 12 12 3/4” Dead End Hub on Right 5.00/2.3 N2RR21212

* Input voltage is 120, 220, 240 and 277

1202 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
N2LS™ Series Emergency Luminaire Dimensions
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Dimensions (In/mm)

Direct Mount Fixture Single Remote Mount Fixture Dual Remote Mount Fixture

1.75"/

Lighting
44.5 mm

1.00"/
25.4 mm 1.00"/
25.4 mm

103.1 mm
103.1 mm

71.4 mm
71.4 mm

88.9 mm
88.9 mm

2.81"/
4.06"/
2.81"/
4.06"/

3.50"/
1.62"/ 1.62"/

3.50"/
18.61"/ 41.1 mm 41.1 mm
472.7 mm .31” dia.
12.50"/ (4) mtg holes
317.5 mm

Lighting: Enclosed and Gasketed — Emergency


.31"/ .31"/
7.9 mm Dia. 7.9 mm Dia. 12.13"/ 308.1 mm
(4) mtg holes 7.56"/ 192.0 mm
(4) mtg holes 12.44"/ 316.0 mm
8.16"/ 207.7 mm
.31"/ 13.25"/ 336.6 mm
7.9 mm Dia. 8.78"/ 223.0 mm
11.63"/296.9 mm 14.13"/ 385.9 mm
(4) mtg holes 9.56"/ 242.8 mm
14.80"/375.9 mm

5.44”/ 5.44”/
138.2 mm 138.2 mm

1.44”/
35.6 mm

9.63”/ 9.63”/
244.6 mm 244.6 mm

6.88”/
174.8 mm
1.38"/ 1.38"/
35.1 mm 35.1 mm

4.65"/ 4.65"/
118.1 mm 118.1 mm
Adjustment Angle Data For Remote Unit

100º
55º

26º

Top View Side View

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1203


© September 2010
N2LS™ Series Emergency Luminaire Photometric Data
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Photometric Data

Horizontal Isofootcandle Distribution Curves for 8 Watts Vertical Isofootcandle Distribution Curves for 8 Watts
Lighting

20
20
20
20
Feet
Feet
Feet
Feet Left
Left
Left
Left
10
10
10
10

Lamp 1 0.5 0.3 0.2 0.1


Lamp 1 0.5 0.3 0.2 0.1 00 Axis
00 Axis
Lighting: Enclosed and Gasketed — Emergency

10
10
10
10
Feet
Feet
Feet
Feet
Right
Right
Right
Right
20
20
20
20
00 10 20 30 40 50 60 70 80 00 10
10 20
20 30
30 40
40 50
50 60
60 70
70 80
80
10 20 30 40 50 60 70 80 FEET FROM LAMP ( MEASURED ON AXIS )
FEET FROM LAMP ( MEASURED ON AXIS ) FEET FROM LAMP (MEASURED ON AXIS)
FEET FROM LAMP (MEASURED ON AXIS)

Horizontal Isofootcandle Distribution Curves for 12 Watts Vertical Isofootcandle Distribution Curves for 12 Watts
20
20 20
20
Feet
Feet Feet
Feet
Left Left
Left Left
10
10 10
10

1 0.5 0.3 0.2 0.1 1 0.5 0.3 0.2 0.1


00 0

10
10 10
10
Feet
Feet Feet
Feet
Left
Left Left
Left
20
20 20
20
00 20
20 40
40 60
60 80
80 100
100 00 20
20 40
40 60
60 80
80 100
100
FEET
FEETFROM
FROMLAMP
LAMP( MEASURED
(MEASUREDON
ONAXIS
AXIS)) FEET FROM LAMP ( MEASURED ON AXIS )
FEET FROM LAMP (MEASURED ON AXIS)

1204 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

NEC: CSA: V
Class I, Division 1 and 2, Groups B, C, D Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G Class II, Division 1 and 2, Groups E, F, G
Class III Class III
Marine type electric fixtures, outside type Type 4X
(salt water) Exd IIB + H2

Applications
• For use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries;
and in other areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
• Suitable for outdoor saltwater locations and for other
wet locations.
Features
• Fixtures operate safely in high ambient temperatures.
• Arrangement of heat-producing components results in
efficient heat dissipation for cooler fixture operation.
• Patented “wireless” design. Threading of fixture unit
onto mounting hood makes electrical connection. Only
wiring required is attaching two wires to connection block
in mounting hood.

Lighting
• Connection block is easily wired: (a) loosen two screws, (b)
make wire connections, and (c) re-position connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
• Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or

Lighting: Explosionproof — Area — HID


gall, eliminating problems often encountered with single-lead
threads during fixture unit removal.
• All threaded joints are flame-tight.
• Integrally ballasted HID lighting fixtures; separate ballasts
not required.
• Factory sealed. External seals not required for Groups C and D.
• Fixtures for use in NEC Group B locations furnished complete
with UL required sealing fitting. Not required for CEC approval.
• Strategic location of lamp socket, in combination with interior Standard Materials
prism design of the glass globe, provides optimum light • Ballast bodies and guards: copperfree (4/10 of 1% max.)
distribution and control. aluminum
• Heat and impact-resistant globes have smooth • Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
dust-resistant exterior. aluminum
• Superior corrosion resistance, with epoxy powder coat finish. • Ceiling, bracket and stanchion mounting hoods: sand cast
• Shock-absorbing medium-base socket mounts prolong copperfree (4/10 of 1% max.) aluminum
lamp life. • Reflectors: fiberglass reinforced polyester
• Porcelain socket with nickel-plated phosphor bronze
screw shell. Standard Finishes
Assures long trouble-free operation in high ambient areas. • Ballast bodies, guards and mounting hoods: epoxy powder
• Choice of mountings: pendant, ceiling, bracket and stanchion. coat finish, electrostatically applied for complete, uniform
• Fiberglass-reinforced polyester reflectors, in standard dome, corrosion protection
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres.
Options
• Optional guards protect globes from damage. Secured to • Fuses: order fuses for field installation by catalog number, see
fixture with three stainless steel screws. Ballast and Fuse Kit Data.
• Variety of light sources: high pressure sodium, pulse start metal • “Hot Restrike” – add suffix -R. “Smart Starter” – add suffix -S.
halide and metal halide. HPS is excellent where long lamp life Emergency Options available for 50 W through 150 W HPS only.
is required. HPS provides high lumens per watt and is less • For CEC Exd IIB + H2 rating, add suffix -Z V.
expensive to operate. PSMH and MH are desirable where • For safety chain, add suffix -SC.
colors in illuminated areas must be close to natural. Certifications and Compliances
• A wide range of ballasts and voltages are available for both
• UL Standard: UL 1598, UL 844
domestic and export applications.
• UL Listed: E10444
• Ballasts operate at low temperatures – PSMH/MH: -20 °F/-29 °C;
• CSA Standard: C22.2 No. 250, C22. 2No. 137
HPS: -40 °F/-40 °C.
• CSA Certified: 025428
• 50 W through 150 W high pressure sodium ballasts are high
reactance, high power factor type. Related Products
• For sealing fittings, see the Fittings Section.

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1205


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

NEC: CSA: V
Class I, Division 1 and 2, Groups B, C, D Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G Class II, Division 1 and 2, Groups E, F, G
Class III Class III
Marine type electric fixtures, outside type Type 4X
(salt water) Exd IIB + H2

104 °F/40˚ °C ➊ 131 °F/55 ˚°C ➊ 149 °F/65 °C ➊ 104 °F/40 ˚°C ➋
Ambient Supply Ambient Supply Ambient Supply Ambient Supply
Lamp Ballast Temp. “T” Wire Temp Temp. “T” Wire Temp Temp. “T” Wire Temp Temp. “T” Wire Temp
Watts Type † Numbers °F/°C Numbers °F/°C Numbers °F/°C Numbers °F/°C
High Pressure Sodium — Medium Base Lamps
50 MT, TT T6 167/75 T5 167/75 T4A 167/75 T4 167/75
70 MT, TT, 480 V T5 167/75 T4A 167/75 T4A 167/75 T4 194/90
100 MT, TT, 480 V T4A 167/75 T4 194/90 — T3B 194/90
150 MT, TT, 480 V T3C 167/75 — — —
Pulse Start Metal Halide — Medium Base Lamps
50 MT, TT T6 167/75 T5 167/75 T4A 194/90 T3C 194/90
Lighting

70 MT, TT, 480 V T5 167/75 T4A 167/75 T4A 194/90 T3C 194/90
100 MT, TT, 480 V T4A 194/90 T4A 194/90 —
175 MT, TT, 480 V T3B 194/90 — — —
Metal Halide — Medium Base Lamps V
175 MT, TT, 480 V T3B 185/85 — — —
Lighting: Explosionproof — Area — HID

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(°F)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

Fixture and Accessory Weights lbs/kgs


Fixture Size Fixture Weight Reflector Weight Guard Weight
35 W thru 175 W 28-32/12.70-14.51 3/1.36 1/0.45

Mounting Hood Weights lbs/kgs


Pendant Ceiling Bracket Stanchion
2/.91 4/1.81 6/2.72 2/0.91

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
† MT is Multi-Tap for 120/208/240/277 V, TT is Tri-Tap for 120/277/347 V.
➊ Class I, Division 1 Locations.
➋ Class II, Division 1 Locations.
V CSA Certification only.

1206 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

ANSI Lamp Type ➎ Catalog Number➌ ➋


Type Lamp Hub Size
Mounting Watts HPS PSMH (Inches) HPS➋ ➊ PSMH
Pendant - One Hub, Rigid or Flexible Mounting
50 S68
M110 3/4 CJLPB5075 ➌ CJHPB5075 ➌

70 S62
M98 3/4 CJLPB7075 ➍ CJHPB7075 ➍

100 S54
M90 3/4 CJLPB1075 ➍ CJHPB1075 ➍

150 S55
— 3/4 CJLPB1575 ➍ —

Lighting
175 — M152 3/4 — CJPPB1775 ➍

25˚ Stanchion - One Hub


S68
50 M110 1-1/2 CJLSB50150 ➌ CJHSB50150 ➌

S62

Lighting: Explosionproof — Area — HID


70 M98 1-1/2 CJLSB70150 ➍ CJHSB70150 ➍

S54
100 M90 1-1/2 CJLSB10150 ➍ CJHSB10150 ➍

S55
150 — 1-1/2 CJLSB15150 ➍ —

175 — M152 1-1/2 — CJPSB17150 ➍

Mounting Hoods
Type Hub Size Catalog
Mounting (Inches) Number

Pendant

One Hub 3/4 CAP-75B

25˚ Stanchion

One Hub 1-1/2 CAS-150B

➊ Add suffix -SR (after adding voltage suffix) for “Smart Hot Strike” emergency option, -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G (before adding voltage suffix).
➌ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➍ Add voltage suffix -MT for 120/208/240/277 V, or -48 for 480 V. Contact your sales representative for available 50 Hz ballasts.
➎ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➏ 35 W fixtures have 120 V ballast; add suffix -12

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1207


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

NEC: CSA: V
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G Class II, Division 1 and 2, Groups E, F, G
Class III Class III
Marine type electric fixtures, outside type Type 4X
(salt water) Exd IIB + H2

Lamp ANSI Lamp Type ➏ Hub Size ➐ Catalog Number ➋


Watts HPS PSMH/MH (Inches) HPS ➊ PSMH MH
Pendant — One Hub, Rigid or Flexible Mounting
CJLP5075MT ➌ CJHP5075MT ➌ —
3/4
CJLP5075TTCN V ➌ CJHP5075TTCN V ➌ —
50 S68 M110
CJLP5010MT ➌ CJHP5010MT ➌ —
1
CJLP5010TTCN V ➌ CJHP5010TTCN V ➌ —
CJLP7075MT ➍ CJHP7075MT ➍ —
3/4
CJLP7075TTCN V➎ CJHP7075TTCN V➎ —
70 S62 M98
CJLP7010MT ➍ CJHP7010MT ➍ —
1
CJLP7010TTCN V➎ CJHP7010TTCN V➎ —
CJLP1075MT ➍ CJHP1075MT ➍ —
3/4
CJLP1075TTCN V➎ CJHP1075TTCN V➎ —
100 S54 M90
CJLP1010MT ➍ CJHP1010MT ➍ —
Lighting

1
CJLP1010TTCN V➍ CJHP1010TTCN V➎ —
CJLP1575MT ➍ — —
3/4
CJLP1575TTCN V➎ — —
150 S55 —
CJLP1510MT ➍ — —
1
CJLP1510TTCN V➍ — —
— CJPP1775MT ➍ CJHP1775MTCN V ➍
3/4
Lighting: Explosionproof — Area — HID

— CJPP1775TTCN V➎ CJHP1775TTCN V➎
175 — M152
— CJPP1710MT ➍ CJHP1710MTCN V➍
1
— CJPP1710TTCN V➎ CJHP1710TTCN V➎
Ceiling — Four Hubs, Three Close-Up Plugs
CJLC5075MT ➌ CJHC5075MT ➌ —
3/4
CJLC5075TTCN V➌ CJHC5075TTCN V➌ —
50 S68 M110
CJLC5010MT ➌ CJHC5010MT ➌ —
1
CJLC5010TTCN V➌ CJHC5010TTCN V➌ —
CJLC7075MT ➍ CJHC7075MT ➍ —
3/4
CJLC7075TTCN V➎ CJHC7075TTCN V➎ —
70 S62 M98
CJLC7010MT ➍ CJHC7010MT ➍ —
1
CJLC7010TTCN V➎ CJHC7010TTCN V➎ —
CJLC1075MT ➍ CJHC1075MT ➍ —
3/4
CJLC1075TTCN V➎ CJHC1075TTCN V➎ —
100 S54 M90
CJLC1010MT ➍ CJHC1010MT ➍ —
1
CJLC1010TTCN V➎ CJHC1010TTCN V➎ —
CJLC1575MT ➍ — —
3/4
CJLC1575TTCN V➎ — —
150 S55 —
CJLC1510MT ➍ — —
1
CJLC1510TTCN V➎ — —
— CJPC1775MT ➍ CJHC1775MTCN V➍
3/4
— CJPC1775TTCN V➎ CJHC1775TTCN V➎
175 — M152
— CJPC1710MT ➍ CJHC1710MTCN V➍
1
— CJPC1710TTCN V➎ CJHC1710TTCN V➎

➊ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ For 480 V, contact your sales representative.
➍ Change voltage suffix -MT to -48 for 480 V.
➎ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
➏ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➐ Fixtures with 1” hubs listed for Class I, Group D, and Class II, Groups E, F, G only.
V CSA Certification only.
 Shaded area indicates items suitable for Class I, Division 1, Group B. V

1208 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

NEC: CSA: V
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G Class II, Division 1 and 2, Groups E, F, G
Class III Class III
Marine type electric fixtures, outside type Type 4X
(salt water) Exd IIB + H2

Lamp ANSI Lamp Type ➏ Hub Size ➐ Catalog Number ➋


Watts HPS PSMH/MH (Inches) HPS ➊ PSMH MH
Bracket — Four Hubs, Three Close-Up Plugs
CJLB5075MT ➌ CJHB5075MT ➌ —
3/4
CJLB5075TTCN V➌ CJHB5075TTCN V➌ —
50 S68 M110
CJLB5010MT ➌ CJHB5010MT ➌ —
1
CJLB5010TTCN V➌ CJHB5010TTCN V➌ —
CJLB7075MT ➍ CJHB7075MT ➍ —
3/4
CJLB7075TTCN V➎ CJHB7075TTCN V➎ —
70 S62 M98
CJLB7010MT ➍ CJHB7010MT ➍ —
1
CJLB7010TTCN V➎ CJHB7010TTCN V➎ —
CJLB1075MT ➍ CJHB1075MT ➍ —
3/4
CJLB1075TTCN V➎ CJHB1075TTCN V➎ —
100 S54 M90
CJLB1010MT ➍ CJHB1010MT ➍ —

Lighting
1
CJLB1010TTCN V➎ CJHB1010TTCN V➎ —
CJLB1575MT ➍ — —
3/4
CJLB1575TTCN V➎ — —
150 S55 —
CJLB1510MT ➍ — —
1
CJLB1510TTCN V➎ — —
— CJPB1775MT ➍ CJHB1775MTCN V➍
3/4

Lighting: Explosionproof — Area — HID


— CJPB1775TTCN V➎ CJHB1775TTCN V➎
175 — M152
— CJPB1710MT ➍ CJHB1710MTCN V➍
1
— CJPB1710TTCN V➎ CJHB1710TTCN V➎
25˚ Stanchion — One Hub
1-1/4 or 1-1/2 CJLS50150MT ➌ CJHS50150MT ➌ —
50 S68 M110
➑ CJLS50150TTCN V➌ CJHS50150TTCN V➌ —
1-1/4 or 1-1/2 CJLS70150MT ➍ CJHS70150MT ➌ —
70 S62 M98
➑ CJLS70150TTCN V➍ CJHS70150TTCN V➌ —
1-1/4 or 1-1/2 CJLS10150MT ➍ CJHS10150MT ➌ —
100 S54 M90
➑ CJLS10150TTCN V➍ CJHS10150TTCN V➌ —
1-1/4 or 1-1/2 CJLS15150MT ➍ — —
150 S55 —
➑ CJLS15150TTCN V➍ — —
1-1/4 or 1-1/2 — CJPS17150MT CJHS17150MTCN V
175 — M152
➑ — CJPS17150TTCN V CJHS17150TTCN V

➊ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ For 480 V, contact your sales representative.
➍ Change voltage suffix -MT to -48 for 480 V.
➎ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
➏ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➐ Fixtures with 1” hubs listed for Class I, Group D, and Class II, Groups E, F, G only.
➑ 1-1/2" tapped hub furnished with 1-1/2" to 1-1/4" reducer.
V CSA Certification only.
 Shaded area indicates items suitable for Class I, Division 1, Group B. V

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1209


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

NEC: CSA: V
Class I, Division 1 and 2, Groups B,C, D Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G Class II, Division 1 and 2, Groups E, F, G
Class III Class III
Marine type electric fixtures, outside type Type 4X
(salt water) Exd IIB + H2

Mounting Hoods
Hub Size (Inches) Catalog Number
Pendant — One Hub
3/4 CAP-75
1➋ CAP-100

Ceiling — Four Hubs, Three Close-Up Plugs


3/4 CAC-75
1➋ CAC-100

Bracket — Four Hubs, Three Close-Up Plugs


Lighting

3/4 CALB-75
1➋ CALB-100

25˚ Stanchion — One Hub


1-1/4 or 1-1/2 ➊ CAS-150
Lighting: Explosionproof — Area — HID

Mounting Adapter with Connection Block


Permits use of existing A-51 mounting hoods (AAC Ceiling
or AALB Bracket) with the new Code•Master 2 Fixture Unit.
After removing existing fixture unit and adapter, screw in
the new CMAD-1 Adapter. Then thread new fixture unit into
the CMAD-1. CMAD-1

Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below.

Lamp Fixture Unit Add Voltage Suffixes


Type Watts Number 120/208/240/277 120/277/347 V➍ 480 V
50 CJB50L- MT TTCN —
High Pressure Sodium ➌ 70 CJB70L- MT TTCN 48
High Power Factor
(Min. P.F. 90%) 100 CJB100L- MT TTCN 48
150 CJB150L- MT TTCN 48
50 CJB50H- MT TTCN —
Pulse Start Metal Halide 70 CJB70H- MT TTCN 48
Constant Wattage
(Min. P.F. 90%) 100 CJB100H- MT TTCN 48
175 CJB175P- MT TTCN 48
Metal Halide V
Constant Wattage 175 CJB175H- MT TT C6
(Min. P.F. 90%)

➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.


➋ Mounting Hoods with 1” hub listed for Class I, Group D; Class II, Groups E,F,G; and Class III only.
➌ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➍ Change voltage suffix -TTCN to -MTCN for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.
 Shaded area indicates items suitable for Class I, Division 1, Group B.

1210 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

Description Catalog Number


Polyester Reflectors
Furnished with stainless steel screws
Standard Dome KR2-ST
30° Angle KR2-AN

Standard Dome 30° Angle


Three-Way Exit Sign
Epoxy enameled steel — 6”-high red lettering CJEXRN
Mounts to Code•Master Jr. fixture units in place of guard.

Lighting
Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering AEXR-15R
Mounts to Code•Master Jr. fixture units in place of guard.
*Contact your sales representative regarding hazardous location suitability.

Lighting: Explosionproof — Area — HID


Prismatic Glass Globe and Ring Assembly — 50 W through 175 W
CJGL-175

Aluminum Guards — 50 W through 175 W


CJGU-15

Replacement Sockets — 50 W through 175 W


Medium base sockets CJMS-175

Connection Block — 50 W through 175 W


For all Code•Master fixtures VPT-7

HPS Hot Restrike


Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only) Add suffix -R
Smart Starter
Smart Starter is for HPS fixtures only. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally start lamp.
Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs.
Optional for all HPS and PSMH fixtures. Add suffix -S

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1211


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire Ballast and Fuse Kit Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

NEC: CSA: V
Class I, Division 1 and 2, Groups B, C, D Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G Class II, Division 1 and 2, Groups E, F, G
Class III Class III
Marine type electric fixtures, outside type Type 4X
(salt water) Exd IIB + H2

Ballast Amps Fuse Kit Catalog Number


High Pressure Sodium Pulse Start Metal Halide Fuse
Lamp HX-H.P.F. ➊ HX-H.P.F. ➊ — Super CWA ➋ Quantity
Watts Volts Start Operating Start Operating Required HPS PSMH MH V
120 0.58 0.58 0.87 0.60 1 CF-5 CF-3 —
208 0.35 0.33 0.51 0.40 2 CF-3 CF-3 —
240 0.31 0.29 0.47 0.35 2 CF-3 CF-2 —
50
277 0.25 0.25 0.32 0.32 1 CF-2 CF-2 —
347 V — — — — — — — —
480 — — — — — — — —
120 0.90 0.82 0.80 0.85 1 CF-5 CF-5 —
Lighting

208 0.50 0.48 0.50 0.52 2 CF-3 CF-3 —


240 0.44 0.41 0.43 0.44 2 CF-3 CF-3 —
70
277 0.35 0.36 0.39 0.39 1 CF-2 CF-2 —
347 V 0.30 0.30 0.20 0.28 1 CF-2 CF-2 —
480 0.21 0.21 0.26 0.23 2 CF-2 CF-2 —
Lighting: Explosionproof — Area — HID

120 1.30 1.15 1.20 1.15 1 CF-8 CF-8 —


208 0.76 0.67 0.70 0.70 2 CF-5 CF-5 —
240 0.66 0.58 0.61 0.58 2 CF-5 CF-3 —
100
277 0.60 0.50 0.55 0.50 1 CF-3 CF-3 —
347 V 0.45 0.30 0.40 0.40 1 CF-2 CF-2 —
480 0.33 0.31 0.30 0.35 2 CF-3 CF-2 —
120 2.00 1.66 — — 1 CF-10 — —
208 1.16 0.96 — — 2 CF-5 — —
240 1.00 0.83 0.85 0.80 2 CF-5 CF-5 —
150
277 1.00 0.83 — — 1 CF-5 — —
347 V 0.52 0.56 0.55 0.65 1 CF-3 — —
480 0.88 0.75 — — 2 CF-5 — —
120 1.30 1.80 0.90 1.78 1 — CF-5 CF-5
208 0.75 1.04 0.50 1.08 2 — CF-3 CF-3
240 0.65 0.90 0.35 0.89 2 — CF-3 CF-3
175
277 0.55 0.80 0.30 0.76 1 — CF-2 CF-2
347 V 0.27 0.65 0.25 0.65 1 — CF-2 CF-2
480 0.35 0.45 0.25 0.50 2 — CF-2 CF-2

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 V and 277
V, and 2 fuses for 208, 240 and 480 V. CF-2 = 2 Amp; CF-3 = 3 Amp; CF-5 = 5 Amp; CF-8 = 8 Amp; CF-10 = 10 Amp
➊ 35 W through 150 W HPS and 50 W through 100 W PSMH have H.P.F. High Reactance ballasts.
➋ 175 W PSMH 480 volts has CWA ballast. Multi-tap has Super CWA ballast.
V CSA Certification only.

1212 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

Pendant Ceiling Bracket


0.41"/
10.4 mm Dia.
2.46"/ 2.28"/
62.5 mm 57.9 mm 4.25"/
4.58"/ 108.0 mm
116.3 mm Dia.
4.00"/ 4.92"/
3.75"/95.3 mm 101.6 mm 125.0 mm Sq.
4.50"/
17.22"/ 114.3 mm
437.4 mm
1.23"/
4.00"/ 3.92"/ 31.2 mm 1.79"/
101.6 mm 99.6 mm 3.46"/ 45.5 mm
7.40"/ 87.9 mm
188.0 mm 5.92"/ 11.5"/
17.87"/ 150.4 mm 292.1 mm
453.9 mm 13.75"/
349.3 mm

14.12"/
358.6 mm

Lighting
8.00"/
203.2 mm 17.47"/
443.7 mm 188.0 mm
7.40"/

18.12"/ 15.62"/
460.2 mm 7.40"/ 396.7 mm
188.0 mm
14.12"/ 16.25"/
358.6 mm 412.8 mm

Lighting: Explosionproof — Area — HID


8.00"/
203.2 mm
16.00"/
406.4 mm

25˚ Stanchion Exit Signs Reflectors

9.5"/ 8.00"/
241.3 mm 6.88"/ 203.2 mm
6.10"/ 174.8 mm
154.9 mm 2.75"/
69.9 mm
11.75"/298.5 mm

258.3 mm
4.5"/
60.5 mm Dia. 8.50"/ 10.17"/
2.38"/ 215.9 mm 14.9"/
60.5 mm Dia. 378.5 mm

1.5 - 11 NPT
AEXR-15R
30° Angle

9.25"/ 8.00"/
235.0 mm 203.2 mm
152.4 mm
6.00"/
428.8 mm
16.88"/
406.4 mm

12.00"/
16.00"/

304.8 mm
16.9"/
429.3 mm

CJEXRN Standard Dome

16.25"/
412.8 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1213


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire HPS Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

* Photometric data is based on a fixture with a 70 W (6,400 lumen) HPS lamp – 0.394;
a 150-watt clear High Pressure Sodium lamp for a 70 W (5800 lumen) HPS lamp – 0.363;
(16,000 lumen), without guard. For candlepower for a 50 W (4,000 lumen) HPS lamp – 0.25;
values of fixtures with other HPS lamps, use for a 35 W (2,250 lumen) HPS lamp – 0.141.
the following multipliers: For candlepower values of fixture with guard,
for a 100 W (9,500 lumen) HPS lamp – 0.594; for multiply by 0.95.

Zone Lumens Total Luminaire Efficiency = 77.5%


0-10 32.97 CIE Type - General Diffuse REPORT NUMBER: CJL15G
10-20 119.16 Lamps: 150 W High Pressure Sodium lamp with Globe only *
20-30 313.87
30-40 349.57 Coefficients of Utilization - Zonal Cavity Method
40-50 804.55 Effective Floor Cavity Reflectance 0.20
50-60 1193.29 % Ceiling Rcc 80 70 50 30 10 0
60-70 1327.33 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1576.23 Zonal Lumen Summary 0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 50 50 50 46
80-90 1672.01 Zone Lumens % Lamp % Fixture 1 72 66 61 57 67 61 57 53 52 49 45 44 41 38 36 34 32 28
90-100 1647.69 0-30 465.99 2.9 3.8 2 64 55 48 42 58 51 44 39 43 38 33 35 31 28 29 26 23 19
100-110 1507.22 0-40 815.56 5.1 6.6 3 57 47 39 33 52 43 36 30 36 30 26 30 25 21 24 20 17 14
110-120 1221.25 0-60 2813.41 17.6 22.7 4 51 40 32 26 47 37 30 24 31 25 21 25 21 17 20 16 13 10
120-130 607.81 0-90 7388.98 46.2 59.6 5 46 35 27 21 42 32 25 20 27 21 17 22 17 14 18 14 11 8
130-140 27.17 90-120 4376.17 27.4 35.3 6 42 31 23 18 39 29 22 17 24 18 14 20 15 11 16 12 9 6
Lighting

140-150 1.62 90-130 4983.97 31.1 40.2 7 39 28 20 15 36 26 19 14 21 16 12 18 13 10 14 10 7 5


150-160 0.35 90-150 5012.76 31.3 40.2 8 36 25 18 13 33 23 17 12 19 14 10 16 11 8 13 9 6 4
160-170 0.07 90-180 5013.20 31.3 40.4 9 33 23 16 11 31 21 15 10 18 12 9 15 10 7 12 8 6 4
170-180 0.02 180-0 12402.18 77.5 100.0 10 31 21 14 10 29 19 13 9 16 11 8 13 9 6 11 7 5 3

Zone Lumens Total Luminaire Efficiency = 66.9%


0-10 249.34 CIE Type - Direct
REPORT NUMBER: CJL15ST
10-20 810.25
Lamps: 150 W High Pressure Sodium lamp with
Spacing
Lighting: Explosionproof — Area — HID

20-30 1450.35 Plane Criteria Standard Dome Reflector


30-40 1495.68 0-180 1.44 Coefficients of Utilization - Zonal Cavity Method
40-50 1920.69 90-270 1.44 Effective Floor Cavity Reflectance 0.20
50-60 2259.61 Diagonal 1.80 % Ceiling Rcc 80 70 50 30 10 0
60-70 1846.14 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 541.69 Zonal Lumen Summary 0 80 80 80 80 78 78 78 78 74 74 74 71 71 71 68 68 68 67
80-90 125.07 Zone Lumens % Lamp % Fixture 1 73 69 66 64 71 68 65 63 65 63 61 62 61 59 60 59 57 56
90-100 0.70 0-30 2509.94 15.7 23.5 2 66 60 55 51 64 59 54 51 56 53 49 54 51 48 52 49 47 46
100-110 0.00 0-40 4005.62 25.0 37.4 3 59 52 46 42 58 51 46 41 49 44 41 47 43 40 45 42 39 38
110-120 0.00 0-60 8185.92 51.2 76.5 4 54 45 39 35 52 45 39 34 43 38 34 41 37 33 40 36 33 31
120-130 0.00 0-90 10698.82 66.9 100.0 5 49 40 34 29 48 39 33 29 38 33 29 37 32 28 35 31 28 27
130-140 0.00 90-120 0.70 0.0 0.0 6 45 36 30 25 44 35 29 25 34 29 25 33 28 24 32 27 24 23
140-150 0.00 90-130 0.70 0.0 0.0 7 42 32 26 22 40 32 26 22 31 25 21 30 25 21 29 24 21 20
150-160 0.00 90-150 0.70 0.0 0.0 8 39 29 23 19 38 29 23 19 28 23 19 27 22 19 26 22 19 17
160-170 0.00 90-180 0.70 0.0 0.0 9 36 27 21 17 35 26 21 17 25 20 17 25 20 17 24 20 17 15
170-180 0.00 180-0 10699.52 66.9 100.0 10 34 24 19 15 33 24 19 15 23 19 15 23 18 15 22 18 15 14

Zone Lumens Total Luminaire Efficiency = 61.8%


REPORT NUMBER: CJL15AN
0-10 58.31 CIE Type - Direct
10-20 482.43
Lamps: 150 W High Pressure Sodium lamp with
Spacing
20-30 904.49 Plane Criteria 30° Angle Dome Reflector
30-40 1163.85 0-180 2.08 Coefficients of Utilization - Zonal Cavity Method
40-50 1479.08 90-270 1.38 Effective Floor Cavity Reflectance 0.20
50-60 1630.56 Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0
60-70 1467.51 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1258.91 Zonal Lumen Summary 0 73 73 73 73 71 71 71 71 67 67 67 64 64 64 61 61 61 60
80-90 1077.10 Zone Lumens % Lamp % Fixture 1 64 59 55 52 61 58 54 51 54 51 49 51 49 47 49 47 45 43
90-100 153.91 0-30 1445.23 9.0 14.6 2 56 50 44 40 54 48 43 39 46 41 38 43 39 36 41 38 35 33
100-110 155.65 0-40 2609.08 16.3 26.4 3 51 43 36 31 49 41 36 31 39 34 30 37 33 29 35 31 28 27
110-120 52.23 0-60 5718.73 35.7 57.8 4 46 37 30 25 44 36 30 25 34 29 24 32 28 24 30 26 23 22
120-130 8.33 0-90 9522.24 59.5 96.3 5 42 32 26 21 40 32 25 21 30 25 20 28 24 20 27 23 19 18
130-140 0.10 90-120 361.80 2.3 3.7 6 38 29 22 18 37 28 22 18 27 21 17 25 21 17 24 20 17 15
140-150 0.00 90-130 370.13 2.3 3.7 7 35 26 20 15 34 25 19 15 24 19 15 23 18 15 22 17 14 13
150-160 0.00 90-150 370.23 2.3 3.7 8 33 23 17 13 31 23 17 13 22 17 13 21 16 13 20 16 12 11
160-170 0.00 90-180 370.23 2.3 3.7 9 30 21 16 12 29 21 15 12 20 15 11 19 14 11 18 14 11 10
170-180 0.00 180-0 9892.48 61.8 100.0 10 28 19 14 10 27 19 14 10 18 13 10 17 13 10 17 13 10 9

1214 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire PSMH Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

* Photometric data is based on a fixture with for a 70 W (5,000 lumen) PSMH lamp – 0.357.
a 175-watt clear Pulse Start Metal Halide For candlepower values of fixture with guard,
lamp (14,000 lumen), without guard. For multiply by – 0.95.
candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for a 100 W (8,500 lumen) PSMH lamp – 0.607;

Zone Lumens Total Luminaire Efficiency = 77.8%


0-10 46.64 CIE Type - General Diffuse REPORT NUMBER: CJP17G
10-20 176.99 Lamps: 175 W Pulse Start Metal Halide with Globe only *
20-30 380.01
30-40 480.30 Coefficients of Utilization - Zonal Cavity Method
40-50 1042.35 Effective Floor Cavity Reflectance 0.20
50-60 1252.88 % Ceiling Rcc 80 70 50 30 10 0
60-70 1378.40 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1611.81 Zonal Lumen Summary 0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 51 51 51 46
80-90 1741.68 Zone Lumens % Lamp % Fixture 1 73 67 62 58 67 62 58 54 53 49 46 45 42 39 37 35 33 29
90-100 1758.28 0-30 603.64 3.4 4.4 2 64 56 49 43 59 52 45 40 44 39 35 36 32 29 30 27 24 20
100-110 1643.71 0-40 1083.94 6.2 8.0 3 57 48 40 34 53 44 37 31 37 31 27 31 26 22 25 21 18 15
110-120 1371.76 0-60 3379.18 19.3 24.8 4 52 41 33 27 48 38 31 25 32 26 22 26 22 18 21 17 14 12
120-130 694.24 0-90 8111.07 46.3 59.6 5 47 36 28 22 43 33 26 21 28 22 18 23 18 15 19 15 12 9
130-140 27.13 90-120 4773.75 27.3 35.1 6 43 32 24 19 40 29 23 18 25 19 15 20 16 12 16 13 10 7

Lighting
140-150 3.14 90-130 5467.99 31.2 40.2 7 40 28 21 16 36 26 20 15 22 17 13 18 14 10 15 11 8 6
150-160 0.67 90-150 5498.26 31.4 40.2 8 37 26 19 14 34 24 17 13 20 15 11 17 12 9 13 10 7 5
160-170 0.08 90-180 5499.05 31.4 40.4 9 34 23 17 12 31 21 15 11 18 13 9 15 11 8 12 9 6 4
170-180 0.03 180-0 13610.12 77.8 100.0 10 32 21 15 11 29 20 14 10 17 12 8 14 10 7 11 8 5 4

Zone Lumens Total Luminaire Efficiency = 66.4%


REPORT NUMBER: CJP17ST
0-10 281.17 CIE Type - Direct
10-20 914.71
Lamps: 175 W Pulse Start Metal Halide with
Spacing

Lighting: Explosionproof — Area — HID


20-30 1567.70 Plane Criteria Standard Dome Reflector *
30-40 1691.30 0-180 1.42 Coefficients of Utilization - Zonal Cavity Method
40-50 2211.91 90-270 1.42 Effective Floor Cavity Reflectance 0.20
50-60 2339.53 Diagonal 1.76 % Ceiling Rcc 80 70 50 30 10 0
60-70 1900.87 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 568.93 Zonal Lumen Summary 0 79 79 79 79 77 77 77 77 74 74 74 71 71 71 68 68 68 66
80-90 145.98 Zone Lumens % Lamp % Fixture 1 72 69 66 64 70 67 65 63 65 63 61 62 60 59 60 58 57 56
90-100 1.23 0-30 2763.57 15.8 23.8 2 65 60 55 51 64 58 54 51 56 52 49 54 51 48 52 49 47 46
100-110 0.00 0-40 4454.87 25.5 38.3 3 59 52 46 42 57 51 46 41 49 44 41 47 43 40 45 42 39 38
110-120 0.00 0-60 9006.31 51.5 77.5 4 54 46 39 35 52 45 39 35 43 38 34 41 37 34 40 36 33 32
120-130 0.00 0-90 11622.09 66.4 100.0 5 49 40 34 29 48 40 34 29 38 33 29 37 32 29 35 31 28 27
130-140 0.00 90-120 1.23 0.0 0.0 6 45 36 30 25 44 35 29 25 34 29 25 33 28 25 32 28 24 23
140-150 0.00 90-130 1.23 0.0 0.0 7 42 32 26 22 41 32 26 22 31 26 22 30 25 22 29 25 21 20
150-160 0.00 90-150 1.23 0.0 0.0 8 39 29 23 19 38 29 23 19 28 23 19 27 22 19 26 22 19 18
160-170 0.00 90-180 1.23 0.0 0.0 9 36 27 21 17 35 26 21 17 26 21 17 25 20 17 24 20 17 16
170-180 0.00 180-0 11623.32 66.4 100.0 10 34 25 19 16 33 24 19 16 24 19 15 23 18 15 22 18 15 14

Zone Lumens Total Luminaire Efficiency = 63.2%


REPORT NUMBER: CJP17AN
0-10 238.28 CIE Type - Direct
10-20 739.68
Lamps: 175 W Pulse Start Metal Halide with
Spacing
20-30 1242.92 Plane Criteria 30° Angle Dome Reflector *
30-40 1491.36 0-180 2.10 Coefficients of Utilization - Zonal Cavity Method
40-50 1770.34 90-270 1.60 Effective Floor Cavity Reflectance 0.20
50-60 1739.56 Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
60-70 1484.79 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1197.57 Zonal Lumen Summary 0 75 75 75 75 73 73 73 73 69 69 69 65 65 65 62 62 62 61
80-90 689.02 Zone Lumens % Lamp % Fixture 1 66 63 59 56 64 61 58 55 58 55 53 55 53 51 52 50 49 47
90-100 254.20 0-30 2220.87 12.7 20.1 2 60 53 48 44 58 52 47 43 49 45 42 47 43 41 44 42 39 38
100-110 105.48 0-40 3712.23 21.2 33.6 3 54 46 40 36 52 45 40 35 43 38 34 41 37 33 39 35 32 31
110-120 35.72 0-60 7222.13 41.3 65.3 4 49 41 34 30 47 39 34 29 38 33 29 36 31 28 34 30 27 26
120-130 41.95 0-90 10593.52 60.5 95.8 5 45 36 30 25 43 35 29 25 33 28 24 32 27 24 30 26 23 22
130-140 8.72 90-120 395.41 2.3 3.6 6 41 32 26 22 40 31 26 21 30 25 21 29 24 21 27 23 20 19
140-150 6.06 90-130 437.36 2.5 4.0 7 38 29 23 19 37 28 23 19 27 22 18 26 21 18 25 21 18 16
150-160 4.53 90-150 452.13 2.6 4.0 8 35 26 21 17 34 26 20 17 25 20 16 24 19 16 23 19 16 14
160-170 2.20 90-180 459.54 2.6 4.2 9 33 24 19 15 32 24 18 15 23 18 15 22 17 14 21 17 14 13
170-180 0.68 180-0 11053.05 63.2 100.0 10 31 22 17 13 30 22 17 13 21 16 13 20 16 13 19 15 13 12

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1215


© September 2010
Code•Master 2™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC: CEC: V CSA Type 4X
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Exd IIB, Zone 1
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2; IIB, IIA
Class III Class II, Division 1, Groups E, F, G
Marine Type Electric Fixtures Class II, Division 2, Groups F, G
Outside Type (Salt Water) Class III

Applications
• Ideal for use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries; and
in other process areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
• Suitable for use in wet locations.
Features
• Fixtures operate safely in high ambient temperatures. For
example, in Class I areas the 150 W HPS fixture operates
at a maximum temperature of 248 ˚ F/120 °C in a 149 ˚F/
65 °C ambient (212 ˚F/100 °C temperature in a 104 °F/40 °C
ambient).
• Arrangement of heat-producing components results in
more efficient heat dissipation for cooler fixture operation.
• Patented “wireless” design. Threading of fixture unit onto
Lighting

mounting hood makes electrical connection. Only wiring


required is attaching two wires to connection block in mounting
hood.
• Connection block is easily wired: (a) loosen two screws, (b)
make wire connections and (c) re-position connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit easily threads off mounting hood for
convenient servicing or for immediate replacement with a
Lighting: Explosionproof — Area — HID

“stand-by” unit.
• Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single lead threads during fixture unit removal. Standard Materials
• All threaded joints are flame-tight. • Ballast bodies and guards: copperfree (4/10 of 1% max.)
• Integrally ballasted HID lighting fixtures; separate ballasts aluminum
not required. • Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
• Factory sealed. External seals not required. aluminum
• Strategic location of lamp socket in combination with the • Ceiling, bracket and stanchion mounting hoods: sand cast
interior prism design of the glass globe provides optimum copperfree (4/10 of 1% max.) aluminum
light distribution and control. • Reflectors: aluminum or fiberglass reinforced polyester
• Superior corrosion resistance, with epoxy powder coat finish.
• Porcelain socket with nickel-plated phosphor bronze Standard Finishes
screw shell. Assures long trouble-free operation in high ambient • Ballast bodies, guards and mounting hoods: epoxy powder
areas. coat finish, electrostatically applied for complete, uniform
• Choice of mountings: pendant, ceiling, bracket and stanchion. corrosion protection
• Fiberglass-reinforced polyester reflectors, in standard
dome, deep dome or 30° angle, are ideal in installations
Options
where luminaire is subject to exceptionally severe corrosive • Fuses for field installation can be ordered by catalog number
atmospheres. The high bay aluminum reflector is indicated in from fuse kit table.
installations where mounting height from work plane ranges • Quartz Auxiliary Emergency Lamp for PSMH/MH and HPS
from 20 feet/6 meters and higher. fixtures. Relay switch installed in fixture. Add suffix -E to fixture
• Optional guards protect globes from damage. Secured to fixture catalog number.
with three screws. • Smart Hot Restrike Option available for 50 W through 150 W
• Light sources: high pressure sodium, pulse start metal halide or HPS only. Add suffix -SR.
metal halide. HPS is excellent where long lamp life is required. • Hot Restrike Option available for 50 W through 150 W HPS only.
HPS provides high lumens per watt and is less expensive to Add suffix –R.
operate. PSMH/MH is desirable where colors of illuminated • Smart Starter Option available for 50 W through 400 W HPS
areas must be close to natural. PSMH/MH provides better color and PSMH/MH. Add suffix –S.
rendition, increased lumen output, longer lamp life, and faster Certifications and Compliances
restrike after momentary power interruption.
• UL Standard: UL 1598, UL 844
• A wide range of ballasts and voltages are available for both
• UL Listed: E10444
domestic and export applications.
• CSA Standard: C22.2 No. 250, C22.2 No. 137
• Ballasts operate at low temperatures – PSMH: -20 °F/-29 ˚C;
• CSA Certified: 025428
HPS: -40 °F/-40 ˚C; MH: -31 °F/-35 ˚C.
• 50 W through 150 W high pressure sodium ballasts are high
reactance, high power factor type. V CSA Certification only.

1216 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Technical Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC: CEC: V CSA Type 4X
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Exd IIB, Zone 1
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2; IIB, IIA
Class III Class II, Division 1, Groups E, F, G
Marine Type Electric Fixtures Class II, Division 2, Groups F, G
Outside Type (Salt Water) Class III

Classified Area Suitability of Code•Master 2 Series HID Fixtures — Suitability includes use of reflector
Class II, Division 1 & 2
Class I, Division 1 & 2 With Globe or with With Globe or with Globe & Reflector
Globe & Reflector UL/NEC/CEC Temp. Ident. No. UL/NEC/CEC Temp. Ident. No. ➊
Lamp Lamp Supply Wire Ambient Temp NEC CEC V
Type Watts (°F/˚°C) (°F/°˚C) Nameplate Marking Groups Groups Nameplate Marking Groups
50 122/60 104/40 T6 C,D B, C, D T4 E,F,G
50 167/75 131/55 T5 C,D B, C, D — —
50 185/85 149/65 T5 C,D B, C, D — —
70 140/60 104/40 T6 C,D B, C, D T4 E,F,G
70 167/75 131/55 T5 C,D B, C, D — —
70 185/85 149/65 T5 C,D B, C, D — —

Lighting
High 100 122/60 104/40 T5 C,D B, C, D T4 E,F,G
Pressure
Sodium 100 167/75 131/55 T5 C,D B, C, D — —
100 185/85 149/65 T4A C,D B, C, D — —
150 122/60 104/40 T5 C,D B, C, D T3A E,F
150 167/75 131/55 T4A C,D B, C, D T3 —

Lighting: Explosionproof — Area — HID


250 167/75 104/40 T3C C,D B, C, D — —
250 167/75 131/55 T3C C,D B, C, D — —
400 185/85 104/40 T3C C,D B, C, D — —
175 167/75 104/40 T4 C,D B, C, D T3C E,F,G
250 167/75 104/40 T4 C,D B, C, D T3A E,F
Pulse Start
320 167/75 104/40 T3C C,D B, C, D — —
Metal Halide
350 167/75 104/40 T3C C,D B, C, D — —
400 167/75 104/40 T3C C,D B, C, D — —
175 167/75 104/40 T4 ­— B, C, D T3C E, F, G
Metal Halide V 250 167/75 104/40 T4 — B, C, D T3A E, F
400 167/75 104/40 T3C — B, C, D — —

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 12
(°F)
Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
➊ Applies to Code•Master 2 only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1217


© September 2010
Code•Master 2™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof. Groups C and D Applications
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

ANSI Lamp Type Catalog Number ➋➌


Lamp Hub Size
Watts HPS PSMH (Inches) HPS PSMH
Pendant — One Hub, Rigid or Flexible Mounting
3/4 CLP5075 ➊ —
50 S68 —
1 CLP5010 ➊ —
3/4 CLP7075 —
70 S62 —
1 CLP7010 —
3/4 CLP1075 —
100 S54 —
1 CLP1010 —
3/4 CLP1575 —
150 S55 —
1 CLP1510 —
Lighting

3/4 — CPP1775
175 — M152
1 — CPP1710
3/4 CLP2575 CPP2575
250 S50 M153
1 CLP2510 CPP2510
3/4 — CPP3275
320 — M154
1 — CPP3210
Lighting: Explosionproof — Area — HID

3/4 — CPP3575
350 — M131
1 — CPP3510
3/4 CLP4075 CPP4075
400 S51 M155
1 CLP4010 CPP4010
Ceiling — Four Hubs, Three Close-Up Plugs
3/4 CLC5075 ➊ —
50 S68 —
1 CLC5010 ➊ —
3/4 CLC7075 —
70 S62 —
1 CLC7010 —
3/4 CLC1075 —
100 S54 —
1 CLC1010 —
3/4 CLC1575 —
150 S55 —
1 CLC1510 —
3/4 — CPC1775
175 — M152
1 — CPC1710
3/4 CLC2575 CPC2575
250 S50 M153
1 CLC2510 CPC2510
3/4 — CPC3275
320 — M154
1 — CPC3210
3/4 — CPC3575
350 — M131
1 — CPC3510
3/4 CLC4075 CPC4075
400 S51 M155
1 CLC4010 CPC4010

➊ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➋ Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V.
 To order fixture with guard, add suffix -G (before adding voltage suffix).
 Shaded items are suitable for Class I, Group D ONLY.

1218 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof. Groups C and D Applications
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

ANSI Lamp Type Catalog Number ➋➌


Lamp Hub Size
Watts HPS PSMH (Inches) HPS PSMH
Bracket - Four Hubs, Three Close-Up Plugs
3/4 CLB5075 ➊ —
50 S68 —
1 CLB5010 ➊ —
3/4 CLB7075 —
70 S62 —
1 CLB7010 —
3/4 CLB1075 —
100 S54 —
1 CLB1010 —
3/4 CLB1575 —
150 S55 —
1 CLB1510 —

Lighting
3/4 — CPB1775 ➋
175 — M152
1 — CPB1710 ➋
3/4 CLB2575 CPB2575 ➋
250 S50 M153
1 CLB2510 CPB2510 ➋
3/4 — CPB3275 ➋
320 — M154
1 —

Lighting: Explosionproof — Area — HID


CPB3210 ➋
3/4 — CPB3575 ➋
350 — M131
1 — CPB3510 ➋
3/4 CLB4075 CPB4075 ➋
400 S51 M155
1 CLB4010 CPB4010 ➋
25° Stanchion - One Hub

50 S68 — 1-1/4 or 1-1/2 ➍ CLS50150 ➊ —

70 S62 — 1-1/4 or 1-1/2 ➍ CLS70150 —

100 S54 — 1-1/4 or 1-1/2 ➍ CLS10150 —

150 S55 — 1-1/4 or 1-1/2 ➍ CLS15150 —

175 — M152 1-1/4 or 1-1/2 ➍ — CPS17150 ➋

250 S50 M153 1-1/4 or 1-1/2 ➍ CLS25150 CPS25150 ➋

320 — M154 1-1/4 or 1-1/2 ➍ — CPS32150 ➋

350 — M131 1-1/4 or 1-1/2 ➍ — CPS35150 ➋

400 S51 M155 1-1/4 or 1-1/2 ➍ CLS40150 ➋ CPS40150 ➋

➊ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➋ Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V.
 To order fixture with guard, add suffix -G (before adding voltage suffix).
➍ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
 Shaded items are suitable for Class I, Group D ONLY.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1219


© September 2010
Code•Master 2™ HID Factory Sealed Luminaires V
Explosionproof, Dust-Ignitionproof. Groups B, C and D Applications
Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH.
Mogul Base. For use with threaded metal conduit.
CEC: V CSA Type 4X
Class I, Division 1 and 2, Groups B, C, D Exd IIB, Zone 1
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

ANSI Lamp Type Hub Catalog Number ❶❷


Lamp Size
Watts HPS PSMH MH (Inches) HPS PSMH MH
Pendant — One Hub, Rigid or Flexible Mounting
3/4 CLP7075TTCN — —
70 S62 — —
1 CLP7010TTCN — —
3/4 CLP1075TTCN — —
100 S54 — —
1 CLP1010TTCN — —
3/4 CLP1575TTCN — —
150 S55 — —
1 CLP1510TTCN — —
3/4 — CPP1775TTCN CHP1775TTCN
175 — M152 M57
1 — CPP1710TTCN CHP1710TTCN
Lighting

3/4 CLP2575TTCN CPP2575TTCN CHP2575TTCN


250 S50 M153 M58
1 CLP2510TTCN CPP2510TTCN CHP2510TTCN
3/4 — CPP3275TTCN —
320 — M154 —
1 — CPP3210TTCN —
3/4 — CPP3575TTCN —
350 — M131 —
1 — CPP3510TTCN —
Lighting: Explosionproof — Area — HID

3/4 CLP4075TTCN CPP4075TTCN CHP4075TTCN


400 S51 M155 M59
1 CLP4010TTCN CPP4010TTCN CHP4010TTCN
Ceiling — Four Hubs, Three Close-Up Plugs
3/4 CLC7075TTCN — —
70 S62 — —
1 CLC7010TTCN — —
3/4 CLC1075TTCN — —
100 S54 — —
1 CLC1010TTCN — —
3/4 CLC1575TTCN — —
150 S55 — —
1 CLC1510TTCN — —
3/4 — CPC1775TTCN CHC1775TTCN
175 — M152 M57
1 — CPC1710TTCN CHC1710TTCN
3/4 CLC2575TTCN CPC2575TTCN CHC2575TTCN
250 S50 M153 M58
1 CLC2510TTCN CPC2510TTCN CHC2510TTCN
3/4 — CPC3275TTCN —
320 — M154 —
1 — CPC3210TTCN —
3/4 — CPC3575TTCN —
350 — M131 —
1 — CPC3510TTCN —
3/4 CLC4075TTCN CPC4075TTCN CHC4075TTCN
400 S51 M155 M59
1 CLC4010TTCN CPC4010TTCN CHC4010TTCN

➊ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
❷ To order fixture with guard, add suffix -G (before adding voltage suffix).
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.

1220 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Luminaires V
Explosionproof, Dust-Ignitionproof. Groups B, C and D Applications
Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH.
Mogul Base. For use with threaded metal conduit.
CEC: V CSA Type 4X
Class I, Division 1 and 2, Groups B, C, D Exd IIB, Zone 1
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

ANSI Lamp Type Hub Catalog Number ❶❷


Lamp Size
Watts HPS PSMH MH (Inches) HPS PSMH MH
Bracket - Four Hubs, Three Close-Up Plugs
3/4 CLB7075TTCN — —
70 S62 — —
1 CLB7010TTCN — —
3/4 CLB1075TTCN — —
100 S54 — —
1 CLB1010TTCN — —
3/4 CLB1575TTCN — —
150 S55 — —
1 CLB1510TTCN — —
3/4 — CPB1775TTCN CHB1775TTCN
175 — M152 M57
1 — CPB1710TTCN CHB1710TTCN

Lighting
3/4 CLB2575TTCN CPB2575TTCN CHB2575TTCN
250 S50 M153 M58
1 CLB2510TTCN CPB2510TTCN CHB2510TTCN
3/4 — CPB3275TTCN —
320 — M154 —
1 — CPB3210TTCN —
3/4 — CPB3575TTCN —
350 — M131 —
1 — CPB3510TTCN —

Lighting: Explosionproof — Area — HID


3/4 CLB4075TTCN CPB4075TTCN CHB4075TTCN
400 S51 M155 M59
1 CLB4010TTCN CPB4010TTCN CHB4010TTCN
25° Stanchion - One Hub

70 S62 — — 1-1/4 or 1-1/2 ➌ CLS70150TTCN — —

100 S54 — — 1-1/4 or 1-1/2 ➌ CLS10150TTCN — —

150 S55 — — 1-1/4 or 1-1/2 ➌ CLS15150TTCN — —

175 — M152 M57 1-1/4 or 1-1/2 ➌ — CPS17150TTCN CHS17150TTCN

250 S50 M153 M58 1-1/4 or 1-1/2 ➌ CLS25150TTCN CPS25150TTCN CHS25150TTCN

320 — M154 — 1-1/4 or 1-1/2 ➌ — CPS32150TTCN —

350 — M131 — 1-1/4 or 1-1/2 ➌ — CPS35150TTCN —

400 S51 M155 M59 1-1/4 or 1-1/2 ➌ CLS40150TTCN CPS40150TTCN CHS40150TTCN

➊ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
❷ To order fixture with guard, add suffix -G (before adding voltage suffix).
➌ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1221


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC: CEC: V CSA Type 4X
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Exd IIB, Zone 1
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2; IIB, IIA
Class III Class II, Division 1, Groups E, F, G
Marine Type Electric Fixtures Class II, Division 2, Groups F, G
Outside Type (Salt Water) Class III

Mounting Hoods
Hub Size (Inches) Catalog Number
Pendant — One Hub
3/4 CAP-75

1 CAP-100
Ceiling — Four Hubs, Three Close-Up Plugs

3/4 CAC-75

1 CAC-100

Bracket — Four Hubs, Three Close-Up Plugs


Lighting

3/4 CALB-75

1 CALB-100

25˚ Stanchion — One Hub


1-1/4 or 1-1/2 ➊ CAS-150
Lighting: Explosionproof — Area — HID

Mounting Adapter with Connection Block


Permits use of existing A-51 mounting hoods (AAC Ceiling
or AALB Bracket) with the new Code•Master 2 Fixture Unit.
After removing existing fixture unit and adapter, screw in CMAD-1
the new CMAD-1 Adapter. Then thread new fixture unit into
the CMAD-1.

Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below.
Add Voltage Suffixes
Lamp Fixture Unit
Type Watts Number 120/208/240/277 120/277/347 V➌ 480 V
50 CMBL50 MT TTCN —
70 CMBL70 MT TTCN 48
High Pressure Sodium
100 CMBL100 MT TTCN 48
High Power Factor
150 CMBL150 MT TTCN 48
(Min. P.F. 90%)
250 CMBL250 MT TTCN 48
400 CMBL400 MT TTCN 48
175 CMBP175 MT TTCN 48
Pulse Start Metal Halide 250 CMBP250 MT TTCN 48
Constant Wattage 320 CMBP320 MT TTCN 48
(Min. P.F. 90%) 350 CMBP350 MT TTCN 48
400 CMBP400 MT TTCN 48
Metal Halide V 175 CMBH175 MT TT C6
Constant Wattage 250 CMBH250 MT TT C6
(Min. P.F. 90%) 400 CMBH400 MT TT C6

➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.


➋ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➌ Change voltage suffix -TTCN to -MTCN for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.

1222 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.

Description Catalog Number


Polyester Reflectors — 50 W - 400 W
Standard Dome CMR-4ST
Deep Dome CMR-4DD
30˚ Angle CMR-4AN

Aluminum High Bay Reflectors — 50 W - 400 W


CMR-4HB

Lighting
Prismatic Glass Globes — 50 W - 400 W
50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH CGL-250
250, 400 W HPS; 320, 350, 400 W PSMH; 400 W MH CGL-400

Lighting: Explosionproof — Area — HID


Aluminum Guards — 50 W - 400 W
50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH CGU2
250, 400 W HPS; 320, 350, 400 W PSMH; 400 W MH CGU4

Replacement Sockets — 50 W - 400 W (Mogul Base)


For all Code•Master 2 HID fixtures CMS-400
Connection Block – 50 W through 400 W
For all Code•Master 2 HID fixtures VPT-7

Quartz Emergency Option for Pulse Start Metal Halide and High Pressure Sodium Fixtures
Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp (lamp not included). This D.C. bayonet base socket is
in addition to the standard lamp socket, independent of the lighting fixture voltage.
Add suffix -E
HPS Smart Hot Restrike
Smart Hot Restrike will immediately restrike an HPS lamp when power is restored after a momentary power interruption. The smart function
removes the hot restrike ignitor from the circuit if the lamp burns out or is removed from the socket. Eliminates starter failures caused by
prolonged operation with cycling or failing lamps and simplifies finding their location, reducing maintenance and repair costs.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only) Add suffix -SR
HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only) Add suffix -R
HPS Smart Starter
Smart Starter is for HPS fixtures only. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally start lamp.
Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs.
Optional for all HPS fixtures. Add suffix -S

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1223


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Ballast and Fuse Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC: CEC: V CSA Type 4X
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Exd IIB, Zone 1
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2; IIB, IIA
Class III Class II, Division 1, Groups E, F, G
Marine Type Electric Fixtures Class II, Division 2, Groups F, G
Outside Type (Salt Water) Class III

Ballast Amps Fuse Kit Catalog Number


High Pressure Pulse Start Metal Halide Metal Halide Fuse
Lamp Sodium ➊ Super CWA CWA Quantity
Watts Volts Start Operating Start Operating Start Operating Required HPS PSMH MH V
120 0.58 0.58 — — — — 1 CF-5 — —
208 0.35 0.33 — — — — 2 CF-3 — —
50 240 0.31 0.29 — — — — 2 CF-3 — —
277 0.25 0.25 — — — — 1 CF-2 — —
347 — — — — — — — — — —
480 — — — — — — — — — —
120 0.90 0.82 — — — — 1 CF-5 — —
208 0.50 0.48 — — — — 2 CF-3 — —
240 0.44 0.44 — — — — 2 CF-3 — —
70 277 0.35 0.36 — — — — 1 CF-2 — —
347 0.30 0.30 — — — — 1 CF-2 — —
480 0.21 0.21 — — — — 2 CF-2 — —
Lighting

120 1.30 1.15 — — — — 1 CF-8 — —


208 0.76 0.67 — — — — 2 CF-5 — —
100 240 0.66 0.58 — — — — 2 CF-5 — —
277 0.60 0.50 — — — — 1 CF-3 — —
347 0.45 0.39 — — — — 1 CF-3 — —
480 0.33 0.29 — — — — 2 CF-3 — —
120 2.00 1.66 — — — — 1 CF-10 — —
208 1.16 0.96 — — — — 2 CF-5 — —
Lighting: Explosionproof — Area — HID

150 240 1.00 0.83 — — — — 2 CF-5 — —


277 0.88 0.75 — — — — 1 CF-5 — —
347 0.52 0.56 — — — — 1 CF-5 — —
480 0.50 0.44 — — — — 2 CF-3 — —
120 — — 1.10 1.86 1.30 1.80 1 — CF-5 CF-5
208 — — 0.75 1.23 0.75 1.10 2 — CF-3 CF-3
175 240 — — 0.65 0.98 0.65 0.90 2 — CF-3 CF-3
277 — — 0.55 0.87 0.55 0.80 1 — CF-2 CF-2
347 — — 0.25 0.65 0.50 0.65 1 — CF-2 CF-2
480 — — 0.25 0.50 — — 2 — CF-2 —
120 1.75 2.70 1.96 2.50 1.20 2.60 1 CF-8 CF-8 CF-8
208 1.00 1.50 1.13 1.45 0.65 1.50 2 CF-5 CF-5 CF-5
240 0.85 1.30 0.98 1.25 0.60 1.30 2 CF-5 CF-5 CF-5
250
277 0.75 1.15 0.85 1.10 0.50 1.12 1 CF-5 CF-3 CF-3
347 0.60 0.93 0.62 0.90 0.80 0.90 1 CF-5 CF-3 CF-3
480 0.40 0.65 0.32 0.67 — — 2 CF-2 CF-2 —
120 — — 3.30 3.25 — — 1 — CF-8 —
208 — — 1.90 1.90 — — 2 — CF-6 —
240 — — 1.60 1.65 — — 2 — CF-5 —
320
277 — — 1.40 1.40 — — 1 — CF-5 —
347 — — 0.70 1.10 — — 1 — CF-5 —
480 — — 0.45 0.85 — — 2 — CF-3 —
120 — — 3.60 3.70 — — 1 — CF-10 —
208 — — 2.10 2.10 — — 2 — CF-8 —
240 — — 1.80 1.80 — — 2 — CF-5 —
350
277 — — 1.60 1.60 — — 1 — CF-5 —
347 — — 0.70 1.01 — — 1 — CF-5 —
480 — — 0.60 0.90 — — 2 — CF-3 —
120 3.10 3.90 3.50 4.00 3.25 4.00 1 CF-15 CF-10 CF-10
208 1.80 2.25 2.00 2.30 1.90 2.30 2 CF-8 CF-8 CF-8
240 1.60 1.95 1.75 2.00 1.65 2.00 2 CF-5 CF-5 CF-5
400
277 1.35 1.70 1.50 1.75 1.40 1.75 1 CF-5 CF-5 CF-5
347 1.00 1.32 1.10 1.35 1.20 1.40 1 CF-5 CF-5 CF-5
480 0.80 1.00 0.75 1.00 — — 2 CF-5 CF-3 —

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V,
and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp
➊ 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts.
V CSA Certification only.

1224 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.

Pendant Ceiling Bracket 25° Stanchion


0.41"/
10.4 mm Dia. 9.5"/
2.46"/ 2.28"/ 241.3 mm
62.5 mm 57.9 mm
6.10"/
154.9 mm

4.58"/ 4.92"/ 4.25"/


116.3 mm 125.0 mm Sq. 108.0 mm
4.50"/ 4.5"/
3.91"/ 114.3 mm
60.5 mm Dia.
99.3 mm 4.00"/
1.23"/
1.79"/ 2.38"/
101.6 mm 3.92"/ 31.2 mm 60.5 mm Dia.
99.6 mm 3.46"/ 45.5 mm
5.92"/ 87.9 mm 11.5"/
151.1 mm 292.1 mm
9.86"/ 0.94"/ 13.75"/
250.4 mm 23.9 mm 349.3 mm

9.86"/
250.4 mm
9.86"/
250.4 mm

Lighting
5.50"/

Lighting: Explosionproof — Area — HID


139.7 mm
Dimensions in In/mm
Pendant Ceiling Bracket 25° Stanchion
A B C D A B C D A B C D A B C
21.50/ 20.50/ 12.00/ 17.61/ 21.61/ 20.61/ 12.00/ 17.61/ 21.86/ 20.86/ 17.50/ 17.61/ 19.50/ 18.70/ 16.00/
50-250 W ➊ 546.1 520.7 304.8 447.3 548.9 523.5 304.8 447.3 555.2 529.8 444.5 447.3 495.3 475.0 406.4

24.50/ 23.50/ 12.00/ 20.36/ 24.36/ 23.36/ 12.00/ 20.36/ 24.61/ 23.61/ 17.50/ 20.36/ 22.20/ 21.20/ 17.50/
250-400 W ➋ 522.3 596.9 304.8 507.1 618.7 507.1 304.8 507.1 625.1 599.7 444.5 507.1 563.9 538.5 444.5

Fixture and Accessory Weights lbs/kgs


Fixture Size Fixture Weight Reflector Weight Guard Weight
50 W through 175 W 32/14.5 3/1.4 1/.5
250 W PSMH/MH 37/16.9 3/1.4 1/.5
250 W HPS 40/18.1 3/1.4 2/.9
320 W, 350 W and 400 W PSMH, 400 W MH 45/20.4 3/1.4 2/.9
Mounting Hood Weights lbs/kgs
Pendant Ceiling Bracket Stanchion
2/0.9 4/1.8 6/2.7 2/0.9
Reflector Dimensions in In/mm
Standard and Deep Dome 30° Angle High Bay
10.96"/
10.56"/ 278.4 mm
268.2 mm

5.00"/
337.8 mm

127 mm
13.30"/

9.75"/
247.7 mm

16.16"/
410.5 mm

20.80"/
528.3 mm

➊ 50, 70, 100 and 150 W HPS; 175 W PSMH; 175 and 250 W MH.
➋ 250 and 400 W HPS; 250, 320, 350 and 400 W PSMH; 400 W MH.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1225


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 100-
watt clear HPS lamp (9,500 lumens). For
candlepower values of fixtures with other
lamps, use the following multipliers: 50 W HPS
– 0.42 (4,000 lumens); 70 W HPS – 0.61 (6,300
lumens); and 150 W HPS – 1.68 (16,000 lumens).

Total Luminaire Efficiency = 76.4%


CIE Type - Semi-Direct REPORT NUMBER: CL10G
Spacing Lamps: 100 W High Pressure Sodium with Globe only
Plane Criteria
0-180 2.66 Coefficients of Utilization - Zonal Cavity Method
90-270 2.66 Effective Floor Cavity Reflectance 0.20
Diagonal 2.84 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 84 84 84 84 79 79 79 79 70 70 70 61 61 61 53 53 53 49
0-10 29.80 1 72 66 61 56 66 61 57 52 53 49 46 45 42 40 38 36 34 30
10-20 106.54 2 63 54 47 41 58 51 44 39 43 38 34 37 32 29 30 27 24 21
20-30 202.92 3 56 46 38 32 52 43 36 30 36 31 26 31 26 22 25 22 18 15
30-40 318.52 4 51 40 32 26 47 37 30 24 31 25 21 26 22 18 22 18 14 12
40-50 468.31 5 46 35 27 21 42 32 25 20 28 22 17 23 18 14 19 15 12 9
50-60 670.49 6 42 31 23 18 39 29 22 17 24 19 14 21 16 12 17 13 10 7
Lighting

60-70 866.67 7 39 28 20 15 36 26 19 14 22 16 12 18 14 10 15 11 8 6
70-80 976.61 8 36 25 18 13 33 23 17 12 20 14 10 17 12 9 14 10 7 5
80-90 1038.41 9 33 23 16 11 31 21 15 11 18 13 9 15 11 8 13 9 6 4
90-100 1042.18 10 31 21 14 10 29 19 13 9 17 12 8 14 10 7 12 8 6 4
100-110 927.00
110-120 551.82 Zonal Lumen Summary
120-130 51.82 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
Lighting: Explosionproof — Area — HID

130-140 2.51 0-30 339.26 3.6 4.7 90-120 2521.83 26.5 34.8
140-150 0.25 0-40 657.79 6.9 9.1 90-130 2572.83 27.1 35.5
150-160 0.00 0-60 1796.59 18.9 24.8 90-150 2575.59 27.1 35.5
160-170 0.00 0-90 4678.28 49.2 64.5 90-180 2575.59 27.1 35.5
170-180 0.00 0-180 7253.87 76.4 100.0

Total Luminaire Efficiency = 71.3%


CIE Type - Direct REPORT NUMBER: CL10ST
Spacing Lamps: 100 W High Pressure Sodium with Standard Dome Reflector
Plane Criteria
0-180 1.54 Coefficients of Utilization - Zonal Cavity Method
90-270 1.54 Effective Floor Cavity Reflectance 0.20
Diagonal 1.66 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 85 85 85 85 83 83 83 83 79 79 79 76 76 76 73 73 73 71
0-10 40.00 1 76 71 68 64 74 70 66 63 67 64 61 64 61 59 61 59 57 56
10-20 331.02 2 67 60 54 49 65 59 53 49 56 51 47 54 50 46 51 48 45 43
20-30 660.22 3 60 51 44 39 58 50 44 38 48 42 38 46 41 37 44 40 36 34
30-40 934.51 4 54 44 37 31 52 43 36 31 41 35 31 40 34 30 38 33 30 28
40-50 1131.33 5 49 39 31 26 48 38 31 26 36 30 25 35 29 25 33 29 25 23
50-60 1272.76 6 45 34 27 22 43 33 27 22 32 26 21 31 25 21 30 25 21 19
60-70 1322.68 7 41 30 23 19 40 30 23 18 29 23 18 28 22 18 27 22 18 16
70-80 826.95 8 38 27 21 16 37 27 20 16 26 20 16 25 20 16 24 19 16 14
80-90 254.44 9 35 25 18 14 34 24 18 14 24 18 14 23 18 14 22 17 14 12
90-100 0.00 10 33 23 17 12 32 22 16 12 22 16 12 21 16 12 20 15 12 11
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 1031.23 10.9 15.2 90-120 0.00 0.0 0.0
140-150 0.00 0-40 1965.74 20.7 29.0 90-130 0.00 0.0 0.0
150-160 0.00 0-60 4369.83 46.0 64.5 90-150 0.00 0.0 0.0
160-170 0.00 0-90 6773.90 71.3 100.0 90-180 0.00 0.0 0.0
170-180 0.00 0-180 6773.90 71.3 100.0

1226 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 100-watt (16,000 lumens).
clear High Pressure Sodium lamp (9,500
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
50 W HPS – 0.42 (4,000 lumens); 70 W HPS
– 0.61 (6,300 lumens); and 150 W HPS – 1.68

Total Luminaire Efficiency = 61.9%


CIE Type - Direct REPORT NUMBER: CL10AN
Spacing Lamps: 100 W High Pressure Sodium with 30° Angle Dome Reflector
Plane Criteria
0-180 1.96 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.50 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 74 74 74 74 72 72 72 72 69 69 69 66 66 66 63 63 63 62
0-10 34.59 1 64 60 56 53 62 59 55 52 56 53 50 53 51 49 51 49 47 46
10-20 289.50 2 57 51 45 41 55 49 44 40 47 43 39 45 41 38 43 40 37 36
20-30 587.71 3 51 43 37 32 50 42 37 32 40 35 31 38 34 31 37 33 30 28
30-40 825.38 4 47 38 31 26 45 37 31 26 35 30 26 34 29 25 32 28 25 23
40-50 944.04 5 42 33 27 22 41 32 26 22 31 26 21 30 25 21 28 24 21 19
50-60 952.84 6 39 29 23 19 38 29 23 18 28 22 18 26 22 18 25 21 18 16

Lighting
60-70 900.69 7 36 26 20 16 35 26 20 16 25 20 16 24 19 16 23 19 15 14
70-80 740.88 8 33 24 18 14 32 23 18 14 22 17 14 22 17 14 21 17 13 12
80-90 607.55 9 31 22 16 12 30 21 16 12 20 15 12 20 15 12 19 15 12 11
90-100 0.00 10 29 20 14 11 28 19 14 11 19 14 11 18 14 11 18 13 11 9
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

Lighting: Explosionproof — Area — HID


130-140 0.00 0-30 911.80 9.6 15.5 90-120 0.0 0.0 0.0
140-150 0.00 0-40 1737.18 18.3 29.5 90-130 0.0 0.0 0.0
150-160 0.00 0-60 3634.06 38.3 61.8 90-150 0.0 0.0 0.0
160-170 0.00 0-90 5883.18 61.9 100.0 90-180 0.0 0.0 0.0
170-180 0.00 0-180 5883.18 61.9 100.0

Total Luminaire Efficiency = 37.8%


CIE Type - Direct REPORT NUMBER: CL10DD
Spacing Lamps: 100 W High Pressure Sodium with Deep Dome Reflector
Plane Criteria
0-180 1.36 Coefficients of Utilization - Zonal Cavity Method
90-270 1.36 Effective Floor Cavity Reflectance 0.20
Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 45 45 45 45 44 44 44 44 42 42 42 40 40 40 39 39 39 38
0-10 26.07 1 41 39 37 35 40 38 36 35 36 35 34 35 34 33 33 32 32 31
10-20 224.04 2 37 33 30 28 36 32 30 28 31 29 27 30 28 26 29 27 26 25
20-30 437.71 3 33 29 25 22 32 28 25 22 27 24 22 26 23 21 25 23 21 20
30-40 551.18 4 30 25 21 18 29 24 21 18 23 20 18 22 20 18 22 19 18 17
40-50 656.83 5 27 22 18 15 26 21 18 15 21 17 15 20 17 15 19 17 15 14
50-60 743.35 6 25 19 16 13 24 19 16 13 18 15 13 18 15 13 17 15 13 12
60-70 592.81 7 23 17 14 11 22 17 14 11 16 13 11 16 13 11 15 13 11 10
70-80 265.53 8 21 16 12 10 21 15 12 10 15 12 10 14 12 10 14 11 10 9
80-90 94.52 9 20 14 11 9 19 14 11 9 13 11 9 13 10 8 13 10 8 8
90-100 0.00 10 18 13 10 8 18 13 10 8 12 10 8 12 9 8 12 9 7 7
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 687.82 7.2 19.1 90-120 0.0 0.0 0.0
140-150 0.00 0-40 1239.00 13.0 34.5 90-130 0.0 0.0 0.0
150-160 0.00 0-60 2639.18 27.8 73.5 90-150 0.0 0.0 0.0
160-170 0.00 0-90 3592.04 37.8 100.0 90-180 0.0 0.0 0.0
170-180 0.00 0-180 3592.04 37.8 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1227


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).

Total Luminaire Efficiency = 81.9%


REPORT NUMBER: CP40G
CIE Type - General Diffuse
Lamps: 400 W Pulse Start Metal Halide with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 89 89 89 89 83 83 83 83 72 72 72 61 61 61 52 52 52 47
0-10 161.29 1 76 70 65 60 70 65 60 56 55 51 48 46 43 40 38 35 33 29
10-20 470.38 2 67 59 51 45 62 54 48 42 45 40 36 37 33 30 30 27 24 20
20-30 918.96 3 60 50 42 36 55 46 39 33 39 33 28 32 27 23 25 22 19 15
30-40 1511.24 4 55 43 35 29 50 40 32 27 33 27 23 27 22 19 22 18 15 12
40-50 2242.10 5 50 38 30 24 45 35 28 22 29 23 19 24 19 15 19 15 12 9
50-60 3052.29 6 45 34 26 20 41 31 24 18 26 20 16 21 16 13 17 13 10 8
60-70 3653.41 7 42 30 22 17 38 28 21 16 23 18 13 19 14 11 15 11 9 6
Lighting

70-80 4255.87 8 39 27 20 15 35 25 18 14 21 15 12 17 13 9 14 10 7 5
80-90 4603.15 9 36 25 18 13 33 23 16 12 19 14 10 16 11 8 13 9 6 5
90-100 4476.83 10 33 22 16 11 31 21 15 10 18 12 9 15 10 7 12 8 6 4
100-110 4007.91
110-120 3380.83 Zonal Lumen Summary
120-130 2599.55 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 672.85 0-30 1550.63 3.5 4.3 90-120 11865.57 27.0 32.9
Lighting: Explosionproof — Area — HID

140-150 18.11 0-40 3061.87 7.0 8.5 90-130 14465.12 32.9 40.1
150-160 2.59 0-60 8356.25 19.0 23.2 90-150 15156.08 34.4 40.1
160-170 1.21 0-90 20868.68 47.4 57.9 90-180 15160.53 34.5 42.1
170-180 0.65 0-180 36029.22 81.9 100.0

Total Luminaire Efficiency = 70.4%


CIE Type - Direct REPORT NUMBER: CP40ST
Spacing Lamps: 400 W Pulse Start Metal Halide with Standard Dome Reflector
Plane Criteria
0-180 1.46 Coefficients of Utilization - Zonal Cavity Method
90-270 1.46 Effective Floor Cavity Reflectance 0.20
Diagonal 1.70 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 84 84 84 84 82 82 82 82 78 78 78 75 75 75 72 72 72 70
0-10 595.04 1 74 69 65 62 72 68 64 60 64 61 58 62 59 57 59 57 55 53
10-20 1709.44 2 65 58 52 47 63 57 51 46 54 49 45 51 47 44 49 46 43 41
20-30 2776.90 3 58 49 42 37 57 48 42 36 46 40 36 44 39 35 42 38 34 32
30-40 3730.18 4 53 43 35 30 51 42 35 30 40 34 29 38 33 29 36 32 28 26
40-50 4573.20 5 48 38 30 25 46 37 30 25 35 29 24 34 28 24 32 27 24 22
50-60 5290.95 6 44 33 26 21 43 33 26 21 31 25 21 30 25 21 29 24 20 19
60-70 5418.07 7 41 30 23 18 39 29 23 18 28 22 18 27 22 18 26 21 18 16
70-80 5086.12 8 38 27 21 16 37 27 20 16 26 20 16 25 19 16 24 19 15 14
80-90 1757.09 9 35 25 18 14 34 24 18 14 23 18 14 23 18 14 22 17 14 12
90-100 33.71 10 33 23 17 13 32 22 17 13 22 16 13 21 16 12 20 16 12 11
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 5081.38 11.5 16.4 90-120 33.71 0.1 0.1
140-150 0.00 0-40 8811.56 20.0 28.5 90-130 33.71 0.1 0.1
150-160 0.00 0-60 18675.71 42.4 60.3 90-150 33.71 0.1 0.1
160-170 0.00 0-90 30936.99 70.3 99.9 90-180 33.71 0.1 0.1
170-180 0.00 0-180 30970.7 70.4 100.0

1228 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).

Total Luminaire Efficiency = 62.5%


CIE Type - Direct REPORT NUMBER: CP40AN
Spacing Lamps: 400 W Pulse Start Metal Halide with 30° Angle Dome Reflector
Plane Criteria
0-180 2.02 Coefficients of Utilization - Zonal Cavity Method
90-270 1.48 Effective Floor Cavity Reflectance 0.20
Diagonal 1.64 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 73 73 73 73 71 71 71 71 67 67 67 63 63 63 59 59 59 58
0-10 503.08 1 64 60 56 53 62 58 55 52 54 52 49 51 49 47 48 46 44 42
10-20 1461.14 2 57 51 45 41 55 49 44 40 46 42 38 43 40 37 40 38 35 33
20-30 2434.06 3 51 44 38 33 49 42 37 32 39 35 31 37 33 30 35 31 26 27
30-40 3353.43 4 47 38 32 27 45 37 31 26 35 29 25 32 28 25 30 27 24 22
40-50 3867.50 5 43 34 27 23 41 33 27 22 31 25 22 29 24 21 27 23 20 19

Lighting
50-60 3954.40 6 39 30 24 19 38 29 23 19 27 22 18 26 21 18 24 20 17 16
60-70 3752.38 7 36 27 21 17 35 26 21 17 25 20 16 23 19 16 22 18 15 14
70-80 3368.71 8 34 24 19 15 32 24 18 15 22 18 14 21 17 14 20 16 13 12
80-90 2643.39 9 31 22 17 13 30 22 16 13 21 16 13 20 15 12 19 15 12 11
90-100 1531.50 10 29 20 15 12 28 20 15 12 19 14 11 18 14 11 17 13 11 10
100-110 421.63
110-120 86.74 Zonal Lumen Summary
120-130 65.68 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

Lighting: Explosionproof — Area — HID


130-140 20.81 0-30 4398.28 10.0 16.0 90-120 2039.87 4.6 7.4
140-150 11.94 0-40 7751.71 17.6 28.2 90-130 2105.55 4.8 7.7
150-160 7.93 0-60 15573.61 35.4 56.7 90-150 2138.30 4.9 7.7
160-170 4.46 0-90 25338.08 57.6 92.2 90-180 2152.16 4.9 7.8
170-180 1.47 0-180 27490.24 62.5 100.0

Total Luminaire Efficiency = 69.1%


CIE Type - Direct REPORT NUMBER: CP40DD
Spacing Lamps: 400 W Pulse Start Metal Halide with Deep Dome Reflector
Plane Criteria
0-180 1.48 Coefficients of Utilization - Zonal Cavity Method
90-270 1.48 Effective Floor Cavity Reflectance 0.20
Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 82 82 82 82 80 80 80 80 77 77 77 73 73 73 70 70 70 69
0-10 676.92 1 74 70 66 63 72 68 65 62 65 63 60 63 60 58 60 58 57 55
10-20 1962.51 2 66 59 54 49 64 58 53 49 55 51 47 53 49 46 51 48 45 44
20-30 3199.12 3 59 51 44 39 57 50 44 39 48 42 38 46 41 38 44 40 37 35
30-40 4281.42 4 54 44 38 32 52 43 37 32 42 36 32 40 35 31 38 34 31 29
40-50 4889.12 5 49 39 32 27 47 38 32 27 37 31 27 35 30 26 34 29 26 24
50-60 5408.09 6 45 35 28 23 44 34 28 23 33 27 23 32 26 23 30 26 22 21
60-70 5456.18 7 41 31 24 20 40 31 24 20 30 24 20 29 23 20 28 23 19 18
70-80 3822.90 8 38 28 22 18 37 28 22 18 27 21 17 26 21 17 25 21 17 16
80-90 693.25 9 36 26 20 16 35 25 20 16 25 19 16 24 19 15 23 19 15 14
90-100 20.14 10 34 24 18 14 33 23 18 14 23 18 14 22 17 14 21 17 14 12
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 5838.56 13.3 19.2 90-120 20.14 0.0 0.1
140-150 0.00 0-40 10119.98 23.0 33.3 90-130 20.14 0.0 0.1
150-160 0.00 0-60 20417.19 46.4 67.1 90-150 20.14 0.0 0.1
160-170 0.00 0-90 30389.51 69.1 99.9 90-180 20.14 0.0 0.1
170-180 0.00 0-180 30409.65 69.1 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1229


© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).

Total Luminaire Efficiency = 63.4%


CIE Type - Direct REPORT NUMBER: CP40HB
Spacing Lamps: 400 W Pulse Start Metal Halide with High Bay Reflector
Plane Criteria
0-180 1.40 Coefficients of Utilization - Zonal Cavity Method
90-270 1.40 Effective Floor Cavity Reflectance 0.20
Diagonal 1.52 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 76 76 76 76 74 74 74 74 70 70 70 67 67 67 65 65 65 63
0-10 1044.42 1 71 69 67 65 69 67 65 64 65 63 62 62 61 60 60 59 58 57
10-20 3491.70 2 66 62 59 56 64 61 58 55 59 56 54 57 55 53 55 53 52 50
20-30 5976.88 3 61 56 52 48 60 55 51 48 53 50 47 51 49 46 50 48 46 44
Lighting

30-40 6632.58 4 57 50 46 42 55 50 45 42 48 44 42 47 44 41 45 43 40 39
40-50 7143.25 5 53 46 41 37 51 45 40 37 44 40 37 43 39 36 42 38 36 35
50-60 2844.46 6 49 42 37 33 48 41 36 33 40 36 33 39 35 32 38 35 32 31
60-70 634.65 7 46 38 33 30 44 37 33 29 37 32 29 36 32 29 35 31 29 28
70-80 115.54 8 42 35 30 27 42 34 30 26 34 29 26 33 29 26 32 29 26 25
80-90 20.82 9 40 32 27 24 39 32 27 24 31 27 24 30 26 24 30 26 24 23
Lighting: Explosionproof — Area — HID

90-100 1.23 10 37 29 25 22 36 29 25 22 29 24 22 28 24 22 27 24 21 20
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 10513.00 23.9 37.7 90-120 1.23 0.0 0.0
140-150 0.00 0-40 17145.58 39.0 61.4 90-130 1.23 0.0 0.0
150-160 0.00 0-60 27133.29 61.7 97.2 90-150 1.23 0.0 0.0
160-170 0.00 0-90 27904.30 63.4 100.0 90-180 1.23 0.0 0.0
170-180 0.00 0-180 27905.53 63.4 100.0

1230 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Induction Lighting System
Explosionproof, Factory Sealed

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Applications
• Ideal for where access to relamp is difficult, reliability is
essential and environment is costly to maintain. Also for
cold-environment applications.
• Code Master Induction fixtures are ideal for: use in chemical
and petrochemical plants, such as manufacturers of plastics,
paints and thinners; in refineries; and in other process areas
where ignitable vapors, moisture and corrosive elements
may be present.
• Suitable for use in wet locations.
Features
• Instant start and restrike.
• High lumen output and efficacy (up to 73 lumens per watt).
• Fixtures operate safely in a 104 °F/40 °C ambient.
• Good lumen maintenance provides less than 30% depreciation
after 60,000 hours of operation.
• Virtually maintenance free.
• Ultra-long 100,000 hours of life keeps maintenance costs Illustrated Features
to a minimum.
• Starts in temperatures as low as -40 °F/-40 °C.
• Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
• Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. Only wiring
required is attaching two wires to connection block in
mounting hood.
• Connection block is easily wired: (a) loosen two screws; (b)

Lighting
make wire connections; and (c) reposition connection block
and tighten screws.
• Low total harmonic distortion (<10%).
• No cycling at end of life.
• Acme double lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered

Lighting: Explosionproof — Area — Induction


with single lead threads during fixture unit removal.
• All threaded joints are flame-tight.
• Factory sealed. External seals not required.
• Strategic location of lamp socket in combination with the
interior prism design of the glass globe, provides optimum light
distribution and control.
• Superior corrosion resistance, with epoxy powder coat finish.
• Choice of mountings: pendant, ceiling, bracket or stanchion.
• Fiberglass-reinforced polyester reflectors, in standard
Standard Finishes
dome, deep dome or 30° angle, are ideal in installations • Fixture bodies, guards and mounting hoods: epoxy powder
where luminaire is subject to exceptionally severe corrosive coat finish, electrostatically applied for complete, uniform
atmospheres. The high bay aluminum reflector is designed corrosion protection.
for installations where mounting height work planes range Options
from 20 to 30 feet/6 to 9 meters
• Fuses can be ordered for field installation by catalog number.
• Optional guards protect globes from damage. Secured to
fixture with three screws. Certifications and Compliances
Standard Materials • UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10444
• Fixture bodies and guards: copperfree (4/10 of 1% max.)
aluminum.
• Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum.
• Ceiling, bracket and stanchion mounting hoods: sand-cast
copperfree (4/10 of 1% max.) aluminum.
• Reflectors: aluminum or fiberglass reinforced polyester.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1231


© September 2010
Code•Master 2™ Induction Lighting System Classified Area and Ambient Suitability
Explosionproof, Factory Sealed

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Classified Area Suitability of Code•Master 2 Series Induction Fixtures (suitability includes use of reflector)
Class I, Division 1 & 2 Class II, Division 1 & 2
With Globe or with Globe & Reflector With Globe or with Globe & Reflector
Lamps Supply Wire Ambient NEC/cUL/CEC Temp. Ident. No. NEC/cUL/CEC Temp. Ident. No.
Temp Temp
Type Watts °F/°C °F/°C Nameplate Marking Groups Nameplate Marking Groups
55 140/60 104/40 T6 C,D T6 E,F,G
Induction
85 167/75 104/40 T6 C,D T6 E,F,G
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the
National Electrical Code.

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.

“T”
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Number

Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(°F)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101-
Lighting

Range 86-100 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120
(°˚C)
Lighting: Explosionproof — Area — Induction

1232 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Induction Lighting System
Explosionproof, Factory Sealed
55 W and 85 W

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Type Lamp Hub Size Catalog


Mounting Watts (Inches) Number ➊
Pendant
One Hub, 55 3/4 CQP5575 ➋
Rigid or Flexible
55 1 CQP5510 ➋
Mounting
85 3/4 CQP8575 ➋
85 1 CQP8510 ➋

Ceiling
Four Hubs, 55 3/4 CQC5575 ➋
Three Close-up Plugs
55 1 CQC5510 ➋
85 3/4 CQC8575 ➋
85 1 CQC8510 ➋

Lighting
Bracket
Four Hubs, 55 3/4 CQB5575 ➋
Three Close-up Plugs
55 1 CQB5510 ➋
85 3/4 CQB8575 ➋
85 1 CQB8510 ➋

Lighting: Explosionproof — Area — Induction


25° Stanchion ➍
One Hub 55 1-1/4 or 1-1/2 ➌ CQS55150 ➋

85 1-1/4 or 1-1/2 ➌ CQS85150 ➋


➊ To order fixture with guard, add suffix G (before adding voltage suffix).
➋ Add voltage suffix 120 for 90-140 Vac; or 277 for 180-305 Vac.
➌ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➍ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
Shaded items are suitable for Class I, Group C in addition to other applicable area suitabilities.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1233


© September 2010
Code•Master 2™ Induction Lighting System Accessories
Explosionproof, Factory Sealed

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Mounting Hoods
Hub Size
Type Mounting (Inches) Catalog Number
Pendant
One Hub 3/4 CAP-75
1 CAP-100

Ceiling
Four Hubs, 3/4 CAC-75
Three Close-Up Plugs
1 CAC-100

Bracket
Four Hubs, 3/4 CALB-75
Three Close-Up Plugs
1 CALB-100

25˚ Stanchion
One Hub 1-1/4 or 1-1/2 ➊ CAS-150
Lighting

Mounting Adapter with Connection Block

Permits use of existing A-51 mounting hoods (AAC Ceiling or AALB


Bracket) with the new Code•Master 2 Fixture Unit. After removing
existing Fixture Unit and adapter, screw in the new CMAD-1 Adapter.
Then thread new Fixture Unit into the CMAD-1. CMAD-1
Lighting: Explosionproof — Area — Induction

Fixture Units — 55 W to 85 W
Fixture body with globe. Indicate voltage desired by adding voltage suffix to Fixture Unit catalog
number listed below.
Add Voltage Suffixes
Lamp Fixture Unit
Type Frequency Watts Number 120 V 277 V
Induction 50/60 Hz 55 CMBQ55 -12 -27
50/60 Hz 85 CMBQ85 -12 -27

Fixture and Accessory Weights lbs/kgs Mounting Hood Weights lbs/kgs


Reflector Guard
Fixture Size Fixture Weight Weight Weight Pendant Ceiling Bracket Stanchion
55 W 28/12.7 3/1.4 1/.5 2/.9 4/1.8 6/2.7 2/.9
85 W 28/12.7 3/1.4 1/.5

➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.


Shaded items are suitable for Class I, Group C in addition to other applicable area suitabilities.

1234 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Induction Lighting System Accessories
Explosionproof, Factory Sealed

Description Catalog Number


Polyester Reflectors — 55 W and 85 W
Standard Dome CMR-4ST
Deep Dome CMR-4DD
30˚ Angle CMR-4AN

Aluminum High Bay Reflectors


55 W and 85 W CMR-4HB

Prismatic Glass Globes


55 W and 85 W CGL-400

Lighting
Aluminum Guards
CGU4

Lighting: Explosionproof — Area — Induction


Connection Block
55 W and 85 W VPT-7
For all Code•Master 2 Induction fixtures

Lamp
Watts Volts Fuse Quantity Required Fuse Catalog Number
55 120-277 See note below ➊ CF2
85 120-277 See note below ➊ CF2

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw.
➊ Order one fuse for 120 and 277 V, and 2 fuses for 208 and 240 V.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1235


© September 2010
Code•Master 2™ Induction Lighting System Operating Data
Explosionproof, Factory Sealed

Electromagnetic Compatibility
A.) Complies with European norms EN55015, EN6100-3-2 and EN61547
B.) RFI
a.) Meets standard EN55022 and is valid for frequencies up to 1000 MHz.

Electrical Characteristics
55 W 55 W 85 W 85 W
100-120 V 200-277 V 100-120 V 200-277 V
System power ➊ nom. W 55 55 85 85
System power ➊ min. W 53.1 53.1 82.0 82.0
System power ➊ max. W 56.9 56.9 88.0 88.0
AC supply voltage nom. V 120 230 120 230
AC supply voltage min. V 90 180 90 180
AC supply voltage max. V 140 305 140 305
DC supply voltage nom. V 120 230 120 230
DC supply voltage min. V 90 180 90 180
DC supply voltage max. V 180 350 180 350
Supply frequency nom. Hz 60 50 60 50
Supply frequency min. Hz 47 47 47 47
Supply frequency max. Hz 63 63 63 63
Supply current nom. mA 460 260 730 400
Inrush current max. A 16 12 16 12
Duration inrush current max. usec 170 170 170 170
Lighting

Power factor nom. >0.92 >0.92 >0.92 >0.92


HF output frequency nom. MHz 2.65 2.65 2.65 2.65
HF output frequency min. MHz 2.30 2.30 2.30 2.30
HF output frequency max. MHz 3.00 3.00 3.00 3.00
HF output voltage max. kV 1.5 1.5 1.5 1.5
Leakage current mA <0.5 <0.5 <0.5 <0.5
Overvoltage 200 Vac 400 Vac 200 Vac 400 Vac
Lighting: Explosionproof — Area — Induction

Lamp Characteristics

Values at 100 hours QL 55 W QL 85 W


Luminous flux nom. lm 3500 6000
Luminous flux min. lm 3200 5500
Luminous flux max. lm 3800 6500
System efficacy nom. lm/W 65 70

Lamp Operation
A.) Ignition and Lifetime Performance
a.) Ignition time <0.5 second
Hot Restrike time <0.5 second
b.) Induction lighting offers a direct, flicker-free ignition after switch-on, in both cold and hot conditions
B.) Lumen Maintenance
a.)The lumens of an induction lamp are expected to have depreciated after 60,000 hours to no less than 75% of the initial lumens

➊ At design voltage.

1236 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Induction Lighting System Photometric Data
Explosionproof, Factory Sealed

Data based on fixtures with 85-watt lamp.


For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).

Total Luminaire Efficiency = 71.6%


Report Number: CMBQL85
CIE Type - Semi-Direct
85-Watt Lamp with Globe only
Degree Candela Lumens Coefficients of Utilization - Zonal Cavity Method
0 301 Effective Floor Cavity Reflectance (Rfc) = 0.20
5 304 29 % Ceiling Rc 80 70 50 30 10 0
15 318 91 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
25 359 166 0 79 79 79 79 74 74 74 74 65 65 65 57 57 57 49 49 49 46
35 398 250 1 68 63 58 54 63 59 55 51 51 48 45 44 41 39 37 35 33 30
45 424 328 2 60 53 46 41 56 49 43 39 42 38 34 36 32 29 30 27 25 22
55 447 400 3 54 45 38 32 50 42 36 30 36 31 27 30 26 23 25 22 19 16
65 465 462 4 49 39 32 26 45 36 30 25 31 26 22 26 22 19 22 18 16 13
75 475 502 5 45 34 27 22 41 32 25 21 27 22 18 23 19 15 19 16 13 11
85 474 517 6 41 30 23 19 38 28 22 17 24 19 15 21 16 13 17 14 11 9
90 472 Zonal Lumen Summary 7 38 27 21 16 35 25 19 15 22 17 13 19 14 11 16 12 9 7
95 468 510 Zone Lumens % Lamp % Fixture 8 35 25 18 14 32 23 17 13 20 15 11 17 13 10 14 11 8 6
105 440 464 0- 30 287 4.8 6.7 9 32 22 16 12 30 21 15 11 18 13 10 15 11 9 13 10 7 6
115 348 344 0- 40 537 8.9 12.5 10 30 20 15 11 28 19 14 10 17 12 9 14 10 8 12 9 6 5
125 205 185 0- 60 1265 21.1 29.4
135 58 49 0- 90 2745 45.7 63.9
145 2 2 90-120 1318 22.0 30.6
155 1 0 90-130 1503 25.0 35.0

Lighting
165 1 0 90-150 1553 25.9 36.1
175 0 0 90-180 1553 25.9 36.1
180 0 0-180 4298 71.6 100.0

Total Luminaire Efficiency = 62.9%


Report Number: CMBQL85ST
CIE Type - Direct
85-Watt Lamp with Standard Dome Reflector

Lighting: Explosionproof — Area — Induction


Degree Candela Lumens Coefficients of Utilization - Zonal Cavity Method
0 960 Effective Floor Cavity Reflectance (Rfc) = 0.20
5 962 92 % Ceiling Rc 80 70 50 30 10 0
15 955 271 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
25 942 436 0 75 75 75 75 73 73 73 73 69 69 69 66 66 66 63 63 63 62
35 903 566 1 67 64 61 58 66 63 60 57 60 58 55 57 55 54 55 53 52 50
45 834 647 2 61 55 50 46 59 54 49 46 51 48 44 49 46 43 47 44 42 41
55 764 683 3 55 48 42 38 53 46 41 37 44 40 36 43 39 36 41 38 35 33
65 611 600 4 50 42 36 31 48 41 35 31 39 34 30 37 33 30 36 32 29 28
75 325 346 5 45 37 31 26 44 36 30 26 35 30 26 33 29 25 32 28 25 24
85 76 89 6 42 33 27 23 40 32 27 22 31 26 22 30 25 22 29 25 22 20
90 14 Zonal Lumen Summary 7 39 30 24 20 37 29 23 20 28 23 19 27 22 19 26 22 19 18
95 10 11 Zone Lumens % Lamp % Fixture 8 36 27 21 17 35 26 21 17 25 21 17 25 20 17 24 20 17 15
105 8 10 0-30 798 13.3 21.1 9 33 25 19 15 32 24 19 15 23 19 15 23 18 15 22 18 15 14
115 11 10 0-40 1364 22.7 36.1 10 31 23 17 14 30 22 17 14 21 17 14 21 17 14 20 16 13 12
125 11 9 0-60 2694 44.9 71.4
135 6 5 0-90 3729 62.2 98.8
145 1 1 90-120 31 0.5 0.8
155 1 0 90-130 40 0.7 1.1
165 0 0 90-150 46 0.8 1.2
175 1 0 90-180 46 0.8 1.2
180 0 0-180 3775 62.9 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1237


© September 2010
Code•Master 2™ Induction Lighting System Photometric Data
Explosionproof, Factory Sealed

Data based on fixtures with 85-watt lamp.


For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).

Total Luminaire Efficiency = 56.7%


Report Number: CMBQL85AN
CIE Type - Direct 85-Watt Lamp with 30° Angle Dome Polyester Reflector
Candela Distribution Coefficients of Utilization - Zonal Cavity Method

0.0 45.0 90.0 135.0 180.0 Flux Effective Floor Cavity Reflectance (Rfc) = 0.20

0 842 842 842 842 842 % Ceiling Rc 80 70 50 30 10 0

5 881 869 843 814 802 81 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

15 956 920 835 764 738 239 0 67 67 67 67 65 65 65 65 61 61 61 58 58 58 55 55 55 54

25 1015 956 833 728 676 388 1 60 56 53 51 58 55 52 49 52 49 47 49 47 45 46 45 43 42

35 1044 969 822 612 473 494 2 54 48 44 40 52 47 43 39 44 41 38 42 39 37 40 37 35 34

45 1046 960 772 358 198 522 3 48 42 37 33 47 41 36 32 38 34 31 36 33 30 35 32 29 28

55 1030 945 595 137 52 498 4 44 37 31 27 43 36 31 27 34 30 26 32 28 25 31 27 25 23

65 1004 898 349 30 3 441 5 40 33 27 23 39 32 27 23 30 26 22 29 25 22 27 24 21 20

75 932 711 142 2 0 349 6 37 29 24 20 36 29 23 20 27 23 19 26 22 19 25 21 19 17

85 705 425 43 1 1 223 7 34 26 21 17 33 26 21 17 25 20 17 24 20 17 23 19 16 15

90 551 289 11 2 2 8 32 24 19 15 31 23 19 15 22 18 15 22 18 15 21 17 15 13

95 393 177 4 4 4 108 9 30 22 17 14 29 21 17 14 21 16 13 20 16 13 19 16 13 12

105 147 61 1 9 6 40 10 28 20 16 12 27 20 15 12 19 15 12 18 15 12 18 14 12 11
Lighting

115 46 4 3 13 9 13 Zonal Lumen Summary

125 2 1 4 12 9 5 Zone Lumens % Lamp % Fixture


135 0 1 2 4 3 2 0- 30 707 11.8 20.8
145 0 1 1 1 1 1 0- 40 1201 20.0 35.3
155 0 1 2 2 1 1 0- 60 2221 37.0 65.3
165 0 1 1 1 0 0 0- 90 3233 53.9 95.0
Lighting: Explosionproof — Area — Induction

175 1 1 1 1 0 0 90-120 160 2.7 4.7


180 1 1 1 1 1 90-130 165 2.8 4.9
90-150 168 2.8 4.9
90-180 169 2.8 5.0
0-180 3403 56.7 100.0

1238 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Induction Lighting System Photometric Data

Data based on fixtures with 85-watt lamp.


For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).

Total Luminaire Efficiency = 63.4%


Report Number: CMBQL85DD
CIE Type - Direct
85-Watt Lamp with Deep Dome Polyester Reflector
Degree Candela Lumens Coefficients of Utilization - Zonal Cavity Method
0 1110 Effective Floor Cavity Reflectance (Rfc) = 0.20
5 1109 106 % Ceiling Rc 80 70 50 30 10 0
15 1108 313 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
25 1073 495 0 75 75 75 75 74 74 74 74 70 70 70 67 67 67 64 64 64 63
35 990 620 1 69 66 63 60 67 64 62 59 61 59 57 59 57 55 56 55 54 52
45 877 679 2 62 57 52 49 60 56 52 48 53 50 47 51 48 46 49 47 45 43
55 788 700 3 56 50 44 40 55 48 44 40 46 42 39 45 41 38 43 40 37 36
65 562 552 4 51 44 38 33 50 43 37 33 41 36 33 39 35 32 38 34 32 30
75 226 245 5 47 39 33 28 46 38 32 28 36 32 28 35 31 28 34 30 27 26
85 48 55 6 43 35 29 25 42 34 28 24 33 28 24 32 27 24 31 27 24 22
90 12 Zonal Lumen Summary 7 40 31 26 22 39 31 25 21 30 25 21 29 24 21 28 24 21 19
95 7 8 Zone Lumens % Lamp % Fixture 8 37 28 23 19 36 28 23 19 27 22 19 26 22 19 25 21 18 17
105 7 8 0-30 915 15.2 24 9 35 26 21 17 34 26 20 17 25 20 17 24 20 17 23 19 17 15
115 10 10 0-40 1535 25.6 40.3 10 32 24 19 15 32 24 19 15 23 18 15 22 18 15 22 18 15 14
125 11 9 0-60 2914 48.6 76.5
135 6 5 0-90 3766 62.8 98.9
145 1 1 90-120 27 0.4 0.7
155 1 0 90-130 35 0.6 0.9
165 0 0 90-150 40 0.7 1.1

Lighting
175 1 0 90-180 41 0.7 1.1
180 0 0-180 3806 63.4 100.0

Total Luminaire Efficiency = 56.4%


Report Number: CMBQL85HB
CIE Type - Direct
85-Watt Lamp with High Bay Aluminum Reflector
Degree Candela Lumens Coefficients of Utilization - Zonal Cavity Method

Lighting: Explosionproof — Area — Induction


0 2608 Effective Floor Cavity Reflectance (Rfc) = 0.20
5 2578 244 % Ceiling Rc 80 70 50 30 10 0
15 2261 634 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
25 1705 784 0 67 67 67 67 65 65 65 65 62 62 62 59 59 59 57 57 57 56
35 1237 774 1 63 61 60 58 62 60 59 57 58 56 55 55 54 54 53 53 52 51
45 770 588 2 59 56 53 51 58 55 52 50 53 51 49 51 49 48 49 48 47 46
55 241 228 3 55 51 48 45 54 50 47 45 49 46 44 47 45 43 46 44 42 41
65 66 69 4 52 47 43 40 51 46 43 40 45 42 39 43 41 39 42 40 38 37
75 15 17 5 49 43 39 36 48 42 39 36 41 38 36 40 37 35 39 37 35 34
85 3 4 6 46 40 36 33 45 39 35 33 38 35 32 37 34 32 36 34 32 31
90 2 Zonal Lumen Summary 7 43 37 33 30 42 36 32 30 35 32 30 35 32 29 34 31 29 28
95 5 5 Zone Lumens % Lamp % Fixture 8 40 34 30 27 40 34 30 27 33 30 27 32 29 27 32 29 27 26
105 10 10 0- 30 1662 27.7 49.1 9 38 32 28 25 37 31 28 25 31 27 25 30 27 25 30 27 25 24
115 13 13 0- 40 2435 40.6 71.9 10 36 30 26 23 35 29 26 23 29 25 23 28 25 23 28 25 23 22
125 12 11 0- 60 3251 54.2 96.0
135 7 5 0- 90 3340 55.7 98.6
145 1 0 90-120 29 0.5 0.9
155 0 0 90-130 40 0.7 1.2
165 0 0 90-150 46 0.8 1.3
175 1 0 90-180 46 0.8 1.4
180 1 0-180 3386 56.4 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1239


© September 2010
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

NEC: CEC: V Exd IIB + H2


Class I, Division 1 and 2, Groups B, C, D Class I, Division 1 and 2, Groups B, C, D Suitable for use in wet locations
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB + H2 T6
Class III Class II, Division 1 and 2, Groups E, F, G
NEMA 4X Class III
Suitable for use in wet locations CSA 4X

Applications
• For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured, and in
other areas where ignitable vapors, dust, moisture and corrosive
elements may be present.
• For use in areas where an instant-on white light is desired.
• Suitable for use in wet locations.
• Standard fixtures designed for 26 W, 32 W, 42 W, 52 W (two 26
W), 64 W (two 32 W), and 84 W (two 42 W) PLT lamps.
• Cold weather starting to a minimum temperature of 0 °F/
-18 °C for the Code•Master Jr. PLT and -22 °F/-30 °C for the
Code•Master 2 PLT.
Features
• Fixtures operate safely in high ambient temperatures. 26-42W Code•Master Jr. PLT
Lighting: Explosionproof — Area — Fluorescent

• Arrangement of heat-producing components results in efficient


heat dissipation for cooler fixture operation.
• Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. The only
wiring required is attaching two wires to connection block
in mounting hood.
• Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
• Acme double-lead threads speed installation and fixture removal
from mounting hood – only half as many turns are required
as for single-lead threads. The threads do not stick, or gall,
eliminating problems often encountered with single-lead threads
during fixture unit removal. 52-84W Code•Master 2 PLT
• All threaded joints are flame-tight.
• Factory sealed. External seals not required for Groups C and D.
• Fixtures for use in Group B locations are furnished complete Illustrated Features
with UL required sealing fitting for Code•Master Jr. PLT only.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior. Mounting Hood
• Superior corrosion resistance, with epoxy powder coat finish.
• Fluorescent light source reduces energy cost.
• Strategic location of lamp socket, in combination with interior
Lighting

prism design of the glass globe, provides optimum light Collector Ring Connection Block
distribution and control. and Pin
• Choice of mountings – pendant, ceiling, bracket and stanchion. Double Lead
• Optional guards protect globes from damage. Secured to fixture Acme Threads
with three stainless steel screws.
• Fiberglass reinforced polyester reflectors, in standard dome
or 30° angle styles, are ideal in installations where luminaire is As Fixture unit is threaded into mounting
subject to exceptionally severe corrosive atmospheres. The hood an automatic electrical connection is made.
high bay aluminum reflector is intended for installations where
mounting height work planes range from 20 to 30 feet/6 to 9
meters. Standard Finishes
• Fluorescent lamp life of 10,000 hours reduces relamping cost • Ballast bodies, guards and mounting hoods: epoxy powder
compared to incandescent, and pr • Ballast bodies coat finish, electrostatically applied for complete, uniform
and guards: copperfree (4/10 of 1% max.) aluminum corrosion protection
• Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum
Certifications and Compliances
• Ceiling, bracket and stanchion mounting hoods: sand cast • UL Standard: UL 1598, UL 844
copperfree (4/10 of 1% max.) aluminum • UL Listed: E10444
• Reflectors: fiberglass reinforced polyester (white) or
aluminum

 Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
V CSA Certification only.

1240 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

NEC: CEC: V Exd IIB + H2


Class I, Division 1 and 2, Groups B, C, D Class I, Division 1 and 2, Groups B, C, D Suitable for use in wet locations
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB + H2 T6
Class III Class II, Division 1 and 2, Groups E, F, G
NEMA 4X Class III
Suitable for use in wet locations CSA 4X

Catalog Numbering Guide


CJ F P 26 75 G BU L

Series: Mouning: Hub Size: Voltage:


CJ - Code•Master P - Pendant 75 - 3/4” BU - 120-277 V 50/60 Hz
Jr. ◆ C - Ceiling 10 - 1” A5 - 347 V 60 Hz V
C - Code•Master 2 B - Bracket 150 - 1-1/2” or 1-1/4”
S - Stanchion
PB - Group B Pendant ◆
SB - Group B Stanchion ◆

Lamp Type: Wattage: Guard: Options:


F - Fluorescent 26 - 26 Watts G - Guard provided L - Lamps Provided

Lighting: Explosionproof — Area — Fluorescent


32 - 32 Watts Blank - Guard not provided F - Fused
42 - 42 Watts Z - Zone 1
52 - 52 Watts Exd IIB + H2 V
64 - 64 Watts
84 - 84 Watts

Classified Area Suitability of Code•Master™ Series PLT Fixtures — Suitability includes use of reflector
Class I, Division 1 & 2 with Globe or Class II, Division 1 & 2 with Globe or
with Globe & Reflector with Globe & Reflector
UL/NEC Temp. Ident. No. UL/NEC Temp. Ident. No.
Supply Ambient
Lamp Lamp Nameplate Nameplate
Wire Temp Groups Groups
Type Watts Marking Marking
°F/°C °F/°C
PLT
26 167/75 104/40 T6 B◆,C,D T4A E, F, G
(4-pin)
PLT
32 167/75 104/40 T6 B◆,C,D T4A E, F, G
(4-pin)
PLT
42 167/75 104/40 T6 B◆,C,D T4A E, F, G
(4-pin)
167/75 104/40 T6 C, D T4 E, F, G
PLT 52
167/75 131/55 T5 C, D — —
(4-pin) (2 x 26)
167/75 149/65 T5 C, D — —

Lighting
167/75 104/40 T6 C, D T4 E, F, G
PLT 64
167/75 131/55 T5 C, D — —
(4-pin) (2 x 32)
167/75 149/65 T5 C, D — —
167/75 104/40 T6 C, D T4 E, F, G
PLT 84
167/75 131/55 T5 C, D — —
(4-pin) (2 x 42)
167/75 149/65 T5 C, D — —

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Number
Temp
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(°F)
Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101-
Range 86-100 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120
(°˚C)
 Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1241


© September 2010
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations

Lamp Hub Size Catalog Number


Watts (Inches) with Globe ➊
Pendant — One Hub, Rigid or Flexible Mounting
26 3/4 CJFPB2675BU

32 3/4 CJFPB3275BU

42 3/4 CJFPB4275BU
Lighting: Explosionproof — Area — Fluorescent

25° Stanchion One Hub


26 1-1/2 CJFSB26150BU

32 1-1/2 CJFSB32150BU

42 1-1/2 CJFSB42150BU

Mounting Hoods
Hub Size Catalog
Inches Number
Pendant — One Hub

3/4 CAP-75B
Lighting

25° Stanchion — One Hub ➋

1-1/2 CAS-150B

NOTE: Fixture units are the same as listed on following pages.


 Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
➊ To order fixture with guard, add suffix -G before adding voltage suffix.
➊ To order fixture with lamp(s), add suffix -L after voltage suffix.
➋ Malleable iron sealing fittings are available in the Fittings Section.

1242 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

NEC: CEC: V Exd IIB + H2


Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Suitable for use in wet locations
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB + H2 T6
Class III Class II, Division 1 and 2, Groups E, F, G
NEMA 4X Class III
Suitable for use in wet locations CSA 4X

NEC/CEC V CEC V
Lamp Hub Size Catalog Number Catalog Number
Watts (Inches) with Globe ➊➌ with Globe ➊➌
Pendant — One Hub, Rigid or Flexible Mounting
3/4 CJFP2675BU CJFP2675A5
26 (1 x 26)
1 CJFP2610BU CJFP2610A5
3/4 CJFP3275BU CJFP3275A5
32 (1 x 32)
1 CJFP3210BU CJFP3210A5
3/4 CJFP4275BU CJFP4275A5
42 (1 x 42)
1 CJFP4210BU CJFP4210A5
3/4 CFP5275BU CFP5275A5
52 (2 x 26)
1 CFP5210BU CFP5210A5
3/4 CFP6475BU CFP6475A5
64 (2 x 32)
1 CFP6410BU CFP6410A5

Lighting: Explosionproof — Area — Fluorescent


3/4 CFP8475BU CFP8475A5
26-42 W Shown 84 (2 x 42)
1 CFP8410BU CFP8410A5
Ceiling — Four Hubs, Three Close-Up Plugs
3/4 CJFC2675BU CJFC2675A5
26 (1 x 26)
1 CJFC2610BU CJFC2610A5
3/4 CJFC3275BU CJFC3275A5
32 (1 x 32)
1 CJFC3210BU CJFC3210A5
3/4 CJFC4275BU CJFC4275A5
42 (1 x 42)
1 CJFC4210BU CJFC4210A5
3/4 CFC5275BU CFC5275A5
52 (2 x 26)
1 CFC5210BU CFC5210A5
3/4 CFC6475BU CFC6475A5
64 (2 x 32)
1 CFC6410BU CFC6410A5
3/4 CFC8475BU CFC8475A5
84 (2 x 42)
52-84 W Shown 1 CFC8410BU CFC8410A5
Bracket — Four Hubs, Three Close-Up Plugs
3/4 CJFB2675BU CJFB2675A5
26 (1 x 26)
1 CJFB2610BU CJFB2610A5
3/4 CJFB3275BU CJFB3275A5
32 (1 x 32)
1 CJFB3210BU CJFB3210A5
3/4 CJFB4275BU CJFB4275A5
42 (1 x 42)
1 CJFB4210BU CJFB4210A5

Lighting
3/4 CFB5275BU CFB5275A5
52 (2 x 26)
1 CFB5210BU CFB5210A5
3/4 CFB6475BU CFB6475A5
64 (2 x 32)
1 CFB6410BU CFB6410A5
26-42 W Shown 3/4 CFB8475BU CFB8475A5
84 (2 x 42)
1 CFB8410BU CFB8410A5
25° Stanchion — One Hub
26 (1 x 26) 1-1/4 or 1-1/2 ➋ CJFS26150BU CJFS26150A5
32 (1 x 32) 1-1/4 or 1-1/2 ➋ CJFS32150BU CJFS32150A5
42 (1 x 42) 1-1/4 or 1-1/2 ➋ CJFS42150BU CJFS42150A5
52 (2 x 26) 1-1/4 or 1-1/2 ➋ CFS52150BU CFS52150A5
64 (2 x 32) 1-1/4 or 1-1/2 ➋ CFS64150BU CFS64150A5
84 (2 x 42) 1-1/4 or 1-1/2 ➋ CFS84150BU CFS84150A5

52-84 W Shown

➊ To order fixture with guard, add suffix -G before adding voltage suffix. To order fixture with lamp(s), add suffix -L after voltage suffix.
➋ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➌ BU is 120 through 277 V, 50/60 Hz and 125 Vdc. A5 is 347 V, 60 Hz V.
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1243


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

NEC: CEC: V Exd IIB + H2


Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Suitable for use in wet locations
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB + H2 T6
Class III Class II, Division 1 and 2, Groups E, F, G
NEMA 4X Class III
Suitable for use in wet locations CSA 4X

Mounting Hoods
Hub Size Catalog
(Inches) Number
Pendant
3/4 CAP-75

1 CAP-100

Ceiling
3/4 CAC-75

1 CAC-100
Lighting: Explosionproof — Area — Fluorescent

Bracket
3/4 CALB-75

1 CALB-100

25° Stanchion

1-1/4 or 1-1/2 ➊ CAS-150 ➊

Mounting Adapter with Connection Block

CMAD-1

Fixture Units
Line Catalog
Hz
Voltage Number
Ballast body with globe
120-277 50/60 CJB26FBU ➋
120-277 50/60 CJB32FBU ➋
Lighting

120-277 50/60 CJB42FBU ➋


120-277 50/60 CMBF52BU
120-277 50/60 CMBF64BU
26-42 W
52-84 W 120-277 50/60 CMBF84BU

Electrical Specification
Lamp Wattage Line Voltage Frequency (Hz) Line Amps Input Watts Min. Starting Temp
26 (1 x 26) 120-277 50/60 0.25-0.11 28 0 °F/-18 °C
32 (1 x 32) 120-277 50/60 0.27-0.12 36 0 °F/-18 °C
42 (1 x 42) 120-277 50/60 0.35-0.16 48 0 °F/-18 °C
52 (2 x 26) 120-277 50/60 0.49-0.20 55 -22 °F/-30 °C
64 (2 x 32) 120-277 50/60 0.57-0.24 67 -22 °F/-30 °C
84 (2 x 42) 120-277 50/60 0.73-0.31 87 -22 °F/-30 °C

➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.


➋ Denotes items that are suitable for Class I, Group B in addition to Class I, Groups C and D; and Class II, Groups E, F and G.
V CSA Certification only.
 Shaded items are suitable for Class I, Group C in addition to Class I, Group D; Class II, Groups E, F and G; and Class III.

1244 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

Catalog
Description Number
White Polyester Reflectors Furnished with stainless steel screws
For Globe Fixtures Standard Dome 26, 32, 42 W KR2-ST
30°Angle 26, 32, 42 W KR2-AN

Standard Dome 52, 64, 84 W CMR-4ST

30°Angle 52, 64, 84 W CMR-4AN

Standard Dome 30° Angle Dome Deep Dome 52, 64, 84 W CMR-4DD
Aluminum Reflectors

Lighting: Explosionproof — Area — Fluorescent


High Bay 52, 64, 84 W CMR-4HB

Prismatic Glass Globe and Ring Assembly


26, 32, 42 W CJGL-175

52, 64, 84 W CGL-400

CJGL-175 CGL-400
Aluminum Guards
26, 32, 42 W CJGU-15

52, 64, 84 W CGU-4

CJGU-15 CGU-4
Three-Way Exit Sign

Lighting
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.

26, 32, 42 W CJEXRN

52, 64, 84 W EXR400


Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.
Contact your sales representative regarding hazardous location suitability.

26, 32, 42 W AEXR-15R

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1245


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

Description Catalog Number


Replacement Parts – 26 W, 32 W, 42 W, 52 W, 64 W and 84 W

Socket (lampholder) G24Q-4 26 thru 84 W PLT32RS

PLT32RS CJSA42 Single Socket Bracket Assembly 26, 32, 42 W CJSA42

Double Socket Bracket Assembly 52, 64, 84 W CSA84


Lighting: Explosionproof — Area — Fluorescent

CSA84

Lamps

1 lamp = 26 W; 2 lamps = 52 W 26 W PLT26

1 lamp = 32 W; 2 lamps = 64 W 32 W PLT32

1 lamp = 42 W; 2 lamps = 84 W 42 W PLT42

Replacement Ballast

26, 32, 42 W 59661256001

52, 64, 84 W 59661259001

Connection Block

For all Code•Master fixtures VPT-7


Lighting

Fixture and Accessory Weights lbs/kgs Mounting Hood Weights lbs/kgs


Fixture Size Fixture Weight Reflector Weight Guard Weight Pendant Ceiling Bracket Stanchion
26 W, 32 W, 42 W 14.5/6.6 3.0/1.4 1.0/0.5 2/0.9 4/1.8 6/2.7 2/0.9
52 W, 64 W, 84 W 35.0/15.9 3.0/1.4 2.5/1.1

Reflector Dimensions
Catalog Dimensions in In/mm
Number Description A B C D Standard and Deep Dome 30° Angle
Standard Dome A A
KR2-ST 26, 32, 42 W 8.00/203.2 6.00/152.4 16.90/429.3 —
CMR-4ST 52, 64, 84 W 11.20/284.5 5.90/149.9 18.70/475.0 — B
B
Deep Dome
CMR-4DD 52, 64, 84 W 10.56/268.2 7.00/177.8 20.30/515.6 — D

30° Angle C
C
KR2-AN 26, 32, 42 W 8.00/203.2 2.75/69.9 14.90/378.5 10.17/258.3
CMR-4AN 52, 64, 84 W 10.56/268.2 5.00/127 16.16/410.5 9.75/247.7

1246 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

Mounting Hoods

Pendant Ceiling Bracket 25° Stanchion

9.50"/
2.46"/ 2.28"/ 241.3 mm
62.9 mm 57.9 mm
3.91"/99.3 mm 6.10"/
155.0 mm

4.00"/ 4.25"/ 4.50"/


9.86"/ 101.6 mm 4.92"/125.0 mm Sq. 108.0 mm
250.4 mm 114.3 mm
21.50"/ Dia.
546.1 mm 4.50"/
114.3 mm 1.23"/ 2.38"/
4.00"/
3.92"/ 31.2 mm 1.79"/ 60.5 mm
17.61"/ 101.6 mm 99.6 mm Dia.
20.50"/ 447.3 mm 3.48"/ 45.7 mm
520.7 mm 88.4 mm
5.92"/ 11.5"/
150.4 mm 292.1 mm
13.75"/
12.00"/ 349.3 mm
304.8 mm

26, 32, 42 W Fixture

Lighting: Explosionproof — Area — Fluorescent


0.94"/
23.9 mm
4.58"/
116.3 mm
Dia.

428.8 mm
4.00"/

16.88"/
101.6 mm
17.22"/ 3.75"/95.3 mm

406.4 mm
437.9 mm

16.00"/
17.47"/
443.7 mm
188.0 mm

396.7 mm
7.40"/

7.40"/

15.62"/
188.0 mm 7.40"/
18.12"/ 188.0 mm
453.9 mm
17.87"/

460.2 mm

412.8 mm
16.25"/
14.12"/
14.12"/ 358.6 mm
358.6 mm 16.25"/
412.8 mm

8.00"/ 8.00"/ 16.00"/


203.2 mm 203.2 mm 406.4 mm

52, 64, 84 W Fixture


593.3 mm
23.36"/

3.91"/
99.3 mm
250.4 mm
596.9 mm

9.86"/
23.5"/

538.5 mm
599.7 mm
250.4 mm
250.4 mm

23.61"/

21.2"/
618.7 mm

9.86"/

625.1 mm
9.86"/
622.3 mm

24.36"/

563.9 mm
24.61"/

22.2"/
24.5"/

517.1 mm

Lighting
20.36"/

20.36"/
517.1 mm
20.36"/
517.1 mm

17.5"/
12.0"/ 444.5 mm
304.8 mm
17.5"/
12.0"/ 5.5"/
139.7 mm
444.5 mm
304.8 mm

Exit Signs

6.88"/
9.25"/ 174.8 mm
235.0 mm

11.75"/298.5 mm

8.50"/
215.9 mm
12.00"/
304.8 mm

CJEXRN AEXR-15R

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1247


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

* Photometric data is based on a fixture with


a 32 W compact fluorescent PL-T lamp (2,400
lumens). For candlepower values of fixtures
with 26 W PL-T lamps (1,800 lumens), multiply by
0.75. For candlepower values of fixtures with a
42 W PL-T Lamp (3,200 lumens), multiply by 1.34.

Total Luminaire Efficiency = 92.9%


CIE Type - Semi-Direct REPORT NUMBER: CJBF32G
Spacing 32 W Fluorescent Lamp with Globe only *
Plane Criteria
0-180 2.76 Coefficients of Utilization - Zonal Cavity Method
90-270 2.76 Effective Floor Cavity Reflectance 0.20
Diagonal 2.72 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 103 103 103 103 97 97 97 97 85 85 85 74 74 74 65 65 65 60
0-10 9.75 1 88 81 75 70 82 76 70 65 65 61 57 56 53 50 48 45 42 38
10-20 32.89 2 78 67 59 52 72 63 55 49 54 48 43 46 41 37 38 35 31 27
20-30 68.63 3 69 57 48 41 64 53 45 38 46 39 33 39 33 29 32 28 24 20
Lighting: Explosionproof — Area — Fluorescent

30-40 119.65 4 63 50 40 33 58 46 37 31 39 32 27 33 28 23 28 23 19 16
40-50 174.44 5 57 43 34 27 52 40 32 25 35 27 22 29 23 19 24 19 16 13
50-60 219.68 6 52 38 29 23 48 36 27 21 31 24 18 26 20 16 21 17 13 10
60-70 252.32 7 48 34 25 19 44 32 24 18 27 21 16 23 18 13 19 15 11 9
70-80 278.38 8 44 31 22 17 41 29 21 16 25 18 14 21 16 11 18 13 9 7
80-90 283.11 9 41 28 20 14 38 26 19 14 23 16 12 19 14 10 16 12 8 6
90-100 266.38 10 38 25 18 13 35 24 17 12 21 15 10 18 12 9 15 10 7 5
100-110 231.16
110-120 166.66 Zonal Lumen Summary
120-130 91.63 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 31.38 Maximum Candela = 265 0-30 111.27 4.6 5.0 90-120 664.20 27.7 29.8
140-150 2.95 Located at Horizontal Angle = 0, Vertical Angle = 77.5 0-40 230.92 9.6 10.4 90-130 755.83 31.5 33.9
150-160 0.19 #1 - Vertical Plane through Horizontal Angles (0-180) 0-60 625.05 26.0 28.0 90-150 790.17 32.9 33.9
(Through Max. Cd.)
160-170 0.00 #2 - Horizontal Cone through Vertical Angle (77.5) 0-90 1438.87 60.0 64.5 90-180 790.36 32.9 35.5
170-180 0.00 (Through Max. Cd.) 0-180 2229.23 92.9 100.0

Total Luminaire Efficiency = 80.7%


CIE Type - Direct REPORT NUMBER: CJBF32ST
Spacing 32 W Fluorescent Lamp with Globe and Standard Dome Reflector *
Plane Criteria
0-180 1.42 Coefficients of Utilization - Zonal Cavity Method
90-270 1.42 Effective Floor Cavity Reflectance 0.20
Lighting

Diagonal 1.60 % Ceiling Rcc 80 70 50 30 10 0


% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 96 96 96 96 93 93 93 93 89 89 89 85 85 85 82 82 82 80
0-10 51.88 1 87 84 80 77 85 82 78 76 78 75 73 75 73 71 72 70 68 67
10-20 151.03 2 79 72 67 62 77 71 66 61 68 63 60 65 61 58 62 59 57 55
20-30 240.04 3 72 63 56 51 70 62 55 50 59 54 49 57 52 48 54 51 47 45
30-40 312.02 4 65 55 48 42 63 54 47 42 52 46 41 50 45 41 48 44 40 38
40-50 361.09 5 60 49 41 36 58 48 41 36 46 40 35 44 39 35 43 38 34 32
50-60 377.88 6 55 44 36 31 53 43 36 31 41 35 30 40 34 30 39 34 30 28
60-70 278.20 7 51 39 32 27 49 39 32 27 37 31 27 36 30 26 35 30 26 24
70-80 119.22 8 47 36 29 24 46 35 28 24 34 28 23 33 27 23 32 27 23 21
80-90 23.81 9 44 33 26 21 43 32 26 21 31 25 21 30 25 21 29 24 21 19
90-100 0.68 10 41 30 23 19 40 30 23 19 29 23 19 28 23 19 27 22 19 17
100-110 4.48
110-120 6.82 Zonal Lumen Summary
120-130 5.50 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 3.07 Maximum Candela = 545 0-30 442.95 18.5 22.9 90-120 11.98 0.5 0.6
140-150 0.09 Located at Horizontal Angle = 0, Vertical Angle = 5 0-40 754.97 31.5 39.0 90-130 17.48 0.7 0.9
150-160 0.00 #1 - Vertical Plane through Horizontal Angles (0-180) 0-60 1493.95 62.2 77.2 90-150 20.63 0.9 0.9
(Through Max. Cd.)
160-170 0.00 #2 - Horizontal Cone through Vertical Angle (5) 0-90 1915.18 79.8 98.9 90-180 20.63 0.9 1.1
170-180 0.00 (Through Max. Cd.) 0-180 1935.81 80.7 100.0

1248 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

* Photometric data is based on a fixture with ** Photometric data is based on a fixture PL-T Lamps. (3,200 lumens each) multiply by
a 32 W compact fluorescent PL-T lamp (2,400 with two 32 W Compact Fluorescent PL-T 1.34.
lumens). For candlepower values of fixtures lamps (2,400 lumens each). For candlepower
with 26 W PL-T lamps (1,800 lumens), multiply by values of fixtures with two 26 W PL-T lamps
0.75. For candlepower values of fixtures with a (1,800 lumens each), multiply by 0.75. For
42 W PL-T Lamp (3,200 lumens), multiply by 1.34. Candlepower values of fixtures with two 42 W

Total Luminaire Efficiency = 76.6%


CIE Type - Direct REPORT NUMBER: CJBF32AN
Spacing 32 W Fluorescent Lamp with Globe and 30° Angle Dome Reflector *
Plane Criteria
0-180 1.48 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 90 90 90 90 88 88 88 88 83 83 83 79 79 79 75 75 75 73
0-10 42.08 1 81 76 72 69 78 74 71 67 70 67 64 67 64 62 63 61 59 58
10-20 124.46 2 73 65 59 54 70 64 58 53 60 56 52 57 53 50 54 51 48 46
20-30 205.20 3 66 57 50 44 63 55 49 44 52 47 42 50 45 41 47 43 40 38
30-40 273.31 60 50 42 37 58 48 42 36 46 40 35 44 39 35 42 37 34 32

Lighting: Explosionproof — Area — Fluorescent


4
40-50 299.53 5 55 44 37 31 53 43 36 31 41 35 30 39 34 30 37 33 29 27
50-60 283.93 6 50 39 32 27 49 39 32 27 37 31 26 35 30 26 34 29 25 23
60-70 240.60 7 47 36 28 23 45 35 28 23 33 27 23 32 26 22 31 26 22 20
70-80 181.91 8 43 32 25 21 42 32 25 21 30 24 20 29 24 20 28 23 20 18
80-90 110.47 9 40 30 23 18 39 29 23 18 28 22 18 27 22 18 26 21 18 16
90-100 50.28 10 38 27 21 17 36 27 21 17 26 20 16 25 20 16 24 19 16 14
100-110 18.05
110-120 5.01 Zonal Lumen Summary
120-130 1.80 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 1.13 0-30 371.75 15.5 20.2 90-120 73.34 3.1 4.0
Maximum Candela = 467
140-150 0.05 Located at Horizontal Angle = 90, Vertical Angle = 40 0-40 645.06 26.9 35.1 90-130 75.13 3.1 4.1
150-160 0.00 #1 - Vertical Plane through Horizontal Angles (90-270) 0-60 1228.52 51.2 66.8 90-150 76.32 3.2 4.1
(Through Max. Cd.)
160-170 0.00 #2 - Horizontal Cone through Vertical Angle (40) 0-90 1761.50 73.4 95.8 90-180 76.32 3.2 4.2
170-180 0.00 (Through Max. Cd.) 0-180 1837.81 76.6 100.0

Total Luminaire Efficiency = 79.8%


CIE Type - Semi-Direct REPORT NUMBER: CMBF64G
Spacing 64 W (two 32 W lamps) Fluorescent Fixture with Globe only **
Plane Criteria
0-180 2.88 Coefficients of Utilization - Zonal Cavity Method
90-270 2.88 Effective Floor Cavity Reflectance 0.20

Lighting
Diagonal 2.82 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 90 90 90 90 85 85 85 85 76 76 76 68 68 68 60 60 60 57
0-10 17.70 1 76 70 65 60 71 66 61 57 58 54 51 51 48 45 45 42 40 36
10-20 61.05 2 67 58 51 45 63 55 48 42 48 43 38 42 37 34 36 32 29 26
20-30 132.44 3 60 49 41 35 56 46 39 33 40 34 29 35 30 26 30 26 23 20
30-40 236.78 4 54 43 34 28 50 40 32 26 35 28 23 30 25 21 26 21 18 15
40-50 336.66 5 49 37 29 23 46 35 27 22 31 24 19 26 21 17 23 18 15 12
50-60 421.68 6 45 33 25 19 42 31 23 18 27 21 16 23 18 14 20 16 12 10
60-70 485.34 7 41 29 22 16 38 28 20 15 24 18 14 21 16 12 18 14 10 8
70-80 517.29 8 38 26 19 14 36 25 18 13 22 16 12 19 14 10 16 12 9 7
80-90 513.72 9 35 24 17 12 33 23 16 11 20 14 10 17 12 9 15 11 8 9
90-100 468.70 10 33 22 15 11 31 21 14 10 18 13 9 16 11 8 14 10 7 5
100-110 352.77
110-120 200.85 Zonal Lumen Summary
120-130 73.54 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 11.28 0-30 211.19 4.4 5.5 90-120 1022.32 21.3 26.7
Maximum Candela = 493
140-150 1.12 Located at Horizontal Angle = 0, Vertical Angle = 70 0-40 447.97 9.3 11.7 90-130 1095.85 22.8 28.6
150-160 0.31 #1 – Vertical Plane through Horizontal Angles (0-180) 0-60 1206.31 25.1 31.5 90-150 1108.26 23.1 28.6
(Through Max. Cd.)
160-170 0.06 #2 – Horizontal Cone through Vertical Angle (70) 0-90 2722.64 56.7 71.1 90-180 1108.63 23.1 28.9
170-180 0.00 (Through Max. Cd.) 0-180 3831.28 79.8 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1249


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

** Photometric data is based on a fixture PL-T lamps. (3,200 lumens each) multiply by
with two 32 W Compact Fluorescent PL-T 1.34.
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

Total Luminaire Efficiency = 66.5%


REPORT NUMBER: CMBF64ST
CIE Type - Direct
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Spacing
Plane Criteria Standard Dome Reflector **
0-180 1.62 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.74 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 79 79 79 79 77 77 77 77 74 74 74 71 71 71 68 68 68 66
0-10 73.25 1 72 69 66 63 70 67 64 62 64 62 60 62 60 58 59 58 56 55
10-20 220.57 2 65 59 54 50 63 58 53 49 55 52 48 53 50 47 51 48 46 45
20-30 368.60 3 59 51 45 41 57 50 45 40 48 43 40 46 42 39 44 41 38 37
30-40 505.61 53 45 38 34 52 44 38 33 42 37 33 40 36 32 39 35 32 30
Lighting: Explosionproof — Area — Fluorescent

4
40-50 603.19 5 49 39 33 28 47 39 33 28 37 32 28 36 31 28 35 31 27 26
50-60 638.42 6 45 35 29 24 43 34 29 24 33 28 24 32 27 24 31 27 23 22
60-70 497.24 7 41 32 25 21 40 31 25 21 30 25 21 29 24 21 28 24 20 19
70-80 226.17 8 38 29 23 19 37 28 22 18 27 22 18 26 22 18 26 21 18 17
80-90 57.98 9 35 26 20 16 34 26 20 16 25 20 16 24 19 16 23 19 16 15
90-100 1.64 10 33 24 18 15 32 24 18 15 23 18 15 22 18 15 22 17 14 13
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 662.42 13.8 20.7 90-120 1.64 0.0 0.1
Maximum Candela = 808
140-150 0.00 Located at Horizontal Angle = 0, Vertical Angle = 35 0-40 1168.03 24.3 36.6 90-130 1.64 0.0 0.1
150-160 0.00 #1 – Vertical Plane through Horizontal Angles (0-180) 0-60 2409.64 50.2 75.5 90-150 1.64 0.0 0.1
(Through Max. Cd.)
160-170 0.00 #2 – Horizontal Cone through Vertical Angle (35) 0-90 3191.04 66.5 99.9 90-180 1.64 0.0 0.1
170-180 0.00 (Through Max. Cd.) 0-180 3192.68 66.5 100.0

Total Luminaire Efficiency = 57.4%


REPORT NUMBER: CMBF64AN
CIE Type - Direct
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Spacing
Plane Criteria
30° Angle Dome Reflector **
0-180 1.52 Coefficients of Utilization - Zonal Cavity Method
90-270 1.70 Effective Floor Cavity Reflectance 0.20
Lighting

Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0


% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 68 68 68 68 67 67 67 67 64 64 64 61 61 61 58 58 58 57
0-10 62.13 1 61 58 55 52 59 56 54 51 54 51 49 51 49 48 49 48 46 45
10-20 187.93 2 55 49 45 41 53 48 44 40 46 43 39 44 41 39 42 40 38 36
20-30 317.49 3 50 43 37 33 48 42 37 33 40 36 32 38 35 32 37 34 31 30
30-40 428.14 4 45 37 32 28 44 37 31 27 35 31 27 34 30 27 32 29 26 25
40-50 471.22 5 41 33 28 23 40 32 27 23 31 27 23 30 26 23 29 25 22 21
50-60 454.23 6 38 30 24 20 37 29 24 20 28 23 20 27 23 20 26 22 19 18
60-70 384.77 7 35 27 21 18 34 26 21 18 25 21 17 24 20 17 24 20 17 16
70-80 276.31 8 32 24 19 16 32 24 19 15 23 19 15 22 18 15 22 18 15 14
80-90 157.68 9 30 22 17 14 29 22 17 14 21 17 14 20 16 14 20 16 13 12
90-100 13.45 10 28 20 16 12 28 20 15 12 19 15 12 19 15 12 18 15 12 11
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 567.55 11.8 20.6 90-120 13.45 0.3 0.5
Maximum Candela = 731
140-150 0.00 Located at Horizontal Angle = 90, Vertical Angle = 37.5 0-40 995.69 20.7 36.2 90-130 13.45 0.3 0.5
150-160 0.00 #1 – Vertical Plane through Horizontal Angles (90-270) 0-60 1921.14 40.0 69.8 90-150 13.45 0.3 0.5
(Through Max. Cd.)
160-170 0.00 #2 – Horizontal Cone through Vertical Angle (37.5) 0-90 2739.90 57.1 99.5 90-180 13.45 0.3 0.5
170-180 0.00 (Through Max. Cd.) 0-180 2753.35 57.4 100.0

1250 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

** Photometric data is based on a fixture PL-T Lamps. (3,200 lumens each) multiply by
with two 32 W Compact Fluorescent PL-T 1.34.
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

Total Luminaire Efficiency = 67.2%


REPORT NUMBER: CMBF64DD
CIE Type - Direct
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Spacing
Plane Criteria Deep Dome Reflector **
0-180 1.44 Coefficients of Utilization - Zonal Cavity Method
90-270 1.44 Effective Floor Cavity Reflectance 0.20
Diagonal 1.60 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 80 80 80 80 78 78 78 78 75 75 75 71 71 71 69 69 69 67
0-10 88.95 1 73 70 67 65 71 68 66 63 66 63 61 63 61 60 60 59 58 56
10-20 260.61 2 66 61 56 52 65 59 55 52 57 53 50 55 52 49 53 50 48 47
20-30 413.34 3 60 53 47 43 59 52 47 43 50 45 42 48 44 41 46 43 40 39

Lighting: Explosionproof — Area — Fluorescent


30-40 539.82 4 55 47 41 36 53 46 40 36 44 39 35 42 38 35 41 37 34 33
40-50 630.36 5 50 41 35 31 49 41 35 30 39 34 30 38 33 30 37 33 29 28
50-60 641.74 6 46 37 31 26 45 36 30 26 35 30 26 34 29 26 33 29 25 24
60-70 436.60 7 43 33 27 23 41 33 27 23 32 27 23 31 26 23 30 26 22 21
70-80 164.84 8 40 30 24 20 38 30 24 20 29 24 20 28 23 20 27 23 20 19
80-90 47.37 9 37 28 22 18 36 27 22 18 26 21 18 26 21 18 25 21 18 16
90-100 1.92 10 34 25 20 16 34 25 20 16 24 19 16 24 19 16 23 19 16 15
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 762.91 15.9 23.7 90-120 1.92 0.0 0.1
Maximum Candela = 933
140-150 0.00 Located at Horizontal Angle = 0, Vertical Angle = 7.5 0-40 1302.73 27.1 40.4 90-130 1.92 0.0 0.1
150-160 0.00 #1 – Vertical Plane through Horizontal Angles (0-180) 0-60 2574.82 53.6 79.8 90-150 1.92 0.0 0.1
(Through Max. Cd.)
160-170 0.00 #2 – Horizontal Cone through Vertical Angle (7.5) 0-90 3223.63 67.2 99.9 90-180 1.92 0.0 0.1
170-180 0.00 (Through Max. Cd.) 0-180 3225.55 57.4 100.0

Total Luminaire Efficiency = 58.9%


CIE Type - Direct REPORT NUMBER: CMBF64HB
Spacing 64 W (two 32 W lamps) Fluorescent Fixture with Globe and High Bay Reflector **
Plane Criteria
0-180 0.82 Coefficients of Utilization - Zonal Cavity Method
90-270 0.82 Effective Floor Cavity Reflectance 0.20

Lighting
Diagonal 0.92 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 70 70 70 70 68 68 68 68 65 65 65 63 63 63 60 60 60 59
0-10 239.15 1 66 64 63 61 65 63 62 60 61 59 58 58 57 57 56 56 55 54
10-20 599.67 2 62 59 56 54 61 58 55 53 56 54 52 54 52 51 52 51 50 49
20-30 645.20 3 58 54 51 48 57 53 50 47 51 49 47 50 48 46 49 47 45 44
30-40 625.54 4 55 50 46 43 54 49 45 43 48 44 42 46 44 42 45 43 41 40
40-50 452.95 5 51 46 42 39 50 45 41 39 44 41 38 43 40 38 42 39 37 36
50-60 185.71 6 48 42 38 35 47 42 38 35 41 37 35 40 37 35 39 36 34 33
60-70 58.40 7 46 39 35 32 45 39 35 32 38 35 32 37 34 32 37 34 32 31
70-80 15.26 8 43 37 33 30 42 36 32 30 36 32 30 35 32 29 34 31 29 28
80-90 4.25 9 41 34 30 28 40 34 30 28 33 30 27 33 30 27 32 29 27 26
90-100 0.69 10 38 32 28 26 38 32 28 26 31 28 26 31 28 25 30 27 25 25
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 1484.03 30.9 52.5 90-120 0.69 0.0 0.0
Maximum Candela = 2540
140-150 0.00 Located at Horzonatl Angle = 0, Vertical Angle = 5 0-40 2109.57 43.9 74.6 90-130 0.69 0.0 0.0
150-160 0.00 #1 – Vertical Plane through Horizontal Angles (0-180) 0-60 2748.23 57.3 97.2 90-150 0.69 0.0 0.0
(Through Max. Cd.)
160-170 0.00 #2 – Horizontal Cone through Vertical Angle (5) 0-90 2826.12 58.9 100.0 90-180 0.69 0.0 0.0
170-180 0.00 (Through Max. Cd.) 0-180 2628.80 58.9 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1251


© September 2010
APL Two and Four Lamp Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.

Class I, Division 1 and 2, Groups C,D


Class II, Division 1 and 2, Groups E,F,G
Class III
Marine Type Electric Fixture Inside Drip-Proof
Type

Applications
• Classified areas where ignitable gases and vapors, dusts,
paint residue, paint powder, or corrosive atmospheres may be
present, or where excessive moisture is a problem.
• Approved for mounting directly inside a paint spray booth.
Complies with NEC 516-3(b) and NFPA No. 33.
• Typical applications include refineries, chemical and
petrochemical plants, textile mills, grain elevators and other
grain-processing facilities, pharmaceutical plants, and paint Two Lamp APL
spray areas.
Features
• Factory sealed fixture. No external seals needed for
classified areas.
• Two lamp:
Lighting: Explosionproof — Area — Fluorescent

— Compact size
— Uses two single-ended biaxial 40 W fluorescent lamps in a
fixture only 29”/736.6 mm long
— Available for 120-277 V, 50/60 Hz
— Available for 120 V, 277 V, 347 V, 50/60 Hz V
• Four lamp:
— Uses four single-ended biaxial 40 W fluorescent lamps Two Lamp APL with Optional Reflector
mounted tandem in a 52-1/2”/1333.5 mm long fixture
— Available for 120-277 V, 50/60 Hz
— Available for 120 V, 277 V, 347 V, 50/60 Hz V
• Easy to install. Has three 3/4”/19.1 mm conduit hubs on each
end of fixture. Two close-up plugs per end are furnished.
Mounts straight down, or at 45° angle to either side. Can be
mounted horizontally, or mounted vertically on wall. Gasketed
end caps remove easily for wiring or relamping.
• Explosionproof, heat-resistant and impact-resistant glass
tubes protect lamps.
• Cool-operating fluorescent lamps provide excellent color Four Lamp APL
rendition and high lumen output per watt. Average lamp life
is 20,000 hours. Lamps are furnished.
• Corrosion resistant.
• Reflector (optional) is designed for efficient distribution.
Installs and removes using only a screwdriver.
• Appleton APL fixtures are supplied with energy-saving Class
P ballasts, equipped with an automatic thermally activated
Lighting

protective device.
Standard Materials
• End housing: copperfree (4/10 of 1% max.) aluminum
• Housing hood and optional reflectors: heavy gauge aluminum Four Lamp APL with Optional Reflector
• Wire guard: stainless steel
Standard Finishes
• End housings and hood: two-coat baked gray epoxy finish
• Reflector: white baked powder coat polyester reflecting surface
Illustrated Feature
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E10794
• CSA Standard: C22.2 No. 250, C22.2 No. 137
APL Fixture shown with explosionproof,
• CSA Certified: 025428
gasketed end caps removed, allowing
access for wiring and relamping.

V CSA Certification only.

1252 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
APL Two and Four Lamp Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.

Class I, Division 1 and 2, Groups C,D


Class II, Division 1 and 2, Groups E,F,G
Class III
Marine Type Electric Fixture Inside Drip-Proof
Type

Lamps Hub Size Temperature Supply Wire Catalog


(Included) Volts (Inches) Rating °F/°C Number
Luminaires Without Reflector
Two Lamp
(2) 40 W F40BX 120-277 3/4 T-6 140/60 APL240BU
(2) 40 W F40BX 3477 3/4 T-6 140/60 APL240-347 V

Four Lamp
(4) 40 W F40BX 120-277 3/4 T6 140/60 APL440BU

Lighting: Explosionproof — Area — Fluorescent


(4) 40W F40BX 347 3/4 T-6 60°C APL440-347 V

Aluminum reflector with white powder coat polyester finish


Two Lamp APL2R
Four Lamp APL4R

Wire Guard
Two Lamp APL-2-GU-SS
Four Lamp ARS-GU-SS

Exit Sign — 6” red lettering on white enamel field


Two Lamp Only APLEXR

Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1253


© September 2010
APL Two Lamp Factory Sealed Luminaire Dimensions and Photometric Data
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.

Dimensions

5.5"/ 22.75"/
(3) 3/4" Conduit Holes on 139.7 mm 577.9 mm
Each End, Furnished with
Two Close-Up Plugs 29.00"/
736.6 mm

8.75"/ 7.75"/
222.3 mm 196.9 mm

8.75"/
222.3 mm Side View — Without Optional Reflector
16.00"/
406.4 mm
End View —With Optional Reflector

APL240
Lighting: Explosionproof — Area — Fluorescent

Photometric Data

Total Luminaire Efficiency = 81.4%

CIE Type - Direct REPORT NUMBER: APL240R


Spacing Lamps: Two 40 W Two-Foot Explosionproof Fluorescent
Plane Criteria

0-180 1.28 Coefficients of Utilization - Zonal Cavity Method

90-270 1.50 Effective Floor Cavity Reflectance 0.20

Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Zone Lumens 0 97 97 97 97 95 95 95 95 90 90 90 87 87 87 83 83 83 81
0-10 143.58 1 88 84 81 77 86 82 79 76 79 76 74 76 73 71 73 71 69 68
10-20 422.85 2 80 73 67 62 78 71 66 62 68 64 60 66 62 59 63 60 57 56
20-30 667.66 3 72 64 57 51 70 62 56 51 60 54 50 58 53 49 55 51 48 46
30-40 852.03 4 66 56 49 43 64 55 48 43 53 47 42 51 46 41 49 45 41 39
Lighting

40-50 948.58 5 61 50 42 37 59 49 42 36 47 41 36 45 40 35 44 39 35 33
50-60 920.43 6 56 44 37 32 54 44 37 31 42 36 31 41 35 31 40 34 31 29
60-70 709.76 7 52 40 33 28 50 39 33 28 38 32 27 37 31 27 36 31 27 25
70-80 373.12 8 48 37 29 24 47 36 29 24 35 29 24 34 28 24 33 28 24 22
80-90 87.31 9 45 33 27 22 43 33 26 22 32 26 22 31 26 22 30 25 21 20
90-100 0.00 10 42 31 24 20 41 30 24 20 29 24 20 29 23 19 28 23 19 18
100-110 0.00

110-120 0.00 Zonal Lumen Summary

120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 1234.09 19.6 24.1 90-120 0.00 0.0 0.0
140-150 0.00 0-40 2086.12 33.1 40.7 90-130 0.00 0.0 0.0
150-160 0.00 0-60 3955.13 62.8 77.2 90-150 0.00 0.0 0.0
160-170 0.00 0-90 5125.31 81.4 100.0 90-180 0.00 0.0 0.0
170-180 0.00 0-180 5125.32 81.4 100.0

V CSA Certification only.

1254 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
APL Four Lamp Fluorescent Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.

Total Luminaire Efficiency = 79.9%

CIE Type - Direct REPORT NUMBER: APL440R


Spacing Lamps: Four 40 W Explosionproof Fluorescent
Plane Criteria

0-180 1.30 Coefficients of Utilization - Zonal Cavity Method

90-270 1.50 Effective Floor Cavity Reflectance 0.20

Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Zone Lumens 0 95 95 95 95 93 93 93 93 89 89 89 85 85 85 82 82 82 80
0-10 277.70 1 87 83 79 76 85 81 78 75 78 75 73 74 72 70 72 70 68 67

Lighting: Explosionproof — Area — Fluorescent


10-20 817.61 2 78 72 66 61 76 70 65 61 67 63 59 65 61 58 62 59 56 55
20-30 1291.05 3 71 62 56 50 69 61 55 50 59 53 49 57 52 48 54 51 47 45
30-40 1648.83 4 65 55 48 42 63 54 47 42 52 46 41 50 45 41 48 44 40 38
40-50 1837.13 5 59 49 41 36 58 48 41 36 46 40 35 45 39 35 43 38 35 33
50-60 1787.64 6 55 44 36 31 53 43 36 31 41 35 31 40 35 30 39 34 30 28
60-70 1379.79 7 51 39 32 27 49 39 32 27 38 31 27 36 31 27 35 30 26 25
70-80 722.47 8 47 36 29 24 46 35 29 24 34 28 24 33 28 24 32 27 24 22
80-90 148.89 9 44 33 26 22 43 32 26 21 31 25 21 31 25 21 30 25 21 20
90-100 0.00 10 41 30 24 19 40 30 24 19 29 23 19 28 23 19 28 23 19 18
100-110 0.00

110-120 0.00 Zonal Lumen Summary

120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 2386.36 19.2 24.1 90-120 0.00 0.0 0.0
140-150 0.00 0-40 4035.19 32.5 40.7 90-130 0.00 0.0 0.0
150-160 0.00 0-60 7659.96 61.8 77.3 90-150 0.00 0.0 0.0
160-170 0.00 0-90 9911.11 79.9 100.0 90-180 0.00 0.0 0.0
170-180 0.00 0-180 9911.11 79.9 100.0

Lighting
(3) 3/4" Conduit Holes on
Each End, Furnished with
Two Close-Up Plugs 46.63"/
5.5"/139.7 mm 1184.4 mm
52.5"/
1333.5 mm
7.75"/
8.75"/ 196.9 mm
222.3 mm
8.75"/
222.3 mm Side View — Without Optional Reflector
16.00"/
406.4 mm
End View —With Optional Reflector

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1255


© September 2010
EFU Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• Classified areas such as inside paint spray booths, in
pharmaceutical firms, paint-manufacturing plants, printing
plants or any location where ignitable dust, fumes, gases,
paint residue, paint powder or corrosive atmospheres may be
present.
Features
• Factory sealed unit – no external seals required.
Installation is easy.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Three hubs on each end of fixture provide for straight-down
mounting or at 45° to either side. Two close-up plugs furnished
for each end of fixture.
Lighting: Explosionproof — Area — Fluorescent

• Explosionproof, impact-resistant and heat-resistant glass tubes


protect lamps.
• Reflectors can easily be removed for replacement or cleaning
using only a screwdriver.
• Appleton EFU fixtures are supplied with Class P ballasts,
equipped with an automatic thermally activated protective
device. They offer protection against excessive voltage, internal
ballast short circuiting, inadequate lamp maintenance and
improper fixture application.
• Non-sparking exterior surfaces for safer operation.
Standard Materials
• Hood, housings and reflectors: copperfree (4/10 of 1% max.)
aluminum
• Hood and housings: gray epoxy finish
• Reflectors: white baked enamel inside and gray epoxy outside
Options
• Emergency battery pack. Suffix -EL.
• Fusing: ARS, AH and AVH fixtures supplied as standard with
Class P ballasts with built-in protective device. Additional
external fusing available at extra cost. Suffix -F.
Certifications and Compliances
• UL Standard: UL 1598, UL 844
Lighting

• UL Listed: E10794
• CSA Standard: C22.2 No. 250, C22.2 No. 137
• CSA Certified: 025428

Explosionproof caps easily removed


(shown with caps removed) for easy access.
Allows quick wiring or relamping.

1256 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
EFU Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Hub Size Temperature Supply Wire Catalog


Lamp Volts
(Inches) Rating °F/°C Number ➋
Two Lamps
32 W
Rapid Start 120-277 V, 50/60 Hz 3/4 T-6 140/60 ARS232-BU ➊
T8 Bi-Pin
48” 265MA 347 V, 60 Hz 3/4 T-6 140/60 ARS232-347 V➊
40 W
Rapid Start 120-277 V, 50/60 Hz 3/4 T-6 140/60 ARS240-BU ➊
T12 Bi-Pin
48” 430MA 347 V, 60 Hz 3/4 T-6 140/60 ARS240-347 V➊
60 W
Rapid Start High Output 120-277 V, 50/60 Hz 3/4 T-6 140/60 AH260-BU
T-12 Recessed Double Contact
48” 800MA 347 V, 60 Hz 3/4 T-6 140/60 AH260-347 V

Lighting: Explosionproof — Area — Fluorescent


110 W
Rapid Start VHO-SHO 120 V, 60 Hz 3/4 T-6 140/60 AVH210-118
T-12 Recessed Double Contact 277 V, 60 Hz 3/4 T-6 140/60 AVH210-277
48” 1500MA 347 V, 60 Hz 3/4 T-6 140/60 AVH210-347 V
Three Lamps
32 W
Rapid Start 120-277 V, 50/60 Hz 3/4 T-6 140/60 ARS332-BU ➊
T8 Bi-Pin
48” 265MA 347 V, 60 Hz 3/4 T-6 140/60 ARS332-347 V➊
40 W
Rapid Start 120-277 V, 50/60 Hz 3/4 T-6 140/60 ARS340-BU
T12 Bi-Pin
48” 430MA 347 V, 60 Hz 3/4 T-6 140/60 ARS340-347 V
60 W
Rapid Start High Output 120-277 V, 50/60 Hz 3/4 T-6 140/60 AH360-BU
T-12 Recessed Double Contact
48” 800MA 347 V, 60 Hz 3/4 T-6 140/60 AH360-347 V
Four Lamps
32 W
Rapid Start 120-277 V, 50/60 Hz 3/4 T-6 140/60 ARS432-BU ➊
T8 Bi-Pin
48” 265MA 347 V, 60 Hz 3/4 T-6 140/60 ARS432-347 V➊
40 W

Lighting
Rapid Start 120-277 V, 50/60 Hz 3/4 T-6 140/60 ARS440-BU
T12 Bi-Pin
48” 430MA 347 V, 60 Hz 3/4 T-6 140/60 ARS440-347 V
60 W
Rapid Start High Output 120-277 V, 50/60 Hz 3/4 T-6 140/60 AH460-BU
T-12 Recessed Double Contact
48” 800MA 347 V, 60 Hz 3/4 T-6 140/60 AH460-347 V
110 W
Rapid Start Very High Output 120 V, 60 Hz 3/4 T-6 140/60 AVH410-118
T-12 Recessed Double Contact 277 V, 60 Hz 3/4 T-6 140/60 AVH410-277
48” 1500MA 347 V, 60 Hz 3/4 T-6 140/60 AVH410-347 V
Protector for two-lamp fluorescent fixture
Fits two lamp 48” fixtures only (ARS, AH and AVH series)
UV stabilized polycarbonate. EFP248

NOTE: In paint spray areas, solvents and thinners may “cloud” the polycarbonate. Light transmission characteristics may be reduced.
➊ For Emergency Battery Pack, add suffix -EL.
➋ Fluorescent lamps are not included. Supplied with automatic resetting dual protected “Class P” ballast. For additional external fusing, add suffix -F.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1257


© September 2010
EFU Fluorescent Factory Sealed Luminaire Ballast Data and Dimensions
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations

Catalog Operating Input Starting Temperature


Number Lamps Hz Voltage Amps Watts °F/°C
32 W Rapid Start T-8 Bi-Pin 48” 265 mA
ARS232-BU 2 50/60 120-277 .52-.22 62-60 0/-18
ARS232-347 V 2 60 347 .20 59 0/-18
ARS332-BU 3 50/60 120-277 .78-.33 93-93 0/-18
ARS332-347 V 3 60 347 .30 86 0/-18
ARS432-BU 4 50/60 120-277 1.03-.43 124-120 0/-18
ARS432-347 V 4 60 347 .40 118 0/-18
40 W Rapid Start T-12 Bi-Pin 48” 430 mA
Lighting: Explosionproof — Area — Fluorescent

ARS240-BU 2 50/60 120-277 .70-.35 84-42 50/10


ARS240-347 V 2 60 347 .30 96 50/10
ARS340-BU 3 50/60 120-277 .99-.45 114 50/10
ARS340-347 V 3 60 347 .50 140 50/10
ARS440-BU 4 50/60 120-277 1.40-.70 168-84 50/10
ARS440-347 V 4 60 347 .60 192 50/10
60 W Rapid Start High Output T-12 Bi-Pin 48” 800 mA
AH260-BU 2 50/60 120-277 1.05-.55 122-86 -20/-29
AH260-347 V 2 60 347 .50 145 -20/-29
AH360-BU 3 50/60 120-277 1.54-.66 182 -20/-29
AH360-347 V 3 60 347 .90 256 -20/-29
AH460-BU 4 50/60 120-277 2.10-1.10 244-172 -20/-29
AH460-347 V 4 60 347 1.00 290 -20/-29
110 W Rapid Start VHO-SHO T-12 Bi-Pin 48” 1500 mA
AVH210-118 2 60 120 2.60 300 -20/-29
AVH210-277 2 60 277 .98 250 -20/-29
Lighting

AVH210-347 V 2 60 347 .90 250 -20/-29


AVH410-118 4 60 120 5.20 600 -20/-29
AVH410-277 4 60 277 1.96 500 -20/-29
AVH410-347 V 4 60 347 1.80 500 -20/-29
Dimensions in In/mm
152.4 mm

152.4 mm
6.00"/

6.00"/

8.75"/
4.00"/101.6 mm 222.3 mm

No. of Lamps A B C D E
2 46-5/8/1184.4 52-7/16/1332.0 8-3/4/222.3 5-1/2/139.7 15/381.0
3 46-5/8/1184.4 52-7/16/1332.0 8-3/4/222.3 5-1/2/139.7 19-1/4/489.0
4 46-5/8/1184.4 52-7/16/1332.0 11-7/16/290.6 14/355.6 23-1/2/596.9

1258 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
EFU Fluorescent Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations

* Data is based on F32 TB Rapid Start


Lamps. For other lamps use the following
multipliers: 60 W Cool White – 1.50; and 110
W VHO – 2.19. Candlepower distribution
curves and other coefficients of utilization
tables are available on request.

Zone Lumens Total Luminaire Efficiency = 78.6%


0-10 139.50 CIE Type - Direct REPORT NUMBER: ARS232
10-20 402.70 Spacing Lamps: Two 32 W Explosionproof Fluorescent with Reflector *
20-30 620.06 Plane Criteria
30-40 767.75 0-180 1.28 Coefficients of Utilization - Zonal Cavity Method
40-50 821.07 90-270 1.36 Effective Floor Cavity Reflectance 0.20
50-60 776.93 Diagonal 1.44 % Ceiling Rcc 80 70 50 30 10 0
60-70 597.35 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 299.18 Zonal Lumen Summary 0 94 94 94 94 91 91 91 91 87 87 87 84 84 84 80 80 80 79
80-90 57.43 Zone Lumens % Lamp % Fixture 1 86 82 78 75 83 80 77 74 77 74 72 74 72 70 71 69 68 66
90-100 0.00 0-30 1162.26 20.4 25.9 2 78 71 66 61 76 70 65 60 67 63 59 64 61 58 62 59 56 55
100-110 0.00 0-40 1930.01 33.9 43.1 3 71 62 56 51 69 61 55 50 59 53 49 56 52 48 54 51 47 46
110-120 0.00 0-60 3528.01 61.9 78.7 4 65 55 48 43 63 54 47 42 52 46 42 50 45 41 48 44 41 39
120-130 0.00 0-90 4481.97 78.6 100.0 5 59 49 42 36 58 48 41 36 46 40 36 45 40 35 43 39 35 33

Lighting: Explosionproof — Area — Fluorescent


130-140 0.00 90-120 0.00 0.0 0.0 6 55 44 37 32 53 43 36 32 42 36 31 40 35 31 39 34 31 29
140-150 0.00 90-130 0.00 0.0 0.0 7 51 40 33 28 49 39 32 28 38 32 28 37 31 27 36 31 27 25
150-160 0.00 90-150 0.00 0.0 0.0 8 47 36 29 25 46 36 29 25 35 29 24 34 28 24 33 28 24 23
160-170 0.00 90-180 0.00 0.0 0.0 9 44 33 27 22 43 33 26 22 32 26 22 31 26 22 30 25 22 20
170-180 0.00 0-180 4481.97 78.6 100.0 10 41 31 24 20 40 30 24 20 29 24 20 29 23 20 28 23 20 18

Zone Lumens Total Luminaire Effieciency = 96.8%


0-10 249.94 CIE Type - Direct REPORT NUMBER: ARS332
10-20 726.14 Spacing Lamps: Three 32 W Explosionproof Fluorescent with Reflector *
20-30 1122.12 Plane Criteria
30-40 1392.92 0-180 1.26 Coefficients of Utilization - Zonal Cavity Method
40-50 1496.9 90-270 1.38 Effective Floor Cavity Reflectance 0.20
50-60 1397.8 Diagonal 1.46 % Ceiling Rcc 80 70 50 30 10 0
60-70 1087.36 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 557.01 Zonal Lumen Summary 0 115 115 115 115 113 113 113 113 108 108 108 103 103 103 99 99 99 97
80-90 103.54 Zone Lumens % Lamp % Fixture 1 105 101 97 93 103 99 95 91 94 91 88 91 88 86 87 85 83 81
90-100 0.00 0-30 2098.20 25.0 25.8 2 96 87 81 75 93 86 80 74 82 77 73 79 75 71 76 72 69 67
100-110 0.00 0-40 3491.12 41.6 42.9 3 87 77 69 62 84 75 68 62 72 66 60 69 64 59 67 62 58 56
110-120 0.00 0-60 6385.81 76.0 78.5 4 79 68 59 52 77 66 58 52 64 57 51 62 55 50 59 54 50 48
120-130 0.00 0-90 8133.73 96.8 100.0 5 73 60 51 45 71 59 51 45 57 50 44 55 49 44 53 48 43 41
130-140 0.00 90-120 0.00 0.0 0.0 6 67 54 45 39 65 53 45 39 51 44 38 50 43 38 48 42 38 36
140-150 0.00 90-130 0.00 0.0 0.0 7 62 49 40 34 60 49 40 34 47 39 34 45 38 34 44 38 33 31
150-160 0.00 90-150 0.00 0.0 0.0 8 58 44 36 30 56 44 36 30 42 35 30 41 35 30 40 34 30 28

Lighting
160-170 0.00 90-180 0.00 0.0 0.0 9 54 41 33 27 53 40 32 27 39 32 27 38 31 27 37 31 27 25
170-180 0.00 0-180 8133.73 96.8 100.0 10 50 38 30 25 49 37 30 25 36 29 24 35 29 24 34 28 24 22

Zone Lumens Total Luminaire Effieciency = 70.9%


0-10 237.58 CIE Type - Direct REPORT NUMBER: ARS432
10-20 692.75 Spacing Lamps: Four 32 W Explosionproof Fluorescent with Reflector *
20-30 1081.02 Plane Criteria
30-40 1352.75 0-180 1.28 Coefficients of Utilization - Zonal Cavity Method
40-50 1467.39 90-270 1.42 Effective Floor Cavity Reflectance 0.20
50-60 1408.53 Diagonal 1.48 % Ceiling Rcc 80 70 50 30 10 0
60-70 1130.45 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 598.78 Zonal Lumen Summary 0 84 84 84 84 82 82 82 82 79 79 79 75 75 75 72 72 72 71
80-90 117.42 Zone Lumens % Lamp % Fixture 1 77 74 70 68 75 72 69 67 69 67 64 66 64 62 64 62 61 59
90-100 0.00 0-30 2011.34 17.6 24.9 2 70 64 59 55 68 62 58 54 60 56 53 57 54 51 55 53 50 49
100-110 0.00 0-40 3364.10 29.5 41.6 3 63 56 50 45 62 54 49 44 52 48 44 50 46 43 48 45 42 41
110-120 0.00 0-60 6240.02 54.7 77.2 4 58 49 43 38 56 48 42 37 46 41 37 45 40 36 43 39 36 34
120-130 0.00 0-90 8086.66 70.9 100.0 5 53 44 37 32 51 43 37 32 41 36 32 40 35 31 38 34 31 29
130-140 0.00 90-120 0.00 0.0 0.0 6 49 39 33 28 47 38 32 28 37 32 27 36 31 27 35 30 27 25
140-150 0.00 90-130 0.00 0.0 0.0 7 45 35 29 24 44 35 29 24 34 28 24 33 28 24 32 27 24 22
150-160 0.00 90-150 0.00 0.0 0.0 8 42 32 26 22 41 32 26 22 31 25 21 30 25 21 29 24 21 20
160-170 0.00 90-180 0.00 0.0 0.0 9 39 29 23 19 38 29 23 19 28 23 19 27 23 19 27 22 19 18
170-180 0.00 0-180 8086.66 70.9 100.0 10 37 27 21 18 36 27 21 17 26 21 17 25 21 17 25 20 17 16

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1259


© September 2010
PAPL Portable Two and Four Lamp Fluorescent Factory Sealed Luminaire
Explosionproof, Dust-Ignitionproof
120 V. Suitable for Wet Locations and Paint Spray Booths. UL Listed for Horizontal use only.

Class I, Division 1 and 2, Groups C, D

Applications
• Classified areas where ignitable gases and vapors, dusts,
paint residue, paint powder, or corrosive atmospheres may be
present, or where excessive moisture is a problem.
• Approved for using directly inside a paint-spray booth.
Complies with NEC 516-3(c) and NFPA No. 33.
• Typical applications include aircraft manufacturing and
maintenance facilities, refineries, chemical and petrochemical
plants, textile mills, grain elevators and other grain-processing
facilities, pharmaceutical plants, paint-spray areas, and where
the permanent mounting of a fixture is not practical.
• UL approved for horizontal use only.
4-Lamp Luminaire
Features
• Factory sealed fixture. No external seals needed for
Lighting: Explosionproof — Area — Fluorescent

classified areas.
• Compact size. Uses two or four single-ended biaxial 40 W
fluorescent lamps in a portable fixture. (2 lamp cart overall
length is 38-1/2”/978 mm, 4 lamp cart overall length is 62”).
• Gasketed end caps remove easily for wiring and relamping.
• Teflon-coated stainless steel wire guard supplied standard.
• Adjustable aluminum mounting frame allows fixtures to pivot at
45° increments in a 180° horizontal plane.
• 50’ of 16-3 SOW cord with nonmetallic explosionproof plug
prewired for 120 V.
• Static discharge wheels.
• Explosionproof, heat-resistant and impact-resistant glass tubes
help protect the lamp.
• Cool-operating fluorescent lamps provide excellent color 2-Lamp Luminaire
rendition and high lumen output per watt. Average lamp life is
20,000 hours.
• Corrosion resistant.
• Reflectors (optional) are designed for efficient distribution.
Easily installed using only a screwdriver.
• Energy-saving Class P ballasts, with automatic thermally
activated protective device.
• Fixture uses Appleton’s ECP1523 Plug, which is UL Classified
for use with Killark® UGR and Crouse-Hinds® ENR series
receptacles, as well as Appleton’s U-Line receptacles.
Lighting

Standard Materials
• End housing, cord grip and elbow: copperfree (4/10 of 1%
max.) aluminum
• Housing hood, frame and optional reflectors: heavy gauge
aluminum
• Wheels: static discharge rubber
• Guard: Teflon coated stainless steel
• Plug: aluminum
Standard Finishes
• End housings and hood: two-coat baked gray epoxy finish
• Reflector: white baked powder coat polyester
• Frame assembly: natural aluminum
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E59147
• CSA Standard: C22.2 No. 12, C22.2 No. 137
• cUL Listed: E59147

1260 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
PAPL Portable Two and Four Lamp Fluorescent Factory Sealed Luminaire
Explosionproof, Dust-Ignitionproof
120 V. Suitable for Wet Locations and Paint Spray Booths. UL Listed for Horizontal use only.

Class I, Division 1 and 2, Groups C, D

Lamps Temperature Catalog


Included Volts Rating Number
Two-Lamp Luminaires Less Reflector
(2) 40 W F40BX 120 T6 PAPL240-120

Reflector Only
Aluminum reflector with white powder coat polyester finish
APL2R

Four-Lamp Luminaires Less Reflector

Lighting: Explosionproof — Area — Fluorescent


(4) 40 W F40BX 120 T6 PAPL440-120

Two-Lamp Luminaire Illustrated Reflector Only


Aluminum reflector with white powder coat polyester finish APL4R

Dimensions in Inches/Millimeters

13.88"/ 18.00"/
352.6 mm 457.2 mm

8.50"/
5.00"/ 215.9 mm
127.0 mm
Dia.

Lighting
14.00"/
355.6 mm

18.00"/ 62.00"/1574.8 mm 4 Lamp


457.2 mm 38.50"/977.9 mm 2 Lamp

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1261


© September 2010
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/68

Applications
• Can be installed in hazardous areas designated as Zone 1, 2, 21
and 22.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor/outdoor use where protection against dirt, water and
moisture is necessary. 2 x 58 W
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper, mills, painting, sewage and water
treatment facilities, warehouses, underground tunnels and
general manufacturing facilities.
Features 2 x 36 W
• Impact resistant borosilicate glass sealed tube.
• Easy access to lamps through gray painted Zamak
Lighting: Explosionproof — Area — Fluorescent

threaded entry cap.


• Supplied with O-ring for improved ingress protection.
• Corrosion-resistant gray painted Zamak.
• Supplied with energy efficient and self induction ferromagnetic 2 x 18 W
ballast on a removable gear tray.
• Quick and easy installation of fluorescent lighting fixtures with
2G11 and G13 lamp holders. Certifications and Compliances
• Supplied with external and internal ground/earth connection.
• Fixture supplied with one M20 blanking plug. • Certification Type: FLd
• Easy connection to wire and disconnect with plug-in • Zone 1 and 2
terminal blocks. — Conforming to ATEX 94/9/CE: CE 0081 II 2 G
• Bi-pin (G13) 18 & 36 W magnetic ballast versions operate at — ATEX/IEC Protection: Ex d IIB, Ex d IIB+H2, Ex d IIC
158°F/70°C ambient temperature with T4 rating. — T Rating: (See table)
• Magnetic ballast versions 230 V 50 Hz or 240 V 50 Hz or 220 V • Zone 21 and 22
60 Hz or 230 V 60 Hz. — Conforming to ATEX 94/9/CE: CE II 2 D
— ATEX/IEC Protection: Ex tD A21
• Electronic ballast versions 110 to 254 Vac/Vdc 50/60 Hz.
— Surface Temperature: (See table)
• 3 hour emergency version with automatic self test every month
• Ambient Temperature: -4°F to 131°F / -20°C to 55°C
• Plug in battery pack (6 V 4 Ah) is easy to remove for
• CE Declaration of Conformity: 50203
maintenance.
• ATEX Certificate: LCIE 97 ATEX 6012
Standard Materials • IECEx Certificate: IECEx LCI 04.0018
• End caps and cover: gray painted Zamak • Other Certifications: GOST
• Glass tube: borosilicate • Index of Protection (solid & liquid): IP66/68
• O-ring gasket: Nitrile (NBR) • Impact Resistance (shock): IK08
• Internal reflector: white powder coated galvanized steel • Internal Volume: > 122.05in3/2 dm3 (2 liters)
Lighting

• Mounting accessories: several accessories in different material • Ex Standards: EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
such as zinc plated steel, galvanized steel or 316 stainless steel • Product Standards: EN / IEC 60598-1; 60598-2-22
• EMC Standards: EN / IEC 55015; 61547
Options • Other Standards: EN / IEC 60529 (IP); 62262 (IK)
• 3 lamp versions.
• 8 W fluorescent (Bi-pin G5) available, see section HBDC series.

1262 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/68

Ordering Information
Order using catalog numbering guide below or select catalog number from tables on following pages.

Catalog Numbering Guide For Fd Non-Metallic Fluorescent Lighting Fixtures


FD B 1 18 BK P A

Series: Number of Lamps: Voltage (50/60 Hz): Options:


FD - FD Series 1 - Single Standard versions: (Options must be
Zone 1 & 2 - 21 & 22 2 - Double AA - 220 Vac 60 Hz listed alphabetically)
ATEX / IEC certified 3 - Three Lamps AC - 230 Vac 60 Hz E - 3h Emergency
XC - 230 Vac 50 Hz (combined) –
X3 - 240 Vac 50 Hz Battery 6 V 4 Ah
BU - 110 to 254 Vac/Vdc

Lighting: Explosionproof — Area — Fluorescent


50/60 Hz

Emergency versions:
BU - 110 to 254 Vac/Vdc
50/60 Hz
Lamp Type: Wattage: Cable Entry:
B - Bi-pin (G13) Fluorescent 18 - 18 Watt M - Metric M20
C - Compact Fluorescent (2G11) 36 - 36 Watt N - NPT 3/4"
F - Bi-pin (G5) Fluorescent 58 - 58 Watt

T Rating (Gas) and Surface Temperature (Dust) Table


Gas – T Rating Dust – Surface Temperature
Without External Reflector With External Reflector Without With
Ta = Ta = Ta = Ta = Ta = External External
Model Lamp Type 104° F/40° C 131 °F/55 °C 158 °F/70 °C 104 °F/40 °C 131 °F/55 °C Reflector Reflector
Compact Fluorescent 2G11
0.3 T6 T5 N.A. T5 T4 203 °F/95 °C 266 °F/130 °C
18 W max.
a) Fluorescent G13
Magnetic Ballast T6 T5 T4 T6 T5 207 °F/97 °C 203 °F/95 °C

Lighting
1 x 18 W / 2 x 18 W
b) Fluorescent G13
0.6 Electronic Ballast T6 T6 N.A. T6 T5 172 °F/78 °C 203 °F/95 °C
1 x 18 W / 2 x 18 W / 3 x 18 W
c) Compact Fluorescent 2G11
T6
1 x 36 W T6 T5 N.A. T4 203 °F/95 °C 266 °F/130 °C
T5
2 x 36 W
a) Fluorescent G13
Magnetic Ballast T6 T5 T4 T6 T5 230 °F/110 °C 203 °F/95 °C
1 x 36 W / 2 x 36 W / 3 x 36 W
1.2
b) Fluorescent G13
Electronic Ballast T6 T6 N.A. T6 T6 172 °F/78 °C 176 °F/80 °C
1 x 36 W / 2 x 36 W / 3 x 36 W
a) Fluorescent G13
Magnetic Ballast T6 T6 N.A. T6 T5 176 °F/80 °C 203 °F/95 °C
1 x 58 W / 2 x 58 W
1.5
b) Fluorescent G13
Electronic Ballast T6 T5 N.A. T6 T5 183 °F/84 °C 203 °F/95 °C
1 x 58 W / 2 x 58 W / 3 x 58 W

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1263


© September 2010
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/68

Ordering Information – Standard Versions


Two M20 threaded entries, supplied with one M20 aluminum blanking plug. L
Connection via 1 x 3 double deck terminals. L
N N

Capacity (flexible/solid): 0.001 in2 to 0.004 in2 / 0.75 mm2 to 2.5 mm2.
For Bi-pin (G13) Fluorescent Lamps - T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
230 V - 50 Hz – Magnetic Ballast – Starter Ignition L
N
Compensated power supply – power factor > 0.9
No. of Power Gas Weight Volume Catalog
Lamps (W) Group Model (lbs/kg) (in3/dm3) Pack Number
1 18 IIC 0.6 19.8/9 3539.38/58 1 FDB118XCM
2 18 IIC 0.6 21.38/9.7 3539.38/58 1 FDB218XCM
Lighting: Explosionproof — Area — Fluorescent

1 36 IIB+H2 1.2 32.41/14.7 6041.35/99 1 FDB136XCM


2 36 IIB+H2 1.2 33.73/15.3 6041.35/99 1 FDB236XCM
1 58 IIB 1.5 37.48/17 7261.83/119 1 FDB158XCM
2 58 IIB 1.5 40.12/18.2 7261.83/119 1 FDB258XCM
240 V - 50 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9
1 18 IIC 0.6 19.8/9 3539.38/58 1 FDB118X3M
2 18 IIC 0.6 21.38/9.7 3539.38/58 1 FDB218X3M
1 36 IIB+H2 1.2 32.41/14.7 6041.35/99 1 FDB136X3M
2 36 IIB+H2 1.2 33.73/15.3 6041.35/99 1 FDB236X3M
1 58 IIB 1.5 37.48/17 7261.83/119 1 FDB158X3M
2 58 IIB 1.5 40.12/18.2 7261.83/119 1 FDB258X3M
220 V - 60 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9
2 18 IIC 0.6 21.38/9.7 3539.38/58 1 FDB218AAM
2 36 IIB+H2 1.2 33.73/15.3 6041.35/99 1 FDB236AAM
2 58 IIB 1.5 40.12/18.2 7261.83/119 1 FDB258AAM
Lighting

230 V - 60 Hz – Magnetic Ballast – Starter Ignition


Compensated power supply – power factor > 0.9
2 18 IIC 0.6 21.38/9.7 3539.38/58 1 FDB218ACM
2 36 IIB+H2 1.2 33.73/15.3 6041.35/99 1 FDB236ACM
2 58 IIB 1.5 40.12/18.2 7261.83/119 1 FDB258ACM

1264 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/68

Ordering Information – Standard Versions – Continued L


N
L
N

For Bi-pin (G13) Fluorescent Lamps - T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
110 to 254 Vac/Vdc 50/60 Hz – Electronic Ballast L
Power factor > 0.95 N

No. of Power Gas Weight Volume Catalog


Lamps (W) Group Model (lbs/kg) (in3/dm3) Pack Number
2 18 IIC 0.6 21.38/9.7 3539.38/58 1 FDB218BUM
2 36 IIB 1.2 33.73/15.3 6041.35/99 1 FDB236BUM
3 36 IIB 1.2 35.94/16.3 6041.35/99 1 FDB336BUM
1 58 IIB 1.5 37.48/17 7261.83/119 1 FDB158BUM

Lighting: Explosionproof — Area — Fluorescent


2 58 IIB 1.5 40.12/18.2 7261.83/119 1 FDB258BUM
3 58 IIB 1.5 42.33/19.2 7261.83/119 1 FDB358BUM
For 2G11 Compact Fluorescent Lamps – TC-L
230 V - 50 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9 – Lamps supplied
1 18 IIC 0.3 19.8/9 3539.38/58 1 FDC118XCM
2 18 IIC 0.3 21.38/9.7 3539.38/58 1 FDC218XCM
1 36 IIB+H2 0.6 32.41/14.7 6041.35/99 1 FDC136XCM
2 36 IIB+H2 0.6 33.73/15.3 6041.35/99 1 FDC236XCM

Emergency Versions
Two M20 threaded entries, supplied with one M20 aluminum blanking plug.
Connection via 1 x 4 double deck terminals.
Capacity (flexible/solid): 0.001 in2 to 0.004 in2 / 0.75 mm2 to 2.5 mm2.

For Bi-pin (G13) Fluorescent Lamps – T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
110 to 254 Vac/Vdc 50/60 Hz – Electronic Ballast
3 hour duration - battery pack 6 V 4 Ah - Power factor > 0.95 -
Self test every month.

Lighting
No. of Power Gas Line Weight Volume Catalog
Lamps (W) Group Model Output (lbs/kg) (in3/dm3) Pack Number
2 18 IIC 0.6 29% 25.57/11.6 3539.38/58 1 FDB218BUME
2 36 IIB 1.2 16% 37.92/17.2 6041.35/99 1 FDB236BUME
2 58 IIB 1.5 11% 44.53/20.2 7261.83/119 1 FDB258BUME

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1265


© September 2010
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/68

Description Pack Catalog Number


External Reflector – White Painted Galvanized Steel
Model 0.3 1 FDER1G
Model 0.6 1 FDER2G
Model 1.2 1 FDER3G
Model 1.5 1 FDER4G
Protective Guard – Zinc Plated Steel
Model 0.3 1 FDPG1Z
Model 0.6 1 FDPG2Z
Model 1.2 1 FDPG3Z
Lighting: Explosionproof — Area — Fluorescent

Model 1.5 1 FDPG4Z


Fixing Brackets for Ease of Surface Installation – Set of Two
Zinc plated steel 1 FDFBZ

316 stainless steel 1 FDFBS

Surface Mounting Brackets – Set of Two


Zinc plated steel 1 FDSBZ

316 stainless steel 1 FDSBS

Half Clamp Brackets for Pole Mounting – Set of Two


Dia. 1.65 to 1.93" / 42 to 49 mm pole
(1.25 to 1.5" / 31.8 to 38.1 mm tube)
Zinc plated steel 1 FDHC49Z
316 stainless steel 1 FDHC49S
Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Zinc plated steel 1 FDHC60Z
316 stainless steel 1 FDHC60S
Lighting

Fall Prevention Kit


1.20 M stainless steel chain 1 FDSCS

1266 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
FD Series Cylindrical Fluorescent Luminaire Technical Data
Standard and Emergency Battery Back-Up – Flameproof

Zone 1 & 2 – 21 & 22


II 2 GD
ATEX / IECEx
IP66/68

Wiring Diagram Emergency Function Diagram


Mains Two Lamp Version
PE N L
Mains Lighting Switch ON Lighting Switch OFF
Lighting
Switch
ON
L1

L OFF
Standard Fluorescent
N Lighting Fixture
PE

Lighting: Explosionproof — Area — Fluorescent


L1
L Emergency Fluorescent
N Lighting Fixture
PE

LED Status

Color Indication Function


Blinking 1:1 Mains good, battery quick charging
Green
ON Mains good, battery trickle charging
Blinking 1:1 No battery connected or something is defective
Flashing 1:1 Mains faulty, battery empty or lamp defective
Red
ON Mains faulty, output ON
OFF No mains, battery completely empty

Lighting
Blinking 1:1 Mains good, performing self test
Yellow
ON Result of self test was not good

Dimensions (in/mm)

0.47”/ 3.05”/ Model A B


12.0 mm 77.5mm
0.3 16.93" / 430 mm 13.19" / 335 mm
0.6 29.33" / 745 mm 25.59" / 650 mm
0.59”/ 1.2 53.74" / 1365 mm 49.61" / 1260 mm
15.0 mm
1.5 65.16" / 1655 mm 61.42" / 1560 mm

3.50”/ 3.35”/
89.0 mm 85.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1267


© September 2010
FD Series Cylindrical Fluorescent Luminaire Photometric Data
Standard and Emergency Battery Back-Up – Flameproof

Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal
Luminaire symbol according to NF C 71-121 Transverse

Bi-pin (G13) Fluorescent 2G11 Compact Fluorescent


1 x 18 W 2 x 18 W 3 x 18 W 2 x 18 W
Efficiency 75.3% Efficiency 68.1% Efficiency 57% Efficiency 56.2%
NF C 71-121/0: 0.69 H + 0.06 T NF C 71-121: 0.63 G + 0.06 T NF C 71-121: 0.50 G + 0.07 T NF C 71-121: 0.52 G + 0.04 T
Candela Candela Candela Candela
Distribution Distribution Distribution Distribution
0-180 90-270 150° 120° 0-180 90-270 150° 120° 0-180 90-270 165° 135° 120° 0-180 90-270 150° 120°
0 167 167 105° 0 161 161 105° 0 141 141 0 154 154 105°
Degrees
5
Degrees
166 167 5 160 162 5
Degrees
141 141 105° 5 Degrees
153 154
10 164 168 90° 10 157 163 90° 10 141 139 10 151 154 90°
90°
Lighting: Explosionproof — Area — Fluorescent

15 160 168 75° 15 153 164 75° 15 140 135 15 147 153 75°
20 154 168 20 148 164 20 139 130 75° 20 142 153
25 147 168 60° 25 141 164 60° 25 138 124 25 136 152 60°
60°
30 139 167 30 133 164 30 136 117 30 128 150
35 129 166 45° 35 123 163 45° 35 133 109 35 119 147 45°
40 118 164 40 112 130 40 128 100 45° 40 108 142
45 151 162 45 100 153 45 121 89 45 95 143
50 106 160 50 86 147 50 113 77 50 81 127
55 77 157 30° 55 73 141 30° 55 105 65 55 66 113 30°
30°
60 61 152 60 58 134 60 96 51 60 49 101
65 45 144 0° 15° 65 41 121 0° 15° 65 87 38 0° 15° 65 32 88 0° 15°
70 28 135 70 26 106 70 78 25 70 17 75

1 x 36 W 2 x 36 W 3 x 36 W 2 x 36 W
Efficiency 74.3% Efficiency 61.5% Efficiency 53.3% Efficiency 53.6%
NF C 71-121/0: 0.69 H + 0.05 T NF C 71-121: 0.57 G + 0.04 T NF C 71-121: 0.47 G + 0.06 T NF C 71-121: 0.50 G + 0.04 T
Candela Candela Candela Candela
Distribution Distribution Distribution Distribution
0-180 90-270 150° 120°
0-180 90-270 150° 120°
0-180 90-270 165° 135° 120° 0-180 90-270 150° 120°
0 164 164 105° 0 149 149 105° 0 132 132 0 140 140 105°
5 163
Degrees
164 5 Degrees
148 149 5
Degrees
132 131 105° 5
Degrees
139 141
10 161 165 90° 10 146 150 90° 10 132 129 10 137 141 90°
90°
15 157 165 75° 15 142 150 75° 15 131 126 15 134 142 75°
75°
20 151 165 20 137 150 20 131 122 20 129 141
25 145 165 60° 25 131 149 60° 25 131 116 25 124 140 60°
60°
30 137 165 30 124 148 30 128 110 30 117 139
35 127 164 45° 35 114 146 45° 35 125 102 35 109 137 45°
40 116 162 40 104 144 40 120 93 45° 40 99 132
45 104 160 45 93 138 45 114 83 45 89 125
50 91 158 50 81 131 50 107 72 50 77 117
Lighting

55 76 154 30° 55 68 125 30° 55 99 61 55 65 108 30°


30°
60 61 149 60 54 117 60 91 49 60 52 97
65 45 140 0° 15° 65 40 105 0° 15° 65 82 36 0° 15° 65 38 87 0° 15°
70 30 131 70 26 91 70 74 24 70 24 75

1 x 58 W 2 x 36 W 3 x 36 W
Efficiency 74.5% Efficiency 61.5% Efficiency 53.3%
NF C 71-121/0: 0.70 H + 0.05 T NF C 71-121: 0.57 G + 0.04 T NF C 71-121: 0.47 G + 0.06 T
Candela Candela Candela
Distribution Distribution Distribution
0-180 90-270 0-180 90-270 0-180 90-270
0 167 167 150° 120° 0 148 148 150° 120° 0 125 125 165° 135° 120°
5 167 167 105° 5 147 149 105° 5 125 125
Degrees Degrees Degrees 105°
10 164 167 10 145 148 10 125 124
90° 90° 90°
15 160 167 15 142 149 15 124 122
75° 75° 75°
20 154 167 20 137 150 20 123 119
25 147 166 60° 25 131 149 60° 25 121 114 60°
30 139 165 30 124 148 30 118 108
35 130 164 45° 35 115 146 45° 35 115 101
45°
40 119 163 40 105 144 40 109 92
45 106 161 45 94 140 45 103 82
50 93 158 30°
50 82 134 30°
50 96 72
55 78 155 55 69 128 55 89 60 30°
60 63 149 0° 15°
60 55 119 0° 15°
60 81 48 0° 15°
65 47 142 65 42 108 65 73 36
70 31 132 70 28 95 70 65 24

1268 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC: CEC: V Type 3R, 4X


Class I, Division 1, Groups C, D Class I, Division 1 and 2, Groups B, C, D. T3B
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB, IIA
Class III Exd IIB + H2, Zone 1
NEMA 3R, 4X Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Applications
• Code•Master Incandescent Explosionproof fixtures are
designed to provide safe operation in the presence of hazardous
gases, vapors, or dusts, defined by the National Electrical Code
as Class I, Groups C and D; Class I, Zone 1, Group IIB; and
Class II, Groups E, F and G.
• For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured.
• For use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners, in refineries,
and in other areas where ignitable vapors, dust, moisture and
corrosive elements may be present.
• Suitable for outdoor saltwater locations and for other
wet locations.
Features
• Fixtures operate safely in high ambient temperatures.
• Patented “wireless” design. Threading of fixture unit
onto mounting hood makes electrical connection. The
only wiring required is attaching two wires to connection
block in mounting hood.
• Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) re-position connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.

Lighting: Explosionproof — Area — Incandescent


• Acme double-lead threads speed installation and fixture removal
from mounting hood – only half as many turns are required
Standard Materials
as for single-lead threads. The threads do not stick or gall, • Fixture housing, mounting hoods and guards: copperfree
eliminating problems often encountered with single-lead threads (4/10 of 1% max.) aluminum
during fixture unit removal. • Globes: prismatic glass
• Strategic location of lamp socket, in combination with interior • Reflectors: fiberglass reinforced polyester
prism design of the glass globe, provides optimum light Standard Finishes
distribution and control.
• Fixture housing, guards and mounting hoods: epoxy power
• Heat- and impact-resistant globes have smooth
coat finish, electrostatically applied for complete, uniform
dust-resistant exterior.
corrosion protection
• Superior corrosion resistance, with epoxy powder coat finish.
• Porcelain socket with nickel-plated phosphor bronze screw Options
shell. Assures long trouble-free operation in high ambient areas. • Add suffix -Z for Exd IIB + H2, Zone 1 V.
• Choice of mountings: pendant, ceiling, bracket and stanchion.
• Fiberglass-reinforced polyester reflectors, in standard dome Certifications and Compliances
or 30° angle styles, are ideal in installations where luminaire is • UL Standard: UL 1598, UL 1598A, UL 844
subject to exceptionally severe corrosive atmospheres. • UL Listed: E10444
• All threaded joints are flame-tight.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Optional guards protect globes from damage. Secured to fixture
with three stainless steel screws.
• Medium base lamp socket.
• Maximum voltage 300 Vac 60 Hz.
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1269


© September 2010
Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC: CEC: V Class III


Class I, Division 1, Groups C, D Class I, Division 1 and 2, Groups B, C, D. T3B Type 3R, 4X
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB, IIA
Class III Exd IIB + H2, Zone 1
NEMA 3R, 4X Class II, Division 1 and 2, Groups E, F, G. T3B

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
CI P 30 75 G

Series: Wattage: Options:


CI – Code•Master Incandescent 30 – 100 W A21 G – Guard
200 W A23 Blank – No Guard
300 W PS25 Z - Exd IIB + H2, Zone 1 V

Mounting Hood: Hub Size:


P – Pendant 75 – 3/4”
B – Wall Bracket 100 – 1”
C – Ceiling 150 – 1-1/4” or 1-1/2”
S – Stanchion
Lighting: Explosionproof — Area — Incandescent

Technical Data Thermal Suitability of Code•Master Incandescent Fixture.


Ambient
Lamp Watts Use Wire Supply Class I, Division 1, Class II, Division 1,
Lamp Type Temperature
(Max.) °F/°C Groups C & D Groups E, F & G
°F/°C
Incandescent (A21) 100 167/75 104/40 T5 T3C
Incandescent (A23) 200 167/75 104/40 T4 T3C
Incandescent (PS25) 300 167/75 104/40 T3C T3C

“T” Numbers Represent the Maximum External Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3 T4 T4A T5 T6
Number
Temp
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(°F)
Temp
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)
Lighting

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code..

V CSA Certification only.

1270 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC: CEC: V Type 3R, 4X


Class I, Division 1, Groups C, D Class I, Division 1 and 2, Groups B, C, D. T3B
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB, IIA
Class III Exd IIB + H2, Zone 1
NEMA 3R, 4X Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Type Mounting Hub Size (Inches) Catalog Number ➌


Pendant

3/4 CIP3075
One Hub
Rigid Conduit.
1 CIP30100 ➋

Ceiling

3/4 CIC3075
Four Hubs
Three Close-Up Plugs
Rigid Conduit
1 CIC30100 ➋

Wall Bracket

3/4 CIB3075
Four Hubs
Three Close-Up Plugs
Rigid Conduit
1 CIB30100 ➋

25° Stanchion

Lighting: Explosionproof — Area — Incandescent


One Hub 1-1/2 ♦ CIS30150

Mounting Hoods
Type Mounting Hub Size (Inches) Hood Weight (Lbs.) Catalog Number
Pendant
3/4 2/.9 CAP75
One Hub
Rigid Conduit
1 2/.9 CAP100 ➋
Ceiling
Four Hubs 3/4 4/1.8 CAC75
Three Close-Up Plugs
Rigid Conduit 1 4/1.8 CAC100 ➋
Bracket

Four Hubs 3/4 6/2.7 CALB75


Lighting

Three Close-Up Plugs


Rigid Conduit 1 6/2.7 CALB100 ➋

25° Stanchion

One Hub 1-1/4 or 1-1/2 ➊ 2/.9 CAS-150 ➊

➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.


➋ 1” Hubs are listed for Group D only.
➌ Catalog numbers shown are supplied with clear lens. Add suffix G for optional Guard.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1271


© September 2010
Code•Master™ Incandescent Factory Sealed Luminaire Fixture Units and Accessories
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC: CEC: V Type 3R, 4X


Class I, Division 1, Groups C, D Class I, Division 1 and 2, Groups B, C, D. T3B
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB, IIA
Class III Exd IIB + H2, Zone 1
NEMA 3R, 4X Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Description Weight lbs/kg Catalog Number


Fixture Unit Only

Not including mounting CJNC30I


11/5
hood

Optional White Polyester Reflector

Standard Dome 2.5/1.1 KR2-ST

Optional White Polyester Reflector

Angled Reflector 2.5/1.1 KR2-AN

Optional Aluminum Guard


Lighting: Explosionproof — Area — Incandescent

0.5/.2 CJGU-15

Optional Three Way Exit Sign

7.5/3.4 CJEXRN

Replacement Connection Block

0.5/.2 VPT-7
Lighting

1272 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ Incandescent Factory Sealed Luminaire Family Tree and Dimensions
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC: CEC: V Type 3R, 4X


Class I, Division 1, Groups C, D Class I, Division 1 and 2, Groups B, C, D. T3B
Class II, Division 1 and 2, Groups E, F, G Class I, Zone 1 and 2, Groups IIB, IIA
Class III Exd IIB + H2, Zone 1
NEMA 3R, 4X Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Ceiling Bracket
Pendant Four Hubs Four Hubs 25° Stanchion
One Hub Three Close-Up Plugs Three Close-Up Plugs One Hub
3/4” NPT 3/4” NPT 3/4” NPT 1-1/4 or 1-1/2” NPT
CAP75 CAC75 CALB75 CAS150

Code•Master
Incandescent
Standard Dome Fixture Unit Angle Reflector
KR2-ST CJNC30I KR2-AN

Optional Aluminum Optional Three Way

Lighting: Explosionproof — Area — Incandescent


Guard Exit Sign
CJGU-15 CJEXRN

Dimensions in Inches/Millimeters

Hub for .75" Pendant


NPT Conduit 13.88"/
4.50"/ 352.6 mm
114.3 mm
Wall Bracket 4.92"/
3.75"/
95.3 mm 125.0 mm
12.38"/
Hub For 314.5 mm
0.41"/ 3/4” NPT
10.4 mm Dia. 2” Wiring access
2.46"/ 2.28"/
62.5 mm 57.9 mm
cover both sides. 13.75"/
13.15"/ 349.3 mm
334.0 mm 4.25"/
4.92"/
125.0 mm Sq. 108.0 mm

13.53"/ 3.92"/
1.23"/
31.2 mm 1.79"/
343.7 mm 99.6 mm
3.46"/
45.5 mm
87.9 mm 11.5"/
292.1 mm 7.80"/
13.75"/ 198.1 mm
349.3 mm

Ceiling 25° Stanchion


5.95"/
151.3 mm 25˚

7.80"/
198.1 mm 4.00"/
101.6 mm Hub for .75" NPT
Conduit Four Sides
Lighting

11.93"/
303.0 mm
13.00"/
13.38"/ 330.2 mm
339.9 mm 12.87"/
4.00"/ 326.9 mm
101.6 mm
4.50"/
114.3 mm
Dia.
4.00"/
101.6 mm

5.92"/
150.4 mm
11.43"/
7.80"/ 290.3 mm
12.48"/
198.1 mm 317.0 mm

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1273


© September 2010
A-51® Incandescent Factory Sealed Luminaires
Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

For Group A and B For Group C and D


Class I, Division 1 and 2, Groups A , B, C, D Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G Class II, Division 1 and 2, Groups E, F, G*
Class III Class III

Applications Group A and B


• A-51 Series Incandescent Class I, Groups A, B, C and D; and
Class II, Groups E, F and G applications (see listings and area
suitability chart).
• Ideal for use in chemical and petrochemical plants, and in other
heavy process areas where ignitable vapors, dust, moisture and
corrosive atmospheres may be present.
• Suitable for use in wet locations.
• Wide range of wattages – 60 W through 500 W
incandescent lamps.
• Choice of units with or without guard, as well as choice of
porcelain, polyester or aluminum reflectors. Polyester Reflector Porcelain Reflector
• Choice of mountings: pendant, ceiling, 25° stanchion, long
bracket and 15° short bracket.
• Porcelain reflectors for standard applications and fiberglass
reinforced polyester reflectors for installations where fixture is
subject to exceptionally severe corrosive atmospheres. High
bay reflector for installations where mounting height from work
plane ranges from 20 to 30 feet/508" to 762 mm. Group C and D
• Class I, Groups A and B fixtures have special UL-approved
sintered metal flame arrester.
Features
• All A-51 fixtures are factory-sealed; no external sealing
fittings required.
• New high temperature phenolic connection block in mounting
Lighting: Explosionproof — Area — Incandescent

hood has rugged leaf spring contacts – loosen two screws,


rotate and remove for quick wiring.
• Safe, easy servicing or relamping without disconnecting any Polyester Reflector Porcelain Reflector
wiring. “Wireless” fixture unit easily threads off mounting hood
for convenient servicing or for immediate exchange with “stand-
by” unit.
• All joints are flame-tight.
• Specially formulated two-coat baked epoxy enamel provides
superior protective finish to resist corrosion. Applied to all
mounting hoods, fixture units and guards.
• New high temperature glass-reinforced phenolic socket
block in fixture unit has collector ring and pin that automatically Standard Finishes
make electrical contact as fixture unit is threaded onto • Fixtures, guards and mounting hoods: two-coat epoxy-clad
mounting hood. finish. Epoxy powder coat finish, electrostatically applied for
• Globes in A-51 fixtures are explosionproof and heat- and complete, uniform surface protection.
impact-resistant glass. Prismatic configuration on globe • Steel reflectors: white porcelain enamel.
interior provides light control while allowing smooth exterior • Polyester and aluminum reflectors: natural finish.
surface for cleaning.
• A-51 fixture units have standardized threads to fit all A-51 Certifications and Compliances
and mounting hoods. • UL Standard: UL 1598, UL 844
• All fixtures have aluminum inner reflector for increased lumen • UL Listed: E10444
efficiency. • CSA Standard: C22.2 No. 250, C22.2 No. 137
• A-51 fixture guards to protect globe are of rugged copperfree • CSA Certified: 025428
aluminum construction and double epoxy coated. Easily mount
to globe ring with 3 screws.
Lighting

Standard Materials
• Fixtures and guards: copperfree (4/10 of 1% max.) aluminum.
• Pendant mounting hoods: copperfree (4/10 of 1% max.)
aluminum.
• Ceiling and bracket mounting hoods: malleable iron with
aluminum adapters.
• Reflectors: porcelain-enameled steel, aluminum or fiberglass
reinforced polyester.

1274 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
A-51® Incandescent Factory Sealed Luminaires
Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups A, B, C, D.


Class II, Division 1 and 2, Groups E, F, G
Class III

Weights
Illustrated Features
Fixture Units
Catalog Number Wt. lbs/kgs
AAU-1N 7.6/3.4
AAU-15N 7.6/3.4
AAU-2NS 10.7/4.9
AAU-5NS 20.3/9.2
AAUA-15 15.0/6.8
AAUA-2 18.0/8.2

Mounting Hoods
Type Wt. lbs/kg
Pendant 1.3/.6
Ceiling 4.8/2.2
Stanchion 1.6/.7
Long Bracket 8.9/4.0
Short Bracket 4.8/2.2

Lighting: Explosionproof — Area — Incandescent


Guards
Catalog Number Wt. lbs/kgs
AAGU-1 0.4/.2
AAGU-2 0.8/.4
AAGU-5 1.9/.9
AAGUA-15 0.5/.2

Standard Reflectors
Catalog Number Wt. lbs/kgs
AARP-2ST 2.8/1.3
AARW-15ST 2.1/1.0
AARW-2ST 2.9/1.3
AARW-5ST 4.3/2.0
AARW-15ST 2.1/1.0

30˚° Angle Reflectors


Catalog Number Wt. lbs/kgs
AARP-2AN 3.3/1.5
AARW-15AN 2.1/1.0
Lighting

AARW-2AN 2.4/1.1
AARW-5AN 7.0/3.2
AARW-15AN 2.1/1.0

High Bay Reflectors


Catalog Number Wt. lbs/kgs
AARE-2HB 2.9/1.3
AARE-5HB 3.9/1.8

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1275


© September 2010
A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability
Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups A, B, C, D.


Class II, Division 1 and 2, Groups E, F, G
Class III

Fixture Lamp Without Standard 30°˚ High Supply Wire


Unit Watts Reflectors Dome Angle Bay °F/°C
Class I Division 1 and Division 2 Groups C and D
AAU1N 100 W A19 T5 T5 T5 — 257/125
100 W A21 T5 T5 T5 — 257/125
AAU15N 150 W A23 T3C T3C T3C — 257/125
200 W A25 T3C T3C T3C — 257/125
200 W PS25 T3C T3C T3C — 257/125
300 W PS25 T3C T3A T3A (D) — 257/125
AAU2NS 200 W PS25 T3C T3C T3C — 230/110
200 W PS30 T3C T3C T3C — 230/110
300 W PS25 T3C T3C T3C — 230/110
300 W PS30 T3C T3C T3C — 230/110

Class I Division 1 and Division 2 Groups A †, B, C and D


AAUA15 150 W A23 T3C T3C T3C — 230/110
150 W A25 T3C T3C T3C — 230/110
Lighting: Explosionproof — Area — Incandescent

200 W A25 T3C T3C T3C — 230/110


200 W PS25 T3C T3C T3C — 230/110
AAUA2 200 W PS25 T3C T3C T3C — 230/110
200 W PS30 T3C T3C T3C — 230/110
300 W PS25 T3C T3C T3C — 230/110
300 W PS30 T3C T3C T3C — 230/110

Class II Division 1 and Division 2 Groups E, F and G


AAU1N 100 W A19 T3C T3C T3C — 257/125
100 W A21 T3C T3C T3C — 257/125
AAU15N 150 W A23 T3C T3C T3C — 257/125
200 W A25 T3C T3C T3C — 257/125
200 W PS25 T3 T3 T3 — 257/125
300 W PS25 T3 — — — 257/125
AAU2NS 200 W PS25 T3C T3C T3C — 230/110
200 W PS30 T3C T3C T3C — 230/110
300 W PS25 T3C T3C T3A (EF) — 230/110
Lighting

300 W PS30 T3C T3C T3A (EF) — 230/110

NOTE: Ambient suitability of these incandescent fixtures: 104°F/40 °C


† For Group A, use Pendant Mount only.

1276 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
A-51® Incandescent Factory Sealed Luminaires
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Hub Size Catalog


Type (Inches) Number ➋
Pendant — One Hub, Rigid or Flexible Mounting
60-100 W (AAU-1N) 1/2 AP1050
A-21 3/4 AP1075
1 AP10100
150-300 W (AAU-15N) 1/2 AP1550
A-23 PS-25 3/4 AP1575
1 AP15100
200-300 W (AAU-2NS) 1/2 AP2050
PS-30 3/4 AP2075
1 AP20100

Ceiling — Four Hubs, Three Close-up Plugs


60-100 W (AAU-1N) 1/2 AC1050
A-21

Lighting: Explosionproof — Area — Incandescent


3/4 AC1075
1 AC10100
150-300 W (AAU-15N) 1/2 AC1550
A-23 PS-25 3/4 AC1575
1 AC15100
200-300 W (AAU-2NS) 1/2 AC2050
PS-30 3/4 AC2075
1 AC20100

25° Stanchion — One Hub — Not UL Listed


60-100 W (AAU-1N)
1-1/2 ➋ AN10150
A-21
150-300 W (AAU-15N)
1-1/2 ➋ AN15150
A-23 PS-25
200-300 W (AAU-2NS)
1-1/2 ➋ AN20150
PS-30
Lighting

➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.
➋ 1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1277


© September 2010
A-51® Incandescent Factory Sealed Luminaires
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Hub Size Catalog


Type (Inches) Number ➋
Long Bracket — Four Hubs, Three Close-up Plugs
60-100 W (AAU-1N) 1/2 ALB1050
A-21 3/4 ALB1075
1 ALB10100
150-300 W (AAU-15N) 1/2 ALB1550
A-23 PS-25 3/4 ALB1575
1 ALB15100
200-300 W (AAU-2NS) 1/2 ALB2050
PS-30 3/4 ALB2075
1 ALB20100

15° Short Bracket — Two Hubs, One Close-up Plug


60-100 W (AAU-1N) 1/2 ASB1050
A-21 3/4 ASB1075
150-300 W (AAU-15N) 1/2 ASB1550
A-23 PS-25
Lighting: Explosionproof — Area — Incandescent

3/4 ASB1575

200-300 W (AAU-2NS) 1/2 ASB2050


PS-30
3/4 ASB2075

Three-Way Exit Sign

Epoxy enameled steel – 6”/152.4 mm-high red lettering 60-200 W


CJEXRN
(Mounts to AAU-1N or AAU-15N fixture units in place of guard)

Single-Sided Exit Sign

Epoxy enameled steel – 6”/152.4 mm-high red lettering 60-200 W


(Mounts to AAU-1N or AAU-15N fixture units in place of guard) AEXR-15R
(See page G2-24 for dimensions)

Guard — Add suffix to fixture catalog number


Lighting

Guard -G

➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.

1278 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
A-51® Incandescent Factory Sealed Luminaire Accessories
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Mounting Hoods
Type Hub Size (Inches) Catalog Number
Pendant — One Hub, Rigid or Flexible Mounting
1/2 AAP-50
3/4 AAP-75
1 AAP-100
Ceiling — Four Hubs, Three Close-up Plugs
1/2 AAC-50
3/4 AAC-75
1 AAC-100

25° Stanchion — Not UL Listed — One Hub


1-1/2 AAN-150 ➊

Long Bracket — Four Hubs, Three Close-up Plugs


1/2 AALB-50
3/4 AALB-75

Lighting: Explosionproof — Area — Incandescent


1 AALB-100

15˚ Short Bracket — Two Hubs, One Close-up Plug


1/2 AASB-50
3/4 AASB-75

Type Catalog Number


Fixture Units
60-100 W A-21 AAU-1N
150-300 W A-23 & PS-25 AAU-15N
200-300 W PS-30 AAU-2NS

Prismatic Glass Globes


60-100 W (AAU-1N) AAGL-1PR
150-300 W (AAU-15N) AAGL-1PR
200-300 W (AAU-2NS) AAGL-2PR
Lighting

Aluminum Guards
60-100 W (AAU-1N) AAGU-1
150-300 W (AAU-15N) AAGU-1
200-300 W (AAU-2NS) AAGU-2
300-500 W (AAU-5NS) AAGU-5

➊ 1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1279


© September 2010
A-51® Incandescent Factory Sealed Luminaire Accessories
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Type Fixture Size Catalog Number


Standard Dome
(Not for use with short brackets) Porcelain Polyester
60-100 W (AAU-1N) AARW-15ST —
150-300 W (AAU-15N) AARW-15ST —
200-300 W (AAU-2NS) AARW-2ST AARP-2ST
Porcelain Polyester 300-500 W (AAU-5NS) AARW-5ST —

30˚ Angle
60-100 W (AAU-1N) AARW-15AN —
150-300 W (AAU-15N) AARW-15AN —
200-300 W (AAU-2NS) AARW-2AN AARP-2AN

Porcelain Polyester

Colored Glass Globes


Amber
60-100 W (AAU-1N) AAGL-1A
150-300 W (AAU-15N) AAGL-1A
200-300 W (AAU-2NS) AAGL-2A
Lighting: Explosionproof — Area — Incandescent

Green
60-100 W (AAU-1N) AAGL-1G
150-300 W (AAU-15N) AAGL-1G
200-300 W (AAU-2NS) AAGL-2G
Red
60-100 W (AAU-1N) AAGL-1R
150-300 W (AAU-15N) AAGL-1R
200-300 W (AAU-2NS) AAGL-2R
Replacement Socket
60-100 W (AAU-1N) — Medium Base AASP-11
150-300 W (AAU-15N) — Medium Base AASP-22
200-300 W (AAU-2NS) — Medium Base AASP-22
300-500 W (AAU-5NS) — Mogul Base AASP-44

Connection Block
Fits A-51 Mounting Hoods
60-500 W VPT-7

Globe Gaskets — Fiber and Aluminum


Lighting

Requires one of each Fiber Aluminum


60-300 W (AAU-1N and AAU-15N) AASP-15V AASP-15A
200-300 W (AAU-2NS) AASP-2V AASP-2A
300-500 W (AAU-NS) AASP-5V AASP-5A

1280 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
A-51® Incandescent Factory Sealed Luminaire Dimensions
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

3.38"/
85.9 mm 4.75"/
120.7 mm

5.38"/
116.7 mm .38"/ 2.69"/
9.7 mm 68.3 mm 2.63"/
.38"/ 66.8 mm
4.69"/ 9.7 mm
119.1 mm

5.75"/ 1.31"/
146.1 mm 33.3 mm

Stanchion Pendant ➊ Ceiling Long Bracket Short Bracket


Size (Watts) A B C A B C A B C A B C A B C
11.47/ 10.85/ 11.50/ 12.25/ 11.63/ 7.06/ 13.75/ 13.13/ 7.06/ 13.75/ 13.13/ 12.38/ 13.56/ 12.94/ 9.13/
60-100
291.3 275.6 292.1 311.2 295.4 179.3 349.3 333.5 179.3 349.3 333.5 314.5 344.4 328.7 231.9
11.47/ 10.85/ 11.50/ 12.25/ 11.63/ 7.06/ 13.75/ 13.13/ 7.06/ 13.75/ 13.13/ 12.38/ 13.56/ 12.94/ 9.13/
150-300
291.3 275.6 292.1 311.2 295.4 179.3 349.3 333.5 179.3 349.3 333.5 314.5 344.4 328.7 231.9
13.07/ 12.38/ 12.71/ 13.94/ 13.25/ 8.81/ 15.44/ 14.75/ 8.81/ 15.50/ 14.75/ 13.25/ 15.19/ 14.50/ 10.13/
200-300

Lighting: Explosionproof — Area — Incandescent


332.0 314.5 322.8 354.1 336.6 223.8 392.2 374.7 223.8 392.2 374.7 336.6 385.8 363.8 257.3
15.09/ 14.34/ 14.64/ 16.00/ 15.25/ 12.13/ 17.50/ 17.75/ 12.13/ 17.50/ 16.75/ 14.88/ 17.25/ 16.50/ 11.94/
300-500
383.3 364.2 371.8 406.4 387.4 308.1 444.5 450.9 308.1 444.5 425.9 378.0 438.2 419.1 303.3

Size (Watts) A➋ B➋ A B A B
60-100 12.00/304.8 4.50/114.3 10.00/254.0 7.63/193.8 - -
150-200 14.00/355.6 4.38/111.3 10.00/254.0 7.63/193.8 - -
200-300 16.00/406.4 5.19/131.8 12.00/304.8 7.88/200.2 12.00/304.8 6.06/153.9
300-500 20.00/508.0 6.84/173.7 18.00/457.2 13.13/333.5 18.00/457.2 9.13/231.9

Lighting

➊ For dimensions of fixture unit only, subtract pendant hood dimension 1.31”/3.3 cm from dimensions A and B as listed.
➋ Dimensions illustrated are for porcelain steel (dome and angle) and etched aluminum (high bay).
Overall dimensions for fiberglass reinforced polyester reflectors are: standard dome – 16-1/2”/419.1 mm dia., 6” high; 30° Angle – 14-3/8”/374.7 mm dia.,
10”/254 mm high.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1281


© September 2010
A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Photometric data shown here is based on a 200- 60 W A-19 – 0.23; 100 W A-19 – 0.47; To determine candlepower values of fixtures with a
watt type PS-30 lamp and is representative of 150 W A-21 – 0.75; 200 W A-23 – 1.07; guard, multiply by value shown with each curve.
the performance for all A-51 incandescent fixtures 200 W A-25 – 1.02; 200 W PS-25 – 1.03:
using 60-watt to 500-watt lamps. For candlepower 300 W PS-25 – 1.70; 300 W PS-30 – 1.63;
values of fixtures with other lamps, use the following 300 W PS-35 – 1.55; 500 W PS-35 – 2.95;
multipliers: 500 W PS-40 – 2.69.

A-51 Incandescent Effective Floor Cavity Reflectance (Rfc) is 20%


Fixture without Reflector
Spacing to Mtg. Ht. % Ceiling Rcc 80 70 50 30 10 0
Ratio 1.25:1 % Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Guard .877
1 .735 .690 .651 .695 .655 .618 .622 .590 .561 .554 .530 .506 .493 .473 .454 .422

2 .621 .558 .503 .588 .530 .481 .525 .478 .437 .467 .430 .396 .413 .384 .357 .327

3 .540 .468 .411 .512 .446 .394 .457 .404 .359 .406 .363 .327 .360 .325 .294 .267

ROOM CAVITY RATIOS


4 .474 .400 .342 .450 .381 .328 .402 .346 .301 .359 .312 .274 .318 .280 .248 .223

5 .415 .341 .284 .394 .325 .272 .354 .295 .251 .316 .266 .229 .280 .240 .207 .184

6 .372 .297 .245 .352 .284 .233 .316 .258 .215 .283 .234 .197 .252 .210 .178 .157

7 .334 .262 .213 .317 .249 .203 .285 .227 .187 .255 .207 .170 .228 .187 .155 .136

8 .300 .231 .182 .285 .221 .175 .256 .202 .162 .231 .183 .148 .206 .165 .135 .117

9 .271 .204 .157 .258 .195 .152 .233 .178 .140 .209 .162 .128 .187 .146 .117 .100

10 .246 .181 .139 .234 .175 .135 .212 .160 .124 .191 .145 .113 .172 .132 .102 .087

A-51 Incandescent Fixture with Effective Floor Cavity Reflectance (Rfc) is 20%
Standard Dome Reflector
Lighting: Explosionproof — Area — Incandescent

Spacing to Mtg. Ht. % Ceiling Rcc 80 70 50 30 10 0


Ratio 1.25:1 % Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Guard .890
1 .757 .727 .700 .740 .713 .689 .709 .686 .667 .681 .663 .646 .656 .641 .627 .612

2 .660 .613 .572 .647 .603 .567 .621 .585 .552 .598 .568 .540 .577 .551 .528 .512

3 .580 .524 .478 .570 .516 .475 .549 .504 .466 .529 .490 .458 .511 .478 .449 .434
ROOM CAVITY RATIOS

4 .514 .452 .403 .504 .446 .400 .486 .436 .395 .469 .425 .390 .454 .415 .384 .368

5 .451 .385 .336 .442 .380 .334 .427 .372 .332 .413 .364 .327 .399 .357 .323 .308

6 .402 .336 .291 .394 .333 .286 .381 .326 .285 .369 .319 .282 .358 .313 .279 .264

7 .361 .296 .254 .355 .293 .250 .343 .286 .247 .332 .282 .245 .323 .278 .243 .229

8 .323 .261 .216 .318 .258 .216 .308 .254 .215 .299 .249 .213 .290 .245 .211 .197

9 .291 .230 .187 .287 .227 .187 .278 .223 .186 .269 .219 .184 .262 .216 .182 .169

10 .264 .204 .166 .259 .204 .166 .253 .200 .164 .245 .197 .162 .240 .194 .161 .149
Lighting

1282 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Photometric data shown here is based on a 200- 60 W A-19 – 0.23; 100 W A-19 – 0.47; To determine candlepower values of fixtures with a
watt type PS-30 lamp and is representative of the 150 W A-21 – 0.75; 200 W A-23 – 1.07; guard, multiply by value shown with each curve.
performance for all A-51 incandescent fixtures 200 W A-25 – 1.02; 200 W PS-25 – 1.03:
using 60-watt to 500-watt lamps. For candlepower 300 W PS-25 – 1.70; 300 W PS-30 – 1.63;
values of fixtures with other lamps, use the following 300 W PS-35 – 1.55; 500 W PS-35 – 2.95;
multipliers: 500 W PS-40 – 2.69.

Effective Floor Cavity Reflectance (Rfc) is 20%

% Ceiling Rcc 80 70 50 30 10 0

% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
A-51 Incandescent Fixture
with High Bay Reflector 1 .686 .644 .645 .671 .651 .634 .644 .628 .614 .620 .607 .595 .598 .588 .577 .566
Spacing to Mtg.
Ht. Ratio 1.40:1 2 .614 .580 .549 .603 .571 .545 .581 .555 .531 .562 .540 .520 .544 .525 .508 .496
Guard .865

3 .550 .508 .473 .542 .501 .470 .524 .490 .461 .507 .478 .454 .492 .467 .446 .434

ROOM CAVITY RATIOS


4 .493 .445 .408 .486 .441 .404 .470 .431 .400 .456 .422 .395 .443 .413 .389 .377

5 .439 .387 .349 .432 .383 .347 .420 .376 .344 .407 .369 .340 .396 .383 .336 .324

12.00"/ 6 .393 .340 .304 .387 .338 .300 .376 .331 .298 .366 .326 .296 .356 .320 .293 .281
304.8 mm
7 .352 .299 .264 .347 .296 .261 .337 .290 .258 .327 .287 .256 .320 .283 .254 .242

8 .313 .261 .224 .309 .259 .223 .300 .255 .222 .293 .251 .220 .285 .247 .219 .207

9 .280 .228 .191 .276 .225 .191 .268 .222 .190 .261 .219 .189 .254 .216 .187 .176

10 .252 .201 .168 .248 .201 .168 .242 .197 .167 .236 .195 .165 .231 .192 .164 .153

A-51 Incandescent Fixture


with 30°˚ Reflector

Lighting: Explosionproof — Area — Incandescent


11.16"/
283.5 mm
B—
Back
S—Side
F—Front
G—Front W.Guard

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1283


© September 2010
A-51® Incandescent Factory Sealed Luminaires
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups A, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Hub Size Catalog


(Inches) Number ➊➋
Pendant  — One Hub, Rigid or Flexible Mounting

60-200 W (AAUA-15) 1/2 AAPA1550

PS-25 3/4 AAPA1575

200-300 W (AAUA-2) 1/2 AAPA2050

PS-30 3/4 AAPA2075

Ceiling — Four Hubs, Three Close-up Plugs

60-200 W (AAUA-15) 1/2 AACA1550

PS-25 3/4 AACA1575

200-300 W (AAUA-2) 1/2 AACA2050

PS-30 3/4 AACA2075


Lighting: Explosionproof — Area — Incandescent

15˚ Short Bracket — Two Hubs, One Close-up Plug

60-200 W (AAUA-15) 1/2 AASBA1550

PS-25 3/4 AASBA1575

200-300 W (AAUA-2) 1/2 AASBA2050

PS-30 3/4 AASBA2075

Reflectors
Porcelain Polyester
Standard Dome Porcelain Polyester
60-200 W (AAUA-15) AARW-15ST
200-300 W (AAUA-2) AARW-2ST AARP-2ST

30˚ Angle
60-200 W (AAUA-15) AARW-15AN
200-300 W (AAUA-2) AARW-2AN AARP-2AN
Lighting

➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.
➋ Add suffix -G to catalog number for optional guard.
 Shaded area indicates pendant mount is suitable for Class I, Group A in addition to other applicable area suitabilities.

1284 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
A-51® Incandescent Factory Sealed Luminaires
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups A, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Mounting Hoods

Type Hub Size (Inches) Catalog Number


Pendant
One Hub, 1/2 AAP-50 ➊
Rigid or Flexible Mounting
3/4 AAP-75 ➊

Ceiling
Four Hubs, 1/2 AAC-50
Three Close-up Plugs
3/4 AAC-75

15˚ Short Bracket


Two Hubs, 1/2 AASB-50
One Close-up Plug
3/4 AASB-75

Description Catalog Number


Fixture Units

Lighting: Explosionproof — Area — Incandescent


60-200 W
PS-25 AAUA-15
200-300 W
PS-30 AAUA-2

Globe and Ring Assembly


60-200 W (AAUA-15) AAGLA-15
200-300 W (AAUA-2) AAGLA-2

Aluminum Guards
60-200 W (AAUA-15) AAGUA-15
200-300 W (AAUA-2) AAGU-2

Medium Base Lamp Socket


60-200 W (AAUA-15) AASPA-15
Lighting

200-300 W (AAUA-2) AASPA-22

Connection Block
Fits all A-51 and AA-51 mounting hoods
60-300 W VPT-7

➊ Group A pendant mount only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1285


© September 2010
A-51® Incandescent Factory Sealed Luminaire Dimensions
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Dimensions in In/mm

4.75"/
120.7 mm

3.38"/
5.38"/ 85.9 mm .38"/
116.7 mm 9.7 mm
2.63"/
66.8 mm
4.69"/ .38"/
119.1 mm 9.7 mm

1.31"/
33.3 mm
Lighting: Explosionproof — Area — Incandescent

Pendant Ceiling Short Bracket


Size
(Watts) A B C A B C A B C
60-200 13.69/347.7 13.13/333.5 7.06/179.3 16.50/419.1 15.94/404.9 7.06/179.3 15.00/381.0 14.44/366.8 9.50/241.3
200-300 14.75/374.7 13.69/347.7 8.81/223.8 17.56/446.0 16.50/419.1 8.81/223.8 16.00/406.4 15.44/392.2 10.38/263.7
Lighting

1286 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Photometric data shown here is based on a 200-watt of fixtures with a guard, multiply by value shown with
type PS-25 lamp, and is representative of the perfor- each curve.
mance for A-51 incandescent fixtures (Groups A and
B). For candlepower values of fixtures with other lamps,
use the following multipliers: 150 W (PS-25) – 0.70; and
300 W (PS-25) – 1.6. To determine candlepower values

Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector)

% Ceiling Rcc 80 70 50 30 10 0

% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .711 .669 .630 .669 .631 .595 .590 .560 .533 .518 .495 .473 .452 .434 .417 .383
2 .602 .541 .488 .567 .511 .465 .499 .455 .416 .437 .402 .371 .380 .352 .327 .296

ROOM CAVITY RATIOS


3 .519 .449 .393 .488 .424 .374 .430 .379 .336 .375 .335 .300 .325 .292 .264 .236
4 .456 .384 .328 .430 .364 .312 .379 .325 .282 .332 .288 .252 .288 .252 .223 .197
5 .400 .328 .274 .378 .311 .260 .334 .278 .236 .293 .247 .211 .254 .217 .187 .164
6 .357 .285 .234 .336 .270 .221 .297 .242 .200 .261 .215 .180 .227 .188 .159 .138
7 .318 .248 .200 .300 .234 .190 .265 .209 .171 .233 .187 .153 .204 .165 .135 .116
7.13"/
181.1 mm 8 .287 .219 .172 .270 .208 .164 .240 .187 .149 .212 .167 .134 .104 .147 .119 .101
9 .260 .194 .150 .246 .185 .143 .218 .166 .130 .192 .148 .117 .168 .131 .103 .087
10 .236 .173 .132 .222 .166 .126 .199 .149 .114 .175 .133 .102 .154 .117 .090 .075

Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector)

% Ceiling Rcc 80 70 50 30 10 0

Lighting: Explosionproof — Area — Incandescent


% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .797 .763 .733 .779 .748 .721 .745 .720 .697 .715 .695 .676 .689 .671 .655 .640
2 .687 .633 .586 .673 .622 .581 .645 .603 .566 .620 .585 .553 .597 .567 .541 .524
ROOM CAVITY RATIOS

3 .594 .530 .478 .583 .522 .474 .560 .508 .464 .538 .494 .457 .519 .481 .448 .431
4 .527 .458 .404 .517 .452 .400 .497 .440 .395 .479 .430 .390 .462 .419 .384 .366
5 .466 .393 .340 .456 .388 .337 .440 .379 .335 .424 .371 .330 .410 .364 .326 .310
6 .414 .342 .292 .406 .339 .288 .391 .331 .286 .378 .324 .283 .367 .317 .280 .264
7 .369 .298 .252 .362 .294 .248 .350 .288 .245 .337 .284 .242 .328 .279 .240 .225
8 .333 .265 .217 .327 .262 .216 .316 .257 .215 .307 .252 .213 .297 .248 .211 .196
14.00"/
355.6 mm
9 .302 .235 .189 .297 .232 .189 .287 .229 .188 .278 .224 .186 .270 .221 .185 .170
10 .273 .209 .167 .268 .209 .167 .261 .204 .166 .253 .201 .163 .247 .198 .162 .149

Lighting

11.16"/
283.5 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1287


© September 2010
EDT Incandescent Luminaires
Dust-Ignitionproof
Suitable for use in Wet Locations.

Class II, Division 1 and 2, Groups E, F, G


Class III

Hub Size Catalog


Description Watts
(Inches) Number
Pendant Lighting Fixture ➊

9.00"/ One tapped opening for rigid or flexible mounting,


228.6 mm 60-200 W 1/2 EDTP2050
with heat-resistant clear globe

5.25"/
133.4 mm
Heat-Resistant Clear Glass Globe
4.28"/
108.7 mm

7.00"/
177.8 mm 60-200 W VSGL-2HR

5.25"/
133.4 mm

Globe Guard
4.28"/
Lighting: Explosionproof — Area — Incandescent

108.7 mm

7.00"/ 60-200 W DPGU-2


177.8 mm

5.25"/
133.4 mm

Replacement Porcelain Shock-Absorbing Socket — Medium Base

60-200 W VPLR-123
Lighting

➊ T3C maximum operating temperature. Supply wire 302 °F/150 °C. Maximum ambient temperature 77 °F/25 °C. Vertical mount only (globe down).

1288 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.

NEC: CEC: V
Class 1, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D
Marine Type Electric Fixtures Class II, Division 1, Groups E, F, G
Outside Type (Salt Water) Class II, Division 2, Groups F, G
Class III
CSA 4X

Applications
• UL Listed for Marine Type Electric Fixtures Outside Type (Salt
Water).
• Ideal in Class I, Division 1 and 2 installations in refineries, in
pipeline transportation facilities, at drilling rigs and in production
facilities on land and marine platforms.
• Class I, Division 1 areas include:
(1) enclosed derricks, mud tanks, desander-desilter, gas-
operated control devices, oil-gas separation vessels, shale
shakers and flowing or beam wells
(2) flowing or beam wells in open areas with cellar or below
grade sump
(3) on refinery docks where tankers are loaded with hoses or
loading arms
(4) in compressor buildings (open or enclosed) where methane
gas is present
• Virtually all enclosed areas at drilling operations or refineries
where ventilation is inadequate, or where a cellar or below grade
sump exists, are Class I, Division 1. Shown with Optional High Bay Reflector
Features
Effective Protected area: 1.8 Square Feet
• Choice of mountings: (1) crossarm with degree indicator; (2)
junction box for horizontal or vertical mount; and (3) swivel for
pole mount (screws onto standard 2” pipe threads). Options
• Fixtures operate safely in high ambient temperatures. For
• Fuses for field installation are ordered by catalog number from
example, in Class I areas the 150 W HPS unit operates at a
the fuse kit table
maximum fixture surface temperature of 248 °F/120 °C in a
• Quartz Auxiliary Emergency Lamp for PSMH and HPS fixtures.
149 °F/65 °C ambient (212 °F/100 °C temperature in a 104 °F/
Relay switch installed fixture. Add suffix -E to fixture catalog
40 °C ambient).
number.
• Arrangement of heat-producing components results in more
• “Smart Hot Restrike” Emergency Option available for 150 W
efficient heat dissipation for cooler fixture operation.
HPS. Add suffix -SR.
• All threaded joints are flame-tight.
• Hot Restrike Option available for 150 W HPS. Add suffix -R.
• Five threads are always fully engaged in an
• Smart Starter. Add suffix -S
explosionproof manner.
• Factory sealed. External seals not required. Certifications and Compliances
• Strategic location of lamp socket, in combination with the • UL Standard: UL 1598, UL 844
interior prism design of the glass globe, provides optimum light • UL Listed: E10444
distribution and control. • CSA Standard: C22.2 No. 250, C22.2 No. 137
• Heat- and impact-resistant globes have smooth • CSA Certified: 025428
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Ballasts operate at low temperatures – PSMH: -20 °F/-29 °C;

Lighting: Explosionproof — Floodlight


HPS: -40 °F/ -40 °C.
Standard Materials
• Ballast housing, guard and junction box, and pole mounts:
copperfree (4/10 of 1% max.) aluminum
• Crossarm mount: malleable iron
• Trunnion: steel.
• High bay reflector: aluminum
• Standard dome, deep dome and 30° angle reflectors:
fiberglass reinforced polyester
• Socket: porcelain
• Screw shell: nickel-plated phosphor bronze
Standard Finishes
• Ballast housing, guard, trunnion and mounting accessories:
epoxy-clad finish. Powder coat baked finish, electrostatically
applied for complete, uniform corrosion protection

V CSA Certification only.


Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1289


© September 2010
Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.

NEC: CEC: V
Class 1, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D
Marine Type Electric Fixtures Class II, Division 1, Groups E, F, G
Outside Type (Salt Water) Class II, Division 2, Groups F, G
Class III
CSA 4X

Classified Area Suitability — Suitability includes use of reflector


Class II, Division 1 & 2
Class I, Division 1 & 2 With Globe or with With Globe or with Globe & Reflector
Globe & Reflector UL/NEC/CEC Temp. Ident. No. CEC Temp. Ident. No.
Lamp Lamp Supply Wire Ambient Temp Nameplate NEC CEC V Nameplate CEC V
Type Watts (°F/˚°C) (°F/°˚C) Marking Groups Groups Marking Groups
150 122/60 104/40 T5 C,D B, C, D T3A E,F
150 167/75 131/55 — C,D B, C, D T3 —
High Pressure
250 167/75 104/40 T4 C,D B, C, D — —
Sodium
250 167/75 131/55 — C,D B, C, D — —
400 185/85 104/40 T3A C,D B, C, D — —
175 167/75 104/40 T3B C,D B, C, D T3C E,F,G
250 167/75 104/40 T3B C,D B, C, D T3A E,F
Pulse Start
320 167/75 104/40 T3 C,D B, C, D — —
Metal Halide
350 167/75 104/40 T3 C,D B, C, D — —
400 167/75 104/40 T3 C,D B, C, D — —
175 167/75 104/40 T4 — B, C, D T3C E, F, G
Metal Halide V 250 167/75 104/40 T4 — B, C, D T3A E, F
400 167/75 104/40 T3C — B, C, D — —
Lighting: Explosionproof — Floodlight

V CSA Certification only.


Lighting

1290 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH. Mogul Base.

NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)

Lamp ANSI Lamp Type Catalog Number ➊➌


Watts HPS PSMH HPS PSMH
Fixture Unit
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
150 S55 M102 CFL150MT CFP150MT
175 — M137/M152 — CFP175MT
250 S50 M138/M153 CFL250MT CFP250MT
320 — M145 — CFP320MT
350 — M131 — CFP350MT
400 S51 M135/M155 CFL400MT CFP400MT
Fixture Unit with Junction Box for Horizontal or Vertical Mounting ➋
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30” Flexible Coupling connects to 3/4” fixture hub
and to 1/2” junction box opening. Furnished with one 3/4” Close-up Plug. Has Locking Screw for horizontal
adjustment.
150 S55 M102 CFL150JBMT CFP150JBMT
175 — M137/M152 — CFP175JBMT
250 S50 M138/M153 CFL250JBMT CFP250JBMT
320 — M145 — CFP320JBMT
350 — M131 — CFP350JBMT
400 S51 M135/M155 CFL400JBMT CFP400JBMT
Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) ➋
2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal adjustment. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
150 S55 M102 CFL150SFMT CFP150SFMT
175 — M137/M152 — CFP175SFMT
250 S50 M138/M153 CFL250SFMT CFP250SFMT
320 — M145 — CFP320SFMT
350 — M131 — CFP350SFMT
400 S51 M135/M155 CFL400SFMT CFP400SFMT
Fixture Unit with Crossarm Mounting ➋

Lighting: Explosionproof — Floodlight


For mounting to flat surface. 180° horizontal adjustment with degree indicator. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to any 1/2” opening (1/2 – 14 NPT).
150 S55 M102 CFL150CAMT CFP150CAMT
175 — M137/M152 — CFP175CAMT
250 S50 M138/M153 CFL250CAMT CFP250CAMT
320 — M145 — CFP320CAMT
350 — M131 — CFP350CAMT
400 S51 M135/M155 CFL400CAMT CFP400CAMT

➊ To order fixture with guard, add suffix -G before voltage suffix.


➋ Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
Lighting

➌ Change suffix -MT (120/208/240/277 V) to -480 for 480 V.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1291


© September 2010
Code•Master 2™ HID Factory Sealed Floodlights V
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X

Lamp ANSI Lamp Type Catalog Number ➊➌


Watts HPS PSMH MH HPS PSMH MH
Fixture Unit
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
150 S55 M102 — CFL150TTCN CFP150TTCN —
175 — M137/M152 M57/H39 — CFP175TTCN CFH175TTCN
250 S50 M138/M153 M58/H37 CFL250TTCN CFP250TTCN CFH250TTCN
320 — M145 — — CFP320TTCN —
350 — M131 — — CFP350TTCN —
400 S51 M135/M155 M59/H33 CFL400TTCN CFP400TTCN CFH400TTCN
Fixture Unit with Junction Box for Horizontal or Vertical Mounting ➋
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30” Flexible Coupling connects to 3/4” fixture hub
and to 1/2” junction box opening. Furnished with one 3/4” Close-up Plug. Has Locking Screw for horizontal
adjustment.
150 S55 M102 — CFL150JBTTCN CFP150JBTTCN —
175 — M137/M152 M57/H39 — CFP175JBTTCN CFH175JBTTCN
250 S50 M138/M153 M58/H37 CFL250JBTTCN CFP250JBTTCN CFH250JBTTCN
320 — M145 — — CFP320JBTTCN —
350 — M131 — — CFP350JBTTCN —
400 S51 M135/M155 M59/H33 CFL400JBTTCN CFP400JBTTCN CFH400JBTTCN
Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) ➋
2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal adjustment. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
150 S55 M102 — CFL150SFTTCN CFP150SFTTCN —
175 — M137/M152 M57/H39 — CFP175SFTTCN CFH175SFTTCN
250 S50 M138/M153 M58/H37 CFL250SFTTCN CFP250SFTTCN CFH250SFTTCN
320 — M145 — — CFP320SFTTCN —
350 — M131 — — CFP350SFTTCN —
400 S51 M135/M155 M59/H33 CFL400SFTTCN CFP400SFTTCN CFH400SFTTCN
Fixture Unit with Crossarm Mounting ➋
Lighting: Explosionproof — Floodlight

For mounting to flat surface. 180° horizontal adjustment with degree indicator. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to any 1/2” opening (1/2 – 14 NPT).
150 S55 M102 — CFL150CATTCN CFP150CATTCN —
175 — M137/M152 M57/H39 — CFP175CATTCN CFH175CATTCN
250 S50 M138/M153 M58/H37 CFL250CATTCN CFP250CATTCN CFH250CATTCN
320 — M145 — — CFP320CATTCN —
350 — M131 — — CFP350CATTCN —
400 S51 M135/M155 M59/H33 CFL400CATTCN CFP400CATTCN CFH400CATTCN

➊ To order fixture with guard, add suffix -G before voltage suffix.


➋ Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
➌ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
Lighting

V CSA Certification only.

1292 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Floodlight Accessories
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.

Description Catalog Number


Junction Box for Horizontal or Vertical Mounting
Box has 1/2” opening for threading to Flexible Coupling, and two 3/4” AF-JB
conduit openings (3/4 – 14NPT) and is furnished with one 3/4” close-up
plug. Locking screw for horizontal adjustment. Trunnion bolts furnished.
Aluminum, gray epoxy finish.

Pole-Top Mount (on 2” Threaded Pipe)


Threads onto 2” pipe with tapered threads (2-11 – 1/2 NPT). Includes AF-SF
floodlight trunnion bolts. Locking screw for horizontal floodlight
adjustment. Aluminum, gray epoxy finish.

Crossarm Mounting Bracket


Has 180° horizontal adjustment – degree-marked. Facilitates mounting G-AM-8-CA
floodlight to crossarm or other flat surface, or to G-AM-8-WB Pole/Wall
Mounting Bracket (see photo below). Includes floodlight trunnion bolts.
Malleable iron, plated, chromate sealed, architectural bronze EPOXY finish.
Polyester Reflectors – 150 W through 400 W
Standard Dome CMR-4ST
Deep Dome CMR-4DD
30° Angle CMR-4AN

Aluminum High Bay Reflectors – 150 W through 400 W


CMR-4HB

Flexible Coupling – 30” Long


Connects to 3/4” Fixture Unit hub (3/4 – 14 NPT) and to 1/2” AF-EXL
Junction Box or Pole-Top Accessory opening (1/2 – 14 NPT).

Quartz Emergency Lamp for Pulse Start Metal Halide and High Pressure Sodium Fixtures
Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp.
This D.C. bayonet base socket is in addition to the standard lamp socket, independent of the lighting fixture voltage.
-E
HPS Smart Hot Restrike

Lighting: Explosionproof — Floodlight


Smart Hot Restrike will immediately restrike an HPS lamp when power is restored after a momentary power interruption.
The smart function removes the hot restrike ignitor from the circuit if the lamp burns out or is removed from the socket.
Eliminates starter failures caused by prolonged operation with cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs.
Optional for 150 W fixtures (HPS only) Add Suffix -SR
HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for 150 W fixtures (HPS only) Add Suffix -R
HPS Smart Starter
Smart Starter for HPS and PSMH fixtures. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally
start lamp. Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by
prolonged operation with cycling or failing lamps and simplifies finding their location, reducing maintenance and repair costs.
Optional for all fixture watts Add Suffix -S
G-AM-8-CA Crossarm Mounting Bracket
Shown with G-AM-8-WB Pipe/Wall Mounting Bracket.
The G-AM-8-WB bracket is not furnished with fixtures.
Lighting

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1293


© September 2010
Code•Master 2™ HID Factory Sealed Floodlight Ballast and Fuse Data
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.

NEC: CEC: V
Class 1, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D
Marine Type Electric Fixtures Class II, Division 1, Groups E, F, G
Outside Type (Salt Water) Class II, Division 2, Groups F, G
Class III
CSA 4X

Ballast Amps Fuse Kit Catalog Number


High Pressure Pulse Start Metal Halide Metal Halide Fuse
Lamp Sodium ➊ Super CWA CWA Quantity
Watts Volts Start Operating Start Operating Start Operating Required HPS PSMH MH
120 2.00 1.66 — — — — 1 CF-10 — —
208 1.16 0.96 — — — — 2 CF-5 — —
150 240 1.00 0.83 — — — — 2 CF-5 — —
277 0.88 0.75 — — — — 1 CF-5 — —
347 0.52 0.56 — — — — 1 CF-5 — —
480 0.50 0.44 — — — — 2 CF-3 — —
120 — — 1.10 1.86 1.30 1.80 1 — CF-5 CF-5
208 — — 0.75 1.23 0.75 1.10 2 — CF-3 CF-3
175 240 — — 0.65 0.98 0.65 0.90 2 — CF-3 CF-3
277 — — 0.55 0.87 0.55 0.80 1 — CF-2 CF-2
347 — — 0.25 0.65 0.50 0.65 1 — CF-2 CF-2
480 — — 0.25 0.50 — — 2 — CF-2 —
120 1.75 2.70 1.96 2.50 1.20 2.60 1 CF-8 CF-8 CF-8
208 1.00 1.50 1.13 1.45 0.65 1.50 2 CF-5 CF-5 CF-5
240 0.85 1.30 0.98 1.25 0.60 1.30 2 CF-5 CF-5 CF-5
250
277 0.75 1.15 0.85 1.10 0.50 1.12 1 CF-5 CF-3 CF-3
347 0.60 0.93 0.62 0.90 0.80 0.90 1 CF-5 CF-3 CF-3
480 0.40 0.65 0.32 0.67 — — 2 CF-2 CF-2 —
120 — — 3.30 3.25 — — 1 — CF-8 —
208 — — 1.90 1.90 — — 2 — CF-6 —
240 — — 1.60 1.65 — — 2 — CF-5 —
320
277 — — 1.40 1.40 — — 1 — CF-5 —
347 — — 0.70 1.10 — — 1 — CF-5 —
480 — — 0.45 0.85 — — 2 — CF-3 —
120 — — 3.60 3.70 — — 1 — CF-10 —
208 — — 2.10 2.10 — — 2 — CF-8 —
240 — — 1.80 1.80 — — 2 — CF-5 —
350
277 — — 1.60 1.60 — — 1 — CF-5 —
347 — — 0.70 1.01 — — 1 — CF-5 —
480 — — 0.60 0.90 — — 2 — CF-3 —
120 3.10 3.90 3.50 4.00 3.25 4.00 1 CF-15 CF-10 CF-10
208 1.80 2.25 2.00 2.30 1.90 2.30 2 CF-8 CF-8 CF-8
240 1.60 1.95 1.75 2.00 1.65 2.00 2 CF-5 CF-5 CF-5
400
277 1.35 1.70 1.50 1.75 1.40 1.75 1 CF-5 CF-5 CF-5
347 1.00 1.32 1.10 1.35 1.20 1.40 1 CF-5 CF-5 CF-5
480 0.80 1.00 0.75 1.00 — — 2 CF-5 CF-3 —
Lighting: Explosionproof — Floodlight

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V,
and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp
➊ 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts.
Lighting

V CSA Certification only.

1294 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ HID Factory Sealed Floodlight Dimensions
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.

Dimensions in Inches/Millimeters

2.95"/ 3.25"/
74.9 mm 2.38"/ 82.6 mm
60.5 mm

4.75"/
120.7 mm
4.75"/ 5.70"/
120.7 mm 144.8 mm
5.00"/
5.65"/ 127 mm Dia.
143.5 mm

4.94"/
2.38"/ 125.5 mm
60.5 mm

16.44"/
417.6 mm
36.44"/
925.6 mm

15.94"/
404.9 mm

11.50"/
292.1 mm

127 mm
5.00"/
88.9mm
3.50"/
1.75"/
44.5 mm
/
80" 1.50"/
20..3 mm 38.1 mm
528
4.44"/
112.8 mm

0"/
13.0 mm
330.2

/
.6" m
23 .4 m
9 /
59 0.6"mm
2 .2
3
52

Lighting: Explosionproof — Floodlight


292.1 mm

5.00"/
508 20"/
11.5"/

127 mm Dia.
mm
R 2.95"/
30
12 .8 m
4

74.9 mm
.0" m

11.50"/
/

292.1 mm
18.63"/
473.2 mm
7.13"/
181.1 mm

53.0"/1346.2 mm Min.
1.75"/
44.5 mm
2.94"/ 3.50"/
74.7 mm Dia. 88.9 mm
2.00"/ 13.0"/
50.8 mm 330.2 mm

Weights
150 W 175 W 250 W 320 W 350 W 400 W
46 lb/21 kg 46 lb/21 kg 70 lb/32 kg 70 lb/32 kg 70 lb/32 kg 70 lb/32 kg

V CSA Certification only.


Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1295


© September 2010
Code•Master 2™ HID Factory Sealed Floodlight Photometric Data
Marine (Outside Type). Explosionproof
Typical Footcandle Values for Iso-Footcandle Curves. Data Based on 400 W HPS (50,000 Lumens) Clear Mogul Base Lamps.

400 W HPS Floodlight at 45° Angle with High Bay Reflector * 400W MH Floodlight at 45° Angle with High Bay Reflector

Distance in terms of mounting height

Mounting FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES Mounting FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES
Height Height
(feet) A B C D E F G H I (feet) A B C D E F G H I
Lighting: Explosionproof — Floodlight

15 52.52 43.34 31.00 17.05 10.23 4.77 2.43 1.36 0.84 15 33.97 22.10 16.12 9.69 6.40 4.12 2.13 1.13 .67

20 29.54 24.38 17.44 9.59 5.75 2.68 1.37 0.77 0.47 20 19.11 12.43 9.07 5.45 3.60 2.31 1.20 .64 .38

25 18.91 15.60 11.16 6.14 3.68 1.72 0.87 0.49 0.30 25 12.23 7.96 5.80 3.49 2.30 1.48 .77 .41 .24

30 13.13 10.84 7.75 4.26 2.56 1.19 0.61 0.34 0.31 30 8.49 5.52 4.03 2.42 1.60 1.03 .53 .28 .17

35 9.65 7.96 5.69 3.13 1.88 0.88 0.45 0.25 0.15 35 6.24 4.06 2.96 1.78 1.18 .76 .39 .21 .12

40 7.39 6.10 4.36 2.40 1.44 0.67 0.34 0.19 0.12 40 4.78 3.11 2.27 1.36 .90 .58 .30 .16 .10

45° 45°

MH MH

1.0MH 1.0MH
Lighting

* For 250 Watt HPS Clear, 30,000 Lumen lamp, multiply all FTC values by 0.60

1296 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
EFL Series HID and Quartz Floodlights V
cCSAus. Explosionproof

Class I, Zone 1 & 2


Ex de IIB T1/T2/T3
Class I, Zone 1 & 2,
AEx de IIB T1/T2/T3
IP66 / 67

Applications
• Designed for large area lighting in industrial outdoor and indoor
explosionproof areas.
• Ideal for use in Zone 1 and 2 applications in the oil and gas
industry in such areas as refineries, pipelines and offshore
drilling rigs.
Features
• Fast and easy tubular lamp replacement via threaded entry at
the end of the fixture. Suitable for HPS and HPI-T MH lamps
only. Other lamps require lens cover removal for servicing.
• Lamp holder can be easily field adjusted for either a narrow or
wide beam type.
• Thermally separated ballast provides for extended life.
• Easy, efficient wiring process due to a separate Ex-e terminal
chamber. Options
• Choice of mounting with a galvanized yoke bracket, fixed • Overhead diffuser. Black painted, galvanized steel. Suffix –D.
horizontal brackets, two different sizes of tube/pole mount • Protective wire guard. Zinc plated steel. Suffix –G.
brackets or without brackets for custom installation. • Hot Restrike Igniter. Ignites a hot lamp shortly after a power dip
• Tempered safety glass lens is factory sealed into the cover or outage extinguishes the lamp. Suffix –R.
frame. • Safety Starter. Shuts off device in the event of a lamp failure.
• Suitable for use in up to 131 °F/55 °C ambient temperatures. Suffix –S.
• 2 – M20 threaded cable entries for ease of wiring. Supplied c/w • Additional wiring terminals. For 3 Phase loop in/out. Suffix –T.
one close-up plug and one Ex-e non-armored cable gland.
• One external 4mm2 and one 6mm2 earth/ground terminals. Certifications and Compliances
• Universal mounting for vertical or horizontal positioning. • cCSAus: LR25428
• Reversible hinge allows for fixture access from either side.
• Mogul Base Lamp is supplied as standard. Optional export
version would be supplied with E40 export socket.
• Highly polished internal Aluminium reflector.
Standard Materials
• Housing and door: copperfree marine grade aluminum alloy
• Lens: tempered safety glass
• Reflector: highly polished aluminium
• Closure bolts: 316 stainless steel
Standard Finishes
• Exterior finish: Housing and door: gray polyester epoxy.

Lighting: Explosionproof — Floodlight


Catalog Numbering Guide
EFL H 40 B TT L

EFL Series: Wattage: HID Ballast Type & Voltage


Explosionproof 10 - 1000W Quartz Halogen TT - CWA for 120/277/347V
Floodlights 15 - 150W HPS/MH MT - CWA for 120/208/240/277V
17 - 175W MH/PSMH XP - CWA for 120/220-240V 50 Hz
20 - 200W PSMH C5 - CWI for 480V
25 - 250W HPS/MH C6 - CWI for 600V
40 - 400W HPS/MH A1 - No Ballast - Quartz Only
50 - 500W Quartz Halogen
Lamp Type: Mounting: Accessory Options:
H - Metal Halide/ Mercury Vapor B - Galvanized Yoke Bracket (Std. Offering) D - Overhead Diffuser
L - High Pressure Sodium H - Set of Horizontal Fittings G - Protective Wire Guard
P - Pulse Start Metal Halide C1 - Clamp Bracket. For 1-1/4” – 1-1/2” Tube L - Lamp Included (HIDOnly)
Q - Halogen C2 - Clamp Bracket. For 2” Tube R - Protected Hot R Strike
N - No Mounting Hardware Supplied S - Safety Starter (not required
with R)
Lighting

V cCSAus Certification.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1297


© September 2010
EFL Series HID and Quartz Floodlights V
cCSAus. Explosionproof

Class I, Zone 1 & 2


Ex de IIB T1/T2/T3
Class I, Zone 1 & 2,
AEx de IIB T1/T2/T3
IP66 / 67

T Code T Code
Fixture Ordering Fixture Catalog
Supplied Std. w/ Yoke Mtg. 104 °F/40 °C 131 °F/55 °C Input Voltages Wt. Vol. Number
Metal Halide/Mercury Vapor
150 W T3 T3 120/277/347 V 60Hz 60 3 EFLH15B-TTCN *
250 W T3 T3 120/277/347 V 60Hz 62 3 EFLH25B-TTCN
400 W T3 T3 120/277/347 V 60Hz 66 3 EFLH40B-TTCN
Pulse Start Metal Halide
175 W T3 T3 120/277/347 V 60Hz 62 3 EFLP17B-TTCN *
200 W T3 T3 120/277/347 V 60Hz 62 3 EFLP20B-TTCN *
250 W T3 T3 120/277/347 V 60Hz 25 3 EFLP25B-TTCN *
400 W T3 T3 120/277/347 V 60Hz 66 3 EFLP40B-TTCN *
High Pressure Sodium
150 W T3 T3 120/277/347 V 60Hz 60 3 EFLL15B-TTCN
250 W T3 T3 120/277/347 V 60Hz 62 3 EFLL25B-TTCN
400 W T3 T3 120/277/347 V 60Hz 66 3 EFLL40B-TTCN
Tubular Quartz Halogen
500 W T1 T1 Lamp sockets rated 71 3 EFLQ50B-A1CN
125-250 Vac
1000 W T1 T1 71 3 EFLQ10B-A1CN

Voltages — Add Suffix Below to Catalog Number


Volts 120 208 220 240 277 347 480 600
CWA -MT -MT - -MT -MT - -A6 ‡
-
CWI -C1 -C2 - -C3 - -C5 -C6 -C7
50 Hz CWA -XP - -XP -XP - - -

Accessories and Replacement Parts

Size
In/mm Catalog Number Catalog Number
Lighting: Explosionproof — Floodlight

Galvanized Steel Hinged Bracket Clip on Diffuser

PNTB1 PND1

Pole Mounting Brackets Protective Guard


1-1/4” to 1-1/2”/
PNPB115
31.8 mm to 38.1 mm PNG1

2”/50.8 mm PNPB120
Horizontal Fixed Mounting Bracket

PNHB1

* Depending on availability of tubular type lamps, may require removal of lens cover for servicing.
‡ Supplied as export voltage only. Not suitable for CEC applications
V cCSAus Certification.
Lighting

1298 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
EFL Series HID and Quartz Floodlight Dimensions and Photometric Data V
cCSAus. Explosionproof

Dimensions in Inches/Millimeters

28.54”/724.9 mm

13.45”/341.6 mm

16.77”/426.0 mm

158.8 mm
6.25”/
Photometric Data

Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal


Luminaire symbol according to NF C 71-121 Transverse

250W halide Narrow Beam 250W halide Wide Beam 400W halide Narrow Beam 400W halide Wide Beam
Efficiency 68.3% Efficiency 67.9% Efficiency 49.3% Efficiency 46.7%
NF C 71-121: 0,68B NF C 71-121: 0,68C NF C 71-121: 0,49C NF C 71-121: 0,46C
Candela Candela Candela Candela
Distribution Distribution Distribution Distribution
0-180 90-270 0-180 90-270 0-180 90-270 0-180 90-270
0 505 505 0 301 301 0 217 217 0 105 105
5 515 499 150° 120° 5 303 318 150° 120° 5 210 219 150° 120° 5 104 106 150° 120°
105° 105° 105° 105°
10 512 469 10 299 342 10 218 231 10 108 130
15 501 403 90° 15 294 387 90° 15 223 205 90° 15 124 165 90°
75° 75° 75° 75°

Lighting: Explosionproof — Floodlight


20 476 312 20 287 382 20 238 193 20 148 177
25 453 248 60° 25 286 306 60° 25 255 148 60° 25 167 183 60°
30 427 190 30 271 237 30 266 132 30 165 147
35 394 146 45° 35 231 208 45° 35 263 130 45° 35 142 127 45°
40 368 117 40 172 186 40 244 116 40 116 113
45 290 97 45 133 140 45 201 104 45 74 115
50 160 12 30° 50 83 104 30° 50 136 37 30° 50 52 103 30°
55 51 7 55 48 18 55 85 15 55 48 40
60 34 4 0° 15° 60 34 8 0° 15° 60 51 8 0° 15° 60 44 13 0° 15°
65 15 4 65 23 6 65 28 6 65 34 9
70 6 4 70 6 6 70 5 4 70 18 6

* 400 W MH: Efficiency rate lower than 250 W due to thermal deflector between glass and lamp, requested for T3.
V cCSAus Certification.
Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1299


© September 2010
PB, PC & PL Series
Floodlights – Flameproof

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Applications
• Designed for large area lighting in industrial outdoor and indoor
hazardous areas. Type PB
• Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas
industrysuch as: refineries, pipelines, warehouses, offshore
platforms and drilling rigs.
Features
• Gray epoxy painted light marine grade aluminum housing
and door.
• Fast and easy lamp replacement via threaded cover on the
side of the fixture (Types PB and PC). The cover is fitted with
a short safety chain. Type PC
• Lampholder can be easily field-adjustable for either a narrow
or wide beam.
• Fixtures operate safely in high ambient temperatures up
to +131°F/55°C and in low ambient temperature up to -40 °F/-
40 ºC (-13 °F/-25 ºC for PC type and -40 °F/-40 ºC for PL type). • Screwed-on overhead diffuser out of galvanized steel with
• Electrical components (ballast, ignitor and capacitor) are black painting (see accessories).
thermally separated from the lighting compartment with a • Screwed-on zinc-coated protection guard for Types PB and PC
bulkhead (Type PB) or with an insulating protection (see accessories).
(Types PC and PL), providing extended life. • 1000 W HP Sodium (Type PL) with separate Ex d housing
• Easy and efficient wiring due to separate Ex e terminal box for ballast.
with wiring onto 2 captive terminals 2 x .009 in²/6 mm2; 2
internal earth terminals capacity .009 in2/6 mm2 and 1 external Certifications and Compliances
earth terminal capacity .006" in²/4 mm2. • Certification Type: PJd
• 2 x .79"/20 mm clearance holes throughwire cable entries • Zone 1 - 2
supplied with: — Conforming to ATEX 94/9/CE: CE 0081 II 2 G
— One Ex e unarmored cable gland — ATEX/IEC Protection: Ex de IIB (Type PB et PL)
(sealing dia. .26" to .57"/6.5" to 14.5 mm) Ex de IIC (Type PC)
— One blanking plug — T Rating: See Tables
— Two M20 locknuts. • Zone 21 - 22
• For use with either tubular or ellipsoidal shape lamps. — Conforming to ATEX 94/9/CE: CE 0081 II 2 D
See ordering information for details. — ATEX/IEC Protection: Ex tD A21
• Choice of mounting with galvanized hinged bracket fixed — Surface Temperature: See tables
mounting or tube/pole mounting with galvanized brackets. • Ambient Temperature: -4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C (Type
• Toughened glass factory-sealed into the floodlight body PB and PC) (-13 °F/-25 °C for PC Type as an option) -40 °F/-40
(Types PC and PL) or factory-sealed into the cover frame °C ≤ Ta ≤ +131 °F/55 °C (Type PL)
(Type PL). • CE Declaration of Conformity: 50207
• Operates in any position (except Type PL, to be used only • ATEX Certificate: LCIE 99/ ATEX 6002
for wall-mounting or down lighting applications). • IECEx Certificate: IECEx LCI 04.0020
• Reversible hinge allows for fixture access from either side. • Other Certifications: GOST
Lighting: Explosionproof — Floodlight

• E40 or H3 lampholders for the 2 x 70 W Vac/Vdc • Index of Protection (solid & liquid): IP66 (Type PB)
halogen version. IP66/67 (Types PC and PL)
• Internal symmetric reflector. • Impact Resistance (shock): IK10
• Ex Standards EN / IEC 60079-0; 60079-1; 60079-7;
Standard Materials 61241-0; 61241-1
• Housing and door: copperfree marine-grade aluminum • Product Standards: EN / IEC 60598-1
alloy • EMC Standards: EN / IEC 55015; 61547
• Lens: toughened safety glass • Other Standards: EN / IEC 60529 (IP); 62262 (IK)
• Reflector: bright highly polished aluminum
• Bolts: stainless steel bolt North American CEC/NEC Certification:
• Cable gland and blanking plug: polyamide • AEx/Ex de IIB IP 66 (Type PB only) cCSAus Ex de IIB IP 66
• Locknut: nickel plated brass (Type PB only).
• 175 W Metal Halide and Pulse Start Metal Halide.
Standard Finishes • Safety starter.
• Housing and door: gray epoxy powder paint
Options:
• Other voltages, please contact your sales representative.
• Terminal block with 2 more terminals for wiring with 3 phases
plus Neutral in 380/415 V (loop in/loop out wiring possible): add
suffix -T at the end of the catalog number.
Lighting

1300 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
PB, PC & PL Series
Floodlights – Flameproof

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
PB A H 15 XJ B

Series: Lamp Type: Voltage:


PB - IIB H - Metal Halide XJ - 230/240 Vac 50 Hz (Magnetic Ballast)
PC - IIC L - Sodium XC - 230 Vac 50 Hz (Magnetic Ballast) ➋
PL - IIB Low Temperature M - Mercury Vapor XA - 220 Vac 50 Hz (Magnetic Ballast) ➋
Rating ➍ Z - Halogen BT - 24 Vac/Vdc ➊
Zone 1, 2, 21 and 22 Lamp Power: Options:
ATEX/IEC Certified 70 - 2 x 70 W Halogen ➊ B - Hinged Bracket
15 - 150 W Included
25 - 250 W T - Extra
40 - 400 W Terminals ➌
50 - 500 or 1000 W Halogen C - -25°C Ambient
60 - 600 W ➎ Temperature ➐
1K - 1000 W ➏

Temperature Rating Chart: Types PB - PC


Gas Temperature Rating According to Ta Dust
Lamp Wattage +104°F/40°C +122°F/50°C +131°F/55°C Surface Temperature °F/°C
2 x 70 W - H3 ➊ T4 T4 T4 266/130
150 W Sodium T4 T3 T3 293/145
250 W Sodium T3 T3 T3 383/195
250 W Metal Halide T3 T3 T3 387/197
250 W Mercury Vapor T3 T3 T3 381/194
400 W Sodium T3 T3 T3 372/189
400 W Metal Halide T3 T3 T3 379/193
400 W Mercury Vapor T3 T3 T3 383/195
600 W Sodium T2 T2 T2 495/257
500 W Halogen T2 T2 T2 513/267
1000 W Halogen T1 T1 T1 712/378

Temperature Rating Chart: Types PL

Lighting: Explosionproof — Floodlight


Gas Temperature Rating According to Ta Dust
Lamp Wattage +104°F/40°C +122°F/50°C +131°F/55°C Surface Temperature °F/°C
150 W Sodium T4 T3 T3 293/145
250 W Sodium T4 T3 T3 293/145
250 W Metal Halide T3 T3 T3 387/197
250 W Mercury Vapor T3 T3 T3 381/194
400 W Sodium T4 T3 T3 291/144
400 W Metal Halide T3 T3 T3 379/193
400 W Mercury Vapor T3 T3 T3 383/195
600 W Sodium T2 T2 T2 495/257
500 W Halogen T2 T2 T2 513/267
1000 W Halogen T1 T1 T1 712/378

➊ Only for IIB Version - 2 x 70 W Halogen 24 Vac/Vdc.


➋ Only for IIB Low Temperature Rating Version Type PL.
➌ 3 Phase + Neutral.
➍ Only for 250 W and 400 W Versions.
➎ Only Sodium for PC Series (IIC).
➏ Only Sodium for PL Series + Seperate Gear Box.
Lighting

➐ Only IIC Version.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1301


© September 2010
PB, PC & PL Series
Floodlights – Flameproof

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Lamp Voltage Lamp Type Weight Volume Catalog


Wattages Lampholder (+/-10%) Ellipsoidal Tubular lbs/kgs in³/dm³ Number
Ex de IIB Floodlight - PB Series
High Pressure Sodium
150 W E40 230/240 V 50 Hz x x 65/29.3 4847/79.4 PBAL15XJB
250 W E40 230/240 V 50 Hz x x 67/30.3 4847/79.4 PBAL25XJB
400 W E40 230/240 V 50 Hz – x 70/31.8 4847/79.4 PBAL40XJB
Mercury Vapor
250 W E40 230/240 V 50 Hz x x 65/29.3 4847/79.4 PBAM25XJB
400 W E40 230/240 V 50 Hz – x 66/29.8 484779.4 PBAM40XJB
Metal Halide
250 W E40 230/240 V 50 Hz x x 67/30.3 4847/79.4 PBAH25XJB
400 W E40 230/240 V 50 Hz – x 70/31.8 4847/79.4 PBAH40XJB
Halogen
500/1000 W E40 – x 58/26.3 4847/79.4 PBAZ50B
2 x 70 W H3 24 Vac/Vdc 50 Hz – – 60/27.3 4847/79.4 PBAZ70BTB *

Ex de IIC Floodlight - PC Series


High Pressure Sodium
150 W E40 230/240 V 50 Hz x x 64/29.0 6374/104.4 PCAL15XJB
250 W E40 230/240 V 50 Hz x x 66/30.0 6374/104.4 PCAL25XJB
400 W E40 230/240 V 50 Hz – x 71/32.0 6374/104.4 PCAL40XJB
600 W E40 230/240 V 50 Hz – x 77/35.0 6374/104.4 PCAL60XJB
Mercury Vapor
250 W E40 230/240 V 50 Hz x x 66/30.0 6374/104.4 PCAM25XJB
400 W E40 230/240 V 50 Hz – x 67/30.5 6374/104.4 PCAM40XJB
Metal Halide
250 W E40 230/240 V 50 Hz x x 66/30.0 6374/104.4 PCAH25XJB
Lighting: Explosionproof — Floodlight

400 W E40 230/240 V 50 Hz – x 71/32.0 6374/104.4 PCAH40XJB


Halogen
500/1000 W E40 – x 60/27.0 6374/104.4 PCAZ50B

Ex de IIB Floodlight - PL Series


High Pressure Sodium
250 W E40 230/240 V 50 Hz x x 83/37.5 6374/104.4 PLAL25XJB
400 W E40 220 V 50 Hz x x 83/37.5 6374/104.4 PLAL40XAB
Halogen
500/1000 W E40 – x 75/34.0 6374/104.4 PLAZ50B

Note : Floodlights supplied with hinged mounting bracket, 1 plug, 1 M20 cable gland (dia. 0.26” to 0.57”/6.5 to 14.5 mm). Lamps are not included.
Lighting

* Supplied with 2 x 70 W H3 bulbs, 24 Vac/Vdc

1302 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
PB, PC & PL Series Accessories and Spare Parts
Floodlights – Flameproof

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Type Catalog Number


Galvanized Steel Hinged Brackets
Type PB PBHBG
Type PL PLHBG
Type PC PCHBG
Pole/Tube Mounting Galvanized Steel Brackets
Type PB/PL 1-1/4" to 1-1/2" PNHC49G
2" PNHC60G

Type PC 1-1/4" to 1-1/2" PCHC49G


2" PCHC60G

Flat Surface Mounting Galvanized Steel Brackets


Type PB/PL PNSBG
Type PC PCSBG

400 W Mercury Vapor Lamp


Tubular LM400E40
Screwed-on Overhead Diffuser
Type PB PBGDG
Type PC PCGDG

Screwed-on Protective Guard


Type PB PBPGZ
Type PC PCPGZ

Lighting: Explosionproof — Floodlight


Visor (secured with 2 screws)
Type PC only PCVG

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1303


© September 2010
PB, PC & PL Series Dimensions
Floodlights – Flameproof

Type PB Type PC
Hinged Bracket Mounting Hinged Bracket Mounting
16.40"/
416.5 mm
5.91"/ 5.91"/
150 mm 150 mm

265 mm
10.43"/
29.53"/ 8.58"/
750 mm 218 mm
Flat Surface Mounting

13.43"/
426 mm

14.763"/
16.77"/

341 mm
375 mm
158 mm
6.22"/

1.97"/
50 mm
11.81"/
300 mm

Flat Surface Mounting Pole Mounting

25.75"/
654 mm

13.66"/
347 mm

Pole Mounting

Type PL
Hinged Bracket Mounting Flat Surface Mounting
Lighting: Explosionproof — Floodlight

1.97"/
50 mm 9.84"/
250 mm

4 x Ø0.49"/
12.5 mm
13.92"/353.5 mm

Quick access to
14.90"/378.5 mm

component with
threaded cover Quick access to
lamp

15.95"/396 mm
23.11"/587 mm 15.55"/395 mm

Pole Mounting
Lighting

1304 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
PB, PC & PL Series Photometric Data
Floodlights – Flameproof

Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal


Transverse
Luminaire symbol according to NF C 71-121
Narrow beam Metal Halide 250 W Narrow beam Metal Halide 400 W Narrow beam Halogen 1000 W
Efficiency 68.3% Efficiency 49.3% Efficiency 59.2%
NF C 71-121: 0.68B NF C 71-121: 0.49C NF C 71-121: 0.59B
Candela Distribution Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270 0-180 90-270
0 505 505 0 217 217 0 417 417
150° 120° 150° 120° 150° 120°
5 515
Degrees
499 105° 5 210
Degrees
219 105° 5 406
Degrees
418 105°
10 512 469 90° 10 218 231 90° 10 419 399 90°
15 501 403 15 223 205 15 419 330
75° 75° 75°
20 476 312 20 238 193 20 408 266
25 453 248 60° 25 255 148 60° 25 398 218 60°
30 427 190 30 266 132 30 371 177
35 394 146 45° 35 263 130 45° 35 344 142 45°
40 368 117 40 244 116 40 295 115
45 290 97 45 201 104 45 213 98
50 160 12 30° 50 136 37 30° 50 135 12 30°
55 51 7 55 85 15 55 68 7
60 34 4 0° 15° 60 51 8 0° 15° 60 34 4 0° 15°
65 15 4 65 28 6 65 16 3
70 6 4 70 5 4 70 5 3

Wide beam Metal Halide 250 W Wide beam Metal Halide 400 W Wide beam Halogen 1000 W
Efficiency 67.9% Efficiency 46.7% Efficiency 57.7%
NF C 71-121: 0.68C NF C 71-121: 0.46C NF C 71-121: 0.57C
Candela Distribution Candela Distribution Candela Distribution
0-180 90-270 150° 120° 0-180 90-270 150° 120° 0-180 90-270 150° 120°
0 301Degrees
301 105° 0 105
Degrees
105 105° 0 251
Degrees
251 105°
5 303 318 90°
5 104 106 90°
5 244 255 90°
10 299 342 10 108 130 10 247 272
15 294 387 75° 15 124 165 75° 15 245 293 75°
20 287 382 20 148 177 20 237 306
25 286 306 60° 25 167 183 60° 25 229 262 60°
30 271 237 30 165 147 30 213 213
35 231 208 45° 35 142 127 45° 35 194 188 45°
40 172 186 40 116 113 40 163 161
45 133 140 45 74 115 45 120 133
50 83 104 50 52 103 50 82 105
55 48 18 30° 55 48 40 30° 55 52 18 30°

Lighting: Explosionproof — Floodlight


60 34 8 60 44 13 60 35 8
65 23 6 65 34 9 65 20 5
0° 15° 0° 15° 0° 15°
70 6 6 70 18 6 70 8 5

Lighting

* 400 W Metal Halide: Efficiency rate lower than 250 W due to thermal deflector between glass and lamp, requested for T3.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1305


© September 2010
Explosionproof Floodlights
150 W, 300 W Reflector Incandescent

For 150 W PAR-38 or R-40 reflector lamps: For 300 W R-40 reflector lamps:
Class I, Groups C, D Class I, Group D

Applications
• Class I, Groups C and D locations such as aircraft service
areas, oil and gas loading docks, distilleries.
Features
• Floodlights feature rugged, lightweight cast aluminum
construction and are factory wired and sealed — no external
seals are required. Choice of lamp types provides various
distribution patterns. Use medium base 150W PAR-38, R-40 or
300W R40 reflector lamps.
• Easy to carry, portable model with wheelbase has handle for
convenient carrying, built-on wrench allowing 135° vertical
adjustment. Weighs 19 lbs/8.6 kgs.
• External cable on portable wheelbase unit (not furnished)
should be 3-conductor No. 16 A.W.G. type S or SO rubber
covered cable. Service end of cord should be equipped with a
2-wire, 3-pole explosionproof plug for connecting to an
explosionproof receptacle.
• Terminal block has pressure terminal for connecting rubber
covered cable to floodlight. Cable Connector takes a .375”
to .500”/9.5 to 12.7 mm outside diameter cord. Sizes up to
.625”/15.9 mm diameter are available on special order.
• Permanent base model has explosionproof junction wiring GEFWB-30
chamber with 3/4”/19.1 mm horizontal feed-thru hubs. Vertical
adjustment to 135°; horizontal to 345°.
Standard Materials
• Housing: cast aluminum
• Yoke: high-strength aluminum alloy
• Lens: thermal shock and impact resistant glass
Standard Finishes
• Floodlight housing, wheelbase, yoke and wiring compartment:
aluminum enamel finished
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E10794
• Copperfree aluminum alloy and stainless steel construction
withstands 500 hours of salt-spray test. Per MIL-F-8115C
Lighting: Explosionproof — Floodlight

GEFJB-30

EF Series Explosionproof Floodlights


For 150W incandescent medium base PAR-38 (T3C) projector spot or flood, or 150W or 300W incandescent medium base R-40 (T2C)
reflector spot or flood
Description Catalog Number
Portable Flood with Wheelbase and Handle. Accommodates .375”—.500”/9.5 mm cable. †
G-EFWB-30
Permanent Base Floodlight, for .314”/8.0 mm conduit G-EFJB-30
Lighting

† Can be furnished to accommodate cable sizes to .625”/15.9mm Dia. on special order. Cable must be ordered separately.

1306 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Explosionproof Floodlight Dimensions
150 W, 300 W Reflector Incandescent

Dimensions in Inches/Millimeters

Wheelbase Floodlight (GEFWB-30) Permanent Base Floodlight (GEFJB-30)

13.19"/
335.0 mm 10.5"/
266.7 mm

16.75"/425.5 mm
17.5"/444.5 mm

12"/ .75"/19.1 mm Hub each side


304.8 mm

3.25"/
82.6 mm

4.75"/120.7 mm 5.63"/143.0 mm

Lighting: Explosionproof — Floodlight


2.75"/
69.9 mm

G-EFJB-30
Base Dimensions Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1307


© September 2010
Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof
Lighting

Class I, Division 1 and 2, Groups C, D Suitable for Wet Locations


Class I, Division 2, Groups A, B Marine Outside Type (Saltwater)
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

Applications
Lighting: Explosionproof — Visual Signal

• Code•Master Explosionproof Strobe fixtures are designed to


provide safe operation in the presence of hazardous gases,
vapors or dusts, defined by the National Electrical Code as
Class I, Groups C and D; and Class II, Groups E, F and G.
• For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured.
• Also used in areas where audible signals cannot be heard, to
warn of unsafe conditions and for other communication needs.
Features
• Fixtures operate safely in high ambient temperatures.
• Minimum operating temperature is -13 °F/-25 °C.
• Available for fire alarm hearing impaired.
• 65 flashes per minute.
• Fixtures are complete with lamp.
• Patented “wireless” design. Threading of fixture unit
onto mounting hood makes electrical connection. The
only wiring required is attaching two wires to connection
block in mounting hood.
• Connection block is easily wired: (a) loosen two screws, (b)
make wire connections; and (c) re-position connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand by” unit.
• Acme double lead threads speed installation and fixture removal
from mounting hood. Only half as many turns are required as for
single lead threads. The threads do not stick or gall, eliminating
problems often encountered with single lead threads during Fixture (shown with optional guard) are suitable for mounting in
fixture unit removal. any position including globe up or globe down utilizing pendant,
• All threaded joints are flame-tight. ceiling or wall-bracket type mounts.
• Factory installed lens available in five colors: red, amber, blue,
green and clear (factory installed).
• Factory sealed. External seals are not required.
• Heat- and impact-resistant globes have smooth dust-resistant
exterior.
• Fixture is suitable for mounting globe up or globe down utilizing
pendant, ceiling or wall bracket type mounts.
• Optional guards protect globes from damage.
Standard Materials
• Fixture housing, mounting hoods and guards: copperfree (4/10
of 1% max.) aluminum
• Globes: prismatic glass
• Screws: Stainless steel (3)
Standard Finishes
• Fixture housing, guards and mounting hoods: epoxy power
coat finish, electrostatically applied for complete, uniform
corrosion protection
Certifications and Compliances
• UL Listed: E212210
• UL Standard: 1203
• UL Standard: 1638 Visual Signaling Appliances
• UL Standard: 1971 Visual Signaling Equipment has been
investigated for fire protective signaling services to alert hearing
impaired persons. This signaling equipment is intended to be
used in conjunction with Listed compatible units and devices.
Visual signaling equipment Listed in this category is intended to
be used in the “Public Operating Mode” as defined in NFPA 72

1308 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof

Lighting
Class I, Division 1 and 2, Groups C, D Suitable for Wet Locations
Class I, Division 2, Groups A, B Marine Outside Type (Saltwater)
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

Lighting: Explosionproof — Visual Signal


Ordering Information
Order using catalog numbering guide below or select catalog number from tables on following pages.

Catalog Numbering Guide


CS S P 75 120AC CL P

Series: Mounting Hood: Voltage Current: Options:


CS - Code•Master Signal P - Pendant 120 AC - 120 Vac P - Hearing
B - Wall bracket 240 AC - 240 Vac Impaired
C - Ceiling 250 DC - 250 Vdc (UL1971)
2030 DC - 20-30 Vdc ➊ (Strobe Only)
24 DC - 24 Vdc ➌ G - Guard
Type: Hub Size: Globe:
S - Strobe 75 – 3/4” CL - Clear
AM - Amber ➋
BL - Blue ➋
GR - Green ➋
RE - Red ➋

Thermal Suitability of Code-Master Strobe Fixture


Ambient
Temp. Class I, Division 1 and 2 Class I, Division 2 Class II, Division 1 & 2
°F/°C Groups C & D Groups A & B Class III
104/40 T6 T2B T4A
131/55 T6 T2B T4A
149/65 T6 T2A T4

Operating Temperatures
“T” Numbers Represent the Maximum Internal Temperature for Class I, Division 2 Locations; Maximum Surface Temperature for
Class I, Division 1 Locations; and Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(°F)
Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code.

➊ UL1971: Hearing-Impaired Strobe Only


➋ Not for use with UL1971 Strobe
➌ Diode Polarized (Current limiter supplied as standard).

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1309


© September 2010
Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof
Lighting

Class I, Division 1 and 2, Groups C, D Suitable for Wet Locations


Class I, Division 2, Groups A, B Marine Outside Type (Saltwater)
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
Lighting: Explosionproof — Visual Signal

Standard Strobes
Volts Catalog Number ➊➌
Pendant — One Hub 3/4” NPT, Rigid Conduit
120 Vac CSSP75120ACCL

240 Vac CSSP75240ACCL

250 Vdc CSSP75250DCCL

24 Vdc CSSP7524DCCL ➋
Ceiling — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
120 Vac CSSC75120ACCL

240 Vac CSSC75240ACCL

250 Vdc CSSC75250DCCL

24 Vdc CSSC7524DCCL ➋
Bracket — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
120 Vac CSSB75120ACCL

240 Vac CSSB75240ACCL

250 Vdc CSSB75250DCCL

24 Vdc CSSB7524DCCL ➋
Fixture Unit Only — Less Mounting Hood
120 Vac CSST120ACCL
240 Vac CSST240ACCL
10.3 lb/4.7 kg
250 Vdc CSST250DCCL
24 Vdc CSST24PDCCL ➋

Weight Hub Size (Inches) Catalog Number


Pendant Mounting Hood — One Hub 3/4” NPT, Rigid Conduit

2.0 lb/9.0 kg 3/4 CAP75

Ceiling Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

4.0 lb/1.8 kg 3/4 CAC75

Bracket Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

6.0 lb/2.7 kg 3/4 CALB75

➊ Add -G suffix for optional guard.


➋ Diode polarized (current limiter supplied as standard).
➌ Catalog numbers shown are supplied with clear lens. To order colored lens, replace last digits of catalog number CL with AM for amber; BL for blue; GR for
green; and RE for red.

1310 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof

Lighting
Class I, Division 1 and 2, Groups C, D Suitable for Wet Locations
Class I, Division 2, Groups A, B Marine Outside Type (Saltwater)
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

Lighting: Explosionproof — Visual Signal


Strobes for the Hearing Impaired
Type Mounting Volts Catalog Number — UL1971: Hearing-Impaired ➊
Pendant — One Hub 3/4” NPT, Rigid Conduit

20-30 Vdc CSSP752030DCCLP

Ceiling — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

20-30 Vdc CSSC752030DCCLP

Fixture Unit Only — Less Mounting Hood

20-30 Vdc CSSB752030DCCLP

Fixture Unit Only — Less Mounting Hood

10.3 lb/4.7 kg 20-30 Vdc CSST2030PDCCL

Weight Hub Size (Inches) Catalog Number — UL1971: Hearing-Impaired


Pendant Mounting Hood — One Hub 3/4” NPT, Rigid Conduit

2.0 lb/9.0 kg 3/4 CAP75-1971

Ceiling Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

4.0 lb/1.8 kg 3/4 CAC75-1971

Bracket Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

6.0 lb/2.7 kg 3/4 CALB75-1971

➊ Only clear globes are available for UL1971 applications.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1311


© September 2010
Code•Master™ Factory Sealed Strobe Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Lighting
Lighting: Explosionproof — Visual Signal

Description Weight Lbs/Kg Catalog Number


Optional Aluminum Guard

1.0/0.5 CJGU-15

Replacement Connection Block — Standard

For Non-Hearing-Impaired
0.5/0.2 VPT-7
CodeMaster Fixtures

Replacement Connection Block — UL1971: Hearing-Impaired

For Code-Master Fixtures for the


0.5/0.2 VPT-7P
Hearing Impaired

Replacement Lamps
Fixture Type Lamp Type Voltage Base Type Catalog Number

Xenon All Octal Socket S865

Strobe

1312 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master™ Factory Sealed Strobe Luminaire Family Tree and Dimensions
Explosionproof, Dust-Ignitionproof

Lighting
Lighting: Explosionproof — Visual Signal
Pendant Ceiling Bracket
One Hub Four Hubs Four Hubs
— Three Close-Up Plugs Three Close-Up Plugs
3/4” NPT 3/4” NPT 3/4” NPT
CAP75 CAC75 CALB75
CAP75-1971 CAC75-1971 CALB75-1971

Fixture Unit With Globe


Strobe 120AC CSST120ACCL
240AC CSST240ACCL
250DC CSST250DCCL
20-30DC CSST2030PDCCL ➊
24DC CSST24PDCCL ➋

Optional Aluminum Guard


CJGU-15

Dimensions in Inches/Millimeters
Pendant Ceiling Wall Bracket

Hub For
0.41"/
Hub for .75" 10.4 mm Dia.
2.46"/
3/4” NPT 2” Wiring access
2.28"/
NPT Conduit 62.5 mm 57.9 mm
cover both sides.
4.00"/
101.6 mm 4.25"/
4.50"/ 4.92"/
125.0 mm Sq. 108.0 mm
4.50"/ 114.3 mm
Dia.
114.3 mm 4.00"/ 1.23"/
101.6 mm
3.92"/ 31.2 mm 1.79"/
3.75"/ 5.92"/ 99.6 mm 45.5 mm
3.46"/
95.3 mm 150.4 mm 87.9 mm 11.5"/
292.1 mm
13.75"/
Hub for .75" NPT 349.3 mm
Conduit Four Sides 5.95"/
151.3 mm
13.15"/
334.0 mm 13.88"/
4.00"/
352.6 mm
101.6 mm

13.53"/ 4.92"/
125.0 mm
343.7 mm
12.38"/
13.00"/ 314.5 mm
13.38"/ 330.2 mm
339.9 mm
13.75"/
349.3 mm

7.80"/
198.1 mm

7.80"/
7.80"/ 198.1 mm
198.1 mm

➊ UL1971: Hearing-Impaired Strobe Only


➋ Diode polarized (current limiter supplied as standard).

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1313


© September 2010
TCH Series Safety Flashlights
Increased Safety

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IEC
IP66 (TCH1) IP66/68 (TCH2)

Applications
• To provide maintenance staff with task specific portable
lighting in Zone 1 hazardous areas.
• Ideal for persons requiring task specific portable lighting
in refineries, oil and gas process and chemical plants.
Lighting

Features
• Type TCH1:
— Luminescent switch facilitates locating flashlight in dark.
— Can be used to transmit a Morse code. TCH1
— Halogen version provides twice the lumen output of
incandescent lamps.
— Hook for hands free operation.
Lighting: Explosionproof — Portable

— Uses R20 or LR20 batteries (not included).


— Supplied with 1 lamp.
• Type TCH2:
— Dual optics (one at the end and one on the side) permitting:
- Focused beam for safe movement.
- Wide angle side beam for task specific focused lighting.
— Ergonomic design permits easy manipulation:
User can select one of the two beams with one hand.
— Two beams can be switched on separately and not
simultaneously. TCH2
— Should one lamp fail, the second lamp will still provide
illumination.
— Flashlight is stable when placed upright on a horizontal — Certification Type TCH2
surface. - T Rating:
— Pocket clip allows for hands free work. -4 °F/20 °C ≤ To ≤ + 104 °F/40 °C: Incandescent PR6,
— Luminescent ring allows easy locating of flashlight in dark. Krypton PR102, Halogen HPR52, Halogen HPR01 = T4
— Suspension hook for hands free use. +104 °F/40 °C ≤ To ≤ + 131 °F/55 °C: Incandescent PR6,
— Uses 2 R20 or LR20 batteries (not included). Krypton PR102, Halogen HPR01 = T4
— Supplied with one halogen lamp for main beam and one +104 °F/40 °C ≤ To ≤ + 131 °F/55 °C: Halogen HPR52 =
incandescent lamp for side beam. T3
— Supplied with one special opening tool. Ambient Temperature: -4° F/-20 °C ≤ To ≤ + 131 °F/55 °C
Standard Material - CE Declaration of Conformity: 50238
• Type TCH1: - ATEX Certificate: LCIE 02 ATEX 6229
— Housing: shockproof and antistatic polyamide - IEC Certificate: LCIE Ex 02.024
— Internal reflector: polished - Ingress Protection (solid and liquid): IP66/68 (25m)
— Lens: polycarbonate • Dust: Zone 21-22
— Hardware: stainless steel — Conforming to ATEX 94/9/CE: CE 0081 II2 D
— Switch: luminescent — ATEX/IEC Protection: Ex tD A21
• Type TCH2: — Certification Type TCH1
— Housing: black polycarbonate - Surface Temperature: 203°F/95 °C
— Internal reflector: polished - Ambient Temperature: -4°F/-20 °C ≤ To ≤ + 104°F/40 °C
— Lens: polycarbonate - CE Declaration of Conformity: 50259
— Hardware: stainless steel - ATEX Certificate: LCIE 03 ATEX 6064
— Ring: luminescent - IEC Certificate: LCIE Ex 03.010
- Ingress Protection (solid and liquid): IP66
Certifications and Compliances — Certification Type TCH2
• Gas: Zones 1–2 - Surface Temperature: 266° F/130 °C
— Conforming to ATEX 94/9/CE: CE 0081 II 2 G Ambient Temperature: -4 °F/-20 °C ≤ To ≤ + 131 °F/55 °C
— ATEX/IEC Protection: Ex eib IIC - CE Declaration of Conformity: 50238
— Certification Type TCH1 - ATEX Certificate: LCIE 02 ATEX 6229
- T Rating: T4 - IEC Certificate: LCIE Ex 02.024
- Ambient Temperature: -4 °C/20 °C ≤ To ≤ + 104°F/40 °C - Ingress Protection (solid and liquid): IP66/68 (25m)
- CE Declaration of Conformity: 50259 • Ex Standards: EN/IEC 60079-0; 60079-7; 60079-11; 61241-0;
- ATEX Certificate: LCIE 03 ATEX 6064 61241-1
- IEC Certificate: LCIE Ex 03.010 • Product Standards: EN/IEC 60598-1
- Ingress Protection (solid and liquid): IP66 • Other Standards: EN/IEC 60529 (IP)

1314 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
TCH Series Safety Flashlights
Increased Safety

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IEC
IP66 (TCH1) IP66/68 (TCH2)

Ordering Information:
Number of
lamps Type of Lamps Number of Weight Volume Catalog
(included) (not included) Battery Cells lbs/kgs in3/dm3 Number Pack

Lighting
Incandescent
TCH12C
1 2.5 V – 0.3 A 2 0.88/0.4 207.6/3.4 2
Incandescent
TCH13C
1 3.7 V – 0.3 A 3 0.88/0.4 207.6/3.4 2
Halogen
TCH12H
1 2.8 V – 0.5 A 2 0.88/0.4 207.6/3.4 2

Lighting: Explosionproof — Portable


Incandescent
2.5 V – 0.3 A
2 2 0.88/0.4 116.0/1.9 TCH22M 1
Halogen
2.8 V – 0.5 A

Spare Lamps for Replacement (Lamp Holder P13,5S)


Type of lamp Rating Catalog Number Pack
Incandescent (PR6) 2.5 V – 0.3 A TCHL25C 10
Incandescent (PR6) 3.7 V – 0.3 A TCHL37C 10
Halogen (HPR01) 2.8 V – 0.5 A TCHL28H 10

Dimensions in Inches/Millimeters

182
7.2/182.0 244
9.6/244.0 213
8.4/213.0
44

27
Ø2.8/72.0
Ø2.4/60.0

Ø2.8/70.0
Ø2.4/60.0
60

70

72
60

48
28
1.1/28.0
TCH12C/H TCH13C
1.4/35.0
35

44
Ø1.7/44.0 TCH22M

Photometric Data

Catalog Number TCH12C (at 25 meters) Incandescent Catalog Number TCH13C (at 25 meters) Incandescent

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1315


© September 2010
AHL and EHL Incandescent Factory Sealed Luminaires and Handlamps
Explosionproof
Suitable for use in Wet Locations.

AHL EHL
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F ➊, G
Class III

Applications
• AHL general purpose explosionproof lighting fixture – an
A-51 fixture with handle assembly of hook and cable clamp.
CAUTION: For safe operation, the AHL fixture weight must be
supported by the hanger hook, not by the flexible cord, per the
Lighting

National Electrical Code.


• EHL general purpose explosionproof portable handlamp. Only
5”/127 mm in diameter for ease of movement.
Features:
• AHL and EHL
– Equipped with connection block for ease of wiring
and relamping.
Lighting: Explosionproof — Portable

– Cable clamp diameters: AHL – .375” to .625”/9.5 mm to 15.9


mm; EHL – .406”/10.3 mm for 16-3 AWG.
– Heat- and impact-resistant glass globes.
• AHL AHL
– Sturdy fixture with rugged hanging hook.
– Safety grounding – additional terminal furnished to connect to
grounding conductor.
• EHL
– Portability, with phenolic handle and non-sparking guard
with hook.
– Easy relamping – loosen setscrew, unscrew guard, remove
globe and insert lamp.
– Safety grounding – remove cable and clamp and make
connections to terminal (including one ground terminal) then EHL
tighten clamp.
Standard Materials
• Globes: heat-and impact-resistant glass
• AHL fixture unit, hook and guard: copperfree aluminum
• AHL cable clamp: brass
• EHL fixture body and handle: laminated phenolic
• EHL handle: laminated phenolic
• EHL hook: brass
• EHL guard: copperfree aluminum
Standard Finishes
• AHL fixture unit, guard, handle and hook: two-coat
epoxy enamel
• AHL cable clamp: natural finish
• EHL fixture body: laminated phenolic
• EHL handle: phenolic
• EHL guard and hook: guard – natural finish; hook – zinc
electroplate and clear chromate
• EHL cable clamp: laminated phenolic
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• EHL UL Listed: E59147
• CSA Certification: LR25428
Related Products
• The EHL handlamp may be used with AE Automatic Take-
Up Reelites listed in the Specialty Products section and ECC
Cord Connector and Plugs and Receptacles in the Plug and
Receptacles section.

➊ To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are not electrically
conductive).

1316 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
AHL and EHL Incandescent Factory Sealed Luminaires and Handlamps
Explosionproof
Suitable for use in Wet Locations.

AHL EHL
Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F ➊, G
Class III

Cable Diameter “T” Catalog


Description (Inches) Ratings Number
AHL – Explosionproof 60 - 300 W Lighting Fixtures
CAUTION: For safe operation, weight of fixture must be supported by hanger hook, not by the flexible cord, per the National Electrical Code.

Lighting
60-100 W, A-21 (AAU-1N) .375 to .625 T4 AHL100

200-300 W, PS-30 (AAU-2NS) .375 to .625 T4A AHL200

Lighting: Explosionproof — Portable


EHL – Explosionproof 100 W Portable Handlamp ➋
Laminated Phenolic Handle. Wiring Connection Block takes from #16 to #14 Wire.

100 W, A-21 .406 T3A EHL100N

EHL Replacement Globe and Guard

Heat-resistant glass globe XP419

Aluminum guard with hook XP163SA

Dimensions in Inches/Millimeters
AHL EHL
6.50"/
165.1 mm

7.50"/
190.5 mm
3.31"/84.1 mm
17.63"/447.8 mm

A
C 4.88"/124.0 mm
Dia.

Catalog Number A B C
AHL100 14.25/362.0 7.06/179.3 10.94/277.9
AHL200 15.94/404.9 8.81/223.8 12.63/320.8

➊ To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are not electrically
conductive).
➋ Handlamp accommodates 16-3 SO cable. Contact your sales representative if 14-3 cable is required.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1317


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D Suitable for use in Wet Locations


Class II, Division 1 and 2, Groups E, F, G NFPA101, Life Safety Code
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)

Applications
• Ideal for use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries; and
in other process areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
• Suitable for use in wet locations.
Features
• Auxiliary (emergency) lighting should be used to provide a
lighted means of egress for personnel in walkways, catwalks,
stairs, doorways, tunnels, ramps and aisles.
• Auxiliary (emergency) lighting should be used to provide “instant
on” illumination during power failures.
• Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation. Illustrated Features
• Safe, easy servicing without disconnecting any wiring. Patented
Lighting

“wireless” design means the threading of the fixture unit onto


mounting hood makes electrical connection. This allows for the
fixture unit to easily thread off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
Only wiring required is attaching two wires to connection block
in mounting hood.
• Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block.
Lighting: Explosionproof — Emergency

• Acme double-lead threads speed installation and fixture


removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single-lead threads during fixture unit removal.
• All threaded joints are flame-tight.
• Factory sealed. External seals not required.
• Fluorescent light source reduces energy costs.
• Fluorescent lamp life of 10,000 hours reduces relamping costs
compared to incandescent.
• Strategic location of lamp sockets in combination with the • Remote “Push-To-Test” switch is available to verify emergency
interior prism design of the glass globe provides optimum light operation (order separately, see F3-82).
distribution and control. • Red indicator light is provided with each battery pack to
• Superior corrosion resistance with epoxy powder coat finish. indicate when the battery is charging.
• Choice of mountings: pendant, ceiling, bracket and stanchion.
• Fiberglass-reinforced polyester reflectors in standard
Standard Materials
dome, deep dome or 30° angle are ideal in installations • Ballast bodies, guards and pendant mounting hoods:
where luminaire is subject to exceptionally severe corrosive copperfree (4/10 of 1% max.) aluminum
atmospheres. The high bay aluminum reflector is designed for • Ceiling, bracket and stanchion mounting hoods: sand-cast
installations where mounting height work planes range from copperfree (4/10 of 1% max.) aluminum
20 to 30 feet/6 to 9 meters. • Reflectors: aluminum or fiberglass reinforced polyester
• Optional guards protect globes from damage. Guards secure to Standard Finishes
fixture with three screws.
• Fixture (52, 64 or 84 W) is available for semi-continuous • Ballast bodies, guards and mounting hoods: epoxy powder
operation (one AC ballast permits two-lamp illumination when coat finish, electrostatically applied for complete, uniform
power is on and one battery pack permits one-lamp illumination corrosion protection
when AC power is interrupted). Options
• Minimum operating temperature: 32 °F/0 °C. • Fuse kit CF2 for field installation.
• Maximum operating temperature: 104 °F/ 40 ° C
Certifications and Compliances
Battery Pack Information
• UL Standard: UL 924, UL 844, UL 1598
• Long life, high temperature, nickel-cadmium (Ni-Cad) battery. • UL Listed: E165014
• Dual voltage (120/277 V, 60 Hz) solid state charger on open
circuit board.
• Five-year life expectancy.
• Wiring instructions for “Push-To-Test” button are supplied
with fixture.

1318 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Technical Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D Suitable for use in Wet Locations


Class II, Division 1 and 2, Groups E, F, G NFPA101, Life Safety Code
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)

Classified Area Suitability of Code•Master 2 Emergency Series (Suitability includes use of reflector.)
Class I, Division 1 & 2 Class II, Division 1 & 2
With Globe or with Globe & Reflector With Globe or with Globe & Reflector
Ambient UL/NEC Temp. Ident. No. UL/NEC Temp. Ident. No.
Lamp Lamps Temp ˚ Nameplate Nameplate
Type Watts °F/°C Marking Groups Marking Groups
52 104/40 T6 C,D T4 E,F,G
PLT 64 104/40 T6 C,D T4 E,F,G
84 104/40 T6 C,D T4 E,F,G

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.

Lighting
“T”
Number
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6

Temp.
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 842 185
662 617 572 536 500 446 419 392 356 329 320 275 248 212
(°F)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-

Lighting: Explosionproof — Emergency


Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°˚C)

Fixture and Accessory Weights in Lbs/kg


Fixture Size Fixture Weight Reflector Weight Guard Weight
52 W 45/20.4 3/1.4 2/0.9
64 W 45/20.4 3/1.4 2/0.9
84 W 45/20.4 3/1.4 2/0.9

Mounting Hood Weights Lbs/kg


Pendant Ceiling Bracket Stanchion
2/0.9 4/1.8 6/2.7 2/0.9

Electrical Specification for AC Operation


Catalog Fixture Line Frequency Type of Line Maximum Wattage
Number ➊ Wattage Voltage (V) (Hz) Ballast Amps (A) (W/W)
CMBFS5212 52 120 60 PLT Electronic 0.49 52
CMBFS5227 52 277 60 PLT Electronic 0.20 52
CMBFS6412 64 120 60 PLT Electronic 0.57 64
CMBFS6427 64 277 60 PLT Electronic 0.24 64
CMBFS8412 84 120 60 PLT Electronic 0.73 84
CMBFS8427 84 277 60 PLT Electronic 0.31 84

➊ For optional fusing. order kit -CF2

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1319


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D Suitable for use in Wet Locations


Class II, Division 1 and 2, Groups E, F, G NFPA101, Life Safety Code
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)

Lamp Watts Lamp Type Hub Size (Inches) Catalog Number ➋➌


Pendant
3/4 CFPS5275
52 PLT
1 CFPS5210
3/4 CFPS6475
64 PLT
1 CFPS6410
3/4 CFPS8475
84 PLT
1 CFPS8410

Ceiling
3/4 CFCS5275
52 PLT
Lighting

1 CFCS5210
3/4 CFCS6475
64 PLT
1 CFCS6410
3/4 CFCS8475
84 PLT
1 CFCS8410
Lighting: Explosionproof — Emergency

Bracket
3/4 CFBS5275
52 PLT
1 CFBS5210
3/4 CFBS6475
64 PLT
1 CFBS6410
3/4 CFBS8475
84 PLT
1 CFBS8410

25° Stanchion

52 PLT 1-1/4 or 1-1/2 ➊ CFSS52150

64 PLT 1-1/4 or 1-1/2 ➊ CFSS64150

84 PLT 1-1/4 or 1-1/2 ➊ CFSS84150

Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to Fixture Unit catalog number listed below.
Add Voltage Suffixes
Lamp Watts Lamp Type Unit Catalog Number 120 V 277 V
52 PLT CMBFS52 12 27

64 PLT CMBFS64 12 27

84 PLT CMBFS84 12 27

➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.


➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ Add voltage suffix -12L for 120 V with lamp; or -27L for 277 V with lamp.

1320 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Mounting Hoods

Hub Size Inches Catalog Number


Pendant

3/4 CAP-75
One Hub
1 CAP-100

Ceiling

3/4 CAC-75
Four hubs,
Three Close-Up Plugs
1 CAC-100

Lighting
Bracket

3/4 CALB-75
Four hubs,
Three Close-Up Plugs
1 CALB-100

Lighting: Explosionproof — Emergency


25° Stanchion

One Hub 1-1/4 or 1-1/2 ➊ CAS-150

Mounting Adapter with Connection Block

Permits use of existing A-51 mounting hoods (AAC Ceiling or AALB


Bracket) with the new Code•Master 2 Fixture Unit. After removing existing
CMAD-1
Fixture Unit and adapter, screw in the new CMAD-1 Adapter. Then thread
thenew Fixture Unit into the CMAD-1.

➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1321


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Description Catalog Number


Polyester Reflectors

Standard Dome CMR-4ST

Deep Dome CMR-4DD

30˚ Angle CMR-4AN

Aluminum High Bay Reflectors


Lighting

CMR-4HB

Prismatic Glass Globes


Lighting: Explosionproof — Emergency

52, 64, 84 W PLT CGL-400

Aluminum Guards

52, 64, 84 W PLT CGU4

Connection Block — For Code•Master 2 PLT Fixtures

52 W - 84 W PLT32RS

52 W - 84 W VPT-7

1322 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Dimensions in Inches/Millimeters

Pendant Ceiling Bracket 25° Stanchion


.390"/ 0.41"/
9.9 mm 10.4 mm Dia. 9.5"/
2.46"/ 2.28"/ 241.3 mm
62.5 mm 57.9 mm
6.10"/
154.9 mm
4.58"/
116.3 mm 4.00"/
4.92"/ 4.25"/
Dia. 101.6 mm
125.0 mm Sq.
3.46"/ 108.0 mm 4.5"/
87.9 mm 60.5 mm
Dia.
3.91"/99.3 mm 3.92"/
1.23"/
4.00"/
99.6 mm
31.2 mm 1.79"/ 2.38"/
101.6 mm 45.5 mm 60.5 mm Dia.
5.92"/
150.4 mm 11.5"/
250.4 mm

292.1 mm
.94"/
9.86"/

23.9 mm 13.75"/
349.3 mm

4.00"/
101.6 mm
250.4 mm

Lighting
9.86"/

250.4 mm
9.86"/

Lighting: Explosionproof — Emergency


5.50"/
139.7 mm

Pendant Ceiling Bracket 25° Stanchion


A B C D A B C D A B C D A B C
24.50/ 23.50/ 12.00/ 20.36/ 24.36/ 23.36/ 12.00/ 20.36/ 24.61/ 23.61/ 17.50/ 20.36/ 22.20/ 21.20/ 17.50/
52-84 W 622.3 596.9 304.8 517.1 618.7 593.3 304.8 517.1 625.1 599.7 444.5 517.1 563.9 538.5 444.5

Reflector Dimensions in Inches/Millimeters


Type Reflector A B C Standard and Deep Dome 30° Angle High Bay
11.20/ 5.90/ 18.70/
Standard Dome 284.5 149.9 475.0 10.96"/
278.4 mm
10.56"/
10.56/ 7.00/ 20.30/ 268.2 mm
Deep Dome 268.2 177.8 515.6
9.75”/ 13.30"/
347.7 mm
337.8 mm

16.16"/
410.5 mm

20.80"/
528.3 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1323


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

* Photometric data is based on a fixture PL-T Lamps. (3,200 lumens each) multiply by
with two 32 W Compact Fluorescent PL-T 1.34.
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

Total Luminaire Efficiency = 79.8%


CIE Type - Semi-Direct REPORT NUMBER: CMBF64G
Spacing 64 W (two 32 W lamps) Fluorescent Fixture with Globe only *
Plane Criteria
0-180 2.88 Coefficients of Utilization - Zonal Cavity Method
90-270 2.88 Effective Floor Cavity Reflectance 0.20
Diagonal 2.82 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 90 90 90 90 85 85 85 85 76 76 76 68 68 68 60 60 60 57
0-10 17.70 1 76 70 65 60 71 66 61 57 58 54 51 51 48 45 45 42 40 36
10-20 61.05 2 67 58 51 45 63 55 48 42 48 43 38 42 37 34 36 32 29 26
20-30 132.44 3 60 49 41 35 56 46 39 33 40 34 29 35 30 26 30 26 23 20
30-40 236.78 4 54 43 34 28 50 40 32 26 35 28 23 30 25 21 26 21 18 15
40-50 336.66 5 49 37 29 23 46 35 27 22 31 24 19 26 21 17 23 18 15 12
Lighting

50-60 421.68 6 45 33 25 19 42 31 23 18 27 21 16 23 18 14 20 16 12 10
60-70 485.34 7 41 29 22 16 38 28 20 15 24 18 14 21 16 12 18 14 10 8
70-80 517.29 8 38 26 19 14 36 25 18 13 22 16 12 19 14 10 16 12 9 7
80-90 513.72 9 35 24 17 12 33 23 16 11 20 14 10 17 12 9 15 11 8 9
90-100 468.70 10 33 22 15 11 31 21 14 10 18 13 9 16 11 8 14 10 7 5
100-110 352.77
110-120 200.85 Zonal Lumen Summary
Lighting: Explosionproof — Emergency

120-130 73.54 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 11.28 0-30 211.19 4.4 5.5 90-120 1022.32 21.3 26.7
Maximum Candela = 493
140-150 1.12 Located at Horizontal Angle = 0, Vertical Angle = 70 0-40 447.97 9.3 11.7 90-130 1095.85 22.8 28.6
150-160 0.31 #1 – Vertical Plane through Horizontal Angles (0-180) 0-60 1206.31 25.1 31.5 90-150 1108.26 23.1 28.6
(Through Max. Cd.)
160-170 0.06 #2 – Horizontal Cone through Vertical Angle (70) 0-90 2722.64 56.7 71.1 90-180 1108.63 23.1 28.9
170-180 0.00 (Through Max. Cd.) 0-180 3831.28 79.8 100.0

Total Luminaire Efficiency = 66.5%


REPORT NUMBER: CMBF64ST
CIE Type - Direct
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Spacing
Plane Criteria Standard Dome Reflector *
0-180 1.62 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.74 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 79 79 79 79 77 77 77 77 74 74 74 71 71 71 68 68 68 66
0-10 73.25 1 72 69 66 63 70 67 64 62 64 62 60 62 60 58 59 58 56 55
10-20 220.57 2 65 59 54 50 63 58 53 49 55 52 48 53 50 47 51 48 46 45
20-30 368.60 3 59 51 45 41 57 50 45 40 48 43 40 46 42 39 44 41 38 37
30-40 505.61 4 53 45 38 34 52 44 38 33 42 37 33 40 36 32 39 35 32 30
40-50 603.19 5 49 39 33 28 47 39 33 28 37 32 28 36 31 28 35 31 27 26
50-60 638.42 6 45 35 29 24 43 34 29 24 33 28 24 32 27 24 31 27 23 22
60-70 497.24 7 41 32 25 21 40 31 25 21 30 25 21 29 24 21 28 24 20 19
70-80 226.17 8 38 29 23 19 37 28 22 18 27 22 18 26 22 18 26 21 18 17
80-90 57.98 9 35 26 20 16 34 26 20 16 25 20 16 24 19 16 23 19 16 15
90-100 1.64 10 33 24 18 15 32 24 18 15 23 18 15 22 18 15 22 17 14 13
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 662.42 13.8 20.7 90-120 1.64 0.0 0.1
Maximum Candela = 808
140-150 0.00 Located at Horizontal Angle = 0, Vertical Angle = 35 0-40 1168.03 24.3 36.6 90-130 1.64 0.0 0.1
150-160 0.00 #1 – Vertical Plane through Horizontal Angles (0-180) 0-60 2409.64 50.2 75.5 90-150 1.64 0.0 0.1
(Through Max. Cd.)
160-170 0.00 #2 – Horizontal Cone through Vertical Angle (35) 0-90 3191.04 66.5 99.9 90-180 1.64 0.0 0.1
170-180 0.00 (Through Max. Cd.) 0-180 3192.68 66.5 100.0

1324 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

* Photometric data is based on a fixture PL-T Lamps. (3,200 lumens each) multiply by
with two 32 W Compact Fluorescent PL-T 1.34.
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

Total Luminaire Efficiency = 57.4%


REPORT NUMBER: CMBF64AN
CIE Type - Direct
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Spacing
Plane Criteria
30° Angle Dome Reflector *
0-180 1.52 Coefficients of Utilization - Zonal Cavity Method
90-270 1.70 Effective Floor Cavity Reflectance 0.20
Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 68 68 68 68 67 67 67 67 64 64 64 61 61 61 58 58 58 57
0-10 62.13 1 61 58 55 52 59 56 54 51 54 51 49 51 49 48 49 48 46 45
10-20 187.93 2 55 49 45 41 53 48 44 40 46 43 39 44 41 39 42 40 38 36
20-30 317.49 3 50 43 37 33 48 42 37 33 40 36 32 38 35 32 37 34 31 30
30-40 428.14 4 45 37 32 28 44 37 31 27 35 31 27 34 30 27 32 29 26 25
40-50 471.22 5 41 33 28 23 40 32 27 23 31 27 23 30 26 23 29 25 22 21

Lighting
50-60 454.23 6 38 30 24 20 37 29 24 20 28 23 20 27 23 20 26 22 19 18
60-70 384.77 7 35 27 21 18 34 26 21 18 25 21 17 24 20 17 24 20 17 16
70-80 276.31 8 32 24 19 16 32 24 19 15 23 19 15 22 18 15 22 18 15 14
80-90 157.68 9 30 22 17 14 29 22 17 14 21 17 14 20 16 14 20 16 13 12
90-100 13.45 10 28 20 16 12 28 20 15 12 19 15 12 19 15 12 18 15 12 11
100-110 0.00
110-120 0.00 Zonal Lumen Summary

Lighting: Explosionproof — Emergency


120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 567.55 11.8 20.6 90-120 13.45 0.3 0.5
Maximum Candela = 731
140-150 0.00 Located at Horizontal Angle = 90, Vertical Angle = 37.5 0-40 995.69 20.7 36.2 90-130 13.45 0.3 0.5
150-160 0.00 #1 – Vertical Plane through Horizontal Angles (90-270) 0-60 1921.14 40.0 69.8 90-150 13.45 0.3 0.5
(Through Max. Cd.)
160-170 0.00 #2 – Horizontal Cone through Vertical Angle (37.5) 0-90 2739.90 57.1 99.5 90-180 13.45 0.3 0.5
170-180 0.00 (Through Max. Cd.) 0-180 2753.35 57.4 100.0

Total Luminaire Efficiency = 67.2%


REPORT NUMBER: CMBF64DD
CIE Type - Direct
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Spacing
Plane Criteria Deep Dome Reflector *
0-180 1.44 Coefficients of Utilization - Zonal Cavity Method
90-270 1.44 Effective Floor Cavity Reflectance 0.20
Diagonal 1.60 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 80 80 80 80 78 78 78 78 75 75 75 71 71 71 69 69 69 67
0-10 88.95 1 73 70 67 65 71 68 66 63 66 63 61 63 61 60 60 59 58 56
10-20 260.61 2 66 61 56 52 65 59 55 52 57 53 50 55 52 49 53 50 48 47
20-30 413.34 3 60 53 47 43 59 52 47 43 50 45 42 48 44 41 46 43 40 39
30-40 539.82 4 55 47 41 36 53 46 40 36 44 39 35 42 38 35 41 37 34 33
40-50 630.36 5 50 41 35 31 49 41 35 30 39 34 30 38 33 30 37 33 29 28
50-60 641.74 6 46 37 31 26 45 36 30 26 35 30 26 34 29 26 33 29 25 24
60-70 436.60 7 43 33 27 23 41 33 27 23 32 27 23 31 26 23 30 26 22 21
70-80 164.84 8 40 30 24 20 38 30 24 20 29 24 20 28 23 20 27 23 20 19
80-90 47.37 9 37 28 22 18 36 27 22 18 26 21 18 26 21 18 25 21 18 16
90-100 1.92 10 34 25 20 16 34 25 20 16 24 19 16 24 19 16 23 19 16 15
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 762.91 15.9 23.7 90-120 1.92 0.0 0.1
Maximum Candela = 933
140-150 0.00 Located at Horizontal Angle = 0, Vertical Angle = 7.5 0-40 1302.73 27.1 40.4 90-130 1.92 0.0 0.1
150-160 0.00 #1 – Vertical Plane through Horizontal Angles (0-180) 0-60 2574.82 53.6 79.8 90-150 1.92 0.0 0.1
(Through Max. Cd.)
160-170 0.00 #2 – Horizontal Cone through Vertical Angle (7.5) 0-90 3223.63 67.2 99.9 90-180 1.92 0.0 0.1
170-180 0.00 (Through Max. Cd.) 0-180 3225.55 57.4 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1325


© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

* Photometric data is based on a fixture PL-T Lamps. (3,200 lumens each) multiply by
with two 32 W Compact Fluorescent PL-T 1.34.
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

Total Luminaire Efficiency = 58.9%

CIE Type - Direct REPORT NUMBER: CMBF64HB


Spacing 64 W (two 32 W lamps) Fluorescent Fixture with Globe and High Bay Reflector *
Plane Criteria

0-180 0.82 Coefficients of Utilization - Zonal Cavity Method

90-270 0.82 Effective Floor Cavity Reflectance 0.20

Diagonal 0.92 % Ceiling Rcc 80 70 50 30 10 0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Zone Lumens 0 70 70 70 70 68 68 68 68 65 65 65 63 63 63 60 60 60 59
0-10 239.15 1 66 64 63 61 65 63 62 60 61 59 58 58 57 57 56 56 55 54
10-20 599.67 2 62 59 56 54 61 58 55 53 56 54 52 54 52 51 52 51 50 49
Lighting

20-30 645.20 3 58 54 51 48 57 53 50 47 51 49 47 50 48 46 49 47 45 44
30-40 625.54 4 55 50 46 43 54 49 45 43 48 44 42 46 44 42 45 43 41 40
40-50 452.95 5 51 46 42 39 50 45 41 39 44 41 38 43 40 38 42 39 37 36
50-60 185.71 6 48 42 38 35 47 42 38 35 41 37 35 40 37 35 39 36 34 33
60-70 58.40 7 46 39 35 32 45 39 35 32 38 35 32 37 34 32 37 34 32 31
Lighting: Explosionproof — Emergency

70-80 15.26 8 43 37 33 30 42 36 32 30 36 32 30 35 32 29 34 31 29 28
80-90 4.25 9 41 34 30 28 40 34 30 28 33 30 27 33 30 27 32 29 27 26
90-100 0.69 10 38 32 28 26 38 32 28 26 31 28 26 31 28 25 30 27 25 25
100-110 0.00

110-120 0.00 Zonal Lumen Summary

120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 1484.03 30.9 52.5 90-120 0.69 0.0 0.0
140-150 0.00 0-40 2109.57 43.9 74.6 90-130 0.69 0.0 0.0
Maximum Candela = 2540
150-160 0.00 Located at Horizontal Angle = 0, Vertical Angle = 5 0-60 2748.23 57.3 97.2 90-150 0.69 0.0 0.0
#1 – Vertical Plane through Horizontal Angles (0-180)
160-170 0.00 (Through Max. Cd.) 0-90 2826.12 58.9 100.0 90-180 0.69 0.0 0.0
#2 – Horizontal Cone through Vertical Angle (5)
170-180 0.00 (Through Max. Cd.) 0-180 2628.80 58.9 100.0

1326 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Class I, Division 1 and 2, Groups B*, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• ELS Series features an emergency lighting power unit that is
designed to provide safe operation in the presence of hazardous
gases, vapors or dusts, defined by the National Electrical Code
as Class I, Groups C and D, and Class II, Groups E, F and G.
• Typical applications include all means of egress (such as
walkways, exit ramps, stairs and aisles) for hazardous areas
which include oil refineries, petrochemical facilities, pulp and
paper mills, chemical storage areas, wastewater treatment
facilities and grain elevators.
Features
• The electronics consist of a solid-state charger, transfer circuit
and low-voltage battery disconnect circuit.
• The unit test switch and AC “On” indicator light are housed in
a separate module that may be attached directly to the unit
housing or mounted remotely for ease of testing.

Lighting
• All ELS Series units are rated for operation in NEC Class I,
Division 1 and 2, Groups C and D; and Class II, Division 1 and 2,
Groups E, F, and G environments.
• Housing provisions allow for the attachment of two optional
explosionproof lighting fixtures.
• Unit capacity is sufficient for the connection of up to four 6- or
12- volt, 18-watt fixtures.
• Units provide 90 minutes of emergency operation.

Lighting: Explosionproof — Emergency


• The solid-state charger maintains battery at full charge.
• Upon failure of utility voltage, the DC emergency lighting load is
connected to the battery.
• During emergency operation, automatic battery protection from
deep discharge damage is provided by a low-voltage battery
disconnect (LVD) circuit.
• Upon restoration of normal power, the charger will begin a
recharge cycle. It will bring the battery to full capacity within
acceptable UL time standards. Standard Materials
• A pilot light indicates the presence of AC line voltage, and a test • Battery enclosure, fixtures, guards and pendant mount:
switch is provided for checking transfer operation. Lock-out copperfree (4/10 of 1% max.) aluminum.
type guard on push button accepts locks with up to 1/4”/6.5 • Ceiling and bracket mounts: malleable iron with aluminum
mm hasp. adapter
• A universal transformer allows operation on 120 or 277 Vac • Reflectors: porcelain enameled steel
lines. • Test Switch: copperfree (4/10 of 1% max.) aluminum with
• Emergency power source is a maintenance-free, sealed, stainless steel hardware
pure-lead battery suited for harsh temperature environments
for 32 °F to 104 °F/0 °C to 40 °C.
Standard Finishes
— Never necessary to add water. • Enclosure, fixtures and test station: epoxy powder coat
— Expected life is 10 years finish electrostatically applied for complete and uniform
— Compact in design surface protection
• Standard illumination is provided during power failure only using • Reflectors: white porcelain enamel
fixtures specially designed for emergency lighting in hazardous Options
environments, supplied with double contact bayonet base 18-
• The fixture may be adapted to serve as an exit sign through use
or 28-watt incandescent lamps.
of an Auxiliary Exit Housing.
• Designed for easy installation. Provided with 4 mounting holes
• Time Delay Relay (15 minutes) available to permit normal
for attachment to a wall or other suitable surface. Mounting
lighting to re-establish brightness. Add suffix -T1 for 120 Vac, or
hardware not included.
-T2 for 277 Vac.
• Housing is drilled and tapped for installation of utility
1/2”/12.7 mm NPT conduit. Certifications and Compliances
• Quick access to internal wiring and components is provided • UL Standard: UL 924, UL 844, UL 1598
by thread-on cover. • UL Listed: 175025
• All necessary fittings for test switch/ pilot light module
supplied standard.

* Contact your sales representative for Class I, Group B rating.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1327


© September 2010
ELS Series Emergency Lighting System Technical Data
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Class I, Division 1 and 2, Groups B*, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
ELS 2 18 6 T1G

Series: Wattage per lamp Options


18 – 18 W T1 – Time delay relay, 120
28 – 28 W Vac input
T2 – Time delay relay, 277
Vac input
G – Guard installed on
fixture
Number of direct mounted fixtures Lamp Voltage
0 – no direct mounted fixtures 6 – 6 Vdc
1 – 1 direct mounted fixture 12 – 12 Vdc
2 – 2 direct mounted fixtures
Lighting

Capacity of standard ELS unit (75 W for 90 minutes)


Up to 2 fixtures may be direct mounted. The remainder must be remote mounted.
Combination Number of Wattage per Total
Number Fixtures Fixture Wattage
Lighting: Explosionproof — Emergency

1 1 18 18
2 1 28 28
3 2 18 36
4 2 28 56
5 3 18 54
6 1 28 64
6 2 18 64
7 4 18 72

Lamp Supply Wire Temp Ambient Temp Class I, Division 1 & 2 Class II, Division 1 & 2 (Groups E, F & G)
Watts °F/°C °F/°C Operating Temperature Operating Temperature
18 257/125 104/40 T5 T3C
28 257/125 104/40 T5 T3C

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code. Operating temperatures are with and without reflectors and guards.

“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp
664- 619- 574- 538- 502- 448- 421- 394- 358- 331- 322- 277- 250- 214- 187-
Range 185
842 662 617 572 536 500 446 419 392 356 329 320 275 248 212
(°F)
Temp.
351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
Range 85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
(°C)

* Contact your sales representative for Class I, Group B rating.

1328 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Emergency Lighting System with Direct Mounted Fixtures


Catalog Number
Number of Fixtures Watts per Lamp Lamp Voltage Input Voltage (Lamp(s) Included)
2 18 6 Vdc 120/277 Vac ELS2186 ➊➋➌➍
2 28 6 Vdc 120/277 Vac ELS2286 ➊➋➌➍
2 18 12 Vdc 120/277 Vac ELS21812 ➊➋➌➍
2 28 12 Vdc 120/277 Vac ELS22812 ➊➋➌➍
1 18 6 Vdc 120/277 Vac ELS1186 ➋➌➍
1 28 6 Vdc 120/277 Vac ELS1286 ➊➋➌➍
1 18 12 Vdc 120/277 Vac ELS11812 ➊➋➌➍
1 28 12 Vdc 120/277 Vac ELS12812 ➊➋➌➍

Lighting
Emergency Lighting System Enclosure with Battery and Charger

Catalog Number

Lighting: Explosionproof — Emergency


with Push-to-Test
Lamp Voltage Input Voltage (Incl. Fittings)
6 Vdc 120/277 Vac ELS06 ➊➋➌
12 Vdc 120/277 Vac ELS012 ➊➋➌

Emergency Lighting System Fixture for Direct Mounting to Enclosure Includes all necessary fittings and lamp.
Watts Per Lamp Catalog Number
Lamp Voltage (Lamp Included)
18 6 Vdc AP1050-186-DM ➍
28 6 Vdc AP1050-286-DM ➍
18 12 Vdc AP1050-1812-DM ➍
28 12 Vdc AP1050-2812-DM ➍

➊ 1/2” NPT provided for AC input.


➋ Add suffix T1 for time delay relay for 120 Vac input.
➌ Add suffix T2 for time delay relay for 277 Vac input.
➍ To order fixtures with guard installed add suffix G. Reflectors and exit signs are ordered separately. See Accessories page.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1329


© September 2010
ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Emergency Lighting System Fixture for Remote Mounting — Lamp Included — Shown with Optional Guard
Mounting Watts Per Lamp Catalog Number
Type Lamp Voltage (Lamp Included) ➊
Pendant — One 1/2” Hub
18 6 Vdc AP1050-186
28 6 Vdc AP1050-286
18 12 Vdc AP1050-1812
28 12 Vdc AP1050-2812

Ceiling — Four 1/2” Hubs, Three Close-Up Plugs


Lighting

18 6 Vdc AC1050-186
28 6 Vdc AC1050-286
18 12 Vdc AC1050-1812
28 12 Vdc AC1050-2812
Lighting: Explosionproof — Emergency

Long Bracket — Four 1/2” Hubs, Three Close-Up Plugs


18 6 Vdc ALB1050-186
28 6 Vdc ALB1050-286
18 12 Vdc ALB1050-1812
28 12 Vdc ALB1050-2812

Short Bracket — 15 degrees — Two 1/2” Hubs, One Close-Up Plug


18 6 Vdc ASB1050-186
28 6 Vdc ASB1050-286
18 12 Vdc ASB1050-1812
28 12 Vdc ASB1050-2812

Emergency Lighting System Replacement Fixtures — Lamp included — Fits existing mounting hood
Watts Per Lamp Catalog Number
Lamp Voltage (Lamp Included) ➊
18 6 Vdc AAU1N-186
28 6 Vdc AAU1N-286
18 12 Vdc AAU1N-1812
28 12 Vdc AAU1N-2812

➊ To order fixtures with guard installed, add suffix G. Reflectors and exit signs are ordered separately. See Accessories page.

1330 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
ELS Series Emergency Lighting System Accessories
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Description Catalog Number


Guard

AAGU1

Three-Way Exit Sign

Epoxy enameled steel — 6”-high red lettering


CJEXRN
Mounts to fixture units in place of guard.

Lighting
Single-Sided Exit Sign

Epoxy enameled steel — 6”-high red lettering


AEXR-15R
Mounts to fixture units in place of guard.

30° Angle Reflector

Lighting: Explosionproof — Emergency


AARW15AN

Standard Dome Reflector

AARW15ST

Push-to-Test Station
Complete Push-to-Test Station EFDCB150J1U1-T-A
Cover with Switch and Pilot Light EFKB-J1U1-TEST
Switch Only SPBB-U1-Q
Pilot Light Only SPLNS-RE-B
Lamp, 18 W, 6 Vdc 59620527074
Lamp, 28 W, 6 Vdc 59620527075
Lamp, 18 W, 12 Vdc 59620527076
Lamp, 28 W, 12 Vdc 59620527078

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1331


© September 2010
ELS Series Emergency Lighting System Weights and Dimensions
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Weight lbs/kg Catalog Number Weight lbs/kgs Catalog Number


52.0/23.6 ELS06, ELS012 7.6/3.4 AAU1N-186
11.0/5.0 AP1050-186-DM 0.4/0.2 AAGU1
9.0/4.1 AP1050-186 5.0/2.3 AEXR-15R
12.5/5.7 AC1050-186 5.0/2.3 CJEXRN
16.6/7.5 ALB1050-186 2.1/1.0 AARW15AN
12.5/5.7 ASB1050-186 2.1/1.0 AARW15ST
4.0/1.8 EFDCB150J1U1-T-A

Dimensions in Inches/Millimeters
14.69"/
14.38"/365.3 mm 13.50"/342.9 mm 373.1 mm .38"/9.7 mm

11.63"/ 1.31"/
33.8 mm
Lighting

295.4 mm

10.75"/ 12.00"/ 14.12"/


273.1 mm 12.25"/ 358.6 mm 12.25"/
304.8 mm 311.2 mm
311.2 mm

13.13"/333.5 mm 7.06"/
179.3 mm
Lighting: Explosionproof — Emergency

Battery Enclosure Direct Mount fixture Pendant Mount


4.75"/120.7 mm 2.63"/66.8 mm
5.38"/ 2.69"/68.3 mm
136.7 mm
13.13"/
333.5 mm 12.94"/
328.7 mm
.38"/9.7 mm
3.38"/
85.9 mm
45° 13.75"/ 13.56"/
349.3 mm 344.4 mm
13.13"/
333.5 mm

13.75"/ 9.13"/
349.3 mm 231.9 mm
12.38"/
314.5 mm
7.06"/
179.3 mm

Ceiling Mount Long Bracket Mount Short Bracket Mount


3.00"/
76.2 mm
6.88"/
174.8 mm

7.63"/
5.41"/ 11.75"/298.5 mm 193.8 mm
137.4 mm
"/
.00 m
8.50"/ 104.0 m
215.9 mm 25

EFDCB150J1JU1-T-A AEXR-15R AARW15AN


33.50"/850.9 mm 13.00"/330.2 mm

9.25"/
235.0 mm

4.38"/
111.3 mm

28.67"/
728.2 mm 12.00"/ 14.00"/355.6 mm
304.8 mm

ELS with 2 direct mounted fixtures CJEXRN AARW15ST

1332 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
HBE Series Round Bulkhead Luminaires
Increased Safety

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IEC
IP65

Applications
• Suitable for use in:
— Stairways
— Small areas
— Emergency exit
Features
• For incandescent lamps 60 W to 150 W maximum, mixed lamp
100 W maximum. Lamps not supplied.
• E27 lampholder.
• Screw locking mechanism.
• Operates in all positions.
• Connection to lampholder via two 0.003 x 0.004 in2 /
2 x 2.5 mm2 terminals.
• Internal earth two terminals 0.003 x 0.004 in2 / 2 x 2.5 mm2.
External earth 0.002 x 0.006 in2 / 1 x 4 mm2.
• Three M20 entries in “T” formation. Supplied with one M20
cable gland (dia. 0.26 to 0.57 in / 6.5 to 14.5 mm) and two M20
blanking plugs.
Standard Materials HBERI15 and HBEPGZ
• Body: gray painted aluminum alloy
• Diffuser: glass
• Sealing gasket: silicone
• Guard: zinc plated steel
• Cable gland and blanking plug: polyamide
Certifications and Compliances
• Certification Type HBe150

Lighting
• Gas, Zones 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081 II 2 G
— ATEX/IEC Protection: Ex e II
— T Rating: See Table
• Dust, Zones 21 and 22
— Conforming to ATEX 94/9/CE: CE 0081 II2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: T216 °F/T102 °C to T279 °F/T137 °C

Lighting: Increased Safety/Flameproof — Bulkhead


• Ambient Temperature: -40 °F/-40 °C to 122 °F/+50 °C
• CE Declaration of Conformity: 50244
• ATEX Certificate: LCIE 02 ATEX 6228X
• IEC Certificate: LCIE Ex 02.023X
• Index of Protection (solid & liquid): IP65
• Ex Standards: EN / IEC 60079-0; 60079-7; 61241-0; 61241-1
• Product Standards: EN / IEC 60598-1
• Other Standards: EN / IEC 60529 (IP)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1333


© September 2010
HBE Series Round Bulkhead Luminaires
Increased Safety

Zone 1 & 2 - 21 & 22


II 2 GD
ATEX / IEC
IP65

Weight Volume
(lbs/kg) (in3/dm3) Pack Catalog Number
6.61/3 915.36/15 1 HBERI15

Accessories
Pack Catalog Number
Protective Guard 1 HBEPGZ

Spare lampglass 1 HBEGD

T-Rating for Dust and Gas


Power and Type Dust Gas
For Ta = 104° F/40° C 122° F/50° C
Operating Surface T° for T° at T° at
Watts Type Positions Ta = 122° F/50° C T Rating Cable Entry T Rating Cable Entry

Any Position T2  T2 

60 Incandescent 216°F/102°C T3  T3 
Lighting

T4  T4 

Any Position T2  T2 

75 Incandescent 225°F/107°C T3  T3 
Lighting: Increased Safety/Flameproof — Bulkhead

T4  T4 

Any Position T2  T2 181°F/83°C

100 Mercury 243°F/117°C T3  T3 181°F/83°C

T3  T3 

Any Position T1 194°F/90°C T1 212°F/100°C

100 Incandescent 279°F/137°C T3 194°F/90°C T2 212°F/100°C

T3  T3 

Any Position T2 180°F/82°C T2 92°C

150 Mixed 266°F/130°C T3 180°F/82°C T3 92°C

T3  T3 

 Not Applicable, no need for high temperature cable for cable entry temperature less than +176 ºF/+80 ºC

1334 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
HBE Series Round Bulkhead Luminaires
Increased Safety

Dimensions in Inches/Millimeters

6.81"/
Cable entries 173 mm
6.14"/
156 mm

Ø0.23"/
6 mm

296 mm
11.65"/
6.30"/
160 mm
Protective guard

Photometric Data ➊

Lighting
150 W Incandescent
NF C 71-120: .062 J + 0.10 T
Candela
Distribution

100°
0 94
Degrees

90°
5 95
80°
10 97
70°

Lighting: Increased Safety/Flameproof — Bulkhead


15 104
60°
20 104
30 105 50°

40 86
40°
50 85
60 77
70 113
30°
80 115
90 108
100 32 0° 15° 20°

➊ Polar curves for a 1000 lm flux, according to NF C 71-120 Luminaire symbol according to NF C 71-121.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1335


© September 2010
HBD Series Bulkhead Luminaires
Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08

Applications
• Suitable for use in:
— Stairways
— Small areas
— Emergency exit
Features
• HBDR
— Lamps (not supplied)
— Incandescent 200 W maximum
— Compact Fluorescent 23 W maximum
— Mixed 160 W maximum
— Threaded flameproof joint.
— Operates on ceiling and wall.
• HBRO
— Incandescent 60 W to 100 W maximum
— Compact fl uorescent 15 W maximum
— Operates in any position.
— For incandescent 60 W & 100 W a high temperature cable
223 °F/106 °C is required.
• Lamps are not supplied.
• E27 lampholder. HBDR
• Fixing by two integrated brackets. Round Bulkhead
• Connection to lampholder via two terminals 0.004 in2 / 2.5 mm2.
• Internal earth two terminals 0.004 in2 / 2.5 mm2.
• External earth one 0.006 in2 / 4 mm2.
• 3 x M20 threaded entries in “T” formation.
• Supplied with two blanking plugs M20.
Lighting

Standard Materials
• Body and bezel: gray painted aluminum
• Glass: sealed toughened lamp glass
• Protective guard: zinc plated steel
Certifications and Compliances
• HBRD
— Certification Type HBRd
Lighting: Increased Safety/Flameproof — Bulkhead

— Gas, Zones 1 and 2


– Conforming to ATEX 94/9/CE: CE 0081 II 2 G
– ATEX/IEC Protection: Ex d IIC
– T Rating: See Table
— Dust, Zones 21 and 22
– Conforming to ATEX 94/9/CE: CE 0081 II 2 D
– ATEX/IEC Protection: Ex tD A21
— Ambient Temperature: -40 °F/-40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50242 HBDO
— ATEX Certificate: LCIE 02 ATEX 6163 Oval Bulkhead
— IEC Certificate: LCIE Ex 02.014
• HBRO
— Certification Type HBOd
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081 II 2 G
– ATEX/IEC Protection: Ex d IIB
– T Rating: See Table
— Dust, Zones 21 and 22 • Other Certifications: GOST
– Conforming to ATEX 94/9/CE: CE 0081 II 2 D • Index of Protection (solid & liquid): IP66
– ATEX/IEC Protection: Ex tD A21 • Impact Resistance (shock): IK08
— Ambient Temperature: -4 °F/-20 °C to 104 °F/40 °C • Internal Volume: > 122.05 in3/ 2 dm3 (2 liters)
— CE Declaration of Conformity: 50232 • Ex Standards: EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
— ATEX Certificate: LCIE 02 ATEX 6162 • Product Standards: EN / IEC 60598-1
— IEC Certificate: LCIE Ex 02.013 • Other Standards: EN / IEC 60529 (IP); 62262 (IK)

1336 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
HBDR Series Bulkhead Luminaires
Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08

Weight Volume
Pack Catalog Number
(lbs/kg) (in3/dm3)

16.53/7.5 51.59/23.4 1 HBDR

Accessories
Pack Catalog Number
Protective Guard 1 HBDRPGZ

T-Rating for Gas

Operating Positions
Power and Type Ceiling Wall
Ambient
Watts Type Temperature 104° F/40° C 122° F/50° C 131°F/55°C 104° F/40° C 122° F/50° C 131°F/55°C
8 Compact Fluorescent T Rating T6 T6 T6 T6 T6 T6
15 Compact Fluorescent T Rating T6 T6 T6 T6 T6 T6
23 Compact Fluorescent T Rating T6 T6 T6 T5 T5 T4

Lighting
100 Incandescent T Rating T5 T4 T4 T5 T4 T4
T Rating T4 T4 T4 T4 T4 T4
200 Incandescent
T° at cable entry — 183° F/84° C 192° F/89° C — 183° F/84° C 192° F/89° C
100 Mixed T Rating T4 T4 T4 T4 T4 T4
T Rating T3 T3 T3 T3 T3 T3
180 Mixed
T° at cable entry — 188° F/87 C 198° F/92° C — 189° F/87° C 198° F/92° C

Lighting: Increased Safety/Flameproof — Bulkhead


Surface Temperature for Dust
Operating Positions
Power and Type Ceiling Wall
Surface T° T° at Cable Entry Surface T° T° at Cable Entry
Watts Type for Ta = 131°F/55°C Ta= 131°F/55°C for Ta = 131°F/55°C Ta= 131°F/55°C
8 Compact Fluorescent 140° F/60° C – 158° F/70° C –
15 Compact Fluorescent 147° F/64° C – 169° F/76° C –
23 Compact Fluorescent 156° F/69° C – 205° F/96° C –
100 Incandescent 221° F/105° C – 221° F/105° C –
200 Incandescent 266° F/130° C 192° F/89° C 266° F/130° C 192° F/89° C
100 Mixed 266° F/130° C – 266° F/130° C –
160 Mixed 300° F/149° C 198° F/92° C 300° F/149° C 198° F/92° C

No need for high temperature cable for cable entry temperature less than 176° F/80° C.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1337


© September 2010
HBDO Series Bulkhead Luminaires
Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08

Weight Volume
Pack Catalog Number
(lbs/kg) (in3/dm3)

6.61/3 19.84/9 1 HBDO

Accessories
Pack Catalog Number
Protective Guard 1 HBDOPGZ
Terminal block for through wiring 0.003 x 0.004 in / 2 x 2.5 mm with high
2 2
094784
temperature sleeve

T-Rating for Gas

Power and Type


Watts Type Temperature class for Ta = 104° F/40° C T° at Cable Input for Ta = 104° F/40° C
7 Compact Fluorescent T6 —
Lighting

11 Compact Fluorescent T6 —
15 Compact Fluorescent T6 —
60 Incandescent T4 223° F/106°C
100 Incandescent T4 223° F/106°C
Lighting: Increased Safety/Flameproof — Bulkhead

T-Rating for Dust

Power and Type


Watts Type Temperature class for Ta = 104° F/40° C T° at Cable Input for Ta = 104° F/40° C
7 Compact Fluorescent 169° F/76° C —
11 Compact Fluorescent 169° F/76° C —
15 Compact Fluorescent 169° F/76° C —
60 Incandescent 246° F/119° C 223° F/106° C
100 Incandescent 246° F/119° C 223° F/106° C

No need for high temperature cable for cable entry temperature less than +176 °C/+80 °C.

1338 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
HBDR Series Bulkhead Luminaire Dimensions and Photometric Data
Flameproof

Dimensions in Inches/Millimeters

7.56"/
192 mm
(with guard)

330 mm
12.99"/
Ø0.43"/
11 mm

155 mm
6.10"/
0.51"/
13 mm

6.69"/ 12.08"/
170 mm
(without guard) 307 mm

Photometric Data ➊

Lighting
Incandescent
NF C 71-120: .068 G + 0.01 T
Candela
Distribution

Degrees
100°
0 185
90°
5 178
80°
10 171

Lighting: Increased Safety/Flameproof — Bulkhead


70°
15 156
60°
20 132
25 110 50°

30 97
40°
35 87
40 90
45 100
30°
50 96
60 58
70 58 0° 10° 20°

➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1339


© September 2010
HBDO Series Bulkhead Luminaire Dimensions and Photometric Data
Flameproof

Dimensions in Inches/Millimeters

4.80"/ 7.09"/
122 mm 180 mm

220 mm
8.66"/
0.18"/
4.5 mm

6.30"/
160 mm

Photometric Data ➊

Incandescent
NF C 71-120: .068 H
Candela
Lighting

Distribution

0
Degrees 67 100°

5 94 90°
80°
10 96
70°
15 99
20 99 60°
Lighting: Increased Safety/Flameproof — Bulkhead

25 97 50°
30 95
40°
35 96
40 91
45 91 30°
50 98
60 87
0° 10° 20°
70 69

➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.

1340 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
HBN Series Round Bulkhead Luminaires
Flameproof

Zone 2 and 22
II 3 GD
ATEX / IEC
IP65

Applications
• Suitable for use in:
— Stairways
— Small areas
— Emergency exit
Features
• For incandescent lamps 60 W to 150 W maximum, mixed lamp
100 W maximum, mercury 80 W maximum (remote mercury
ballast not supplied). Lamps not supplied.
• E27 lampholder.
• Screw locking mechanism.
• Operates in all positions.
• Connection to lampholder via two 0.003 x 0.004 in2 /
2 x 2.5 mm2 terminals.
• Internal earth two terminals 0.003 x 0.004 in2 / 2 x 2.5 mm2.
External earth 0.002 x 0.006 in2 / 1 x 4 mm2.
• Three M20 entries in “T” formation. Supplied with one M20
cable gland (dia. 0.26 to 0.57 in / 6.5 to 14.5 mm) and two M20
blanking plugs.
HBNRI15 and HBEPGZ
Standard Materials
• Body: gray painted aluminum alloy
• Diffuser: glass
• Sealing gasket: silicone
• Guard: zinc plated steel
• Cable gland and blanking plug: polyamide
Certifications and Compliances

Lighting
• Certification Type HBn150
• Gas, Zone 2
— Conforming to ATEX 94/9/CE: CE II 3 G
— ATEX/IEC Protection: Ex nR II
— T Rating: See Table 1
• Dust, Zone 22
— Conforming to ATEX 94/9/CE: CE II 3 D
— ATEX/IEC Protection: Ex tD A22

Lighting: Increased Safety/Flameproof — Bulkhead


— Surface Temperature: See Table 1
• Ambient Temperature: -4 °F/-20°C Ta 122°F/50°C
-4 °F/-20°C Ta 104 °F/40°C (80 W mercury)
• CE Declaration of Conformity: 50220
• ATEX Certificate: LCIE 03 ATEX 6167X
• IEC Certificate: LCIE Ex 03.026X
• Index of Protection (solid & liquid): IP65
• Ex Standards: EN / IEC 60079-0; 60079-15; 61241-0; 61241-1
• Product Standards: EN / IEC 60598-1
• EMC Standards: EN / IEC 55015; 61547
• Other Standards: EN / IEC 60529 (IP)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1341


© September 2010
HBN Series Round Bulkhead Luminaires
Flameproof

Zone 2 and 22
II 3 GD
ATEX / IEC
IP65

Weight Volume
Pack Catalog Number
(lbs/kg) (in3/dm3)

6.61/3 33.07/15 1 HBNRI15

Accessories
Pack Catalog Number
Protective Guard 1 HBEPGZ
Spare Lampglass HBEGD

T-Rating for Dust and Gas

Dust Gas
Power and Type
Surface T° for T Rating for T Rating for
Watts Type Ta = 122 °F/+50 °C Ta = 104 °F/+40 °C Ta = 122 °F/+50 °C T° at Cable Input
Lighting

60 Incandescent 214 °F/101 °C T5 T4 —

75 Incandescent 219 °F/104 °C T5 T4 —

268 °F/131 °C
80 Mercury T3 — —
(Ta = 104 °F/+40 °C)

100 Incandescent 237 °F/114 °C T4 T4 181 °F/83 °C


Lighting: Increased Safety/Flameproof — Bulkhead

100 Mixed 257 °F/125 °C T4 T4 212 °F/100 °C

150 Incandescent 248 °F/120 °C T4 T4 198 °F/92 °C

1342 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
HBN Series Round Bulkhead Luminaire Dimensions and Photometric Data
Flameproof

Dimensions in Inches/Millimeters

Cable Entries
Cable entries 6.81"/173 mm
6.14"/
156 mm

11.65"/296 mm
0.24"/
6 mm

6.30"/
160 mm Protectiveguard
Protective Guard

Photometric Data ➊

Incandescent
NF C 71-120: .062 J + 0.10 T
Candela

Lighting
Distribution

100°
0
Degrees
185
90°
5 178
80°
10 171
70°
15 156
60°
20 132
30 110 50°

Lighting: Increased Safety/Flameproof — Bulkhead


40 97
40°
50 87
60 90
70 100
30°
80 96
90 58
100 58 0° 10° 20°

➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1343


© September 2010
HBDC Series Cylindrical Bulkhead Luminaires
Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08

Applications
• For illumination of:
— Stairways
— Small areas
— Emergency exit
Features
• For lamps:
— 70 W high pressure sodium (ovoid type E27 lampholder)
— 18/20 W compact fluorescent lamp (E27 lampholder) 70 W Sodium Version
— 2 x 40 W incandescent lamp (E27 lampholder)
— 8 W fluorescent bulb (G5 lampholder) (lamp supplied)
• HPS version: compensated power supply 230/240 V 50 Hz
(+/-10%) with power factor 0.9.
• Connection to plug-in terminal block via 2 x 3 terminals
.025 cm²/2.5 mm².
• Operates in any position.
• Threaded access cover with O-ring seal.
• Two integrated mounting lugs.
• 1 external earth via .04 cm²/4 mm² bracket. Compact Fluorescent Version
• 2 threaded cable entries.
• Supplied with 1 plug M20 (cable gland not supplied).
Standard Material
• End cap and cover: Zamak, anticorrosion treated and
painted gray
• Sealed tube: toughened glass
• External reflector: galvanized steel painted white
Lighting

• Protective guard: zinc plated steel


• Lamps are not supplied except for 8 W fluorescent bulb
Options
• Fixing accessories available in 316 stainless steel
or zinc plated steel.
• Fall prevention fixing kit in stainless steel.
Certifications and Compliances
Lighting: Increased Safety/Flameproof — Bulkhead

• Certification Type: FLd


• Zone 1 - 2
— Conforming to ATEX 94/9/CE: CE 0081 II 2 G
— ATEX/IEC Protection: Ex d IIC
— T Rating: See Table
• Zone 21 - 22
— Conforming to ATEX 94/9/CE: CE 0081 II 2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: (See table)
• Ambient Temperature: -4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C
-4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C for 70W HPS
• CE Declaration of Conformity: 50203
• ATEX Certificate: LCIE 97/ ATEX 6012
• IECEx Certificate: IECEx LCI 04.0018
• Other Certifications: GOST
• Index of Protection (solid & liquid): IP66 / 68 (10 m)
• Impact Resistance (shock): IK08
• Internal Volume: > 122 in³/2 dm3 (2 liters)
• Ex Standards EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
• Product Standards: EN / IEC 60598-1
• Other Standards: EN / IEC 60529 (IP); 62262 (IK)

1344 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
HBDC Series Cylindrical Bulkhead Luminaires
Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
HBDC F 1 40 02A

Series: Quantity of Lamps: Voltage:


HBDC 1 - One Lamp 02A - 24 Vac 50/60 Hz
2 - Two Lamp 02D - 24 Vdc
04A - 48 Vac 50/60 Hz
04D - 48 Vdc
11A - 110 Vac 50/60 Hz
11D - 110 Vdc
24A - 230/240 Vac 50/60 Hz ➍
24B - 230/240 Vac/Vdc 50/60 Hz

Lamp Type: Power:


I - Incandescent 40 - 40 W ➊
F - Fluorescent 18 - 18/20 W ➋
L - High Pressure Sodium 70 - 70 W ➌
08 - 8 W Fluorescent

Weight Volume Catalog


Lamp Lampholder Voltage lbs/kgs in3/dm3 Number Pack
2x40 W Incandescent ➎ E27 – 16/7.1 1892/31 HBDCI240 1

Lighting
70 W HP Sodium ➎ E27 230/240 Vac 50 Hz 16/7.1 2014/33 HBDCL17024A 1
1x8 W Fluorescent G5 24 Vdc 18/8.3 1892/31 HBDCF10802D 1
1x8 W Fluorescent G5 48 Vdc 18/8.3 1892/31 HBDCF10804D 1
1x8 W Fluorescent G5 110 Vdc 18/8.3 1892/31 HBDCF10811D 1
G5 230/240 Vac 50/60 Hz 18/8.3 1892/31 HBDCF10824B 1
1x8 W Fluorescent
198/254 Vdc

Lighting: Increased Safety/Flameproof — Bulkhead


G5 230/240 Vac 50/60 Hz 18/8.3 1892/31 HBDCF20824B 1
2x8 W Fluorescent
198/254 Vdc
1x18/20 W Compact Fluorescent (1) E27 – 16/7.1 2014/33 HBDCF118 1

Dust Gas
Surface Temperature T Rating
Without With
External Reflector External Reflector
Without With
External Reflector External Reflector Ta=+104 °F/ Ta=+131 °F/ Ta=+104 °F/ Ta=+131°F/
Versions °F/°C °F/°C +40 °C +55 °C +40°C +55°C
Incandescent lamp (2x40 W) 203/95 203/95 T5 T5 T5 T5
Compact Fluorescent lamp (20 W max) 203/95 266/130 T6 T5 T5 T4
Fluorescent (8 W - G5 lampholder) 203/95 266/130 T6 T5 T5 T4
T4 for Ta = +122 °F/
High Pressure Sodium Lamp (70 W ovoid) 252/122 – – –
+50°C
➊ Incandescent Lamp
➋ Compact Fluorescent Lamp
➌ High Pressure Sodium Lamp (HP)
➍ 50 Hz only for the 70 W HPS Version
➎ Lamp not supplied

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1345


© September 2010
HBDC Series Cylindrical Bulkhead Luminaires
Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08

Accessories
Description Catalog Number Packing
External reflector in galvanized steel (painted white) FDER1G 1
(not compatible with 70 W HPS version)

Protective guard in zinc plated steel FDPG1Z 1


Protective guard in zinc plated steel for 70 W HPS version FDPG5Z 1
Quick one-hand fixing (Set of 2 brackets) in zinc plated steel FDFBZ 1
Quick one-hand fixing (Set of 2 brackets) in 316 stainless steel FDFBS 1

Fixing unit on flat surface (Set of 2 brackets) in zinc plated steel FDSBZ 1
Fixing unit on flat surface (Set of 2 brackets) in 316 stainless steel FDSBS 1

Fixing unit for 1"1/2 (Ø1.93"/49 mm) or 1"1/4 (Ø1.65"/42 mm) tube 1
in zinc plated steel FDHC49Z
Fixing unit for 1"1/2 (Ø1.93"/49 mm) or 1"1/4 (Ø1.65"/42 mm) tube 1
in 316 stainless steel FDHC49S
Fixing unit for 2" (Ø2.36"/60 mm) tube in zinc plated steel FDHC60Z 1
Fixing unit for 2" (Ø2.36"/60 mm) tube in 316 stainless steel FDHC60S 1
Fall prevention fixing kit (.05"/1.2 m chain) in stainless steel FDSCS 1

Dimensions (In/mm)
Lighting

HBDCL17024A (70 W HP Sodium) HBDC and HBDCF


14.76"/ 3.05"/ 13.19"/ 3.05"/
375 mm 77.5
77.5 mm 335 mm 77.5 mm
77.5
5.91"/ 0.47"/ 5.91"/ 0.47"/ 0.98"/
150 mm 12 mm
0.98"/
25 mm
0.43"/
11 mm
150 mm 12 mm 25 mm
0.43"/
11 mm

Ø0.47"/ Ø0.47"/
12 mm 12 mm
0.20"/
7.52"/191 mm

7.52"/191 mm

0.20"/
5.0 mm
0.59"/ 0.59"/ 5.0 mm
15 mm 15.75"/ 15 mm 15.75"/
400 mm
400 mm 400 mm
400 mm
mini mini
Lighting: Increased Safety/Flameproof — Bulkhead

18.50"/ 16.92"/
470 mm 430 mm
3.50"/ 3.35"/ 3.50"/ 3.35"/
89 mm 85 mm 89 mm 85 mm

Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120 Longitudinal
Luminaire symbol according to NF C 71-121 Transverse

70 W HP Sodium 2x40 W Incandescent


Efficiency 59.4% Efficiency: 75.6%
NF C 71-121: 0.56G + 0.04T NFC 71-121: 0.74G + 0.02T
Candela Distribution Candela Distribution
0-180 90-270 0-180 90-270
0 166 166 0 196 Degrees 196
5 167 165 150° 120° 5 197 198 100°
105° 90°
10 164 Degrees162 10 196 196 80°
15 162 156 90° 15 193 194 70°
20 158 151 75° 20 189 190 60°
25 155 143 60° 25 181 185 50°
30 151 133 30 176 179
45° 40°
35 146 122 35 170 172
40 141 110 40 163 164
45 135 95 45 155 153 30°
50 128 81 30° 50 145 128
0° 10° 20°
55 120 66 60 123 91
60 111 52 0° 15° 70 99 43
65 101 39
70 90 27

1346 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V; 300 W-500 W Incandescent.

Applications
• For illumination of manufacturing, storage, and other indoor
areas.
Features
• Standard Baymaster fixtures operate in high ambient
temperatures. All units suitable for minimum 194 °F/90 °C
supply wire.
• High efficiency (up to 78% with 250 W HPS lamps) with
exceptionally long lamp life—economical to own and operate.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Sockets are heavy duty mogul base, with spring loaded, nickel
plated center contact and heavy gauge, nickel plated brass
screw shell with double lamp grips to prevent lamps from

Lighting: General Lighting — Area — High Bay


loosening due to vibration.
• Efficient, low glare, compact reflector.
• Reflector installs and adjusts to wide, medium, or narrow
distribution (without tools) by repositioning spring locks.
• Installation is quick and easy: Complete Fixture
(1) mount junction box to 0.75”/33.4 mm conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp
(5) snap reflector in place.
• Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.
Standard Materials
• Ballast: finned, copperfree (4/10 of 1% max.) aluminum
• Reflector: aluminum Ballast Housing Assembly
• Sockets: porcelain
• Locks: stainless steel
Dimensions
Standard Finishes
• Ballast: white powder coat polyester
• Reflector: natural finished 12.38"/
314.5 mm
Options

Lighting
• All units available with a sensor circuit for automatically
lighting an auxiliary safety lamp if a power dip or lamp failure 13.75"/349.3 mm
extinguishes the HID lamp.
Certifications and Compliances
• UL Listed: E109438 6.25"/
• UL Standard: 1598 158.8 mm
• CSA Certified: LR9349
4.75"/349.3 mm

Related Products 5.5"/139.7 mm


• For power hook, fusing and other suspension accessories, see 15.88"/
Fixture Hanger Accessories page. 403.4 mm Min.
18.25"/
463.6 mm Max

10.38"/
263.7 mm

16"/
406.4 mm

Remote Ballast Mounting


V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1347


© September 2010
Baymaster 250/400™ High Bay Luminaire Performance
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

High Pressure Sodium


• 149 °F/65 °C maximum ambient temperature for 150 W-250 W
• 131 °F/55 °C maximum ambient temperature 400 W
150 Watt 175 Watt 250 Watt 400 Watt
Distribution * Effic. S./M.H. † Effic. S./M.H. † Effic. S./M.H. † Effic. S./M.H. †
Narrow 71.0% .8:1 — — 80.0% 0.6:1 80.0% 0.6:1

Medium 72.1% 1.5:1 — — 77.5% 1.4:1 77.6% 1.4:1

Wide 73.2% 2.5:1 — — 74.6% 2.5:1 75.4% 2.5:1

Pulse Start Metal Halide


• 149 °F/65 °C maximum ambient temperature for 175 W-250 W
Lighting: General Lighting — Area — High Bay

• 131 °F/55 °C maximum ambient temperature 320 W-450 W


175 Watt 200 Watt 250 Watt 320 Watt 400 Watt 450 Watt
Distribution * Effic. S./M.H. † Effic. S./M.H. † Effic. S./M.H. † Effic. S./M.H. † Effic. S./M.H. † Effic. S./M.H. †
Narrow 67.7% 0.6:1 73.3% 0.7:1 78.6% 0.2:1 67.5% 0.7:1 67.5% 0.7:1 67.2% 0.7:1

Medium 72.3% 1.4:1 73.8% 1.7:1 75.2% 1.5:1 70.3% 1.6:1 70.6% 1.6:1 70.7% 1.4:1

Wide 74.6% 2.0:1 72.8% 2.2:1 74.1% 2.1:1 70.6% 2.1:1 71.4% 2.1:1 71.6% 2.0:1

Metal Halide V
• 149 °F/65 °C maximum ambient temperature for 175 W-250 W
• 131 °F/55 °C maximum ambient temperature 400 W

175 Watt 250 Watt 400 Watt


Distribution * Effic. S./M.H. † Effic. S./M.H. † Effic. S./M.H. †
Narrow 82.9% 0.8:1 82.9% 0.8:1 79.6% 1:1

Medium 82.8% 1.8:1 82.8% 1.8:1 77.2% 2:1


Lighting

Wide 80.4% 2.4:1 80.4% 2.4:1 75.2% 2.7:1

V CSA Certification only.

1348 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster 250/400™ High Bay Luminaire Electrical Specifications
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
150 W 250 W 400 W
Line Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 2.00 1.70 188 2.00 2.50 295 3.30 3.80 465
208 1.15 .95 188 1.20 1.50 295 1.80 2.20 465
240 1.00 .85 188 1.00 1.30 295 1.60 1.90 465
277 .85 .72 188 .85 1.10 295 1.40 1.70 465
347 V 0.52 0.56 188 0.60 0.93 295 1.00 1.32 465
480 .50 .47 189 .40 .65 295 .80 1.00 465

Lighting: General Lighting — Area — High Bay


Pulse Start Metal Halide — Super C.W.A. Ballast Amps
175 W 200 W 250 W 320 W 400 W 450 W
Line Total Total Total Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 .90 1.78 199 2.10 2.00 235 1.90 2.50 288 2.60 3.25 368 3.50 4.00 454 4.00 4.40 510
208 .50 1.08 199 1.15 1.25 235 1.10 1.45 288 1.50 1.90 368 2.00 2.30 454 2.30 2.60 510
240 .35 .89 199 1.10 1.00 235 .96 1.25 288 1.30 1.65 368 1.75 2.00 454 2.00 2.20 510
277 .30 .76 199 .75 .85 235 .85 1.10 288 1.15 1.40 368 1.50 1.75 454 1.70 1.90 510
347 V 0.25 0.65 199 .25 .70 232 0.62 0.90 288 0.70 1.10 368 1.10 1.35 454 1.10 1.50 505
480 .25 .50 213 .35 .50 237 .46 .60 285 .60 .80 368 .90 1.00 454 .85 1.12 514

Metal Halide V — C.W.A. Ballast Amps


175 W 250 W 400 W
Line Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 1.3 1.8 213 1.2 2.6 295 3.25 4.0 458

Lighting
208 .75 1.1 213 .65 1.5 295 1.9 2.3 458
240 .65 .90 213 .60 1.3 295 1.65 2.0 458
277 .55 .78 213 .50 1.12 295 1.4 1.75 458
347 0.50 0.65 213 0.80 0.90 295 1.20 1.40 458

V CSA Certified only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1349


© September 2010
Baymaster 250/400™ High Bay Luminaires
Quick Estimate Illumination Charts *
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

400 Watt High Pressure Sodium 400 Watt Pulse Start Metal Halide

250 Watt High Pressure Sodium 250 Watt Pulse Start Metal Halide
Lighting: General Lighting — Area — High Bay

How to use Quick-Estimate Illumination Chart


1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft./232.2 Sq.M. thru
10,000 Sq. Ft./929.0 Sq. M. A “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated)
to right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
Lighting

5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.

* Photometric charts available on request.


V CSA Certification only.

1350 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

Pendant Mounting (3/4”)

Catalog Number
Lamp Type Voltage Complete Assembly ➊➋ Ballast Housing Assembly
For High Pressure Sodium Lamps
150 W HPS 120/208/240/277 V G-HB41AL-MT G-HB411L-MT
150 W HPS 120/277/347 V G-HB41AL-TT V➌ G-HB411L-TT V➌
150 W HPS 480 V G-HB41AL-48 G-HB411L-48
250 W HPS 120/208/240/277 V G-HB61AL-MT G-HB611L-MT
250 W HPS 120/277/347 V G-HB61AL-TT V➌ G-HB611L-TT V➌
250 W HPS 480 V G-HB61AL-48 G-HB611L-48
400 W HPS 120/208/240/277 V G-HB71AL-MT G-HB711L-MT

Lighting: General Lighting — Area — High Bay


400 W HPS 120/277/347 V G-HB71AL-TT V➌ G-HB711L-TT V➌
400 W HPS 480 V G-HB71AL-48 G-HB711L-48
For Pulse Start Metal Halide Lamps
175 W PSMH 120/208/240/277 V G-HB51AP-MT G-HB511P-MT
175 W PSMH 120/277/347 V G-HB51AP-TT V➌ G-HB511P-TT V➌
175 W PSMH 480 V G-HB51AP-48 G-HB511P-48
200 W PSMH 120/208/240/277 V G-HB201AP-MT G-HB2011P-MT
200 W PSMH 120/277/347 V G-HB201AP-TT V➌ G-HB2011P-TT V➌
200 W PSMH 480 V G-HB201AP-48 G-HB2011P-48
250 W PSMH 120/208/240/277 V G-HB61AP-MT G-HB611P-MT
250 W PSMH 120/277/347 V G-HB61AP-TT V➌ G-HB611P-TT V➌
250 W PSMH 480 V G-HB61AP-48 G-HB611P-48
320 W PSMH 120/208/240/277 V G-HB321AP-MT G-HB3211P-MT
320 W PSMH 120/277/347 V G-HB321AP-TT V➌ G-HB3211P-TT V➌
320 W PSMH 480 V G-HB321AP-48 G-HB3211P-48
400 W PSMH 120/208/240/277 V G-HB71AP-MT G-HB711P-MT
400 W PSMH 120/277/347 V G-HB71AP-TT V➌ G-HB711P-TT V➌

Lighting
400 W PSMH 480 V G-HB71AP-48 G-HB711P-48
450 W PSMH 120/208/240/277 V G-HB451AP-MT G-HB4511P-MT
450 W PSMH 120/277/347 V G-HB451AP-TT V➌ G-HB4511P-TT V➌
450 W PSMH 480 V G-HB451AP-48 G-HB4511P-48
For Metal Halide Lamps V
175 W MH 120/208/240/277 V G-HB51AH-MT V G-HB511H-MT V
175 W MH 120/277/347 V G-HB51AH-TT V➌ G-HB511H-TT V➌
250 W MH 120/208/240/277 V G-HB61AH-MT V G-HB611H-MT V
250 W MH 120/277/347 V G-HB61AH-TT V➌ G-HB611H-TT V➌
400 W MH 120/208/240/277 V G-HB71AH-MT V G-HB711H-MT V
400 W MH 120/277/347 V G-HB71AH-TT V➌ G-HB711H-TT V➌

➊ Add suffix -E to catalog number if provision for 250 W quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired
(not available on units for remote ballast).
➋ To order fixture complete with lamp, add suffix -L to catalog number.
➌ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1351


© September 2010
Baymaster 250/400™ High Bay Luminaire Accessories and Replacement Parts
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V; 300 W-500 W Incandescent.

For Incandescent Lamps or HID lamps and Remote Ballast ➊


Lamp Type Voltage Catalog Number➑
For Incandescent Lamps or HID lamps and Remote Ballast ➊
300 W-500 W PS-35, incandescent G-H71AM-RB
250 W-400 W, HPS G-H71AL-RB
250 W, PSMH/MH G-H71AM-RB
400 W, PSMH/MH G-H71AM-RB
Accessories and Replacement Parts
Type Description Catalog Number
Glass Lenses ➋
With clear, thermal shock and impact G-HB7000-NL
Lighting: General Lighting — Area — High Bay

resistant glass lens.


1.0"/
25.4 mm
With prismatic Corning-73 thermal shock G-HB7000-NL3
and impact resistant lens.

16.06"/407.9 mm

Reflector
Reflector only. G-7AW

Socket Shroud
2.25"/
57.2 mm
3.0"/ Aluminum, with gasket G-HB7000-SS
76.2 mm
(closes off reflector).

2.88"/73.2 mm

6.0"/
152.4 mm

Wire Guard
Lighting

Has relamp opening, zinc plated. G-HB7000-NG

1.0"/
25.4 mm

16.75"/
425.5 mm

Safety Cable (not shown) G-HB7000-SC


Fuseholder
Has 9”/228.6 mm wire leads. G-F10

1.31"/
33.3 mm

Wiring Kit (not shown)


Supplied with 3 feet of 16/3 SOOW cable PWK V
and FHHM-75SS cast safety hook
➊ For remote ballast consult your local sales representative.
➋ Lens assemblies shown have stainless steel frame and are furnished with an aluminum socket shroud to close off reflector top (shroud shown). Can be field
installed.
V CSA Certification only.

1352 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

Applications
• For illumination of manufacturing, storage, and other indoor
areas.
Features
• Standard Baymaster fixtures operate in 104 °F/40 °C ambient
temperatures. All units suitable for minimum 194 °F/90 °C
supply wire.
• High efficiency (up to 78% with 250 W HPS lamps) with
exceptionally long lamp life—economical to own and operate.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Mogul base sockets with spring loaded center contact and
heavy guage screw shell with double lamp grips to prevent
lamps from loosening due to vibration.

Lighting: General Lighting — Area — High Bay


• Efficient, low glare, compact reflector is UV stabilized,
clear, injection molded high-temperature acrylic that provides
15-20% uplight.
• Reflector installs and adjusts to wide, medium, or narrow
distribution (without tools) by repositioning spring locks.
• Installation is quick and easy:
(1) mount junction box to 3/4”/19.1 mm conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp Dimensions
(5) snap reflector in place
• Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.
Standard Materials
• Ballast: finned, aluminum
• Sockets: heavy duty porcelain
• Reflector: acrylic 25.0"/635.0 mm
• Locks: stainless steel 26.0"/660.4 mm
Standard Finishes 27.25"/692.2 mm

• Ballast: corrosion polyester


• Sockets: nickel plated center contact

Lighting
• Screws: nickel plated brass
Options
• All units available with a sensor circuit for automatically
lighting an auxiliary safety lamp if a power dip or lamp failure 16.25"/
412.8 mm
extinguishes the HID lamp.
Certifications and Compliances
• UL Listed: E109438
• UL Standard: 1598
• CSA Certified: LR9349
Related Products
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1353


© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

Pendant Mounting
Catalog Number
Lamp Type Voltage
Complete Assembly ➊ Ballast Housing Assembly
For High Pressure Sodium Lamps
150 W HPS 120/208/240/277 V G-HB41PL-MT G-HB411L-MT
150 W HPS 120/277/347 V G-HB41PL-TT V➋ G-HB411L-TT V➋
150 W HPS 480 G-HB41PL-48 G-HB411L-48
250 W HPS 120/208/240/277 V G-HB61PL-MT G-HB611L-MT
250 W HPS 120/277/347 V G-HB61PL-TT V➋ G-HB611L-TT V➋
250 W HPS 480 G-HB61PL-48 G-HB611L-48
400 W HPS 120/208/240/277 V G-HB71PL-MT G-HB711L-MT
Lighting: General Lighting — Area — High Bay

400 W HPS 120/277/347 V G-HB71PL-TT V➋ G-HB711L-TT V➋


400 W HPS 480 G-HB71PL-48 G-HB711L-48
For Pulse Start Metal Halide Lamps
400 W PSMH 120/208/240/277 V G-HB71PP-MT G-HB711P-MT
400 W PSMH 120/277/347 V G-HB71PP-TT V➋ G-HB711P-TT V➋
400 W PSMH 480 G-HB71PP-48 G-HB711P-48
For Metal Halide Lamps V
400 W MH 120/208/240/277 V G-HB71PH-MT V G-HB711H-MT V
400 W MH 120/277/347 V G-HB71PH-TT V➋ G-HB711H-TT V➋

Accessories
Description Catalog Number

16” Prismatic Reflector only. G-7PR

16” Prismatic Reflector with clamp band and clear tempered glass lens. G-7PR-IL V
Lighting

16” Prismatic Reflector with clamp band and prismatic acrylic lens. G-7PR-ILP V

➊ To order fixture complete with lamp, add suffix -L to catalog number.


➋ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.

1354 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaire Electrical Specifications
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

• Ballast has primary taps for 120, 208, 240 and 277 Volts.
• Add suffix -E to catalog number if provision for 150 W quartz emergency lamp is desired (lamp not included). Furnished with socket
installed and pre-wired.
• 400 W MH lamps: some manufacturers recommend that their lamps be operated in enclosed units only—contact your lamp distributor or
lamp manufacturer for the latest safety information.
• To order fixture complete with lamp, add suffix -L to catalog number.

High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
150 W 250 W 400 W
Line Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 2.00 1.70 188 2.00 2.50 295 3.30 3.80 465
208 1.15 .95 188 1.20 1.50 295 1.80 2.20 465

Lighting: General Lighting — Area — High Bay


240 1.00 .85 188 1.00 1.30 295 1.60 1.90 465
277 .85 .72 188 .85 1.10 295 1.40 1.70 465
347 V 0.52 0.56 188 0.60 0.93 295 1.00 1.32 465
480 .50 .47 189 .40 .65 295 .80 1.00 465

Pulse Start Metal Halide — Super C.W.A. Ballast Amps


175 W 200 W 250 W 320 W 400 W 450 W
Line Total Total Total Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 .90 1.78 199 2.10 2.00 235 1.90 2.50 288 2.60 3.25 368 3.50 4.00 454 4.00 4.40 510
208 .50 1.08 199 1.15 1.25 235 1.10 1.45 288 1.50 1.90 368 2.00 2.30 454 2.30 2.60 510
240 .35 .89 199 1.10 1.00 235 .96 1.25 288 1.30 1.65 368 1.75 2.00 454 2.00 2.20 510
277 .30 .76 199 .75 .85 235 .85 1.10 288 1.15 1.40 368 1.50 1.75 454 1.70 1.90 510
347 V 0.25 0.65 199 .25 .70 232 0.62 0.90 288 0.70 1.10 368 1.10 1.35 454 1.10 1.50 505
480 .25 .50 213 .35 .50 237 .46 .60 285 .60 .80 368 .90 1.00 454 .85 1.12 514

Lighting
Metal Halide V — C.W.A. Ballast Amps
175 W 250 W 400 W
Line Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 1.3 1.8 213 1.2 2.6 295 3.25 4.0 458
208 .75 1.1 213 .65 1.5 295 1.9 2.3 458
240 .65 .90 213 .60 1.3 295 1.65 2.0 458
277 .55 .78 213 .50 1.12 295 1.4 1.75 458
347 0.50 0.65 213 0.80 0.90 295 1.20 1.40 458

V CSA Certified only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1355


© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaires
Quick-Estimate Illumination Charts *
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

400 Watt High Pressure Sodium 400 Watt Pulse Start Metal Halide
Lighting: General Lighting — Area — High Bay

250 Watt High Pressure Sodium 250 Watt Pulse Start Metal Halide

How to use Quick-Estimate Illumination Chart


1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft. thru 10,000 Sq. Ft. A
“Large Room” is 10,000 Sq. Ft. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated) to
right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
Lighting

4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
* Photometric charts available on request.

* Photometric charts available on request.


V CSA Certification only.

1356 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaire Photometric Data *
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

Square Steel Poles for Davit Mount Luminaires

Typical Footcandle Values


Distance (ft) Mounting Height Feet 400 Watt High Pressure Sodium
Ahead/
Behind
Footcandle 30 40 50 60
165 — — .01 .02
160 — — .01 .03

Distance in terms of mounting height ◊


155 — — .01 .03
150 — — .02 .04
145 — — .02 .04
140 — .01 .03 .06
135 — .01 .03 .09
130 — .01 .04 .14

Lighting: General Lighting — Area — High Bay


125 — .02 .05 .20
120 — .03 .06 .27
115 — .04 .10 .35
110 .01 .05 .17 .46
105 .01 .06 .26 .60
100 .02 .08 .38 .77
95 .03 .10 .54 .93
90 .05 .21 .74 1.13
85 .07 .37 1.00 1.37
80 .10 .60 1.29 1.66 Distance in terms of mounting height ◊
75 .14 .91 1.62 2.02
70 .23 1.35 2.05 2.16
65 .55 1.91 2.69 2.21
60 1.06 2.53 9.07 2.21
55 1.85 3.39 3.17 2.18 400 W HPS Ft. Candles for Iso-Footcandle Lines
50 3.08 4.55 3.19 2.34 Mtg. Ht. A B C D E F G H
45 4.51 4.93 3.16 2.24 20 29.03 20.21 19.19 8.07 2.39 .39 .17 .04
40 6.64 4.98 3.23 2.31 25 18.58 12.91 12.28 5.16 1.53 .25 .11 .04
35 8.65 4.98 3.18 2.57 30 12.90 8.98 8.53 3.59 1.06 .17 .08 .03
30 8.85 5.04 3.63 2.85 35 9.48 6.60 6.27 2.63 .78 .13 .06 .02
25 8.95 5.49 4.10 3.16 40 7.26 5.05 4.80 2.02 .60 .10 .04 .02
20 9.25 6.41 4.64 3.43 45 5.73 4.00 3.79 1.59 .47 .08 .03 .01

Lighting
15 11.4 7.47 4.95 3.41
10 13.7 7.67 4.83 3.18 This report has been prepared in accordance with IES guides on testing procedures. It is
5 12.7 6.53 3.93 2.60 representative of luminaires tested under standardized and stabilized laboratory conditions.
0 6.58 3.70 2.37 1.65 Various operating factors can cause differences between laboratory data and actual field
-5 1.15 .81 .58 .48 performance.
-10 .60 .40 .33 .29
-15 .77 .31 .23 .18
-20 1.13 .43 .21 .15
-25 1.11 .59 .26 .15
-30 .85 .70 .35 .19

◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.
* Additional photometric charts available on request.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1357


© September 2010
Super-Baymaster High Bay Luminaires V
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.

Applications
• For illumination of mills (pulp and paper), manufacturing, storage
and other areas where corrosion, moisture or dust present
severe problems.
• CSA approved weatherproof (Encl. 3) with open reflector and
dust-tight (Encl. 3 and 5) with enclosing lens.
• Will operate safely in temperatures ranging from -40 °F/-40 °C
to +149 °F/+65 °C ambient.
Features
• Corrosion resistant. All external surfaces of the ballast housing
are coated with a heavy-duty epoxy-finish providing
durability and resistant to both alkali and acidic atmospheric
conditions. To suit specific atmospheric requirements,
consult the factory for a suitable finish.
• High efficiency reflectors (up to 76% with 1000 W MH lamps)
Lighting: General Lighting — Area — High Bay

and ­exceptionally long HID lamp life make Super-­Baymaster


luminaires unusually economical to own and operate.
• The Baymaster reflector is a unique ­design that combines high
efficiency with low glare in a compact size.
• Super-Baymaster luminaires are furnished with open reflectors.
For enclosed reflectors, clear or prismatic glass are available.
• Pre-wired with high temperature fixture wire, these integral
ballasted luminaires are supplied with dual-tap primary for 120
or 240 Volt lines or with 208, 277 or 347 Volt primary. Ballasts
are highest quality, Class H insulated, CWA and CWI types, Shown with optional lens: 1000 W
­thermally isolated for cooler operating and
long life. Grounding wire provided.
• To protect the internal components of the luminaire from Dimensions
corrosive atmospheres all mating surfaces are gasketed.
• Mogul base socket with spring loaded center contact and heavy Height
gauge, screw shell with double lamp grips to prevent lamps 20-7/8"/530.4 mm; 150-400 W MV/MH
from loosening due to vibration. 19-11/16"/500.1 mm; 1000 W
• Installation is quick and easy:
(1) lift ­ballast assembly onto the hanger hub and rotate 60° until
sealed on hub Width
(2) tighten locking nut (hand tight) to secure ballast assembly 16"/406.4 mm; 150-400 W
(3) make supply connections (90° wire) and replace wiring cover 20"/508.0 mm; 1000 W
(4) snap reflector in place
(5) install lamp Height
Lighting

29"/736.6 mm; 150-400 W MV/MH


Standard Materials 31"/787.4 mm; 1000 W
• Reflector: aluminum
• Sockets: porcelain
Width
Standard Finishes 16"/406.4 mm; 150-400 W
• Screws: nickel plated brass 20"/508.0 mm; 1000 W
• Housing: epoxy powder coated external surfaces
Options
• Quartz auxiliary: units are available with a pre-wired sensor
circuit for automatically lighting a quartz auxiliary lamp when
power dip or lamp failure extinguishes the main HID lamp. Certifications and Compliances
• Fuse kits: for grounded systems. • UL Listed: E109938
• Lenses: clear or prismatic glass with heavy-duty, stainless steel • UL Standard: 1598
clips to secure lens to reflector. • CSA Certified: 009349
• HPS units available with a pulse ­eliminator which effectively • CSA Standard: C22.2 No. 250.0
shuts down the ballast assembly when lamp fails.
• Optional finishes may be ordered to suit specific environments Related Products
in regular or ­specific colors. • For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

V CSA Certification only.

1358 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Super-Baymaster High Bay Luminaires V
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide for GSB and GSS
GSB 4 1 A L C MT E

Series: Beam Spread: Lamp Type: Voltage:


GSB – Super- 1 – Narrow (not for L – High Pressure Sodium MT – 120, 208,
Baymaster 1000 W) H – Metal Halide 240, 277V
GSS – Super- 2 – Medium M – Mercury Vapour CWA
Baymaster 3 – Wide P – Pulse Start Metal Halide TT – 120, 277,
Side by Side 347V CWA
208 – 208 Volts
RB – Remote
Ballast

Wattage: Reflector: Ballast Type: Voltage:

Lighting: General Lighting — Area — High Bay


4 – 150 watt A – Complete with reflector C – CWI E – Provision for 250 W
5 – 175 watt Blank – Ballast assembly only A – CWA quartz emergency
6 – 250 watt lamp (pre-wired)
7 – 400 watt S – Provision for pulse
8 – 1000 watt eliminator
F – Fuse for grounded
systems (single
pole)
LC – Gasketed clear
lens assembly
LP – Gasketed
prismatic lens
assembly
CR – Corrosion
resistant epoxy
paint on reflector
exterior surface

Accessories and Replacement Parts

Description Catalog Number

Lighting
Wire Guard With relamp door. Zinc plated G-HB-20-G

Safety Chain Secures ballast and reflector G-HB-7000-SC

Supplied with 3 feet of 600V –194 °F/90


°C 3-conductor no. 16 SOW cable and
Wiring Kit
3/4”/19.1 mm FHHM hook (shipped PWK
­separately) Add Suffix:

Sockets
Socket for Metal Halide and Mercury Vapor SPF-1004

Socket for High Pressure Sodium SPF-1001

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1359


© September 2010
Super-Baymaster High Bay Luminaires V
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.

Luminaire Performance
150 Watt 200 Watt 250 Watt 400 Watt 1000 Watt
Distribution  Effic. S./M.H.  Effic. S./M.H.  Effic. S./M.H.  Effic. S./M.H.  Effic. S./M.H. 
High Pressure Sodium
Narrow 66.3% 0.5:1 66.4% 0.5:1 68.9% 0.5:1 66.4% 0.5:1 — —
Medium 71.3% 1.1:1 71.4% 1.1:1 74.4% 1.7:1 71.4% 1.1:1 71.3% 0.7:1
Wide 73.3% 2.0:1 73.4% 2.0:1 78.0% 2.0:1 73.5% 2.0:1 74.4% 1.4:1

175 Watt 250 Watt 400 Watt 1000 Watt


Distribution  Effic. S./M.H.  Effic. S./M.H.  Effic. S./M.H.  Effic. S./M.H. 
Lighting: General Lighting — Area — High Bay

Metal Halide
Narrow 61.8% 0.4:1 66.7% 0.4:1 61.9% 0.6:1 — —
Medium 66.1% 1.0:1 70.2% 1.0:1 66.3% 1.5:1 76.2% 1.1:1
Wide 66.1% 2.0:1 75.2% 2.2:1 66.3% 2.2:1 75.4% 2.5:1
Mercury Vapor
Narrow 73.0% 0.8:1 53.2% 0.8:1 73.1% 1.2:1 — —
Medium 73.5% 1.1:1 63.2% 1.1:1 73.6% 1.4:1 72.1% 1.5:1
Wide 74.2% 1.7:1 68.0% 1.7:1 74.2% 1.7:1 69.5% 1.8:1

Quick-Estimate Illumination Charts 

1000 Watt High Pressure Sodium 1000 Watt Metal Halide 1000 Watt Mercury Vapor
Lighting

How to use Quick-Estimate Illumination Chart


1. Refer to “Quick-Estimate Chart” for the lamp to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. M./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq.M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line
(real or ­interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point
of intersection to horizontal line of number “Square Feet Per Luminaire”. The resulting number (real or interpolated)
is the ­“number of square feet” one Appleton Baymaster will illuminate to the selected average maintained footcandle
level when mounted in ­conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per ­luminaire” number to determine spacing between units.

 S./M.H.: Spacing to Mounting Height.


 Photometric charts available on request.
V CSA Certification only.

1360 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster 1000™ High Bay Luminaires
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

Applications
• Ideal for aircraft hangars, machine shops, foundries and other
large-area working environments.
Features
• Standard Baymaster fixtures operate in high ambient
temperatures.
• High efficiency (up to 76% with 1000 W metal halide lamps) with
exceptionally long lamp life makes these Baymaster fixtures
unusually economical to own and operate.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Mogul base socket with spring loaded center contact and heavy
gauge, screw shell with double lamp grips to prevent lamps
from loosening due to vibration.

Lighting: General Lighting — Area — High Bay


• The Baymaster reflector is a unique design that combines high
efficiency with low glare in a compact size.
• Reflector installs and adjusts to wide or medium distribution
(without tools) by repositioning spring locks.
• Installation is quick and easy:
(1) lift ballast assembly onto the hanger hub and rotate 60° until Complete Fixture
seated on hub
(2) tighten locking nut (hand tight) to secure ballast assembly
(3) make supply connections (194 °F/90 °C wire) and replace
wiring cover
(4) snap reflector in place
(5) install lamp
• Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.
Standard Materials
Ballast Housing Assembly
• Ballast: finned, aluminum
• Sockets: porcelain, nickel plated center contact
• Screws: brass Dimensions
• Reflectors: aluminum
• Locks: stainless steel
Standard Finishes

Lighting
• Ballast: corrosion polyester
26.81”/681.0 mm Min. — 29”/736.6 mm Max.

• Sockets: nickel plated center contact


• Screws: nickel plated
• Reflectors: natural finish
Options
• Units are available with a pre-wired sensor circuit for
automatically lighting an auxiliary safety lamp in case a power
dip or lamp failure extinguishes the HID lamp.
Certifications and Compliances
• UL Listed: E109438
• UL Standard: 1598 (supersedes UL Standard 1572)
• CSA Certified: LR9349
Related Products
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.
20.0"/508.0 mm

Standard Baymaster 1000 fixtures operate


efficiently in high 131 °F/55 °C ambient temperatures.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1361


© September 2010
Baymaster 1000™ High Bay Luminaires
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

Pendant Mounting (3/4”)


Catalog Number
Lamp Type Voltage
Complete Assembly ② Ballast Housing Assembly
For High Pressure Sodium Lamps — Complete with ballast
1000 W HPS 120/208/240/277 V G-HB81AL-MT G-HB811L-MT
1000 W HPS 120/277/347 V G-HB81AL-TT V G-HB811L-TT V
1000 W HPS 480 V G-HB81AL-48 G-HB811L-48
For Metal Halide Lamps — Complete with ballast
1000 W MH  120/208/240/277 V G-HB81AH-MT G-HB811H-MT
1000 W MH  120/277/347 V G-HB81AH-TT V G-HB811H-TT V
Lighting: General Lighting — Area — High Bay

1000 W MH  480 V G-HB81AH-48 G-HB81A1H-48


For Incandescent Lamps or HID Lamps — Ballast Remote — Ballast not included
750 W, 1000 W or 1500 W PS-52 Incandescent G-H81AM-RB G-H811M-RB
1000 W High Pressure Sodium G-H81AL-RB G-H811L-RB
1000 W Metal Halide G-H81AH-RB G-H811H-RB

Electrical Specifications

High Pressure Sodium — C.W.A.  Ballast Amps — 1000 W Metal Halide — C.W.A.  Ballast Amps — 1000 W
Line Volts Start Oper. Total Watts Start Oper. Total Watts
120 6.35 9.50 1100 8.00 9.20 1080
208 3.80 5.50 1100 4.60 5.30 1080
240 3.20 4.80 1100 4.00 4.60 1080
277 2.75 4.20 1100 3.50 4.00 1080
347 2.80 3.00 1100 2.00 3.20 1080
480 1.80 2.45 1100 2.00 2.30 1080
Lighting

Luminaire Performance
1000 W
Distribution  Effic. S./M.H. 
High Pressure Sodium
Medium 71.3% 7:1
Wide 74.4% 1.4:1
Metal Halide
Medium 76.2% 1.1:1
Wide 75.4% 2.5:1

 1000 W MH Lamps: some manufacturers recommend that their lamps be operated in enclosed units only—select enclosing lens
from list of accessories. Contact your electrical lamp distributor or lamp manufacturer for the latest safety information.
 Add suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
 Supplied complete with C.W.A. Ballast. For 208, 240, 480 or 600 V C.W.I. applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
 C.W.A. is Constant Wattage Autotransformer.
 Reflector adjusts for Medium to Wide distribution without tools.
 S./M.H.: Spacing to Mounting Height.
V CSA Certification only.

1362 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Baymaster 1000™ High Bay Luminaires Accessories and Replacement Parts
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

Description Catalog Number ➊


Wire Guard
Zinc plated. G-HB-20-NG

1.0"/
25.4 mm

21.0"/
533.4 mm

Hinged Lens — Complete with Socket Schroud


Thermal shock and impact resistant, clear G-HB-20-NL
glass lens.
1.0"/

Lighting: General Lighting — Area — High Bay


25.4 mm
Thermal shock and impact resistant, G-HB-20-NL3
Corning-73 lens.
20.06"/
509.5 mm

Socket Shroud
2.25"/
57.2 mm 3.0"/ Aluminum (closes off reflector). G-HB7000-SS
76.2 mm

2.88"/
73.2 mm

6.0"/
152.4 mm

Safety Cable (not shown) G-HB7000-SC

Reflector
Reflector only. G-8AW

Lighting
Wiring Kit (not shown)
Supplied with 3 feet of 16/3 SOOW cable PWK V
and FHHM-75SS cast safety hook

➊ Other accessories available for 20”/508 mm 1000 W Baymasters include emergency lighting circuits, unit fuses, and special hanger hardware. Contact your
local sales representative.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1363


© September 2010
Baymaster 1000™ High Bay Luminaires
Quick Estimate Illumination Charts *
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

1000 Watt High Pressure Sodium 1000 Watt Metal Halide

How to use Quick-Estimate Illumination Chart


Lighting: General Lighting — Area — High Bay

1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft./232.3 Sq. M. thru
10,000 Sq. Ft./929.0 Sq. M. A “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated) to
right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
Lighting

* Photometric charts available on request.

1364 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Suitable for use in damp locations

Applications
• Energy-efficient, low-glare illumination for manufacturing,
storage and other indoor areas where low bay luminaires are
required. Can be mounted as low as 8 feet/2.4 meters from
work plane.
• Suitable for use in damp locations.
• Operates safely in ambients as high as 104 °F/40 °C.
• Applications involving airborne particulates (such as carbon
black, pigments, etc.) should be pre-evaluated and approved
by Appleton prior to ordering.
Features
• High efficiency (up to 74.6% with 250 W high pressure
sodium lamp) combined with long lamp life, ensures the most
economical operation.
• Two-to-one vertical-to-horizontal footcandles provides effective,
efficient illumination of vertical surfaces.
• Reflector/refractor optical assembly is computer designed for
uniform, wide light distribution with low glare.
• Injection-molded prismatic refractor lens is 100% virgin acrylic.
Minimum thickness is 3/16”/4.8mm.
• Ruggedly built, attractively styled, low-profile design.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Capable of starting and operating the lamp in temperatures as
low as -20 °F/-28.9 °C for pulse start metal halide lamps, Dimensions
-40 °F/-40 °F for high pressure sodium lamps.

Lighting: General Lighting — Area — Low Bay


• Mogul base socket with spring loaded center contact and heavy /8"/ 6-1/4"/
12-3 mm 158.8 mm
gauge, screw shell with double lamp grips to prevent lamps 314.4
from loosening due to vibration.
• Installation is quick and easy:
(1) mount junction box to 3/4”/19.1 mm conduit
(2) slide ballast onto junction box
(3) make connections 26-3/4"/
(4) install lamp 679.5 mm
(5) snap reflector in place 16.0"/
406.4 mm
Standard Materials
• Gasket: silicone rubber
• Reflector: aluminum
• Ballast housing: finned, coppefree (4/10 of 1% max) aluminum
• Sockets: porcelain 20.0"/
• Screws: brass 508.0 mm

Standard Finishes
• Reflector: natural finish
• Ballast: white powder coat polyester
• Sockets: nickel plated center contact
• Screws: nickel plated brass
Options Related Products
Lighting

• Units are available with a pre-wired sensor circuit for • For power hook, fusing and other suspension accessories see
automatically lighting an auxiliary safety lamp in case a power Fixture Hanger Accessories.
dip or lamp failure extinguishes the HID lamp.
Certifications and Compliances
• UL Listed: E85142
• UL Standard: 1598
• CSA Certified: LR9349

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1365


© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Suitable for use in damp locations

Electrical Specifications
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
150 W 250 W
Total Total
Line Volts Start Oper. Watts Start Oper. Watts
120 2.00 1.70 188 2.00 2.50 295
208 1.15 .95 188 1.20 1.50 295
240 1.00 .85 188 1.00 1.30 295
277 .85 .72 188 .85 1.10 295
347 V 0.52 0.56 188 0.60 0.93 295
480 .50 .47 189 .40 .65 295
Pulse Start Metal Halide — Super C.W.A. Ballast Amps
175 W 200 W 250 W
Line Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 .90 1.78 199 2.10 2.00 235 1.90 2.50 288
208 .50 1.08 199 1.15 1.25 235 1.10 1.45 288
240 .35 .89 199 1.10 1.00 235 .96 1.25 288
277 .30 .76 199 .75 .85 235 .85 1.10 288
Lighting: General Lighting — Area — Low Bay

347 V 0.25 0.65 199 .25 .70 232 0.62 0.90 288
480 .25 .50 213 .35 .50 237 .46 .60 285
Metal Halide V — C.W.A. Ballast Amps
175 W 250 W
Line Total Total
Volts Start Oper. Watts Start Oper. Watts
120 1.3 1.8 213 1.2 2.6 295
208 .75 1.1 213 .65 1.5 295
240 .65 .90 213 .60 1.3 295
277 .55 .78 213 .50 1.12 295
347 0.50 0.65 213 0.80 0.90 295

Luminaire Performance
150 Watt 175 Watt 200 Watt 250 Watt
Distribution S./M.H. S./M.H. S./M.H. S./M.H.
 Effic.  Effic.  Effic.  Effic. 
Lighting

High Pressure Sodium


70.0% 3.2:1 — — — — 74.6% 3.1:1
Pulse Start Metal Halide
— — 65.9% 2.7:1 53.1% 3.1:1 67.2% 3.0:1
Metal Halide
— — 62.3% 2.6:1 — — 64.7% 3.0:1
 Reflector adjusts for medium to wide distribution without tools.
 S./M.H.: Spacing to Mounting Height.
V CSA Certified only.

1366 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Suitable for use in damp locations

Pendant Mounting
Catalog Number
Complete with Reflector/Refractor Ballast Housing
Lamp Type Voltage Assembly and Ballast  Assembly
For High Pressure Sodium Lamps
150 W HPS 120/208/240/277 V  G-LM41AL-MT G-LM411L-MT
150 W HPS 120/277/347 V  G-LM41AL-TT V④ G-LM411L-TT V④
150 W HPS 480 V  G-LM41AL-48 G-LM411L-48
250 W HPS 120/208/240/277 V G-LM61AL-MT G-LM611L-MT
250 W HPS 120/277/347 V G-LM61AL-TT V④ G-LM611L-TT V④
250 W HPS 480 V G-LM61AL-48 G-LM611L-48
For Pulse Start Metal Halide Lamps
175 W PSMH 120/208/240/277 V G-LM51AP-MT G-LM511P-MT
175 W PSMH 120/277/347 V G-LM51AP-TT V④ G-LM511P-TT V④
175 W PSMH 480 V G-LM51AP-48 G-LM511P-48
200 W PSMH 120/208/240/277 V G-LM201AP-MT G-LM2011P-MT
200 W PSMH 120/277/347 V G-LM201AP-TT V④ G-LM2011P-TT V④
200 W PSMH 480 V G-LM201AP-48 G-LM2011P-48

Lighting: General Lighting — Area — Low Bay


250 W PSMH 120/208/240/277 V G-LM61AP-MT G-LM611P-MT
250 W PSMH 120/277/347 V G-LM61AP-TT V④ G-LM611P-TT V④
250 W PSMH 480 V G-LM61AP-48 G-LM611P-48
For Metal Halide Lamps V
175 W MH 120/208/240/277 V G-LM51AH-MT V G-LM511H-MT V
175 W MH 120/277/347 V G-LM51AH-TT V④ G-LM511H-TT V④
250 W MH 120/208/240/277 V G-LM61AH-MT V G-LM611H-MT V
250 W MH 120/277/347 V G-LM61AH-TT V④ G-LM611H-TT V④

Lighting

 For 150 W HPS fixtures furnished with Instant Hot Restart, add suffix -R to catalog number.
 Add Suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
 To order fixture complete with lamp, add suffix -L to catalog number.
④ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1367


© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Accessories and Replacement Parts


Type Description Catalog Number
Fuseholder with 9” wire leads

Zinc plated. G-F10


1- 3.3
3
5/ m
16 m
"/

Safety Cable (not shown) G-HB7000-SC


Optic Assembly

Optic Assembly only. G-LM20

Wiring Kit (not shown)


Supplied with 3 feet of 16/3 SOOW cable and FHHM-75SS cast safety
hook PWK V
Lighting: General Lighting — Area — Low Bay
Lighting

V CSA Certification only.

1368 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. Quick-Estimate Illumination Chart *
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH.

250 Watt High Pressure Sodium 150 Watt High Pressure Sodium

250 Watt Pulse Start Metal Halide 175 Watt Pulse Start Metal Halide

Lighting: General Lighting — Area — Low Bay


How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. Ft./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq.M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line
(real or interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point
of intersection to horizontal line of number “Square Feet Per Luminaire.” The resulting number (real or interpolated) is
the “number of square feet” one Appleton will illuminate to the selected average maintained footcandle level when
mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.

Lighting

* Photometric charts available on request. Consult your local sales representative for pulse start metal halide.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1369


© September 2010
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

Suitable for use in damp locations

Applications
• Energy-efficient, low-glare illumination for manufacturing,
storage and other indoor areas where low bay luminaires are
required. Can be mounted as low as 8 feet/2.4 meters from
work plane.
• Suitable for use in damp locations.
• Operates safely in ambients as high as 104 °F/40 °C
• Applications involving airborne particulates (such as carbon
black, pigments, etc.) should be pre-evaluated and approved by
Appleton prior to ordering.
Features
• High efficiency (up to 81.6% with 400 W high pressure
sodium lamp) combined with long lamp life, ensures the most
economical operation.
• Two-to-one vertical-to-horizontal footcandles provides effective,
efficient illumination of vertical surfaces.
• Reflector/refractor optical assembly is computer designed for
uniform, wide light distribution with low glare.
• Injection-molded prismatic refractor lens is 100% virgin acrylic.
Minimum thickness is 3/16”/4.8 mm.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Capable of starting and operating the lamp in temperatures as
low as -20 °F/-28.9 °C for pulse start metal halide lamps,
-40 °F/-40 °C for high pressure sodium lamps.
• Mogul base sockets with spring loaded center contact and
Lighting: General Lighting — Area — Low Bay

Dimensions
heavy gauge screw shell with double lamp grips to prevent
lamps from loosening due to vibration. 6.25"/ 12.38"/
• Installation is quick and easy: 158.8 mm 314.5 mm
(1) mount junction box to 3/4”/4.8 mm conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp
(5) snap reflector in place 26.0"/660.4 mm
Standard Materials 15.25"/
387.4 mm
• Gasket: silicone rubber
• Reflector: aluminum
• Ballast: finned, copperfree (4/10 of 1% max.) aluminum
• Sockets: heavy duty porcelain
• Screws: brass
30.0"/
Standard Finishes 762.0 mm

• Reflector: natural finish


• Ballast: white powder coated polyester
• Sockets: nickel plated center contact
• Screws: nickel plated
Options
• Units are available with a pre-wired sensor circuit for Related Products
Lighting

automatically lighting an auxiliary safety lamp in case a power • For power hook, fusing and other suspension accessories, see
dip or lamp failure extinguishes the HID lamp. Fixture Hanger Accessories page.
Certifications and Compliances
• UL Listed: E85142
• UL Standard: 1598
• CSA Certified: LR9349

V CSA Certification only.

1370 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

Suitable for use in damp locations

Pendant Mounting
Catalog Number
Complete with Reflector/Refractor Ballast Housing
Lamp Type Voltage Assembly and Ballast  Assembly
For High Pressure Sodium Lamps
250 W HPS 120/208/240/277 V G-LM61BL-MT G-LM611L-MT
250 W HPS 120/277/347 V G-LM61BL-TT V④ G-LM611L-TT V④
250 W HPS 480 V G-LM61BL-48 G-LM611L-48
400 W HPS 120/208/240/277 V G-LM71BL-MT G-LM711L-MT
400 W HPS 120/277/347 V G-LM71BL-TT V④ G-LM711L-TT V④
400 W HPS 480 V G-LM71BL-48 G-LM711L-48
For Pulse Start Metal Halide Lamps
320 W PSMH 120/208/240/277 V G-LM321BP-MT G-LM3211P-MT
320 W PSMH 120/277/347 V G-LM321BP-TT V④ G-LM3211P-TT V④
320 W PSMH 480 V G-LM321BP-48 G-LM3211P-48
400 W PSMH 120/208/240/277 V G-LM71BP-TT V④ G-LM711P-MT
400 W PSMH 120/277/347 V G-LM71BP-MT G-LM711P-TT V④
400 W PSMH 480 V G-LM71BP-48 G-LM711P-48
For Metal Halide Lamps V

Lighting: General Lighting — Area — Low Bay


400 W MH 120/208/240/277 V G-LM71BH-MT V G-LM711H-MT V
400 W MH 120/277/347 V G-LM71BH-TT V④ G-LM711H-TT V④

Accessories and Replacement Parts 


Type Description Catalog Number
Fuseholder with 9” wire leads

Zinc plated. G-F10


1- 3.3
3
5/ m
16 m
"/

Safety Cable (not shown) G-HB7000-SC


Optic Assembly

Optic Assembly only. G-LM30


Lighting

Wiring Kit (not shown)


Supplied with 3 feet of 16/3 SOOW cable and FHHM-75SS cast
safety hook PWK V

 To order fixture complete with lamp, add suffix -L to catalog number.


 Add Suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
 For power hook, fusing and other suspension accessories, see Fixture Hanger Accessories.
④ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1371


© September 2010
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

Suitable for use in damp locations

Electrical Specifications
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
250 W 400 W
Line Volts Start Oper. Total Watts Start Oper. Total Watts
120 2.00 2.50 295 3.30 3.80 465
208 1.20 1.50 295 1.80 2.20 465
240 1.00 1.30 295 1.60 1.90 465
277 .85 1.10 295 1.40 1.70 465
347 V 0.60 0.93 295 1.00 1.32 465
480 .40 .65 295 .80 1.00 465

Pulse Start Metal Halide — Super C.W.A. Ballast Amps


Line 320 W 400 W
Volts Start Oper. Total Watts Start Oper. Total Watts
120 2.60 3.25 368 3.50 4.00 454
208 1.50 1.90 368 2.00 2.30 454
240 1.30 1.65 368 1.75 2.00 454
277 1.15 1.40 368 1.50 1.75 454
Lighting: General Lighting — Area — Low Bay

347 V 0.70 1.10 368 1.10 1.35 454


480 .60 .80 368 .90 1.00 454

Metal Halide V — C.W.A. Ballast Amps


Line 400 W
Volts Start Oper. Total Watts
120 3.25 4.0 458
208 1.9 2.3 458
240 1.65 2.0 458
277 1.4 1.75 458
347 1.20 1.40 458

Luminaire Performance 
250 Watt 320 Watt 400 Watt
Distribution Effic. S./M.H.  Effic. S./M.H.  Effic. S./M.H. 
High Pressure Sodium
Lighting

Wide 81.7% 2.0:1 — — 81.6% 2.0:1


Pulse Start Metal Halide
Wide — — 63.7% 2.3:1 63.2% 2.3:1
Metal Halide V
Wide — — — — 81.4% 1.7:1

V CSA Certified only.

1372 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. Quick Estimate Illumination Charts *
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

250 Watt High Pressure Sodium 400 Watt High Pressure Sodium

320 Watt Pulse Start Metal Halide 400 Watt Pulse Start Metal Halide

Lighting: General Lighting — Area — Low Bay


How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. Ft./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line
(real or interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point
of intersection to horizontal line of number “Square Feet Per Luminaire.” The resulting number (real or interpolated) is
the “number of square feet” one Appleton will illuminate to the selected average maintained footcandle level when
mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
Candlepower Distribution of 400 W HPS Luminaire — Closed Bottom Acrylic — All data based on clear, mogul base lamp
Fixture Efficiency: 81.6% Zone Candlepower Zone Candlepower
5 7861 95 667
15 7806 105 328
25 9774 115 184
35 11404 125 82
Lighting

45 10612 135 32
55 7257 145 20
65 4998 155 0
75 3214 165 0
85 1625 175 0

* Photometric charts available on request. Consult your local sales representative for pulse start metal halide.
 Consult your local sales representative for performance with 400 W mercury vapor lamps.
 S./M.H.: Spacing to Mounting Height.
V CSA Certified only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1373


© September 2010
Fixture Hanger Accessories
Baymaster, Lumenmaster, Super-Baymaster

Catalog Number
Voltage Fits Hubbell Plug No. Pendant Feed-Thru
GHPHP Pendant with one 3/4”/19.1 mm hub, GHPHT with two 3/4”/19.1 mm hubs
Furnished with assembled FS box, EFHM safety lock, receptacle and steel cover. Supports 200 lbs/90.7 kgs.
120 L5-15P GHPHP12 GHPHT12
208, 240 L6-15P GHPHP24 GHPHT24
8.50"/ 277 L7-15P GHPHP27 GHPHT27
215.9 mm 6.06"/
153.9 mm
480 L8-20P GHPHP48 GHPHT48

Cord Length
Voltage Fits Hubbell Receptacle No. Ft/M Catalog Number
Matching Cord Sets for above Receptacle Hangers
2/.6 G-HCPL-2-12
120 L5-15R 3/.9 G-HCPL-3-12
4/1.2 G-HCPL-4-12
2/.6 G-HCPL-2-24
208, 240 L6-15R 3.9 G-HCPL-3-24
4/1.2 G-HCPL-4-24
2/.6 G-HCPL-2-27
Lighting: General Lighting — Area — Low Bay

277 L7-15R 3/.9 G-HCPL-3-27


4/1.2 G-HCPL-4-27
2/.6 G-HCPL-2-48
480 L8-20R 3/.9 G-HCPL-3-48
4/1.2 G-HCPL-4-48
Size Length (A) Support Wt.
(Inches) Inch/Millimeters Lbs/Kgs Catalog Number
FH—Hanger Loops With 5/8”/16.0 mm wire opening
FHLM—Male
1/2 3.88/98.6 350/158.8 FHLM-50
3/4 4.13/104.9 FHLM-75
FHLF—Female
1/2 3.25/82.6 FHLF-50
3/4 3.25/82.6 350/158.8 FHLF-75
FH—Hanger Hooks With 5/8”/16.0 mm wire opening, 3/8”/19.1 mm jaw opening
FHHM—Male
1/2 3.88/98.6 200/90.7 FHHM-50
3/4 4.13/104.9 FHHM-75
Lighting

FHHF—Female
1/2 3.25/82.6 200/90.7 FHHF-50
3/4 3.25/82.6 FHHF-75
Fuse and Cartridge — Cartridges are furnished complete with two 10”/254 mm-long high temperature wire leads and 600 Volt fuse
6 Amp G-F6
10 Amp G-F10
20 Amp G-F20
30 Amp G-F30

1374 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Quartzlite™ 50 Floodlight
300 W thru 500 W quartz tungsten halogen.

Applications
• Recreation — fun after dark with illuminated swimming pools,
basketball, and other court and play areas.
• Beauty — illuminate your home, patio and garden to maximize
the beauty of your home.
• Safety — eliminate night-time hazards with lighting on outdoor
stairways, walkways, and driveways.
• Security — illuminate backyards, entrance ways and other
areas for protection against intruders.
• Saves energy.
Features
• Uses standard household current (120 Volts, 120 Vac).
• Strong, compact, lightweight fixture can be installed
anywhere outdoors.
• Bright anodized aluminum parabolic reflector for efficient
light distribution.
• Lamp held securely in spring-loaded porcelain socket Dimensions
for positive contact. 9.0"/
• Flowing lines for an attractive appearance blend with 228.6 mm
5.63"/143.0 mm
any architectural style.
• Reinforcing rib keeps lens door flat against housing.
• Door hinges cast permanently as part of the housing securely 7.75"/196.9 mm
anchor door, yet entire door can be removed if desired.
• Easy to install 1/2” NPT thread with locknut.
• Attaches to standard electrical box cover plate (not furnished).
Only two wires plus ground to connect. 2.13"/
54.1 mm

Standard Materials 0.5"/12.7 mm

• Housing and lens door: single pressure — cast aluminum piece


• Lens: heat/shatter resistant glass
• Slotted/hex screw:
• Adjustable swivel mount
Certifications and Compliances
• UL Listed: E22558
• UL Standard: 1598
• CSA Certified: LR9349

Lighting: General Lighting — Area — Floodlights


Candlepower Catalog Number
Description NEMA Type Lumens Max. Average Max. With Lamp Without Lamp
(Illumination based on use of T-3 Quartz Tungsten Halogen Lamps)

Wide Beam 5x5 6,846 8,416 7,685 G-50-5-L120 G-50-5

Area Illuminated Area Illuminated


Mounting Mounting Height Width x Depth Mounting Mounting Height Width x Depth
Angle ft/m ft/m Angle ft/m ft/m
70x70/ 80x75/
12/3.7 12/3.7
21.3x21.3 24.4x22.9
80x80/ 90’x85’
16/4.9 16/4.9
24.4x24.4 27.4x25.9
100x80/ 100’x90’
20/6.1 20/6.1
30.5x24.4 30.5x27.4
Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1375


© September 2010
Quartzlite™ 500/1500 Floodlight
300 W thru 1500 W quartz tungsten halogen lamps.

Applications
• Heavy duty, weatherproof floodlights for industrial, commercial,
and sports applications where efficient, controlled distribution is
required. Widely used for:
— Sports and amusement areas
— Sign lighting
— Parking lots
— Accent lighting
— Security lighting
— Similar applications
Features Quartzlite™ 500 Quartzlite™ 1500
Projected Area: Projected Area:
• Choice of mounting fittings and accessories to meet
installation needs. 1.2 Sq. Ft/0.14 Sq. M 0.7 Sq. Ft/0.07 Sq. M
• Rugged, compact, lightweight design; easy to install and
maintain. Cool operating, long lamp life.
• Quartzlite 500 uses 500 W or 300 W 120 Volts or 130V T-3
quartz tungsten halogen lamps with exceptional efficiency
and economy.
• Quartzlite 1500 uses T-3 quartz tungsten halogen lamps. Dimensions
Available for use with 1500 W lamps for 208, 220, 240, and 277 4.75"/ 4.5"/
120.7 mm
Volt operation; for 1250 W lamps, 208 Volt operation; and for 9.88"/
114.3 mm

1000 W lamps, 220 or 240 Volts operation. 251 mm


15.25"/387.4 mm
• 1500 W unit housing has integral fins for maximum heat
dissipation. Hinged door has thermal shock and impact
10.

resistant glass lens.


75"
/27

Standard Materials
3.1
mm

• Housing and lens door: rugged, corrosion resistant, one-piece 11"/279.4 mm

pressure-cast aluminum
• Hex-head bolts: two 5/16"/8.0 mm 9.5"/ 2.75"/69.9 mm
• Thermal shock and impact resistant glass 241.3 mm

• Gasket: heavy, one-piece silicone rubber to resist high


temperatures
• Reflector: precision parabolic design, natural finish aluminum
for maximum efficiency
• Swivel mounting arm: heavy duty, degree-marked swivel Certifications and Compliances
mounting arm with 3/4”/19.1 mm pipe thread and locknut
Lighting: General Lighting — Area — Floodlights

• UL Listed: E22558
Standard Finishes • UL Standard: 1598
• Housing and hinged lens door: architectural bronze polyester • CSA Certified: LR9349
finish

Beam Spread Candlepower Catalog Number


Average Without
Description NEMA Type Horizontal Vertical Lumens Maximum Maximum With Lamp Lamp
(Illumination based on use of T-3 Quartz tungsten Halogen lamps)
Quartzlite™ 1500
G-1500L240 ➊
Wide Beam 6x6 128.0° 103.0° 23,218 18,689 17,564 G-1500-➌
G-1500L277 ➋
Quartzlite 500

Wide 5x5 95° 92° 6,846 8,416 7,685 G-500-5-L130 ➍ G-500-5 ➎

➊ Furnished with 1500 W lamps for 240 V line operation.


➋ Furnished with 1500 W lamps for 277 V line operation.
➌ For 1500 W lamps for 208, 220, 240 or 277 V line operation; 1250 W lamps for 208 V line operation; 1000 W lamps for 220 or 240 V line operation.
➍ Furnished with 500 W lamps for 120 or 130 V line operation.
Lighting

➎ For 300 W or 500 W lamps for 120 or 130 V line operation.

1376 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Quartzlite™ 500/1500 Floodlight Mounting Fittings and Accessories
300 W thru 1500 W quartz tungsten halogen lamps.

Description Catalog Number


Crossarm Mount and Wiring Compartment
2.63"/
66.8 mm

1.88"/
180° horizontal position scale, mounts with bolt (not furnished).
47.8 mm Aluminum with architectural bronze polyester finish. Includes cord G-6028N
grip.
3.0"/ 3.88"/
76.2 mm 98.6 mm

Pipe or Wall Mount Bracket


4.0"/
101.6 mm
Mounts on 1” to 2”/25.4 to 50.8 mm pipe, vertical or horizontal,
3.75"/
or mounts on flat surfaces (used with G-6028N). Includes U-bolts
95.3 mm G-VB101
and bolt for G-6028N. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
4.25"/108.0 mm

Top Visor
5.0"/
127 mm

2.5"/
63.5 mm 500 W GMM4V
8.63"/
219.2 mm

Wire Guard

500 W G-506

Channel Crossarm
2.5"/63.5 mm
2.75"/
69.9 mm
Extruded aluminum, with slide-off cover. Has six 3/4”/19.1 mm
threaded holes, with three close-up plugs. Mounts five 500 W or
G-6017

Lighting: General Lighting — Area — Floodlights


26.0"/
660.4 mm four 1500 W Quartzlites. Mounts on 3/4”/19.1 mm conduit or G-810
poletop fitter.

Poletop Fitter
3.0"/
76.2 mm

Cast aluminum, for mounting to 1-1/2” or 2”/38.1 to 50.8 mm pip


Has setscrews for securing to pole, 3/4”/19.1mm tapped top hub to
G-810
2.25"/ accommodate Quartzlite or Channel Crossarm above. Architectural
57.2 mm
bronze polyester finish.

Replacement Lens Frame Assembly


500 W G5005RFL
1500 W G1500RFL
Replacement Lens

500 W 601252002

1500 W 601252001
Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1377


© September 2010
Quartzlite™ 500/1500 Floodlights
Quick — Estimate Illumination Table *
300 W thru 1500 W quartz tungsten halogen lamps.

Quartzlite™ 500
D=10 Feet/3.0 Meters D=20 Feet/6.1 Meters D=40 Feet Spread/12.2 Meters Spread
Beam Spread
A B L W X A B L W X A B L W X
24/ 19/ 10/ 48/ 38/ 21/ 96/ 77/ 42/
Wide 77 44 19 11 5 3
7.3 5.8 3.0 14.6 11.6 6.4 29.3 23.5 12.8
D=80 Feet/24.4 Meters D=100 Feet/30.5 Meters D=200 Feet/71.0 Meters
Lighting: General Lighting — Area — Floodlights

A B L W X A B L W X A B L W X
192/ 153/ 83/ 240/ 190/ 104/ 481/ 383/ 208/
Wide 1.2 .7 .8 .4 .2 .1
58.5 46.6 25.3 73.2 57.9 31.7 146.6 116.7 63.4

Quartzlite™ 500

D=10 Feet/3.0 Meters D=20 Feet/6.1 Meters D=40 Feet Spread/12.2 Meters Spread
Beam Spread
A B L W X A B L W X A B L W X
33/ 24/ 13/ 67/ 48/ 25/ 133/ 95/ 51/
Wide 176 74 44 19 11 5
10.1 7.3 4.0 20.4 14.6 7.6 40.5 29.0 15.5
D=80 Feet/24.4 Meters D=100 Feet/30.5 Meters D=200 Feet/71.0 Meters
A B L W X A B L W X A B L W X
266/ 191/ 102/ 333/ 238/ 127/ 666/ 477/ 255/
Wide 3 1.2 1.7 0.7 .4 .2
81.1 58.2 31.1 101.5 72.5 38.7 203.0 145.4 77.7
Note: To simplify proper beam overlapping, the size of “X” has been determined so that footcandles at edge (B) are approximately 1/3 of center intensity (A).

* Photometric charts available on request.


Lighting

1378 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster Jr.™ HID Wide-Beam Floodlights
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Applications
• Available for use with HPS or PSMH medium base lamps.
• HPS luminaires, with their superior energy efficiency are
excellent for such applications as:
— Security lighting
— Small sports areas
— Parking areas
— Apartment complexes
— Hotels and motels
— Work area lighting
— Accent, building facade and sign lighting
• PSMH luminaires, with their near perfect color rendition, are
recommended for:
— Car lots
— Garden shops
— Small sports areas
— Billboards
— Building facades
— Airports Projected Area: 0.7 Sq. Ft.
— Security areas
• HPS and PSMH floodlights replace higher wattage, inefficient
quartz and PAR lighting.
• Suitable for use in wet locations.
Features
• HPS units use approximately 80% less energy than
incandescent PAR-38 lamps and 70-75% less than quartz
lamps. In lumen output, the 50 W HPS unit is comparable to
two 150 W PAR 38 incandescent lamps; 70 W HPS to 300 W Standard Materials
T-3 quartz; and 100 W HPS to 500 W T-3 quartz.
• Ballast housing, door and mounting arm: diecast heavy gauge
• Beam pattern is NEMA Type 7.
aluminum
• Extra-compact, high efficiency floodlights designed specifically
• Reflector: heavy gauge aluminum
for the small size of HID medium base lamps.
• Lens: heat- and impact-resistant tempered glass
• Compact size permits use of existing poles for retrofitting quartz
• Gasket: heavy, high temperature silicone rubber
fixtures.
• Ruggedly built for dependable, vandal-resistant service. Standard Finishes
Attractively styled. Easy to install, aim, and service, with easy • Reflector: diffused anodized natural finish
access to interior.

Lighting: General Lighting — Area — Floodlights


• Housing, lens door and mounting arm: architectural bronze
• Durable architectural bronze polyester finish resists chipping, polyester finish
peeling and fading no matter what the weather or climate
conditions. Certifications and Compliances
• Mounting arm: heavy duty, degree-marked swivel mounting arm • UL Standard: 1598 (supersedes UL Standard 1572).
with 3/4” pipe thread and locknut. Allows vertical and horizontal • Suitable for use in wet locations
adjustment. Order mounting accessories separately. • CSA Certified: LR9349
• Medium base porcelain socket with nickel-plated contacts.
Rated for 4-KV pulse. Furnished with 392 °F/200 °C leads, pre-
wired to the ballast.
• Reflector: precision parabolic design, natural finish, aluminum
for maximum efficiency.
• Patented hinged door has thermal shock and impact resistant
glass lens, secured within diecast aluminum frame with two
captive stainless hex head steel screws for watertight fit.
• HPF ballasts have non-PCB capacitors.
Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1379


© September 2010
Areamaster Jr.™ HID Wide-Beam Floodlights
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Description Line Voltage Catalog Number


Pulse Start Metal Halide Fixtures
100 Watt Metal Halide HX-Auto Ballast, High Power Factor 120 G-MM350H-12H ➊➋
High Pressure Sodium Fixtures
50 Watt High Pressure Sodium Reactor Ballast 120 G-MM150L-12R
50 Watt High Pressure Sodium Reactor Ballast, High Power Factor 120 G-MM150L-12RH ➊
70 Watt High Pressure Sodium Reactor Ballast 120 G-MM250L-12R
70 Watt High Pressure Sodium Reactor Ballast, High Power Factor 120 G-MM250L-12RH ➊
100 Watt High Pressure Sodium Reactor Ballast 120 G-MM350L-12R
100 Watt High Pressure Sodium Reactor Ballast, High Power Factor 120 G-MM350L-12RH ➊➋
150 Watt High Pressure Sodium Reactor Ballast 120 G-MM450L-12R
150 Watt High Pressure Sodium Reactor Ballast, High Power Factor 120 G-MM450L-12RH ➊➋

Accessories and Replacement Parts


Description Catalog Number

Crossarm Mount
Has wiring compartment, 180° horizontal position scale. Mounts with bolt (not G-6028N
furnished). Aluminum. Includes cord grip.

Channel Crossarm
Extruded aluminum, with slide-off cover. Six 3/4” threaded holes, with three
G-6017
close-up plugs. Mounts five luminaires. Mounts on 3/4” conduit or on G-810
poletop fitter.

Pipe or Wall Mount Bracket


Mounts on 1” to 2” pipe, vertical or horizontal, or mounts on flat surfaces (used
G-VB101
with G6028N) Includes U-bolts and bolt for G-6028N.
Lighting: General Lighting — Area — Floodlights

Malleable iron.

Poletop Fitter
Cast aluminum, for mounting to 1-1/2” or 2” pipe. Has setscrews for securing
G-810
to pole. 3/4” tapped top hub to accommodate luminaire or Channel Crossarm
above.
Wire Guard
G-506
Mounts to lens door with screws furnished. Zinc plated.
Top Visor
G-MM4V
Aluminum. Easy to install with hardware supplied.
Vandal Shield
G-MM-4-VS
UV stabilized polycarbonate, with installation hardware and instructions.
Replacement Lens and Frame Assembly G5005RFL
Replacement Lens Only 59601252002

➊ 208 V, 240 V or 277 V also available. For 208 V, change voltage suffix -12 to -20; for 240 V, change -12 to -24; and for 277 V, change -12 to -27.
Lighting

➋ For 347 V, change voltage suffix -12H to -34 V.

1380 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster Jr.™ HID Wide-Beam Floodlight Specifications
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Line Voltage Type of Ballast Starting Amps Operating Amps Total Watts
100-Watt Metal Halide
120 HX-Auto, High Power Factor 1.22/.44 1.15/.50 129
150-Watt High Pressure Sodium
120 Reactor 4.50 3.20 170
120 Reactor, High Power Factor 2.20 1.50 170
100-Watt High Pressure Sodium
120 Reactor 3.05 2.10 115
120 Reactor, High Power Factor 1.50 1.05 115
70-Watt High Pressure Sodium
120 Reactor 2.10 1.60 83
120 Reactor, High Power Factor 0.89 0.75 86
50-Watt High Pressure Sodium
120 Reactor 1.80 1.18 62
120 Reactor, High Power Factor 0.95 0.55 60

Dimensions

Lighting: General Lighting — Area — Floodlights

Crossarm Mount Channel Crossarm Pipe/Wall Mount Bracket Poletop Fitter


Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1381


© September 2010
Areamaster Jr.™ HID Wide-Beam Floodlight Photometric Data
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Fixture Wattage and HID Lamp—All Medium Base Clear. All Fixtures produce NEMA Type 7 Beam Pattern.
Photometric Data 150 W HPS 100 W HPS 70 W HPS 50 W HPS 100 W PSMH
Horizontal Spread 146° 146° 146° 146° 136°
Beam Lumens 10,150 6036 3676 2536 4864
Beam Efficiency 63% 64% 63% 63% 68%
Maximum CP 5750 3415 2084 1437 3039
Average Maximum CP 5317 3158 1927 1328 2581
Total Lumens 10,422 6186 3746 2576 4972
Total Efficiency 65% 65% 65% 64% 69%

Candlepower Distribution All data based on fixture with clear medium base lamp
150-Watt High Pressure Sodium 100-Watt Metal Halide
0° Candela Table 0° Candela Table
Angle Horizontal Vertical Angle Horizontal Vertical
-85.5 102 13 -76.6 96 11
-76.5 175 112 -68.0 233 285
-67.5 1224 450 -60.0 415 417
-58.5 1972 774 -52.0 772 536
-49.5 2319 1280 -44.0 1471 660
-40.5 2707 2070 -36.0 2226 1269
-31.5 3302 3838 -28.0 2641 1442
-22.5 4091 4842 -20.0 2729 1662
-13.5 4888 5252 -12.0 2537 1957
-4.5 5334 5390 -4.0 2296 2226
0.0 5388 5388 0.0 2273 2273
4.5 5334 5390 4.0 2296 2226
13.5 4888 5252 12.0 2537 1957
22.5 4091 4842 20.0 2729 1662
31.5 3302 3838 28.0 2641 1442
40.5 2707 2070 36.0 2226 1269
49.5 2319 1280 44.0 1471 660
58.8 1972 774 52.0 772 536
67.5 1224 450 60.0 415 417
76.5 175 112 68.0 233 285
Lighting: General Lighting — Area — Floodlights

85.5 102 13 76.0 96 11


100-Watt High Pressure Sodium
0° Candela Table
Angle Horizontal Vertical
-85.5 61 8
-76.5 104 67
-67.5 727 267
-58.5 1171 459
-49.5 1378 760
-40.5 1608 1229
-31.5 1961 2280
-22.5 2430 2876
-13.5 2903 3119
-4.5 3168 3201
0.0 3200 3200
4.5 3168 3201
13.5 2903 3119
22.5 2430 2876
31.5 1961 2280
40.5 1608 1229
49.5 1378 760
58.5 1171 459
67.5 727 267
76.5 104 67
Lighting

85.5 61 8

1382 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Beam-Master™ Floodlights
General Purpose and Heavy Duty.
Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.

Applications
• To illuminate large areas such as:
— Building facades
— Ship loading docks
— Truck terminals
— Security lighting
— Airports
— Athletic stadiums
— Sports fields
Features
• General purpose and heavy duty units available for 400 W
PSMH, 1000 W or 1500 W metal halide lamps or 400 W and
1000 W high pressure sodium lamps. Choice of five different
NEMA beam spreads (1000 W HPS, two beam spreads; 400 W
MH, three beam spreads.)
• Compact design combines reflector assembly and ballast
housing as a single unit — easier to wire and install.
• Balanced weight distribution allows swing-over design for
easy relamping and servicing.
• Sturdy and rugged — withstands high vibration and rugged
usage.
• Breather openings allow unit to breathe, yet keep dirt and
moisture out.
• Floodlights have aiming device, plus 180° vertical positioning
scale. Fully adjustable horizontally with crossarm bracket or
poletop mount.
• Swing-over design with a “memory” locking device for accurate Mounting Options
return to pre-aimed position after servicing.
• Mogul base porcelain socket has heavy gauge brass, nickel
plated, double lamp-grip screw shell and spring-loaded center
contact.
• Heavy duty models have heavy shroud for protection against
severe weather, such as high winds and hail.
• Cord enters through a weatherproof cord grip.
• Yoke is rugged 6061-T6 aluminum alloy. Crossarm bracket and
poletop slip-fitter are malleable iron. Poletop Slip-Fitter Mounting Crossarm Mounting
• Ballasts are Class H insulated, UL Listed, C.W.A. type, available

Lighting: General Lighting — Area — Floodlights


multi-tapped 120, 208, 240, or 277 Volts, or single-tap for 480
Volts.
Standard Materials
• Refllectors: aluminum
• Lens: shock and impact resistant glass
• Gasket: one-piece silicone rubber gasket
• Frame and clamps: stainless steel
• Socket/ballast: cast aluminum
• Housing: mallaeble Iron
Standard Finishes
• Reflectors: natural finish
• Ballast: white powder coated polyester finish
• Housing: zinc plated, chromate sealed, architectural bronze
polyester finish
Certifications and Compliances
• UL Listed: E85142
• UL Standard: 1598
• CSA Certified: LR9349
Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1383


© September 2010
Beam-Master™ Floodlights
General Purpose and Heavy Duty.
Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.

NEMA Beam Spread Beam Candlepower Line Catalog Number


Type Horiz x Vert. Lumens Beam Effic. Avg. Max. CP Max CP Voltage General Purpose Heavy Duty
With Ballast for 1000 W Metal Halide Lamp
120/208/240/277 G-SM821H-MTN ➊ G-SM821HH-MTN ➊
II 20.2° x 21.1° 37,577 34.2% 1,332,312 1,547,349
480 G-SM821H-48N G-SM821HH-48N
120/208/240/277 G-SM831H-MTN ➊ G-SM831HH-MTN ➊
III 45.1° x 45.1° 55,104 50.1% 481,977 638,600
480 G-SM831H-48N G-SM831HH-48N
120/208/240/277 G-SM841H-MTN ➊ G-SM841HH-MTN ➊
IV 58.6° x 59.3° 61,562 56.0% 213,277 266,126
480 G-SM841H-48N G-SM841HH-48N
120/208/240/277 G-SM851H-MTN ➊ G-SM851HH-MTN ➊
V 73.6° x 74.0° 66,843 60.8% 128,822 160,661
480 G-SM851H-48N G-SM851HH-48N
120/208/240/277 G-SM861H-MTN ➊ G-SM861HH-MTN ➊
VI 111.5° x 111.2° 74,020 67.3% 76,050 82,363
480 G-SM861H-48N G-SM861HH-48N
With Ballast for 1500 W Metal Halide Lamp
120/208/240/277 G-SM921H-MTN ➊ G-SM921HH-MTN ➊
II 20.2° x 21.1° 52,950 34.2% 1,877,349 2,180,356
480 G-SM921H-48N G-SM921HH-48N
120/208/240/277 G-SM931H-MTN ➊ G-SM931HH-MTN ➊
III 45.1° x 45.1° 77,646 50.1% 679,149 899,846
480 G-SM931H-48N G-SM931HH-48N
120/208/240/277 G-SM941H-MTN ➊ G-SM941HH-MTN ➊
IV 58.6° x 59.3° 86,746 56.0% 300,526 374,996
480 G-SM941H-48N G-SM941HH-48N
120/208/240/277 G-SM951H-MTN ➊ G-SM951HH-MTN ➊
V 73.6° x 74.0° 94,188 60.8% 181,522 226,386
480 G-SM951H-48N G-SM951HH-48N
120/208/240/277 G-SM961H-MTN ➊ G-SM961HH-MTN ➊
VI 111.5° x 111.2° 104,301 67.3% 107,161 116,057
480 G-SM961H-48N G-SM961HH-48N
With Ballast for 400 W Pulse Start Metal Halide Lamp
120/208/240/277 G-SM721P-MTN ➊ G-SM721PH-MTN ➊
II 20.9° x 20.1° 14,538 36.3% 345,368 528,021
480 G-SM721P-48N G-SM721PH-48N
120/208/240/277 G-SM751P-MTN ➊ G-SM751PH-MTN ➊
V 73.1° x 72.8° 19,566 48.9% 35,090 54,015
Lighting: General Lighting — Area — Floodlights

480 G-SM751P-48N G-SM751PH-48N


VI 108.4° x 99.1° 22,656 66.6% 28,815 34,043 120/208/240/277 G-SM761P-MTN ➊ G-SM761PH-MTN ➊
With Ballast for 1000 W High Pressure Sodium Lamp
120/208/240/277 G-SM851L-MTN ➊ G-SM851LH-MTN ➊
V 69.1° x 65.2° 63,710 45.5% 175,347 302,942
480 G-SM851L-48N G-SM851LH-48N
120/208/240/277 G-SM861L-MTN ➊ G-SM861LH-MTN ➊
VI 110.3° x 104.6° 81,722 58.4% 81,998 107,556
480 G-SM861L-48N G-SM861LH-48N
With Ballast for 400 W High Pressure Sodium Lamp
120/208/240/277 G-SM721L-MTN ➊ G-SM721LH-MTN ➊
II
480 G-SM721L-48N G-SM721LH-48N
120/208/240/277 G-SM731L-MTN ➊ G-SM731LH-MTN ➊
III
480 G-SM731L-48N G-SM731LH-48N
120/208/240/277 G-SM741L-MTN ➊ G-SM741LH-MTN ➊
IV
480 G-SM741L-48N G-SM741LH-48N
120/208/240/277 G-SM751L-MTN ➊ G-SM751LH-MTN ➊
V
480 G-SM751L-48N G-SM751LH-48N
120/208/240/277 G-SM761L-MTN ➊ G-SM761LH-MTN ➊
VI
480 G-SM761L-48N G-SM761LH-48N
Lighting

➊ For tri-tap 120/277/347 V, change suffix -MTN to -TTN V.

1384 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Beam-Master™ Floodlights
General Purpose and Heavy Duty.
Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.

Mounting Fittings and Accessories Dimensions


Dimensions Description Catalog Number
Crossarm Mounting Bracket
5.0"/
127.0 mm
24.00"/609.6 mm
180° horizontal adjustment—
21.00"/533.4 mm
degree-marked. Facilitates mounting
2.31"/
58.7 mm floodlight to crossarm or other flat G-AM-8-CA
surface, or to G-AM-8-WB. Includes

22.88"/581.2 mm
4.44"/ floodlight yoke bolts.
112.8 mm

Poletop Slip-Fitter
3.5"/
88.9 mm

4.5"/ Slip-fits 2” or 2-1/2”/50.8 or 63.5 mm


114.3 mm
6.0"/127.0 mm
poletop tenons. Includes floodlight yoke G-AM-8-SF
bolts, 3 locking bolts and cord grip.

4.0"/101.6 mm

Pipe or Wall Mount Bracket


4.88"/ 5.0"/
124.0 mm 127.0 mm
Used with G-AM-8-CA. Clamps to 1”
3.0"/ to 2”/25.4 to 50.8 mm pipe, vertical or
76.2 mm horizontal, or mounts on flat surfaces. G-AM-8-WB
5.5"/139.7 mm Includes U-bolt and crossarm bracket
bolts.
4.5"/
114.3 mm

Fuse and Cartridge


Cartridges are furnished complete with
two 10”/254 mm-long high temperature

Lighting: General Lighting — Area — Floodlights


wire leads and 600 Volt fuse.
10 Amp. G-F10
20 Amp G-F20

Electrical Specifications
Metal Halide — C.W.A. ➋ Ballast Amps High Pressure Sodium — C.W.A. ➋ Ballast Amps
400 W 1000 W 1500 W 400 W 1000 W
Line Total Total Total Total Total
Volts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts Start Oper. Watts
120 3.25 4.00 458 8.0 9.20 1080 13.50 14.0 1610 3.30 3.80 465 6.35 9.50 1100
208 1.90 2.30 458 4.6 5.30 1080 7.70 8.00 1610 1.80 2.20 465 3.80 5.50 1100
240 1.90 2.00 458 4.0 4.60 1080 6.70 7.00 1610 1.60 1.90 465 3.20 4.80 1100
277 1.40 1.75 458 3.50 4.00 1080 5.90 6.00 1610 1.40 1.70 465 2.75 4.20 1100
480 .85 1.00 465 2.00 2.30 1080 2.25 3.50 1610 .80 1.00 465 1.80 2.45 1100
Lighting

➋ C.W.A.—Constant Wattage Autotransformer.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1385


© September 2010
Wallmaster™ HPS/PSMH Luminaires
Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.
Lighting
Lighting: General Lighting — Area — Architectural

Applications
• Totally enclosed luminaires for public security installations.
Tough polycarbonate refractor provides vandal resistance.
• Ideal where illumination over wide areas adjacent to walls
is required. Applications include walkways, parking lots
and garages, building exteriors, shopping centers, stores,
restaurants, tunnels, underpasses, loading docks, ramps,
security lighting areas, entrances and recreational areas.
Features
• Computer designed optical system. Reflector provides optimum
down and out light distribution. Prismatic refractor provides soft
light with even distribution, reducing glare.
• Contemporary architectural design with attractive bronze
polyester finish. Soft, diffused light enhances the beauty of any
architectural setting.
• Enclosed and gasketed for use in wet locations—indoors and
out. High temperature neoprene gasketing.
• Easy to maintain. Hinged lens frame swings open (just loosen
two captive bolts) for fast, easy relamping and access to Dimensions
internal components.
• Quick, easy installation. Fixture bolts to any flat surface or
18.0"/
any standard 3” or 4”/76.2 or 101.6 mm outlet box for vertical 457.2 mm
mounting.
• High energy efficiency. High pressure sodium lamps use 9.81"/
approximately one-fourth as much electrical energy as 249.2 mm
incandescent lamps.
• Pre-wired, integrally ballasted.
6.38"/
• Complete assemblies available with a choice of ballasts: high 162.1 mm
4.88"/
reactance high power factor—with or without photocontrol 124.0 mm
(automatic ON–OFF operation). High power factor ballasts 15.13"/
384.3 mm
provide a minimum 90% P.F. and are suitable for use in high
ambient temperature areas. High reactance high power factor
.49 Sq.Ft./0.05 Sq. M
ballasts are single-tap (120 or 480 Vac), dual tap (120/277 Vac) .51 Sq.Ft./0.05 Sq. M
and multi-tap (120-277 Vac). Reactor and reactor high power 2.88"/ 6.88"/
factor ballasts are 120 Vac. 73.2 mm 174.8 mm
• Glass thermal barrier in 100 W and 150 W units protects
polycarbonate lens from heat for longer lens life.
• Tough, molded polycarbonate refractor provides cool fixture
operation.
• Three knockouts provided for conduit and wiring.
• Medium base porcelain socket with spring loaded nickel plated
contacts.
Standard Materials Certifications and Compliances
• Ballast housing and wall bracket: aluminum • UL Standard: E85142
• Hinged lens assembly: high Impact, non-solarizing, • UL Standard: 1598
polycarbonate • CSA Certified: LR9349
• Reflector: aluminum
Standard Finishes
• Ballast housing, wall bracket: two-coat bronze polyester finish
• Reflector: natural finish
Options
• Photocontrol provides automatic ON-OFF operation. Order
luminaires with -PC suffix or add -PC suffix to any 120 Volt
luminaire catalog numbers.

† For multi-tap ballast specify voltage to be used.

1386 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Wallmaster™ HPS/PSMH Luminaires
Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.

Lighting
Lighting: General Lighting — Area — Architectural
Catalog Number
Description Line Voltage Vertical Mount Horizontal Mount Vertical Mount V
50-Watt High Pressure Sodium
Reactor Ballast  120 V G-WM130L-12R G-WM134L-12R G-WMM50L-R1 V
Reactor Ballast, High Power Factor  120 V G-WM130L-12RH G-WM134L-12RH G-WMM50L-H1 V
70-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor 120/208/240/277 V G-WM230L-MT G-WM234L-MT G-WMM70L-MT V
High Reactance Ballast, High Power Factor 480 V G-WM230L-48 G-WM234L-48 Not Available
Reactor Ballast  120 V G-WM230L-12R G-WM234L-12R G-WMM70L-R1 V
Reactor Ballast, High Power Factor  120 V G-WM230L-12RH G-WM234L-12RH G-WMM70L-H1 V
100-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor 120/208/240/277 V G-WM330L-MT G-WM334L-MT G-WMM10L-MT V
High Reactance Ballast, High Power Factor 480 V G-WM330L-48 G-WM334L-48 Not Available
Reactor Ballast  120 V G-WM330L-12R G-WM334L-12R G-WMM10L-R1 V
Reactor Ballast, High Power Factor  120 V G-WM330L-12RH G-WM334L-12RH G-WMM10L-H1 V
150-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor 120/208/240/277 V G-WM430L-MT G-WM434L-MT Not Available
High Reactance Ballast, High Power Factor 480 V Not Available Not Available Not Available
Reactor Ballast  120 V G-WM430L-12R G-WM434L-12R G-WMM15L-R1 V
Reactor Ballast, High Power Factor  120 V G-WM430L-12RH G-WM434L-12RH G-WMM15L-H1 V
70-Watt Pulse Start Metal Halide
High Reactance Ballast, High Power Factor 120/208/240/277 V G-WM230H-MT G-WM234H-MT G-WMM70H-MT V
100-Watt Pulse Start Metal Halide
High Reactance Ballast, High Power Factor 120/208/240/277 V G-WM330H-MT G-WM334H-MT G-WMM10H-MT V

Wall Mounting Kit


Dimensions Description Catalog Number

4.88"/
124.0 mm

Adapts vertical mount fixtures to horizontal


G-WM-HMK
position.

2.88"/
73.2 mm

 Add suffix -PC for Photocontrol. Provides automatic dusk-to-dawn ON-OFF operation. Specify voltage to be used with photocell, if used with multi voltage
ballast.
 Change the -MT suffix to -TT for tri-tap 120/277/347 V V.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1387


© September 2010
Wallmaster™ HPS/PSMH Luminaire Electrical Specifications
Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.
Lighting
Lighting: General Lighting — Area — Architectural

Line Voltage Type of Ballast Starting Amps Operating Amps Total Watts
50-Watt High Pressure Sodium
120 Reactor 1.80 1.18 60
120 Reactor, High Power Factor 0.75 0.55 60
70-Watt High Pressure Sodium
120/208/240/277 High Reactance, High Power Factor 0.75/0.35 0.81/0.35 91
480 High Reactance, High Power Factor 0.21 0.21 94
120 Reactor 2.25 1.70 87
120 Reactor, High Power Factor 0.85 0.75 82
100-Watt High Pressure Sodium
120/208/240/277 High Reactance, High Power Factor 1.30/.60 1.15/0.50 130
480 High Reactance, High Power Factor 0.33 0.31 135
120 Reactor 3.05 2.40 115
120 Reactor, High Power Factor 1.50 1.05 115
150-Watt High Pressure Sodium
120/208/240/277 High Reactance, High Power Factor 2.00/0.85 1.65/.72 188
480 High Reactance, High Power Factor 0.50 0.47 189
120 Reactor 4.55 3.40 170
120 Reactor, High Power Factor 2.20 1.50 170
70-Watt Pulse Start Metal Halide
120/208/240/277 High Reactance, High Power Factor 0.80/0.39 0.85/0.39 95
100-Watt Pulse Start Metal Halide
120/208/240/277 Constant Wattage Auto transformer (CWA) 1.22/0.44 1.15/0.50 128

1388 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Wallmaster™ HPS/PSMH Luminaire Photometric Data *
Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH. Data Based on 70 Watt, HPS Clear B-17 Medium Base Lamp (6,300 lumens).

Lighting
Lighting: General Lighting — Area — Architectural
Typical Footcandle Values

Ft. Candles for Iso-Footcandle Lines 70 W High Pressure Sodium

Mtg. Ht. A B C D E F G
6' 5.80 4.80 3.87 2.88 1.94 0.96 0.39

7' 4.22 3.54 2.84 2.14 1.42 0.70 0.29

8' 3.26 2.72 2.17 1.63 1.09 0.54 0.22

10' 2.09 1.73 1.39 1.04 0.70 0.34 0.14

12' 1.45 1.21 0.96 0.72 0.48 0.24 0.10

14' 1.06 0.89 0.71 0.53 0.36 0.18 0.07

Watts Lumens Mult.


35 2,250 .357
50 3,500 .556
100 9,500 1.508
150 16,000 2.540

NOTE: For other HPS, Clear, Med. Base Lamps multiply


all footcandle values as follows:

◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.)
* Additional photometric charts available on request.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1389


© September 2010
Wallmaster 400 HPS/PSMH Luminaires

Horizontal Lamps Suitable for Wet Locations


400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
Lighting

Applications
Lighting: General Lighting — Area — Architectural

• Ideal where illumination over wide areas adjacent to walls is


required. Applications include:
— Walkways
— Parking lots
— Garages
— Building exteriors
— Shopping centers
— Stores
— Restaurants
— Tunnels
— Underpasses
— Loading docks
— Ramps
— Security lighting areas
— Entrances
— Recreational areas
Features
• Enclosed and gasketed for use in outdoor wet locations.
• Specular anodized aluminum reflector provides efficient light
projection.
• High transmittance, non-yellowing borosilicate glass refractor
for superior photometrics.
• Field adjustable bracket permits easy adjustment of beam
angle.
• Quick, easy installation. Back plates permit alignment with
virtually all standard recessed junction boxes.
• Prewired, integrally ballasted. Housing is designed for heavy
duty use and coated with bronze polyester powder to optimize
protection against chipping and fading.
• Stainless steel aircraft cable connects lens assembly to
mounting plate freeing both hands for servicing and installation.
• 3 tapped holes (1/2”/12.7 mm NPS standard) – one on each
side and one on the top. May be used for conduit or optional
photocontrol.
• All ballasts are high power factor, CWA type.
Standard Materials
• Ballast housing: die cast copperfree (4/10 of 1% max.)
aluminum
• Refractor: heat and shock resistant, non-yellowing borosilicate
glass
• Refractor to housing joint: liquid silicone rubber
• Gasket (between lens assembly and mounting plate): neoprene
• Lamp socket: glazed porcelain
Standard Finishes
• Ballast housing: bronze polyester finish
Options
• Stainless steel wire guard to protect fixture.
• Lexan® shields for added protection.
• Photocontrol for automatic ON/OFF operation.
• Fusing to provide overcurrent protection.
Certifications and Compliances
• UL Listed: E85142
• UL Standard:1598
• CSA Certified: LR9349

1390 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Wallmaster 400 HPS/PSMH Luminaires

Horizontal Lamps Suitable for Wet Locations


400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.

Lighting
Lighting: General Lighting — Area — Architectural
Line Weight Lbs./ Catalog
Description Voltage Kgs ➊ Number
175 Watt Metal Halide
CWA Ballast, High Power Factor 120-277 17/7.7 G-WM530P-MT ➋
CWA Ballast, High Power Factor 480 17/7.7 G-WM530P-48 ➋

250 Watt Pulse Start Metal Halide


CWA Ballast, High Power Factor 120-277 24/10.9 G-WM630P-MT ➋
CWA Ballast, High Power Factor 480 24/10.9 G-WM630P-48 ➋
400 Watt Pulse Start Metal Halide
CWA Ballast, High Power Factor 120-277 38/17.2 G-WM730P-MT ➋
CWA Ballast, High Power Factor 480 38/17.2 G-WM730P-48 ➋
250 Watt High Pressure Sodium
CWA Ballast, High Power Factor 120-277 41/18.6 G-WM630L-MT ➋
CWA Ballast, High Power Factor 480 41/18.6 G-WM630L-48 ➋
400 Watt High Pressure Sodium
CWA Ballast, High Power Factor 120-277 45/20.4 G-WM730L-MT ➋
CWA Ballast, High Power Factor 480 45/20.4 G-WM730L-48 ➋

Dimensions

MH PSMH, HS
12.25"/
12-1/4" 7.25"/
7-1/4"
311.2 mm 184.2 mm 17.0"/ 14.0"/
431.8 mm 355.6 mm

9.5"/ 9.5"/
9-1/2"
241.3 mm 241.3 mm

➊ All weights are approximate.


➋ Use supply wire rated 302 °F/150 °C.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1391


© September 2010
Wallmaster 400 HPS/PSMH Luminaire Accessories

Horizontal Lamps Suitable for Wet Locations


400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
Lighting
Lighting: General Lighting — Area — Architectural

Description Weight Lbs./Kgs ➊ Catalog Number


Fuse Kit
2 Amp 0.1/.05 G-FH2
3 Amp 0.1/.05 G-FH3
5 Amp 0.1/.05 G-FH5
6 Amp 0.1/.05 G-FH6
8 Amp 0.1/.05 G-FH8
10 Amp 0.1/.05 G-FH10
Stainless Steel Guard
For use with 175 Watt Metal Halide 1.2/0.54 G-WM5G
For use with 250 – 400 Watt Metal Halide
1.3/0.59 G-WM7G
and High Pressure Sodium

Lexan® Shield
For use with 175 Watt Metal Halide 1.0/0.45 G-WM5VS
For use with 250 – 400 Watt Metal Halide
1.5/0.68 G-WM7VS
and High Pressure Sodium

Photocontrols
120 Volt (1900 VA) 0.3/0.14 G-WMPC120
208-277 Volt (1900 VA) 0.3/0.14 G-WMPC208

480 Volt (1900 VA) 0.3/0.14 G-WMPC480

Replacement Parts
Lens / Cover Assembly for 175 Watt Units 6.5/2.95 G-WM5CA
Lens / Cover Assembly for 250 – 400 Watt Units 11.3/5.13 G-WM7CA
Mogul Base Lampholder 0.5/0.23 G-WMRS

➊ All weights are approximate

1392 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Wallmaster 400 HPS/PSMH Luminaire Photometric Data

Horizontal Lamps Suitable for Wet Locations


400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.

Lighting
Lighting: General Lighting — Area — Architectural
G-WM730P
Lamp: 400 Watt Pulse Start Metal Halide RATIO: LATERAL DISTANCE / MOUNTING HEIGHT

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.


Clear, BT-37 0

Lumens: 34000
Mounting Height: 20 Feet 1
5

400 Watt Metal Halide 2

CONVERSION TABLE 2 1

for different mounting heights .5

15’ 1.78 30’ .44 3

20’ 1.00 35’ .33 .2


4
25’ .64 40’ .25 3 2 1 0 1 2 3

G-WM630P
Lamp: 250 Watt Pulse Start Metal Halide RATIO: LATERAL DISTANCE / MOUNTING HEIGHT

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.


Clear, BT-28 0
Lumens: 19500
Mounting Height: 15 Feet 5
1
2
CONVERSION TABLE
1
for different mounting heights 2
.5
10’ 2.25 20’ .56
15’ 1.00 25’ .36 3
.2

4
3 2 1 0 1 2 3
G-WM530P
Lamp: 175 Watt Pulse Start Metal Halide RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
Coated, BT-28
(in middle position)

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.


1
Lumens: 12000
Mounting Height: 10 Feet 0

CONVERSION TABLE 1
5
for different mounting heights 2
2
8’ 1.56 16’ .39 1
3 .5
10’ 1.00 18’ .30
12’ .83 20’ .25 4 .25

14’ .51
5

3 2 1 0 1 2 3

G-WM730L
Lamp: 400 Watt High Pressure Sodium RATIO: LATERAL
RATIO: LATERAL DISTANCEDISTANCE / MOUNTING
/ MOUNTING HEIGHT HEIGHT
Clear, E18 0
Lumens: 50000
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

1
Mounting Height: 20 Feet
10
1
0
5
CONVERSION TABLE
2
for different mounting heights 1 2 5

15’ 1.78 30’ .44 2 1


2
1
3
20’ 1.00 35’ .33
3 .5 .5
25’ .64 40’ .25
4 .25
4
.2
5 5
3 2 1 0 1 2 3
3 2 1 0 1 2 3

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1393


© September 2010

RATIO: LATERAL DISTANCE / MOUNTING HEIGHT


0
RAT
Wallmaster 400 HPS/MH Luminaires Photometric Data

Horizontal Lamps Suitable for Wet Locations


400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
Lighting
Lighting: General Lighting — Area — Architectural

G-WM630L
Lamp: 250 Watt High
Pressure Sodium
Clear, E-18 RATIO: LATERAL DISTANCE / MOUNTING HEIGHT

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.


0
Lumens: 27500
Mounting Height: 20 Feet
5
1

2
2
1

.5
3

.2
4
3 2 1 0 1 2 3

RATIO: LATERAL DISTANCE / MOUNTING HEIGHT

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.


0
Fusing For Wallmaster™ 400
5
Ballast Amps 1 Fuse Catalog Number
2
High Pressure Sodium (CWA) Pulse Start Metal Halide (CWA) Fuse HPS PSMH
Lamp Watts Volts Rating Start Oper. Rating Start Oper. 2 Qty. Req. 1
(CWA) (CWA)
120 — — — 5A .90 1.78 1 .5 — G-FH5
208 — — — 3A .50 1.08 3 2 — G-FH3
175 W 240 — — — 3A .35 .89 2 .2
— G-FH3
277 — — — 2A .30 .76 4 1 — G-FH2
3 2
480 — — — 2A .25 .50 2 1 0 1
— 2 3
G-FH2
120 8A 2.00 2.50 8A 1.90 2.50 1 G-FH8 G-FH8
208 5A 1.20 1.50 5A 1.10 1.45 2 G-FH5 G-FH5
250 W 240 5A 1.00 1.30 5A .96 1.25 2 G-FH5 G-FH5
277 3A .85 1.10 3A .85 1.10 1 G-FH3 G-FH3
480 3A .40 .65 3A .45 .60 2 G-FH3 G-FH3
120 10A 3.30 3.80 10A 3.50 4.00 1 G-FH10 G-FH10
208 8A 1.80 2.20 6A 2.00 2.30 2 G-FH8 G-FH6
400 W 240 5A 1.60 1.90 5A 1.75 2.00 2 G-FH5 G-FH5
277 5A 1.40 1.70 5A 1.50 1.75 1 G-FH5 G-FH5
480 5A .80 1.00 5A .90 1.00 2 G-FH5 G-FH5

1394 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster Squarelite™ 400 Sharp Cutoff Luminaires
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.

Lighting
Applications

Lighting: General Lighting — Area — Architectural


• Powerful, efficient lighting for areas such as parking lots,
shopping centers, building exteriors, sports areas, security
lighting and industrial process lighting.
• Ideal where controlled light distribution over medium or large
size areas is required. Delivers light only where it is needed with
virtually no glare.
• Enclosed and gasketed, Suitable for use in wet locations.
Features
• A single luminaire efficiently projects light in a rectangular
pattern-the shape of most areas to be lighted. A cluster of four
pole-mounted luminaires casts light in a nearly perfect square.
Ideal for such areas as parking lots, shopping centers and
sports areas.
• Utilizes a specially developed, small, double-ended tubular
lamp in combination with a unique precision reflector. The
design of the reflector together with the precise positioning of Illustrated Features
the arc tube provides exceptionally accurate control of the light
distribution.
• Projects optimum light levels over medium and large size areas
with virtually no wasted light. A single, horizontally mounted 400
Watt luminaire provides 36,350 candlepower at 51 with a sharp
cutoff at 66° (62° at front and 4° at back of luminaire) with a
horizontal cutoff (sideways ) at 101°.
• Sharp cutoff confines light to specific property zones No spilling
of light on neighboring properties.
• Even light distribution at a 4-to-1 spacing-to-pole-height ratio.
• Virtually no glare. The lamp is deeply recessed within the
reflector to eliminate visually uncomfortable glare.
• Compact in size, attractively styled contemporary design,
rugged and dependable. Unique reflector design projects light at wide angle with sharp cutoff.
• A wide range of ballasts and voltages are available for both Projected Area: 1.2 Sq. Ft./0.11 Sq. M.
domestic and export applications.
• Integral ballast.
• Mounting Choice:
(1) Trunnion mount, zinc plated steel trunnion with architectural
bronze polyester finish
(2) Integral slip-fitter mount. Built-in slip-fitter for internal wiring.
Adjustable laterally and vertically, slip-fits 2” or 2-1/2”/50.8 or
63.5 mm pipe. Architectural bronze polyester finish
(3) Davit Mount. Bolts to square pole-topfitter. Up to four
luminaries may be clustered on each pole fitter
Standard Materials
• Reflector: aluminum
• Lens: thermal shock and impact resistant glass With Areamaster Squarelite, a single horizontally mounted
• Gasket: silicone rubber (for low glare) luminaire projects light at a wide angle with sharp
• Housing: aluminum cutoff-ideal for medium and large size areas such as
• Lens door: aluminum parking lots, shopping centers and sports areas.
• Hex head bolts: 4 — 1/4"/6.4 mm dia. captive stainless steel
Standard Finishes
Electrical Specifications
• Reflector: natural finish
• Housing, mounting and lens door: architectural bronze polyester High Pressure Sodium — C.W.A. Ballast Amps — 400 W
finish Line Volts Start Oper. Total Watts
Certifications and Compliances 120 3.30 3.80 465
• UL Listed: E85142 208 1.80 2.20 465
• UL Standard: 1598 240 1.60 1.90 465
• CSA Certified: LR9349 277 1.40 1.70 465
347 1.00 1.32 465
480 0.80 1.00 465

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1395


© September 2010
Areamaster Squarelite™ 400 Sharp Cutoff Luminaires
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.
Lighting
Lighting: General Lighting — Area — Architectural

Description LIne Voltage Catalog Number ➊


Davit Mount
120/208/240/277 G-SC776L-MT-L ➋
Bolts to Square Poletop Filter
(Cat No. G-SCDA) or Wall 480 G-SC776L-48-L
Bracket (Cat. No. G-SWD-1 120/208/240/277 G-SC776L-MT ➋
below.
480 G-SC776L-48
Integral Slip-Fitter Mount
120/208/240/277 G-SC775L-MT-L ➋
Slip-fits on any 2”/50.8 mm or
480 G-SC775L-48-L
2-1/2”/63.5 mm pipe size poletop
tenons.
120/208/240/277 G-SC775L-MT ➋

480 G-SC775L-48
Trunnion Mount
120/208/240/277 G-SC771L-MT-L ➋

May be used with Poletop 480 G-SC771L-48-L


slip-fitter or crossarm accessory 120/208/240/277 G-SC771L-MT ➋

480 G-SC771L-48
Square Poletop Fitter for Davit Mount

Slips onto 2”/50.8 mm poletop tenons.


Accommodates up to four Davit Mount G-SCDA
luminaires.

Wall Bracket for Davit Mount

Secured to wall with four bolts.


G-SWD-1
Davit mount is bolted to this bracket.

Vandal Shield for Luminaire

UV stabilized polycarbonate, with installation


G-AM-6-VS
hardware and instructions.

Photocontrol Receptacle

For NEMA type photocontrol, with installation


G-1PCR
hardware, instructions.

➊ Lamp furnished with fixture on catalog numbers with Suffix -L: HPS tubular 400 W T-7, 46,000 lumens (LU400/T7).
➋ Change the -MT suffix to -TT for tri-tap 120/277/347 V V.

1396 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Areamaster Squarelite™ 400 Sharp Pole Data
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.

Lighting
Lighting: General Lighting — Area — Architectural
Application
• To mount single or multiple luminaires at heights of 20 to 40 4.0"/
feet/ 6.1 to 12.2 meters.
101.6 mm T
Features 4.0"/
101.6 mm
• 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3
or 4 luminaires with appropriate poletop bracket.
• High-strength shafts are made from square steel structural tube 2”/50.8 mm
with minimum yield strength of 46,000 psi. Pipe Size Tenon
• Base plates are of structural quality hot-rolled steel with (2-3/8”/
minimum yield strength of 36,000 psi. Anchor base telescopes 60.5 mm O.D.)
the pole shaft and is welded around top and bottom.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
• Anchor bolts are furnished complete with two hex nuts and
washers, and are of 55,000 psi steel.
• Poles are designed to withstand dead loads and theoretical
dynamic loads developed by sustained winds of 80 mph/128 14.0"/
355.6 mm
kph with an appropriate gust factor. The weights and EPA
include luminaires and/or mounting adapters, and their effective
projected area is considered to be the product of
the actual projected area and the drag coefficient. Pennants,
signs, and similar elements that create additional stress on
poles should not be used without prior factory approval.

Square Steel Poles for Davit Mount Luminaires


Dimensions may vary. Consult your local sales representative for specifications
Mtg. Ht. Bolt Circle Base Thickness Anchor Bolt Max. Proj.
Feet/Meters Shaft Size in/mm in/mm Dia. x Lgth. Area
A Inches/ Millimeters BC T in/mm Sq.Ft./Sq.M. ➊ Catalog Number ➌
4” x 4” x 11Ga./ .75 x 20/
20/6.1 ➋ .75/19.1 9.0/0.84 G-PSSL-20EPX
101.6 x 101.6 x 11Ga 19.1 x 508
4” x 4” x 11Ga. .75 x 20/
25/7.6 ➋ .75/19.1 4.1/0.38 G-PSSL-25EPX
101.6 x 101.6 x 11Ga. 19.1 x 508

5” x 5” x 11Ga. .25 x 20/


30/9.1 ➋ 1.0/25.4 4.2/0.39 G-PSSL-30EPX
127 x 127x 11Ga 25.4 x 508

5” x 5” x 7Ga. 1 x 40/
35/10.7 ➋ 1.0/25.4 6.1/0.57 G-PSSM-35EPX
127 x 127 x 7Ga 25.4 x 1016
6” x 6” x 7Ga. 1 x 40
39/11.9 ➋ 1.0/25.4 7.8/0.72 G-PSSH-39EPX
152.4 x 152.4 x 7Ga. 25.4 x 1016

➊ Calculated for winds of 80 MPH/128 KPH.


➋ Dimensions may vary- Consult your local sales representative for specifications.
➌ Square steel poles are furnished with anchor bolts and nuts, and 2-3/8”/60.5 mm O.D. x 4”/101.6 mm tenon, finished with bronzetone enamel and
cardboard wrapped. Touch-up paint furnished with every shipment.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1397


© September 2010
Areamaster Squarelite™ 400 Sharp Cutoff Luminaire Photometric Data
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.
Photometric Number TSC2001-S2 Sharp Cutoff 400 W HPS Luminaire G-SC776L-MT. (HPS 400 W LU400/T7, 46,000 lumens).
Lighting
Lighting: General Lighting — Area — Architectural

This report has been prepared in accordance with IES guides on testing
procedures. It is representative of luminaires tested under standardized and
stabilized laboratory conditions. Various operating factors can cause differences
between laboratory data and actual field performance.

Distance (ft) Mounting Height (Feet)


Ahead/Behind
Footcandle 30 40 50 60
165 — — .01 .02

Distance in terms of mounting height ◊


160 — — .01 .03
155 — — .01 .03
150 — — .02 .04
145 — — .02 .04
140 — .01 .03 .06
135 — .01 .03 .09
130 — .01 .04 .14
125 — .02 .05 .20
120 — .03 .06 .27
115 — .04 .10 .35
110 .01 .05 .17 .46
105 .01 .06 .26 .60
100 .02 .08 .38 .77
95 .03 .10 .54 .93
Distance in terms of mounting height ◊
90 .05 .21 .74 1.13
85 .07 .37 1.00 1.37
80 .10 .60 1.29 1.66
75 .14 .91 1.62 2.02
70 .23 1.35 2.05 2.16
65 .55 1.91 2.69 2.21
60 1.06 2.53 9.07 2.21
55 1.85 3.39 3.17 2.18 400W HPS
50 3.08 4.55 3.19 2.34 Ft. Candles for Iso-Footcandle Lines
Mtg.
45 4.51 4.93 3.16 2.24 Ht. A B C D E F G H
40 6.64 4.98 3.23 2.31 20 29.03 20.21 19.19 8.07 2.39 .39 .17 .04
35 8.65 4.98 3.18 2.57 25 18.58 12.91 12.28 5.16 1.53 .25 .11 .04
30 8.85 5.04 3.63 2.85 30 12.90 8.98 8.53 3.59 1.06 .17 .08 .03
25 8.95 5.49 4.10 3.16 35 9.48 6.60 6.27 2.63 .78 .13 .06 .02
20 9.25 6.41 4.64 3.43 40 7.26 5.05 4.80 2.02 .60 .10 .04 .02
15 11.4 7.47 4.95 3.41 45 5.73 4.00 3.79 1.59 .47 .08 .03 .01
10 13.7 7.67 4.83 3.18
5 12.7 6.53 3.93 2.60
0 6.58 3.70 2.37 1.65
-5 1.15 .81 .58 .48
-10 .60 .40 .33 .29
-15 .77 .31 .23 .18
-20 1.13 .43 .21 .15
-25 1.11 .59 .26 .15
-30 .85 .70 .35 .19

◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.)
* Additional photometric charts available on request.

1398 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Round Tapered Steel Poles

Applications
• To mount single or multiple luminaires to heights from 20 to 39
feet/6.1 to 11.9 meters.
Features 4.0"/
101.6 mm

Lighting
• 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3,
or 4 luminaires with appropriate pole-top mounting bracket.
• Shafts are tapered, one-section 2"/50.8 mm
design of 11 gauge commercial quality steel with a minimum Pipe Size Tenon
(2-3/8"/60.5 mm O.D)
yield strength of 55,000 psi after fabrication.
• Base plates are of structural quality hot-rolled steel with
guaranteed minimum yield strength of 36,000 psi.
• A 4” x 6-1/2”/101.6 x 165.1 mm reinforced handhole with

Lighting: General Lighting — Area — Poles and Hangers


cover and grounding lug 14”/55.6 mm above the pole base is
standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX.
• For galvanized finish add -GAL.

14.0"/
355.6 mm

Dimensions may vary. Consult your local sales representative for specifications
Mounting Base Tube
Height Base Size Bolt Circle Thickness Bolt Proj. Diameter Anchor Bolt Max.
Ft/M In/mm In/mm In/mm In/mm In/mm Dia. x Lgth. Proj Area Catalog
A Shaft Size ➋ S➊ BC T➊ P➊ D In/mm Sq.Ft./Sq.M.➌ Number ➍
6.5 x 3.7 x 20’/ 1 x 40/
20/6.1 10.0/254.0 ➊ 1.0/25.4 2.25/57.2 6.5/165.1 18.7/1.74 G-PRTH-20
165.1 x 94.0 x 6.1 25.4 x 1016
7.0 x 3.5 x 25’/ 1 x 40
25/7.6 10.5/266.7 ➊ 1.0/25.4 2.25/57.2 7.0/177.8 14.4/1.34 G-PRTH-25
177.8 x 88.9 x 7.6 25.4 x 1016
8.0 x 3.8 x 30’/ 1 x 40
30/9.1 11.5/292.1 ➊ 1.0/25.4 2.25/57.2 8.0/203.2 14.5/1.35 G-PRTH-30
203.2 x 96.5 x 9.1 25.4 x 1016
8.5 x 3.6 x 35’/ 1 x 40
35/10.7 12.0/304.8 ➊ 1.0/25.4 2.25/57.2 8.5/215.9 12.6/1.17 G-PRTH-35
215.9 x 91.4 x 10.7 25.4 x 1016
9.0 x 3.5 x 39’/ 1 x 40
39/11.9 13.0/330.2 ➊ 1.0/25.4 2.25/57.2 9.0/228.6 11.7/1.09 G-PRTH-39
228.6 x 88.9 x 11.9 25.4 x 1016
➊ Dimensions may vary—Consult your local sales representative for specifications.
➋ Shaft bottom (In. Dia./MM. Dia) x shaft top (In. Dia./MM.Dia.) x shaft length to tenon.
➌ Calculated for winds of 100 MPH/160 KPH.
➍ Anchor bolts and nuts are furnished.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1399


© September 2010
Hinged Steel Poles

Applications
• To mount single or multiple luminaires to heights from 20 to 35
2"/50.8 mm Pipe Size Tenon
feet/6.1 to 9.1 meters. Hinged design allows easy servicing of (2-3/8"/60.5 mm)
luminaires at shoulder height. 4.0"/
101.6
Lighting

mm
Features
• Shafts are structural steel with a minimum yield strength of
46,000 psi.
• Heavy duty hinge assembly secures upper section to lower
section with high strength 3/4”/19.05 mm Dia. bolt. A flexible
protective channel is provided to protect wires when pole is
lowered.
• Pole counter-balance is designed to offset weight of luminaires
Lighting: General Lighting — Area — Poles and Hangers

and is made from steel with minimum yield strength of 36,000


psi.
• Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 50,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options 14.0"/
355.6
mm
• For bronze powder coat finish (to match Appleton fixtures) add
suffix -EPX. For galvanized finish add -GAL.
• An optional lowering winch is available and recommended for
easy one-man operation of hinged poles. (Only one lowering
winch per installation is required because winch assembly
mounts from pole to pole and dismounts for easy storage.)
Lowering winch is furnished with mounting hardware, 25 Accessory: GLW –
feet/7.62 m of 3/16”/4.8 mm galvanized wire rope and safety Lowering Device (Winch)
snap hook.

Dimensions may vary. Consult your local sales representative for specifications
Mounting Shaft Size Base
Height (In.Sq./mm.Sq. x Ga.) Base Size Bolt Circle Thickness Bolt Proj. Anchor Bolt Max. Loading
ft/m In. Sq/mm. Sq In/mm In/mm In/mm Dia. x Lgth. Proj Area Weight Catalog
A F E S➊ BC T P In/mm Sq.Ft./Sq.M. ➌ lbs/kgs Number ➋
.75 x 28/
20/6.1 4/2580.6 x 7 4/2580.6 x 11 10.0/6451.6 ➊ .75/19.1 2.0/50.8 9.3/0.86 230/104.3 G-PHSM-20
19.1 x 711.2
1.0 x 40/
20/6.1 5/3225.8 x 7 5/3225.8 x 11 11.5/7419.3 ➊ 1.0/25.4 2.25/57.2 15.2/1.4 350/158.8 G-PHSH-20
25.4 x 1016
.75 x 28/
24/7.32 4/2580.6 x 7 4/2580.6 x 11 10.0/6451.6. ➊ .75/19.1 2.0/50.8 6.1/0.57 170/77.1 G-PHSM-24
19.1 x 711.2
1.0 x 40/
24/7.32 6/3871.0 x 7 6/3871.0 x 11 12.0/7741.9 ➊ 1.0/25.4 2.25/57.2 14.3/1.33 280/127.0 G-PHSH-24
25.4 x 1016
.75 x 28/
30/9.14 4/2580.6 x 7 4/2580.6 x 11 10.0/6541.6 ➊ .75/19.1 2.0/50.8 2.9/0.27 150/68.0 G-PHSM-30
19.1 x 711.2
1.0 x 40/
30/9.14 6/3871.0 x 7 6/3871.0 x 11 12.0/7741.9 ➊ 1.0/25.4 2.25/57.2 10.8/1.00 240/108.9 G-PHSH-30
25.4 x 1016
1.0 x 40/
35/10.67 6/3871.0 x 7 6/3871.0 x 11 12.0/7741.9 ➊ 1.0/25.4 2.25/57.2 3.6/0.33 180/81.6 G-PHSH-35
25.4 x 1016

➊ Dimensions may vary—Consult your local sales representative for specifications.


➋ Anchor bolts and nuts are furnished. For accessory lowering winch, specify Cat. No. GLW.
➌ Calculated for winds of 100 MPH/160 KPH.

1400 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Square Tapered Steel Poles

Applications
• To mount single or multiple luminaires to heights from 20 to 39
feet/6.1 to 11.9 meters.
Features 4.0"/

Lighting
101.6 mm
• 2”/0.61 mm pipe size tenon accepts a single luminaire or 2, 3, 2"/50.8 mm
Pipe Size Tenon
or 4 luminaires with appropriate pole-top mounting bracket. (2-3/8"/60.5 mm O.D)
• High strength shafts have a uniform taper and are made from
11 gauge commercial quality hot rolled steel.
• Base plates are of structural quality hot rolled steel with
minimum yield strength of 36,000 psi.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.

Lighting: General Lighting — Area — Poles and Hangers


• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL.

14.0"/
355.6 mm

Dimensions may vary. Consult your local sales representative for specifications
Mounting Base
Height Base Size Bolt Circle Thickness Bolt Proj. Anchor Bolt
Ft/M Shaft Size ➊ In/mm In/mm In/mm In/mm Dia. x Lgth. Max. Proj Area Catalog
A Sq.In./Sq.MM. x Ft/M S➋ BC T➋ P➋ In/mm Sq.Ft/Sq.M ➌ Number ➍
5.25 x 3.25 x 20’/ 1 x 40/
20/6.1 10.5/266.7 ➋ 1.0/25.4 2.25/57.2 9.4/0.87 G-PSTH-20
3387 x 2097 x 6.1 25.4 x 1016.0
6.25 x 3.85 x 24’/ 1 x 40/
24/7.3 13.0/330.2 ➋ 1.0/25.4 2.25/57.2 8.9/0.83 G-PSTH-24
4032 x 2484 x 12.2 25.4 x 1016.0
6.65 x 3.25 x 30’/ 1 x 40/
30/9.1 12.0/304.8 ➋ 1.0/25.4 2.25/57.2 5.8/0.54 G-PSTH-30
4290 x 2097 x 9.1 25.4 x 1016.0
6.25 x 3.25 x 35’/ 1 x 40/
35/10.7 13.0/330.2 ➋ 1.0/25.4 2.25/57.2 4.4/0.41 G-PSTH-35
4032 x 2097 x 10.7 25.4 x 1016.0
7.15 x 3.25 x 39’ 1 x 40/
39/11.9 13.0/330.2 ➋ 1.0/25.4 2.50/63.5 3.8/0.35 G-PSTH-39
4613 x 2097 x 11.9 25.4 x 1016.0

➊ Shaft bottom (Sq. In.) x shaft top (Sq. In.) x shaft length to tenon.
➋ Dimensions may vary—Consult your local sales representative for specifications.
➌ Calculated for winds of 100 MPH.
➍ Anchor bolts and nuts are furnished.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1401


© September 2010
Square Steel Poles

Applications
• To mount single or multiple luminaires to heights from 14 to 30
feet/4.3 to 9.1 meters.
Features 4.0"/
101.6
Lighting

mm 2"/50.8 mm Pipe Size Tenon


• 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3, (2-3/8"/60.5 mm)
or 4 luminaires with appropriate pole-top mounting bracket.
• High strength shafts are made from square steel structural tube
with minimum yield strength of 46,000 psi.
• Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
Lighting: General Lighting — Area — Poles and Hangers

• Anchor bolts are furnished complete with nuts and washers,


and are of 55,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL.
14.0"/
355.6
mm

Dimensions may vary. Consult your local sales representative for specifications
Mounting Base
Height Base Size Bolt Circle Thickness Bolt Proj. Anchor Bolt
Ft/M Shaft Size ➊ In/mm In/mm In/mm In/mm Dia. x Lgth. Max. Proj Area Catalog
A In/mm S➋ BC T➋ P➋ In/mm Sq.Ft./Sq.M. ➌ Number ➍
4” x 4” x 11Ga./ .75 x 20/
14/4.3 8.0/203.2 ➋ .75/19.1 2.00/50.8 10.9/1.01 G-PSSM-14
101.6 x 101.6 x 11Ga. 19.1 x 508.0
4” x 4” x 7Ga./ .75 x 20/
14/4.3 8.0/203.2 ➋ .75/19.1 2.00/50.8 14.4/1.34 G-PSSH-14
101.6 x 101.6 x 11Ga. 19.1 x 508.0
4” x 4” x 11Ga./ .75 x 20/
17/5.2 8.0/203.2 ➋ .75/19.1 2.00/50.8 6.9/0.64 G-PSSM-17
101.6 x 101.6 x 11Ga. 19.1 x 508.0
4” x 4” x 7Ga./ .75 x 20/
17/5.2 8.0/203.2 ➋ .75/19.1 2.00/50.8 11.9/1.11 G-PSSH-17
101.6 x 101.6 x 7Ga. 19.1 x 508.0
4” x 4” x 7Ga./ .75 x 20/
20/6.1 8.0/203.2 ➋ .75/19.1 2.00/50.8 10.1/0.94 G-PSSM-20
101.6 x 101.6 x 7Ga. 19.1 x 508.0
5” x 5” x 7Ga./ 1 x 40/
20/6.1 11/279.4 ➋ 1.0/25.4 2.25/57.2 17.2/1.60 G-PSSH-20
127.0 x 127.0 x 7Ga. 25.4 x 1016
5” x 5” x 7Ga./ 1 x 40/
24/7.3 11/279.4 ➋ 1.0/25.4 2.25/57.2 11.9/1.11 G-PSSM-24
127.0 x 127.0 x 11Ga. 25.4 x 1016
6” x 6” x 7Ga./ 1 x 40/
24/7.3 12.0/304.8 ➋ 1.0/25.4 2.25/57.2 18.8/1.75 G-PSSH-24
152.4 x 152.4 x 7Ga. 25.4 x 1016
5” x 5” x 7Ga./ 1 x 40/
30/9.1 11/279.4 ➋ 1.0/25.4 2.25/57.2 6.9/0.64 G-PSSM-30
127.0 x 127.0 x 7Ga. 25.4 x 1016
6” x 6” x 7Ga./ 1 x 40/
30/9.1 12.0/304.8 ➋ 1.0/25.4 2.25/57.2 11.7/1.09 G-PSSH-30
152.4 x 152.4 x 7Ga. 25.4 x 1016
➊ Shaft bottom (Sq. In.) x shaft top (Sq. In.) x shaft length to tenon.
➋ Dimensions may vary—Consult your local sales representative for specifications.
➌ Calculated for winds of 100 MPH.
➍ Anchor bolts and nuts are furnished.

1402 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles

Metal Pole Brackets

Lighting
Lighting: General Lighting — Area — Poles and Hangers
Wood Pole Brackets

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1403


© September 2010
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles

Poletop Brackets for Metal Poles — Dimensions may vary. Consult your local sales representative for specifications
Floodlight mounting brackets for installation of 2 to 4 floodlights atop metal poles are manufactured from high-strength steel tube, and
slip-fit onto 2”/50.8 mm pipe size poletop tenons. Furnished with 3 locking setscrews and red oxide prime coat finish. Bracket tenon is
2”/50.8 mm pipe size (2-3/8”/60.5 mm O.D.).
Lighting

Dimensions Description Catalog Number

17.0"/ 17.0"/
431.8 mm 431.8 mm

10.0"/
254.0 mm
Poletop Bracket for Two Luminaires G-PB-2
Lighting: General Lighting — Area — Poles and Hangers

1.0"/25.4 mm
5.0"/
127.0 mm Slip-Fitter for 2"/50.8 mm
(3) 3/8"/9.7 mm x 5/8"/16.0 mm Std. Pipe
Setscrews at 120 °

17.0"/ 17.0"/
431.8 mm 431.8 mm

2.0"/ 20.0"/
50.8 mm 508.0 mm
Std. Pipe
10.0"/ Poletop Bracket for Three Luminaires G-PB-3
254.0 mm

1.0"/25.4 mm
5.0"/
127.0 mm Slip-Fitter for 2"/50.8 mm
(3) 3/8"/9.7 mm x 5/8"/16.0 mm Std. Pipe
Setscrews at 120 °

Poletop Bracket for Three Luminaires (120° apart) G-PB-3-120


17.0"/
431.8 mm R.

30.0"/ 30.0"/ 30.0"/


762.0 mm 762.0 mm 762.0 mm
1-1/8"/ 2.0"/
28.7 mm 50.8 mm
10.0"/ Dia. Hole for
254.0 mm wiring Std. Pipe
Poletop Bracket for Four Luminaires (in line) G-PB-14
1.0"/25.4 mm
5.0"/
127.0 mm
Slip-Fitter for 2"/50.8 mm
(3) 3/8"/9.7 mm x 5/8"/16.0 mm Std. Pipe
Setscrews at 120 °

34.0"/

17.0"/ 2.0"/
863.6 mm
Poletop Bracket for Four Luminaires G-PB-4
50.8 mm Removable
431.8 mm R Cap
10.0"/ Std. Pipe
254.0 mm
5.0"/ 0.5"/12.7 mm
127.0 mm

Slip-Fitter for 2"/50.8 mm (3) 3/8"/9.7mm x 5/8"/16.0 mm


Std. Pipe Setscrews at 120 °

1404 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles

Poletop Reducers
Made from high strength steel tubing, complete with 3 locking setscrews and with red-oxide prime finish.
Dimensions — May vary. Consult your local sales
representative for specifications

Lighting
Poletop Pipe Size Reduction
Catalog Number 2"/50.8 mm Pipe Size
In/mm (2-3/8"/60.5 mm O.D.)
2-1/2 to 2/63.5 to 50.8 G-PR-2-1/2
3 to 2/76.2 to 50.8 G-PR-3
4.0"/
3-1/2 to 2/88.9 to 50.8 G-PR-3-1/2 101.6 mm
8.0"/
4 to 2/101.6 to 50.8 G-PR-4 203.2 mm

Lighting: General Lighting — Area — Poles and Hangers


4.0"/
101.6 mm
5 to 2/127 to 50.8 G-PR-5

Lite Mount Bars for 4, 8, or 12 Quartzlite or Areamaster Jr. Floodlights


Bars have 11 gauge steel body and 12 gauge steel cover. Two styles: to mount on 2”/50.8 mm pipe size poletop tenon, or on wood poles
using thru-bolts. Welded construction, with 3/4”/19.1 mm N.P.S. tapped hubs. Rain-tight, with red-oxide prime finish.

Dimensions — May vary. Consult your local sales


representative for specifications
Number of
Fixtures Length A Dim. B Dim C Dim. D For Metal Poles
4 28 – 25 1-1/2
8 60 17 24-1/2 1-1/4
12 96 17 25 1-1/2 4.0"/
101.6 mm

Dimensions For Mounting Quartzlites or Areamaster Jr.


Bar Assembly for 2"/50.8 mm 2"x4"/50.8 x 101.6 mm
Number of Fixtures For Catalog Number Pipe Size Tenon Access Door
(3) Setscrews
Mounting Metal Pole Wood Pole
NPT Light Mount Type
4 Fixtures G-PQM-4T G-PQM-4W
8 Fixtures G-PQM-8T G-PQM-8W
12 Fixtures G-PQM-12T G-PQM-12W
For Wood Poles

NPT Light Mount Type

11.0"/
279.4 mm

2"x4"/
50.8 x 101.6 mm 11/16"/17.5 mm Dia. Holes
Access Door

4.0"/
101.6 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1405


© September 2010
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles

Dimensions may vary. Consult your local sales representative for specifications

Description Catalog Number


5.0"/
127.0 mm
Wood Pole or Wall Mounting Bracket
Lighting

For Floodlights with 2”/50.8 mm Slip-Fitter, or will mount G-PB


Series brackets with floodlights.
• Complete with two 13”/330.2 mm-long bolts, washers, and
nuts. G-PWB-1
8-1/2"/
215.9 mm • Red oxide prime coat finish.
Lighting: General Lighting — Area — Poles and Hangers

8.0"/
2"/50.8 mm
Wood Pole Clamp Brackets
203.2 mm
Pipe
• Pole clamping floodlight mounting brackets constructed of
7-1/2"/ 2”/50.8 mm steel pipe.
190.5 mm
• Furnished complete with clamping bolts and nuts.
• Has red oxide primer coat finish.
G-PCB-1 • For 1 to 3 floodlights—Fits 6”/152.4 mm to 9”/228.6 mm poles.
• For 4 floodlights—Fits 9”/228.6 mm to 12”/304.8 mm poles.

1 Arm G-PCB-1

G-PCB-2
2 Arm G-PCB-2

3 Arm G-PCB-3
G-PCB-3

4 Arm G-PCB-4

G-PCB-4
6"/152.4 mm Channel 9/16"/0.56 mm Dia. Wood Pole Crossarm Lite Mount Bracket
@ 8.2 lbs/3.7 kgs holes for floodlight mounting
Mounting arm made of rugged angular steel stock with
1/4” supporting struts. Has hot-dipped galvanized finish.
6.0"/
152.4 mm
24.0"/
609.6 mm
24.0"/
609.6 mm
24.0"/
609.6 mm
6.0"/
152.4 mm Furnished with all nuts and bolts to assemble and install
bracket to wood pole.
2 holes, 7/8"/
22.4 mm Dia.
1-1/2"/ (3/4"/19.1 mm Dia.
38.1 mm thru-bolts furnished)

9.0"/228.6 mm 12.0"/304.8 mm

4" x 3"x 1/4"/


101.6 x 76.2 x 6.4 mm 4-Lite G-PCAB-4
Angle

1406 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
AHG and UNJ Flexible Fixture Hangers
Malleable Iron. Ball Type.:15° Swing. Cushion Type: 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
• AHG cushion hangers are enclosed and gasketed—ideal where
dust and dampness are present.
Features
• All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
• AHG hangers
— Enclosed and gasketed. AHG5050 UNJ-50
— Neoprene diaphragm keeps moisture and dirt out of system.
— Cushion type permits 8° swing from vertical.
• UNJ hangers Illustrated Features
— Economical general purpose hanger.

Lighting
— Permits 15° swing.
Standard Materials
• AHG fixture hangers: malleable iron
• UNJ fixture hangers: malleable iron and steel
Standard Finishes
• AHG: triple-coat—(1) zinc electroplate, (2) chromate, and (3)
epoxy powder coat

Lighting: Flexible Fixture Hangers — Ordinary Location


• UNJ: malleable iron and steel parts, zinc electroplate and clear
chromate
Certifications and Compliances
• CSA Certified: 065180 (UNJ)
• UL Listed: E109438 (AWG)

Fixture Stem Male Nipple Length A Support Weight Catalog


Size (Inches) Size (Inches) in/mm (lbs/kg) Number
AHG — Fixture Hangers — Cushion Type — Enclosed and Gasketed — Cushions 40 lbs./18.0 kg.
1/2 1/2 3.19/81.0 AHG5050
1/2 3/4 3.19/81.0 40/18 AHG7550
A 3/4 3/4 3.19/81.0 AHG7575

Cushion
UNJ — Fixture Hangers — Malleable Iron and Steel — Ball Type

1/2 1/2 4.00/101.6 120/54 UNJ-50


3/4 3/4 4.00/101.6 UNJ-75
A

Ball

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1407


© September 2010
AL Ball and Cushion Flexible Fixture Hangers
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.

Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
• Functions as combination conduit outlet box and hanger.
Features
• Protects fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration. ALA — Ball Hanger ALC — Ball Hanger
• Dual function—conduit outlet box and fixture hanger.
• Choice of ball or cushion type.
• Swivel joint construction—allows 20° swing from vertical.
• Cushion style, with conical spring, supports up to 120 lbs/54 kg.
• Cushion type has setscrew for locking fixture stem.
• Fixture and hanger stem can be wired at work bench.
• Connection block available for convenient wiring of fixture leads.
Lighting

Standard Materials
• Malleable iron with steel cover
Standard Finishes
• Malleable iron parts: triple-coat—(1) zinc electroplate,
(2) chromate, and (3) epoxy powder coat
• Steel parts: zinc electroplate ALL — Cushion Hanger ALT — Cushion Hanger
Certifications and Compliances
Lighting: Flexible Fixture Hangers — Ordinary Location

• UL Listed: E109438

Illustrated Features

1408 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
AL Ball and Cushion Flexible Fixture Hangers
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.

Conduit Size Fixture Stem Size Support Weight Catalog


(Inches) (Inches) (lbs/kg) Number
ALA — Ball Hanger
1/2 1/2 ALA50-B
250/112.5
3/4 1/2 ALA7550-B
3/4 3/4 250/112.5 ALA75-B

ALA — Cushion Hanger — Furnished with a 3/4” to 1/2 reducer for 1/2” stems
1/2 3/4 or 1/2 ALA50-12
3 to 12/1.4 to 5.4
3/4 3/4 or 1/2 ALA7575-12
1/2 3/4 or 1/2 ALA50-48
12 to 48/5.4 to 21.6

Lighting
3/4 3/4 or 1/2 ALA7575-48
1/2 3/4 or 1/2 ALA50-120
48 to 120/21.6 to 54.0
3/4 3/4 or 1/2 ALA7575-120

ALC — Ball Hanger

Lighting: Flexible Fixture Hangers — Ordinary Location


1/2 1/2 ALC50-B
3/4 1/2 250/112.5 ALC7550-B
1 1/2 ALC1050-B
3/4 3/4 ALC75-B
250/112.5
1 3/4 ALC1075-B
ALC — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1/2 3/4 or 1/2 ALC50-12
3/4 3/4 or 1/2 3 to 12/1.4 to 5.4 ALC7575-12
1 3/4 or 1/2 ALC1075-12
1/2 3/4 or 1/2 ALC50-48
3/4 3/4 or 1/2 12 to 48/5.4 to 21.6 ALC7575-48
1 3/4 or 1/2 ALC1075-48
1/2 3/4 or 1/2 ALC50-120
3/4 3/4 or 1/2 48 to 120/21.6 to 54.0 ALC7575-120
1 3/4 or 1/2 ALC1075-120

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1409


© September 2010
AL Ball and Cushion Flexible Fixture Hangers
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.

Conduit Size Fixture Stem Size Support Weight Catalog


(Inches) (Inches) (lbs/kg) Number
ALL — Ball Hanger
1/2 1/2 ALL50-B
250/112.5
3/4 1/2 ALL7550-B
3/4 3/4 250/112.5 ALL75-B

ALL — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1/2 3/4 or 1/2 ALL50-12
3 to 12/1.4 to 5.4
3/4 3/4 or 1/2 ALL7575-12
Lighting

1/2 3/4 or 1/2 ALL50-48


12 to 48/5.4 to 21.6
3/4 3/4 or 1/2 ALL7575-48
1/2 3/4 or 1/2 ALL50-120
48 to 120/21.6 to 54
3/4 3/4 or 1/2 ALL7575-120
Lighting: Flexible Fixture Hangers — Ordinary Location

ALT — Ball Hanger


1/2 1/2 ALT50-B
3/4 1/2 250/112.5 ALT7550-B
1 1/2 ALT1050-B
3/4 3/4 ALT75-B
250/112.5
1 3/4 ALT1075-B

ALT — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1/2 3/4 or 1/2 ALT50-12
3/4 3/4 or 1/2 3 to 12/1.4 to 5.4 ALT7575-12
1 3/4 or 1/2 ALT1075-12
1/2 3/4 or 1/2 ALT50-48
3/4 3/4 or 1/2 12 to 48/5.4 to 21.6 ALT7575-48
1 3/4 or 1/2 ALT1075-48
1/2 3/4 or 1/2 ALT50-120
3/4 3/4 or 1/2 48 to 120/21.6 to 54 ALT7575-120
1 3/4 or 1/2 ALT1075-120

1410 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
AL Flexible Fixture Hanger Parts and Dimensions
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Size Support Weight Catalog


(Inches) (lbs/kg) Number
AL — Hanger Bodies
ALA 1/2 ALA50
3/4 ALA75

ALC 1/2 ALC50


3/4 ALC75
1 ALC100
ALL 1/2 ALL50
3/4 ALL75

Lighting
ALT 1/2 ALT50
3/4 ALT75
1 ALT100

AL — Ball Fixture Stem

Lighting: Flexible Fixture Hangers — Ordinary Location


1/2 BJ50
3/4 250/112.5 BJ75

AL — Cushion Fixture Stems


Fixture stem tapped for 3/4”; 3/4” to 1/2" reducer furnished for 1/2” stems. With setscrew for locking fixture stem.
3/4 or 1/2 3-12 / 1.4-5.4 CJC75-12
3/4 or 1/2 12-48 / 5.4-21.6 CJC75-48

3/4 or 1/2 48-120 / 21.6-54.0 CJC75-120

AL — Porcelain Connection Block


2 Wire, 20 Amp, 277 Volt
Maximum Wire Size
CB202
Two No. 10 AWG Large Terminal
Two No. 14 AWG Small Terminal

AL Fixture Hanger Dimensions


Dimensions in Inches/Millimeters
Top View 2.0"/
50.8 mm Conduit Trade
.88"/
22.4 mm
Size A B

1.81"/ 1/2” 0.56/4.2 0.69/17.5


46.0 mm
.25"/6.4 mm Dia.
.25"/
.88"/ 6.4 mm 3/4” 0.69/17.5 0.69/17.5
22.4 mm
Front View
Cushion Stem 3.00"/
76.2 mm
1” 0.88/22.4 0.81/20.6
4.13"/
104.9 mm
7.38"/
187.5 mm

4.00"/ Side View


101.6 mm Ball Stem

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1411


© September 2010
JB and GS Flexible Fixture Hangers
Malleable Iron. Ball Type, 15° Swing; Cushion Type, 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
• JB, GS and AHG cushion hangers are enclosed and gasketed—
ideal where dust and dampness are present.
• JB and GS hangers designed for use with JB and GS boxes.
Features
• All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are JBK-50-BS JBK-50-CS
subjected to vibration.
• JB and GS hangers
— Mount directly to JB and GS cast conduit outlet boxes.
— Choice of ball or cushion type.
— Ball type permits 15° swing, cushion type 8° swing from
vertical
Lighting

— Cushion type is enclosed and gasketed.


Standard Materials
• Malleable iron
Standard Finishes
• GS: triple-coat—(1) zinc electroplate, (2) chromate, and (3)
epoxy powder coat GSK-50-20B GSK-50-20C
• JB series support: zinc electroplate and clear chromate
Lighting: Flexible Fixture Hangers — Ordinary Location

Certifications and Compliances


• JB and GS cushion type hangers suitable for classified location
use in Class I, Division 2 areas, if installed in compliance with
NEC 501-9(b)
• CSA Certified: 065180
• UL Listed: E109438

Illustrated Features

Mercmaster HID Lighting Fixture

1412 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
JB and GS Flexible Fixture Hangers
Malleable Iron. Ball Type, 15° Swing; Cushion Type, 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Fixture Stem Male Nipple Length A Support Weight Catalog


Size (Inches) Size (Inches) in/mm (lbs/kg) Number
JB—Fixture Hanger Covers — For use with JBX, JBDX and JBLX bodies — Furnished with gasket and screws
Ball Type
1/2 2.56/65.0 250/113 JBK-50-BS
A
3/4 2.56/65.0 . JBK-75-BS

Cushion Type
Enclosed and gasketed. Cushions 40 lbs./18.0 kg.
A
1/2 1.63/41.4 40/18 JBK-50-CS
3/4 1.63/41.4 JBK-75-CS

Lighting
GS—Fixture Hanger Covers (Form 20) — For use with GS and GSU bodies — Furnished with gasket and screws
Ball Type
1/2 3.00/76.2 250/113 GSK-50-20B
A 3/4 3.25/82.6 GSK-75-20B

Lighting: Flexible Fixture Hangers — Ordinary Location


Cushion Type
Enclosed and gasketed. Cushions 40 lbs./18.0 kg.
A
1/2 2.00/50.8 40/18 GSK-50-20C
3/4 2.00/50.8 GSK-75-20C

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1413


© September 2010
SSH Flexible Fixture Hangers
Heavy Duty Outlet Box Swivel. Ball Joint Swivel Permits 20° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
• SSH heavy duty swivel hangers for mounting to outlet and
concrete boxes.
Features
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Heavy duty—support fixtures up to 50 lbs/22.7 kg.
• Steel plate serves as cover for outlet or concrete box.
• Ball type swivel joint permits 20°swing from vertical.
Standard Materials
• Malleable iron and steel 11360 11362
Lighting

Standard Finishes
• Malleable iron and steel parts: zinc electroplate and clear
chromate
Certifications and Compliances
• CSA Certified: 065180
• UL Listed: E2527
• UL Standard: 514A
Lighting: Flexible Fixture Hangers — Ordinary Location

Illustrated Features

Industrial lighting installations often employ the


use of extra heavy fixtures requiring a properly
anchored swivel attachment, assuring positive
safety to carry the necessary weight. In the Type
“SSH” Safety Swivel Hanger, the weight of the
entire suspended unit is borne by a fixture stud
instead of relying upon the screws and screw
ears of the box or ring for support. The “SSH”
hanger is furnished with a steel plate to serve
as a cover for the 4” Concrete, Octagonal, and
4-11/16” Square boxes.
Cat. No. 11360 Safety Swivel Hanger Cat. No. 11362 Safety Swivel Hanger
installed in OCR3-1/2 Concrete Box installed in a 4-11/16” Square Box
with OCP3/8 Plate shown with NBFS-38 (not included)

1414 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
SSH Flexible Fixture Hangers
Heavy Duty Outlet Box Swivel. Ball Joint Swivel Permits 20° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Fixture Stem Size Fixture Stud Size Length A Support Weight Catalog
(Inches) (Inches) in/mm (lbs/kg) Number
Concrete Box — Safety Swivel Hanger — For Concrete Box 2-1/2” to 4” Deep

1/2 3/8 2.19/55.6 50/22.5 11360


A

Octagonal Box — Safety Swivel Hanger — For 4” Octagonal Box 1-1/2” or 2-1/8” Deep

Lighting
1/2 3/8 2.19/55.6 50/22.5 11355
A

Lighting: Flexible Fixture Hangers — Ordinary Location


Square Box — Safety Swivel Hanger — For 4-11/16” Square Box 1-1/2” or 2-1/8” Deep

1/2 3/8 2.19/55.6 50/22.5 11362


A

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1415


© September 2010
SHC Flexible Fixture Hangers
Outlet Box Mounted Series
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
• SHC fixture hanger covers for mounting to 3-1/4” and 4”
octagonal boxes and 4” square boxes.
Features
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration. 8438R 8458R
• Ball type swivel joint permits 20° swing from vertical.
• Support fixtures with a maximum weight of 50 lbs/22.7 kg.
Standard Materials
• Steel and malleable iron
Standard Finishes Illustrated Features
Lighting

• Malleable iron and steel parts: zinc electroplate and clear


chromate
Ball Type Swivel
Certifications and Compliances Fixture Hanger
• CSA Certified: 065180 Covers shown with
• UL Listed: E2527 octagonal and with
• UL Standard: 514A
square stamped steel
Related Products
Lighting: Flexible Fixture Hangers — Ordinary Location

outlet boxes.
• For steel boxes, see Commercial Products section.

Fixture Stem Size Length A Support Weight Catalog


(Inches) in/mm (lbs/kg) Number
SHC Ball Type Swivel Hanger Covers — Permit 20° swing from vertical
For 3-1/4” and 4” Octagonal Boxes
1/2 1.75/44.5 50/22.5 8438R
3/4 2.00/50.8 50/22.5 8436R
A

For 4” Square Boxes


1/2 1.75/44.5 50/22.5 8458R

A
3/4 2.00/50.8 50/22.5 8456R

1416 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Flexible Fixture Hangers
Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• EF hook and loop hangers
— Malleable iron for strength and safety.
— Hook and loop combination permits quick disconnect and
removal of fixture for maintenance.
— Offer inexpensive means of pendant flexible suspension of EFHM EFHF FHS
lighting fixtures.
— Permit free swing in any direction.
— EF jaw openings can be completely closed for added safety. Standard Finishes

Lighting
• FHS support hangers • Zinc electroplate and clear chromate
— Provide up to 350 lbs/158.8kg support for fluorescent fixtures
on the non-electrical side of mounting. Certifications and Compliances
— Straddle a maximum of 1-1/4” conduit and take 1/2” or 3/4” • CSA Certified: 065180
fixture hook or conduit.
Standard Materials
• Malleable iron

Lighting: Flexible Fixture Hangers — Ordinary Location


Size Length A Support Weight
(Inches) (in/mm) Lbs./Kg. Catalog Number
EF — Safety Support Hooks — With 3/8” jaw opening
EFHM—Male
1/2 2.63/66.8 200/90.0 EFHM-50
3/4 2.94/74.7 EFHM-75
A A EFHF—Female
1/2 2.00/50.8 200/90.0 EFHF-50
3/4 2.05/52.1 EFHF-75

EFHM EFHF

FHS — Support for Fixtures, Dummy Side — Straddles up to 1-1/4 trade size conduit — 11/32” diameter mounting holes, spaced
3-1/4” apart

A
1/2 or 3/4 3.31/87.1 350/157.5 FHS5075

Dimensions in Inches/Millimeters
A B C Catalog Number

0.25"/
1/2-14 NPT 2.00/50.8 2.63/66.8 EFHM-50
0.38"/
9.7 mm 6.4 mm R
3/4-14 NPT 2.13/54.1 2.88/73.2 EFHM-75

1/2-14 NPT 2.00/50.8 N/A EFHF-50


3/4-14 NPT 2.13/54.1 N/A EFHF-75

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1417


© September 2010
Flexible Fixture Hangers
Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Malleable iron for strength and safety.
• Hook and loop combination permits quick disconnect and
removal of fixture for maintenance.
• Offer inexpensive means of pendant flexible suspension of
lighting fixtures.
FHLM FHHM FHSN
• Permit free swing in any direction.
• EF and FHSN jaw openings can be completely closed for
added safety.
Lighting

Standard Materials
• Malleable iron
Standard Finishes
• Zinc electroplate and clear chromate
Certifications and Compliances
• CSA Certified: 065180
Lighting: Flexible Fixture Hangers — Ordinary Location

Illustrated Features

1418 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Flexible Fixture Hangers
Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Size Length A Support Weight


(Inches) (in/mm) Lbs/Kg Catalog Number
FH — Hanger Loops — With 5/8” diameter wireway
FHLM — Male
1/2 3.88/98.6 FHLM-50
350/157.5
3/4 4.13/104.9 FHLM-75
A A
FHLF — Female
1/2 3.25/82.6 FHLF-50
350/157.5
3/4 3.25/82.6 FHLF-75
FHLM FHLF

FH — Hanger Hooks — With 5/8” diameter wireway, 3/8” jaw opening

Lighting
FHHM — Male
1/2 3.88/98.6 FHHM-50
200/90.0
3/4 4.13/104.9 FHHM-75
A A
FHHF — Female
1/2 3.25/82.6 FHHF-50
200/90.0

Lighting: Flexible Fixture Hangers — Ordinary Location


3/4 3.25/82.6 FHHF-75
FHHM FHHF

FHHCG—Gasketed Fixture Hanger Hook — With 5/8” wire opening, 3/8” jaw opening, safety screw — As FHHM’s above, with
internal grommet to prevent moisture and dirt entry
FHHCG — Male

1/2 4.25/108.0 75/34.0 FHHCG-3750-SS


A
3/4 4.25//108.0 FHHCG-3775-SS

FHSN — Conduit Suspension Hanger — With safety strap—clamps around rigid conduit or IMC —Has 3/8” jaw opening
1/2 3.13/79.5 FHSN-50
3/4 3.25/82.6 150/67.5 FHSN-75
A 1 3.38/85.9 FHSN-100

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1419


© September 2010
Flexible Fixture Hangers
Receptacle and Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
• Permit quick disconnect and removal of fixture for
maintenance.
• Available in pendant or feed-thru.
• Available with matching cord set.
Standard Materials
• Malleable iron with steel cover
• Screws: stainless steel
Standard Finishes
• Malleable iron parts: triple-coat—(1) zinc electroplate, (2)
chromate, and (3) epoxy powder coat
Lighting

• Steel parts: zinc electroplate


GHPHP GHPHT
Lighting: Flexible Fixture Hangers — Ordinary Location

GHPHP and GHPHT — Receptacle Hangers

Catalog Number
Conduit Hub Size
(Inches) Voltage Hubbell Plug Pendant Feed-Thru
Furnished with assembled FS box, EFHM, safety lock, receptacle, and steel cover. Supports 200 lbs/ 90.7kg.
3/4 120 L5-15P GHPHP12 GHPHT12
3/4 208, 240 L6-15P GHPHP24 GHPHT24
3/4 277 L7-15P GHPHP27 GHPHT27
8.5” 6.06”
215.9mm 153.9mm 3/4 347 L37-20P GHPHP34 V GHPHT34 V
3/4 480 L8-20P GHPHP48 GHPHT48
3/4 600 L9-20P GHPHP60 V GHPHT60 V

GHPHP GHPHT

Cord Sets — With Loop —Supplied with 600 V, 90°C 3 conductor No. 16 SOW cable, locking plug and 3/4" FHLM loop
Voltage Amperes 2'/0.6 m Cord 3'/0.9 m Cord 4'/1.21 m Cord
120 15 G-HCPL-2-12 G-HCPL-3-12 G-HCPL-4-12
208, 240 15 G-HCPL-2-24 G-HCPL-3-24 G-HCPL-4-24
277 15 G-HCPL-2-27 G-HCPL-3-27 G-HCPL-4-27

347 20 G-HCPL-2-34 V G-HCPL-3-34 V G-HCPL-4-34 V


480 20 G-HCPL-2-48 G-HCPL-3-48 G-HCPL-4-48
600 20 G-HCPL-2-60 V G-HCPL-3-60 V G-HCPL-4-60 V

1420 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Power Hook for Industrial High Bay Luminaires V
Furnished with Receptacle, Plug, 18" 16-3 SO Cord and Loop Fixture Hanger

Applications
• Designed for suspension of HID, ­fluorescent and incandescent
lighting fixtures.
Features
• All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
• G-HBPH power hook for industrial luminaires
— Loop that suspends fixture cannot be removed until plug is
disconnected from power receptacle.
— 20 Amp plug, receptacle and cable are provided in all
voltages.
— Rotating plug after insertion locks plug in receptacle,

Lighting
eliminating plug ­fall-out.
— Loop and hook provide flexible mounting, ideal in areas
where vibration is encountered.
Standard Materials
• Copperfree (4/10 of 1% max.) cast aluminum
Standard Finishes
• Powder coat epoxy

Lighting: Flexible Fixture Hangers — Ordinary Location


Certifications and Compliances
• CSA Approved

Size (Inches) Voltage Catalog Number


3/4 120 G-HBPH-120
3/4 208 G-HBPH-208
3/4 240 G-HBPH-240
3/4 277 G-HBPH-277
3/4 347 G-HBPH-347
3/4 480 G-HBPH-480
3/4 600 G-HBPH-600

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1421


© September 2010
BKX Rigid Fixture Hangers V
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Class II, Division 1 and 2, Groups E, F, G


Class III,
Enclosure 4

Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
• All fixture hangers protect fixture against wind and vibration
damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Available in three depths.
• Accepts JB covers for ordinary ­location and AHG hangers for BKX Shallow Box BKX Deep Box
Class II hazardous locations.
Standard Materials
• Ferrous alloy and copperfree aluminum
Certifications and Compliances
• CSA Approved
Lighting
Lighting: Flexible Fixture Hangers — Explosionproof

1422 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
BKX Rigid Fixture Hangers V
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Class II, Division 1 and 2, Groups E, F, G


Class III,
Enclosure 4

Furnished with gasketed cover, four threaded conduit entries and 2 close-up plugs

Catalog Number
Fixture Stem Hub Size Enclosure Only Enclosure Only With Cover With Cover
Size (Inches) (Inches) Ferrous Alloy Aluminum Ferrous Alloy Aluminum
Shallow Box — 2-1/16
1/2 1/2 BKXS-1 BKXS-1A BKXS-11 BKXS-11A
1/2 3/4 BKXS-2 BKXS-2A BKXS-21 BKXS-21A
3/4 3/4 BKXS-2 BKXS-2A BKXS-22 BKXS-22A
Medium Box — 2-11/16
1/2 1/2 BKXM-1 BKXM-1A BKXM-11 BKXM-11A
1/2 3/4 BKXM-2 BKXM-2A BKXM-21 BKXM-21A
1/2 1 BKXM-3 BKXM-3A BKXM-31 BKXM-31A
3/4 3/4 BKXM-2 BKXM-2A BKXM-22 BKXM-22A
3/4 1 BKXM-3 BKXM-3A BKXM-32 BKXM-32A
Deep Box — 3-9/16
1/2 1/2 BKXD-1 BKXD-1A BKXD-11 BKXD-11A
1/2 3/4 BKXD-2 BKXD-2A BKXD-21 BKXD-21A
1/2 1 BKXD-3 BKXD-3A BKXD-31 BKXD-31A

Lighting
3/4 3/4 BKXD-2 BKXD-2A BKXD-22 BKXD-22A
3/4 1 BKXD-3 BKXD-3A BKXD-32 BKXD-32A
Covers with Gasket Attached
1/2 — — CBK-1G CBK-1GA

Lighting: Flexible Fixture Hangers — Explosionproof


3/4 — — CBK-2G CBK-2GA

Dimensions in Inches/Millimeters

Catalog Number A B
BKXS 1.31/33.3 1.50/38.1
BKXM 1.56/39.6 2.25/57.2
BKXD 1.56/39.6 3.00/76.2

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1423


© September 2010
CPU and EFHU Fixture Hangers
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Class I, Division 1 and 2,Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
• CPU and EFHU, EFHC, have smooth, rounded integral bushing
in each hub to protect conductor insulation.
Features
• Boxes have cast mounting lugs. Box and hub cover provide
a complete assembly for suspending lighting fixtures in
classified locations.
• CPU20 Hangers are used where fixture stem is less than 12”
long or with EXJF, ESD, or ESS where fixture stem is more than
12” long.
• EFHU Flexible Hangers meet NEC Sec. 501 requirement for CPU EFHU
flexible suspension where fixture stem is more than 12” long.
• Cushion design protects against vibration, and swivel action
(any direction up to 15° from vertical) protects fixture if
accidentally struck. Illustrated Features
• EFHU Flexible Cushion Hangers available in three spring ranges
to support fixture weights of 12 to 48 lbs / 5.4kg to 21.8kg and
48 to 120 lbs / 21.8kg to 54.4kg.
• CB205 Connection Block available for connecting all wires
without splices.
• Ground-joint mating surfaces assure flame-tight fit.
• Hanger has setscrew in stem hub to prevent fixture stem
Lighting

from turning.
Standard Materials
• CPU and EFHU: malleable iron or copperfree (4/10 of 1% max.
aluminum
• EFHU flexible hanger: brass fixture stem hub assembly
Standard Finishes
• CPU20 rigid fixture hangers body: triple-coat – 1) zinc
Lighting: Flexible Fixture Hangers — Explosionproof

electroplate, (2) chromate, and (3) epoxy powder coat


• CPU20 rigid fixture hangers cover: zinc electroplate and clear
chromate
• Separate CPU20 covers: zinc electroplate and clear chromate.
• EFHU flexible cushion fixture hangers: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat
Certifications and Compliances
• UL Listed: E10444
• UL Standard: 886
• Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)

1424 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
CPU and EFHU Fixture Hangers
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Class I, Division 1 and 2,Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

NEC Catalog Number CSA Catalog Number V


Conduit Size Fixture Stem Support Weight
(Inches) Size (Inches) (lbs/kg) Malleable Iron Malleable Iron Aluminum
CPU Fixture Hangers — Non-Flexible Type — Form 20
Furnished with cast mounting lugs, four threaded universal 3/4” hubs, four 3/4”
to 1/2” reducers, and three 1/2” close-up plugs.
1/2 or 3/4 1/2 250/112.5 CPU20-50 CPU20-50CN CPU20-50ACN
1/2 or 3/4 3/4 250/112.5 CPU20-75 CPU20-75CN CPU20-75ACN

EFHU Fixture Hangers — Flexible Cushion Type — Form 20


Furnished with cast mounting lugs, four threaded universal 3/4” hubs, four 3/4”
to 1/2” reducers, and three 1/2” close-up plugs.
1/2 or 3/4 3/4 12 to 48/
5.4 to 21.6 EFHU75-48 EFHU75-48CN —
1/2 or 3/4 3/4 48 to 120/
21.8 to 54.0 EFHU75-120 EFHU75-120CN —

Lighting
CPU Fixture Hanger Covers — Non-Flexible Type — Form 20
Furnished with screws.
1/2 250/112.5 CPSK20-50 CPSK20-50ACN CPSK20-50ACN
3/4 250/112.5 CPSK20-75 CPSK20-75ACN CPSK20-75ACN

Lighting: Flexible Fixture Hangers — Explosionproof


EFHU Fixture Hanger Covers — Flexible Cushion Type — Form 20
Furnished with screws. 3/4” to 1/2” reducer supplied for 1/2” fixture stem.
3/4 12 to 48/
5.4 to 21.6 EFH75-48 EFH75-48CN —
3/4 48 to 120/
21.8 to 54.0 EFH75-120 EFH75-120CN —

CPU and EFHU Connection Block Accessory


Mounts directly to drilled and tapped pads in CPU and EFHU hangers.
Phenolic, with fastening strap and mounting screws.
5-Wire. 20-Amp, 300 V Max. CB205 CB205CN CB205ACN

2.88"/
73.2 mm

CB205 CB205CN V

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1425


© September 2010
CPU and EFHU Fixture Hangers Dimensions
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

CPU50 and CPU75 Rigid Fixture Hanger

10-32 Thd.

.34"/ 5.56"/ 0.28"/


8.6 mm .25"/ 141.2 mm 7.1 mm Dia.
6.4 mm 2 Holes

.75"/19.1 mm 2.88"/ .25"/6.4 mm - 14 Thd.


2.00"/ 73.2 mm
50.8 mm
3.69"/
93.7 mm

6.38"/
3.81"/ 162.1mm
96.8 mm
4.63"/ 7.38"/187.5 mm
117.6 mm

EFHU Flexible Cushion Fixture Hanger

5.56"/ 0.28"/
Lighting

.75"/19.1 mm .25"/6.4 mm 141.2 mm 7.1 mm Dia.


2 Holes
.25"/6.4mm-20 Thd.
2.00"/
50.8 mm

2.19"/55.6 mm
Lighting: Flexible Fixture Hangers — Explosionproof

6.38"/
162.1mm
7.75"/
196.9 mm
7.38"/187.5 mm

.88"/
22.4 mm

1426 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivels
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.

Class I, Division 1 and 2, Groups A, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present. EXJF
Features
• EYJF Hanger Coupling
— Meets NEC Sec. 501 requirement for flexible suspension
where fixture stem is more than 12”/304.8 mm long.
— Watertight construction.
— Convenient method for attaching explosionproof lighting
fixtures to non-flexible hangers.
— Allows free swing of lighting fixture in any direction. Absorbs
shock, prevents damage to conduit and connections.
— Assures plumb hanging of fixture.
— Both end fittings are female with removable male close
nipples. To make union end-coupling, remove nipple from either
end and thread in a 1/2” or 3/4” UNY Union. ESD ESS
— Female end fittings have setscrews with screwdriver slot to
allow locking of conduit. Prevents turning of fixture stem and
nipple.
• ESS and ESD swivels for use with rigid fixture hangers where
fixture stem is more than 12”/304.8 mm long.
Illustrated Features
Standard Materials
• EXJF flexible hanger couplings: outer bronze braid, inner brass

Lighting
core with insulating liner and brass end fittings.
• ESD and ESS swivels: malleable iron.
Standard Finishes
• EXJF flexible couplings: natural finish.
• ESD and ESS swivels: triple-coat – 1) zinc electroplate, (2)
chromate, and (3) epoxy powder coat.
Options

Lighting: Flexible Fixture Hangers — Explosionproof


• EXJF available in stainless steel, add -SS to catalog number.
Certifications and Compliances
• UL Listed: E10444
• UL Standard: 886
• CSA Certified: 065182
• Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)
Related Products
• For unions, see Fittings Section.

 Shaded area on the following page indicates items suitable for Class I, Groups A and B in addition to Class I, Groups C and D; Class II, Groups E, F and G;
and Class III.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1427


© September 2010
Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivels
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.

Class I, Division 1 and 2, Groups A, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Size Inches/Millimeters Catalog


(Inches) Flexible Length Overall Length Number
EXJF Flexible Fixture Hanger ➊
Raintight construction. Supplied with two female hubs, each with a removable close nipple. Can
be used to make male to male, female to male or female to female. Setscrew with screwdriver slot
allows locking of conduit—prevents fixture stem from turning.
1/2 4.00/101.6 11.06/ 28.1 EXJF14
3/4 4.00/101.6 11.06/ 28.1 EXJF24
1/2 4.00/101.6 11.06/ 28.1 EXJF16
3/4 4.00/101.6 11.06/ 28.1 EXJF26
1/2 4.00/101.6 11.06/ 28.1 EXJF18
3/4 4.00/101.6 11.06/ 28.1 EXJF28
1/2 4.00/101.6 11.06/ 28.1 EXJF110
3/4 4.00/101.6 11.06/ 28.1 EXJF210
1/2 4.00/101.6 11.06/ 28.1 EXJF112
3/4 4.00/101.6 11.06/ 28.1 EXJF212
1/2 4.00/101.6 11.06/ 28.1 EXJF115
3/4 4.00/101.6 11.06/ 28.1 EXJF215
1/2 4.00/101.6 11.06/ 28.1 EXJF118
3/4 4.00/101.6 11.06/ 28.1 EXJF218
Lighting

Swivel Hangers — Setscrew with screwdriver slot allows locking of conduit — Prevents fixture stem from turning
ESD Swivel
15° swivel from center and full 360° free swing.
1/2 ESD50 ➋
Lighting: Flexible Fixture Hangers — Explosionproof

3/4 ESD75 ➋

ESS Swivel
15° swivel from center.
1/2 ESS50 ➋
3/4 ESS75 ➋

➊ Available in stainless steel. Add suffix -SS to catalog number. Consult your local sales representative.
➋ Not CSA Certified.
 Shaded area indicates items suitable for Class I, Groups A and B in addition to Class I, Groups C and D; Class II, Groups E, F and G; and Class III.

1428 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivel Dimensions
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.

ESS Swivel ESD Swivel

3.00"/
76.2 mm
3.00"/
76.2 mm

3.94"/ 1.88"/
100.1 mm 47.8 mm
3.31"/
84.1 mm
2.31"/
58.7 mm

3.00"/
76.2 mm

EXJF

Lighting
Size Dimensions in Inches/Millimeters
Inches A B C

Lighting: Flexible Fixture Hangers — Explosionproof


1/2 3.38/85.9 1.88/47.8 1.44/ 36.6
3/4 3.38/85.9 1.88/47.8 1.75/44.5

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1429


© September 2010
EFHC and EFHCA Fixture Hangers and Accessories
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups A*, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
• EFHC and EFHCA hangers have smooth, rounded integral
bushing in each hub to protect conductor insulation.
Features
• EFHC and EFHCA Fixture Hangers are used where fixture stem
is less than 12”/304.8 mm long or with EXJF, ESD, or ESS where
fixture stem is more than 12”/304.8 mm long.
• Raintight when used with O-Ring. EFHC EFHCA
• Provided with threaded removable cover for convenience in
pulling or splicing conductors.
• Mounting strap available for fastening EFHC or EFHCA to a
mounting surface.
• CB202 connection block available for convenience in
connecting line and fixture wires without splices.
• Hanger has setscrew in stem hub to prevent fixture stem
from turning. Illustrated Features
Standard Materials
• EFHC and EFHCA fixture hanger body: malleable iron
• EFHC and EFHCA fixture cover: copperfree (4/10 of 1% max.)
aluminum
• EFHC and EFHCA mounting strap and LC locking coupling:
Lighting

steel
Standard Finishes
• EFHC and EFHCA fixture hanger body: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat
• EFHC and EFHCA fixture hanger cover: epoxy powder coat
• EFHC/EFHCA mounting strap and LC locking coupling: zinc
electroplate
Lighting: Flexible Fixture Hangers — Explosionproof

Certifications and Compliances


• UL Listed: E10444
• UL Standard: 886
• CSA Certified: 025875
• Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)

 Shaded area on following page indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F and G; and Class III. Sealing fitting must be
installed adjacent to enclosure for all conduits for Group B location (EFHC Series).
* Suitable for Class I, Groups A, B, C, D.

1430 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
EFHC and EFHCA Fixture Hangers and Accessories
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups A*, B, C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Conduit Size (Inches) Fixture Stem Size (Inches) Catalog Number


EFHC Fixture Hanger
Class I, Groups B, C and D
Class II, Groups E, F and G
Class III
3/4 1/2 EFHC755 
3/4 3/4 EFHC7575 
1 1/2 EFHC1050 
1 3/4 EFHC1075 
EFHCA Fixture Hanger
Class I, Groups A*, B, C and D
Class II, Groups E, F and G
Class III
3/4 1/2 EFHCA7550 *
3/4 3/4 EFHCA7575 *
1 1/2 EFHCA1050 *
1 3/4 EFHCA1075 *
EFHC and EFHCA Connection Block Accessory – Porcelain
Designed to fit in hanger without fastening.
2 Wire, 20 Amp 277 Volt

Lighting
Maximum Wire Size CB202
Two No. 10 AWG large terminal
Two No. 14 AWG small terminal
EFHC and EFHCA Steel Mounting Strap
For fastening EFHC or EFHCA to a mounting surface.

Lighting: Flexible Fixture Hangers — Explosionproof


Add suffix S to above EFHCA or EFHC catalog numbers. Add suffix S

Dimensions
EFHCA and EFHC Fixture Hangers FHS Rigid Support

5.69"/ 4.31"/ .34"/


0.13"/ 4.56"/ 8.6 mm Dia.
3.3 mm 144.5 mm 0.94"/ 109.5 mm 115.8 mm
23.9 mm 2 Holes
3.25"/
1.13"/ 82.6 mm
28.7 mm
0.25"/
1.75"/ 6.4 mm
EFHC: 44.5 mm
2.25"/ 2.81"/
57.2 mm 71.4 mm 3.31"/
5.31"/ 84.1 mm
134.9 mm
EFHC:
3.13"/
79.5 mm
0.69"/
0.34"/ 17.5 mm
3.75"/ 8.6 mm Dia.
95.3 mm

* Suitable for Class I, Groups A, B, C and D.


 Shaded area indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F and G; and Class III.
Sealing fitting must be installed adjacent to enclosure for all conduits for Group B location (EFHC Series).

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1431


© September 2010
GRF Conduit Outlet Boxes and Fixture Hanger Covers and Canopies
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
• GRF conduit outlet boxes have smooth, rounded integral
bushing in each hub to protect conductor insulation.
Features
• GRF conduit outlet box with fixture hanger canopy or cover is GRFC GRF Canopy
used where fixture stem is less than 12”/304.8 mm long or with
EXJF, ESD, or ESS where fixture stem is more than 12” long.
• Raintight when used with O-Ring.
• For use with hub cover or canopy. canopy has threaded cover
opening for convenience in splicing conductors. Illustrated Features
• Cover and canopy hubs have set-screws with screwdriver slots
to allow locking of conduit. Prevents fixture stem form turning.
Standard Materials
• Malleable iron or copperfree (4/10 of 1% max.) aluminum
Standard Finishes
• Bodies: triple-coat – 1) zinc electroplate; (2) chromate, and (3)
epoxy powder coat
• Covers and canopies: zinc electroplate and clear chromate
Certifications and Compliances
• UL Standard: 886
Lighting

• Suitable for Class I, Division 1 and 2, if installed in compliance


with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)
Lighting: Flexible Fixture Hangers — Explosionproof

Dimensions in Inches/Millimeters
GRF Conduit Outlet Box GRF Canopy
2.31"/
58.7 mm

4.75"/ .81"/ 3.88"/


.38"/ 120.7 mm 20.6 mm 98.6 mm
.56"/
9.7 mm 14.2 mm 3.00"/
76.2 mm

5.38"/ 3.81"/ 1.50"/


136.7 mm 96.8 mm 2.13"/ 38.1 mm
54.1 mm
3.38"/ 3.38"/ 3.81"/
85.9 mm 96.8 mm
85.9 mm

.38"/ 1.19"/
9.7 mm 30.2 mm

1432 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
GRF Conduit Outlet Boxes and Fixture Hanger Covers and Canopies
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Class I, Division 1 and 2, Groups C, D


Class II, Division 1 and 2, Groups E, F, G
Class III

NEC Catalog Number CSA Catalog Number V


Conduit Size Fixture Stem Size
(Inches) (Inches) Malleable Iron Aluminum Malleable Iron
GRF Flanged Conduit Outlet Boxes — Form 1, Less Cover — For use with GRF fixture hanger canopies and covers below — Nominal
diameter of cover opening is 3-3/8” — Furnished with threaded hubs and ground screw — Flange has four 3/8” mounting slots

1/2 GRFC-50LC — GRFC-50LCCN

3/4 GRFC-75LC — GRFC-75LCCN

1 GRFC-100LC — GRFC-100LCCN

1/2 GRFL-50LC — GRFL-50LCCN

3/4 GRFL-75LC — GRFL-75LCCN

1 GRFL-100LC — GRFL-100LCCN

1/2 GRFT-50LC — GRFT-50LCCN

3/4 GRFT-75LC — GRFT-75LCCN

1 GRFT-100LC — GRFT-100LCCN

1/2 GRFX-50LC — GRFX-50LCCN

Lighting
3/4 GRFX-75LC GRFX-50ALCCN GRFX-75LCCN

1 GRFX-100LC GRFX-75ALCCN GRFX-100LCN

GRF Fixture Covers – Form 1 — Furnished with external threads for attachment to GRF mounting box above
Threaded Hub Cover
1/2 GRK-50 — GRK-50CN

Lighting: Flexible Fixture Hangers — Explosionproof


3/4 GRK-75 — GRK-75CN

Union Hub Cover


3/4 GRK-75U — GRK-75UCN

GRF Fixture Canopies – Form 1 — Furnished with external threads for attachment to GRF mounting box above — Threaded cover
opening on side for convenience in splicing
1/2 GRK-50C — GRK-50CCN
3/4 GRK-75C — GRK-75CCN
1 GRK-100C — GRK-100CCN

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1433


© September 2010
Fixture Hanger Bracket and Accessories
UNILETS® for use with Threaded Metal Conduit.

NPT Size (Inches) Support Weight (lbs/kg) Catalog Number


Fixture Hanger Brackets
Suitable for use with fixtures with 3/4-14 NPT conduit openings or hubs. Mounts directly to ceiling or
wall separately from conduit system. Catalog number includes two brackets and two hexhead bolts.
Iron with gray epoxy finish.

3/4 200/90.0 FHS1

Ceiling Mount Wall Mount


Projects light downward (90°). Projects light at 45° angle. Shown
Shown mounted to Appleton mounted to Appleton AH260-118
AH260-118 explosionproof explosionproof fluorescent lighting
fluorescent lighting fixture. fixture.

Safety Support Hooks and Rigid Support for Dummy Side of Lighting Fixtures
Complete assembly includes two hooks and one rigid support. Each hook supplied with a screw for
closing 3/8” jaw opening. Rigid Support straddles max. 1-1/4” conduit. (Chain shown in installation
view not furnished.)
3/4 200/90.0 AC-KT
Lighting
Lighting: Flexible Fixture Hangers — Explosionproof

LC Steel Locking Couplings


Setscrews with Allen head fasten on outside of hub and fixture stem. Prevents fixture stem from turning
in hubs not normally supplied with setscrews. 3/4” fixture stem.
3/4 — SLC75

1 — SLC1075
Safety Support Hooks for Dummy Side of Lighting Fixtures
Supplied with screw for closing 3/8” jaw opening.
Male
1/2 200/90.0 EFHM-50
3/4 EFHM-75
Female
1/2 200/90.0 EFHF-50
3/4 EFHF-75
Rigid Support for Fluorescent Lighting Fixtures (Dummy Side)
Will straddle max. 1-1/4” conduit.
1/2 and 3/4 350/157.5 FHS5075

1434 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Fixture Hanger Bracket and Accessories
UNILETS® for use with Threaded Metal Conduit.

Dimensions of FHS1 Fixture Hanger Bracket

2.50"/ 0.19"/4.8 mm R18


3/4 - 14 Tapered 63.5 mm
Pipe Thread 1.25"/
31.8 mm
2.50"/63.5 mm

1.25"/31.8 mm 1.13"/28.7 mm Dia. Hole

1.69"/42.9 mm
6.38"/162.1 mm
1.00"/ 0.5"/12.7 mm R
25.4 mm

1.50"/ .67"/ .67"/


17.0 mm 17.0 mm
3.81 mm

1.25"/31.8 mm

2.50"/ .31"/7.9 mm
63.5 mm

Lighting
Lighting: Flexible Fixture Hangers — Explosionproof

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1435


© September 2010
HID Temporary Lighting
Designed and Packaged for Quick Installation

Applications
• More and more contractors are using temporary HID fixtures to
light their work sites. Instead of modifying Low-Bay fixtures for
this application, McGill’s HID Temporary Lighting allows them to
buy something faster and easier.
Features
• 400 W Pulse Start Metal Halide lamp provides over 6 foot/1.8
meters candles of illumination at a 20 ft./6.1 meter mounting
height.
• McGill offers lighting layouts to conform with OSHA
requirements for light output.
• Type “O” lamp and mogul socket complies with NEC 2008
Article 410.13(F)(5) and ANSI C78.387.
• Quick-attach durable 10”/254 mm welded wire guard mounts
directly to the body to protect lamp and lampholder from
accidental impact.
• Fixture is factory wired at 120 Volt, but can be rewired internally
for other voltage settings.
• 3'/0.9 m cord with 5-15P molded plug on end.
• Compact size for easy handling.
• Low-profile fixture design keeps it up and out of the way of
activity below.
Lighting: McGill Temporary

• High light output and long lamp life. Shown with optional bottom trap
• Open-air ballast for cooler operation.
• Hook with locking feature.
• (2) 3/4”/19.1 mm knock-outs for conduit access.
• Single durable package design makes it easier for distributors to Illustrated Feature
stock and more organized for contractors on the job site.
• Quick and easy to assemble.
• Optional bottom trap available.
Spring-lock hook allows
Standard Materials contractors to mount the
• Enclosure: Heavy-duty steel with powder coated finish unit in seconds, without
• Lamp: 400 Watt Pulse Start Metal Halide: O-Type, BT37 Clear, the need for tools.
EX39 (Exclusionary Mogul Base)
• Multi-Tap ballast: 120, 208, 240, 277 Volt: Factory wired at 120
Volt
• Power cord: 3 FT/0.9 M, 18/3 SJTW, 120 Volt, 15 Amp cord
complete with NEMA 5-15 molded plug
Lighting

• Lamp guard: 11 ga. white painted steel Dimensions in Inches/Millimeters


• Mounting hook: 11 ga. steel 4.26"/108.2 mm
3.52"/
Certifications and Compliances 89.4 mm 0.12"/
3.0 mm
2.21"/
0.7 mm
• UL and cUL Listed: E196293
3 ft/0.9 m

• UL Standard: UL 1598
• Suitable for damp locations
8.0"/2.4 mm

Options
• Optional bottom trap available

Catalog Number

400 W Fixture with Guard TL40PMTO


11.76"/3.6 mm

Bottom Guard Trap TLTRAPW

Replacement Lamp Guard TLGUARDW

Replacement Lamp:
GMP400BUPS
400 W PSMH, O-Type, BT37 Clear, EX39
9.25"/2.8 mm

1436 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
String-O-Lights
Low Cost Temporary Lighting

Applications

OPEN CONDUCTOR
• McGill offers a variety of temporary job site lighting systems,
from reusable, low cost cable versions to an assortment of open
conductor styles.
Features
• They are available in 50’ to 200’/15.2 to 61 meters lengths of 2-
and 3-conductor and 12 and 14 gauge wire with 5 to 10 cage/
socket assemblies.
• Brass sockets are enclosed in weather-resistant molded PVC,
and plastic connectors provide greater reliability.
• Packaging provides tangle-free, on-the-job handling and
installation.
• Easy-open cages snap open and closed for faster installation Flat Wire Cable Style
without tools and easy lamp replacements.
• Non-corrosive cages are fastened to sockets by a non-corrosive
collar and accommodate up to 200 Watt bulbs. Illustrated Features

FLATWIRE
• Cable styles meet 2008 NEC requirements.
• Convenient, economical temporary lighting.
• 110’/30.5 m messenger wire available to support string where
needed.
• Fully assembled; ready for installation.
• Weather-resistant sockets.

Lighting: McGill Temporary


• All parts sold separately.
Standard Materials Easy-Open Cages
• Cages: yellow plastic
Certification and Compliance

MOLDED CABLE
• Molded Cable Version
— UL Listed: E88103
— UL Standard: 1088
— Meets OSHA requirements
— CSA Certified: LL89639 V
— CSA Standard: C22.2 No. 12

Packaging

Lighting
No. of Socket Catalog Numbers
Length Cages/ Spacing
Ft/M Sockets Ft/M for A-23 Bulb for PS-30 Bulb
Molded Cable Styles — UL Listed
12/2-SJTW cable with plug/boot on one end and connector/cap on other end 100/30.5 10 10/3.0 2252-0018 —
12/2-SJTW cable 100/30.5 10 10/3.0 2252-0019 —
12/2-STW extra hard usage cable with weather protected plug/boot 100/30.5 10 10/3.0 2252-5007 V —
12/3-SJTW cable with 5-15 plug/boot on one end and connector/cap on other end 100/30.5 10 10/3.0 2252-0026 —
12/3-SJTW cable 100/30.5 10 10/3.0 2252-0027 —
14/2-SJTW cable 100/30.5 10 10/3.0 2252-0007 2252-0009
14/2-SJTW cable with plug/protective rubber boot on one end 100/30.5 10 10/3.0 2252-0012 2252-0013
14/2-SJTW cable 50/15.2 5 10/3.0 2252-0031 * —
14/3-SJTW cable 100/30.5 10 10/3.0 2252-0014 2252-0015
14/3-SJTW cable with 5-15 plug/boot on one end and connector/cap on other end 100/30.5 10 10/3.0 2252-0024 2252-0025
14/3-SJTW cable 50/15.2 5 10/3.0 2252-0034 * —
* Contact Technical Service for UL data
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1437


© September 2010
String-O-Lights
Low Cost Temporary Lighting

No. of Socket Catalog Number


Length Cages/ Spacing
Ft/M Sockets Ft/M for A-23 Bulb for PS-30 Bulb
Flat Wire Styles
14/2 Flat wire cable 100/30.5 10 10/3.0 2252-0035 —
14/2 Flat wire cable 50/15.2 5 10/3.0 2252-0038 —
14/2 Flat wire cable 200/61.0 10 20/6.1 2252-0043 —
Flat Wire Styles with Plug
14/2 Flat wire cable with 1-15P plug on one end 100/30.5 10 10/3.0 2252-0040 —
14/2 Flat wire cable with 1-15P plug on one end 50/15.2 5 10/3.0 2252-0041 —
14/2 Flat wire cable with 1-15P plug on one end 200/61.0 10 20/6.1 2252-0044 —
Open Conductor Styles
2-conductor, 14 gauge wire 100/30.5 10 10/3.0 2252-4040 2252-4060
2-conductor, 14 gauge wire, right-hand screw shells 100/30.5 10 10/3.0 2252-1010 2252-2020
2-conductor, 14 gauge wire, left-hand screw shells 100/30.5 10 10/3.0 2253-1010 2253-2020
2-conductor, 14 gauge wire 50/15.2 5 10/3.0 2252-0006 —
Lighting: McGill Temporary

2-conductor, 14 gauge wire 200/61.0 10 20/6.1 2252-0008 2252-2008

Accessories and Replacement Parts


Catalog Number
Hangers (for open conductor styles) 2252-1025

Cages
Catalog Number
for A-23 Bulb for PS-30 Bulb
For use with McGill String-O-Lights
Lighting

Single plastic replacement cage only MCG2250 —


Single plastic replacement cage with screw collar 2250-S 2255
Single plastic replacement cage with right-hand socket assembly and hanger 2252 2256
Single plastic replacement cage with left-hand socket assembly and hanger 2253 —
Single plastic replacement cage with hanger (no socket) 2254 —
For use with most types of Lampholders
Single plastic cage only 2259 —

Socket/Wire Sets
Catalog Number
Weather-resistant 600 Watt/250 Volt, 4-1/2”/114.3 mm leads of 14 gauge wire, vulcanized, pigtail socket;
4017
right-hand thread
Weather-resistant 600 Watt/250 Volt, 4-1/2”/114.3 mm leads of 14 gauge wire, vulcanized, pigtail socket;
4018
left-hand thread
Messenger wire: 110’/30.5 meters 3/32”/2.3 mm dia. 7 x 7 stranded galvanized aircraft cable 2251

1438 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
7000 Series Industrial Extension Lights
Rubber Handle without Receptacle

Features
• 7000 Series extension lights resist damage and deterioration.
• Open-end or NO-ROL closed-end cages of extra-heavy,
electrically welded, wire accommodate up to 200 Watt bulbs.
• Ideal for use where safety codes prohibit outlets in handles.
• Easy relamping cage.
• Internal strain relief withstands 30­ lb/9.1 kg. pull test.
• All-weather cords with molded plugs.
• Long-life Levolier™ switch mechanism in handle with protective
thumb guard.
Standard Materials 7000-SG 7001-SRG ➋
• Cage: 10 gauge steel wire
• Cord: thermoplastic
• Handle: yellow, grease-resistant, high quality rubber
Options
• 15 Amp, 120 Volt CSA Certified versions available. Items
available in a CSA version will be marked with a V. Add the
prefix C to the beginning of the catalog number.
Certifications and Compliances ➊
• UL Listed (with cord): E59071
• UL Listed (without cord): E59054

Lighting: McGill Temporary


• UL Standard: 153
• Meets OSHA requirements
• CSA Certified (with cord): LL89639 V
• CSA Certified (without cord): LL56247 V
• CSA Standard: C22.2 No. 12
7025-SRG 7000-RIG

Lighting
7999-RGH

➊ 100 Watt Maximum for UL Listing and CSA Certification.


➋ Not UL Listed or CSA Certified.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1439


© September 2010
7000 Series Industrial Extension Lights
Rubber Handle without Receptacle

Catalog Numbers
with 1'/ 0.3m with 25’/7.6m with 50’/15.2m
with out Cord
16/3-SJTW Cord 16/3-SJTW Cord 16/3-SJTW Cord
Closed-End Extension Lights
Handle and cage 7000-G — 7025-G 7050-G
Handle and cage with reflector 7000-RG — 7025-RG 7050-RG
Handle and cage with switch 7000-SG — 7025-SG 7050-SG
Handle and cage with switch and reflector 7000-SRG 7012-SRG ➊ 7025-SRG 7050-SRG
Handle and cage with switch and reflector and GFCI — — 7025-SRG-GFCI —
Insulated cage, reflector (100 Watt max.) 7000-RIG — 7025-RIG 7050-RIG
Non-metallic cage, reflector (100 Watt max.) 7999-RGH — 7925-RGH 7950-RGH
Replacement Cord Sets
Cord set with molded plugs 6229-1 ➋ 6229-2 ➋
Catalog Number ➋
for 60-100 Watt for 200 Watt
Lighting: McGill Temporary

Open-End Extension Lights (without cord)


Handle and cage 7001-G 7002-G
Handle and cage with reflector 7001-RG 7002-RG
Handle and cage with switch 7001-SG 7002-SG
Handle and cage with switch and reflector 7001-SRG 7002-SRG
Accessories and Replacement Parts
Catalog Number
With Out Reflector With Reflector
Cages
Closed-end cage for 7000 8171 8170
Open-end cage (100 Watt lamp max.) 8133 8162
Lighting

Open-end cage (200 Watt lamp max.) 8335-2 8336


Closed-end vinyl insulated cage (100 Watt A-21) 08171 08170
Open-end vinyl insulated cage (100 Watt lamp max.) — 08162
Open-end vinyl insulated cage (200 Watt lamp max.) — 08336
Non-metallic cage for 7999 — 8224

Catalog Number
Catalog Number With Out Switch With Switch
Handles and Sockets
Handle for 7000, 7001, 7002 — 6403 6404-1
Handle and socket for 7000, 7001, 7002 — 8959 8950
Socket for 7000, 7001, 7002 — 4015 4005
Grounding clamp 9232 — —

➊ UL Listed for cord reel usage only.


➋ Not UL Listed.

1440 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
7000 Series Industrial Extension Lights V
CSA Certification Only. Rubber Handle without Receptacle

Catalog Numbers
with 1'/0.3 m with 25’/7.6 m with 50’/15.2 m
with out Cord 16/3-SJTW Cord 16/3-SJTW Cord 16/3-SJTW Cord
Closed-End Extension Lights
Handle and cage C7000-G — C7025-G C7050-G
Handle and cage with reflector C7000-RG — C7025-RG C7050-RG
Handle and cage with switch C7000-SG — C7025-SG C7050-SG
Handle and cage with switch and reflector C7000-SRG C7012-SRG ➊ C7025-SRG C7050-SRG
Insulated cage, reflector (100 Watt max.) C7000-RIG — C7025-RIG C7050-RIG
Non-metallic cage, reflector (100 Watt max.) C7999-RGH — C7925-RGH C7950-RGH
Replacement Cord Sets
Cord set with molded plugs C6229-1 ➋ C6229-2 ➋
Catalog Number ➋
for 60-100 Watt for 200 Watt
Open-End Extension Lights (without cord)

Lighting: McGill Temporary


Handle and cage C7001-G C7002-G
Handle and cage with reflector C7001-RG C7002-RG
Handle and cage with switch C7001-SG C7002-SG
Handle and cage with switch and reflector C7001-SRG C7002-SRG
Accessories and Replacement Parts
Catalog Number
With Out Reflector With Reflector
Cages
Closed-end cage for 7000 8171 8170
Open-end cage (100 Watt lamp max.) 8133 8162
Open-end cage (200 Watt lamp max.) 8335-2 8336

Lighting
Closed-end vinyl insulated cage (100 Watt A-21) 08171 08170
Open-end vinyl insulated cage (100 Watt lamp max.) — 08162
Open-end vinyl insulated cage (200 Watt lamp max.) — 08336
Non-metallic cage for 7999 — 8224

Catalog Number
With Out Switch With Switch
Handles and Sockets
Handle for 7000, 7001, 7002 — 6403 6404-1
Handle and socket for 7000, 7001, 7002 — 8959 8950
Socket for 7000, 7001, 7002 — 4015 4005
Grounding clamp 9232 — —

➊ CSA Listed for cord reel usage only.


➋ Not CSA Listed.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1441


© September 2010
7000-38 Series Industrial Extension Lights
For PAR-38 Lamps

Applications
• These extension lights are ideal for temporary flood lighting,
railroad car inspections, spot light inspecting of the internal
conditions of large well pipes, and other applications requiring
intense lighting.
Features
• 7000 Series extension lights resist damage and deterioration.
• Open-end of extra-heavy, electrically welded, wire
accommodates up to 200 Watt bulbs.
• Ideal for use where safety codes prohibit outlets in handles.
• Easy relamping cage.
• Internal strain relief withstands 30­ lb/9.1 kg. pull test.
• All-weather cords with molded plugs. 7000-SG-38
• Long-life Levolier™ switch mechanism in handle with protective
thumb guard.
Standard Materials Certifications and Compliances
• Cage: 10 gauge steel wire • CSA Certified (with cord): LL89639
• Cord: thermoplastic • CSA Certified (without cord): LL56247
• Handle: yellow, grease-resistant, high quality rubber • CSA Standard: C22.2 No. 12
Lighting: McGill Temporary

Catalog Number
with 25'/7.6m with 50'/15.2m
with out Cord 16/3-SJTW Cord 16/3-SJTW Cord
Handle and cage 7000-G-38 7025-G-38 7050-G-38
Handle and cage C7000-G-38 V C7025-G-38 V C7050-G-38 V
Handle and cage with switch 7000-SG-38 7025-SG-38 7050-SG-38
Handle and cage with switch C7000-SG-38 V C7025-SG-38 V C7050-SG-38 V

Accessories and Replacement Parts


Lighting

Catalog Number
With Out Reflector With Reflector with Trap
Cages
Cage for 7000-38 1455-38 — 1455-38-T

Catalog Number
With Out Switch With Switch
Handles and Sockets
Handle for 7000, 7001, 7002 6403 6404-1
Grounding clamp 8959 8950
25’/7.6m 50’/15.2m
16/3-SJTW 16/3-SJTW
Cord Sets
Cord set with molded plugs 6229-1 6229-2

V CSA Certification only.

1442 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
6000 Series Commercial-Duty Extension Lights
Polypropylene Handle with Receptacle

Features
• Commercial-duty extension lights resist impact, abrasion and oil.
• Three wire grounded handles with convenience receptacle.
• Easy-open, NO-ROL cage with rotating hook saves time and
permits precise lamp positioning.
• Plated metal parts resist rust and corrosion.
• All-weather cords have molded plugs.
• 10 Amp, 125 Vac receptacle rating.
• Cage accommodates 100 Watt max. bulbs.
• Push-through switch.
• Accommodates 16/3 cord type only.
Standard Materials
• Cord: 16/3-SJTW yellow thermoplastic 6025-SRG
• Cage: 10 gauge steel
Standard Finish
• Cage: zinc-plated
Certifications and Compliances ➊
• UL Listed: E59071
• UL Standard: 153
• Meets OSHA requirements
• CSA Certified: LL89639

Lighting: McGill Temporary


• Meets OSHA requirements

Catalog Numbers
with 1'/0.3m with 25’/7.6 m with 50’/15.2 m
16/3-SJTW Cord 16/3-SJTW Cord 16/3-SJTW Cord
Handle and cage with switch and reflector 6012-SRG ➋ 6025-SRG 6050-SRG
Handle and cage with switch and reflector C6012-SRG ➌ V C6025-SRG V C6050-SRG V
Handle and cage with switch and reflector and GFCI — 6025-SRG-GFCI —

Lighting

➊ 100 Watt Maximum for UL Listing and CSA Certification.


➋ UL Listed for cord reel usage only.
➌ CSA Listed for cord reel usage only.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1443


© September 2010
5000 Series Industrial Extension Lights
Thermoplastic Handle With or Without Receptacle

Features
• Industrial-duty extension lights resist impact, abrasion and oil.
• Yellow handles with receptacle, yellow cords, and grounded
cages enhance safety, while easy-open cages speed relamping.
• All-weather cords have molded plugs for durability.
• Cages feature rotating hooks and NO-ROL design for accurate
light positioning.
• Accommodates up to 200 Watt rough service bulbs.
• Meets NEC requirements for power tool grounding.
• 13 Amp, 125 Vac receptacle rating. 5000-SRG 5000-SRG, easy open cage
• Long-life Levolier™ switch mechanism in handle with protective
thumb guard.
Standard Materials
• Cords: 16/3-SJTW thermoplastic
• Cages: 10 gauge steel
Standard Finish
• Cages: zinc plated, chrome finish
Options
• 15 Amp, 120 Volt CSA Certified versions available. Items 5025-SRG
available in a CSA version will be marked with a V. Add the
prefix C to the beginning of the catalog number.
Lighting: McGill Temporary

Certifications and Compliances ➊


• UL Listed (with cord): E59071
• UL Listed (without cord): E59054
• UL Standard: 153
• Meets OSHA requirements
• CSA Certified (with cord): LL89639 V
• CSA Certified (without cord): LL56247 V
• CSA Standard: C22.2 No. 12
Lighting

➊ 100 Watt Maximum for UL Listing and CSA Certification.


V CSA Certification only.

1444 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
5000 Series Industrial Extension Lights
Thermoplastic Handle With or Without Receptacle

Catalog Numbers
with 1'/ 0.3m with 25’/7.6m with 50’/15.2m
with out Cord 16/3-SJTW Cord 16/3-SJTW Cord 16/3-SJTW Cord
Closed-End Extension Lights
Handle and cage 5000-G — 5025-G 5050-G
Handle and cage C5000-G V — C5025-G V C5050-G V
Handle and cage with reflector 5000-RG — 5025-RG 5050-RG
Handle and cage with reflector C5000-RG V — C5025-RG V C5050-RG V
Handle and cage with switch 5000-SG — 5025-SG 5050-SG
Handle and cage with switch C5000-SG V — C5025-SG V C5050-SG V
Handle and cage with switch and reflector 5000-SRG 5012-SRG ➊ 5025-SRG 5050-SRG
Handle and cage with switch and reflector C5000-SRG V 5012-SRG ➊ C5025-SRG V C5050-SRG V
Handle and cage with switch and reflector and GFCI — — 5025-SRG-GFCI —
Handle and cage, no receptacle 5000-GN — 5025-GN 5050-GN
Handle and cage, no receptacle C5000-GN V — C5025-GN V C5050-GN V
Handle and cage with reflector, no receptacle 5000-RGN — 5025-RGN 5050-RGN
Handle and cage with reflector, no receptacle C5000-RGN V — C5025-RGN V C5050-RGN V
Handle and cage with switch, no receptacle 5000-SGN — 5025-SGN 5050-SGN

Lighting: McGill Temporary


Handle and cage with switch, no receptacle C5000-SGN V — C5025-SGN V C5050-SGN V
Handle and cage with switch and reflector, no receptacle 5000-SRGN — 5025-SRGN 5050-SRGN
Handle and cage with switch and reflector, no receptacle C5000-SRGN V — C5025-SRGN V C5050-SRGN V
Handle and non-metallic cage — — 5999-GH —
Handle and non-metallic cage — — C5999-GH V —
Handle and non-metallic cage with reflector — — 5999-RGH —
Handle and non-metallic cage with reflector — — C5999-RGH V —
Handle and non-metallic cage with switch — — 5999-SGH —
Handle and non-metallic cage with switch — — C5999-SGH V —
Handle and non-metallic cage with switch and reflector — — 5999-SRGH —
Handle and non-metallic cage with switch and reflector — — C5999-SRGH V —
Replacement Cord Sets

Lighting
Cord set with molded plugs 6229-1 6229-2
Catalog Number
With Out Reflector With Reflector
Cages
Wire cage 8171 8170
Vinyl insulated metal cage (100 Watt A-21) 08171 08170
Non-metallic cage (100 Watt A-19) — 8224
Catalog Number
With Out Switch With Switch
Handles and Sockets
Handle and socket for 5000 0877 0865
Handle and socket for 5000-N 0877-N 0865-N
Socket for 5000 and 5000-N 00868 868

➊ 100 Watt Maximum for UL Listing and CSA Certification.


V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1445


© September 2010
Industrial Extension Lights

Features
• RE-HL5SRG and RE-HL7G
– All-weather cords with molded plugs
– Long-life Levolier™ switch mechanism in handle with
protective thumb guard
• RE-HLG-P and RE-VHL100N
– Easy to handle and service RE-HL55RG
– Capable of long, continuous operation in some of industry’s
most demanding environments
Standard Materials
• RE-HL5SRG and RE-HL7G
– Cage: 10 gauge steel wire
– Handle: yellow, grease-resistant, high quality rubber
• RE-HLG-P and RE-VHL100N
– Handle and cage: nonmetallic composition
Certifications and Compliances RE-HLG-P
• UL Listed: E65418
• UL Standard:153
Lighting: McGill Temporary

Max. Lamp Weight Ea. Catalog


Description
Watts Oz./Grams Number
Grounded handlamp with switch and receptacle

With yellow malamine phenolic handle and deluxe


wire metal guard. Use with maximum 16/3 SO or 100 W 15/425 RE-HL5SRG
SJOOW cord.

Grounded handlamp without switch or receptacle

With yellow rubber handle and vinyl coated wire metal


guard. Meets OSHA requirements and NEC 511.4(B) 100 W 20/567 RE-HL7G
Lighting

(2) for commercial garages, repair and storage

Grounded handlamp without switch or receptacle

With yellow polypropylene handle and guard.


Meets OSHA requirements and NEC 511.4(B)(2) for
75 W 8/227 RE-HLG-P *
commercial garages, repair and storage

Grounded NEMA 4X handlamp without switch or receptacle

Enclosed and gasketed handlamp with yellow


polyester handle and teflon globe. For indoor use
100 W 19/539 RE-VHL100N *
only. Meets OSHA requirements and NEC 511.4(B)(2)
for commercial garages, repair, and storage.

* NOT UL Listed.

1446 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Handy Compact Fluorescent Work Light
13 Watt

Applications
• The compact light provides cool operation, allowing for work
in small areas without excessive heat build-up or burns from
accidental contact.
Features
• This energy-efficient work light features an exclusive 10,000
hour, 13 Watt rough service twin tube fluorescent lamp.
• Optional magnetic base with removable plastic swivel hook
available.
• 13 Watt, 120 Volt PLC, 0.59"/15 mm lamp.
• Double insulated, enclosed electrical components.
• Convenient on/off switch under domed cap.
• Durable construction for industrial and commercial applications.
5331-0001
Standard Materials
• Cord and molded plug: 18 gauge SJTOW oil-resistant
• Outer tube with reflector break-resistant polycarbonate
Certifications and Compliances
• UL Listed: E59071
• UL Standard: 153

Lighting: McGill Temporary


5331-0008
(Magnetic base and removable swivel hook assembly)

Catalog Number
120V, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 25’/7.6 m, 18/2-SJTOW yellow cord,
5331-0001
in-line ballast, and built-in switch
Replacement 13 Watt lamp for 5331-0001 (shock resistant, rough service) 5331-0002
Magnetic base and removable swivel hook assembly 5331-0008
Scratch Guard 5331-0035

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1447


© September 2010
Rough Service Fluorescent Lamp
13 Watt

Applications
• The compact light provides cool operation, protecting personnel
from accidental contact burns.
Features
• This 13 Watt energy-efficient work lamp provides light output
equivalent to a 75-100 Watt incandescent with lamp life rated at
10,000 hours.
• Optional tool tap and scratch guard are available.
• Reflector directs light to work surface away from eyes.
• Scratch guard protects light.
• On/off switch, located under handle is water and dust resistant.
• Compact ballast located in handle.
• Rubber bumpers and handle protect light on impact. 5331-0034
• Exclusive in-line tool tap (110 Volt) with outlet cover.
Standard Materials
• Cord and molded plug: 16 or 18 gauge SJTOW oil-resistant
• Adjustable hooks with cushion tips: spring steel
Certifications and Compliances
• UL Listed: E59071 5331-0008
• UL Standard: 153 (Magnetic base and removable swivel hook assembly)
Lighting: McGill Temporary

Catalog Number
Fluorescent Lamp
13 Watt Handi-Light with tool tap and scratch guard, 25’/7.6 m 16/3-SJTOW 5331-0031
13 Watt Handi-Light with scratch guard and 25’/7.6 m 18/2-SJTOW 5331-0032
13 Watt Handi-Light with Saf-T-Tie insert: cord locking mechanism, tool tap, scratch guard and
5331-0034
18”/457.2 mm 16/3-SJTOW
Accessories and Replacement Parts
13 Watt Handi-Light head kit with switch, ballast and scratch guard 5331-0033
Lighting

Scratch guard only 5331-0035


13 Watt Handi-Light head kit with switch and scratch guard; less ballast 5331-0036
13 Watt lamp only (shock resistant, rough service) 5331-0002
Magnetic base and removable swivel hook assembly 5331-0008

1448 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Fluorescent Work Lights
12 Volt, 13 Watt

Applications
• For applications requiring low-voltage, bright, energy-efficient
lighting.
Features
• The light is powered by a printed circuit, solid state ballast
connected to the lamp base.
• Hook with protective plastic tip, allowing for the light to hang on
user’s belt or shoulder strap for hands-free operation.
• Models available with 20’/6.1 m 18/2-SJTOW oil-resistant, low 5331-0003
temperature cord or 1’/0.3 m to 5’/1.5 m neoprene black coil
cord; both with male lighter plugs on the ends.
• Ideal for use in confined areas.
• Replaceable 13 Watt, 12 Volt, 12.5 Amp Vac twin tube lamp.
• Ballast designed to operate at -4 °F/-20 ˚C.
• Ballast protected against voltage surges up to 18 Volts.
• Convenient on/off switch.
• Optional battery pack with charger available.
• Optional magnetic base with removable plastic swivel hook
available. 5331-0004
Standard Materials
• Single metal hook with protective plastic tip

Lighting: McGill Temporary


• Break-resistant polycarbonate outer tube with reflector

5331-0008
(Magnetic base and removable swivel hook assembly)

Catalog Number

Lighting
Work Lights
12 Volt, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 20’/6.1 m 18/2-SJTOW yellow cord
5331-0003
and male lighter plug
12 Volt, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 1’/0.3m-5’/1.5 m coil cord and male
5331-0004
lighter plug
Accessories and Replacement Parts
13 Watt lamp only (shock resistant, rough service) 5331-0002
Magnetic base and removable swivel hook assembly 5331-0008

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1449


© September 2010
Battery Pack with Charger

Applications
• Ideal for use with 12 Volt, 13 Watt fluorescent work lights when
working in remote areas. Charger plugs into 120 Vac and
charges at 1.2 amps, 12 Vdc. Charger is furnished with 6’/1.8
m cord and male lighter plug to insert into the female outlet of
the battery. Charger then plugs directly into a 120 Volt outlet.
If battery is discharged to recommended maximum depth,
the charger requires 16 hours to fully recharge. As battery is
charged, the output of the charger reduces to low level. Battery
must be removed from the charger within three days. Fully
charged battery will operate a work light for about 5 hours
continuously
Features 5331-0005
• 7 Amp hour capacity, sealed lead acid type battery.
• Taper charger.
• Safety vent opens if battery is overheated.
• Battery furnished with 1’/0.3 m power cord having female
12 Volt outlet.
• Battery pack:
5.75 lbs/2.6 kgs
6”/152.4 mm height
2-1/2”/63.5 mm width
Lighting: McGill Temporary

3-1/2”/88.9 mm length
Standard Material
• Battery case: rugged nylon with double zipper, closed cell foam
padding on the sides and bottom
• 2”/50.8 mm adjustable web belt with quick release buckle
• Two “D” rings to connect the hooks of the shoulder strap
• Shoulder strap is 60”/1524.0 mm long with 1'/0.3 m long foam
pad, adjustable strap on each end.
• Triangular “D” ring provides a place to hang your light to give
hands-free lighting.

Catalog Number
Lighting

Battery Pack
Battery pack, charger, shoulder strap, and case with belt 5331-0005
Accessories and Replacement Parts
13 Watt, 12 Volt, 1.25 Amp DC lamp (shock resistant, rough service) 5331-0006
7 Amp hour battery assembly 5331-0007

1450 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Fluorescent Industrial Extension Lights

Applications
• Compact, lightweight with hinged hooks, these fluorescent
extension lights were designed to carry and use virtually
anywhere.
Features
• Ideal for use in confined areas.
• Emanates soft, glare-free light.
• Safe and durable, these lamps remain cool to the touch.
• Outer tube protects 15, 8, or 4 Watt lamps.
• Durable, heavy-duty construction throughout.
• Low energy, long-life.
• No exposed metal parts.
Standard Materials 5330-1525 5330-0818
• Impact resistant plastic
Certifications and Compliances
• UL Listed: E59071
• UL Standard: 153
• Meets OSHA requirements
• CSA Certified: LL89639 V
• CSA Standard: C22.2 No. 12 V

Lighting: McGill Temporary


15 Watt Extension Lights
Catalog Number
with 25’/7.6m Cord with 50’/15.2m Cord
15 Watt lamp 2 -1/8”/54.1 mm dia., 22-1/2”/571.5 mm length, with SJTO yellow cord — 18/3
5330-1525 5330-1550
from 3 prong plug to ballast, 18/2 to lamp. No. F15T8/CW bulb and FS-2 starter furnished
15 Watt lamp 2 -1/8”/54.1 mm dia., 22-1/2”/571.5 mm length, with SJTW yellow cord — 16/3
5332-1525 V —
from 3 prong plug to ballast, 18/2 to lamp. No. F15T8/CW bulb and FS-2 starter furnished

4 and 8 Watt Extension Lights

Lighting
with 15'/4.6m with 22'/6.7m
18/2-SJTO Cord 18/2-SJTO Cord
4 Watt, F4T5/CW; 11”/279.4 mm overall length 5330-0411 5330-0418
8 Watt, F8T5/CW; 17”/431.8 mm overall length 5330-0811 5330-0818
8 Watt, F8T5/CW; 17”/431.8 mm overall length 5332-0825 V 5332-0818 V

Accessories and Replacement Parts


Catalog Number
Plastic shield for 5330-0411 and 5330-0418 5330-0400
Hook only for 5330-0411, -0418, -0811, and -0818 5330-0401
Plastic shield for 5330-0811 and 5330-0818 5330-0800
Plastic shield for 5330-1525 5330-1500
Hooks, plastic, set of two (2) for 5330-1525 5330-1501

V CSA Certification only..

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1451


© September 2010
High Intensity Low-Voltage Extension Lights

Features
• Compact, durable, and safe 30 Watt spot and 35 Watt flood
lights.
• Ideal for use where low-voltage and maximum illumination are
needed.
• Powerpak transformer converts 120 Vac to 12 Vac, also
available as separate item.
• Spot and flood light available with battery clips where no voltage
conversion is necessary.
• Available with battery clips where no voltage conversion is
necessary.
• Heavy-duty cords, plugs, and connectors.
• TWIST-LOK connector permits economical cord and lamp
replacement.
5329-4000
Standard Materials
• Bulb and powerpak transformer
• Secondary cord: 50’/15.2 m 16/2-SJTO
• Handle: impact-resistant plastic
• Lens: polycarbonate
Lighting: McGill Temporary

Catalog Number
with Power Pack
Transformer with Battery Clips
Complete unit with 30 W, 50,000 candle power spot bulb; 50’/15.2 m 16/2-SJTO cord and plug 5329-4000 ➊ 5329-4001 ➊
Complete unit with 35 W, 325 candle power flood bulb; 50’/15.2 m 16/2-SJTO cord and plug 5329-4010 ➋ 5329-4011 ➋

Accessories and Replacement Parts


Lighting

Catalog Number
Mini-Powerpak with 5’ 16/3-SOW primary cord 5329-0015
30 Watt spot light with 50’ 16/2-SJTO cord and TWIST-LOK connector 5329-4002 ➊
35 Watt flood light with 50’ 16/2-SJTO cord and TWIST-LOK connector 5329-4012 ➋
Plastic lens 5329-4003
Lens retaining ring 5329-4004

➊ Accommodates G.E. bulb #4405 and 4405-1.


➋ Accommodates G.E. bulb #4422.

1452 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Mini-Powerpak Low-Voltage Extension Lights

Features
• Lightweight, compact transformer converts 120 Vac to 12 Vac
lighting.
• Under 6 lbs./2.7 kgs total weight.
• Transformer potted and sealed to resist moisture.
• Fuse protected primary fuse.
• TWIST-LOK connector.
• 75 W low-voltage bulb included.
Standard Material
• Extension light
• Transformer: 3” x 3-1/2” x 7”/76.2 x 88.9 x 177.8 mm
• Power cord: 5’/1.5 m 16/3-SOW
5329-7010
Certification and Compliance
• Meets OSHA requirements

Lighting: McGill Temporary


Catalog Number
Extension Lights
Complete unit with power supply cord, Mini-Powerpak transformer
7000-G extension light with 25’/7.6 m 16/3-SJTW Cord 5329-7000
7000-RG extension light with 25’/7.6 m 16/3-SJTW Cord 5329-7010
Accessories and Replacement Parts
Mini-Powerpak with 5’/1.5 m 16/3-SOW primary cord 5329-0015
25’/7.6 m 16/3-SJTW secondary cord assy., with TWIST-LOK plug 5329-0003
75 Watt low-voltage medium base A-21 bulb 6461

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1453


© September 2010
Fluorescent Hand Lamps
Explosionproof. 13 Watt Twin Tube and 26 Watt Quad

Class I, Division 1, Groups C, D


Class II, Division 1, Groups F, G

Features
• This portable, fluorescent light features durable, heavy-duty
construction with non-metallic guard, swivel hook and handle
assembly.
• The handle holds a 125 Volt rated ballast designed to operate
on 50 or 60 Hz with recyclable thermal protection.
• “T” Number: T6.
• Easy maintenance.
• Completely watertight.
• No exposed metal parts.
• 900 lumens for 13 Watt unit.
• 1800 lumens for 26 Watt unit.
• Corrosion-resistant.
• 4”/101.6 mm outside diameter.
• 23-1/2”/596.9 mm length.
• 3-1/2 lbs/1.6 kgs.
Standard Materials
• Globe: tempered glass
5227-0006
Certifications and Compliances
• UL Listed: E43473
• UL Standard: 844
Lighting: McGill Temporary

Catalog Number
13 Watt Twin Tube Selection Chart
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included) 5227-0003
Twin tube hand lamp with out cord 5227-0006
26 Watt Quad Tube Selection Chart
Hand lamp with 50’/15.2m 16/3-SO cord (male plug not included) 5227-0007
Quad tube hand lamp with out cord 5227-0008
Lighting

1454 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Tubular Fluorescent Inspection Light
Explosionproof. 8 Watt

Class I, Division 1, Group D


Class II, Group G

Applications
• This inspection light is ideal for inspection of aircraft fuel
systems because of its narrow diameter, light weight and cool
operating temperature.
Features
• Furnished with high impact aluminum alloy guard and non-
sparking swivel hook.
• “T” Number: T5.
• Easy maintenance — only glass globe requires factory
replacement.
• 450 lumens.
• 2.5”/63.5 mm outside diameter.
• 27”/685.8 mm length.
• 3 lbs., 3 oz./1.5 kgs.
5227-0004
Certifications and Compliances
• UL Listed: E43473
• UL Standard: 844

Lighting: McGill Temporary


Catalog Number
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included) 5227-0004

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1455


© September 2010
Industrial Extension Lights
Explosionproof

Class I, Division 1, Groups C, D

Features
• This watertight portable extension light features a lightweight
aluminum alloy guard with a non-sparking swivel hook, as well
as a chemical-resistant handle and globe holder.
• High impact glass globe accepts an A-21.
• The one-piece construction of the 15 Amp, 240 Vac socket
withstands temperatures up to 360 ˚F/182 °C in service.
• “T” Number: T3A.
• Completely watertight.
• Accommodates 16/3-SO or 14/3-SO cord.
• 5”/127 mm outside diameter.
• 18-1/2”/469.9 mm length.
• 4 lbs/1.8 kgs.
Standard Materials
5227-0005
• 100 Watt rough service bulb
Certifications and Compliances
• UL Listed: E43473
• UL Standard: 844
Lighting: McGill Temporary

Catalog Number
Extension Lights
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included) 5227-0001
Hand lamp with out cord 5227-0005
Accessories and Replacement Parts
Handle assembly and lamp holder 5227-9915
Guard and globe assembly 5227-9916
Lighting

1456 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Low-Voltage, High Intensity Hand Lamp
Explosionproof

Class I, Division 1, Groups C, D

Applications
• Ideal for inspecting refinery towers, manholes, or railroad tank
cars.
Features
• This low-voltage spotlight uses a 12 Volt, PAR-36, 30 Watt,
automotive type, sealed beam high intensity lamp.
• The aluminum light guard is high impact alloy and swivel hook is
non-sparking.
• “T” Number: T3C.
• 30,000 beam candlepower.
• 1/4”/6.4 mm thick glass lens.
• Can be powered by low-voltage transformer or alternate 12 Volt
source.
• 5-1/2”/139.7 mm outside diameter.
• 16”/406.4 mm length including hook. 5227-0002
• 3 lbs/1.4 kgs.
Standard Materials
• Light guard: aluminum
Certifications and Compliances
• UL Listed: E43473

Lighting: McGill Temporary


• UL Standard: 844

Catalog Number
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included) 5227-0002

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1457


© September 2010
Incandescent Utility Lights

Applications
• Ideal for food processing plants, barns, garages, warehouses,
and workshops.
• Low cost, corrosion-resistant, enclosed utility lights, complete
with base, wiring box, and globe, are convenient to use.
Features
• Fasten directly to walls, ceilings, or structural members — no
separate outlet box required.
• Glass or plastic globes screw out for easy replacement of A-21
bulbs (not included) up to 150 Watts.
• High quality materials and sockets assure long, trouble-free
service life.
• 3-1/2”/88.9 mm diameter; 9-1/2”/241.3 mm height
• Two 5/16”/7.9 mm diameter mounting holes on 4-3/8”/111.3 606 with 1435-6 653
mm centers.
• Moisture-resistant construction with no exposed metal parts.
• Large compartment for easy wiring.
• Super strong, impact-resistant, thermoplastic mounting unit.
• For use up to 100 ˚F/38 °C ambient temperature.
• Accommodates up to 150 Watts max. domestic A-21 bulbs.
• For use with either 1/2”/12.7 mm or 3/4”/19.1 mm rigid
non-metallic conduit.
Certifications and Compliances
• UL Listed: E8646
• UL Standard: 1598
• CSA Certified: LL56247 V
• CSA Listed: C22.2 No. 250.0 V
Lighting: McGill General
Lighting

V CSA Certification only.

1458 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Incandescent Utility Lights

Wiring Compartment Supply Wire Catalog Numbers


Cubic Inch/Cubic Rating 1/2"/12.7 mm 3/4"/19.1 mm
Decimeter °F/°C Threaded Conduit Opening Threaded Conduit Opening
Utility light with glass globe
For damp locations 15/0.25 257/125 600 601
For damp locations 15/0.25 221/105 C600 V C601 V
For damp locations 12/0.20 140/60 603 604
For damp locations 12/0.20 140/60 C603 V C604 V
Sealed unit for wet locations 12/0.20 140/60 605 606
Sealed unit for wet locations 12/0.20 140/60 C605 V C606 V
Utility light with clear plastic globe ➊
For damp locations 15/0.25 257/125 640 641
For damp locations 15/0.25 221/105 C640 V C641 V
For damp locations 12/0.20 140/60 643 644
For damp locations 12/0.20 140/60 C643 V C644 V
Utility light with red plastic globe ➊
For damp locations 15/0.25 257/125 650 651
For damp locations 15/0.25 221/105 C650 V C651 V
For damp locations 12/0.20 140/60 653 654
For damp locations 12/0.20 140/60 C653 V C654 V
Accessories and Replacement Parts — Additional plastic globes see Protect-O-Globes

Lighting: McGill General


Catalog Number
Protective metal cage for glass globes only 1435-6
Base and socket only for 600, 640, and 650 610
Base and socket only for 601, 641, and 651 611
Base and socket only for 603, 643 and 653 5213-0623
Base and socket only for 604, 644 and 654 5213-0672
Base, socket, and seal assembly only for 605 5213-0637
Base, socket, and seal assembly only for 606 5213-0638
Socket only for 15 cubic inch/ 0.25 cubic decimeter wiring compartment 600-3
Socket only for 12 cubic inch/0.20 cubic decimeter wiring compartment 606-3
Lighting

Glass globe only for 600, 601, 603, and 604 - 6-11/16"/296.9 mm long 0753
Glass globe only for 605 and 606 - 6-11/16"/296.9 mm long 0753-HR ➋
Clear plastic globe only for 640, 641, 643 and 644 - 6-1/8"/6.1 mm long 649
Red plastic globe only for 650, 651, 653 and 654 - 6-1/8"/6.1 mm long 659
Green plastic globe only - 6-1/8"/6.1 mm long 669
➊ Plastic globes max. 75 Watt base-up mounting.
➋ Heat resistant globes required for wet locations.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1459


© September 2010
Fluorescent Utility Lights

Applications
• Whether the application calls for securely lighting a livestock
operation, damp barn, or even a harsh, outdoor environment,
the 22 Watt fluorescent utility light delivers energy-efficient,
trouble-free service for a variety of demanding lighting needs.
The single unit incorporates non-corrosive construction, its
own wiring compartment, and an impact-resistant thermoplastic
mounting base.
Features
• Removable globe for effortless “push-pull” relamping and
cleaning.
• Standard 0.59"/15 mm, 22 Watt quad-tube lamp provides 75%
greater energy efficiency. 600-FL22
• Average service life of 10,000 hours.
• Fastens directly to walls, ceilings, or structural members.
• 3-1/2”/88.9 mm diameter, 9-1/2”/241.3 mm height. Options
• Two 5/16”/7.9 mm diameter mounting holes on 4-3/8”/111.3
• CSA Certified versions available. Items available in a CSA
mm centers.
version will be marked with a V. Add the prefix C to the
• 22 Watt, 120 Volt PLC, 0.59"/15 mm lamp equivalent to 75 Watt
beginning of the catalog number.
incandescent.
• Delivered complete with globe, ballast, lamp, socket and wiring Certifications and Compliances
box. • UL Listed: E13761
• For use up to 100 ˚F/38 °C ambient temperature. • UL Standard: 1598
• Use with either 1/2”/12.7 mm or 3/4”/19.1 mm rigid non-metallic • CSA Certified: LL56247
conduit. • CSA Listed: C22.2 No. 250.0

Wiring Compartment Supply Wire Catalog Numbers


Cubic Inch/Cubic Rating 1/2"/12.7 mm 3/4"/19.1 mm
Decimeter °F/°C Threaded Conduit Opening Threaded Conduit Opening
Utility light with glass globe
For damp locations 12/0.20 194/90 600-FL22 601-FL22
For damp locations 12/0.20 221/105 C600-FL22 V C601-FL22 V
Sealed unit for wet locations 12/0.20 194/90 605-FL22 606-FL22
Lighting: McGill General

Sealed unit for wet locations 12/0.20 221/105 C605-FL22 V C606-FL22 V


Utility light with clear plastic prismatic globe
For damp locations 12/0.20 194/90 640-FL22 641-FL22
For damp locations 12/0.20 221/105 C640-FL22 V C641-FL22 V
Sealed unit for wet locations ➊ 12/0.20 194/90 645-FL22 646-FL22
Sealed unit for wet locations ➊ 12/0.20 221/105 C645-FL22 V C646-FL22 V
Utility light with red plastic prismatic globe
For damp locations 12/0.20 194/90 650-FL22 651-FL22
For damp locations 12/0.20 221/105 C650-FL22 V C651-FL22 V
Sealed unit for wet locations ➊ 12/0.20 194/90 655-FL22 656-FL22
Sealed unit for wet locations ➊ 12/0.20 221/105 C655-FL22 V C656-FL22 V
Accessories and Replacement Parts — Additional plastic globes see Protect-O-Globes
Lighting

Catalog Number
Glass globe only - 6-11/16”/220.7 mm long 0753
Clear plastic prismatic globe only - 8-1/4”/209.6 mm long 5213-6649
Red plastic prismatic globe only - 8-1/4”/209.6 mm long 5213-6659
Protective metal cage for glass globes only 1435-6
22 Watt, 120 Volt PLC,0.59" /15 mm lamp 5213-6660
Base, socket, and ballast assembly only for 600-FL22 5213-6623
Base, socket, ballast, and seal assembly only for 605-FL22 5213-6625
➊ For base-up operation only.
V CSA Certification only..

1460 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Protect-O-Sleeves
For Fluorescent Tubes

Applications
• Reusable Protect-O-Sleeves encase existing fluorescent tubes
to insulate and improve lighting efficiency at low temperatures.
• High tensile, polycarbonate strength protects people,
equipment, and products. 2260 (T-12)
• Available for applications requiring ultra-violet light filtering
such as museums, department stores, and art galleries, where
fluorescent lighting can deteriorate materials.
Features
• Furnished with end caps that fit snugly between lamp and
sleeve. 2270 (T-8)
• Filter Ray sleeves are designed to filter out UV rays in the range
of 0-385 nanometers when used with 400 M.A. lamps.
• Insulates lamps up to 2.5 times at 20 ˚F/-6 °C.
• Accommodates lamps up to 800 milliamps ➊.
• For use up to 100 ˚F/38 °C ambient temperature.
• Most T-8 and T-12 versions available in colors.
2546 (T-5)
Certifications and Compliances
• Meets OSHA safety requirements

T-5 Clear Protect-O-Sleeves ➋


Nominal Lamp Length Catalog Number for Sleeve with 2 Caps Box
Lamp Type Inches/Millimeters for T-5 Diameter Lamps Quantity
F-14 22/558.8 2522 48
F-21 34/863.6 2534 24
F-28 46/1168.4 2546 24

T-8 and T-12 Clear Protect-O-Sleeves ➊


Nominal Lamp Length Catalog Number for Sleeve with 2 Caps Catalog Number for Sleeve with 2 Caps Box
Lamp Type Inches/Millimeters for T-12 Diameter Lamps for T-8 Diameter Lamps Quantity
F-15 18/457.2 — 2270 24
F-20 24/609.6 2268 2278 24
F-30 36/914.4 — 2271 24

Lighting: McGill Lamp Protection


F-32 48/1219.2 — 2295 24
F-36 36/914.4 2269 — 24
F-40 48/1219.2 2260 — 24
F-40 60/1524.0 — 2286 24
F-48 46/1168.4 2261 — 24
F-60 60/1524.0 2276 — 24
F-72 72/1828.8 2262 2272 24
F-96 96/2438.4 2263 2273 24

➊ No. 2285 heat sink screens must be used with T-8 and T-12 800-milliamp maximum HO lamp bases. Two heat sink screens required per sleeve (one at each
end between lamp and sleeve). HO lamps create excessive heat at the ends. The open metal mesh of the heat sink screens spreads the excess heat over a
larger area to help eliminate deterioration of the sleeve. NOT for use with VHO lamps.
Lighting

➋ NOT for use with HO or VHO lamps.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1461


© September 2010
Protect-O-Sleeves
For Fluorescent Tubes

Clear UV Filtering Protect-O-Sleeves ➌

Nominal Catalog Number for Sleeve with 2 Caps


Lamp Length Box
Lamp Type Inches/Millimeters for T-12 Diameter Lamps for T-8 Diameter Lamps Quantity
F-32 48/1219.2 — 2295-FR 24
F-40 48/1219.2 2260-FR — 24
F-96 96/2438.4 2263-FR 2273-FR 24

Colored Protect-O-Sleeves ➊
Catalog Numbers for Sleeve with 2 Caps
Box
Lamp Type Blue Green Pink Red Yellow Quantity
F-32, T-8 2295-B 2295-G 2295-P 2295-R 2295-Y 12
F-40, T-12 2260-B 2260-G 2260-P 2260-R 2260-Y 12
F-48, T-12 2261-B 2261-G 2261-P 2261-R 2261-Y 12
F-72, T-12 2262-B 2262-G 2262-P 2262-R 2262-Y 12
F-96, T-8 2273-B 2273-G 2273-P 2273-R 2273-Y 12
F-96, T-12 2263-B 2263-G 2263-P 2263-R 2263-Y 12

Accessories and Replacement Parts


Catalog Number
Universal end cap for T-5, 2500 series 2508
Universal end cap for T-12, 2260 series 2265
Heat sink screen for HO lamp bases 2285 ➊
Universal end cap for T-8, 2270 and 2295 series sleeves produced prior to 8-1-97 2274
Universal end cap for T-8, 2270 and 2295 series sleeves produced after 8-1-97 2279
Universal T-8 filter ray end cap for 2273-FR and 2295-FR 6840
Universal T-12 filter ray end cap for 2260-FR and 2263-FR 6846
Lighting: McGill Lamp Protection

➊ No. 2285 heat sink screens must be used with T-8 and T-12 800-milliamp maximum HO lamp bases. Two heat sink screens required per sleeve (one at each
end between lamp and sleeve). HO lamps create excessive heat at the ends. The open metal mesh of the heat sink screens spreads the excess heat over a
larger area to help eliminate deterioration of the sleeve. NOT for use with VHO lamps.
Lighting

➌ Sleeves filter out ultraviolet light in the range of 0 to 385 nanometers when used with 400 M.A. lamps. NOT for use with HO or VHO Lamps.

1462 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Protect-O-Tubes
For Fluorescent Tubes

Applications
• Protect-O-Tubes offer convenient and environmentally safe
lighting for food, drug, and related industries.
Features
• Complete fluorescent lighting unit
• Adhesively attached end caps provide added safety for glass
containment.
• Air space between the lamp and sleeve acts as a cushion and
helps to protect the tube from breakage and diffuses heat.
• Improves light transmission and provides longer lamp life.
• For use up to 100 ˚F/38 °C ambient temperature.
• Available in T-8 or T-12 versions.
Standard Finish
• Lighting unit: polycarbonate sleeve, lamp, and end caps
• End caps: polypropylene
Certifications and Compliances
• Approved for use by the USDA and satisfying the requirements
of OSHA and FDA
• Meets safety requirements

Nominal Lamp Length Catalog Number Box


Lamp Type Lamp Base Inches/Millimeters of Sleeve, Lamp, and End Caps Quantity
F-15/T-8/SPX35 Med. Bi-pin 18/457.2 4230 24
F-32/T-8/SP35 Med. Bi-pin 48/1219.2 4231 24
F-32/T-8/SPX35 Med. Bi-pin 48/1219.2 4232 24
F-32/T-8/SP41 Med. Bi-pin 48/ 1219.2 4233 24
F-32/T-8/SPX41 Med. Bi-pin 48/ 1219.2 4234 24
F-40/T-12/CW/RS/WM Med. Bi-pin 48/ 1219.2 4261 24
F-40/T-12/LW/RS/WM Med. Bi-pin 48/ 1219.2 4262 24
F-40/T-12/SPX35 Med. Bi-pin 48/ 1219.2 4265 24
F-40/T-12/D Med. Bi-pin 48/ 1219.2 4266 24
F-40/T-12/WW Med. Bi-pin 48/ 1219.2 4269 24
F-48/T-12/LW/WM Single-pin 48/ 1219.2 4263 24
F-48/T-12/CW/HO Recessed Double Contact 48/ 1219.2 4264 ➊ 24

Lighting: McGill Lamp Protection


F-72/T-12/SPX35 Single-pin 72/1828.8 MCG4250 12
F-96/T-12/D Single-pin 96/2438.4 4281 12
F-96/T-12/CW/HO/WM Recessed Double Contact 96/ 2438.4 4283 ➊ 12
F-96/T-12/CW/WM Single-pin 96/ 2438.4 4284 12
F-96/T-12/D/WM Single-pin 96/ 2438.4 4285 12
F-96/T-12/WW Single-pin 96/ 2438.4 4286 12
F-96/T-12/LW/HO/WM Recessed Double Contact 96/ 2438.4 4287 ➊ 12
F-96/T-12/LW/WM Single-pin 96/ 2438.4 4288 12
F-96/T-12/SP65/HO Recessed Double Contact 96/ 2438.4 4289 ➊ 12
F-96/T-12/SP41/HO Recessed Double Contact 96/ 2438.4 4290 ➊ 12

Note: Availability of lamp types shown above may be affected by the implementation of the Energy Policy Act of 1992.
Lighting

➊ Two heat sink screens are furnished with all HO lamp styles to help eliminate excessive heat at the ends of the lamps.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1463


© September 2010
Tubeloc Holders

Applications
• Securely position and hold tubes in fluorescent fixtures
Features
• Shock resistant
• Styles to fit most fluorescent lamps in use today
Standard Finish
• Holders: shock resistant nylon
Certifications and Compliances
• UL Listed: E59240
• UL Standard: 1598
• CSA Certified: LL36636 M180
• CSA Standard: C22.2

Description Catalog Number

T-8 and T-12 Bi-pin, 14-40 Watts M175

T-12 Recessed double contact; Slimline single-pin; medium bi-pin; T-17 power
M176
groove with recessed double contact base (3/4”/19.1 mm dia. plunger)

T-17 Bi-pin mogul base M180


Lighting: McGill Lamp Protection
Lighting

1464 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Protect-O-Globes
For Incandescent Bulbs

Applications
• Protect lamps and the working environment with economical
polycarbonate globes that are virtually unbreakable.
• Ideal for the replacement of glass and wire guard combinations
where incandescent or HID lamps are used in vandal-proof
applications.
Features
• Various styles, sizes, and colors available.
• Prismatic globes provide lateral light diffusion. 1500-C 0604AP 3316
• Smooth globes reduce operating temperatures, amplify light
source.
• Accommodates up to 150 Watts maximum, base-up operation.
Certifications and Compliances
• Meets OSHA requirements

Thread Diameter Globe Dimensions Maximum Catalog


Description Color Finish In/mm Inches/Millimeters — W x L Wattage Number
Globes
8—1/4”/209.6 mm cylinder Clear Prismatic 3—1/4/82.6 3—1/2 x 8—1/4/88.9 x 209.6 60 0134CP ➊
8—1/4”/209.6 mm cylinder Clear Smooth 3—1/4/82.6 3—1/2 x 8—1/4/88.9 x 209.6 60 0134CS ➊
8—5/16”/211.1 mm cylinder Clear Smooth 4—1/4/108.0 4—3/4 x 8—5/16/120.7 x 211.1 150 1500-C
6—1/4”/158.8 mm bullet Clear Smooth 3—1/4/82.6 3—3/4 x 6—1/4/95.3 x 158.8 60 0603CS ➊
6—1/4”/158.8 mm bullet Green Smooth 3—1/4/82.6 3—3/4 x 6—1/4/95.3 x 158.8 60 0603GS ➊
6—1/4”/158.8 mm bullet Red Smooth 3—1/4/82.6 3—3/4 x 6—1/4/95.3 x 158.8 60 0603RS ➊
6—1/4”/158.8 mm bullet Amber Smooth 3—1/4/82.6 3—3/4 x 6—1/4/95.3 x 158.8 60 0603AS ➊
6—1/4”/158.8 mm cylinder Clear Smooth 3—1/4/82.6 3—1/2 x 6—1/4/95.3 x 158.8 60 0604CS ➊
6—1/4”/158.8 mm cylinder Clear Smooth 3—3/16/81.0 3—23/32 x 6/94.5 x 152.4 75 0752-C
6—1/4”/158.8 mm cylinder Green Smooth 3—1/4/82.6 3—1/2 x 6—1/4/88.9 x 158.8 60 0604GS ➊
6—1/4”/158.8 mm cylinder Red Smooth 3—1/4/82.6 3—1/2 x 6—1/4/88.9 x 158.8 60 0604RS ➊
6—1/4”/158.8 mm cylinder Amber Smooth 3—1/4/82.6 3—1/2 x 6—1/4/88.9 x 158.8 60 0604AS ➊
6—1/4”/158.8 mm cylinder Clear Prismatic 3—1/4/82.6 3—1/2 x 6—1/4/88.9 x 158.8 60 0604CP ➊
6—1/4”/158.8 mm cylinder Clear Prismatic 3—3/16/81.0 3—23/32 x 6/94.5 x 152.4 75 0752-P
6—1/4”/158.8 mm cylinder Green Prismatic 3—1/4/82.6 3—1/2 x 6—1/4/88.9 x 158.8 60 0604GP ➊
6—1/4”/158.8 mm cylinder Red Prismatic 3—1/4/82.6 3—1/2 x 6—1/4/88.9 x 158.8 60 0604RP ➊
6—1/4”/158.8 mm cylinder Amber Prismatic 3—1/4/82.6 3—1/2 x 6—1/4/88.9 x158.8 60 0604AP ➊
Bases

Lighting: McGill Lamp Protection


Yellow plastic base for use with 0752-C/P globes 3—3/16/81.0 3—7/16 x 1—5/8/87.4 x 41.4 75 3316
Yellow plastic base for use with 1500-C globe 4—1/4”/108.0 3—7/16 x 1—5/8/87.4 x 41.4 150 4014

Dimensions

A - 3-1/2”/88.9 mm A - 3-1/2”/88.9 mm
A - 3-3/4”/95.3 mm
B - 7-1/2”/190.5 mm B - 5-1/2”/139.7 mm
B - 5-1/2”/139.7 mm
C - 3.0”/76.2 mm C - 3.0”/76.2 mm
C - 3.0”/76.2 mm
D - 3-1/4”/82.6 mm D - 3-1/4”/82.6 mm
D - 3-1/4”/82.6 mm
E - 3-3/4”/95.3 mm E - 3-3/4”/95.3 mm
E - 1/2”/12.7 mm
F - 1/2”/12.7 mm F - 1/2”/12.7 mm

Cylinder Prismatic Cylinder Smooth Bullet Smooth


Lighting

➊ Can be used with McGill Incandescent and Fluorescent Utility Lights.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1465


© September 2010
Wire Lamp Guards and Wire Lamp Guard Grounding Kit

Wire Lamp Guards Wire Lamp Guard Grounding Kit


Applications Application
• Wire lamp guards with universal collars help prevent breakage • To ensure that your lamps are grounded, and comply with
and theft. NEC and OSHA requirements, the grounding kit supplies a
metal fastener and 1'/0.3 m wire to connect wire lamp guards
Features to a grounding circuit.
• A wide variety of types and sizes is available to fit your diverse
needs. Certifications and Compliances
• Heavy-duty, 10 or 12 gauge, zinc-plated construction ensures • Meets OSHA requirements
long life. • Meets NEC requirements
• Easy to install.
• Vinyl coated versions available.
• Rust-resistant zinc plating with chromate finish.
• Clamp type guards for vapor-tight fixtures available.
• Spot welded steel wire ensures long life.
Certifications and Compliances
• Meets OSHA requirements

Wire Lamp Guards

Collar Diameter Catalog Number


Description Inches/Millimeters for 100 W Bulb for 200 W Bulb

GRIPON guards with out reflectors 1.50/38.1 2100-2100-A 2200-2200-A

Vinyl coated GRIPON guards with out reflectors 1.50/38.1 V-2100BULK V-2200BULK

PROTECTOR “O” guards; open bottom heavy-duty 1.50/38.1 1433 1434

Vinyl coated PROTECTOR “O” guards 1.50/38.1 V-1433 V-1434

Trap only to close bottom of 1433 and 1434 — 2932 2933


Lighting: McGill Lamp Protection

Closed bottom wall and receptacle lamp guards 3.50/88.9 1438 —

Cage for utility light ➊ 3.50/88.9 1435-6 —

Guards for PAR and R-38 lamps 1.69/0.51 — 2.63/0.8 1438-1 —

Guards for vapor-tight fixtures 3.75/1.14 (1435-1) 1435-1 1435-3 ➋

Wire Lamp Guard Grounding Kit


Description Catalog Number

Grounding Kit 9995

➊ See McGill Incandescent and Fluorescent Utility Lights.Plastic cages available, see McGill String-O-Lights.
Lighting

➋ 300 Watt type PS25 lamp only.

1466 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Fluorescent Lamp Changers
Grips Lamp

Lighting
Applications

Lighting: McGill Lamp Changers


• Eliminate the need for climbing ladders and scaffolds.
Features
• Changers securely grip lamps for easy removal.
• Two models to choose from.
• Models for spring-loaded, bi-pin, single-pin, or recessed double
contact lamps.

174 184

Catalog Number
Lamp Changers
Complete changer unit for up to 1—1/2”/38.1 mm diameter, 4’/1.2 m lamps that require 90˚ rotation or axial movement.
Includes changer head, four zinc-plated steel pole sections each 24”/609.6 mm long, and starter changer. 174
For T-8, T-10, T-12 single-pin, T-8, T-12 med. bi-pin, and T-10, T-12 recessed double contact lamps.
Complete changer unit for 1—1/2"/38.1 mm diameter, spring-loaded lamps up to 8'/2.4 m long.
184
Includes changer head and two-section aluminum telescoping pole extending to 12—1/2’/3.8 m.
Accessories and Replacement Parts
Zinc-plated 2'/0.6 m steel pole section for 174 170-P
Zinc-plated steel changer head only for 174 171-C
Aluminum starter changer only for 174 173-S
Fluorescent changer pull cord only for 174 01540
Yellow driver, five clips, and speed nuts for 184 5274-1743

Changing Lamps is Easy With McGill Fluorescent Lamp Changers


1. First, angle changer to wedge yellow driver between lamp and socket. Then snap changer onto tube by rocking changer gently.
2. Next, standing at end of changer, push pole so driver will extract fluorescent lamp out of socket.
Model #184

Push against
Wedge In Snap on Tube Spring and extract

Wedge driver between Snap changer onto tube. Push against changer
lamp and socket. Rock changer onto lamp. spring and extract.
Lamp Identification
The changers featured on this page accommodate the fluorescent lamps at right.

Single-pin: T-8, T-10, T-12 Medium bi-pin: T-8, T-12 Recessed double contact: T-10, T-12

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1467


© September 2010
Incandescent Lamp Changers
Rubber Covered Fingers with Garter Springs
Lighting

Features
Lighting: McGill Lamp Changers

• Rubber covered fingers with garter springs make changing a


variety of lamp types simple.
• Hard-to-reach lamps are easily replaced without using ladders
or platforms.
• A variety of styles and sizes is available to fit practically all
commonly used lamps.
• Models for use with incandescent, mercury, metal halide, and
sodium lamps.
• Garter spring grips lamps firmly.
• Lightweight for ease-of-use and convenience.
• Insulated to help protect against shock.
• Changes lamps up to 25’/7.6 m height (poles sold separately).
151-CA 153-C 161-C

Lamp Size ➊ Wattage Catalog Number

Changer head with angle adjustment ➋ A-15, -17, -19; G-16-1/2,-18-1/2 15-100 150-CA

A-19, -21, -23; P-25; PS-25, -30, -35;


Changer head with angle adjustment ➋ 25-500 (18 fluorescent ➌) 151-CA
FLE-20/T-19 ➌; SL-18 ➌; G-25, -30

Changer head only PS-35, -40; G-40, -48 25-500 152-C

Changer head only PS-52; G-48, -64 750-1500 (incandescent) 153-C

1000-1500 (incandescent)
Changer head only T-16, -18, -20 154-C
400-1000 (mercury)
500-1000 (incandescent flood)
Changer head only R-52, -57 155-C
400-750 (mercury)
50-500 (incandescent)
Changer head only R-30, -40; PAR-30, -36, -38; ER-30, -40 156-C
100-175 (mercury)
400-700 (mercury)
Changer head only E-37; BT-37, -46; ED-37 158-C
400-1000 (metal halide)
750 (incandescent)
Changer head only R-60 159-C
400 (mercury flood)
75-250 (mercury)
E-21, -23, -23-1/2, -25, -28;
Changer head only 175-400 (metal halide) 161-C
ED-23-1/2, -28; BT-28
50-1000 (sodium)
50 (mercury)
Changer head only E-17, -18; ED-17, -18; B-17 35-400 (sodium) 163-C
70-175 (metal halide)

Lamp Identification
A lamp designation consists of a letter indicating the shape and a figure to identify the approximate diameter in eighths of an inch.
Lamps are measured through their greatest diameter. G-25 lamps are globe shaped with a 3-1/8”/79.5 mm diameter.

SL18 P G A T PS E/ED BT PAR R ER

➊ Lamp size, not Wattage, determines proper changer. May not accommodate weight of greater Wattage lamps.
➋ Jointed angle adapter for easy removal of horizontally or angle mounted lamps included. Use with small headed units only.
➌ Not for use with angle adapter.

1468 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Incandescent Lamp Changers
Rubber Suction Cups

Lighting
Features

Lighting: McGill Lamp Changers


• Rubber suction cups make it easy to change lamps where
space surrounding bulbs is limited.
• Made of durable synthetic rubber, these changers securely
fasten onto lamps and allow for safely changing lamps up to
25’/7.6 m heights (poles sold separately).
• For lamps with smooth face only.

157-C 162-C 166-C

Lamp Size * Wattage Catalog Number


75-1000 (incandescent spot/flood)
Changer with rubber suction cups R-40, -52, RB-52 157-C
100-400 (mercury)
25-150 (incandescent)
Changer with rubber suction cup PAR-30, -36, -38 162-C
75-100 (mercury)
Changer with rubber suction cup R-20, -30, ER-30, PAR-20 30-75 (incandescent) 166-C

* Bulb size, not Wattage, determines changer to be used. Use on smooth surface lamps only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1469


© September 2010
Lamp Changer Accessories and Replacement Parts
Lighting

Application
Lighting: McGill Lamp Changers

• Lightweight accessories and replacement parts provide a safe


and sure way to remove and replace bulbs.
Features
• For use with incandescent lamp changers, these 5’/1.5 m
insulated, interchangeable pole sections are designed for quick
assembly to desired length. Up to four poles can be securely
locked together with spring-loaded buttons.
• Broken lamp base remover has plastic shield designed to catch
fragments and help protect user. Fits 160-P lamp changer pole,
providing a fully insulated, safe, and sure way to remove bases
of broken lamps.

200 9260 160-P

Catalog Number
Interchangeable, wood insulated steel pole, 5’/1.5 m sections 160-P
Broken lamp base remover for standard and mogul lamp bases 200
Garter springs for 150-CA, 151-CA, 154-C, 161-C changer heads 7013
Garter springs for 152-C, 153-C, 156-C, 158-C changer heads 7014
Garter springs for 155-C and 159-C changer heads 7019
Spring clip and button for lamp changer poles 9260

1470 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010
Notes

Lighting
Lighting: Notes

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. 1471


© September 2010
Notes
Lighting
Lighting: Notes

1472 Visit our website at www.appletonelec.com or contact us at (800) 621-1506.


© September 2010

You might also like