Survalent Technology

Your Gateway to the Smart


Grid
Corporate Profile

Survalent Scada User Group

11/18/2011 Copyright 2010 Survalent Technology 1


Survalent Technology
The Most Trusted Supplier of Control
Room Software

11/18/2011 Copyright 2010 Survalent Technology 2


Why SCADA

Access Real-Time System Information

11/18/2011 Copyright 2010 Survalent Technology 3


Why Survalent

• Management owned
• Long manager/employee tenure
• 300+ man-years of development
• Technical support embedded with development
• Fastest growing, largest install base
• Customer retention (120/2) 2010

11/18/2011 Copyright 2010 Survalent Technology 4


Why Survalent

• Providing SCADA systems for over 45 years


• Companies that have left:
• IBM, ASW, Chrysler, Cooper Power, Leeds & Northrup,
Westinghouse, Willlowglen, QEI, CDC, Datap, CAE, Honeywell,
Feranti, TRW, Foxboro, Landis & Gyr and Rockwell
•Ownership changes:
•Tejas>Valmet>Sage Automation>Neles >Metso>Telvent
•Westronics>Harris>GE Harris>GE
•Bailey>ABB
•Landis-Gyr>Siemens
•Intellution>Emerson Electric>GE
•CAE>SNC Lavalin>GE

11/18/2011 Copyright 2010 Survalent Technology 5


History

VMS OS

1964 1980 1986 1990 1998 2001 2002 2004 2009

PDP-11/34
RSX-11M OS

ALPHA

11/18/2011 Copyright 2010 Survalent Technology 6


Our History

• Today we offer the most scalable SCADA


solution on Intel processors running on
Windows OS
• Our SCADA solution can be used from a simple
HMI all the way to a multiple redundant
SCADA / DMS / OMS / EMS system
• We are committed to the long term success of
our customers (100% customer retention)
• Largest supplier of SCADA solutions for
electric utilities in Canada and the US
11/18/2011 Copyright 2010 Survalent Technology 7
Our History

• More than 400 systems deployed in 32


countries
• It takes us anywhere between 1 – 3 years to
become a dominant player in new markets
when working with the right local partner

11/18/2011 Copyright 2010 Survalent Technology 8


Our Corporate Headquarters

11/18/2011 9
Survalent Technology Mexico

11/18/2011 10
Canada
US Customers

182, Now 225+


International
Just an Example of Our Solutions

• Client Comisión Federal de Electricidad (CFE)


Golfo Norte Distribution Division:
– City of Monterrey, Mexico (1.2 Million metered
customers)
– Quad Redundant SCADA / DMS system
– Real Time Scanning of:
• 956,643 Status Points
• 923,702 Analog Points
– 200 Communication Channels
• 70% Fiber Optic
• 30% Radio Frequency + Fiber Optic
11/18/2011 14
Just an Example of Our Solutions

• SCADA/DMS in CFE Monterrey


– Control and Monitoring of all Metro Area:
• 97 Substations
• 450 Reclosers
• 100 Capacitor Banks
• Video Surveillance directly integrated into the SCADA’s
GUI (WorldView)
• Web Server with more than 50 simultaneous users

11/18/2011 15
• SCADA/DMS in CFE Monterrey
– Flawless performance in two of the worst weather
phenomenon in the region:
• Storrm of March 18th 2008
– Sustained winds > 120 km/hr for more than 12 hours
– More than 60% of the distribution system is out of service
– More than 126,000 events were recorded by the SCADA/DMS
system
– Systems performed flawlessly allowing for the monitoring and
fast power restoration of the system
• AlexHurricane
– Similar performance during the worst weather phenomenon
ever recorded in this Division’s history

11/18/2011 16
11/18/2011 17
11/18/2011 18
11/18/2011 19
11/18/2011 20
SCADA System Applications

• SCADA system functionality:


– Quad Redundancy
– Bird’s Eye View
– Command Sequencing
– IED Control Panel
– IED Wizard
– Database Transcription
– Disturbance Data Capture

11/18/2011 21
SCADA System Applications

• System SCADA (continuation):


– Sequence of Events
– Master/Slave Alarm Hierarchy
– Event Data Recording
– Power Factor Control
– Remote Alarm Annunciation
– Switch Order Preparation

11/18/2011 22
SCADA System Applications

• System SCADA (continuation):


– SCADA Add - In
– Topology / Connectivity Processor
– Virtual RTU
– Web Server (Automated Database and Graphics
Mainstenance – web server information stays
updated just by using the SCADA system)

11/18/2011 23
SCADA System Applications

• System SCADA (continuation):


– Database replicator for Real Time, Historical end
Events information to any relational database
(Oracle, MS SQL Server, etc. – as many
connections as needed).
– Graphical User Interface (WorldView)
– Interface to Corporate GIS system

11/18/2011 24
SCADA System Applications

• System SCADA (continuation):


– Interface to Corporate Trouble Call System
– Automatic Vehicle Location System
– Lightning Detection Module
– Communication Protocols:
• DNP 3.0 Level 3 serial and TCP/IP
• IEC-61850
• ICCP client and server
• SNMP version 2

11/18/2011 25
SCADA System Applications

• System SCADA (continuation):


– Fault Detection, Isolation and Service Restoration
(FDIR)
– “WorkSpace” functionality for multiple SCADA
system monitoring and control from central
SCADA Control Center

11/18/2011 26
Sample Architecture for Typical STC SCADA System

11/18/2011 27
11/18/2011 28
11/18/2011 29
SCOUT

11/18/2011 30
• North American Electric Reliability
Corporation
– Reliability Standards
– Critical Infrastructure Protection
• STC was the first supplier to deliver systems fully
compliant with the NERC – CIP standard

11/18/2011 31
• STC software complies with all availability,
security and reliability tests required by the
NERC CIP (Critical Infrastructure Protection).
• All software releases are tested and certified
to this standard prior to being published on