0% found this document useful (0 votes)
31 views

P1F71415

This document provides technical specifications for a SIPROTEC 5 device called a 7UT82 Transf. Prot. (2 Wind.). It lists details like the firmware, I/O modules, communication options, included functions, and available function points. The device has 7 binary inputs/outputs, 8 current transformers, and protections like differential, overcurrent, thermal overload, and trip circuit supervision.

Uploaded by

Marvelryu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views

P1F71415

This document provides technical specifications for a SIPROTEC 5 device called a 7UT82 Transf. Prot. (2 Wind.). It lists details like the firmware, I/O modules, communication options, included functions, and available function points. The device has 7 binary inputs/outputs, 8 current transformers, and protections like differential, overcurrent, thermal overload, and trip circuit supervision.

Uploaded by

Marvelryu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

SIPROTEC 5 - Configuration 26.04.

2024 , 01:37:12 PM
________________________________________________________________________________________________

Device: 7UT82 Transf. Prot. (2 Wind.)

Product code

Short: P1F71415
Long: 7UT82DAAAAA00WWWW0AC041112111ABAA000000AB0HC1BD4JZ0

Technical Data:

Firmware: Without FW, latest CPU


Binary inputs: 7
Binary outputs: 7 Relays (7 Standard, 0 Fast, 0 High-Speed, 0 Power)
Current transformers: 8 for protection
Voltage transformers: 0 standard
Measuring-transducer inputs: 0 (20 mA or 10 V, fast)
0 (20 mA, standard)
0 (DC 300 V)
0 (20 mA, fast)
0 (temperature)
Housing width: 1/3 x 19''
Housing type: Flush mounting
Modules in 19" row 1: IO103, PS101, NO IO
LEDs/Push-buttons: 16 LEDs
Operation Panel: Integrated
Key switch: Without
Display type: Small display
Front Design: Standard
Power Supply: DC 110 V-250 V, AC 100 V-230 V
________________________________________________________________________________________________
1/5
SIPROTEC 5 - Configuration 26.04.2024 , 01:37:12 PM
________________________________________________________________________________________________

Communication/Plug-in modules:

Communications encryption: Normal


Integrated Ethernet port J: for DIGSI 5
Plug-in module position E: USART-AB-1EL: 1 x electric serial RS485, RJ45, applicable for serial
protocols, e.g. IEC60870-5-103, DNP3.0 etc.

Plug-in module position F: Port is available but not assembled

Functions:

Function points class: Base + 20 function points

Note on function-points class


The function-points class results from the sum of the function points of the selected functions. You can
apply these functions according to the selected function-points class. The device also allows each other
selection of functions if the sum of the required function points is within the selected function-points
class.

From Version V9.3 on the function-points class "1400+" is withdrawn. With this class function-points
exceeding the limit of 1400 were free of charge. The maximum function-points class is now 1400. If a
function-points budget of more than 1400 points is required for a device the application
Function-Point-Manager need to be applied. All function points are liable to cost.

In the engineering phase DIGSI 5 checks that the selected configuration is suitable (capable of running
in the device) before loading it to the device.

Miscellaneous:

Warranty: 5 years
Special Approvals: Without
Firmware: Without FW, latest CPU

________________________________________________________________________________________________
2/5
SIPROTEC 5 - Configuration 26.04.2024 , 01:37:12 PM
________________________________________________________________________________________________

7UT82 Transformer Differential Protection - Overview Function points calculation

(P1F71415)

Functions Free of Charge

ANSI Function Abbr. Included


Protection functions for 3-pole tripping 3-pole

37 Undercurrent I<

38 Temperature supervision θ>

49 Thermal overload protection θ, I²t

49 Thermal overload protection, user-defined characteristic θ, I²t

50HS Instantaneous high-current tripping I>>>

50/51 TD Overcurrent protection with positive-sequence current I1 I1> 20 X


(from V7.9)

50N/ 51N Overcurrent protection, ground IN>


TD
50N/ 51N Overcurrent protection, 1-phase IN>
TD
74TC Trip-circuit supervision TCS

74CC Closed-circuit supervision (from V7.9) CCS

86 Lockout

87T Transformer differential protection ΔI

87T Node Differential protection (Node protection for auto ΔI Node


transformer)
87M Motor differential protection ΔI

AFD Arc-protection (only with plug-in module ARC-CD-3FO)

Measured values - standard

Switching statistic counters

PQ-Basic measured values: THD (Total Harmonic


Distortion) and harmonics (from V8.01) THD voltage
aggregation values (from V8.40)
CFC (Standard, control)

Switching sequences function

________________________________________________________________________________________________
3/5
SIPROTEC 5 - Configuration 26.04.2024 , 01:37:12 PM
________________________________________________________________________________________________

Inrush current detection

External trip initiation

Control

Protection interface, serial

Monitoring and supervision

Fault recording of analog and binary signals

Frequency-tracking groups (from V7.8) 6X

Temperature acquisition via communication protocol

Functions with Costs

ANSI Function Abbr. Included Quantity Value Points


46 Negative-sequence I2> 0 5 0
overcurrent protection
46 Unbalanced-load protection I2² t> 0 5 0
(thermal)
49H Hot spot calculation θh, I²t 0 20 0
50/51 Overcurrent protection, phases I> 3X 0 30 0
TD

Instantaneous tripping at SOTF 0 10 0


switch onto fault
50Ns/ Sensitive ground-current INs> 0 5 0
51Ns detection for systems with
resonant or isolated neutral
systems incl. a) 3I0>, b)
admittance Y0>, c) 3I0-harm>
(from V7.8)
Intermittent ground-fault Iie> 0 20 0
protection
50BF Circuit-breaker failure CBFP 0 5 0
protection, 3-pole
50RS Circuit-breaker restrike CBRS 0 20 0
protection
87T Transformer differential ΔI 0 200 0
protection for phase angle
regulating transformer (single
core)
87N Restricted ground-fault ΔIN 0 15 0
protection
________________________________________________________________________________________________
4/5
SIPROTEC 5 - Configuration 26.04.2024 , 01:37:12 PM
________________________________________________________________________________________________

87G Generator differential ΔI 0 50 0


protection
Measured values - extended: 0 3 0
Min, Max, Avg
PQ-Basic measured values: 0 20 0
Voltage unbalance (from
V8.40)
PQ-Basic measured values: 0 30 0
Voltage variations - voltage
dips, swells and interruptions
(from V8.40)
PQ-Basic measured values: 0 10 0
TDD - Total Demand Distortion
(from V8.40)
CFC arithmetic 0 40 0
Circuit-breaker monitoring ΣIx, I²t, 2P, tO, 0 10 0
(from V9.20) tC, pole
scatter,
discepancy
Disconnector monitoring (from tO, tC 0 5 0
V9.50)
Circuit-breaker 4X 0 3 0

Disconnector/Grounding 4X 0 3 0
switch

Multiplexing of protection 0 50 0
interface
SSR Slow-scan recorder (Mod.: SSR 1X 0 40 0
from V8.80, Non-Mod.: from
V9.40)
CR Continuous recorder (Mod.: CR 1X 0 25 0
from V9.20, Non-Mod.: from
V9.40)
TR Trend recorder (Mod.: from TR 1X 0 25 0
V9.30, Non-Mod.: from V9.40)

Cyber Security: Role-Based 0 25 0


Access Control (from V7.8)
Cyber Security: IEEE 802.1x 0 10 0
based network authentication
(from V8.3)
Total: 0