Airocle 5 Series Web Brochure 1
Airocle 5 Series Web Brochure 1
INSPIRED BY
THE NATURAL
FORCES FOR
MAXIMUM
ROOF-BASED
VENTILATION
Roof
5 SERIES
VENTS & VENTILATORS
ROTARY ROOF VENTS
Previously Gyro Series
CSIRO CERTIFIED
Rotary Roof
Vents
5
SERIES
Roof
Solutions
Passive
Natural
Ventilation
The pinnacle of efficient and
effective rotary ventilation
Engineered
Design
design.
Market Leading
Performance
Ideal For
Sustainable
Building Design
The 5 Series in the pinnacle of efficient and effective
rotary ventilation design. The large surface area of
our spherical design, high coefficient of discharge and
quality fabrication from Australian materials ensures
that every vent provides the longevity and airflow
Tested and certified by
CSIRO® for airflow, fire performance your building deserves.
and weather performance
Airocle Catalogue > 5 Series 3
WAREHOUSING + STORAGE
INDUSTRIAL WORKSHOPS
SCHOOLS + EDUCATION
FACILITIES
HALLS, GYMNASIUMS +
INDOOR POOLS
DEFENCE + GOVERNMENT
BUILDINGS
ELECTRICITY SUBSTATIONS +
WATER PUMP HOUSES
Rotary Vents
5 Series
Aquatic Centre
Picton NSW
6 Airocle Catalogue > 5 Series
Performance Certification
The Flow Rate Performance Ratings for the 5 Series
Ventilators in this publication are based on formulas &
guidelines as outlined by The American Society of Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE) on
Natural Ventilation & combined with the Mechanical Effect
(of wind on ventilation rates) by wind tunnel tests.
Quality Weathertight
Engineered and manufactured in Australia using The unique corrugated blade design and precision
high quality materials, the 5 Series provides the engineering ensures that our vents are able to achieve
integrity and longevity that is vital for the success of high levels of airflow while maintaining complete
projects. With the ability to fabricate from aluminium, weather tightness. Tested by the CSIRO to AS2428.1 &
Zincalume®, Colorbond®, galvanised steel or stainless 2 (Rain and Wind), we have made sure we protect the
steel, this ventilator provides the design flexibility to integrity of your building from the elements.
meet the most demanding environments.
Head Only
MODEL (T) (O) (H) MASS CYCLONE RATED FIRE RATED
(mm) (mm) (mm) (kg) (Cat C ) (Cat D) (AS1668.1)
Overall
O Series Description
H
Height
T
Throat
ZINCALUME 4 4 4 4 4
ALUMINIUM 4 4 4 4 4
ALUMINIUM (MARINE GRADE) 4 4 4 4 4
STAINLESS STEEL 4 4 4 4 4
STAINLESS STEEL (MARINE 4 4 4 4 4
GRADE)
GALVANISED STEEL 4 4 4 4 4
Note: 5OV.1050 and 5OV.1200 models are not available in Zincalume fabrication and will be fabricated in Aluminium as standard.
NOTE: Colourbond Finish is Two Pack Vitre-coat coating, matching Colorbond® colours.
9 Airocle Catalogue > 5 Series
D D D
200
200
200
O O O
Details
Base D O H Mass
Diameter (mm) (mm) (mm) (kg) Series Description
5AV.0300 300 400 200 4.0
5AV.0350 350 470 250 4.6 5AV.xxxx Signifies transition base
5AV.0400 400 500 250 6.0
5AV.0450 450 570 300 7.6 5BV.xxxx Signifies spigot base
5AV.0500 500 620 300 9.1
5AV.0600 600 800 400 10.3 5OV.xxxx Signifies no base (Head Only)
5AV.0685 685 850 400 11.5
5AV.0760 760 910 450 12.6
5AV.0840 840 1005 450 14.3
5AV.0900 900 1100 450 16.4
5AV.1050 1050 1220 600 18.1
5AV.1200 1200 1400 600 21.4
Note: Mass is based on Zincalume fabrication. Fabrication for alternative materials will alter published mass figures. Please contact us for further details if required.
Airocle Catalogue > 5 Series 10
5AV.0300 4 4 4 X 4 4 4 4
5AV.0350 4 4 4 X 4 4 4 4
5AV.0400 4 4 4 X 4 4 4 4
5AV.0450 4 4 4 4 4 4 4 4
5AV.0500 4 4 4 4 4 4 4 4
5AV.0600 4 4 4 4 4 4 4 4
5AV.0685 4 4 4 4 4 4 4 4
5AV.0760 4 4 4 4 4 4 4 4
5AV.0840 4 4 4 4 4 4 4 4
5AV.0900 4 4 4 4 4 4 4 4
5AV.1050 4 4 4 4 4 4 4 4
5AV.1200 4 4 4 4 4 4 4 4
When ventilation is used in high cyclonic regions, it is highly reccomended and advised that vents are made
operable to close off in undesirable weather conditions.
D D D
O
H H H
O
200
200
Details
Base Model D O H Mass
(mm) (mm) (mm) (kg) Series Description
5BV.0300 300 700 100 3.2
5BV.0350 350 750 100 3.7 5AV.xxxx Signifies transition base
5BV.0400 400 800 100 4.8
5BV.0450 450 850 100 6.1 5BV.xxxx Signifies spigot base
5BV.0500 500 900 150 7.3
5BV.0600 600 1,000 150 8.2 5OV.xxxx Signifies no base (Head Only)
5BV.0685 685 1,085 175 9.2
5BV.0760 760 1,140 200 10.1
5BV.0840 840 1,240 200 11.5
5BV.0900 900 1,300 200 13.1
5BV.1050 SPIGOT BASES NOT AVAILABLE
5BV.1200 SPIGOT BASES NOT AVAILABLE
Note: Mass is based on Zincalume fabrication. Fabrication for alternative materials will alter published mass figures. Please contact us for further details if required.
Airocle Catalogue > 5 Series 12
5BV.0300 X X X X X X 4 4
5BV.0350 X X X X X X 4 4
5BV.0400 X X X X X X 4 4
5BV.0450 X X X X X X 4 4
5BV.0500 X X X X X X 4 4
5BV.0600 X X X X X X 4 4
5BV.0685 X X X X X X 4 4
5BV.0760 X X X X X X 4 4
5BV.0840 X X X X X X 4 4
5BV.0900 X X X X X X 4 4
Performance
To provide our customers with the best experience, we are working on upgrading our website to include a
new calculator that will allow you to have all relevant information in a few clicks. In the meantime, please
contact our sales team for assistance with any airflow calculations.
Inlet/Makeup Air Due to the need for makeup air, adequate inlets are essential for any
ventilation system to operate effectively. While it is recommended an inlet
ratio of 1.5 : 1 (inlet : discharge) exist, Airocle can assist in designing or
developing a ventilation system to suit custom circumstances.
Night Purge
Night flushing works by opening up the Natural Ventilation system throughout the night, to cool down the
thermal mass in a building by convection. Early in the morning before temperatures rise too far, the building
is closed and kept sealed throughout the day to prevent hot air from outside entering. During the day, the cool
mass absorbs heat from occupants and other internal loads.
DAY
NIGHT
E&OE
Airocle Catalogue > 5 Series 14
Booster fans with manual or automatic timing controls can play a fundamental role in getting the most out of
your night purge system. By overcoming the often still air during night time periods, booster fans have
successfully allowed classrooms, laboratories, halls and offices to achieve comfortable environments
throughout the day while keeping windows and doors closed, and the noise outside.
Booster Fan
Incorporating a booster fan into your 5 Series gives building designers the combination of reliable natural and
mechanical ventilation. Switch between the economy and sustainability of natural airflow and the reliability of
mechanical extraction, and embrace the cost and environmental benefits of using a truly hybrid system.
Airocle 5 Series give you the sustainability and energy efficiency of natural ventilation during normal operation
with the security and reliability and flexibility of increased airflow performance in night purge situations with the
activation of booster fans.
Higher Performance
We have focused on providing designers a high performance natural ventilation product with the ability to
reliably boost this natural force with established fan principles when required - achieving much higher air flow
rates than comparative hybrid designs.
5AV.0600/050-4
150
5AV.0450/035-4
100
5AV.0400/
030-4
50
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Incorpoating a smoke spill fan into your fire rated 5 Series gives building designers the option of reliable smoke
hazard management and natural ventilation. Switch between the economy and sustainability of natural airflow
for ventilation and the reliability of mechanical smoke extraction in the event of fire situations. The smoke spill
fans allow for increased airflow performance for smoke management during a fire with the fans triggered from
the FIP.
Note: Smoke spill fans are not to be used for general ventilation purposes. They must only used for smoke
clearance.
**All smoke spill fans are custom made to order. Should you require a hybrid system for smoke spill, please
contact Airocle**
Smoke Spill Fan Airflow @ 50Pa Motor Type Electrical kW & Amps SPLA @ 3m
5AV.0400/030-4 Supply (dB)
Note: All installation must be in accordance with Airocle’s fixing and connection details.
17 Airocle Catalogue > 5 Series
Dampers
Description
Using European designed electric actuators; the ability to open, close or restrict airflow through the ventilator
makes it perfect for summer/winter operations or link to a range of control sensors. With the ability to be
power or spring return open/close or even modulating, it provides an excellent way of controlling airflow while
remaining weathertight.
Mesh
Bird Guards, Insect Mesh, Bushfire Mesh
Keeping birds, insects, debris and fire embers from entering the ventilator is important for sensitive internal
environments and in bushfire prone zones. Our ability to incorporate a range of mesh materials and apertures
within the 5 Series ensures your building is secure.
Cyclone Rated
The 5 Series (transition base only) can be rated for up to Category D cyclone regions under AS1170 ensuring the
structural integrity and performance across all parts of Australia. This has seen the 5 Series become common
feature on buildings throughout tropical regions including mining operations and cyclone shelters.
Fire Rated
The fire rated (FR) 5 Series option gives designers the ability to use natural ventilation in
fire and smoke environments, meeting all relevant fire brigade requirements, standards
and building codes, while improving sustainablity and budget outcomes.
The fire rated (FR) 5 Series, and optional dampers and smoke spill fans are all rated for:
a) 200°C for 120 minutes FIRE TESTED
b) 300°C for 30 minutes AS/NZS1668.2 &
AS/NZS2428.4
Tested to AS1668.1-1998 part 4.8.1, the 5 Series delivers reliable smoke exhaust, greater safety for occupants,
and increases the ability for emergency services to safely access the building and fire.
Note: All installation must be in accordance with Airocle’s fixing and connection details.
Airocle Catalogue > 5 Series 19
Acoustic Dampening
Our unique Phonic acoustic dampening system can be fully integrated into the 5 Series. An efficient method
of noise attenuation, the use of ignition retardant and hydrolysis resistant insulation allows vents to reduce
noise transmission both out of and into the building, and retain their high discharge coefficient heat and smoke
ventilation properties.
Acoustic Performance
Tested to AS1045-1988 Reverberation Room.
Airflow Control
Take control of your natural ventilation system through Airocle’s range of air flow controls and sensors.
Whether it be for emergency response, safeguarding optimal internal conditions or ensuring efficient airflow
performance, the 5 Series has a range of sensors, controls and air flow dampers to ensure that your system
can achieve what you want it to.
20 Airocle Catalogue > 5 Series
A Sound Advantage
Finding a way to minimise the transmission of noise out of or into buildings while passively ventilating your
building is easy. The ability to acoustically treat the 5 Series and achieve a minimum NATA tested Sound
Transmission Class (STC) of 10 ensures that your ventilation system keeps the noise where it’s meant to be.
(Tested in NATA approved laboratary to AS119-1985 and for AS1045-1988).
Flammability Properties
UL94 After flame time ≤ 2 seconds HBF* Horizontal Burn Test for foam
FMVSS-302 Burn rate - mm/min Self Extinguishing Automotive burn rate test
*Result applies to 12mm thickness.
Airocle Catalogue > 5 Series21
Installing on Roofs
Installation is simple and quick due to each base being custom made to suit the pitch and profile
of your roof. Vents are assembled fully assembled as head and base components.
The building contractor must ensure that the vent is fitted appropriately to the roof structure and that any
internal structural supports do not impede the flow path through the vent under normal operating conditions.
Vents will be provided with a full installation manual to ensure ease of installation.
Installation details are available from Airocle on request. Please contact us on 1800 805 062 as we are more
than willing to help.
22 Airocle Catalogue > 5 Series
✓ ✓ ✓ ✖
Avoid locating ventilators directly next to each other or against surfaces which may restrict the ability for
efficient exhaust and wind effect.
How to Description
Roof ventilator(s) shall be of a rotary design incorporating a sealed bearing
Specify axle system. Design shall include all applicable dampers, accessories,
fixings and flashings. Install to manufacturers recommendations.
Size
Roof ventilator(s) shall be ____ mm in diameter and located as per
architectural drawings. Refer to architectural drawings or contact Airocle
(1800 805 062) to calculate number of ventilators required, internal and
external heat loads and air change required to maintain acceptable internal
ambient temperature, and to provide proof of adequacy of design for
purpose.
Base
Roof ventilator(s) shall be fitted with a 5AV.xxxx transition base or 5BV.xxxx
spigot base to suit the ventilator diameter.
Performance
Each roof ventilator shall be capable of achieving ____ m³/sec under ____
km/h wind speed, ____ °ΔT and ____ m effective stack height parameters
or
Each roof ventilator shall be capable of achieving _____ m³/sec under
design conditions of ____________________________________________.
Testing
Roof ventilator(s) shall be designed and made in Australia using Australian
materials. Roof ventilator(s) shall have a minimum coefficient of discharge
(Cd) of 0.70 and be tested to:
COEFFICIENT CYCLONE
OF DISCHARGE RATED
AS2428.5
Proprietary Item
5 Series Model ________________ as manufactured by Airocle
(www.airocle.com.au or 1800 805 062)
Airocle Catalogue > 5 Series24
Features
Ventilator shall incorporate:
• Internal acoustic insulation with a sound transmission class (STC) of 13
• Fire Rated construction to 200°C/120min plus 300°C/30min as per
AS1668.1
• Spring return open/close disc damper with pneumatic /240v/24v
electric/ manual control to be located in the base throat
• Spring return open/close fire rated damper with pneumatic/electric/
manual control to be located in the base throat
• Booster Fan shall be of an axial fan design located in a transition base
to ensure no throat area restriction, and be capable of achieving ______
m³/hr
• Stainless steel bush fire mesh to be located in the throat of the base
to meet AS3959 consisting of a 2.0mm aperture, 0.56mmØ, 61% open
area
• Security Mesh in 0.9mm 304 grade stainless steel with tamper resistant
screws and frame with ≥61% FOA
Disclaimer
The information contained in this work has been provided with every effort having been made to ensure accuracy and completeness. However, many of
the statements contained in the catalogue are of a general nature and no guarantee is given, nor responsibility taken by Airocle for errors or omissions
and Airocle does not accept responsibility in respect of any information or advice given in relation to or as a consequence of anything contained herein.
Purchasers should seek their own independent advice as to the suitability of the products and materials contained in the catalogue for their particular
circumstances. As Airocle are committed to ongoing product development, all dimensions, designs, specifications, descriptions, text results and exhaust
capacities represented in this catalogue are subject to change without prior written notice.
15 Redbank Place (P) 1800 805 062
Picton NSW 2571 (F) 02 4677 0558
PO Box 583 Picton info@airocle.com.au
NSW 2571 Airocle.com.au