0% found this document useful (0 votes)
10 views

Emd 2022

Electrical Machine Design Bikaner Techanical university (Rajasthan) Old paper

Uploaded by

VIKAS BHATI
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
10 views

Emd 2022

Electrical Machine Design Bikaner Techanical university (Rajasthan) Old paper

Uploaded by

VIKAS BHATI
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
Roll No. Total No. of Pages: [3 rr) 8 510605 & | B. tech. V- Sem, (Main/Back) Exam., (Academic Session 2021-2022) wa Electrical Engineering ct SEE4 — 05 Electrical Machine Design Time: 3 Hours Maximum Marks: 120 Min. Passing Marks: 42. Instructions to Candidates: Part — A: Short answer questions (up to 25 words) 10 x 2 marks = 20 marks. All ten questions are compulsory. Part - B: Analytical/Problem solving questions 5 x 8 marks = 40 marks. Candidates have to answer five questions out of seven. i Part - C: Descriptive/Analytical/Problem Solving questions 4 x 15 marks = 60 marks. Candidates have to answer four questions out of five. Schematic diagrams-must be shown wherever necessary. Any data you feel missing may suitably be ‘assumed and stated clearly. Units of quantities used/calculated must be stated clearly. Use of following supporting material is permitted during examination. (Mentioned in form No. 205) ee 2. NIL. RT-A Q.1 Write the main cause of temperature rise in electrical machine. 2] Q.2. What do you understand by rating of machines? 21 Q.3 Define short circuit ratio. 2 Q.4 What is meant by synthesis and hybrid ntethod? (21 Q5 Explain about the transformer regulation. : fea] Q.6 Define leakage reactance in poly phase machine. (21 [510605] Page 1 of 3 Q.7. What methods are used for cooling of transformers? (21 Q.8 Explain specific electric and magnetic loading. Q1 Q.9 Why do we need for bracing the end connections of turbo alternators? 2] Q.10 Give the comparison of core type and shell type transformers. (21 PART-B Q.1 Write the output equations of single and three phase transformers and explain different parameter. [8] Q2. Estimate the main core dimensions of 250KVA, 3-0, 6600/440V delta/star. 50Hz, core type transformer with following details - Stepped core for which area factor = 0.56 Space factor for window = 0.25 Voltage per turn = 21.0V Current density = 2.36 A/mm? Flux density = 1.1 Tesla [8] Q3 Explain in detail about the design factors of electrical machines. [8] Q4. Explain the difference between PMSM and BLDC machines. [8] Q.5. Explain in detail about different factor that should be considered while designing the rotor slots of squirrel cage motor. [8] Q6 Calculate the following design information for 30KW, 440V, 3-phase, 6 pole, S0Hz delta. Connected squirrel cage induction motor - (i) Main dimension of stator frame (ii) No. of turns per phase in stator winding (iii) Number of stator turns ‘Assume — specific magnetic loading = 0.48 tesla, full load efficiency = 0.88, winding factor = 0.95, specific electrié loading = 26000 ampere-conductor/m, full load power factor = 0.86. is} Q.7 Explain in detail about the core design of the transformers. (8) [510605] Page 2 of 3 PART-C Q.1_ Explain in detail about the major considerations to evolve a good design of electrical machines, (15) Q.2. Write the output equation of synchronous machines and explain in detail about different parameters. 15) Q.3 Design a3 phase water wheel alternator with following specification. . Rating of machine = 33MVA Voltage = 11 KV No. of poles = 12 Pole arc to pole pitch ratio = 0.67 Frequency = 60 Hz air gap sinusoidal type. (15) Q4. Why we need CAD analysis for the motors? Explain in detail. (15) Q5_ Explain in detail about the stator design of induction machine. 15] [510605] Page 3 of 3

You might also like