Vxrail SM
Vxrail SM
x Support Matrix
VxRail D, E, G, P, S, and V Series systems
powered by PowerEdge server platforms
VxRail Engineering
March 2024
THIS WHITE PAPER IS FOR INFORMATION/A L PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL IN/A
CCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND.
© 2016 - 2022 Dell Inc. or its subsidiaries.
NOTE: This Firmware Support Matrix contains the latest compatibility and interoperability information. If
you observe inconsistencies between this information and other VxRail documentation or references,
this document supersedes all other documentation.
VxRail rules
Information Description
All nodes in a cluster must run the same version of VxRail software
10 GbE and 1GbE networks cannot both be used for vSAN traffic
10 GbE and 25 GbE networks cannot both be used for vSAN traffic
D = D Series (1U, VxRail branded Dell PowerEdge XR2) V = V Series, includes GPUs (2U, VxRail branded Dell R730 R740xd)
E = E Series (1U, VxRail branded Dell PowerEdge R630 R640 R6515 R650) S = S Series 3.5” HDD (2U, VxRail branded Dell R730 R740xd R750)
P = P Series (2U, VxRail branded Dell PowerEdge R730 R740xd R840 R7515 R750) G = G Series (2U/4N, VxRail branded Dell C6420)
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe FH&LP 20.0.18(DK4G2) 1.4.2.0 1.2.7.0 N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57504 QP 10/25GbE SFP28 OCP 3.0 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.28.45.12(M6FF3) 4.21.71.1 N/A 4.21.71.1 N/A
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH*/LP 22.28.45.12(272HG) 4.21.71.1 N/A 4.21.71.1 N/A
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe FH&LP 20.0.18(G9GT0) 1.4.2.0 1.2.7.0 N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57504 QP 10/25GbE SFP28 OCP 3.0 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.28.45.12(M6FF3) 4.21.71.101 N/A 4.21.71.1 N/A
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH*/LP 22.28.45.12(272HG) 4.21.71.101 N/A 4.21.71.1 N/A
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.0.17(DK4G2) 1.10.9.0 1.2.7.0 N/A N/A
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe FH&LP 20.0.18(G9GT0) 1.4.2.0 1.2.7.0 N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57504 QP 10/25GbE SFP28 OCP 3.0 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 21.80.16.95(YR5N5) 218.0.38.0 N/A N/A N/A
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.28.45.12(M6FF3) 4.21.71.101 N/A 4.21.71.1 N/A
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH*/LP 22.28.45.12(272HG) 4.21.71.101 N/A 4.21.71.1 N/A
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
† ††
* Inbox driver ENS Driver RDMA Driver
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe 20.5.13 (NVXX9) 1.6.2.0 Built-in N/A N/A
FH&LP
Broadcom 5720 On-Board On-Board 21.81.3 (4JVHJ) Built-in N/A N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
FH&LP
Broadcom 57504 QP 10/25GbE SFP28 OCP 3.0 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.31.10.14 (9PNF6) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH*/LP 22.31.10.14 (0WF35) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 21.81.3 (4JVHJ) 4.1.3.2-1* N/A
21.85.21.91
BCM 57414/57412/57416 218.0.62.0 218.0.21.0! ††
(YPXWJ)
Marvell FastLinQ 41132/
15.25.11 (0NYVV) 3.40.36.0 N/A
41232/41262
16.31.10.14
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(9PNF6)
iDRAC 5.00.10.20 (YCFHY)
iSM 4.1.0 (C8YW2)
PERCCLI 7.1420.0.0 (5V7XX)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV85D)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe 20.5.13 (NVXX9) 1.6.2.0 Built-in N/A N/A
FH&LP
Broadcom 5720 On-Board On-Board 21.81.3 (4JVHJ) Built-in N/A N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
FH&LP
Broadcom 57504 QP 10/25GbE SFP28 OCP 3.0 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 21.85.21.91 (YPXWJ) 218.0.62.0 218.0.62.0 218.0.21.0 218.0.21.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.31.10.14 (9PNF6) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH*/LP 22.31.10.14 (0WF35) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 21.81.3 (4JVHJ) 4.1.3.2-1* N/A
21.85.21.91
BCM 57414/57412/57416 218.0.62.0 218.0.21.0! ††
(YPXWJ)
Marvell FastLinQ 41132/
15.25.11 (0NYVV) 3.40.36.0 N/A
41232/41262
16.31.10.14
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(9PNF6)
iDRAC 5.00.10.20 (YCFHY)
iSM 4.1.0 (C8YW2)
PERCCLI 7.1420.0.0 (5V7XX)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV85D)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Drive RoCE
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
FH&LP
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe 20.5.13 (NVXX9) 1.6.2.0 Built-in N/A N/A
FH&LP
Broadcom 5720 On-Board On-Board 21.81.3 (4JVHJ) Built-in N/A N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 21.85.21.91 (YPXWJ) 219.0.29.0 219.0.29.0 219.0.13.0 219.0.13.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 21.85.21.91 (YPXWJ) 219.0.29.0 219.0.29.0 219.0.13.0 219.0.13.0
FH&LP
Broadcom 57504 QP 10/25GbE SFP28 OCP 3.0 21.85.21.91 (YPXWJ) 219.0.29.0 219.0.29.0 219.0.13.0 219.0.13.0
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 21.85.21.91 (YPXWJ) 219.0.29.0 219.0.29.0 219.0.13.0 219.0.13.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 21.85.21.91 (YPXWJ) 219.0.29.0 219.0.29.0 219.0.13.0 219.0.13.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.31.20.06 (3CJ0V) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH*/LP 22.31.20.06 (1XPGP) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 21.81.3 (4JVHJ) 4.1.3.2-1* N/A
21.85.21.91
BCM 57414/57412/57416 219.0.29.0 219.0.13.0! ††
(YPXWJ)
Marvell FastLinQ 41132/
15.25.11 (0NYVV) 3.40.39.0 3.40.37.0! ††
41232/41262
16.31.20.06
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(3CJ0V)
iDRAC 5.00.10.20 (YCFHY)
iSM 4.1.0 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV85D)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe FH&LP 20.5.13 (NVXX9) 1.6.2.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57504 QP 10/25GbE SFP28 OCP 3.0 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH*/LP 22.32.20.04 (DNT3H) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FH&LP
Broadcom 57504/57508 QP 10/25GbE OCP 3.0 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
SFP28
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH**/LP 22.32.20.04(DNT3H) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710
20.5.13 2.1.5.0 Built-in †
(M20T0)
22.00.6
BCM 5720 4.1.3.2-1* N/A
(DFF48)
BCM 22.00.07.60
220.0.9.0 220.0.2.0! ††
57414/57412/57416/57508 (NPNT5)
Marvell FastLinQ 41132/ 15.35.06
3.40.57.0 3.40.56.0! ††
41232/41262 (7J55N)
16.32.20.04
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(0CXFK)
iDRAC 5.10.10.00 (FPTF1)
iSM 4.1.0 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV85D)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FH&LP
Broadcom 57504/57508 QP 10/25GbE OCP 3.0 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
SFP28
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH**/LP 22.32.20.04(DNT3H) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.00.6 (DFF48) 4.1.3.2-1* N/A
22.00.07.60
BCM 57414/57412/57416 220.0.9.0 220.0.2.0! ††
(NPNT5)
Marvell FastLinQ 41132/
15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
41232/41262
16.32.20.04
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(0CXFK)
iDRAC 5.10.10.00 (FPTF1)
iSM 4.1.0 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV85D)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FH&LP
Broadcom 57504/57508 QP 10/25GbE OCP 3.0 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
SFP28
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710
20.5.13 2.1.5.0 Built-in †
(M20T0)
22.00.6
BCM 5720 4.1.3.2-1* N/A
(DFF48)
BCM 22.00.07.60
220.0.9.0 220.0.2.0! ††
57414/57412/57416/57508 (NPNT5)
Marvell FastLinQ 41132/ 15.35.06
3.40.57.0 3.40.56.0! ††
41232/41262 (7J55N)
16.32.20.04
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(0CXFK)
iDRAC 5.10.30.201 (38WPW)
iSM 4.1.0.2410 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV85D)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Driver
Vendor Description Form Factor Firmware
Ethernet ENS RDMA RoCE
Intel X710 DP/QP 10GbE SFP+ OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel E810-XXV 25GbE SFP28 DP OCP 3.0, PCIe FH&LP 20.5.13 (NVXX9) 1.6.2.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57504/57508 QP 10/25GbE OCP 3.0 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
SFP28
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
6.23 7.0.400
Software Item Version Software Item Version
VxRail System 7.0.400 27701512 VMware vCenter Server ** 7.0 U3g 20150588
ESXi 7.0 U3g 20328353 Secure Remote Services No Support
VxRail Manager 7.0.400 27701512 Log Insight 8.6.2.0 19092412
ESXi 7.0 U3g (4xx) 7.0 U3g (5xx) 7.0 U3g (D/G560/F)
vSAN 7.0 U3g 7.0 U3g 7.0 U3g
BIOS 2.13.0 (74DF9) 2.14.2 (8JY6W), P580N (4417G) 2..14.2 (719W1) G560/F, (W3HTK) D560/F
FW Driver FW Driver FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.10.00* 16.17.01.00 (124X2) 17.00.10.00* 16.17.01.00 (124X2) 17.00.10.00*
16.17.01.00 (NKNVC) 17.00.10.00* 16.17.01.00
HBA330 Adapter N/A N/A 17.00.10.00*
(NKNVC) D560/F
Driver Driver Driver
NDC and NICs FW FW FW
Eth ENS Eth ENS†/RDMA††/RoCE! Eth ENS†/RDMA††/RoCE!
Intel i350 20.5.13 (HR5TP) 1.7.4.0 N/A N/A N/A 20.5.13 (HR5TP) 1.7.4.0 N/A
Intel X520/540 20.5.13 (HR5TP) 1.11.4.0 N/A N/A N/A N/A N/A
Intel X550 20.5.13 (HR5TP) 1.11.4.0 N/A 20.5.13 (HR5TP) 1.11.4.0 N/A 20.5.13 (HR5TP) 1.11.4.0 N/A
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in † 20.5.13 (M20T0) 2.1.5.0 Built-in † 20.5.13 (M20T0) 2.1.5.0 Built-in†
22.00.6 (DFF48)
BCM 5720 N/A N/A N/A N/A 4.1.3.2-1*
(D560/F)
BCM 57414/57412/57416/57508 N/A N/A 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0! †† 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0! ††
Qlogic 41112/41162/41164/41262 N/A N/A 15.35.06 (7J55N) 3.40.57.0 3.40.56.0! †† 15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
Mellanox CX4 LX N/A N/A 14.32.20.04 (PY7FC) 4.21.71.101 4.21.71.101! †† 14.32.20.04 (PY7FC) 4.21.71.101 4.21.71.101! ††
Mellanox CX5 N/A N/A 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101! †† 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101! ††
iDRAC 2.83.83.83 (DDK5R) 5.10.30.201 (38WPW) 5.10.30.201 (38WPW)
PTAgent 2.5.2.7 N/A N/A
iSM 4.1.0.2410 (C8YW2) 4.1.0.2410 (C8YW2) 4.1.0.2410 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5) 7.1910.0.0 (MRXX5) 7.1910.0.0 (MRXX5)
AEP/PMEM Firmware N/A 01.02.00.5446 (498KF) N/A
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FH&LP
Broadcom 57504/57508 QP 10/25GbE OCP 3.0 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
SFP28
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH**/LP 26.32.20.04 (DNT3H) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 LX DP 10/25Gbe SFP28 OPC 3.0 PCIe 26.32.20.04 (J2NKX) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.00.6 (DFF48) 4.1.3.2-1* N/A
22.00.07.60
BCM 57414/57412/57416 220.0.9.0 220.0.2.0! ††
(NPNT5)
Marvell FastLinQ 41132/
15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
41232/41262
16.32.20.04
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(0CXFK)
iDRAC 5.10.30.201 (38WPW)
iSM 4.1.0.2410 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
6.24 7.0.401
Software Item Version Software Item Version
VxRail System 7.0.401 27760823 VMware vCenter Server ** 7.0 U3g 20150588
ESXi 7.0 U3g 20328353 Secure Remote Services No Support
VxRail Manager 7.0.401 27760824 Log Insight 8.6.2.0 19092412
ESXi 7.0 U3g (4xx) 7.0 U3g (5xx) 7.0 U3g (D/G560/F)
vSAN 7.0 U3g 7.0 U3g 7.0 U3g
BIOS 2.13.0 (74DF9) 2.14.2 (8JY6W),P580N (4417G) 2.14.2 (25G6F) G560/F, (38PH6) D560/F
FW Driver FW Driver FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.10.00* 16.17.01.00 (124X2) 17.00.10.00* 16.17.01.00 (124X2) 17.00.10.00*
16.17.01.00 (NKNVC) 17.00.10.00* 16.17.01.00
HBA330 Adapter N/A N/A 17.00.10.00*
(NKNVC) D560/F
Driver Driver Driver
NDC and NICs FW FW FW
Eth ENS Eth ENS†/RDMA††/RoCE! Eth ENS†/RDMA††/RoCE!
Intel i350 20.5.13 (HR5TP) 1.7.4.0 N/A N/A N/A 20.5.13 (HR5TP) 1.7.4.0 N/A
Intel X520/540 20.5.13 (HR5TP) 1.11.4.0 N/A N/A N/A N/A N/A
Intel X550 20.5.13 (HR5TP) 1.11.4.0 N/A 20.5.13 (HR5TP) 1.11.4.0 N/A 20.5.13 (HR5TP) 1.11.4.0 N/A
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in † 20.5.13 (M20T0) 2.1.5.0 Built-in † 20.5.13 (M20T0) 2.1.5.0 Built-in†
22.00.6 (DFF48)
BCM 5720 N/A N/A N/A N/A 4.1.3.2-1*
(D560/F)
BCM 57414/57412/57416/57508 N/A N/A 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0! †† 22.00.07.60 (NPNT5) 220.0.9.0 220.0.2.0! ††
Qlogic 41112/41162/41164/41262 N/A N/A 15.35.06 (7J55N) 3.40.57.0 3.40.56.0! †† 15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
Mellanox CX4 LX N/A N/A 14.32.20.04 (PY7FC) 4.21.71.101 4.21.71.101! †† 14.32.20.04 (PY7FC) 4.21.71.101 4.21.71.101! ††
Mellanox CX5 N/A N/A 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101! †† 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101! ††
iDRAC 2.83.83.83 (DDK5R) 5.10.30.201 (38WPW) 5.10.30.201 (38WPW)
PTAgent 2.5.2.7 N/A N/A
iSM 4.1.0.2410 (C8YW2) 4.1.0.2410 (C8YW2) 4.1.0.2410 (C8YW2)
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FH&LP
Broadcom 57504/57508 QP 10/25GbE OCP 3.0 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
SFP28
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-5 DP 10/25GbE SFP28 OCP 3.0, PCI FH&LP 16.32.20.04 (0CXFK) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH**/LP 26.32.20.04 (DNT3H) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 LX DP 10/25Gbe SFP28 OPC 3.0 PCIe 26.32.20.04 (J2NKX) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.00.6 (DFF48) 4.1.3.2-1* N/A
22.00.07.60
BCM 57414/57412/57416 220.0.9.0 220.0.2.0! ††
(NPNT5)
Marvell FastLinQ 41132/
15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
41232/41262
16.32.20.04
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(0CXFK)
iDRAC 5.10.30.201 (38WPW)
iSM 4.1.0.2410 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FH&LP
Broadcom 57504/57508 QP 10/25GbE OCP 3.0 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
SFP28
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH**/LP 22.34.10.02 (12M67) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
Mellanox CX-6 LX DP 10/25Gbe SFP28 OPC 3.0 PCIe 26.32.20.04 (J2NKX) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.00.6 (DFF48) 4.1.3.2-1* N/A
BCM 22.21.06.80
220.0.9.0 220.0.2.0! ††
57414/57412/57416/57508 (6DN3K)
Marvell FastLinQ 41132/
15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
41232/41262
16.32.20.04
Mellanox CX5 4.21.71.101 4.21.71.101! ††
(0CXFK)
iDRAC 6.00.30.00 (D92HF)
iSM 4.1.0.2410 (C8YW2)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe 22.21.06.80 (6DN3K) 222.1.166 222.1.166 222.1.166 222.1.166
LP
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe 22.21.06.80 (6DN3K) 222.1.166 222.1.166 222.1.166 222.1.166
FH&LP
Broadcom 57504/57508 QP 10/25GbE SFP28 OCP 3.0 22.21.06.80 (6DN3K) 222.1.166 222.1.166 222.1.166 222.1.166
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FH
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Mellanox CX-6 LX DP 10/25Gbe SFP28 OPC 3.0 PCIe 26.32.20.04 (J2NKX) 4.21.71.101 4.21.71.101 4.21.71.101 4.21.71.101
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.00.6 (DFF48) 4.1.3.2-1* N/A
BCM 22.21.06.80
220.0.9.0 220.0.2.0! ††
57414/57412/57416/57508 (6DN3K)
Marvell FastLinQ 41132/
15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
41232/41262
16.32.20.04 4.21.71.10
Mellanox CX5 4.21.71.101! ††
(0CXFK) 1
iDRAC 6.00.30.00 (D92HF)
iSM 4.3.0.0.2781((X497N))
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Intel X710-T2L DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T OCP 3.0, PCIe FH&LP 20.5.13 (M20T0) 2.1.5.0 Built-in N/A N/A
Intel E810-XXV\DA4100/25GbE SFP28 DP OCP 3.0, PCIe FH&LP 20.5.13 (NVXX9) 1.6.2.0 Built-in N/A N/A
Broadcom 5720 On-Board On-Board 22.00.6 (DFF48) Built-in N/A N/A N/A
Broadcom 57412 DP 10GbE SFP+ OCP 3.0, PCIe LP 22.21.06.80 (6DN3K) 222.1.166 222.1.166 222.1.166 222.1.166
Broadcom 57416 DP 10GbE BASE-T OCP 3.0, PCIe FH&LP 22.21.06.80 (6DN3K) 222.1.166 222.1.166 222.1.166 222.1.166
Broadcom 57504/57508 QP 10/25GbE SFP28 OCP 3.0 22.21.06.80 (6DN3K) 222.1.166 222.1.166 222.1.166 222.1.166
Broadcom 57414 DP 25G SFP OCP 3.0, PCIe FH 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
Broadcom 57414 DP 10/25GbE SFP28 PCIe LP 22.00.7.60(NPNT5) 220.0.9.0 220.0.2.0 220.0.2.0 220.0.2.0
FW Driver
16.17.01.00 17.00.02.00*
HBA330 Mini
(124X2)
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.00.6 (DFF48) 4.1.3.2-1* N/A
BCM 22.21.06.80
220.0.9.0 220.0.2.0! ††
57414/57412/57416/57508 (6DN3K)
Marvell FastLinQ 41132/
15.35.06 (7J55N) 3.40.57.0 3.40.56.0! ††
41232/41262
16.32.20.04 4.21.71.10
Mellanox CX5 4.21.71.101! ††
(0CXFK) 1
iDRAC 6.00.30.00 (D92HF)
iSM 4.3.0.0.2781((X497N))
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 11
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
† †† !
* Inbox driver ENS Driver RDMA Driver RoCE
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH**/LP 22.34.10.02 (12M67) 4.21.71.101 4.22.73.100 4.22.73.100 4.22.73.100
4 4 4
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
Intel X710-T2L DP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57416 DP 10GbE BASE-T 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57504/57508 QP 10/25GbE SFP28 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57414/57454 DP 25G SFP 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57414 DP 10/25GbE SFP28 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Mellanox CX-5 DP 10/25GbE SFP28 16.35.10.12 FJ1WT) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
Mellanox CX-6 DX DP 100GbE QFSFP56 22.35.10.12 (90F25) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.02.00*
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.31.6 (XKX9M) 4.1.3.2-1* N/A
BCM
22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2! ††
57414/57412/57416/57508
BCM 57454 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2! ††
Marvell FastLinQ 41132/
16.10.00 (KXJ6Y) 3.70.7.0 3.70.7.0! ††
41232/41262
Mellanox CX5 16.35.10.12 (FJ1WT) 4.23.73.1004 4.22.73.1004! ††
iDRAC 6.10.30.20 (T9J9H)
iSM 5.1.0.0.3036 (XN8MG)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 12
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
Intel X710-T2L DP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57416 DP 10GbE BASE-T 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57504/57508 QP 10/25GbE SFP28 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57414/57454 DP 25G SFP 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57414 DP 10/25GbE SFP28 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Mellanox CX-5 DP 10/25GbE SFP28 16.35.10.12 FJ1WT) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
Mellanox CX-6 DX DP 100GbE QFSFP56 22.35.10.12 (90F25) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.02.00*
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.31.6 (XKX9M) 4.1.3.2-1* N/A
BCM
22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2! ††
57414/57412/57416/57508
BCM 57454 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2! ††
Marvell FastLinQ 41132/
16.10.00 (KXJ6Y) 3.70.7.0 3.70.7.0! ††
41232/41262
Mellanox CX5 16.35.10.12 (FJ1WT) 4.23.73.1004 4.22.73.1004! ††
iDRAC 6.10.30.20 (T9J9H)
iSM 5.1.0.0.3036 (XN8MG)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 12
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
Intel X710-T2L DP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57416 DP 10GbE BASE-T 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57504/57508 QP 10/25GbE SFP28 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57414/57454 DP 25G SFP 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Broadcom 57414 DP 10/25GbE SFP28 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2 223.0.152.2 223.0.152.2
Mellanox CX-5 DP 10/25GbE SFP28 16.35.10.12 FJ1WT) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
Mellanox CX-6 DX DP 100GbE QFSFP56 22.35.10.12 (90F25) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.02.00*
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 20.5.13 (M20T0) 2.1.5.0 Built-in †
BCM 5720 22.31.6 (XKX9M) 4.1.3.2-1* N/A
BCM
22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2! ††
57414/57412/57416/57508
BCM 57454 22.31.13.70 (8FKR1) 223.0.152.2 223.0.152.2! ††
Marvell FastLinQ 41132/
16.10.00 (KXJ6Y) 3.70.7.0 3.70.7.0! ††
41232/41262
Mellanox CX5 16.35.10.12 (FJ1WT) 4.23.73.1004 4.22.73.1004! ††
iDRAC 6.10.80.00 (Y0CWW)
iSM 5.1.0.0.3036 (XN8MG)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 12
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
Mellanox CX-6 DX DP 100GbE QFSFP56 PCIe FH**/LP 22.34.10.02 (12M67) 4.21.71.101 4.22.73.100 4.22.73.100 4.22.73.100
4 4 4
* Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
HBA355i Fnt 22.15.05.00 (2MHMF) 22.00.00.00
H755 52.21.0-4606 (RKC2R) 7.722.02.00 (8GH09)
BIOS 1.2.1 (92MT7)
iDRAC 6.0.10.39.00 (89FHD)
ISM 5.1.0.0 (XN8MG)
PM M3DMY (VE-660) DRVNW (VP-760)
BOSS-N1 2.0.13.2015 (PPF7F)
Expander BP 1.59 (G3N93)
Non-Expander BP 6.97 (M6KCM)-1U 7.03 (5TT5T)-2U
Driver
Vendor Description Firmware
Ethernet ENS RDMA RoCE
Qlogic QLE2772 FC 16.10.04 (TH9R9) 5.3.80.0 5.3.80.0 5.3.80.0 5.3.80.0
Intel X710-T2L DP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 21.5.9 (GXJ5G) 2.3.4.0 Built-in N/A N/A
Intel E810-XXV 25GbE SFP28 DP 21.5.9 (25FFJ) 1.9.8.0 Built-in N/A N/A
Intel X710-T2L DP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57416 DP 10GbE BASE-T 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57504/57508 QP 10/25GbE SFP28 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57414/57454 DP 25G SFP 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57414 DP 10/25GbE SFP28 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Mellanox CX-6 DX DP 100GbE QFSFP56 22.36.10.10 (77R8T) 4.22.73.1004 4.22.73.1004 4.22.73.1004 4.22.73.1004
Mellanox CX-6 LX DP 10/25Gbe SFP28 26.36.10.10 (453RH) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.02.00*
HBA335i Fnt /Adapter 24.15.10.00 (94P21) P580N 24.00.00 P580N
PERC H755 52.21.0-4606 (RKC2R) 7.722.02.00*
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 22.09 (9NPPG) 2.1.5.0 Built-in †
BCM 5720 22.61.7 (RG7KT) 4.1.3.2-1* N/A
BCM
22.61.10.77 (PX3JF) 226.0.245.0 223.0.152.2! ††
57414/57412/57416/57508
BCM 57454 22.61.10.77 (PX3JF) 226.0.245.0 223.0.152.2! ††
Marvell FastLinQ 41132/
16.10.00 (KXJ6Y) 3.70.7.0 3.70.7.0! ††
41232/41262
Mellanox CX5 16.35.10.12 (Y7RCC) 4.22.73.1004 4.22.73.1004! ††
iDRAC 7.00.30.00 (58YF1)
iSM 5.2.0.0 (X9MR9)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 12
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
Intel X710-T2L DP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57416 DP 10GbE BASE-T 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57504/57508 QP 10/25GbE SFP28 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57414/57454 DP 25G SFP 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57414 DP 10/25GbE SFP28 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Mellanox CX-6 DX DP 100GbE QFSFP56 22.36.10.10 (77R8T) 4.22.73.1004 4.22.73.1004 4.22.73.1004 4.22.73.1004
Mellanox CX-6 LX DP 10/25Gbe SFP28 26.36.10.10 (453RH) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.02.00*
HBA335i Fnt /Adapter 24.15.10.00 (94P21) P580N 24.00.00 P580N
PERC H755 52.21.0-4606 (RKC2R) 7.722.02.00*
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 22.09 (9NPPG) 2.1.5.0 Built-in †
BCM 5720 22.61.8 (4G8G9) 4.1.3.2-1* N/A
BCM
22.61.10.77 (PX3JF) 226.0.245.0 223.0.152.2! ††
57414/57412/57416/57508
BCM 57454 22.61.10.77 (PX3JF) 226.0.245.0 223.0.152.2! ††
Marvell FastLinQ 41132/
16.10.00 (KXJ6Y) 3.70.7.0 3.70.7.0! ††
41232/41262
Mellanox CX5 16.35.10.12 (Y7RCC) 4.22.73.1004 4.22.73.1004! ††
iDRAC 7.00.30.00 (58YF1)
iSM 5.2.0.0 (X9MR9)
PERCCLI 7.1910.0.0 (MRXX5)
PM 1.0
M.2 disk See Section 12
BOSS/SATADOM 2.5.13.3024 (3P39V)
Expander BP 2.52 (60K1J) P675F
Non-Expander BP 4.35 (VV8D5)
IDSDM N/A
Intel X710-T2L DP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57416 DP 10GbE BASE-T 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57504/57508 QP 10/25GbE SFP28 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57414/57454 DP 25G SFP 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Broadcom 57414 DP 10/25GbE SFP28 22.61.10.77 (PX3JF) 226.0.245.0 226.0.245.0 226.0.245.0 226.0.245.0
Mellanox CX-5 DP 10/25GbE SFP28 16.35.10.12 (Y7RCC) 4.22.73.1004 4.22.73.1004 4.22.73.1004 4.22.73.1004
Mellanox CX-6 DX DP 100GbE QFSFP56 22.36.10.10 (77R8T) 4.22.73.1004 4.22.73.1004 4.22.73.1004 4.22.73.1004
Mellanox CX-6 LX DP 10/25Gbe SFP28 26.36.10.10 (453RH) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.02.00*
HBA335i Fnt /Adapter 24.15.10.00 (94P21) P580N 24.00.00 P580N
PERC H755 52.21.0-4606 (RKC2R) 7.722.02.00*
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 22.09 (9NPPG) 2.1.5.0 Built-in †
BCM 5720 22.61.8 (4G8G9) 4.1.3.2-1* N/A
BCM
22.61.10.77 (PX3JF) 226.0.245.0 223.0.152.2! ††
57414/57412/57416/57508
BCM 57454 22.61.10.77 (PX3JF) 226.0.245.0 223.0.152.2! ††
Marvell FastLinQ 41132/
16.10.00 (KXJ6Y) 3.70.7.0 3.70.7.0! ††
41232/41262
Mellanox CX5 16.35.10.12 (Y7RCC) 4.22.73.1004 4.22.73.1004! ††
iDRAC 7.00.30.00 (58YF1)
iSM 5.2.0.0 (X9MR9)
Intel X710-T2L DP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Intel X710-T4L QP 10GbE BASE-T 22.09 (9NPPG) 2.3.4.0 Built-in N/A N/A
Broadcom 57412 DP 10GbE SFP+ 22.71.11.13 (3JHHP) 227.0.234.0 227.0.234.0 227.0.234.0 227.0.234.0
Broadcom 57416 DP 10GbE BASE-T 22.71.11.13 (3JHHP) 227.0.234.0 227.0.234.0 227.0.234.0 227.0.234.0
Broadcom 57504/57508 QP 10/25GbE SFP28 22.71.11.13 (3JHHP) 227.0.234.0 227.0.234.0 227.0.234.0 227.0.234.0
Broadcom 57414/57454 DP 25G SFP 22.71.11.13 (3JHHP) 227.0.234.0 227.0.234.0 227.0.234.0 227.0.234.0
Broadcom 57414 DP 10/25GbE SFP28 22.71.11.13 (3JHHP) 227.0.234.0 227.0.234.0 227.0.234.0 227.0.234.0
Mellanox CX-5 DP 10/25GbE SFP28 16.35.10.12 (Y7RCC) 4.22.73.1004 4.22.73.1004 4.22.73.1004 4.22.73.1004
Mellanox CX-6 DX DP 100GbE QFSFP56 22.36.10.10 (77R8T) 4.22.73.1004 4.22.73.1004 4.22.73.1004 4.22.73.1004
Mellanox CX-6 LX DP 10/25Gbe SFP28 26.36.10.10 (453RH) 4.23.73.1004 4.23.73.1004 4.23.73.1004 4.23.73.1004
** Mellanox CX-6 DP FH - Not supported on P670F, Supported in V670F with specific riser configuration
FW Driver
HBA330 Mini 16.17.01.00 (124X2) 17.00.02.00*
HBA335i Fnt /Adapter 24.15.10.00 (94P21) P580N 24.00.00 P580N
PERC H755 52.21.0-4606 (RKC2R) 7.722.02.00*
Driver
NDC and NICs FW
Eth ENS†/RDMA††/RoCE!
Intel X710 22.09 (9NPPG) 2.1.5.0 Built-in †
BCM 5720 22.61.8 (4G8G9) 4.1.3.2-1* N/A
BCM 22.71.11.13 (3JHHP)
227.0.234.0 223.0.152.2! ††
57414/57412/57416/57508
BCM 57454 22.71.11.13 (3JHHP) 227.0.234.0 223.0.152.2! ††
Marvell FastLinQ 41132/
16.10.00 (KXJ6Y) 3.70.7.0 3.70.7.0! ††
41232/41262
Mellanox CX5 16.35.10.12 (Y7RCC) 4.22.73.1004 4.22.73.1004! ††
iDRAC 7.00.30.00 (58YF1)
iSM 5.2.0.0 (X9MR9)
* For internal Secure Remote Services, this is the version that shipped with the release.
** 2.1.4 was never released to manufacturing and is not present on any G560/F, it will be removed from subsequent releases of the VxRail Support Matrix.
G560/F – 1.53.00.00 (MF2H1), 1.67.00.00 (CCK6H), 1.70.00.00 (PF3RM), 2.1.9 (P6CGF), 2.40 (74TRH), 2.51 (5H2H5) (Current Factory)
Notes:
1. LCM is not supported for the chassis management controller/board.
2. The CM FW is not locked in the factory for VxRail. This means that when a new CM FW version is cut-in to manufacturing, it will appear on all subsequent
G560/F systems shipped from Manufacturing as of that time.
3. Any RTW only release is not relevant as there is no LCM. Manufacturing only deploys with the versions noted in the table. CM Board updates must be done
manually to RTW releases.
IDSDM FW is “not locked” in factory. When a new FW is released, it is available for manufacturing. LCM is supported for IDSDM FW.
Date IDSDM
Release VxRail
Train Releases 1.7 1.9 1.13 2.0
RTW RTS
6/19/17 6/18/19 10/4/21 3/25/22
7.0.010 07/30/20 09/29/20 X
7.0.100 10/28/20 11/10/20 X
7.0.130 01/28/21 04/13/21 X
7.0.200 05/05/21 06/08/21 X
7.0.210 07/13/21 N/A N/A N/A
7.x
7.0.240 09/08/21 09/14/21 X (until 10/4/21) X
7.0.300 11/04/21 - X
7.0.320 02/01/22 03/15/22 X (until 3/25/22) X
7.0.350 02/24/22 X X
7.0.370 04/12/22 5/24/22 X X
IDSDM released versions - 1.7 (FF4WY), 1.9 (3N5TF), 1.13 (2NPVN), 2.0 (X4K6X) Current Factory
Notes:
1. IDSDM FW is not locked in the factory for VxRail. This means that when a new IDSDM FW version is released and available, it cuts-in to manufacturing and it
will appear in subsequent shipment.
2. LCM is supported for IDSDM and FW can be updated with VxRail RTW only releases.
3. IDSDM is supported for E560/F, P570/F, V570/F, P580N VxRail models.
* LCM is supported, but not validated for 48V DC and 380 HVDC
Guideline: LCM is supported for all subsequent 4.5.x and 4.7.x releases after the “First LCM Release”.
Guideline: LCM is supported for all subsequent 4.5.x, 4.7.x, and 7.x releases after the “First LCM Release”.
X X
NVMe/TCP,
iSCSI, NFS
PowerFlex
Supported Switches
See the chapter ‘Host Connectivity with Dell EMC Products’ for steps to connect ESXi hosts to the customer storage type in the VMware
ESX Host Connectivity Guides section of E-Lab Navigator.
Supported vSphere Virtual Storage Integrator: Dell EMC VSI E-Lab Simple Support Matrix
Dell offers a free tool to help customers manage their ESXi clusters with Dell storage arrays.
This tool can be downloaded from the dell support site. Search for VSI for VMware vSphere and download the latest version.
Notes:
• Drive Firmware is “not locked” in factory. When new Firmware is introduced in factory for any drive, it can appear with new system shipments, drive adds, or
drive replacements. A new VxRail release is not required for this new Firmware to appear in these new scenarios.
• The Min Rev column indicates that this Firmware version or higher is supported.
SSDSCKJB240G7R 240 GB Intel DC S3520 DL42 E560/F/N, P570/F, V570/F, S570, G560/F, P580N
SSDSCKKB240G8R 240 GB Intel S4510 DL6N E560/F/N, P570/F, V570/F, S570, G560/F, P580N
SSDSCKKB240GZR 240GB Intel S4520 DL70 E560/F/N, P570/F, V570/F, G560/F, P580N, S570
SSDSCKKB480G8R 480GB Intel S4510 DL6P D560/F, E665/F/N, P675F/N, E660/F, P670F, V670F
SATA M.2 SSDSCKKB480GZR 480GB Intel S4520 DL70 D560/F, E665/F/N, P675F, E660/F, V670F, P670F, P675N
MTFDDAV240TCB 240 GB Micron 5100 Pro Boot E006 E560/F/N, P570/F, V570/F, S570, G560/F, P580N,
MTFDDAV480TCB 480GB Micron 5100 Pro Boot E012 D560/F, E665/F/N, P675F/N
MTFDDAV240TDU 240 GB Micron 5300 Pro Boot J004 E560/F/N, P570/F, V570/F, S570, G560/F, P580N
MTFDDAV480TDS 480 GB Micron 5300 Pro Boot J004 D560/F, E665/F/N, P675F/N, E660/F, P670F, V670F
Notes:
• Drive Firmware is “not locked” in factory. When new Firmware is introduced in factory for any drive, it can appear with new system shipments, drive
adds, or drive replacements. A new VxRail release is not required for this new Firmware to appear in these new scenarios.
• The “Min Rev” column indicates that this Firmware version or higher is supported.
Legend:
WI = Write Intensive
MU = Mixed Use
RI = Read Intensive
New Drives/Components/Updates for this release, EOL
400GB Western Digital WI Bear Cove E560/F, P570/F, V570/F, G560/F, S570, D560/F,
DMV85 WUSTM3240BSS200 G10A
SAS SSD Quantum E665/F, P675F, E660/F, P670F, V670F
800GB HGST WI SAS SSD Bear Cove JDX4K HUSMM3280ASS200 J158 E560/F, P570/F, V570/F, S570, G560/F
800GB Western Digital WI Bear Cove E560/F, P570/F, V570/F, G560/F, S570, D560/F,
F99F6 WUSTM3280BSS200 G10A
SAS SSD Quantum E665/F, P675F
800GB HGST MU SAS Bear Cove D560/F, E560/F, E665/F, P570/F, V570/F, S570,
H07XR WUSTR6480ASS200 K953
SSD Plus G560/F
800GB Western Digital SAS BC D560/F, E560/F, E665/F, P570/F, V570/F, G560/F,
6VJC9 WUSTR6480BSS200 G101
SSD Quantum P675F
1.6TB HGST MU SAS SSD Bear Cove FDC8J HUSMR3216ASS200 J158 E560/F, P570/F, V570/F, S570, G560/F
,E660F,E660N,P670F,P670N,V670F,VP-660,VP-
3.2TB Kioxia NVMe SSD CM7 XFNX0
760,S670,E665N,P675N
660,E660F,E660N,P670F,P670N,V670F,VP-
1.6TB Kioxia NVMe SSD CM7 MP4F2
660,VP-760,S670,E665N,P675N
750GB Intel NVMe SSD P4800X DX4NF SSDPE21K750GAT E201DP31 E560/F/N, E665N, P570/F, G560/F, P580N, V570/F
1.6TB Intel NVMe SSD P5600 C9X5T SSDPF2KE016T9T 1.0.0 E560F/N, P670F, G560F, P580N, E665N, P675N
1.6TB Samsung NVMe SSD PM1725a JD6CH MZWLL1T6HEHP-000D3 1.0.4 E560/F/N, E665N, P570/F, G560/F, P580N, V570/F
1.6TB Samsung NVMe SSD PM1725b 4WDXY MZWLL1T6HAJQ-000D3 1.0.0 E560/F/N, E665N, P570/F, G560/F, P580N, V570/F
1TB Intel NVMe SSD P4510 FJ9YX SSDPE2KX010T8T VDV1DP25 E560N, E660N, E665N, P580N, P675N,
4TB Intel NVMe SSD P4510 5GMK0 SSDPE2KX040T8T VDV1DP25 E560N, E660N, E665N, P580N
15.36TB SAMSUNG RI
PM1733A D4CJG MZWLR15THBLAAD3 1.0.0 E560N, E660N, E665N, P580N, P675N
NVMe SSD
3.84TB SAMSUNG RI
PM1733A RJKM5 MZWLR3T8HCLSAD3 1.0.0 E560N, E660N, E665N, P580N, P675N
NVMe SSD
7.68TB SAMSUNG RI
PM1733A R1J8J MZWLR7T6HBLAAD3 1.0.0 E560N, E660N, E665N, P580N, P675N
NVMe SSD
6.4TB SAMSUNG MU
PM1735V2 H8D5M MZWLR6T4HALAAD3 2.0.0 E560N, E660N, E665N, P580N, P675N
NVMe SSD
3.2TB SAMSUNG MU
PM1735V2 V69W3 MZWLR3T2HBLSAD3 2.0.0 E560N, E660N, E665N, P580N, P675N
NVMe SSD
3.84TB SAMSUNG RI
PM9A3 P7G03 MZQL23T8HCLSAD3 1.0.0 E560N, E660N, E665N, P580N, P675N
NVMe SSD
1.92TB SKHynix RI SSD SE5110 962FP HFS1T9G3H2X069N DZ00 E560/F, P570/F, V570/F, G560/F
1.6TB Samsung MU SSD 1645a 3TCV6 MZILT1T6HBJR0D3 DWA3 E560/F, P570/F, G560/F, E660/F, P670F, V670F
Bear Cove
1.92TB HGST RI SAS SSD 5ND33 WUSTR1519ASS200 K953 E560/F, P570, V570/F, G560/F
Plus
8TB KIOXIA RI SAS SSD MG08 NJWMG MG08SDA800EY ASOB S570, S670
3.84TB SKHynix RI SSD SE5110 3GDK0 HFS3T8G3H2X069N DZ00 E560/F, P570/F, V570/F, G560/F
12TB 7.2K TOSHIBA SAS D560/F, E560F, E665/F, P570F, V570F, G560/F,
MG09 0N96X MG09SCA12TEY EM05
HDD P675F, E660/F, P670F, V670F
12TB 7.2K HITACHI SAS E460F, P470F, V470F, E560F, P570F, V570F,
Leo-A He12 9HXK6 HUH721212AL5200 LS08
HDD G560/F
1.2TB 10K HGST SAS HDD FJ23 / E460, P470, V470, S470
Cobra F 9XNF6/0KV02 HUC101812CSS204/HUC101812CSS200
2.5” EOL FU29 E560, P570, V570, S570, G560
1.2TB 10K Seagate SAS E460, P470, V470, S470, D560, E560, E665, P570,
Skybolt G2G54 ST1200MM0099 ST31
HDD 2.5” V570, S570, G560, E660
1.2TB 10K Toshiba SAS AL15SEB120NY E460, P470, V470, S470, D560, E560, E665, P570,
AL 15SE 01M0D EF03
HDD 2.5” V570, S570, G560, E660
Switches must meet the following requirements for VxRail 4.7 and above:
NOTE: If you plan to set up Secure Remote Services, link your Online Support account to VxRail
Manager under the same ID or it may not work properly.
• VxRail Support
•
NOTE: Additional VxRail Series information is available through the SolVe desktop tool. SolVe includes
step-by-step procedures for replacing certain hardware components, as well as other tasks.
Rule: We do not support mixing SAS/SATA SSD drives in the same disk group.
1 1 to 4
E460/E460F
2 2 to 8
1 1 to 3
2 2 to 6
P470/P470F
3 3 to 9
4 4 to 12
1 1 to 3
2 2 to 6
V470/V470F
3 3 to 9
4 4 to 12
1 1 to 6
S470
2 2 to 12
VxRail is delivered from the factory with cache and capacity disks pre-populated in specific disk slots in the chassis.
The slot location of the cache and capacity disks is important to the operation of your VxRail and should not be altered
unless directed by a Dell Technologies service professional.
C= Cache SSD
D= Capacity SSD or HDD
1 1 C D
1 2 C D D
1 3 C D D D
1 4 C D D D D
2 2 C D C D
2 3 C D D C D
2 4 C D D C D D
2 5 C D D D C D D
2 6 C D D D C D D D
2 7 C D D D D C D D D
2 8 C D D D D C D D D D
1 1 C D
1 2 C D D
1 3 C D D D
2 2 C D C D
2 3 C D D C D
2 4 C D D C D D
2 5 C D D D C D D
2 6 C D D D C D D D
3 3 C D C D C D
3 4 C D D C D C D
3 5 C D D C D D C D
3 6 C D D C D D C D D
3 7 C D D D C D D C D D
3 8 C D D D C D D D C D D
3 9 C D D D C D D D C D D D
4 4 C D C D C D C D
4 5 C D D C D C D C D
4 6 C D D C D D C D C D
4 7 C D D C D D C D D C D
4 8 C D D C D D C D D C D D
4 9 C D D D C D D C D D C D D
4 10 C D D D C D D D C D D C D D
4 11 C D D D C D D D C D D D C D D
4 12 C D D D C D D D C D D D C D D D
Drive population rules for S470
Cache Data Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10 Slot 11 Slot 12 Slot 13
1 1 D C
1 2 D D C
1 3 D D D C
1 4 D D D D C
1 5 D D D D D C
1 6 D D D D D D C
2 2 D D C C
2 3 D D D C C
2 4 D D D D C C
2 5 D D D D D C C
2 6 D D D D D D C C
2 7 D D D D D D D C C
2 8 D D D D D D D D C C
2 9 D D D D D D D D D C C
2 10 D D D D D D D D D D C C
2 11 D D D D D D D D D D D C C
2 12 D D D D D D D D D D D D C C
Disk Slot Placement Rules – E560/F/N, P570/F, V570/F, S570, P580N, G560/F
VxRail Number of Cache SSD Number of Capacity Devices
G560/G560F 1 (per node, max of 4 nodes) 1 to 5 (per node, max of 4 nodes)
1 1 to 3
D560/D560F
2 2 to 6
1 1 to 4
E560/E560F/E560N
2 2 to 8
1 1 to 5
2 2 to 10
P570/P570F
3 3 to 15
4 4 to 20
1 1 to 5
2 2 to 10
V570/V570F
3 3 to 15
4 4 to 20
1 1 to 6
S570
2 2 to 12
1 1 to 5
2 2 to 10
P580N
3 3 to 15
4 4 to 20
VxRail is delivered from the factory with cache and capacity disks pre-populated in specific disk slots in the chassis. The slot location of the cache and capacity
disks is important to the operation of VxRail and should not be altered unless directed by a Dell Technologies service professional.
C= Cache SSD
CN = Cache NVMe
D= Capacity SSD or HDD
DN= Capacity NVMe
E560/E560F
Cache (C) Data (D) Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9
1 1 D C, CN
1 2 D D C, CN
1 3 D D D C, CN
1 4 D D D D C, CN
2 2 D D C, CN C, CN
2 3 D D D C, CN C, CN
2 4 D D D D C, CN C, CN
2 5 D D D D D C, CN C, CN
2 6 D D D D D D C, CN C, CN
2 7 D D D D D D D C, CN C, CN
2 8 D D D D D D D D C, CN C, CN
P570/P570F
Cache Data Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
(C) (D) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1 1 D C, CN
1 2 D D C, CN
1 3 D D D C, CN
1 4 D D D D C, CN
1 5 D D D D D C, CN
2 2 D D C, CN C, CN
2 3 D D D C, CN C, CN
2 4 D D D D C, CN C, CN
2 5 D D D D D C, CN C, CN
2 6 D D D D D D C, CN C, CN
2 7 D D D D D D D C, CN C, CN
2 8 D D D D D D D D C, CN C, CN
2 9 D D D D D D D D D C, CN C, CN
2 10 D D D D D D D D D D C, CN C, CN
3 3 D D D C, CN C, CN C, CN
3 4 D D D D C, CN C, CN C, CN
3 5 D D D D D C, CN C, CN C, CN
3 6 D D D D D D C, CN C, CN C, CN
V570/V570F
Cache Data Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
(C) (D) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1 1 D C
1 2 D D C
1 3 D D D C
1 4 D D D D C
1 5 D D D D D C
2 2 D D C C
2 3 D D D C C
2 4 D D D D C C
2 5 D D D D D C C
2 6 D D D D D D C C
2 7 D D D D D D D C C
2 8 D D D D D D D D C C
2 9 D D D D D D D D D C C
2 10 D D D D D D D D D D C C
3 3 D D D C C C
3 4 D D D D C C C
3 5 D D D D D C C C
3 6 D D D D D D C C C
Cache Data 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11
1 1 DN CN
1 2 DN DN CN
1 3 DN DN DN CN
1 4 DN DN DN DN CN
1 5 DN DN DN DN DN CN
2 2 DN DN CN CN
2 3 DN DN DN CN CN
2 4 DN DN DN DN CN CN
2 5 DN DN DN DN DN CN CN
2 6 DN DN DN DN DN DN CN CN
2 7 DN DN DN DN DN DN DN CN CN
2 8 DN DN DN DN DN DN DN DN CN CN
2 9 DN DN DN DN DN DN DN DN DN CN CN
2 10 DN DN DN DN DN DN DN DN DN DN CN CN
3 3 DN DN DN CN CN CN
3 4 DN DN DN DN CN CN CN
3 5 DN DN DN DN DN CN CN CN
3 6 DN DN DN DN DN DN CN CN CN
3 7 DN DN DN DN DN DN DN CN CN CN
3 8 DN DN DN DN DN DN DN DN CN CN CN
3 9 DN DN DN DN DN DN DN DN DN CN CN CN
3 10 DN DN DN DN DN DN DN DN DN DN CN CN CN
3 11 DN DN DN DN DN DN DN DN DN DN DN CN CN CN
3 12 DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
3 13 DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
3 14 DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
Cache Data 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11
3 15 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
4 4 DN DN DN DN CN CN CN CN
4 5 DN DN DN DN DN CN CN CN CN
4 6 DN DN DN DN DN DN CN CN CN CN
4 7 DN DN DN DN DN DN DN CN CN CN CN
4 8 DN DN DN DN DN DN DN DN CN CN CN CN
4 9 DN DN DN DN DN DN DN DN DN CN CN CN CN
4 10 DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 11 DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 12 DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 13 DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 14 DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 15 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 16 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 17 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 18 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 19 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 20 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
D560/D560F
Cache Data
Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7
(C) (D)
1 1 D C
1 2 D D C
1 3 D D D C
2 2 D D C C
Rule: We do not support mixing SAS/SATA/NVMe SSD drives in the same disk group.
Rule: We do not support mixing capacity HDDs with capacity SSDs in the same disk group
Rule: All capacity disks to be of the same size in the same disk group.
Rule: Different disk groups can have different cache drive sizes and types within a node/server.
Rule: Different disk groups can have different capacity drive sizes and types within a node/server.
VxRail is delivered from the factory with cache and capacity disks pre-populated in specific disk slots in the chassis. The slot location of the cache and capacity disks
is important to the operation of VxRail and should not be altered unless directed by a Dell Technologies service professional.
C= Cache SSD
CN = Cache NVMe
D= Capacity SSD or HDD
DN= Capacity NVMe
Cache Data 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11
1 1 DN CN
1 2 DN DN CN
1 3 DN DN DN CN
1 4 DN DN DN DN CN
1 5 DN DN DN DN DN CN
2 2 DN DN CN CN
2 3 DN DN DN CN CN
2 4 DN DN DN DN CN CN
2 5 DN DN DN DN DN CN CN
2 6 DN DN DN DN DN DN CN CN
2 7 DN DN DN DN DN DN DN CN CN
2 8 DN DN DN DN DN DN DN DN CN CN
2 9 DN DN DN DN DN DN DN DN DN CN CN
2 10 DN DN DN DN DN DN DN DN DN DN CN CN
Cache Data 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11
3 3 DN DN DN CN CN CN
3 4 DN DN DN DN CN CN CN
3 5 DN DN DN DN DN CN CN CN
3 6 DN DN DN DN DN DN CN CN CN
3 7 DN DN DN DN DN DN DN CN CN CN
3 8 DN DN DN DN DN DN DN DN CN CN CN
3 9 DN DN DN DN DN DN DN DN DN CN CN CN
3 10 DN DN DN DN DN DN DN DN DN DN CN CN CN
3 11 DN DN DN DN DN DN DN DN DN DN DN CN CN CN
3 12 DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
3 13 DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
3 14 DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
3 15 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN
4 4 DN DN DN DN CN CN CN CN
4 5 DN DN DN DN DN CN CN CN CN
4 6 DN DN DN DN DN DN CN CN CN CN
4 7 DN DN DN DN DN DN DN CN CN CN CN
4 8 DN DN DN DN DN DN DN DN CN CN CN CN
4 9 DN DN DN DN DN DN DN DN DN CN CN CN CN
4 10 DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 11 DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 12 DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 13 DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 14 DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 15 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 16 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 17 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
Cache Data 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11
4 18 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 19 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
4 20 DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN CN CN CN CN
Disk Slot Placement Rules – E660, E660F, E660N, P670F, V670F, S670
Number of Capacity Devices per disk group
VxRail Number of disk groups Number of Cache SSD
3 4 5 6 7
1 1 - 1 to 4 - - 1 to 7
E660/E660F/E660N
2 2 - 2 to 8 - - -
1 1 - - - 1 to 6 -
2 2 - - - 2 to 12 -
P670F
3 3 - - - 3 to 18 -
4 4 - - - 4 to 24 -
1 1 - - 1 to 5 - 1 to 7
2 2 - - 2 to 10 - 2 to 14
V670F
3 3 - - 3 to 15 - 3 to 21
4 4 - - 4 to 20 - -
1 1 - - - 1 to 6 -
2 2 - - - 2 to 12 -
S670
3 3 3 to 9 - - - -
4 4 4 to 12 - - - -
VxRail is delivered from the factory with cache and capacity disks pre-populated in specific disk slots in the chassis. The slot location of the cache and
capacity disks is important to the operation of VxRail and should not be altered unless directed by a Dell Technologies service professional.
C= Cache SSD
CN = Cache NVMe
D= Capacity SSD or HDD
DN= Capacity NVMe
Cache Data 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3
1 1 D C
1 2 D D C
1 3 D D D C
1 4 D D D D C
1 5 D D D D D C
1 6 D D D D D D C
2 2 D D C C
2 3 D D D C C
2 4 D D D D C C
2 5 D D D D D C C
2 6 D D D D D D C C
2 7 D D D D D D D C C
2 8 D D D D D D D D C C
2 9 D D D D D D D D D C C
2 10 D D D D D D D D D D C C
2 11 D D D D D D D D D D D C C
2 12 D D D D D D D D D D D D C C
3 3 D D D C C C
3 4 D D D D C C C
3 5 D D D D D C C C
3 6 D D D D D D C C C
3 7 D D D D D D D C C C
3 8 D D D D D D D D C C C
3 9 D D D D D D D D D C C C
4 4 D D D D C C C C
4 5 D D D D D C C C C
Cache Data 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3
4 6 D D D D D D C C C C
4 7 D D D D D D D C C C C
4 8 D D D D D D D D C C C C
4 9 D D D D D D D D D C C C C
4 10 D D D D D D D D D D C C C C
4 11 D D D D D D D D D D D C C C C
4 12 D D D D D D D D D D D D C C C C
Cache 0 0 0 0
Data (D)
(C) Slot Slot Slot Slot
0 1 2 3
1 1 C D
1 2 C D D
1 3 C D D D
Cache Data 0 0 0 0 1 1 1 1 2 2 2 2
(C) (D) Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 0 1 2 3 0 1 2 3
1 1 C D
1 2 C D D
1 3 C D D D
2 2 C D C D
2 3 C D D C D
2 4 C D D C D D
2 5 C D D D C D D
2 6 C D D D C D D D
2 2 C D C D
2 3 C D D C D
2 4 C D D C D D
2 5 C D D D C D D
2 6 C D D D C D D D
Cache Data
Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9
(C) (D)
0 4 D D D D
0 5 D D D D D
0 6 D D D D D D
0 7 D D D D D D D
0 8 D D D D D D D D
0 9 D D D D D D D D D
0 10 D D D D D D D D D D
113 2 Y 192 128 16GB 16GB 16GB 128GB 16GB 16GB 16GB 16GB 16GB 16GB 16GB 16GB 16GB
114 2 Y 192 256 16GB 16GB 16GB 128GB 16GB 16GB 16GB 16GB 16GB 16GB 128GB 16GB 16GB 16GB
115 2 Y Y 128 512 128GB 16GB 16GB 16GB 16GB 128GB 128GB 16GB 16GB 16GB 16GB 128GB
116 2 Y 192 512 16GB 16GB 16GB 128GB 128GB 16GB 16GB 16GB 16GB 16GB 16GB 128GB 128GB 16GB 16GB 16GB
117 2 Y Y 192 1024 16GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 16GB 16GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 16GB
118 2 Y Y 192 1536 16GB 128GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 128GB 16GB 16GB 128GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 128GB 16GB
119 2 Y 384 128 32GB 32GB 32GB 128GB 32GB 32GB 32GB 32GB 32GB 32GB 32GB 32GB 32GB
120 2 Y 384 256 32GB 32GB 32GB 128GB 32GB 32GB 32GB 32GB 32GB 32GB 128GB 32GB 32GB 32GB
2 2 Y 384 512 32GB 32GB 32GB 128GB 128GB 32GB 32GB 32GB 32GB 32GB 32GB 128GB 128GB 32GB 32GB 32GB
3 2 Y 384 1024 32GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 32GB 32GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 32GB
4 2 Y Y 384 1536 32GB 128GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 128GB 32GB 32GB 128GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 128GB 32GB
6 2 Y 768 512 64GB 64GB 64GB 128GB 128GB 64GB 64GB 64GB 64GB 64GB 64GB 128GB 128GB 64GB 64GB 64GB
7 2 Y 768 1024 64GB 64GB 128GB 64GB 128GB 128GB 64GB 128GB 64GB 64GB 64GB 64GB 128GB 64GB 128GB 128GB 64GB 128GB 64GB 64GB
8 2 Y 768 1536 64GB 128GB 64GB 128GB 64GB 128GB 128GB 64GB 128GB 64GB 128GB 64GB 64GB 128GB 64GB 128GB 64GB 128GB 128GB 64GB 128GB 64GB 128GB 64GB
12 2 Y 1536 1536 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB
121 2 Y Y 192 2048 16GB 16GB 256GB 16GB 256GB 256GB 16GB 256GB 16GB 16GB 16GB 16GB 256GB 16GB 256GB 256GB 16GB 256GB 16GB 16GB
27 2 Y Y 384 2048 32GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 32GB 32GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 32GB
28 2 Y Y 384 3072 32GB 256GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 256GB 32GB 32GB 256GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 256GB 32GB
31 2 Y 768 2048 64GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 64GB 64GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 64GB
32 2 Y Y 768 3072 64GB 256GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 256GB 64GB 64GB 256GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 256GB 64GB
36 2 Y 1536 3072 128GB 256GB 128GB 256GB 128GB 256GB 256GB 128GB 256GB 128GB 256GB 128GB 128GB 256GB 128GB 256GB 128GB 256GB 256GB 128GB 256GB 128GB 256GB 128GB
“Memory mode” support requires the submission and approval of an RPQ by VMware. Legend RDIMM LRDIMM PMEM
122 4 Y Y 384 2048 16GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 16GB 16GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 16GB
123 4 Y Y 384 3072 16GB 128GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 128GB 16GB 16GB 128GB 16GB 128GB 16GB 128GB 128GB 16GB 128GB 16GB 128GB 16GB
134 4 Y 768 2048 32GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 32GB 32GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 32GB
80 4 Y Y 768 3072 32GB 128GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 128GB 32GB 32GB 128GB 32GB 128GB 32GB 128GB 128GB 32GB 128GB 32GB 128GB 32GB
84 4 Y 1536 3072 64GB 128GB 64GB 128GB 64GB 128GB 128GB 64GB 128GB 64GB 128GB 64GB 64GB 128GB 64GB 128GB 64GB 128GB 128GB 64GB 128GB 64GB 128GB 64GB
88 4 Y 3072 3072 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB 128GB
91 4 Y Y 768 8192 32GB 32GB 512GB 32GB 512GB 512GB 32GB 512GB 32GB 32GB 32GB 32GB 512GB 32GB 512GB 512GB 32GB 512GB 32GB 32GB
92 4 Y Y 768 12288 32GB 512GB 32GB 512GB 32GB 512GB 512GB 32GB 512GB 32GB 512GB 32GB 32GB 512GB 32GB 512GB 32GB 512GB 512GB 32GB 512GB 32GB 512GB 32GB
95 4 Y Y 1536 8192 64GB 64GB 512GB 64GB 512GB 512GB 64GB 512GB 64GB 64GB 64GB 64GB 512GB 64GB 512GB 512GB 64GB 512GB 64GB 64GB
96 4 Y Y 1536 12288 64GB 512GB 64GB 512GB 64GB 512GB 512GB 64GB 512GB 64GB 512GB 64GB 64GB 512GB 64GB 512GB 64GB 512GB 512GB 64GB 512GB 64GB 512GB 64GB
100 4 Y Y 3072 12288 128GB 512GB 128GB 512GB 128GB 512GB 512GB 128GB 512GB 128GB 512GB 128GB 128GB 512GB 128GB 512GB 128GB 512GB 512GB 128GB 512GB 128GB 512GB 128GB
124 4 Y Y 384 4096 16GB 16GB 256GB 16GB 256GB 256GB 16GB 256GB 16GB 16GB 16GB 16GB 256GB 16GB 256GB 256GB 16GB 256GB 16GB 16GB
125 4 Y Y 384 6144 16GB 256GB 16GB 256GB 16GB 256GB 256GB 16GB 256GB 16GB 256GB 16GB 16GB 256GB 16GB 256GB 16GB 256GB 256GB 16GB 256GB 16GB 256GB 16GB
103 4 Y Y 768 4096 32GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 32GB 32GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 32GB
104 4 Y Y 768 6144 32GB 256GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 256GB 32GB 32GB 256GB 32GB 256GB 32GB 256GB 256GB 32GB 256GB 32GB 256GB 32GB
107 4 Y 1536 4096 64GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 64GB 64GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 64GB
108 4 Y Y 1536 6144 64GB 256GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 256GB 64GB 64GB 256GB 64GB 256GB 64GB 256GB 256GB 64GB 256GB 64GB 256GB 64GB
112 4 Y 3072 6144 128GB 256GB 128GB 256GB 128GB 256GB 256GB 128GB 256GB 128GB 256GB 128GB 128GB 256GB 128GB 256GB 128GB 256GB 256GB 128GB 256GB 128GB 256GB 128GB
“Memory mode” support requires the submission and approval of an RPQ by VMware. Legend: RDIMM LRDIMM PMEM
Y B
BPS6 12+2 1/2 12 2 B R R R R R R R R R R R R
Mode CPU 1
B PMEM
R RDIMM/LRDIMM