TYPE OF VENTS
A vent connecting one or more individual vents with a vent
BRANCH VENT
stack or stack vent
A branch vent that serves two or more traps and extends from
CIRCUIT VENT in front of the last fixture
connection of a horizontal branch to the vent stack
A vent connecting at the junction of two fixture drains and
serving as a vent for both fixtures
COMMON VENT
A single vent that ventiliates multiple traps, in the case of back
to back fixture
A vertical vent that is the continuation of the drain to which
CONTINOUS VENT
the vents connect
A vent that does not serve as drain and is located where if is
DRY VENT not exposed to back up
of waste from a drainage pipe
DUAL VENT See common vent
A branch vents that performs its functions for two or more
GROUP VENT
traps
A pipe installed to vent, a fixture trap and w/c connects with
INDIVIDUAL VENT the vent system above the fixture
served or terminates in the open air
A circuit vent which loop backs to connect with a stack vent
instead of a vent stack
LOOP or CIRCUIT
Any vent connecting a horizontal branch or fixture drain
VENT
with the stack vent of the
originating waste or soil stack
Is a pipe on the fixture side of the trap through which vapor or
LOCAL VENT foul air is removed
from a room fixture
The principal artery of the venting system to which vent
MAIN VENT
branches may be connected
A vent installed so as to permit additional circulation of air
between the drainage and vent
RELIEF VENT
systems where the drainage systems might otherwise be air
bound
An arrangement of venting so installed that that one vent
UNIT VENT
pipe will serve two traps
The extension of a soil or waste stack above the highest
STACK VENT horizontal drain connected to the
stack horizontal drain, the uppermost end above the roof
WET VENT A vent which also serves as a drain
A pipe connecting upward from a soil or waste stack to a vent
YOKE VENT stack for the purpose of
preventing pressure changes in the stack
NATIONAL PLUMBING CODE OF THE PHILIPPINES
Noisy but highly efficient. Strong jet into leg forces contents
BLOW OUT
out
URINALS WALL HUNG
THROUGH
PEDESTAL
STALL
A basin like fixture design to be struddled for bathing the
BIDET
genitals and posterior parts of the body
GI PIPE SIZES 1/2", 3/4", 1", 1 1/4", 1 1/2", 2, 2 1/2", 3", 4", 6", 8", 10", 12"
NOTES
No building supply pipe shall be less than WHAT size in
19.05mm or 3/4"
diameter
Minimum height of Fire Service Connection from the
46 mm.
grade/floor
Maximum height of Fire Service Connection from the
122mm
grade/floor
Minimum height of Dry Standpipe Outlet from the floor line
61 mm.
Maximum height of Dry Standpipe Outlet from the floor line
122 mm
Considered extension of bulding drain outside the building wall
5 FEET
1/4" BEND ? Fitting for base or soil stack and building drain
51mm or 2" Wet standpipe for a riser not more than 15m
64mm or 2 1/2" Wet standpipe for riser more than 15m
4" Dry standpipe for a riser below 23m
6" Dry standpipe for a riser more than 23m
Ratio of water closets for female population for elementary and
RATIO OF 1:25
secondary school
Ratio of water closets for male population for elementary and
RATIO OF 1:30
secondary school
RATIO OF 1:75 Ratio of urinals for elementary schools
Ratio of water closets for female population for principal
RATIO OF 1:75
worship places
RATIO OF 1:5 Ratio of lavatory to number of occupants
Minimum number of water closet required for female office and
4 CLOSETS
public buildings
Minimum head of water required in section of plumbing for
3 HEADS
water test
MECHANICAL
An apparatus that can heat, cool, clean and circulate air
AIR CONDITIONER
BUGLARS AND They were deter to the intrusion alarm system in residential
PROWLERS signal system
An air passage usually formed in sheet metal with insulation for
AIR DUCT
ventilating on a building
DRAUGHT OR The current of air or gases
DRAFT
4 STOREY Requirement for a dry standpipe
BLACK Color coding of piping for fuel oil division
A hoisting and lowering mechanism with a building equipped
DUMBWAITER with relatively small car
excusively for carrying materials
The device for maintaining desirable humidity conditons in the
HUMIDIFIER
air supplied
50 GALS. The average consumption of water per capita
An automatic control of the operation of heating or cooling
THERMOSTAT device responding to changes of
temperature of the space
A tractor equipped with the blade attached by arms and bolted
BULLDOZER
to its end, used in piling earth
ACOUSTICAL LAY The acoustical ceiling board design to be laid in an exposed grid
IN PANEL suspension system
DECIBEL The total sound units provided by a given material
135-197 F Heat rating for a fixed temperature heat detector
Fire tube boliers shall be provide with sufficient room for
REAR OR TOP removal or replacement of tube
either from these places
SOUND The process of dissipating sound energy by converting it to heat
ABSORPTION
The system of deadening sound materials to wall, ceiling, floors
SOUND
to prevent sound from passing
INSULATION
through the members into adjoining room
The illuminance produce by luminous flux of the one lumen
LUX distributed uniformly over a one
square meter surface
WATER TABLE Level of subterrenean water
Package assembly of air conditioning components which
AIR HANDLING
provides for the treatment of the air
UNIT
before it is distributed to an air conditioned space
This is the criteria in selection of an elevator other than interval
TRAVEL TIME
and average waiting time
CONCRETE Protection of PVC pipe underground
CASING
CREEP Reflection of sound from curve surface
ELEVATOR
The criteria in the selection of an elevator other than interval
TRAVEL TIME
and average waiting time
FREIGHT Type of conveyor that transport packages equipment crates
ELEVATOR
Important element of an elevator below the first level floor line
BUFFER that absorbs and minimize building shocks to the car
Activate if the car travel faster than its travel speed, the power
MAGNETIC BREAK will turn off,
and grasp the rope to operate the safety gear
FOR CAR Main purpose of shafts overhead space
OVERRUN
Safety device of a passenger elevator which activates if the car
GOVERNOR travels faster than its rated speed by grasping the guide rail to
stop the car safely
A European brand
OTIS-U.S.
of elevator
A safety device of a passenger elevator which reduces the
collision shock of a car or
BUFFER
counterweight due to over travel beyond the lowest stop. It
stops the car or counterweight safely
Internal electronic safety features of an escalator. They
function as a
MONITORING
CONTACTS ON
STEP CHAIN
MONITORING
safety switches or detectors which monitors internal
CONTACTS ON
mechanical or
STEP CHAIN
electrical abnormalities and shuts down the system in any
eventuality
A passenger elevator safety device which protects the motor
CIRCUIT BREAKER and its
electrical parts from over current
During elevator emergency to rescue passenger, this type of
OUTSIDE DOOR
elevator is used to open the door
LATCH
from the outside
The elevator door components that detect the obstacle during
SAFETY SHOE the door closing and re opens
the door
WAIT INTERVAL Dividing the travel length by the rated speed
Activate by preventing the door to open during elevator car
DOOR LOCK run,
SWITCH the door elevator will open only when the car stops at the floor
Activate if the car travel faster than its travel speed, the power
MAGNETIC BREAK will turn off,
and grasp the rope to operate the safety gear
FOR CAR Main purpose of shafts overhead space
OVERRUN
Device that open and closes the electric current in an elevator
LIMIT SWITCH when it has reached the
designated end of travel course
ESCALATOR
35 degrees Minimum angle of inclination of an escalator
558 mm Minimum width of balustrade
1.20 m Maximum width of balustrade
330 mm Maximum width of the steps
TEMPERED TYPE Kind of glass required in an escalator's balustrade
GLASS
Maximum rated speed measured along the angle of inclination
38 mpm
BOILERS
R.C CONCRETE OR Provision for boiler rooms inside the building
MASONRY
3.00 mts. FROM Minimum distance if the building is not made of fire resistive
OUTSIDE WALL materials
1 meter No part of the boiler shall be closer to this from the wall
Distance of the smokestacks above the building within 50 mts.
5.00 mts
radius
Provision between any feed pump and the boiler in
2 CHECK VALVES
addition to the regular shut-off valve
NON RETURN OR Provision when two or more boilers are connected in parallel
SHUT OFF VALVE
ONE SAFETY Provision of every boiler
VALVE
TWO SAFETY Provision for boilers having generating capacity exceeding 907
VALVE kg/hr
15 DAYS Notification in writing in advance for boiler's inspection
PIPING
GALVANIZED It should not be used for steam
PIPING
STEAM DIVISION
WHITE High Pressure
BUFF Exhaust Fan
WATER DIVISION
BLUE Fresh Water, low pressure
BLUE Fresh Water, high pressure
GREEN Salt water piping
OIL DIVISION
Delivery
BRASS OR BRONZE
YELLOW Discharge
GRAY PNEUMATIC DIVISION
BLACK GAS DIVISION
BLACK FUEL OIL DIVISION
BLACK REFRIGERATING DIVISION
ELECTRICAL
The part of the cut out that is design to open or break an
CIRCUIT BREAKER electrical current under an
excessive load
WATTS Unit of power
The unit used in the measure of the rate of flow of electricity
AMPERE
OBSERVATION This is where an electric service conductor can be installed
STANDS
TOWER OR
FLATFORM
A type of electric switch consisting of one or more movable
copper blades which are hinged
KNIFE SWITCH
and which make contact with stationary forked contract jaws
being forced between them
TRANSFORMER Provision for building with an expected electric load demand of
VAULT 200KVA
The conversion of alternating current (AC) to direct current
RECTIFIER
(DC)
RAPID START
A kind of flourescent lamp that does not use starter element
FLOURESCENT
An iron box or casing by which electrical conduit branches are
JUNCTION BOX
formed
A passenger elevator with a constant 24 hour service for
5 STOREYS
residential condominum
Minimum service drop of connection line above the ground and
3.00 m
from the ground
Minimum distance of poles and transformer support located
500 mm
from the road right of way
A vertical flow of air used to separate different function of
AIR CURTAIN
spaces
GOOSENECK Original name of P-Trap
DISTRIBUTION The main feed line of an electrical circuit to which branch
LINE circuits are connected
1.20m The minimum width of door in hospital housing unit
Another type of circuit breaker element other than bolt-on
PLUG IN TYPE
COPPER WIRE The most practical conductor of electricity
RACEWAY A channel system in carrying electrical wire
An electric conductor consisting of a group of smaller diameter
CABLE WIRE conductor strands twisted
together
DISTRIBUTION Another name for power panel
PANEL
A device used to convert voltage from higher to lower or vise
TRANSFORMER
versa
NON FERROUS Metal containing no iron such as copper, brass and aluminum
METAL
The minimum allowance clearance from the highest point of
2.50m the roof to the service drop
conductor from NBC
STEP DOWN To bring down voltage
TRANSFORMER
OPEN WIRING Wiring not concealed by the building sructure
AUTOMATIC Transferring the power load from the building circuitry to
TRANSFER standby generator or during brownout
SWITCH
AIR SWITCH One with contacts that separate in air
ARC VOLTAGE The voltage across the welding arc
Cable provided in wrapping of metal usually steel wires or
ARMORED CABLE tapes, primarily for the purpose of mechanical protection
SI UNIT
HERTZ Unit of frequency equal to one cycle per seconds
PHON Unit of loudness of level
Prolongation of sound as a result of succesive reflection
REVERBERATION
WAVELENGTH Distance sounds travels during each cycles of vibration
SOUND Acoustical phenomenon which causes sound wave to bend or
DIFFRACTION scattered around
Fluctuation in pressure, a particle displaceent in elastic
SOUND
medium
PURE TONE Sound sensation in a single frequency
A luminous intensity of light expressed in candela; Unit of
CANDELA
luminous intensity
LUMINAIRE A lighting fixture
LAMBERT Unit of luminance equal to 1 candela per square meter
LUX Unit of illmination equal to one lumen per square meter
FOOT CANDLE Unit of illumination equal to one square foot
LUMINOUS FLUX Rate of flow of light through a surface
IMPEDANCE Resistance in AC system
CONDUCTANCE Reciprocal of resistance
Rate of flow of sound energy
SOUND INTENSITY
Lighting used primarily to draw attention to particular point of
ACCENT LIGHTING
interests
HPS LAMP A type of HID lamp
CONNECTIONS
SINGLE PHASE TO This connetions is used where the load is comparatively
SUPPLY 120 V small and
LIGHTING LOAD the length of the secondary circuit is short
SINGLE PHASE TO This connections is used in most urban distribution circuits
SUPPLY 120/240 3-
WIRE LIGHTING
The 120/240 volt winding is connected in series serving 240
SINGLE PHASE volts on
FOR POWER a two wire system, this connection is used for small industrial
applications
Consist merely of two single phase transformers operated
TWO PHASE 90deg out
CONNECTIONS of phase, the common wire must carry /2 times the load
current
DELTA-DELTA FOR This is used to supply a single phase lighting load and three
POWER AND phase
LIGHTING power load simultaneously
OPEN DELTA FOR This connection is used when single phase lighting load is
LIGHTING AND large as
POWER compared with the power load
Often it is desirable to increase the voltage of a circuit
Y DELTA FOR
form a 2400 to 4160 volts to
POWER
increase its potential capacity
This connection is similar to the delta-delta bank with only the
primary connection changed
The primary neutral should not be grounded or tied into the
Y DELTA FOR
system neutral, since a single
LIGHTING AND
POWER
Y DELTA FOR
LIGHTING AND
phase ground fault may result in extensive blowing of fuses
POWER
throughout the system
This connection requires special watt-hour metering
T Thermoplastic
TW Moisture Temperature Resistant
UF Underground Feeder
FEPW Flourinated Ethylene Propylene Moisture Resistant
RH Heat Resitant Rubber
RHW Heat and Moisture Resistant Rubber
RUH Heat Resistant Latex Rubber
THW Moisture and Heat Resistant Thermoplastic
THWN Heat and Moisture Resistant Thermoplstic with Nylon
XHHW Moisture and Heat Resistant Cross Link Polymer
BX Armored Cable
THHN THERMOPLASTIC HEAT RESISTANT
PE POLYETHELENE
SA SILICON ASBESTOS
AVA ASBESTOS AND VARNISH CAMBRIC
HEAT DETECTOR
FIXED Use low melting point solders or metal the expand when
TEMPERATURE exposed to heat to detect fire
HEAT DETECTOR 135deg-197deg F
Use of the scattering of light by smoke into view of photo cell
PHOTO ELECTRIC through incandescent or diode
DETECTOR
It responds to the high-frequency radiant energy from
INFRARED FLAME
flames. Alarm is only triggered when
DETECTOR
IR energy flickers at rate which is chracteristics of flame
IONIZATION Uses the interruption of small current flow between electrodes
SMOKE HEAT by smoke in ionized sampling
DETECTOR chamber to detect fire
TYPES OF CABLE
Fabricated assembly of insulated conductors enclosed in
ARMOR CABLE flexible metal sheath. It is used both on exposed and
(AC) concealed work
A factory assemble cable of one or more conductors each
individually insulated and enclosed in a mettalic sheath of
METAL CLAD interlocking tape of smooth or corrugated tube. This type of
CABLE (MC) cable is especially used for service feeders, branch circuit and
for indoor, outdoor work
Is a factory assembly of one or more conductors insulated with
highly compressed refractory mineral insulation enclosed in a
MINERAL liquid and gas tight continous copper sheath. This type of cable
INSULATED CABLE is used in dry, wet or continously moist location as service
(MI) feeders or branch circuit
UTILITIES 1999
Part of the facility which accept the house cable riser and house
TELEPHONE
the
TERMINAL
terminal block at each floor and at the highest or end of a
CABINET
feeder riser cable
Is the simplest type of building automation system, which
intercoms, PABX,
TELECOMMUNICA
microwave links, analog and digital telephone system, video
TION SYSTEM
conferencing,
satellite links, structured cabling and similar devices
A full open type valve is used in several locations in a water
ON EVERY HOSE
distribution
BIBB
system, which of the following does NOT require it?
A fireline system without a constant water supply and is
equipped with a fire service
DRY STANDPIPE
inlet and outlet connection installed exclusively for the use of
Fire Service
WATER SERVICE Term used to main water pipe delivering portable water to a
PIPE building
INSUFFICIENCY IN Which poor design in the plumbing system causes water supply
THE SIZE OF THE drop
WATER SERVICE
when the fixture is simultaneously opened?
AND
DISTRIBUTION
1 ½" KITCHEN SINK TRAP SIZE
1 ¼" LAVATORY TRAP OR BRANCH SIZE
64mm or 2 ½" OUTLET OF DRY STANDPIPE
OUTLET OF WET STANDPIPE for riser of more than 15 mts
64mm or 2 ½"
Not needed in sizing the vent pipe for individual branch and
SLOPE OF THE circuit vent
DRAIN PIPE based on the total linear footage of the pipe making up the
vent?
A hot and cold water supply pipes, where it is mix manually in
3 WAY VALVE desired water temperature
DIVERTER temperature and direct the mixed water either at the shower
head or at the fooe spout
Principle where a single lever valve used in kitchen sink and
BALL VALVE lavatory, they are
beautiful and maintenance free
Minimum water delivery in liters per minute for an outlet of a
132 LITERS PER
wet standpipe
MINUTE
at a residual pressure or 1.8 kilos per sq.mts
A female GI threaded pipe reducer fitting use to connect a
ELBOW REDUCER
reducing branch pipe at an angle
FLUSH VALVE General term used to described the fitting in the drawing
FITTINGS
2" WYE AND 2 x 1/8 GI fitting used to accept the P trap assembly of the lavatory
BEND (drawing)
Type of vent applied on installations with multi branch interval
where the vertical vent pipe
CIRCUIT VENT
takes off in front of the first fixture and connects to a main
vent stack
Stage in water purification which removes mineral deposits,
REVERSE
slats, heavy metal, totally dissolves
OSMOSIS
solids while some useful minerals are retained
FIXED Fire detector installed in a fire alarm system, which uses low
TEMPERATURE melting point
solders or metals that expand when exposed to heat to detect a
HEAT DETECTOR
fire, 135deg-197deg F
GI fitting to join two threaded fittings as close as possible but
COUPLING
not exceeding three inches
A device used to control an incoming high water pressure into
PRESSURE the water distribution system
REGULATOR by mechanical means so as to bring it to a working pressure of
80 psi
A poor venting system caused by a slow draining of water from
WRONG CHOICE
OF VENT TYPE
a fixture down a plumbing system
SUBMERSIBLE A type of pump for driven well from 150 to 200 ft which work
PUMP by a principle of venturi where
jet,jack,reciprocati water of high pressure is pump into the well to draw water
ng upwards through the return pipe
Which is not a standard size of GI pipe for water supply? 2
5"
1/2", 3",4",5"
Device in control valve which work by discharging
URINAL FLASH
instantaneous
VALVE ASSEMBLY
volume of water at higher pressure
Term used for pipe extension of not more than 2 feet in length
TAIL PIECE or install in
DEAD END any stack or branch of a plumbing rough in for the purpose of
future trap
A full open valve located in a supply pipe to every water heater
CHECK VALVE
Parking management system for two types of vehicular
deterrent either articulated arm type
AUTOMATED
or straight beam type. It can be activated by means of radio
RETRACTABLE
frequency remote control, push
PILLAR SYSTEM
push button switch, photocell, magnetic loop or acces control
MONITORING
CONTACTS ON
for BTU of heat moved per watt of electrical input energy
MONITORING Internal electronic safety features of an escalator. They
CONTACTS ON function as a
STEP CHAIN safety switches or detectors which monitors internal
mechanical or
electrical abnormalities and shuts down the system in any
eventuality
A passenger elevator safety device which protects the motor
CIRCUIT BREAKER and its
electrical parts from over current
The elevator door components that detect the obstacle during
SAFETY SHOE the door closing and re opens
the door
Mechanical equipment install on top of the main doors used to
AIR CURTAIN
retain cold in the interiors
WAIT INTERVAL Dividing the travel length by the rated speed
EVAPORATORS
Major physical restriction does a split type air conditioner
CANNOT BE
system have which restricts
LOCATED AT
its efficiency and performance
CEILING
Activate by preventing the door to open during elevator car
DOOR LOCK run,
SWITCH the door elevator will open only when the car stops at the floor
OUTSIDE DOOR Opening of door for passenger in case of power failure in the
LATCH elevator
Activate if the car travel faster than its travel speed, the power
MAGNETIC BREAK will turn off,
and grasp the rope to operate the safety gear
FOR CAR Main purpose of shafts overhead space
OVERRUN
Device that open and closes the electric current in an elevator
LIMIT SWITCH
when it has reached the
EMERGENCY designated end of travel course
SWITCH
TRAVEL SWITCH
MOTOR CONTROL
SWITCH
Coupled with central air conditioning system, used to
FAN COIL UNIT dehumidify and cool
the air stream injected into the conditioned space
A device designed to open and close a circuit by non automatic
means
and to open the circuit automatically on predetermined over
CIRCUIT BREAKER
current
CIRCUIT BREAKER
without damaged to itself when properly applied within its
rating
SERVICE The raceway that encloses the service entrance conductors
RACEWAY
A transformer connection which is ideal in the event of change
of primary
Y-Y FOR LIGHTING
voltage from 2400 volts to 4160 volts to increase the potential
AND POWER
capacity of
the system
Maximum allowed ampere rating of one chord or plug
utilization equipment connected in a 30
24 AMPERE
ampere branch circuit for lighting or utilization equipment
BUSWAYS
terminations in a completely enclosed, ventilated protective
BUSWAYS metal housing
where the system is design to carry fault current and to
withstand the
magnetic forces of such current
Standard frequency of water supply by the company like
60 CYCLES
Meralco
USE Underground Service Entrance / 75degrees
The overhead service conductor from the last pole or other
aerial support
SERVICE DROP to and including the splices, if any connecting to te service
entrance
conductors at the building
A type of nuclear reactor where the water coolant is permitted
BOILING WATER
to boil
REACTOR
within the core by operating at somewhat low pressure
In a 240V, a three phase 3-wire service, branch cicuits are
BALANCE
loaded and distributed to each
LOADING
of the three phase with this objective to attain
Unit or assembly of unit sections and associated fittings
CABLE TRAYS forming a rigid structural system
used to support cables
A transformer connection where the secondary load is a
OPEN DELTA FOR combination of
LIGHTING AND lighting and power. This connection is used when the single
POWER phase lighting
is large as compared with the power load
DELTA Y FOR A useful transformer connection applied when single phase
LIGHTING AND lighting load is
POWER all on one phase resulting into unbalanced primary
Type of flexible cable which is a fabricated assembly of
ARMOR CABLE insulated conductors
TYPE ACL which permit its use at exposed weather or excessive moisture
PUMPS
A type of pump for driven well from 150 to 200 ft which work
SUBMERSIBLE by a principle of venturi where
PUMP water of high pressure is pump into the well to draw water
upwards through the return pipe
A pump motor installed on the surface attached to a lift and
RECIPROCATING
push a rod to activate a submerge piston
A water pump for a 200ft driven well to deliver 10gpm against
JET
200ft. It is located at the surface
A pump which delivers high water discharge with high water
pressure drawn from a shallow source like cistern, best suited
CENTRIFUGAL as fire or transfer pump. The motor is placed at the surface with
shaft to turn the impellers below
A suitable type of water pump for deep well 4' or 6' casing to
JACK
deliver 35gpm against 450 ft. total develop height
ELECTRICAL
SINGLE POLE Two lights in a long hallway connected in parallel are to be
SWITCH AT controlled simultaneously at three points
START, 3-WAY
SWITCH AT
MIDPOINT AND
SINGLE POINT
SWITCH AT END
Main power supply and wiring system for 110/220 volt line;
DRAWINGS
which wiring diagram fits (drawing)
Pre requisite in use A CLEARANCE OF NOT LESS THAN 76mm SHALL BE
of split knob and MAINTAINED BETWEEN CONDUCTORS AND NOT LESS
tube wiring THAN 26mm
A branch circuit consisting of two or more grounded
MULTI WIRE conductors having a potential difference between them, and a
BRANCH CIRCUIT grounded conductor having equal potential difference between
it
What is the maximum horizontal range between two or more
6000mm to air terminal for lightning arrest for an effective disaster
7600mm prevention in building
Required minimum vertical clearance of an overhead service
drop measured from the ground over residential and comercial
5500 mm properties and driveways not subjected to truck traffic and over
600 volts to ground
Required minimum vertical clearance of an overhead service
drop measured from the ground over public streets, alleys,
roads, parking areas subjected to truck traffic, driveways on
other than residential property, and other land traveresed by
vehicular such as cultivated, grazing forest and courtyards