0% found this document useful (0 votes)
58 views3 pages

15KV Cold Shrinkable Termination Kit 3 Core

15KV cold shrinkable termination kit 3 core

Uploaded by

Juan Adrianzen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
58 views3 pages

15KV Cold Shrinkable Termination Kit 3 Core

15KV cold shrinkable termination kit 3 core

Uploaded by

Juan Adrianzen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
Installation instruction {for cold shrinkable type power cable accessories {(20Kv)25KV cold shrinkable cable accessories products, suitable for 8.7/10,8.7/15KV three cores PE and XLPE power cable.Cold shrinkable cable accessories made of Imported silicone rubberitis with very good electical performance,and also with ‘excellent hydrophobicity, high elasticity long usage life and constant pressure of shrinking The installation for cod shrinkable cable accessories i very convenient, no need special tools and fre, just need to pull out the plastic support strp.it can be used in a variety of harsh environment fr along time,so it can be widely used in electric power, petroleum, chemical industry, metallurgy allway, por and construction ands0 on. Before instalation construction personnel should rea this instruction carefull, and ‘make sure all the tools required are alin readiness, and construction personnel should be familiar with the use of various tools, inepection and precautions In the installation process of cable accessories the cable core part, the insulating material ‘ol for construction and the construction personel must keep clean.The construction site shouldbe with enough light ight enough clean and dry Outdoor construction should set up a protective shed. geri work should setup a operating platform Safety measures should be done when there ae ve equlpment nearby. ‘The installation temperatuce shouldbe above O°C,and the humidity should be lower ‘han 70%, which wil help to avoid take remedial measures when the insulation surface moisture condensation inthe low temperature and high humidity Remedial ‘measures shouldbe taken when the cable is water penetrated and damped ‘The method for cold shrinkable material installation: Make the spiral plastic support strip head outward exposed before setting into the old shrinkable tbe. Becasue the cold shrinkable tube will shrinking immediately after pulling ot the plastic support stip s0 the postion ofthe cold shrinkable tube must be confirmed before puling out the stip. ‘Special remarks: Inthe process of puling out the support strip, in order to avoid the spiral support ‘trip winding onthe covered objec, It shouldbe revolved around bya counter clockwise direction, and pullout while revolve around, so that itcan be ina straight lin in the tube to ensure smooth out. Inthe process of construction when remove the semi-conductve layer avoid to damage the core insulation itis strictly prohibited to damage the cable sheath and bend the cable overy + B.7/ISKY Cold shrinkable Thvee cores termination L.lug 2.Sealing tube 3.Terminal tube 4.Jacket tube 5.Breakout G.shield earth braid 7.Armor earth braid 8,Constant force spring 9.Stress cone 10.Copper shield layer 11.Semi-conductive layer 12.Insulation layer 13. Armor layer 14.Filing mastic 15,Self-adhesive tape Construction of cold shrinkable te for ISKV Three cores Power Cable Insulation tube Copper shield layer -LAccording to the requirement of cable termination installation position, firstly confirm the length L of the longest phase (For example Phase A) L=AsLi+6Omm. (The length of L1,L2,L3 is 450mm, maximum) 2.Cut the cable outer sheath layer according to the length of Land keep 30mm steel armor left then peel off the other steel armor ,also keep 15mm inner sheath layer and pick the cable filings. Then use VC tape to wrap around the wire core end temporary to prevent ‘the copper shield fall off. Use the abrasive paper or file to remove the painting in the surface of the steel arma. ——— wc, 7 copper Pv Insulation - oe SIN sda Soe : A aon te wy Filing mastic ‘Semi-conductve layer - p (repping tchomied) caper maeeerenS yt ee sed Breck “VY watersroot Ereoastime

You might also like