Overview
The Mist AP43 contains three IEEE 802.11ax radios that deliver 4x4 MIMO
with four spatial streams when operating in multi-user (MU) or single-user
(SU) mode.

1
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
I/O ports

2
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Reset Reset to the factory default settings

12VDC Support for the 12VDC power supply recommended by Mist

100/1000/2500BASE-T RJ45 interface that supports


Eth0+PoE-in
802.3at/802.3bt PoE PD

10/100/1000BASE-T RJ45 interface + 802.3af PSE (if PoE-


Eth1+PSE-out
in is 802.3bt)

USB USB2.0 support interface

8-pin interface for digital input, digital output, analog


IoT
input, and ground

3
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
AP43 Mounting

In a wall mount installation, please use screws that have a 1/4in. (6.3mm) diameter head with
a length at least 2 in. (50.8mm).

4
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
5
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
6
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
7
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
8
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
The bracket attaches to a rod that is 5/8”-11.

The bracket attaches to a rod that is M16-2.


9
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
10
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Technical Specifications:
Feature Description
802.3at/802.3bt PoE
Power options
12V/3A DC power supply
100-240VAC, 50-60 Hz, input
Powering adaptor
All regions (output): 12V/3A DC output
Dimensions 222mm x 222mm x 53mm (8.74in x 8.74in x 2.09in)
AP43: 1.39 kg (3.06 lbs)
Weight
AP43E: 1.46 kg (3.21 lbs)
Operating AP43: 0° to 40° C
temperature AP43E: -20° to 50° C
Operating humidity 10% to 90% maximum relative humidity, non-condensing

Operating altitude 3,048m (10,000 ft)


Electromagnetic
FCC Part 15 Class B
emissions
1 – 100/1000/2500BASE-T auto-sensing RJ-45 with PoE
1 – 10/100/1000BASE-T auto-sensing RJ-45
I/O USB2.0
IoT terminal block
12VDC
2.4GHz or 5GHz - 4x4:4SS 802.11ax MU-MIMO & SU-MIMO
5GHz - 4x4:4SS 802.11ax MU-MIMO & SU-MIMO
RF
2.4GHz / 5GHz scanning radio
2.4GHz BLE with Dynamic Antenna Array
Total maximum PHY rate – 4800 Mbps
Maximum PHY rate 5GHz – 2400 Mbps
2.4GHz or 5GHz – 1148 Mbps or 2400Mbps
Indicators Multi-color status LED

UL 62368-1
CAN/CSA-C22.2 No. 62368-1-14
UL 2043
Compliance standards FCC Part 15.247, 15.407, 15.107, and 15.109
RSS-247
ICES-003 (Canada)

Suitable for use in environmental air space in accordance with Section 300-22(C) of the
National Electrical Code, and Sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical
Code, Part 1, CSA C22.1.

11
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Warranty Information
The AP43 family of Access Points comes with a limited lifetime warranty.

Ordering Information:

Access Points
AP43-US Premium 802.11ax WiFi and BLE AP – Internal Antenna
for the US Regulatory domain

AP43E-US Premium 802.11ax WiFi and BLE AP – External Antenna


for the US Regulatory domain

AP43-WW Premium 802.11ax WiFi and BLE AP – Internal Antenna


for the WW Regulatory domain

AP43E-WW Premium 802.11ax WiFi and BLE AP – External Antenna


for the WW Regulatory domain

Mounting brackets
APBR-U Universal AP Bracket for T-Rail and Drywall mounting
for Indoor Access Points

APBR-T58 5/8-inch threaded rod bracket

APBR-M16 16mm threaded rod bracket

APBR-ADP-CR9 Adapter for channel rail and recessed 9/16” t-rail

APBR-ADP-RT15 Adapter for recessed 15/16" t-rail

APBR-ADP-WS15 Adapter for recessed 1.5" t-rail

12
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Power Supply options
DC-01 100-240VAC, 50-60 Hz, input
All regions (output): 12V/3A DC output

Regulatory Compliance Information:


This product and all interconnected equipment must be installed indoors within the
same building, including the associated LAN connections as defined by the 802.3at
Standard.

Operations in the 5.15GHz – 5.35GHz band are restricted to indoor usage only.

If you need further assistance with purchasing the power source, please contact Mist
Systems, Inc.

13
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
FCC Requirement for Operation in the United States of
America:
FCC Guideline for Human Exposure
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
49 cm between the radiator & your body.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.

FCC Caution
● Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
● This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
● For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range, it is
restricted to indoor environment.

14
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Industry Canada
This device complies with RSS-247 of the Industry Canada Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Ce dispositif est conforme à la norme CNR-247 d'Industrie Canada applicable aux
appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions
suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce
dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de
provoquer un fonctionnement indésirable.

Radiation Exposure Statement:


This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
55 cm between the radiator & your body.
Déclaration d'exposition aux radiations:Cet équipement est conforme aux limites
d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet
équipement doit être installé et utilisé avec un minimum de 55 cm de distance entre la
source de rayonnement et votre corps.

IC Caution
(i) The device for operation in the band 5150-5250 MHz is only for indoor use to reduce
the potential for harmful interference to co-channel mobile satellite systems;
(ii) The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and
5470-5725 MHz shall be such that the equipment still complies with the e.i.r.p. limit;
(iii) The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall
be such that the equipment still complies with the e.i.r.p. limits specified for point-to-
point and non-point-to-point operation as appropriate; and
(iv) Users should also be advised that high-power radars are allocated as primary users
(i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these
radars could cause interference and/or damage to LE-LAN devices.

Avertissement
Le guide d’utilisation des dispositifs pour réseaux locaux doit inclure des instructions
précises sur les restrictions susmentionnées, notamment :

(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement
pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable
aux systèmes de satellites mobiles utilisant les mêmes canaux;

15
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
(ii) le gain maximal d'antenne permis pour les dispositifs utilisant les bandes de 5250 à
5 350 MHz et de 5470 à 5725 MHz doit être conforme à la limite de la p.i.r.e;

(iii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5 725 à
5 850 MHz) doit être conforme à la limite de la p.i.r.e. spécifiée pour l'exploitation point
à point et l’exploitation non point à point, selon le cas;

(iv) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de
haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour
les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du
brouillage et/ou des dommages aux dispositifs LAN-EL.

CE

This device complies with the Radio Equipment Directive, 2014/53/EU, issued by the
Commission of the European Community.
Hereby, Mist Systems, Inc. declares that the radio equipment type (AP43) is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following:
https://www.mist.com/support/

The frequency and maximum EIRP Power in EU:

Bluetooth:
Frequency range (MHz) Maximum EIRP in EU (dBm)
2400 – 2483.5 9.55

WLAN:
Frequency range (MHz) Maximum EIRP in EU (dBm)
2400 – 2483.5 19.99
5150 – 5250 22.81
5250 – 5350 22.78
5500 – 5700 29.82

The minimum distance between the user or bystander and the radiating structure of the
transmitter is 20cm.

16
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Morocco

South Korea
해당 무선설비는 운용 중 전파혼신 가능성이 있음

Oman

Pakistan

TAC Number: 9.200/2020

17
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Belarus

Thailand
 เครืองโทรคมนาคมและอุปกรณ์นีมีความสอดคล ้องตามมาตรฐานหรือข ้อกําหนดทางเทคนิ คของ กสทช.

Russia
Подтверждение соответствия 1)Минкомсвязи России и 2) Евразийского Таможенного
Союза:

1. Декларация соответствия Евразийского Таможенного Союза № RU Д-


US.PA01/B.38167/2-0 от (30.04.2020) года, действительна до (29.04.2025) года,
зарегистрирована в реестре Евразийского Таможенного Союза (30.04.2020) года
2. Сертификат соответствия № OC-2-PД-1379 от (01.09.2020) года, действителен
до (01.09.2023) года, зарегистрирован в Федеральном агенстве связи (01.09.2020)
года
3. Декларация соответствия № Д-ИВPД – 6882 от (18.06.2020) года, действительна
до (18.06.2026) года, зарегистрирована в Федеральном агенстве связи
(26.06.2020) года
4. Декларация соответствия № Д-ИВPД – 6881 от (18.06.2020) года, действительна
до (18.06.2026) года, зарегистрирована в Федеральном агенстве связи
(26.06.2020) года

18
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved
Mexico
 La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es
posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este
equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda
causar su operación no deseada
 Este equipo ha sido diseñado para operar con las antenas que enseguida se
enlistan y para una ganancia máxima de antena de [8dBi por 2.4GHz y 10dBi por
5GHz]. El uso con este equipo de antenas no incluidas en esta lista o que tengan
una ganancia mayor que [8dBi por 2.4GHz y 10dBi por 5GHz] quedan prohibidas.
La impedancia requerida de la antena es de [50] ohms

19
AP43 Hardware Installation Guide
Mist Systems (C) Copyright 2020. All Rights Reserved