VFD R47
VFD R47
• Rated 110°C
Rockbestos Surprenant Type VFD Power Cables are high per- with an Aluminum/Polyester laminated tape to provide exception-
formance cables, designed for use in applications where high al shielding characteristics. The unarmored cables are dual listed
speed (IGBT Type) AC drives will be utilized. Type VFD cables as UL Type TC, and Marine Shipboard Cables.
are flexible, and employ an optimized Tinned Copper braid shield
Features
Performance Standards Construction
Optimized tinned copper braid with
Conductors:
Aluminum/Polyester laminated tape ITS and UL Listed as Marine Annealed, Flexible Tinned Copper,
shielding system provides 100% cover- Shipboard Class I per ASTM B33, B172, UL
age and an effective electrostatic • UL 1309 Type X110 1309 & CSA C22.2 No. 245
shield for isolation of the high • IEEE 45 & IEEE 1580 Shipboard Insulation:
frequency currents and potentials, • Un-Armored Also UL Type TC Proprietary, irradiation cross-linked
and an effective low impedance path Polyolefin (Exane®).
to ground for A.C. drive applications. Circuit Identification:
CSA Listed as Marine Ship Board Power Conductors: Dark Gray,
• CSA C22.2 No 245 Type X110 Red, Blue
High Dielectric Strength Insulation Ground Conductors: Green
• Withstands Voltage Spikes (2-3X) ITS Listed as Marine Shipboard – Ground Conductors:
IEC 60092-353 Three segmented, Green
Symmetrical Cable Construction Insulated grounding conductors with
• 3 Phase & 3 Ground Conductors the same voltage rating as the circuit
Meets Vertical Tray Flame Tests conductors.
• Cancellation of Magnetic Fields • IEEE 1202 Fillers:
• Lower Ground Conductor Current • IEC 600332-3 Category A Flame retardant, fibrillated
Flow Polypropylene as required.
• Reduction in Common Mode Noise Meets Cold Temperature Shield:
Requirements Overall, optimized Tinned Copper
Flexible Cable • UL and CSA -40°C Cold braid with Aluminum/Polyester lami-
• Class I Conductor and Braid Shield nated tape providing 100% coverage.
Impact Rated Jacket:
• -55° C Cold Bend Black, heavy duty, arctic grade
High Crush and Impact Resistance Neoprene. Colored Neoprene available
• Armored and Non-Armored Armored and Sheathed Cables on request
• Meets UL 2225 (Type MC) with no Suitable for Class I, Div. 1 & Zone 1 Armor (optional):
Armor Braided Bronze armor. Aluminum or
Tinned Copper braided armor available
Unarmored Cable Suitable for Class on request.
Proven 30 Year Exane® Reliability I, Div. 2 & Zone 2 Sheath (optional):
• Irradiation Cross-Linked Polyolefin Black, heavy duty, arctic grade
Insulation Neoprene. Colored Neoprene available
on request
Rockbestos-Surprenant Cable Corp. © 2001 • Clinton, MA • East Granby, CT • 800-444-3792 • 978-365-6331 • Fax: 978-365-4054 • http://www.r-scc.com R-47
Exane® VFD 2KV
Power Cable
• Three Conductor
• Rated 110°C
• ABS, UL, CSA, Lloyds
AWG Sq. mm No. X AWG Inch mm lb/1,000ft Kg/Km Inch mm lb/1,000ft Kg/Km
1/0 56.3 3 x10 1.450 36.8 1937 2882 1.665 42.3 2456 3655
2/0 66.5 3 x 10 1.547 339.3 2208 3285 1.822 46.3 2879 4285
3/0 92.1 3x8 1.698 43.1 2884 4292 1.973 50.1 3615 5379
4/0 112.6 3x8 1.824 46.3 3409 5073 2.099 53.3 4182 6223
262 133.1 3x6 2.022 51.4 4081 6074 2.297 58.4 4942 7355
313 158.7 3x6 2.169 55.1 4709 7008 2.444 62.1 5640 8393
373 189.4 3x6 2.277 57.8 5397 8031 2.552 64.8 6363 9470
444 225.2 3x6 2.440 62.0 6248 9299 2.715 69.0 7294 10855
535 271.2 3x6 2.654 67.4 7439 11070 2.989 75.9 8773 13056
646 327.5 3x6 2.962 75.2 8949 13317 3.297 83.7 10412 15496
Data for 600V and 2kv (Heavy Duty) available upon request.