0% found this document useful (0 votes)
57 views

Midea Msv1 XX SM

Uploaded by

u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views

Midea Msv1 XX SM

Uploaded by

u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 43

MSV1-07CR-QB8F MSV1-07HR-QB8F

MSV1-09CR-QB8F MSV1-09HR-QB8F
MSV1-12CR-QB8F MSV1-12HR-QB8F
MSV1-18CR-QB8F MSV1-18HR-QB8F
MSV1-07CR-NC2F MSV1-07HR-NC2F
MSV1-09CR-NC2F MSV1-09HR-NC2F
MSV1-12CR-NC2F MSV1-12HR-NC2F
MSV1-18CR-QB8F MSV1-18HR-QB8F
Content

Content

1 Precaution............................................................................................................................1
1.1 Safety Precaution ...................................................................................................................................... 1
1.2 Warning ..................................................................................................................................................... 1
2 Function ...............................................................................................................................4
3 Dimension............................................................................................................................5
4 Specification........................................................................................................................6
5 Refrigerant cycle diagram ................................................................................................10
6 Operation limits ................................................................................................................. 11
7 Wiring diagram ..................................................................................................................12
8 Installation details .............................................................................................................16
8.1 Wrench torque sheet for installation........................................................................................................ 16
8.2 Connecting the cables............................................................................................................................. 16
8.3 Pipe length and the elevation.................................................................................................................. 16
8.4 Air purging of the piping and indoor unit ................................................................................................. 17
8.5 Pumping down (Re-installation) .............................................................................................................. 18
8.6 Re-air purging (Re-installation) ............................................................................................................... 19
8.7 Balance refrigerant of the 2-way, 3-way valves ...................................................................................... 20
8.8 Evacuation............................................................................................................................................... 21
8.9 Gas charging ........................................................................................................................................... 22
9 Electronic function............................................................................................................23
9.1 Electronic control working environment .................................................................................................. 23
9.2 Proper symbols and their meaning ......................................................................................................... 23
9.3 Function................................................................................................................................................... 24
9.4 Protection ................................................................................................................................................ 24
9.5 Fan only mode......................................................................................................................................... 25
9.6 Cooling mode .......................................................................................................................................... 25
9.7 Dehumidifying mode................................................................................................................................ 26
9.8 Heating mode .......................................................................................................................................... 26
9.9 Defrosting mode(available for heating mode)......................................................................................... 27
9.10 Auto mode ............................................................................................................................................. 28
9.11 Force cooling function ........................................................................................................................... 28
9.12 Sleep mode ........................................................................................................................................... 28
9.13 Auto restart function .............................................................................................................................. 29
9.14 Ionizer (air clean) function..................................................................................................................... 29
9.15 Follow me function ................................................................................................................................ 30
9.16 Self-clean function................................................................................................................................. 30
9.17 Turbo ..................................................................................................................................................... 30
10 Model and Parameters ......................................................................................................32
11 Troubleshooting.................................................................................................................34
11.1 LCD Display board ................................................................................................................................ 34
11.2 Indoor Unit Error Display ....................................................................................................................... 35
11.3 Diagnostic chart ..................................................................................................................................... 36
-1-
Content
11.4 Resetting phenomenon often occurs during operation. ........................................................................ 37

11.5 Indoor Unit Error Display:E3. .............................................................................................................. 37

11.6 Indoor Unit Error Display:E5 or E6 ..................................................................................................... 38

11.7 Indoor Unit Error Display:E4 ............................................................................................................... 38

11.8 Indoor Unit Error Display:E1 ............................................................................................................... 38

11.9 Indoor Unit Error Display:E2 ............................................................................................................... 38

12 haracteristic of temperature sensor ................................................................................39

-2-
Service manual

1 Precaution

1.1 Safety Precaution

§ To prevent injury to the user or other people and property damage, the following instructions
must be followed.
§ Incorrect operation due to ignoring instruction will cause harm or damage.
§ Before service unit, be sure to read this service manual at first.

1.2 Warning

Ø Installation
§ Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated
circuit.
There is risk of fire or electric shock.
§ For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service
center.
Do not disassemble or repair the product, there is risk of fire or electric shock.
§ Always ground the product.
There is risk of fire or electric shock.
§ Install the panel and the cover of control box securely.
There is risk of fire of electric shock.
§ Always install a dedicated circuit and breaker.
Improper wiring or installation may cause fore or electric shock.
§ Use the correctly rated breaker of fuse.
There is risk of fire or electric shock.
§ Do not modify or extend the power cable.
There is risk of fire or electric shock.
§ Do not install, remove, or reinstall the unit by yourself (customer).
There is risk of fire, electric shock, explosion, or injury.
§ Be caution when unpacking and installing the product.
Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser and
evaporator.
§ For installation, always contact the dealer or an Authorized service center.
There is risk of fire, electric shock, explosion, or injury.
§ Do not install the product on a defective installation stand.
It may cause injury, accident, or damage to the product.
§ Be sure the installation area does not deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal
injury.
§ Do not let the air conditioner run for a long time when the humidity is very high and a door or
windows is left open.
Moisture may condense and wet or damage furniture.
§ Take care to ensure that power cable could not be pulled out or damaged during operation.
There is risk of fire or electric shock.

-1-
Service manual
§ Do not place anything on the power cable.
There is risk of fire or electric shock.
§ Do not plug or unplug the power supply plug during operation.
There is risk of fire or electric shock.
§ Do not touch (operation) the product with wet hands.
There is risk of fire or electric shock.
§ Do not place a heater or other appliance near the power cable.
There is risk of fire and electric shock.
§ Do not allow water to run into electric parts.
It may cause fire, failure of the product, or electric shock.
§ Do not store or use flammable gas or combustible near the product.
There is risk of fire or failure of product.
§ Do not use the product in a tightly closed space for a long time.
Oxygen deficiency could occur.
§ When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
product on.
Do not use the telephone or turn switches on or off.
There is risk of explosion or fire.
§ If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect
the power supply cable.
There is risk of electric shock or fire.
§ Stop operation and close the window in storm or hurricane. If possible, remove the product
from the window before the hurricane arrives.
There is risk of property damage, failure of product, or electric shock.
§ Do not open the inlet grill of the product during operation. (Do not touch the electrostatic
filter, if the unit is so equipped.
There is risk of physical injury, electric shock, or product failure.
§ When the product is soaked (flooded or submerged), contact an Authorized service center.
There is risk of fire or electric shock.
§ Be caution that water could not enter the product.
There is risk of fire, electric shock, or product damage.
§ Ventilate the product from time to time when operating it together with a stove, etc.
There is risk of fire or electric shock.
§ Turn the main power off when cleaning or maintaining the product.
There is risk of electric shock.
§ When the product is not be used for a long time, disconnect the power supply plug or turn off
the breaker.
There is risk of product damage or failure, or unintended operation.
§ Take care to ensure that nobody could step on or fall onto the outdoor unit.
This could result in personal injury and product damage.

Ø CAUTION
§ Always check for gas (refrigerant) leakage after installation or repair of product.
Low refrigerant levels may cause failure of product.
§ Install the drain hose to ensure that water is drained away properly.
A bad connection may cause water leakage.
§ Keep level even when installing the product.
To avoid vibration of water leakage.
§ Do not install the product where the noise or hot air from the outdoor unit could damage the
neighborhoods.
It may cause a problem for your neighbors.
-2-
Service manual
§ Use two or more people to lift and transport the product.
Avoid personal injury.
§ Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause
product malfunction or inefficient operation.

Ø Operational
§ Do not expose the skin directly to cool air for long periods of time. (Do not sit in the draft).
This could harm to your health.
§ Do not use the product for special purposes, such as preserving foods, works of art, etc. It is
a consumer air conditioner, not a precision refrigerant system.
There is risk of damage or loss of property.
§ Do not block the inlet or outlet of air flow.
It may cause product failure.
§ Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
§ Do not touch the metal parts of the product when removing the air filter. They are very sharp.
There is risk of personal injury.
§ Do not step on pr put anything on the product. (outdoor units)
There is risk of personal injury and failure of product.
§ Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
§ Do not insert hands or other object through air inlet or outlet while the product is operated.
There are sharp and moving parts that could cause personal injury.
§ Do not drink the water drained from the product.
It is not sanitary could cause serious health issues.
§ Use a firm stool or ladder when cleaning or maintaining the product.
Be careful and avoid personal injury.
§ Replace the all batteries in the remote control with new ones of the same type. Do not mix old
and mew batteries or different types of batteries.
There is risk of fire or explosion.
§ Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn of explode.
§ If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do
not use the remote of the batteries have leaked.
The chemical in batteries could cause burns or other health hazards.

-3-
Service manual

2 Function
20. Ionizer
Ø Indoor unit The function is operated by remote controller.
1. Operation ON/OFF by remote controller
21.Follow me.
2. Sensing by room temperature
Room temperature sensor. Pipe temperature The function is operated by remote controller.
sensor. 22. Self-clean
3. Room temperature control Function used after the Shut Down of cooling
Maintain the room temperature in accordance with operation to clean the Evaporator and keep it as fresh
the setting temperature. for the next operation. The function is operated by
4. Starting temperature control remote controller..
Indoor fan is delayed for 5 sec at the starting.
23.Turbo
5. Time Delay Safety control
Restarting is for approx. 3 minutes. This function enables the unit to reach the preset
6. Indoor fan speed control temperature in the shortest time under cooling mode
High, med, low.
7. Operation indication LCD
Ø Outdoor unit
Light up in the LCD for each operation mode. 1. Power relay control
8. Two-direction air vane The unit has 3 mins delay between continuously
The unit will decide the louver direction according ON/OFF operations.
to operation mode. 2. Low noise air flow system
9. Sleep mode auto control Bird tail propeller fan makes the outdoor unit run
The fan is turn to low speed (cooling/heating). more quietly
The unit will be turn off after seven hours. 3. Hydrophilic aluminum fin
10. Independent dehumidification The hydrophilic fin can improve the heating
The function is usually used in rainy days in efficiency at operation mode.
springtime or damp areas 4. 4 way valve control
11. Self-diag. function It is only operated in the heating operation mode
The function will be operate in any operation mode. except defrosting operation.
12. Air flow Direction control 5. Anti-rust cabinet
The louver can be set at the desired position or Made from electrolytic zinc steel sheet and anti-rust
swing up and down automatically coated components.
13. Auto mode 6. Valve protection cover
The unit can be change by the room temperature. It protects the valves and prevents water from
14. Anti-cold function dripping.
Prevent the cold wind at the beginning of unit start. 7. Discharge pipe temperature
15. Temp. Compensation
16. Defrost mode
17. Auto-restart function
18. Flexible wiring connection
19. Self-Clean

-4-
Service manual

3 Dimension
Indoor unit

Di mensi on
W H D
Mode
7K 795 270 165
9K 795 270 165
12K 845 286 165
18K 995 292 194

outdoor unit

Dimension
W H D L1 L2
Mode
7K 700 535 285 458 250
9K(50Hz) 700 535 285 458 250
9K(60Hz) 780 540 250 549 266
12K 780 540 250 549 266
18K 845 695 335 560 360
-5-
Service manual

4 Specification
Model MSV1-07CR-QB8F MSV1-07HR-QB8F MSV1-07CR-NC2F MSV1-07HR-NC2F
Power supply Ph-V-Hz 1, 220-240V~, 50Hz 1, 220-240V~, 50Hz 1, 220-230V~, 60Hz 1, 220-230V~, 60Hz
Capacity Btu/h 7000 7000 7000 7000
Input W 730 730 660 660
Cooling
Rated current A 3.3 3.3 3 3
EER Btu/w.h 9.55 9.55 10.9 10.9
Capacity Btu/h —— 8000 —— 8000
Input W —— 780 —— 730
Heating
Rated current A —— 3.5 —— 3.3
COP W/W —— 10.2 —— 10.9
Max. current A 5 5 5 5
Starting current A 14 14 21 21
Model 2P14C225ANA 2P14C225ANA 2R12S3R236A6B 2R12S3R236A6B
Type ROTARY ROTARY ROTARY ROTARY
Brand Matsushita Matsushita Matsushita Matsushita
Capacity Btu/h 7455 7455 7933 7933
Input W 725 725 737 737
Compressor
Rated current(RLA) A 3.4 3.4 3.3 3.3
Locked rotor Amp(LRA) A 14 14 21 21
Thermal protector External External External External
Capacitor uF 25 25 15 15
Refrigerant oil ml 270 270 550 550
Model RPG20D RPG20D RPG13B RPG13B
Brand Welling Welling Welling Welling
Indoor
Input W 32 32 32 32
fan motor
Capacitor uF 1.2 1.2 1.2 1.2
Speed(hi/mi/lo) r/min 1040/900/800 1040/900/800 1040/900/800 1040/900/800
Indoor air flow (Hi/Mi/Lo) m3/h 450 450 450 450
Indoor noise level (Hi/Mi/Lo) dB(A) 36/33/30 36/33/30 36/33/30 36/33/30
Model YDK24-6T YDK24-6T YDK20-6B YDK20-6B
Brand Welling Welling Welling Welling
Outdoor
Input W 56 56 58 58
fan motor
Capacitor uF 2.5 2.5 2.5 2.5
Speed r/min 800 800 750 750
Outdoor air flow m3/h 1500 1500 1500 1500
Outdoor noise level dB(A) 50 50 54 54
Refrigerant type R22 g 530 570 730 730
Design pressure MPa 2.6 2.6 2.6 2.6
Liquid side/ Gas side mm Ф 6.35/Ф 9.53 Ф 6.35/Ф 9.53 Ф 6.35/Ф 9.53 Ф 6.35/Ф 9.53
Refrigerant
Max. refrigerant pipe length m 10 10 10 10
piping
Max. difference in level m 5 5 5 5
Operation temp ℃ 17-30 17-30 17-30 17-30
Ambient temp ℃ 18-45 -7-45 18-45 -7-45
Application area m2 10-14 10-14 10-14 10-14
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are
normally somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product
improvement.

-6-
Service manual
Model MSV-09CR-QB8F MSV-09HR-QB8F MSV-09CR-NC2F MSV-09HR-NC2F
Power supply Ph-V-Hz 1, 220-240V~, 50Hz 1, 220-240V~, 50Hz 1, 220-230V~, 60Hz 1, 220-230V~, 60Hz
Capacity Btu/h 9000 9000 9000 9000
Input W 940 940 820 820
Cooling
Rated current A 4.2 4.2 3.7 3.7
EER Btu/w.h 9.55 9.55 10.9 10.9
Capacity Btu/h ___________ 10000 ___________ 10000
Input W ___________ 980 ___________ 910
Heating
Rated current A ___________ 4.4 ___________ 4.1
COP W/W ___________ 10.2 ___________ 10.9
Max. current A 6.3 6.3 6 6
Starting current A 19.8 19.8 26 26
Model 2P18S225ANK 2P18S225ANK 2P14S236A1E 2P14S236A1J
Type Rotary Rotary Rotary Rotary
Brand Matsushita Matsushita Matsushita Matsushita
Capacity Btu/h 9912 9912 9161 9195
Input W 970 970 845 850
Compressor
Rated current(RLA) A 4.5 4.5 3.8 3.8
Locked rotor Amp(LRA) A 19.8 19.8 26 26
Thermal protector External External External External
Capacitor uF 30 30 30 30
Refrigerant oil ml 350 350 270 350
Model RPG20D RPG20D RPG13B RPG13B
Brand Welling Welling Welling Welling
Indoor
Input W 32 32 32 32
fan motor
Capacitor uF 1.2 1.2 1.2 1.2
Speed(hi/mi/lo) r/min 1040/900/800 1040/900/800 1040/900/800 1040/900/800
Indoor air flow (Hi/Mi/Lo) m3/h 550 550 550 550
Indoor noise level (Hi/Mi/Lo) dB(A) 38/35/32 38/35/32 38/35/32 38/35/32
Model YDK24-6T YDK24-6T YDK25-6B YDK24-6FB
Brand Welling Welling Welling Welling
Outdoor
Input W 70 70 82.5 72
fan motor
Capacitor uF 3 3 2.5 2.5
Speed r/min 850 850 950 830
Outdoor air flow m3/h 1800 1800 1800 1800
Outdoor noise level dB(A) 52 52 54 54
Refrigerant type R22 g 580 800 900 1000
Design pressure MPa 2.6 2.6 2.6 2.6
Liquid side/ Gas side mm Ф 6.35/Ф 9.53 Ф 6.35/Ф 9.53 Ф 6.35/Ф 9.53 Ф 6.35/Ф 9.53
Refrigerant
Max. refrigerant pipe length m 10 10 10 10
piping
Max. difference in level m 5 5 5 5
Operation temp ℃ 17-30 17-30 17-30 17-30
Ambient temp ℃ 18-45 -7-45 18-45 -7-45
Application area m2 14-21 14-21 14-21 14-21
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are
normally somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product
improvement.

-7-
Service manual

Model MSV1-12CR-QB8F MSV1-12HR-QB8F MSV1-12CR-NC2F MSV1-12HR-NC2F


Power supply Ph-V-Hz 1, 220-240V~, 50Hz 1, 220-240V~, 50Hz 1, 220-230V~, 60Hz 1, 220-230V~, 60Hz
Capacity Btu/h 12000 12000 12000 12000
Input W 1260 1260 1100 1100
Cooling
Rated current A 5.6 5.6 4.9 4.9
EER Btu/w.h 9.55 9.55 10.9 10.9
Capacity Btu/h ___________ 13000 ___________ 13000
Input W ___________ 1270 ___________ 1190
Heating
Rated current A ___________ 5.7 ___________ 5.3
COP W/W ___________ 10.2 ___________ 10.9
Max. current A 1.4 1.4 1.4 1.4
Starting current A 1700 1700 1500 1500
Model PH225X2C-4FT PH225X2C-4FT 2P19S236A1J 2P19S236A1J
Type Rotary Rotary Rotary Rotary
Brand GMCC GMCC Matsushita Matsushita
Capacity Btu/h 13197/13299 13197/13299 12659 12659
Input W 1250/1285 1250/1285 1165 1165
Compressor
Rated current(RLA) A 5.7/5.5 5.7/5.5 5.2 5.2
Locked rotor Amp(LRA) A 29.9/33 29.9/33 33 33
Thermal protector UP3RE0591-T56 UP3RE0591-T56 External External
Capacitor uF 35 35 30 30
Refrigerant oil ml 480 480 350 350
Model RPG20D RPG20D RPG13B RPG13B
Brand Welling Welling Welling Welling
Indoor
Input W 32 32 32 32
fan motor
Capacitor uF 1.5 1.5 1.2 1.2
Speed(hi/mi/lo) r/min 1260/1080/900 1260/1080/900 1260/1080/900 1260/1080/900
Indoor air flow (Hi/Mi/Lo) m3/h 650 650 650 650
Indoor noise level (Hi/Mi/Lo) dB(A) 42/39/36 42/39/36 42/39/36 42/39/36
Model YDK24-6 YDK24-6 YDK25-6B YDK25-6B
Brand Welling Welling Welling Welling
Outdoor
Input W 70 70 82.5 82.5
fan motor
Capacitor uF 2.5 2.5 2.5 2.5
Speed r/min 850 850 950 950
Outdoor air flow 3
m /h 1800 1800 1800 1800
Outdoor noise level dB(A) 54 54 55 55
Refrigerant type R22 g 850 900 1020 1050
Design pressure MPa 2.6 2.6 2.6 2.6
Liquid side/ Gas side mm Ф6.35/φ12.7 Ф6.35/φ12.7 Ф6.35/φ12.7 Ф6.35/φ12.7
Refrigerant
Max. refrigerant pipe length m 10 10 10 10
piping
Max. difference in level m 5 5 5 5
Operation temp ℃ 17-30 17-30 17-30 17-30
Ambient temp ℃ 18-45 -7-45 18-45 -7-45
Application area 2
m 18-26 18-26 18-26 18-26
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are
normally somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product
improvement.

-8-
Service manual

Model MSV1-18CR-QB8F MSV1-18HR-QB8F


Power supply Ph-V-Hz 1, 220-240V~, 50Hz 1, 220-240V~, 50Hz
Capacity Btu/h 17000 17000
Input W 1650 1650
Cooling
Rated current A 7.5 7.5
EER Btu/w.h 9.55 9.55
Capacity Btu/h ___________ 19000
Input W ___________ 1800
Heating
Rated current A ___________ 8.2
COP Btu/w.h ___________ 10.24
Max. current A 11 11
Starting current A 34 34
Model PH310X2CS-4KU3 PH310X2CS-4KU3
Type Rotary Rotary
Brand GD Toshiba GD Toshiba
Capacity Btu/h 18254 18254
Input W 1690 1690
Compressor
Rated current(RLA) A 7.85 7.85
Locked rotor Amp(LRA) A 34 34
Thermal protector Internal Internal
Capacitor uF 35UF/370V 35UF/370V
Refrigerant oil ml 750 750
Model RPG28D RPG28D
Brand Welling Welling
Indoor
Input W 55 55
fan motor
Capacitor uF 1.5 1.5
Speed(hi/mi/lo) r/min 1280/1250/1100/1000 1280/1250/1100/1000
Indoor air flow (Hi/Mi/Lo) m3/h 800/700/600 800/700/600
Indoor noise level (Hi/Mi/Lo) dB(A) 42 42
Model YDK53-6C YDK53-6C
Brand Welling Welling
Outdoor
Input W 125 125
fan motor
Capacitor uF 3 3
Speed r/min 800 800
Outdoor air flow m3/h 1900 1900
Outdoor noise level dB(A) 54 54
Refrigerant type R22 g R22/1870 R22/1870
Design pressure MPa 2.6 2.6
Liquid side/ Gas side mm Ф6.35/φ12.7 Ф6.35/φ12.7
Refrigerant
Max. refrigerant pipe length m 10 10
piping
Max. difference in level m 5 5
Operation temp ℃ 17-30 17-30
Ambient temp ℃ 18-45 -7-45

Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are
normally somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product
improvement.

-9-
Service manual

5 Refrigerant cycle diagram

Ø Cooling only

Ø Heat pump mode

- 10 -
Service manual

6 Operation limits
Cooling operation

Outdoor unit air temp.℃ DB

Indoor air temp. ℃ DB

Note: The chart is the result from the continuous operation under constant air temperature
conditions. However, excludes the initial pull-down stage.

Heating operation

Indoor air temp. ℃ DB

Outdoor unit air temp.℃ DB

Note: The chart is the result from the continuous operation under constant air temperature
- 11 -
Service manual
conditions. However, excludes the initial pull-down stage.

7 Wiring diagram

MSV1-07CR-QB8F MSV1-09CR-QB8F MSV1-12CR-QB8F

MSV1-07CR-NC2F MSV1-09CR-NC2F MSV1-12CR-NC2F

MSV1-18CR-QB8F
Indoor unit:

( I NDOOR UNI T)
Y/ G ANI ON GENERATOR SWI TCH BOARD SWI NG MOTOR M1 CONTROL TOP AI R
POWER SUPPLY I NDOOR MOTOR
M 5 5 I N LET LOUVER
BROWN( OR BLACK) M2
BLUE( OR WHI TE) M 3 5
Y/ G( OR GREEN)
1 2 1 3 5 3 2 1 3 2 1 123 4 5 1 2 34 5
1 2 1 3 5 3 2 1 3 2 1 12 3 45 1 2 34 5
CN14 CN8 CN12 CN4 CN3
7 6 5 4 3 21

CN7
DI SPLAY
P3 CN11 BOARD
CURRENT I NDUCTOR
MAI N BOARD
CN2
21
21

COMPRESSOR RELAY
AMBI ENT SENSOR
CN9 CN15 CN1
21
21

1234 1 2
12 3 4 1 2 EVAPORATOR SENSOR
RED BLACK
Y/ G

1 2( N) 3 4 5- WAY TERMI NAL


INDOOR UNI T TRANSFORMER
TO OUTDOOR UNIT

MSV1-07CR-QB8F MSV1-09CR-QB8F MSV1-12CR-QB8F

MSV1-07CR-NC2F MSV1-09CR-NC2F MSV1-12CR-NC2F


outdoor unit:

- 12 -
Service manual

1 2( N)
YELLOW/ GREEN

BLACK

OVERLOAD
RELAY
( I NTERNAL/ RED BLACK RED
EXTERNAL
DEPENDI NG BLACK
ON MODELS) C RED FAN RED
COMPRESSON M R
M BLUE
~ BLUE
S
COMPRESSON ~ FAN CAPACI TON
CAPACI TON
YELL OW/GREEN

MSV1-18CR-QB8F
outdoor unit:

- 13 -
Service manual

MSV1-07HR-QB8F MSV1-09HR-QB8F MSV1-12HR-QB8F

MSV1-07HR-NC2F MSV1-09HR-NC2F MSV1-12HR-NC2F

MSV1-18HR-QB8F
Indoor unit:

( I NDOOR U
NI T)
Y/ G ANI ON GENERATOR SWI TCH BOARD SWING MOTOR M1 CONTROL TOP AI R
POWER SUPPLY INDOOR MOTOR
M 5 5 I N LET LOUVER
BROWN( OR BLACK) M 3 5
M2
BLUE(OR WHI TE)
Y/ G( OR GREEN)
1 2 1 3 5 3 2 1 3 2 1 1 2 34 5 12 345
1 2 1 3 5 3 2 1 3 2 1 1 23 4 5 12 345
CN7 CN14 CN8 CN12 CN4

7 6 5 4 3 21
CN3 DI SPLAY
P3 CN11 BOARD
CURRENT I NDUCTOR
MAI N BOARD
CN2

21
21
P5
COMPRESSOR RELAY
AMBI ENT SENSOR
P4 CN9 CN15 CN1

21
21
YELLOW 12 34 1 2
12 3 4 1 2 EVAPORATOR SENSOR
RED BLACK BLUE
Y/ G

1 2( N) 3 4 5-WAY TERMI NAL


I NDOOR UNI T TRANSFORMER
TO OUTDOOR UNI T

MSV1-07HR-QB8F MSV1-09HR-QB8F MSV1-12HR-QB8F

MSV1-07HR-NC2F MSV1-09HR-NC2F MSV1-12HR-NC2F


outdoor unit:

- 14 -
Service manual

I NDOOR UNI T
OUTDOOR UNI T

1 2(N) 3 4
BL UE
Y&G

4- WAY
OVERLOAD BL ACK
RELAY BL UE
BL ACK
C BL ACK RED
COMPRESSOR
R( M) RED
RE D RED
FAN
S MOTOR
Y&G BL UE BL UE
COMPRESSOR
CAPACI TOR FAN CAPACI TOR

MSV1-18HR-QB8F
outdoor unit:

- 15 -
Service manual

8 Installation details

8.1 Wrench torque sheet for installation

Outside diameter Torque


mm inch Kg.m
φ6.35 1/4 1.8
φ9.52 3/8 4.2
φ12.7 1/2 5.5
φ15.88 5/8 6.6
φ19.05 3/4 6.6

8.2 Connecting the cables

The power cord of connect should be selected according to the following specifications sheet.
Grade
Amp 10 15 20
mm2 1.0 1.5 2.5

8.3 Pipe length and the elevation

Standard
Max. Max. Additional
length
Capacity Pipe size
(m) Elevation Elevation refrigerant
Btu/h GAS LIQUID B (m) A (m) (g/m)
3/8’’ (φ9.52) 1/4’’ (φ6.35) 5 5 10 30
7k~12K
1/2’’ (φ12.7) 1/4’’ (φ6.35) 5 5 10 30
1/2’’ (φ12.7) 1/4’’ (φ6.35) 5 8 15 30
16K~28K 5/8’’ (φ15.88) 1/4’’ (φ6.35) 5 10 20 30
5/8’’ (φ15.88) 3/8’’ (φ9.52) 5 10 20 65
5/8’’ (φ15.88) 3/8’’ (φ9.52) 5 15 30 65
30K~36K
3/4’’ (φ19.05) 3/8’’ (φ9.52) 5 15 30 65

In case that more


than 5m.

Caution:
Capacity is base on standard length and maximum allowance length is base of reliability.
Oil trap should be install per 5-7 meters.
- 16 -
Service manual

8.4 Air purging of the piping and indoor unit

Required tools:
Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak
detector.
Note:
The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration
piping, it will affect the compressor, reduce the cooling capacity, and could lead to a malfunction
of unit.
Be sure, using a torque wrench to tighten the service port cap (after using the service port), so
that it prevents the gas leakage from the refrigeration cycle.

Procedure:

1. Recheck the piping connections.


2. Open the valve stem of the 2-way valve counterclockwise approximately 90’, wait 10 seconds, and
then set it to closed position.
Be sure to use a hexagonal wrench to operate the valve stem
3. Check for gas leakage.
Check the flare connection for gas leakage
4. Purge the air from the system.
5. Set the 2-way valve to the open position and remove the cap from the 3-way valve’s service port.
6. Using the hexagonal wrench to press the valve core pin, discharge for three seconds and then wait
for one minute.
7. Use torque wrench to tighten the service port cap to a torque of 1.8 kg.m. (18n.m)
8. Set the 3-way valve to the opened position.
9. Mounted the valve stem nuts to the 2-way and 3-way valves.
10. Check for gas leakage.
11. At this time, especially check for gas leakage from the 2-way and 3-way stem nuts, and from the
- 17 -
Service manual
service port.
Caution:
If gas leakage is discovered in step (3) above, take the following measures.
If the leaks stop when the piping connections are tightened further, continue working from step
(4).
If the gas leaks do not stop when the connections are retightened, repair the location of the
leak, discharge all of the gas through the service port, and then recharge with the specified
amount of gas from a gas cylinder.

8.5 Pumping down (Re-installation)

Procedure:
1. Confirm that both the 2-way and 3-way valves are set to the opened position.
Remove the valve stem caps and confirm that the valve stems are in the opened position.
Be sure to use a hexagonal wrench to operate the valve stems.
2. Operate the unit for 10 to 15 minutes.
3. Stop operation and wait for 3 minutes, then connect the charge set to the service port of the 3-way
valve.
Connect the charge hose with the push pin to the gas service port.
4. Air purging of the charge hose.
Open the low-pressure valve on the charge set slightly to purge air from the charge hose.
5. Set the 2-way valve to the close position.
6. Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 0.1MPa.
7. Immediately set the 3-way valve to the closed position.
- 18 -
Service manual
Do this quickly so that the gauge ends up indicating 0.3 to 0.5Mpa.
8. Disconnect the charge set, and amount the 2-way and 3-way valve’s stem nuts and service port
caps.
Use a torque wrench to tighten the service port cap to a torque of 1.8 kg.m.
Be sure to check for gas leakage.

8.6 Re-air purging (Re-installation)

Procedure:
1. Confirm that both the 2-way and 3-way valves are set to the closed position.
2. Connect the charge set and a charging cylinder to the service port of the 3-way valve.
3. Leave the valve on the charging cylinder closed.
4. Air purging.
5. Open the valves on the charging cylinder and the charge set. Purge the air by loosening the flare
nut on the 2-way valve approximately 45’ for 3 seconds then closing it for 1 minutes; repeat 3 times.
6. After purging the air, use a torque wrench to tighten the flare nut to on the 2-way valve.
7. Check the gas leakage.
8. Check the flare connections for gas leakage.
9. Discharge the refrigerant.
10. Close the valve on the charging cylinder and discharge the refrigerant until the gauge indicate 0.3
to 0.5 Mpa.
11. Disconnect the charge set and the charging cylinder, and set the 2-way and 3-way valves to the
open position.
12. Be sure to use a hexagonal wrench to operate the valve stems.
13. Mount the valve stems nuts and the service port cap.
Be sure to use a torque wrench to tighten the service port cap to a torque 18N.m.
Be sure to check the gas leakage.
- 19 -
Service manual

8.7 Balance refrigerant of the 2-way, 3-way valves

Procedure:
1. Confirm that both the 2-way and 3-way valves are set to the open position.
2. Connect the charge set to the 3-way valve’s service port.
Leave the valve on the charge set closed.
Connect the charge hose with the push pin to the service port.
3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge indicates
0.05 to 0.1 Mpa.
If there is no air in the refrigeration cycle [the pressure when the air conditioner is not running is higher than
0.1Mpa, discharge the refrigerant until the gauge indicates 0.05 to 0.1 Mpa. If this is the case, it will not be
necessary to apply a evacuation.
Discharge the refrigeration gradually; if it is discharged too suddenly, the refrigeration oil sill be discharged.

- 20 -
Service manual

8.8 Evacuation

Procedure:
1. Connect the vacuum pump to the charge set’s centre hose.
2. Evacuation for approximately one hour.
Confirm that the gauge needle has moved toward -0.1 Mpa (-76 cmHg) [vacuum of 4 mmHg or less].
3. Close the valve (Low side) on the charge set, turn off the vacuum pump, and confirm that the gauge
needle does not move (approximately 5 minutes after turning off the vacuum pump).
4. Disconnect the charge hose from the vacuum pump.
Vacuum pump oil, if the vacuum pump oil becomes dirty or depleted, replenish as needle.

- 21 -
Service manual

8.9 Gas charging

Procedure:
1. Connect the charge hose to the charging cylinder.
Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the
cylinder.
2. Purge the air from the charge hose.
Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air (be
careful of the liquid refrigerant).
3. Open the valves (Low side) on the charge set and charge the system with liquid refrigerant.
If the system cannot be charge with the specified amount of refrigerant, if can be charged with a little at a time
(approximately 150g each time0 while operating the air conditioner in the cooling cycle; however, one time is not
sufficient, wait approximately 1 minute and then repeat the procedure.(pumping down-pin).
4. Immediately disconnect the charge hose from the 3-way valve’s service port.
Stopping partway will allow the refrigerant to be discharged.
If the system has been charged with liquid refrigerant while operating the air conditioner, turn off the air
conditioner before disconnecting the hose.
5. Mounted the valve stem caps and the service port
Use torque wrench to tighten the service port cap to a torque of 18N.m.
Be sure to check for gas leakage.

- 22 -
Service manual

9 Electronic function

9.1 Electronic control working environment

Input voltage: 198~253V


Input power frequency: 50/60Hz
Ambient temperature: -7°C+43°C
Indoor fan normal working amp is less than 1A
Outdoor fan normal working amp is less than 1.5A
Four-way valve normal working amp is less than 1A
Swing motor: DC12V
Compressor: single-phase power supply. Its normal working amp is less than 15A

9.2 Proper symbols and their meaning

TA: Indoor ambient temperature


TE: Indoor evaporator temperature
TS: Setting temperature through the remote controller
I3sec: Self-protection amp of compressor, continue three seconds until turns off the compressor.
I5MIN: Self-protection amp of compressor, continue five minutes until turns off the compressor.
IFAN: Self-protection amp of outdoor fan/indoor fans when they change from higher wind to lower wind.
IRESTORE: Amp self-protection return value
THDEFROST: High wind, defrosting temperature difference
TMDEFROST: Middle wind, defrosting temperature difference
TLDEFROST: Low wind, defrosting temperature difference
TE1: Anti-cold wind, from Fan Off to Breeze temperature
TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature
TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature
TE4: Anti-cold wind, from Breeze to Fan Off temperature
TE5: Evaporator low temperature protection entering temperature
TE6: Evaporator low temperature protection restoring temperature
TE7: Evaporator high temperature protection, compressor off temperature
TE8: Evaporator high temperature protection, fan off temperature
TE9: Evaporator high temperature protection, restoring temperature

- 23 -
Service manual

9.3 Function

Remote receiving
Testing and forced running
Position set for indoor unit wind vane
LCD displaying and alarm
Timer On or off
Protection for the compressor
Current protection
High temperature protection of indoor heat exchanger at heating mode
Auto defrosting and heating recovery at heating mode
Anti cold air at heating mode
Anti frozen at cooling mode
Auto restart
Self-Clean
Ionizer
Follow me
Auto clean

9.4 Protection

9.4.1 3 minutes delay at restart for compressor.


9.4.2 Sensor protection at open circuit and breaking disconnection
9.4.3 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High
Fan+300RPM)or too low(lower than 400RPM), the unit stops and LED displays failure information and
can’t returns to normal operation automatically.
9.4.4 Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops and
LED displays failure information and can’t returns to normal operation automatically.
9.4.5 The current protection of the compressor

If compressor turns off for continuously 4 times due to current protection in 5 minutes from Compressor
On, the unit stops and LCD displays failure information and can’t returns to normal operation
automatically.
- 24 -
Service manual

9.5 Fan only mode

Fan speed is high/mid/low/ Auto

9.6 Cooling mode

The 4-way valve is closed at cooling mode.


The action of the compressor and the outdoor fan:(T=indoor temperature)

Auto fan at cooling mode:

Anti-freezing control to indoor evaporator at cooling mode ( T: evaporator temp. )

Condenser high temperature protection (only for heat pump)

- 25 -
Service manual

9.7 Dehumidifying mode

Indoor fan speed at low speed.


Protection is same as cooling mode.

9.8 Heating mode

9.8.1 Generally, the 4-way valve is open in heating mode, but it is closed in defrosting mode. 4-way valve
must delay 2 minutes compared with compressor if the compressor changed into non-heating mode or
turned off. 4-way valve doesn't delay in dehumidifying mode.
9.8.2 Generally, the outdoor fan is turned off with the on-off action of compressor in heating mode, except
for the defrosting mode or the end of defrost.
9.8.3 Action of compressor and outdoor fan motor at heating mode: compressor must run for 7 minutes
after starting and then judge temperature. Meanwhile other protections are still valid.

* This parameter can be changed from 0 to 3

9.8.4 Indoor Fan actions at heating mode


Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold wind
function prevails.
Anti-cold wind control function at heating mode (T=indoor exchanger temp.)

9.8.5 Auto wind at heating mode (T=indoor temp.)

Med fan

Room temp. down Room temp. up

High fan

0 2 T-Ts

- 26 -
Service manual
9.8.6 Indoor evaporator high-temperature protection at heating mode
(T=indoor exchanger temp.)

The louver opens to Standard Angle ANGLHEAT when power is on for the first time

9.9 Defrosting mode(available for heating mode)

9.9.1 Defrosting condition:


Defrost starts when either of the following:
T3 lower than 0’C, lasts for more than 40 minutes, provided that the time period then the temperature
is lower than -3’C consecutively reaches 3 minutes.
Calculate from the end of latest defrost, evaporator high temp. protection only closes outdoor fan
with the compressor still running. Add up to 90 minutes.
9.9.2 Conditions of defrost ending:
Defrosting ends when either of the following:
The time gets to 10 minutes.
T3>20’C.
The circulation is as following:
9.9.3 Defrosting Actions

Defrost 10 or 6 minutes

Compressor 25s

5s
4-way valve

2s

Outdoor fan

Indoor fan

10s

Remark: when the evaporator pipe temperature sensor more than TE16, the indoor fan start to run.

- 27 -
Service manual

9.10 Auto mode

9.10.1 The air conditioner automatically selects one of the following operation modes: cooling, heating or
fan only according to the temperature difference between room temperature (TA) and set temperature
(TS).

9.10.2 The indoor fan blows automatically in corresponding selected mode;

9.10.3 The motion of indoor fan’s blade should accord with the selected operation mode;

9.10.4 One mode should be carried out for at least 15 minutes once selected. If the compressor cannot
start for 15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect
when the set temp. varies

9.11 Force cooling function

9.11.1 Select forced cooling function with the forced cooling button or the switch
9.11.2 The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan mode

is set as low, the A/C operates at the DRY mode with a set temp. of 24℃

9.11.3 All protections of remote control cooling are available at forced cooling operation
9.11.4 Forced Auto function
Select forced auto function with the forced auto button or the switch.

In forced auto status the A/C operates at remote control mode with a set temp. of 24℃.

Manual operation is controlled by touching buttons and divided into force cooling and forced auto
mode.
It transfer between these two modes by pressing the buttons, the cycling order of the button press is as
below graph show to you.

9.12 Sleep mode

9.12.1 The sleep function is available at cooling, heating or auto mode


9.12.2 Cooling:

- 28 -
Service manual
The set temperature rise 1℃ per hour. Two hours later, the set temperature will maintain as a
constant and the fan speed is kept at low speed.

9.12.3 Heating:
The set temperature decrease 1℃ per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).

9.12.4 Auto:
After an hour running under economic mode, the set temp will rise 1℃, if it is under cooling mode; the
set temp will decrease 1℃,if it is under heating mode; the set temp will be changeless, if it is under
fan-only mode; the condition will be the same after the air conditioner running under economic mode
after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7
hours the unit stops.

9.13 Auto restart function

In case of a sudden power failure, this function automatically sets the unit to previous settings before
the power failure when power returns.

9.14 Ionizer (air clean) function

9.14.1 Ionizer (air clean) function is effected when the unit is working and controlled by the remote
controller.
9.14.2 This function is active when the unit received the signal from the remote controller first time and
inactive when received the signal again. Repeat this circle when received signal again.
9.14.3 This function is working only when the indoor fan is working.
9.14.3 This function will not stop when the working mode changed, and be inactive when the unit shut
- 29 -
Service manual
down.

9.15 Follow me function

9.15.1 This function starts when the indoor unit received the signal from remote controller, and the air
conditioner is operated by the temperature information included in the signal and the set temperature.
In this mode, the indoor temperature sensor in the indoor unit is inactive.
9.15.2 When the indoor unit received the signal by pressing the button of remote controller, the buzzer
in indoor unit will sound once. And the remote controller will send the corrected signal automatic per 3
minutes, the buzzer keep quiet at this time.
9.15.3 When the indoor unit have not received the corrected signal for 7 minutes, this function will be
shut down. The air conditioner is working in common way.

9.16 Self-clean function

9.16.1 This function is available only under COOLING (including AUTO and FORCE cooling mode) or
DRY mode, no matter it’s cooling only or cooling & heating model.
9.16.2 For cooling only models, the air conditioner will operate under FAN ONLY mode at LOW fan
speed for 30 minutes, and then stop the operation and the unit turn off.
9.16.3 For cooling & heating models, the air conditioner will operate: FAN ONLY mode at Low fan
speed(13 minutes)--Heating operation with LOW fan speed (1 minute)---FAN ONLY operation(2
minutes)--Stop Operation---Turn off the unit.
9.16.4 Once the Auto Clean function is activated, all TIMER setting will be cancelled.
9.16.5 This operation will be stopped only by press the AUTO CLEAN button on remote controller again
or the OFF button, then the unit will turn off.
9.16.6 During Cleaning operation, only the on/off, auto clean, swing, air direction, clear air and LED
display buttons are available.

9.17 Turbo

9.17.1 Under cooling mode (except Force Cooling mode), the indoor fan motor will run in Turbo speed
when receive the signal from remoter controller, and will get back to the presetting speed when receive
again.
9.17.2 The turbo mode will cancel and indoor fan motor will get back to the presetting speed when one
of following condition occur:
a. mode changed;
b. get into Force Cooling mode;
c. turn off the air conditioner;
9.17.3 Sleep mode is not available in this mode.

- 30 -
Service manual

- 31 -
Service manual

10 Model and Parameters


Model 7K 9K 12K
DELAY_TIME 127sec 127sec 127sec

DEFROST_TIME 7.5min 7.5min 7.5min

I3SEC 7.5 10.0 12.0

I5MIN 6.2 7.5 8.5

IFAN 5.2 6.0 7.5

IRESTORE 4.2 5.0 6.5

IDEFROST 3.2 3.5 5.0

TE1 28 28 34

TE2 32 32 37

TE3 30 30 33

TE4 26 26 22

TE5 4 4 4

TE6 10 10 10

TE7 60 60 63

TE8 53 53 53

TE9 50 50 52

THDEFROST 15 17 18

TMDEFROST 16 18 19

TLDEFROST 17 19 20

ANGLRANGE 196 196 196

ANGLOFF 100 100 100

ANGLCOOL 180 180 180

ANGLHEAT 22 22 22

ANGLCSL 8 8 8

ANGLCSH 40 40 40

ANGLHSL 8 8 8

ANGLHSH 40 40 40

ANGLDL 8 8 8

ANGLDH 190 190 190

ANGLFL 50 50 50

ANGLFH 155 155 155

HSPEEDH 1000 1080 1280

HSPEEDM 900 950 1060

HSPEEDL 800 800 900

HSPEEDS 750 750 750

CSPEEDP 1080 1080 1280

CSPEEDH 1040 1040 1260

CSPEEDM 900 900 1080

CSPEEDL 800 800 900

CSPEEDS 750 750 750

- 32 -
Service manual

Model 18K
DELAY_TIME 127sec

DEFROST_TIME 7.5min

I3SEC 17

I5MIN 15

IFAN 14

IRESTORE 12

IDEFROST 8.5

TE1 37

TE2 34

TE3 30

TE4 20

TE5 3

TE6 12

TE7 60

TE8 53

TE9 52

THDEFROST 19

TMDEFROST 20

TLDEFROST 21

ANGLRANGE 190

ANGLOFF 97

ANGLCOOL 174

ANGLHEAT 15

ANGLCSL 10

ANGLCSH 40

ANGLHSL 10

ANGLHSH 40

ANGLDL 10

ANGLDH 190

ANGLFL 60

ANGLFH 150

HSPEEDH 1280

HSPEEDM 1100

HSPEEDL 1000

HSPEEDS 900

CSPEEDP 1280

CSPEEDH 1250

CSPEEDM 1100

CSPEEDL 900

CSPEEDS 800

- 33 -
Service manual

11 Troubleshooting

11.1 LCD Display board

ON/OFF indicator

This indicator illuminates when the air conditioner is in operation.

AUTO indicator

This indicator illuminates when the indoor air exchange with the outdoor air.

TIMER indicator

This indicator illuminates when TIMER is set ON/OFF.

Ionizer(Clean air) indicator

This indicator illuminates when the ionizer function is activated.

PRE.-DEF. Indicator (For Cooling & Heating models only)

This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control

feature is activated in heating mode.

Turbo indicator

This indicator illuminates when the air conditioner is in turbo operation.

- 34 -
Service manual
Indoor fan indicator

This display is separated into three zones. Once the indoor fan is on, the zones illuminate gradually

DIGITAL DISPLAY indicator

Displaying the current set temperature when the air conditioner is in operation. When Self-Clean feature is
,, ,,
activated, it displays .

FAN SPEED indicator

This indicator illuminates when change the fan speed.

11.2 Indoor Unit Error Display


Display STATUS

E1 EEPROM error

E2 Zero-crossing examination error

E3 Fan speed beyond control

E4 Over current protection of the compressor occurs 4 times

E5 Open or short circuit of Room temperature sensor

E6 evaporator temperature sensor open or short circuit of

- 35 -
Service manual

11.3 Diagnostic chart

After energizing, no indicator is lighted and the air conditioner can’t be operated.

- 36 -
Service manual

11.4 Resetting phenomenon often occurs during operation.

(That is automatically entering to the status when power is on.)


The reason is that the instantaneous voltage of main chip is less than 4.5V. Check according to the following procedure:

Resetting phenomenon often occurs during operation.

Yes

After changing indoor PCB, check if the failure realease. Yes

Yes
Indoor PCB is defective.

After changing indoor fan motor, check if the failure realease.

YES

Power supply circuit has problems.

11.5 Indoor Unit Error Display:E3.

- 37 -
Service manual

11.6 Indoor Unit Error Display:E5 or E6

11.7 Indoor Unit Error Display:E4

11.8 Indoor Unit Error Display:E1

EEROM error, indoor PCB is defective.

11.9 Indoor Unit Error Display:E2

This is alarm signal when the main chip can’t detect over-zero signal. When such failure occurs, the main control board
must have fault.

- 38 -
Service manual

12 haracteristic of temperature sensor


Temp.℃ Resistance KΩ Temp.℃ Resistance KΩ Temp.℃ Resistance KΩ
-10 62.2756 17 14.6181 44 4.3874
-9 58.7079 18 13.918 45 4.2126
-8 56.3694 19 13.2631 46 4.0459
-7 52.2438 20 12.6431 47 3.8867
-6 49.3161 21 12.0561 48 3.7348
-5 46.5725 22 11.5 49 3.5896
-4 44 23 10.9731 50 3.451
-3 41.5878 24 10.4736 51 3.3185
-2 39.8239 25 10 52 3.1918
-1 37.1988 26 9.5507 53 3.0707
0 35.2024 27 9.1245 54 2.959
1 33.3269 28 8.7198 55 2.8442
2 31.5635 29 8.3357 56 2.7382
3 29.9058 30 7.9708 57 2.6368
4 28.3459 31 7.6241 58 2.5397
5 26.8778 32 7.2946 59 2.4468
6 25.4954 33 6.9814 60 2.3577
7 24.1932 34 6.6835 61 2.2725
8 22.5662 35 6.4002 62 2.1907
9 21.8094 36 6.1306 63 2.1124
10 20.7184 37 5.8736 64 2.0373
11 19.6891 38 5.6296 65 1.9653
12 18.7177 39 5.3969 66 1.8963
13 17.8005 40 5.1752 67 1.83
14 16.9341 41 4.9639 68 1.7665
15 16.1156 42 4.7625 69 1.7055
16 15.3418 43 4.5705 70 1.6469

- 39 -

You might also like