BioEntry W

Compact Outdoor Fingerprint Reader/Controller

Installation Guide
EN 101.00.BEW V1.30

www.supremainc.com
BioEntry W

Important Safety Information

Carefully review the information within the user manual before installing/operating the device.
Pay careful attention to the warning and cautions below as they are here to prevent any risk/damage to
any person(s) or property associated with the device.

Warning Caution
Failure to heed these warnings may lead to serious Failure to heed these cautions may lead to minor injury
injury or even death! or damage the device.

Installation Installation

 Do not install the device near heat sources such as radiators,  Do not install the device in a place subject to direct sun light,
heat registers, and stoves. humidity, dust or soot.
 Do not install the device near areas of large electromagnetic  Do not leave cables (especially power cables) exposed to
interference. the outer environment.
 Do not install the device near objects with a strong magnetic
field such as magnets, computer monitors (especially CRT),
TV screens and speakers.
 Secure I/O, the electrical locking device and access controller
Usage must use independent power source.

 Do not disassemble, repair or reconstruct the device. Usage


Contact your nearest Suprema dealer for technical support.
 Only use the device its intended use.  Do not drop or apply any physical shock/impact to the device.
 Regularly clean the product with a soft dry cloth; avoid
benzene or alcohol.

ⒸCopyright 2007 Suprema Inc. 2


BioEntry W

About Fingerprint Recognition 4


Contents
How to Enroll a Fingerprint on the Device 5
Components 7
Product Description 9
Dimensions 11
Cable Specifications 12
Installation 13
System Configurations 14
Connections 17
Resetting Network Settings 28
Electrical Specifications 29
Product Specifications 30
Troubleshooting 31
Precautions for Device cleaning 32
FCC Rules 33

ⒸCopyright 2007 Suprema Inc. ‹#›


BioEntry W

About Fingerprint Recognition

What is a fingerprint?
Fingerprints are individual’s own biometric information and do not change throughout one’s life. Fingerprint
recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from
the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing
PIN or cards.

What is fingerprint recognition?


Fingerprints consist of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is the
hollow between two ridges. Each individual has unique patterns of ridges and valleys; fingerprint recognition
makes use of these differences to differentiate between individuals.
Fingerprint sensors generate 2-dimentional fingerprint images using various technologies: optical, capacitive, or
thermal. Fingerprint template is a collection of numeric data representing the features of a fingerprint.
Fingerprint templates are saved inside the memory of BioEntry W, and used for identification.

Suprema’s Personal Information Protection Technology


To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is impossible
to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a
fingerprint.

ⒸCopyright 2007 Suprema Inc. 4


BioEntry W

How to Enroll a Fingerprint on the Device

Suprema's fingerprint products have outstanding recognition performance regardless of the user's fingerprint
condition or positioning. However pay careful attention to the following instructions to maximize the performance
of the device.

Fingerprint Enrollment
 It is recommended to enroll the index or middle finger.
The thumb, ring or little finger are generally more difficult to position properly.

How to place a finger on a sensor


 Fully cover or provide maximum contact to the surface of the sensor with the desired finger. People tend to
place the tip of a finger on the sensor; this will only provide a small area of the finger to be captured and will
result in poor performance.
 Place the core of the fingerprint near the center of the sensor. This will ensure a good template will be
created. The core of a fingerprint is a center where the spiral of ridges is most dense.

ⒸCopyright 2007 Suprema Inc. 5


BioEntry W

How to Enroll a Fingerprint on the Device

Fingerprint Enrollment Precautions

Operational Warnings
 If a finger is wet or too moist, wipe off the moisture then try the scan again.
 If a finger is covered with dust or impurities, clean the finger then try the scan again.
 If a finger is dry, breathe warm air onto the finger then try the scan again.

Solving Authentication Difficulties


 Delete then Re-enroll the finger.
 Enroll the same finger multiple times.
 Try a different finger with a more vivid fingerprint.
 Enroll various fingers for each user.

ⒸCopyright 2007 Suprema Inc. 6


BioEntry W

Components

 Basic Components

Diode (1)

Wall Mount Screws (2) Main Unit Mounting


Screws (2)

BioEntry W
Wall Mounting bracket (1) Software CD (1)

ⒸCopyright 2007 Suprema Inc. 7


BioEntry W

Components

 Optional Accessories

Secure I/O 12VDC Power Adaptor Plastic Stand USB Fingerprint


Scanner

ⒸCopyright 2007 Suprema Inc. 8


BioEntry W

Product Description

 Front

LED LED Device Status


 Displays the current status with
various colors. Green Successful Authentication

Red Failed Authentication

Pink Processing
RFID Scanner Flicker Blue/Sky-Blue
 Place an RFID card over the Standard Operation
Color per 2sec
scanner.
Flicker Red/Pink
Device Locked
Color per 2sec
Flicker Blue/Red
Discharged Internal Battery
Color per 2sec
Unable to Acquire an IP
Fingerprint Sensor Flicker Blue/Yellow
Address from the DHCP
 Place a finger on the surface of the Color per 2sec
Server.
sensor.
Flicker Red Color per Unit Malfunction. Contact Your
2sec Suprema Dealer/Distributor.
Flicker Yellow Color
Waiting for an Input
per 2sec
Flicker Yellow Color Requesting IP Address from
per 1sec the DHCP Server.

ⒸCopyright 2007 Suprema Inc. 9


BioEntry W

Product Description

 Rear and Bottom

Cables
 Wiegand Input/Output Cables
 Power Cables
 RS485 Cables
 Ethernet Connector
 Input Cables
 Relay Cables

LED
 Network Status LED

Network Reset Switch


 See "Resetting Network Settings (page 28)" for more details.

Star-shaped screw hole for fixing a body to a metal bracket

ⒸCopyright 2007 Suprema Inc. 10


BioEntry W

Dimensions

 BioEntry W  Wall Mounting Bracket

44 mm 50 mm 40 mm

172 mm 172 mm 157 mm

ⒸCopyright 2007 Suprema Inc. 11


BioEntry W

Cable Specifications

PIN Description Color


1 SWIN1 BROWN

2 SWIN0 PURPLE

3 ETH TXP WHITE

4 ETH TXN ORANGE

5 ETH RXP BLACK

6 ETH RXN YELLOW

7 POWER IN RED

8 POWER GND BLACK

PoE VB2 BLUE


9
PoE VB2 BROWN

PoE VB1 RED


10
PoE VB1 GREEN

11 485 TRXN YELLOW/WHITE STRIPE

12 485 TRXP BLUE/WHITE STRIPE

13 485 GND BLACK/WHITE STRIPE

14 WIEGAND GND WHITE/BLACK STRIPE

15 WIEGAND D1 WHITE

16 WIEGAND D0 GREEN

17 NC PINK

18 RELAY NC ORANGE/WHITE STRIPE

19 RELAY COM GREEN/WHITE STRIPE

20 RELAY NO GRAY/WHITE STRIPE

ⒸCopyright 2007 Suprema Inc. 12


BioEntry W

Installation

1. Fix the wall mounting bracket on a wall by 3. Fix the device to the wall mounting bracket using the
using wall mounting screws. star-shaped screws.

2. Hook the device on the wall mount bracket.

Star-shaped
screw

Wall
Mount
Screws

ⒸCopyright 2007 Suprema Inc. 13


BioEntry W

System Configurations

 Standard

Door Sensor

Door Lock Exit Button

BioEntry W

LAN

PC USB Fingerprint
Scanner

ⒸCopyright 2007 Suprema Inc. 14


BioEntry W

System Configurations

 Secure (Secure I/O)


RS485

Door Sensor

Door Lock Exit Button

Secure I/O
BioEntry W

LAN

USB Fingerprint
PC
Scanner

ⒸCopyright 2007 Suprema Inc. 15


BioEntry W

System Configurations

 Network

Door Zone 1 (Anti-passback)

RS485 RS485

Secure I/O
FaceStation
BioEntry W BioEntry W

LAN

PC Server USB Fingerprint


Scanner

PC Client
FaceStation Secure I/O BioEntry W Exit Button

RS485
PC Client
Door Zone 2 (Anti-passback)

ⒸCopyright 2007 Suprema Inc. 16


BioEntry W

Connections

 Power Connection

DC Power
DC Power Supply
UPS
Supply (Optional)

Recommended Power Specifications


− 12V ±10%, at least 1500mA.
− Comply with standard IEC/EN 60950-1.
− Secure I/O, the electrical locking device and access controller must use independent power source.

ⒸCopyright 2007 Suprema Inc. 17


BioEntry W

Connections

 Ethernet Connection (Connection with HUB)


The device can be connected with a regular hub or PoE hub by connecting the Ethernet cable to the Ethernet
terminal. PoE(Power over Ethernet) is an Ethernet connection of which the power is supplied from PSE(Power
Sourcing Equipment) satisfying the IEEE802.3af standard.

Ethernet Hub

ⒸCopyright 2007 Suprema Inc. 18


BioEntry W

Connections

 Ethernet Connection (Direct connection with PC)


Use a standard CAT-5 cable to connect the device directly to a PC.
BioEntry W supports auto MDI/MDIX, therefore a crossover cable is not necessary.

ⒸCopyright 2007 Suprema Inc. 19


BioEntry W

Connections

 RS485 Connection for Host Communication

Power IN (Red)
Power GND (Black)
GND - Signal GND (Black/White Stripe)
TRX+ TRX+ (Blue/White Stripe)
TRX- TRX- (Yellow/White Stripe)

RS232-485 BioEntry W
Converter

Power IN (Red)
Power GND (Black)
Signal GND (Black/White Stripe)
TRX+ (Blue/White Stripe)
TRX- (Yellow/White Stripe)

BioEntry W

Notes
− Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter,
refer to the converter’s manual.
− Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be
necessary to lower the baudrates.
− The GND signal may be omitted if and only if the GND potential difference is less than ±5V.

ⒸCopyright 2007 Suprema Inc. 20


BioEntry W

Connections

 RS485 Connection for Secure I/O

Power IN (Red) Power IN (Red)


Power GND (Black) Power GND (Black)
Signal GND (Black/ White Stripe) Signal GND (Black/White Stripe)
TRX+ (Blue/ White Stripe) TRX+ (Blue/White Stripe)
TRX- (Yellow/ White Stripe) TRX- (Yellow/White Stripe)

BioEntry W BioEntry W

TRX GND - TRX GND -


TRX+ TRX+
TRX- TRX-

Secure I/O Secure I/O

Notes
− For bus termination, only the devices at both ends of the bus should be terminated.
− Maximum numbers of devices in an RS485 loop are two(2) Suprema devices and four Secure I/Os.

ⒸCopyright 2007 Suprema Inc. 21


BioEntry W

Connections

 Relay Connection – Fail safe lock

BioEntry W

(20) Relay NO (Gray/White Stripe)


(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe)

• N.O. (Normally Open): A control signal closes the circuit.


• N.C. (Normally Closed): A control signal opens the circuit.
• Take care of the direction of the diode.
• Make sure to install the diode near to the door lock.
• Make sure to use different power supplies for the BioEntry W and
the door lock.
• Make sure to install the diode at both ends of the circuit as shown
+ - in the figure left in order to protect the relay contact from the
reverse current that occurs when the door lock works.
Deadbolt / DC
Door strike Power supply

ⒸCopyright 2007 Suprema Inc. 22


BioEntry W

Connections

 Relay Connection – Fail secure lock

BioEntry W

(20) Relay NO (Gray/White Stripe)


(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe)

• N.O. (Normally Open): A control signal closes the circuit.


• N.C. (Normally Closed): A control signal opens the circuit.
• Take care of the direction of the diode.
• Make sure to install the diode near to the door lock.
• Make sure to use different power supplies for the BioEntry W and
the door lock.
• Make sure to install the diode at both ends of the circuit as shown
+ - in the figure left in order to protect the relay contact from the
Deadbolt / DC reverse current that occurs when the door lock works.
Door strike Power supply

ⒸCopyright 2007 Suprema Inc. 23


BioEntry W

Connections

 Relay Connection - Automatic door

RTE Switch

Presence
Detector

BioEntry W

Automatic (20) Relay NO (Gray/White Stripe)


RTE Switch
Door (19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe)

ⒸCopyright 2007 Suprema Inc. 24


BioEntry W

Connections

 Digital Input Connection (RTE/ Door sensor)

BioEntry W

(13) 485 GND (Black/White Stripe)


(1) Input 1 (Brown)
Door Status (13) 485 GND (Black/White Stripe)
(2) Input 0 (Purple)

Request TO
Exit

ⒸCopyright 2007 Suprema Inc. 25


BioEntry W

Connections

 Digital Input Connection (Alarm/ Emergency switch)

BioEntry W

(13) 485 GND (Black/White Stripe)


(1) Input 1 (Brown)
Switch #1 (13) 485 GND (Black/White Stripe)
(2) Input 0 (Purple)

Switch #2

ⒸCopyright 2007 Suprema Inc. 26


BioEntry W

Connections

 Wiegand Input

RFID Reader BioEntry W

GND (14) Wiegand GND (White/Black Stripe)


Wiegand D1 (15) Wiegand D1 (White)
Wiegand D0 (16) Wiegand D0 (Green)

 Wiegand Output

Controller BioEntry W

GND (14) Wiegand GND (White/Black Stripe)


Wiegand D1 (15) Wiegand D1 (White)
Wiegand D0 (16) Wiegand D0 (Green)

ⒸCopyright 2007 Suprema Inc. 27


BioEntry W

Resetting Network Settings

In case of forgetting network setting of the device (TCP/IP or RS-485 setting) during installation or using the
device, you can initialize network setting (TCP/IP or RS-485 setting) by using the network reset switch on the
back panel of the device. Please refer to the figures as below.

1. Turn on the device.

2. Press and hold the network reset switch until the device
turns off. (Then, the device will restart.)

Network Default Setting


 TCP/IP Address : 192.168.0.1

 Not checked “Use Server”

 RS-485 : PC Connection, 115200bps

3. Modify then save the TCP/IP or RS485 settings.

4. Reboot the device.


Network Reset
5. Confirm the new settings. Switch

ⒸCopyright 2007 Suprema Inc. 28


BioEntry W

Electrical Specifications

Min. Typ. Max. Notes

Voltage (V) 10.8 12 13.2 Use regulated DC power adaptor only.


Power
Current Consumption
- 260
(mA)

VIH (V) 2.0 - 10.0

Switch Input VIL (V) - - 0.4

Pull-up resistance (Ω) - 4.7k - The input ports are pulled up with 4.7k resistors.

VOH (V) - 5 -

TTL/ VOL (V) - 0.8 -


Wiegand Output
The outputs ports are open drain type, pulled up
Pull-up resistance (Ω) - 4.7k -
with 4.7k resistors internally.

Voltage - - 24 VDC
Relay
Current - 0.5 A 1.0 A

ⒸCopyright 2007 Suprema Inc. 29


BioEntry W

Product Specifications

Max Users 5000 users (10,000 templates) [1:1 & 1:N]

Log Capacity 50,000 logs

CPU 533MHz DSP

Memory 8MB Flash + 8MB RAM


System
125KHz HID Prox, 13.56MHz Mifare/DESFire
RF Options
13.56MHz iCLASS SE/Felica

Interfaces TCP/IP, RS485, Wiegand

Input / Output 2 TTL Inputs, 1 Relay Output

Power 12VDC, PoE (Power over Ethernet)

BioEntry W
50 x 172 x 44 mm
(W x H x D)
General Dimensions
Wall Bracket
40 x 157 mm (screw joint included)
(W x H)

ⒸCopyright 2007 Suprema Inc. 30


BioEntry W

Troubleshooting

Please contact your local dealer/distributor for support or contact Suprema at [email protected].
Please submit the following information and we will coordinate support with your local dealer/distributor.

 Device model
 F/W version of the device
 H/W version of the device
 Detailed information regarding the issue
 Error messages / screenshots, if possible
 Contact information (Company, Name, Telephone, Email)

ⒸCopyright 2007 Suprema Inc. 31


BioEntry W

Precautions for Device Cleaning

 Wipe out the device surface with dry towel or cloth.


 Use a soft dry towel when removing dust or impurities from the surface of the sensor.
 Cleaning the sensor with a detergent, benzene or thinner will damage the surface and disrupt the unit's
ability to properly read a fingerprint.

ⒸCopyright 2007 Suprema Inc. 32


BioEntry W

FCC Rules

 Caution
Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the
user’s authority to operate the equipment.

 Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interface, and (2) this device must accept any interface received, including
interference that may cause undesired operation.

 Information to User
This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more the following measures:

1. Reorient / Relocate the receiving antenna.


2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.

ⒸCopyright 2007 Suprema Inc. 33


㈜슈프리마
경기도 성남시 분당구 정자동 파크뷰 오피스타워 16층
Tel : 031-783-4510
Fax : 031-783-4503
온라인고객지원 : [email protected]
회사홈페이지 : www.suprema.co.kr
제품홈페이지 : www.biostation.co.kr

BioEntry Plus의 기능 및 사양은 제품의 품질 향상이나 기능 수정 등으로 인해 예고 없이 변경될 수 있습니다.


제품에 대한 자세한 사항은 ㈜슈프리마로 문의 바랍니다.

You might also like