Apex TR
Apex TR
Easy to Install
• Sensor can be remotely mounted
Apex takes all the best elements of gas
•
up to 100m from the transmitter
On board relays allow for local audible/ detection design and combines them into one
•
visual alarms
Strong integral 316 STST mounting bracket unit. Apex provides the highest performance,
installation flexibility, a wide range of
• Large easy access cable entries
• Easy access terminal blocks
• Wide range of accessories
Easy to Use
accessories and a choice of communication
• Intuitive menu operating system outputs. All this is provided in a package
• Clear on screen instructions guide user
• Simple for button operation that is easy to install, operate and maintain.
• Multiple language options
• Transmitter recognizes new sensor
cartridges Typical applications include: Transmitter
• Easy to change gas types Petrochemical The robust hazardous area approved Apex
• Large clear backlit graphical LCD display Exploration drilling rigs, production platforms, transmitter housing and mounting bracket is
FPSO’s, oil and gas terminals, chemical plants, made from 316 Stainless Steel. It has a large
Easy to Maintain backlit LCD display, simple 4 button operation,
oil and gas tankers
• Simple plug in under power sensor cartridge 3 fully configurable relay outputs and selectable
• Smart cartridges are supplied pre calibrated Heavy Industrial sink, source or isolated 4-20mA signal. The
• Common transmitter for all gas types Steel manufacture, ship building transmitter is common to all types of sensor.
• Simple filter replacement Manufacturing
Automotive, glass and ceramics, aerospace, Sensor
printing and coating, cosmetics The Apex Sensor can be mounted directly on the
Pharmaceutical transmitter or remotely up to 100m away. There
Research labs, solvent storage areas, process areas, are two versions of sensor; one for both catalytic
demineralisation plants and electrochemical type sensor cartridges and
one for the thick film (semi conductor) type
cartridges.
Smart cartridge
The sensors can be fitted with a choice of over
40 toxic gas ranges and wide range of detectable
flammable gases. Each cartridge is pre calibrated
and simply plugs into the sensor. The Intrinsically
Safe design allows cartridges to be changed with
the unit under power. The transmitter recognizes
a newly fitted sensor cartridge and automatically
reads all the configuration information from it.
General specification
General Specification
Power supply 24Vdc nominal (18-32Vdc)
Power consumption (typical) Apex 3W toxic, 4.6W catalytic, 4.6W thick film
Outputs
Relay outputs A1, A2 and Fault 2A at 30Vdc* selectable normally open or normally closed and normally energised or normally de-energised
Analogue signal 4-20mA sink, source or isolated output
Digital output LonWorks (optional) – only available on ATEX certified version
Stability (typical)
Temperature: <±5% FSD (zero), <±5% FSD (span)
Time: <±3% FSD / year (zero), <±4% FSD / year (span)
Approvals CE Approved to all applicable European directives. EMC EN50270: 1999 type 2
Performance standards Exam (DMT) EN50054/50057/50271. CSA C22.2 No.152 (with cartridge 2110B3754)
Certification ATEX II 2G EEx d ia IIC, CSA Class 1, Division 1 groups B, C and D C22.2 No.152
UL Class 1, Division 1 groups B, C and D, and Class 1, Zone 1 AExd [ia] IIC
ATEX and UL T4 -40 to +80°C (-40 to +176°F), T5 -40 to +55°C (-40 to +131°F)
CSA T4 -40 to +75°C (-40 to +167°F), T5 -40 to +55°C (-40 to +131°F)
* CSA / UL rating 1A at 28Vdc
Available gases and ranges*
Gas Formula Ranges Cell type
Flammable Various 0-100%LEL or 0-10%LEL CAT/TF
Ammonia NH3 0-50ppm, 0-100ppm, 0-400ppm or 0-1000ppm ECC/TF
Arsine AsH3 0-0.2ppm ECC
Boron trichloride BCI3 0-6ppm ECC
Bromine BR2 0-0.4ppm ECC
Carbon monoxide CO 0-100ppm, 0-200ppm or 0-500ppm ECC
Chlorine Cl2 0-2ppm, 0-5ppm or 0-15ppm ECC
Chlorine dioxide ClO2 0-0.4ppm ECC
Diborane B2H6 0-0.4ppm ECC
Dichlorosilane SiH2Cl2 0-10ppm ECC
Ethylene oxide C2H4O 0-4ppm or 0-50ppm ECC
Fluorine F2 0-4ppm ECC
Germane GeH4 0-0.8ppm ECC
Hydrogen H2 0-1000ppm ECC
Hydrogen bromide HBr 0-12ppm ECC
Hydrogen chloride HCl 0-20ppm ECC
Hydrogen cyanide HCN 0-20ppm ECC
Hydrogen fluoride HF 0-12ppm ECC
Hydrogen sulfide H2S 0-15ppm, 0-20ppm, 0-50ppm or 0-100ppm ECC/TF
Nitric oxide NO 0-100ppm ECC
Nitrogen dioxide NO2 0-12ppm ECC
Oxygen O2 0-21%V/V ECC
Ozone O3 0-4ppm ECC
Phosphine PH3 0-1.2ppm ECC
Silane SiH4 0-20ppm ECC
Sulfur dioxide SO2 0-8ppm, 0-15ppm, 0-50ppm ECC
CAT- Electrocatalytic, ECC- Electrochemical Cell, TF- Thick Film Semi Conductor
*For other gases and ranges not listed contact Honeywell Analytics. * Oxygen detection products must only be used to
detect oxygen depletion in air.
As World leaders in gas detection solutions, Honeywell Analytics’
Sieger systems provide the most efficient, practical and
cost-effective fixed-point equipment. Wherever protection is
required from flammable or toxic gases, you can rely on our
equipment to provide practical solutions and to help keep
your business running safely and profitably.
Searchpoint
Apex Searchline Excel Optima Plus Signalpoint System 57
Typically used in the oil and Searchline Excel Cross DuctTM Designed for use in potentially Signalpoint is a self-contained The System 57 controller
gas distribution, petroleum is an open path infrared gas explosive atmospheres gas sensor system for either provides display and alarm
extraction and chemical detector for the detection of in harsh environmental combustible or toxic gases, facilities for the full range of
manufacturing industries, Hydrocarbons within HVAC air conditions, SearchPoint designed to make installation gas detectors. It comprises
the Apex gas detector and intakes and ventilation ducting Optima Plus is ideal where simple and maintenance a rack unit with mounting
transmitter functions across systems up to 5 meters speed of response, reduced minimal. Constructed options for channel control
a wide range of detectable in width. maintenance and failsafe in strong plastic, it is cards and interface cards.
flammable and toxic gases. operation is essential. particularly suited for indoor
With its rugged 316 stainless It is based on the proven Common applications include applications in light industrial
steel enclosure, it is especially Searchline Excel, which offshore platforms, production environments.
suited for extreme conditions, covers ranges up to 200m. storage and offloading
and provides a cost-effective vessels, and oil and gas
gas detection solution for a ClearShieldTM glass coating, terminals.
wide range of applications. infrared beam and heated
optical surfaces all combine
to reduce downtime and
increase system availability.
Please Note:
While every effort has been made to ensure
accuracy in this publication, no responsibility
can be accepted for errors or omissions.
Data may change, as well as legislation, and you
are strongly advised to obtain copies of the most
recently issued regulations, standards, and guidelines.
This publication is not intended to form the
basis of a contract.
© 2005 Honeywell Analytics
H_Apex DS_V1
12/05
© 2005 Honeywell Analytics
Thank you for reading this data sheet.
For pricing or for further information, please contact us at our UK Office, using the details
below.
UK Office
Keison Products,
P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England.
Tel: +44 (0)1245 600560
Fax: +44 (0)1245 808399
Email: [email protected]
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the
suitability of this product.