ColdBlock Brochure May24
ColdBlock Brochure May24
new standard
for sample digestion
TM
A superior alternative
to conventional methods.
Digestions are completed
in minutes with accuracy
and precision.
Introducing ColdBlock
ColdBlock digestion
technology is the Cooling zone
promotes
first and only sample condensation and
sample retention
Accurate recovery
of elements
digestion technology and reduced
digestion time
multi-element analysis.
Benefits for Your Lab
SPEED SIMPLICITY
What would a reduction in ColdBlock can be set up by
digestion time from hours a single person in less than
to minutes do for your lab 30 minutes.
workflow and productivity?
Simple software controls make
Digestions using ColdBlock it possible to save and reuse
have an average cycle time of multiple digestion methods.
10-40 minutes, significantly
faster than microwave or Maintenance and cleaning
hot plate. Bulk handling requirements are less than
of samples (load/unload) 10 minutes per week.
adds further efficiency.
SAFETY SAVINGS
ColdBlock eliminates the Shorter digestion, faster
need for hazardous throughput and shorter cycle
perchloric acid. time leads to a significant
increase in lab productivity.
Safe open-air operation
within a vent hood requires Customers report a 10-30%
no pressurization. A cooling reduction in costs compared
zone allows for safer handling to hot block and microwave
of test tubes. No time- sample digestion methods.
consuming pressurization/
depressurization steps
are required.
spending is required.
Tablet Interface
System Requirements:
VENTILATION Test Tube Stand Digester Chiller
ColdBlock digesters operate within
a fumehood with a draw of at least
400 cu ft./min.
Controller
COOLING
Connection to a recirculating chiller with
a minimum of 1200W cooling capacity
at 20° Celsius is also required.
ELECTRICAL
The Controller requires a 30 AMP
and 208-240V at 50/60 Hz.
System Configurations
Pro Series Model Small Sample Medium Sample Large Sample
# Samples 20 16 12
# of Tubes Included 40 32 24
Test Tube Diameter 28 mm 36 mm 52 mm
Test Tube Volume 50 ml 125 ml 250 ml
Typical Acid Volume 7-25 ml 16-50 ml 20-160 ml
Typical Sample Size 0.1-2.0g 0.25-5.0g 5-30g
Single Digester Footprint H 33cm x W 24.1cm x L 58.4cm H 34.9cm x W 24.1cm x L 58.4cm H 36.2cm x W 24.1cm x L 58.4cm
Controller H 61cm x W 20.3cm x L 61cm
Chiller H 55.9cm x W 38.1cm x L 66cm
Power Requirement Single Phase 240V and 50/60Hz
Circuit Requirement 30A for single / dual configuration,50A for triple / quadruple configuration
Chiller 1100W chiller with -5 degree capacity
1 chiller per 1-2 digesters
Ventilation Standard vent hood; 400 cu. ft./min.
ColdBlock’s sample digestion
system is being used in
laboratories across several
industries in locations
around the world.
Let’s Connect!
Learn more about how ColdBlock
can revolutionize your lab!
coldblock.ca/CIM-2024