0% found this document useful (0 votes)
77 views

AX2 Data Sheet

The document describes the Acclarix AX2 series diagnostic ultrasound system. It provides details on the system's dimensions, weight, monitor, transducer port, battery specifications, and imaging features. The system is designed to deliver high performance and innovative features at an affordable price point for point-of-care and general imaging applications.

Uploaded by

guxiang0831
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views

AX2 Data Sheet

The document describes the Acclarix AX2 series diagnostic ultrasound system. It provides details on the system's dimensions, weight, monitor, transducer port, battery specifications, and imaging features. The system is designed to deliver high performance and innovative features at an affordable price point for point-of-care and general imaging applications.

Uploaded by

guxiang0831
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Acclarix AX2 Series

Diagnostic Ultrasound System


Datasheet
Acclarix AX2 series Diagnostic Ultrasound System

Product Description Dimensions and Weight

The remarkable Acclarix AX2 series Compact Dimension: 375 mm×380 mm×58 mm
Ultrasound System delivers a powerhouse Net Weight (No Battery): 4.2kg (1 transducer port)
combination of features to meet the demands of Net Weight (1 battery): 4.65 kg (1 transducer port)
point of care and general imaging applications.
The Acclarix AX2 series has been designed f rom Monitor
the ground up with a relentless focus on
delivering unexpected levels of innovation and • 15.6’’ high resolution LCD monitor
performance at a price point that is equally • Resolution: 1920 x 1080
surprising. One active transducer port design • Image Size: 1040 780
enables switching transducer seamlessly at a • Open angle: 0° - 180°
f inger tip Dual batteries extend the imaging • Magnetic latch closure
scanning. Extremely light body embodied with • Built-in stereo speaker
brand new EIS operating system empowers • Brightness and Contrast adjustable
smooth system operation and fast system
response. Transducer Port

Advanced Technique and Features • One active transducer port


• Single transducer port configurable
• TAI Tissue Adaptive Imaging
• eSRI Adaptive Speckle Reduction Imaging Battery
• Frequency Compounding Imaging
• Adaptive Spatial Compounding Imaging • Rechargeable
• Harmonic Imaging • Max. two batteries configurable
• B mode Auto Optimization • 5000mAh capacity for each battery
• Digital Multi-Beam forming • Removable
• Trapezoid Imaging • Approximately 1 hour of typical ultrasound
• Adaptive Doppler imaging exam use for one fully charged battery.
• Spectrum Enhancement • Approximately 2 hours of typical ultrasound
• B Steer exam use for two fully charged batteries.
• Digital Zoom • Standby time: > 4 hours (two batteries)
• Auto Doppler trace • One battery fully charged in about 2.5 hours
• Two batteries fully charged in about 5 hours
System Overview • Battery indicator on the console near the handle
• Battery level icon displayed on the main screen
System Architecture
AC Power Requirements
Physical Channels: 64
Beam Forming: Quad beam Voltage: 100-240 V~
Processor: ARM Frequency: 50Hz/60 Hz
Memory: 2 GB
Hard Drive: 120G SSD
Operating System: Android
System Boot-up: About 30s
Boot-up from sleep: 5s
Shutdown: 3s

01.
Acclarix AX2 series Diagnostic Ultrasound System

Environment Requirements System Ergonomic Design

Operating Environment Handle

Ambient temperature: 0° to 40°C Provides wrist support during imaging


Relative Humidity: 15%~95% (no condensing)
Atmospheric pressure: 86kPa-106kPa Magnesium alloy body

Storage Environment Extremely light weight realizes the true portability.

Ambient temperature: -20° to 55°C User Interface


Relative Humidity: 15%~95% (no condensing)
Atmospheric pressure: 70kPa-106kPa Control Panel

Language Supported • Interactive back-lighting


• Hard Keys provides tactile feedback
• English • User-defined keys
• Chinese
Touch Screen
I/O Ports
• 10.1” Touch screen
• S-Video • Gesture-control
• USB 3.0 • Virtual TGC sliders
• HDMI • Support QWERTY keyboard for text input
• Ethernet • Brightness adjustable

Options Main Screen Display

• Transducers Information Field


• Needle Guide Bracket Kits
• Printers - EDAN logo
• Battery - Hospital name
• USB Disk - Date
• WiFi - Time
• Footswitch - Patient ID
- Single button/Double buttons - Patient Name
- User-defined Functions (Freeze, Save, Print) - Patient Gender
• Simple Cart: MT-808 - Patient Age
- Height Variable - Transducer model
- A drawer for glossary storage - Exam Preset
- A shelf for Video printer
- 4 transducer holders and 2 gel holders with
removable silicon cover
- Cable manager
- Drawer height and position adjustable
• Suitcase

02.
Acclarix AX2 series Diagnostic Ultrasound System

Image Field Exam Presets

- Mechanical Index (MI) • System pre-defined exam presets include


- Thermal Index (TI) (Transducer specific):
- Imaging parameters - ABD
- Gray Scale bar - Abd Difficult
- Depth Scale - Aorta
- Center Mark - Lung
- Measured result window - FAST
- TGC curve - Early OB
- OB
Mini Report - Fetal Echo
- GYN
- Measurement and calculation results - IVF
- Measurement and calculation results for multiple - Urology
fetus - Prostate
- Thyroid
Thumbnail Field - Breast
- Testis
- All captured static images and cline clips - Carotid
- Shortcut keys for selecting, viewing, deleting, - Up Ext A (Upper Extremity Artery)
exporting images. - Up Ext V (Upper Extremity Vein)
- Low Ext A (Lower Extremity Artery)
User Feedback Field - Low Ext V (Lower Extremity Vein)
- Vascular Access
- Illustration of trackball and trackball keys - Spine
- Cine bar - MSK
- Exit icon for exiting RawData review status - Sup MSK (Superficial MSK)
- Nerve
Status Bar - Sup Nerve (superficial Nerve)
- Shoulder
• Utility Icon (access to Utilities function) - Adult Cardiac
• Image Store Icon - Pediatric Cardiac
• USB Icon - TCD
• Printer Icon • User customizable presets: Copy, Delete, Save
• WiFi Icon as and rename
• Network Transfer Status Icon • Exam presets are configurable in Set-up
• Hard Drive Icon • Supports a second page, up to 30 presets per
• Battery Icon transducer
• Each preset can share comment, body mark,
and measure presets

03.
Acclarix AX2 series Diagnostic Ultrasound System

Annotations Imaging Parameters

Comments B-mode (Live imaging)

• User-programmable home position Image Type Detail/General/Penetration


• Arrow with user controlled orientation Auto TGC, Gain
• QWERTY keyboard Digital Zoom x0.8-x2.0,
• Block move and delete for separate blocks x0.5-x16.0 (Tender)
of text Display Depth 1-45cm
• Smart text replacement for predefined text Frequency 1-17MHz,
(e.g., Log replaces Trans with one keystroke) 1-19 MHz (Tender)
• 310 pre-defined comments 3 fundamental +2 harmonic
• User customizable 5 fundamental +5 harmonic
(tender)
Body Mark eSRI Off, Low, Med, High
FOV Small, Med, Large, Full
• Up to 100 Body Mark graphics in library Steer 0°,±10°
Gain 0-100dB
Imaging 0-260dB (tender)
TCG 8 segments
Imaging Modes Dynamic Range 40-96dB
20-320 dB (tender)
B-mode Line Density Low, Med, High
M-mode Max. Frame Rate 551f/s, depends on transducer
Color Doppler Map 11 Types
PDI/DPDI 20 Types (tender)
PW Doppler Persistence Off, Low, Med, High
CW Doppler Focus Position Max. 16 positions, adjustable
Focus Number 1-3, adjustable
Display Modes: Dual Imaging 1-4, adjustable
Colorize On, Off
• Available for B and Color (PDI/DPDI) mode. Tint 5 Types
• Displays two image side-by-side, two frozen 20 Types (tender)
or one active/one frozen. Up/Down Flip
• Allows to switch between two images Left/Right Flip
Spatial Compounding On, Off (max 3 angles)
Imaging Mode Combinations Trapezoid On, Off
Acoustic Power 10%-100%
• B+M
• B/C (PDI or DPDI), Single
• B/C (PDI or DPDI), Dual
• B+B/C (PDI or DPDI), Dual live
• B+PW (Duplex)
• B+PW (Update)
• B/C (PDI or DPDI)+PW (Triplex)
• B/C (PDI or DPDI)+PW (Update)
• B+CW (Update)
• B/C (PDI or DPDI)+CW (Update)

04.
Acclarix AX2 series Diagnostic Ultrasound System

B-mode (Post-processing & retrospective) Color/PDI/DPDI Mode (Live imaging)


• Gain Image Type HighFlow/MidFlow/LowFlow
• TGC Dual Live
• Zoom ROI size/position
• Dynamic Range Frequency 2 levels
• eSRI 5 levels (tender)
• Colorize Gain 0-100dB
• Map Line Density Low, Med, High
• Up/Down Flip Dynamic Range 10-70 dB
• Left/Right Flip Not available for Color mode
Max. Frame Rate 257f/s, depends on transducer
Persistence Off, Low, Med, High
M-mode (Live imaging) Smooth Off, Low, Med, High
Wall Filter Low, Med, High
Sweep Speed Fast/High/Med/Low/Slow Color Map 8 Types
Corresponds to sweep time 20 Types (tender)
of 1s, 2s, 4s, 8s, and 12s per Steer Angle 0°±10°, ±20° (L12-5Q, General)
screen respectively. 0°±15°, ±30° (L12-5Q, thyroid)
Line Persist Off, Low, Med, High 0°,±5°, ±10° (L17, 7Q)
Map 11 Types 0°,±10°,±20° (L17-7HQ)
Colorize On, off PRF 0.6-11.4kHz
Tint 5 Types Baseline 25 levels
20 Types (tender) (Not available for PDI mode)
Gain 0-100dB Threshold 0-100
0-260dB (tender) Invert On, Off
Frequency 1-17 MHz (Not available for PDI mode)
1-19 MHz (tender) Acoustic Power 10%-100%
3 fundamental+2 harmonic
5 fundamental+5 harmonic
(tender)
Dynamic Range 40-96 dB
20-320 dB (tender)
Strip size Full, large, Med., small
Side-by-side On (Left/Right)
Off (Up/Down)
Acoustic Power 10%-100%

M-mode (Post-processing & retrospective)

• Gain
• TGC
• Dynamic Range
• Colorize
• Map
• Stripe Size
• Side-by-side

05.
Acclarix AX2 series Diagnostic Ultrasound System

Color/PDI-DPDI Mode (Post-Processing & PW Mode


Retrospective) (Post Processing & Retrospective)
• Zoom • Gain
• Color map • Dynamic Range
• Invert (Not available for PDI mode) • Colorize
• Baseline • MAP
• Baseline
• Angle Correct
PW-mode (Live imaging) • Invert
• Strip size
Image Type HighFlow/MidFlow/LowFlow • Auto trace
HPRF Automatic invocation to • Trace side
maintain gate location/scale
Auto Trace
Trace Side Up, down, both
Duplex CW-mode (Live imaging)
Triplex
Frequency 2 levels Image Type HighFlow/MidFlow/LowFlow
5 levels (tender) PRF 1-100 kHz
PRF 0.9-14.7kHz Gain 0-100dB
Gain 0-100dB Dynamic Range 10-70 dB
Dynamic Range 10-70 dB Wall Filter Low, Med, High
Wall Filter Low, Med, High Sweep Speed Fast, High, Med., Low, Slow
Sweep Speed Fast/High/Med/Low/Slow Corresponds to sweep time
Corresponds to sweep time of 2s, 3s, 4s, 6s and 8s per
of 2s, 3s, 4s, 6s and 8s per screen respectively.
screen respectively. Baseline 9 levels
Baseline 9 levels Angle Correction -80° to 80°
Angle Correction -80° to 80° Quick Angle -60°/0°/60°
Quick Angle -60°/0°/60° Invert
Steer 0°,±10°,±20° (L12-5Q) Volume 0-99
0°,±5°,±10° (L17-7Q) Map 11 Types
0°,±10°,±20° (L17-7HQ) Colorize On, Off
Invert Tint 5 Types
Volume 0-99 20 Types (tender)
Map 11 Types Strip Size Full, Large, Med., Small
Colorize On, Off Acoustic Power 10%-100%
Tint 5 Types
20 Types (tender)
Gate Size 0.5-20 mm

Strip size Full, Large, Med., Small


Acoustic Power 10%-100%

06.
Acclarix AX2 series Diagnostic Ultrasound System

CW Mode (Post Processing &


Retrospective)

• Gain
• Dynamic Range
• Colorize
• Map
• Baseline
• Angle Correct
• Invert
• Strip Size

Review and Post Processing functions

Cine Review
• Frame by frame manual review
• Auto playback with 6 level speed adjustable
• Start frame and end frame are selectable for
cine loop review
• Independent cine review in Dual mode.
• Maximum cine memory depends on
transducers and image parameters:
- 200000 frames for B mode
- 35000 frames for Color mode
- 180s for M mode
- 240s for PW/CW Doppler mode

Post-Processing Features

All the image/cine are stored in Raw Data format in


local disk. The following Post Processing features
are available when in image/cine review of current
exam or the stored exam.

• Adjusting imaging parameters


• Storing static image/ cine loop

07.
Acclarix AX2 series Diagnostic Ultrasound System

Transducers and Biopsy Guide


Transducer Applications
Transducer Applications Transducer Applications

Abdomen Fetal / Obstetrics


Fetal / Obstetrics Gynecology
C5-2Q Urology E8-4Q Transvaginal
Gynecology Transrectal
Musculoskeletal Urology

Small parts Adult Cardiac


Peripheral Abdomen
Vascular Pediatric Cardiac
L12-5Q Musculoskeletal P5-1Q Adult Cephalic

Small Parts Small Parts


L17-7Q Peripheral L17-7HQ Peripheral
Vascular Vascular
Musculoskeletal Musculoskeletal

Transducer C5-2Q P5-1Q L12-5Q E8-4Q L17-7Q L17-7HQ*


Transducer Convex Phased Linear Endocavity Linear Linear
Type
Bandwidth 1-7MHz 1-5MHz 3-13MHz 3-12MHz 4-19MHz 4-19MHz
@-20dB
Bandwidth 2-5MHz 1-5MHz 5-12MHz 4-8MHz 7-17MHz 7-17MHz
@-6dB
Elements 128 64 128 128 128 192
Footprint NA 16mm 38mm NA 38mm 38mm
Convex 60mm NA NA 10mm NA NA
Radius
FOV 60° 90° NA 150° NA NA
Display 45cm 30cm 11cm 14cm 11cm 11cm
Depth
Max. PW 9m/s 10m/s 4.7m/s 5m/s 3.2m/s 3.2m/s
Velocity(±60°)
Max. CW NA 75m/s NA NA NA NA
Velocity(±60°)
Biopsy Guide Yes No Yes Yes Yes No
Cable Length 2m 2m 2m 2m 2m 2m
08.
Acclarix AX2 series Diagnostic Ultrasound System

Biopsy Guide

Needle Guide

- Supports guide lines of multiple angles.


- Support guide line calibration.

Center Line

- Center Line is a vertical dotted line displayed at


the middle of the image field, representing the
middle of ultrasound beam It helps to locate the
position and depth of a target disease focus for
out of plane biopsy, lithotripsy and etc.

Supported Needle Guided Brackets

Model Angle/Depth Description

BGK-C5-2 20°, 28°, 40° For use with the C5-2Q,


Supports: 14G-23G
BGK-L40UB 34°, 43°, 53°, 66° For use with the L17-7Q ,
Supports: 14G-23G
BGK-001 1.0cm, 1.5cm, 2.0cm For use with the L17-7Q ,
Supports: 21G
BGK-002 38°, 46°, 58° For use with the L12-5Q,
Supports: 14G-23G
BGK-003 1.0cm, 1.5cm, 2.0cm For use with the L12-5Q,
Supports: 21G
BGK-CR10UA 2° For use with the E8-4Q,
Supports: 16G, 18G
BGK-008 12°, 22° For use with the P5-1Q,
Supports: 14G-23G

09.
Acclarix AX2 series Diagnostic Ultrasound System

Measurements Application Measurements/calculations


Abdomen
• Default measurement unit options
- Distance: mm, or cm B-mode:
- Area: mm2, or cm2
- Volume: mm3, or cm3 • Liver
• Caliper Size: switch automatically according to - Length, Width, Height
the distance (3 sizes) - Volume (calculation)
• Dynamic display of measurement results - Portal Vein Diameter
• Reposition caliper - Common Hepatic Duct

General Measurements • Gallbladder


- Length, Height
B-mode - Gallbladder Wall Thickness
- Common Bile Duct
• Distance
• Circumference/Area (Ellipse, Trace) • Pancreas
• Angle - Head, Body, Tail, Duct
• Volume
• Stenosis • Spleen
- %Dist Stenosis (Distance) - Length, Height
- %Area Stenosis (Ellipse, Trace)
• Renal
M-mode - Length, Width, Height
- Volume (calculation)
• Caliper - Renal Cortex Thickness
- Distance
- Time • Aorta Diameter
- Slope
• HR PW mode:

Doppler mode • Abdominal Aorta


• Superior Mesenteric Artery
• Caliper: V1, V2, Acceleration, Time, RI, S/D, ΔV, • Inferior Mesenteric Artery
PG1, PG2, PHT • Hepatic Artery
• Trace: PS, ED, MD, RI, PI, S/D, Time, TAMax, VTI, • Splenic Artery
AT, DT, PGmax, PGmean • Renal Artery
• Auto Trace: PS, ED, MD, RI, PI, S/D, HR, Time, • Portal Vein
TAMax, TAMean, VTI, AT, DT, PGmax, PGmean • Inferior Vena Cava
• HR: HR • Main Portal Vein
• RI: PS, ED, RI, S/D • Hepatic Vein
• TEI: (only available for Cardiac preset) • Middle Hepatic Vein
• dp/dt: (only available for Cardiac preset) • Splenic Vein
• Superior Mesenteric Vein
• Inferior Mesenteric Vein

10.
Acclarix AX2 series Diagnostic Ultrasound System

Gynecology • Fetal Echo


B-mode: RV Diam, RA Diam, RVOT Diam, LV
B-mode: Diam, LA Diam, LVOT Diam, Ao Asc, Ao Arch Diam,
Ao Isthmus, Desc Aorta, MPA Diam, Ductus A, CTAR
• Uterus PW mode: FHR, MCA, Umb. Artery, Planenta
- Length, Width, Height Artery, Ductus Venosus, MV, TV, MPV, Ovary Artery,
- Endometrium Thickness Uterine Artery, Fetal Aorta, Desc Aorta, Ductus A
- UT Cavity
- UT-L/CX-L(calculation) • Gestational Age
• Fetal Growth
• Cervix • Estimated Fetal Weight (EFW)
- Length, Width, Height • Multi-gestational Measurement
- UT-L/CX-L(calculation)
Cardiac
• Ovary
- Length, Width, Height B-mode
• LV Simpson: A4C Dias., A4C Sys., A2C Dias.,
• Follicle A2C Sys., SV, EF, CO, SI, CI
- D1, D2, D3 • Vent. Dim: RVAWd, RVIDd, IVSTd, LVIDd, LVPWd,
- Follicle-Mean IVSTs, LVIDs, LVPWs
(Calculations: SV, EF, FS, CO, SI, CI)
• Cyst • Ao Asc
- D1, D2, D3 • RVOT Diam
• LVOT Diam
• Fluid POD • HR
• PV Diam
PW mode: • RVDs
• RA: Length, Width
• Uterine Artery • LA: Length, Width
• Ovary Artery • AoD

Obstetrics M-mode
• Vent. Dim
• Early OB • LVET
B-mode: GS, YS, CRL, NT, BPD, FL, HUM, AF. • MV: E-F Slope, EPSS
M-mode: FHR • LA/AO: LA, AoD, PVOT Diam
PW mode: Ductus Venosus, Ovary Artery,
Uterine Artery PW mode
• MV: E/A, MV PHT, MV Trace, IVRT, MV, A Dur,
• OB MV DecT
B-mode: NF, BPD, OFD, HC, AC, FL, TAD, APAD, • TV: TV trace, TV Max
CER, HUM, ULNA, RAD, TIB, FIB, APTD, TTD, • AoV: LVOT Trace, LVOT Vmax, AoV Trace, AoVVmax
FTA, THD, Foot, AF, AFI. • PV: PV trace, PV Max
M-mode: FHR • Pulmonic Vein: PVein S Vel, PVein D Vel, PV A Vel
PW mode: MCA, Umbilical Artery, Placenta
Artery, Ductus Venosus, FHR

11.
Acclarix AX2 series Diagnostic Ultrasound System

Urology Vascular

B-mode: B-mode:

• Renal • Carotid
- Length, Width, Height - Common Carotid Artery Intima-Media Thickness,
- Renal Cortex Thickness Internal Carotid Artery Intima-Media Thickness,
Carotid Artery Bifurcation Intima-Media
• Bladder Thickness
- Pre-void Bladder
(Length, Width, Height, Volume) PW-mode:
- Post-void Bladder
(Length, Width, Height, Volume) - Common Carotid Artery, External Carotid Artery,
Internal Carotid Artery, Vert Artery, Subclavian
• Prostate Artery, HR
- Length, Width, Height
PW-mode:
• Seminal
- Length, Width, Height • Upper Extremity Artery
- Subclavian Artery, Axillary Artery, Brachial Artery,
• Testis Ulnar Artery, Radial Artery, HR
- Length, Width, Height
PW-mode:
PW mode:
• Upper Extremity Vein
• Renal Artery - Subclavian Vein, Axillary Vein, Brachial Vein,
• Arcuate Artery Cephalic Vein, Basilic Vein, Ulnar Vein, Radial
• Segmental Artery Vein, Median Cubital Vein
• Interlobar Artery
PW-mode:
Small Parts
• Lower Extremity Artery
B-mode: - Common Femoral Artery, Deep Femoral Artery,
Superficial Femoral Artery, Common Lliac
• Thyroid Artery, External Llic Artery, Internal Lliac Artery,
- Length, Width, Height Popliteal Artery, Peroneal Artery, Posterior Tibial
- Thyroid Isthmus Artery, Anterior Tibial Artery, Dorsalis Pedis Artery,
HR
• Breast
- Lesion1, Lesion2, Lesion3, Lesion4, Lesion5 PW-mode:

• Testis • Lower Extremity Vein


- Length, Width, Height - Common Femoral Vein, Deep Femoral Vein,
Superficial Femoral Vein, Common Lliac Vein,
PW mode: External Lliac Vein, Internal Lliac Vein, Great
Saphenous Vein, Popliteal Vein, Peroneal Vein,
• Superior Thyroid Artery Posterior Tibial Vein, Anterior Tibial Vein, Small
• Inferior Thyroid Artery Saphenous Vein

12.
Acclarix AX2 series Diagnostic Ultrasound System

PW-mode: Exam Archiving

• Cephalic All clips and Static images stored on the system


- Anterior Cerebral Artery, Middle Cerebral are stored internally in Raw Data format. They can
Artery, Posterior Cerebral Artery, Anterior be archived to other storage device for long-term
Communicating Artery, Posterior storage as described below.
Communicating Artery, Basilar Artery,
Vertebral Artery, Internal Carotid Artery - Archived to DICOM server in DICOM format.
(Archiving Clip to DICOM server is not available
B-mode: currently)
- Archived to USB device in either DICOM, Raw
• Volume Flow Data or .bmp format.
- Volume Flow Area
Connectivity
PW mode:
Network:
- TAMean, Volume Flow (Calcu.)
• Wired network connection
Image Storage & Exam Archiving • Wi-Fi connection

Image Storage: DICOM 3.0 Service

• Static image/Cine clip is stored in local disk in • DICOM Storage


RawData format. - Connectivity to DICOM server for storage of all
• Two dedicated hard keys on the console for static image with patient information.
capturing static image and cine clips respectively. - Manual-Transfer in background on demand.
• Cine clips supports prospective and retrospective - Transfer management UI for viewing transfer
storing. task status.
• The length of cine clip is configurable.
• Prospective storing: max. 2 min length of clip • DICOM Modality Worklist
can be stored in real-time scanning. - Enables query of the patient worklist schedule
• Retrospective storing: all the clip data in the cine from hospital information system to the
buffer can be stored in cine review mode, ultrasound system via DICOM network connection
max. 6 min (tender). - Query of worklist on demand or on start of exam.
• Supports up to 30,000 lossless single frames - Populates with Patient Information screen with
• Supports cine clips of: patient demographic information automatically
- Up to 200,000 frames for B mode when one patient is selected.
- Up to 35,000 frames for Color mode
- Up to 180s for M
- Up to 240s for PW/CW mode

Exam Database

• Support exam storage without patient info.


• Support exam query
• Support review current exam or prior exam
• Support review images of an exam
• Support export images as BMP, Raw Data or
DICOM format
• Support export cine clip as Raw Data format
• Support export exams (including patient info.
and images)

13.
Acclarix AX2 series Diagnostic Ultrasound System

Supported Peripherals Safety and Regulatory

Printers: The Acclarix AX2 series Diagnostic Ultrasound


System have been designed, manufactured and
• Video printers tested to comply with the following internationally
- SONY UP-X898MD recognized standards:
- SONY UP-D25MD
- SONY UP-25MD - IEC 60601-1: Medical Equipment Safety
- IEC 60601-1-2: Medical Device Electromagnetic
• Graph/text printer Safety
- HP OfficeJet Pro 251dw - IEC 60601-2-37: Ultrasonic Medical Equipment
- HP LaserJet Pro 200 M251n Safety
- HP LaserJet CP1525n Color - IEC 62133: Battery Safety
- HP DeskJet Ink Advantage 2010 - IEC 62304: Medical Device Software Life-cycle
- HP DeskJet 1010 Color Process
- HP DeskJet 1510 Color - IEC 62366: Medical Device Usability Engineering
- HP DeskJet Pro 400 - EN ISO 14971: Medical Device Risk Management
- HP DeskJet Pro M401d - ISO 10993: Medical Device Biocompatibility
- Canon PIXMA E518 - NEMA UD2: Acoustic Output Measurement
- Canon iP2780 Standard for Diagnostic Ultrasound Equipment
- HP DeskJet 2029
- HP DeskJet 1112
- EPSON L310
- HP DeskJet 1050
- HP DeskJet 2050
- HP DeskJet M252n
- EPSON L130

14.

You might also like