D Meter Configuration Report For MR-1811C113-02

The document provides configuration details for an Ethernet device including metering ratios, communication settings, energy pulsing settings, and digital input configurations.

Uploaded by

Carolina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views14 pages

D Meter Configuration Report For MR-1811C113-02

The document provides configuration details for an Ethernet device including metering ratios, communication settings, energy pulsing settings, and digital input configurations.

Uploaded by

Carolina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

Meter Configuration Report for EthernetDevice

Report printed on martes, 04 de febrero de 2020 19:00:00


Report generated by Luis Aedo

Parameter Value
Basic Setup - PT/CT Ratios
PM1 Volts Mode 4W-WYE
PM1 PT Prim 7200.0
PM1 PT Sec 240.0
PM1 CT Prim 200.0
PM1 CT Sec 5.0
PM1 I4 CT Prim 5.0
PM1 I4 CT Sec 5.0
Scale Rev Param ON
PM1 PhaseOrder ABC
Nominal Voltage 8660.0
Nominal Current 5.0
Nominal Frequency 50Hz

Basic Setup - Nameplate Info


FAC1 DeviceType 7400
FAC1 Revision 001.004.003
FAC1 Feature Set Standard
FAC1 SerialNum MR-1811C113-02
FAC1 Template 7400_FAC-PQ_V1.4.0.0.1
FAC1 Options
FAC1 Owner ENERSIDE
FAC1 Tag1 MALLOA
FAC1 Tag2 PMGD DN MARIANO

Basic Setup - Rollover


Energy Rollover 10000000
I^2h/V^2h Rollover 1000000000

Basic Setup - Localization


DOP1 Language English
DOP1 Digit Grouping 1000.0
DOP1 Date Format MM/DD/YYYY
DOP1 Time Format 24 H
PM1 PF Sign Convention IEEE
DOP1 Measurement Symbols IEEE
PM1 Phase Lbls ABC

Security - Security
Security Mode Standard
Hardware Lock Disabled
Front Panel Password Yes
Active Web Server Yes
Allow Web Server Programming Yes
Secure Web Page Viewing No
Allow Modbus Programming No
Allow Front Panel Programming Yes
Allow Broadcasting Time Synchronization Yes
Telnet Lock Attempts 8
FTP Lock Attempts 8
Factory Lock Attempts 8
Front Panel Lock Attempts 8
ION Lock Attempts 8
HTTP Lock Attempts 8
Lockout Duration Minutes 1440
ION Silence Minutes 30
HTTP Silence Minutes N/A
Valid Auth Priority 0
Invalid Auth Priority 128
Lockout Auth Priority 255

Serial Settings - Com1


CM1 Protocol ION
CM1 Unit ID 1
CM1 Baud Rate 19200
CM1 Rx Timeout 3.0
CM1 Serial Port 8N1
CM1 RS485 Bias OFF

Serial Settings - Com2


CM2 Protocol ION
CM2 Unit ID 101
CM2 Baud Rate 19200
CM2 Rx Timeout 3.0
CM2 Serial Port 8N1

Serial Settings - Com3


CM3 Protocol ION
CM3 Unit ID 102
CM3 Rx Timeout 3.0

Basic Ethernet - IPv4


IP Method Stored
IPv4 Address 192.168.5.203
Subnet Mask 255.255.255.0
Gateway 192.168.5.1

Basic Ethernet - IPv6


IPv6 Enabled Yes
IPv6 Link Local fe80::260:78ff:fe0a:7709
IP Method Stored
Global IPv6 Address ::
Global Gateway ::
Basic Ethernet - TCP/IP
Ethernet Device Name ION7400_0a7709
ETH1 Rx Timeout 3.0
Modbus TCP Timeout 0
Modbus Gateway Disabled
MAC Address 00-60-78-0A-77-09

Advanced Ethernet - DNS


ETH1 Primary DNS None
ETH1 Secondary DNS None

Advanced Ethernet - SMTP


ETH1 SMTP Server None
ETH1 SMTP Connection Timeout 3 minutes

Advanced Ethernet - NTP


CL1 Enable NTP Time Sync No
CL1 NTP Time Sync Interval 10 minutes
CL1 NTP Event Logging Threshold 0.02
ETH1 NTP Server None
CL1 Time Sync Type UTC
CL1 Time Sync Source ETHERNET
Time Sync Count 0
Time Since Sync/Reset "Not Available"

Advanced Ethernet - SNMP


ETH1 Enable SNMP No
SMO1 Enable Traps Disabled
SMO1 Trap Rcvr1 Addr None
SMO1 Trap Rcvr2 Addr None
SMO1 Trap Rcvr3 Addr None
SMO1 Trap Rcvr4 Addr None
SMO1 Read Only Community public
SMO1 Read Write Community private
SMO1 System Contact Contact
SMO1 System Name ION7400
SMO1 System Location Schneider

Advanced Ethernet - SysLog


EL1 Enable Syslog No
ETH1 Syslog Server None

Clock - Timezone
Timezone UTC(GMT+00:00)
CL1 Time Sync Type UTC
CL1 Time Sync Source ETHERNET
CL1 Clock Source Internal
CL1 DST Offset 0
CL1 LocalTime mar feb 04, 2020 18:54:32
Time Sync Count 0
Time Since Sync/Reset "Not Available"
Start of the week Monday

Demand - Rolling Block


Number of Sub-intervals 1
Sub-interval Length 15 minutes
Demand Lockout 25 days
Test Sub-intervals 1
Test Sub-interval Length 15 minutes

LED Pulsing - Top LED


Source kW tot
Enable CAP Enable
CAP1 Int Mode Absolute
W Kt 1.8
W Pulse Width 0.05
Pulser Mode Always
Wh pulse ovrld Pulsing normally

LED Pulsing - WATT LED


Source kW del+rec
Enable CAP Enable
CAP2 Int Mode Absolute
W Kt 1.8
W Pulse Width 0.05
Pulser Mode Always
Wh pulse ovrld Pulsing normally

Energy Pulsing - Wh Del


CAP4 Kt 1.8
CAP4 Pulse Width 0.1
CAP4 OutputMode Pulse
CAP4 Port Not Used
Wh del ovrld "Not Available"

Energy Pulsing - Wh Rec


CAP5 Kt 1.8
CAP5 Pulse Width 0.1
CAP5 OutputMode Pulse
CAP5 Port Not Used
Wh rec ovrld "Not Available"

Energy Pulsing - VARh Del


CAP6 Kt 1.8
CAP6 Pulse Width 0.1
CAP6 OutputMode Pulse
CAP6 Port Not Used
VARh del ovrld "Not Available"

Energy Pulsing - VARh Rec


VAR Kt 1.8
VAR Pulse Width 0.05
CAP7 OutputMode Pulse
CAP7 Port VAR LED
VARh rec ovrld "Not Available"

Energy Pulsing - End of Interval


PU1 PulseWidth 0.1
PU1 OutputMode Pulse
PU1 Port Not Used

Energy Applications - Digital Input Based


Conditional Energy Disabled
Input Metering CH 1 Disabled
Standard quantity Yes
Pulse Weight 1
Units No units
Demand Period 15 minutes
Rate No units
Source ID
Input Metering CH 2 Disabled
Standard quantity Yes
Pulse Weight 1
Units No units
Demand Period 15 minutes
Rate No units
Source ID
Input Metering CH 3 Disabled
Standard quantity Yes
Pulse Weight 1
Units No units
Demand Period 15 minutes
Rate No units
Source ID
Input Metering CH 4 Disabled
Standard quantity Yes
Pulse Weight 1
Units No units
Demand Period 15 minutes
Rate No units
Source ID
Input Metering CH 5 Disabled
Standard quantity Yes
Pulse Weight 1
Units No units
Demand Period 15 minutes
Rate No units
Source ID

Energy Applications - Incremental Energy


Status Disabled

Digital Inputs - S1
Input Mode Pulse
Polarity Non-Inverting
Debounce 0.001
Assigned Port Port S1
EventLog Mode Log Off
S1 State OFF

Digital Inputs - S2
Input Mode Pulse
Polarity Non-Inverting
Debounce 0.001
Assigned Port Port S2
EventLog Mode Log Off
S2 State OFF

Digital Inputs - S3
Input Mode Pulse
Polarity Non-Inverting
Debounce 0.001
Assigned Port Port S3
EventLog Mode Log Off
S3 State OFF

Digital Outputs - D1
Source NotUsed
Force ON NotUsed
Force OFF NotUsed
Normal NotUsed
Polarity Non-Inverting
PulseWidth 0.0
Assigned Port Not Used
D1 State "Not Available"

Option I/O Modules - Module A


Card Type None
Card Status None

Option I/O Modules - Module B


Card Type None
Card Status None

Option I/O Modules - Module C


Card Type None
Card Status None

Option I/O Modules - Module D


Card Type None
Card Status None

Memory - Status
Log Memory 10240 kB
In Use 44.1%
Available 55.9%
Load Profile
Allocated 5.92%
Duration 95.0 days
Records 9120
Event Log
Allocated 0.13%
Duration N/A
Records 500
Sag/Swell Waveforms
Allocated 16.35%
Duration N/A
Records 30
Sag/Swell COMTRADE
Allocated 0.01%
Duration N/A
Records 10
EgyDmd Log
Allocated 2.50%
Duration 40.0 days
Records 3840
Harm high Log
Allocated 0.43%
Duration 35.0 days
Records 840
Harm mean Log
Allocated 0.43%
Duration 35.0 days
Records 840
Hist high Log
Allocated 2.82%
Duration 35.0 days
Records 3360
Hist low Log
Allocated 2.82%
Duration 35.0 days
Records 3360
Hist mean Log
Allocated 2.82%
Duration 35.0 days
Records 3360
Loss Log
Allocated 1.70%
Duration 35.0 days
Records 3360
Sag/Swell Log
Allocated 0.09%
Duration N/A
Records 100
DailyNom Log
Allocated 0.08%
Duration N/A
Records 450
EN50160 Logs
Allocated 3.64%
Duration N/A
Records N/A
IEC 4-30 Logs
Allocated 3.02%
Duration N/A
Records N/A
System Resources
Allocated 0.00%
Duration N/A
Records N/A

Revenue Log - Channels


Source 1 kWh del int
Source 2 kVARh del int
Source 3 kWh rec int
Source 4 kVARh rec int
Source 5 Vll ab mean
Source 6 Vll bc mean
Source 7 Vll ca mean
Source 8 I a mean
Source 9 I b mean
Source 10 I c mean
Source 11 Vll avg mean
Source 12 I avg mean
Source 13 NotUsed
Source 14 NotUsed
Source 15 NotUsed
Source 16 NotUsed
Enable NotUsed
Record Revnue Log Trg
Rearm NotUsed

Revenue Log - Interval/Depth


Interval length 15 minutes
RE1 Depth 9120
RE1 Insert Outage Records Yes - Zero Fill Disabled

EnergyDemand Log - Channels


Source 1 kWh del
Source 2 kWh rec
Source 3 kWh del-rec
Source 4 kVARh del
Source 5 kVARh rec
Source 6 kVARh del-rec
Source 7 kVAh del+rec
Source 8 kW sd del-rec
Source 9 kVAR sd del-rec
Source 10 kVA sd del+rec
Source 11 PF lag mean
Source 12 PF lead mean
Source 13 NotUsed
Source 14 NotUsed
Source 15 NotUsed
Source 16 NotUsed
Enable EgyDmd Log Enbl
Record EgyDmd Log Trg
Rearm NotUsed

EnergyDemand Log - Interval/Depth


PT6 Period 15 minutes
RE10 Depth 3840

PT/CT Correction - ITC Correction


Active Correction None

Transformer Loss - Method Selection


Loss Comp Enble Comp Disabled
Comp Mthod Slct Method 1

Transformer Loss - Test Sheet


MP Definition 1 Load-side
MP Definition 2 Not Xfrmer-side
kVA rated 0
Vll rated 0
LWFe test 0
LWCu test 0
% Excitation 0
% Impedance 0
PT Ratio 1
CT Ratio 1
Xformer ratio 1
Line Length-SY 0
r/l - SY 0
x/l - SY 0
Line Length-LD 0
r/l - LD 0
x/l - LD 0

Transformer Loss - %Loss Constants


Rated Mtr Volts 120
1/2 Mtr Current 5
# Stator Elmnts 3
PT Ratio 1
CT Ratio 1
Cu Comp Enable ON
%LWCu 0
%LVCu 0
Fe Comp Enable ON
%LWFe 0
%LVFe 0

Time of Use - Time of Use


Sample TOU
TOU1 Season 1 Oct 1 - May 31
TOU1 Season 1 Weekday Rates A 0:00
TOU1 Season 1 Weekend Rates A 0:00
TOU1 Season 1 Alt 1 Rates
TOU1 Season 1 Alt 2 Rates
TOU1 Season 1 Holiday Rates A 0:00
TOU1 Season 2 Jun 1 - Sep 30
TOU1 Season 2 Weekday Rates A 0:00, B 10:00, A 18:00
TOU1 Season 2 Weekend Rates A 0:00
TOU1 Season 2 Alt 1 Rates
TOU1 Season 2 Alt 2 Rates
TOU1 Season 2 Holiday Rates A 0:00
TOU1 Season 3
TOU1 Season 3 Weekday Rates
TOU1 Season 3 Weekend Rates
TOU1 Season 3 Alt 2 Rates
TOU1 Season 3 Holiday Rates
TOU1 Season 4
TOU1 Season 4 Weekday Rates
TOU1 Season 4 Weekend Rates
TOU1 Season 4 Alt 1 Rates
TOU1 Season 4 Alt 2 Rates
TOU1 Season 4 Holiday Rates
TOU1 Weekdays Mon - Fri
TOU1 Weekends Sat, Sun
TOU1 Alt 1 Days
TOU1 Alt 2 Days
TOU1 Holidays Jan 1, Jun 14, Jul 4, Dec 25, Feb 21 2000, May 29 2000, Sep 4
2000, Nov 23 2000
TOU1 Self Read Dates Jan 1, Apr 1, Jul 1, Oct 1

Alarming - Standard

Over kW sd
High Limit Not set
Low Limit Not set
Priority Medium
Over I a
High Limit Not set
Low Limit Not set
Priority Medium

Over I b
High Limit Not set
Low Limit Not set
Priority Medium

Over I c
High Limit Not set
Low Limit Not set
Priority Medium

Over I 4
High Limit Not set
Low Limit Not set
Priority Medium

Over V unbal
High Limit 5
Low Limit 5
Priority Medium

Over I unbal
High Limit 10
Low Limit 10
Priority Medium

Over THD V1
High Limit 5
Low Limit 5
Priority Medium

Over THD V2
High Limit 5
Low Limit 5
Priority Medium

Over THD V3
High Limit 5
Low Limit 5
Priority Medium

Freq Setpoint
High Limit 5.0
Low Limit 5.0
Priority Medium*
V1 Setpoint
High Limit 5.0
Low Limit 5.0
Priority Medium*

V2 Setpoint
High Limit 5.0
Low Limit 5.0
Priority Medium*

V3 Setpoint
High Limit 5.0
Low Limit 5.0
Priority Medium*

Alarming - Sag/Swell

Voltage
Swell Limit 110%
Sag Limit 90%
Hysteresis 2%
Priority High (200)

Current Swell
Pickup 155%
Dropout 145%
Priority High (200)

Current Sag
Pickup 45%
Dropout 55%
Priority High (200)

Alarming - Digital Input

Port S1
Active when Port S1 ON
Priority Info Only

Port S2
Active when Port S2 ON
Priority Info Only

Port S3
Active when Port S3 ON
Priority Info Only

Power Quality - Sag/Swell Logging


Sag/Swell depth 100
Waveform depth 30
Waveform format 32x54
Post Event Cycles 7
COMTRADE Status Enabled
COMTRADE Depth 10

Power Quality - Advanced PQ


EN50160 Enable OFF
4-30 Enable ON

Displays - Front Panel


kWh
Line 1 kWh del
Line 2 kWh rec
DIS1 Screen Title Active Energy
DIS1 Screen Resolution Default
DIS1 Last Digit Mode Round
DIS1 Screen Number Normal Screen 1
kVARh
Line 1 kVARh del
Line 2 kVARh rec
DIS2 Screen Title Reactive Energy
DIS2 Screen Resolution Default
DIS2 Last Digit Mode Round
DIS2 Screen Number Normal Screen 2
kVAh
Line 1 kVAh del
Line 2 kVAh rec
DIS3 Screen Title Apparent Energy
DIS3 Screen Resolution Default
DIS3 Last Digit Mode Round
DIS3 Screen Number Normal Screen 3
Peak Demand Del
Line 1 kW sd mx del
Line 2 kVAR sd mx del
Line 3 kVA sd mx del
DIS4 Screen Title Peak Demand Delivered
DIS4 Screen Resolution Default
DIS4 Last Digit Mode Round
DIS4 Screen Number Normal Screen 4
Pk Dmd Rst Cnt
Line 1 Pk Dmd Rset Cnt
DIS5 Screen Title Peak Demand Reset Count
DIS5 Screen Resolution Default
DIS5 Last Digit Mode Round
DIS5 Screen Number Normal Screen 5
kWh Test
Line 1 kWh del T
Line 2 kWh rec T
Line 3 kWh del+rec T
DIS6 Screen Title Active Energy Test
DIS6 Screen Resolution Default
DIS6 Last Digit Mode Round
DIS6 Screen Number Test Screen 1
kVARh Test
Line 1 kVARh del T
Line 2 kVARh rec T
Line 3 kVARh del+rec T
DIS7 Screen Title Reactive Energy Test
DIS7 Screen Resolution Default
DIS7 Last Digit Mode Round
DIS7 Screen Number Test Screen 2
kW Block Test
Line 1 kW sd del T
Line 2 kW sd rec T
Line 3 kW sd mx del T
Line 4 kW sd mx rec T
DIS8 Screen Title Demand Test
DIS8 Screen Resolution Default
DIS8 Last Digit Mode Round
DIS8 Screen Number Test Screen 3