FCC Test Report: ("X" Can Be 0-9, A-Z or Blank For Marketing Purpose)
FCC Test Report: ("X" Can Be 0-9, A-Z or Blank For Marketing Purpose)
Address: 12F., No. 111, Zhongcheng Rd., Tucheng Dist., New Taipei City 23674
Taiwan (R.O.C.)
Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
(R.O.C.)
FCC Registration/
Designation Number: 418586 / TW1078
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal government.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Product: ARS-2000
Brand: Vecow
The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.
Product ARS-2000
Brand Vecow
Test Model ARS-2000 Series
ARS-2XXXXXXXXXXXXXXX
Series Model
(“X” can be 0-9, A-Z or blank for marketing purpose)
Model Difference For marketing purpose
Sample Status Engineering sample
Operating Software Windows 10, Windows 8.1, Windows 7, Linux
Power Supply Rating 6V to 36V, DC-in
Accessory Device Adapter
Data Cable Supplied N/A
Note:
1. The EUT is an Embedded Box PC with the following interfaces.
DC input
USB 3.0*4
LAN (10/100/1000Mbps)
POE LAN*2
DVI-D (resolution Up to 1920 x 1200 @ 60Hz)
DVI-I (resolution Up to 1920 x 1200 @ 60Hz)
Mic. in
Line out
Isolated DIO*2 (32 Isolated DIO : 16 DI, 16 DO)
CFast socket
COM*4 (RS-232/ 422/ 485)
2. The EUT was configured with the following key components:
3.3 Operating Modes of EUT and Determination of Worst Case Operating Mode
1. Test modes are presented in the report as below.
Mode Test Condition Input Power
Conducted emission test
1 Full system, DVI & D-Sub: 1920x1080, 60Hz 120Vac/ 60Hz (Adapter)
Radiated emission test
1 Full system, DVI & D-Sub: 1920x1080, 60Hz 120Vac/ 60Hz (Adapter)
The highest frequency generated or used within the EUT or on which the EUT operates or tunes is 4000 MHz,
provided by Vecow Co., Ltd., for detailed internal source, please refer to the manufacturer's specifications.
TEST CONFIGURATION
9
1 Isolated DIO*2
LCD Monitor (A) DVI-D
3
1 USB 3.0 USB 3.0 HDD (C)
LCD Monitor (A) DVI-I
EUT
7 2
Microphone (I) Audio In USB 3.0 USB Printer (B)
4
6 Audio Out USB 3.0 USB Mouse (D)
Earphone (H)
5
10 USB 3.0 USB Keyboard (E)
AC Adapter (EUT) DC input
11
12
LAN
120Vac
13
Remote site
Notebook PC (K)
Shielding
ID Descriptions Qty. Length (m) Cores (Qty.) Remarks
(Yes/No)
1. DVI cable 2 1.8 Y 2 Provided by Lab
2. USB cable 1 1.5 Y 0 Provided by Lab
3. USB cable 1 0.5 Y 0 Provided by Lab
4. USB cable 1 1.8 Y 1 Provided by Lab
5. USB cable 1 1.5 Y 0 Provided by Lab
6. Audio cable 1 1.2 N 0 Provided by Lab
7. Audio cable 1 2.4 N 0 Provided by Lab
8. LAN cable (Cat. 5e) 2 3.0 N 0 Provided by Lab
9. cable 2 0.5 N 0 Supplied by client
10. DC cable 1 1.15 N 1 Supplied by client
11. AC power cord 1 1.8 N 0 Provided by Lab
12. GND cable 1 1.2 N 0 Provided by Lab
13. LAN cable (Cat. 5e) 1 10 N 0 Provided by Lab
Note: The core(s) is(are) originally attached to the cable(s).
Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
ROHDE & SCHWARZ
ESCS 30 838251/021 Nov. 1, 2017 Oct. 31, 2018
TEST RECEIVER
ROHDE & SCHWARZ
ENV216 101195 May 2, 2017 May 1, 2018
Artificial Mains Network (For EUT)
LISN With Adapter (for EUT) AD10 C03Ada-002 May 2, 2017 May 1, 2018
EMCO L.I.S.N. (For peripherals) 3825/2 9504-2359 Jul. 25, 2017 Jul. 24, 2018
SCHWARZBECK
NNLK8129 8129229 May 9, 2017 May 8, 2018
Artificial Mains Network (For EUT)
Software Cond_V7.3.7.4 NA NA NA
RF cable (JYEBAO) With10dB PAD 5D-FB Cable-C03-01 Sep. 19, 2017 Sep. 18, 2018
LYNICS Terminator (For EMCO LISN) 0900510 E1-01-300 Jan. 18, 2017 Jan. 17, 2018
LYNICS Terminator (For EMCO LISN) 0900510 E1-01-301 Jan. 18, 2017 Jan. 17, 2018
ROHDE & SCHWARZ
ESH3-Z5 100220 Nov. 14, 2017 Nov. 13, 2018
Artificial Mains Network (For TV EUT)
LISN With Adapter (for TV EUT) 100220 N/A Nov. 14, 2017 Nov. 13, 2018
Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.
2. The test was performed in Shielded Room No. 3.
3. The VCCI Site Registration No. C-10274.
4. Tested Date: Dec. 11, 2017
V e r t ic a l G r o u n d
R e f e r e n c e P la n e T e s t R e c e iv e r
EUT
4 0cm
80 cm
L IS N
H o r iz o n ta l G r o u n d
R e fe r e n c e P la n e
N o te : S u p p o r t u n its w e r e c o n n e c t e d to s e c o n d L IS N .
For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.
Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
ROHDE & SCHWARZ
ESCI 100412 Sep. 1, 2017 Aug. 31, 2018
TEST RECEIVER
Schwarzbeck
VULB9168 9168-479 Dec. 16, 2016 Dec. 15, 2017
BILOG Antenna
Agilent Preamplifier 8447D 2944A08312 Feb. 21, 2017 Feb. 20, 2018
CT Turn Table TT100 CT-0055 NA NA
CT Tower AT100 CT-0055 NA NA
Software Radiated_V7.6.15.9.5 NA NA NA
ADT RF Switches BOX EM-H-01-1 1002 Sep. 21 2017 Sep. 20, 2018
WOKEN RF cable
8D CABLE-ST6-01 Sep. 21 2017 Sep. 20, 2018
With 5dB PAD
Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
to NML/ROC and NIST/USA.
2. The test was performed in Open Site No. 6.
3. The VCCI Site Registration No. R-728.
4. Tested Date: Dec. 8, 2017
Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
quasi-peak detection (QP) at frequency up to 1GHz.
Ant. Tower
1- 4m
Variable
10m
EUT&
Support Units
Turn Table
80cm
Ground Plane
Test Receiver
For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.
Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
Agilent Spectrum E4446A MY51100009 Jun. 1, 2017 May 31, 2018
Agilent Test Receiver N9038A MY51210137 Jun. 23, 2017 Jun. 22, 2018
Agilent Preamplifier 8449B 3008A01292 Feb. 22, 2017 Feb. 21, 2018
MITEQ Preamplifier AMF-6F-260400-33-8P 892164 Feb. 21, 2017 Feb. 20, 2018
EMCI Preamplifier EMC184045B 980235 Feb. 22, 2017 Feb. 21, 2018
Schwarzbeck Horn Antenna BBHA-9170 212 Dec. 30, 2016 Dec. 29, 2017
EMCO Horn Antenna 3115 6714 Dec. 29, 2016 Dec. 28, 2017
Max Full. Turn Table MF7802 MF780208216 NA NA
Software Radiated_V8.7.08 NA NA NA
SUHNER RF cable
SF102 Cable-CH10-3.6m Aug. 14, 2017 Aug. 13, 2018
With 3/4dB PAD
MICRO-TRONICS
BRC50703-01 010 May 31, 2017 May 30, 2018
Notch filter
MICRO-TRONICS
BRM17690 005 May 31, 2017 May 30, 2018
Band Pass Filter
Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
to NML/ROC and NIST/USA.
2. The test was performed in Chamber No. 10.
3. The Industry Canada Reference No. IC 7450E-11.
4. The VCCI Site Registration No. G-10427
5. Tested Date: Dec. 11, 2017
Note: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video bandwidth is 3MHz for
Peak detection (PK) at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz.
Ant. Tower
1-4m*
Variable
EUT & 3m
Support Units
Turn Table
Absorber
80cm
Ground Plane
Spectrum analyzer
* : depends on the EUT height and the antenna 3dB beamwidth both.
For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and
approved according to ISO/IEC 17025.
If you have any comments, please feel free to contact us at the following:
Email: [email protected]
Web Site: www.bureauveritas-adt.com
The address and road map of all our labs can be found in our web site also.