0% found this document useful (0 votes)
36 views27 pages

FCC Test Report: ("X" Can Be 0-9, A-Z or Blank For Marketing Purpose)

The document reports the results of electromagnetic compatibility testing on a Vecow ARS-2000 Series product according to FCC, ICES, and ANSI standards. The tests included conducted emissions at mains ports, radiated emissions up to 1 GHz, and radiated emissions above 1 GHz. The product was found to comply with all requirements.

Uploaded by

lemosro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views27 pages

FCC Test Report: ("X" Can Be 0-9, A-Z or Blank For Marketing Purpose)

The document reports the results of electromagnetic compatibility testing on a Vecow ARS-2000 Series product according to FCC, ICES, and ANSI standards. The tests included conducted emissions at mains ports, radiated emissions up to 1 GHz, and radiated emissions above 1 GHz. The product was found to comply with all requirements.

Uploaded by

lemosro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 27

FCC Test Report

Report No.: FD171206D25

Test Model: ARS-2000 Series

Series Model: ARS-2XXXXXXXXXXXXXXX


(“X” can be 0-9, A-Z or blank for marketing purpose)
Received Date: Dec. 6, 2017

Test Date: Dec. 8 ~ 11, 2017

Issued Date: Jan. 9, 2018

Applicant: Vecow Co., Ltd.

Address: 12F., No. 111, Zhongcheng Rd., Tucheng Dist., New Taipei City 23674
Taiwan (R.O.C.)

Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
(R.O.C.)
FCC Registration/
Designation Number: 418586 / TW1078

This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal government.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: FD171206D25 Page No. 1 / 27 Report Format Version: 6.1.2


Table of Contents
Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ......................................................................................................................... 4
2 Summary of Test Results......................................................................................................................... 5
2.1 Measurement Uncertainty ................................................................................................................... 5
2.2 Modification Record ............................................................................................................................ 5
3 General Information ................................................................................................................................. 6
3.1 Features of EUT .................................................................................................................................. 6
3.2 General Description of EUT ................................................................................................................ 6
3.3 Operating Modes of EUT and Determination of Worst Case Operating Mode ................................... 7
3.4 Test Program Used and Operation Descriptions................................................................................. 7
3.5 Primary Clock Frequencies of Internal Source ................................................................................... 7
4 Configuration and Connections with EUT ............................................................................................. 8
4.1 Connection Diagram of EUT and Peripheral Devices ......................................................................... 8
4.2 Configuration of Peripheral Devices and Cable Connections ............................................................. 9
5 Conducted Emissions at Mains Ports .................................................................................................. 10
5.1 Limits ................................................................................................................................................. 10
5.2 Test Instruments ................................................................................................................................ 10
5.3 Test Arrangement ............................................................................................................................... 11
5.4 Test Results ....................................................................................................................................... 12
6 Radiated Emissions up to 1 GHz .......................................................................................................... 14
6.1 Limits ................................................................................................................................................. 14
6.2 Test Instruments ................................................................................................................................ 15
6.3 Test Arrangement .............................................................................................................................. 16
6.4 Test Results ....................................................................................................................................... 17
7 Radiated Emissions above 1 GHz......................................................................................................... 19
7.1 Limits ................................................................................................................................................. 19
7.2 Test Instruments ................................................................................................................................ 20
7.3 Test Arrangement .............................................................................................................................. 21
7.4 Test Results ....................................................................................................................................... 22
8 Pictures of Test Arrangements ............................................................................................................. 24
8.1 Conducted Emissions at Mains Ports ............................................................................................... 24
8.2 Radiated Emissions up to 1 GHz ...................................................................................................... 25
8.3 Radiated Emissions above 1 GHz .................................................................................................... 26
Appendix – Information on the Testing Laboratories ................................................................................ 27

Report No.: FD171206D25 Page No. 2 / 27 Report Format Version: 6.1.2


Release Control Record

Issue No. Description Date Issued


FD171206D25 Original release. Jan. 9, 2018

Report No.: FD171206D25 Page No. 3 / 27 Report Format Version: 6.1.2


1 Certificate of Conformity

Product: ARS-2000

Brand: Vecow

Test Model: ARS-2000 Series

Series Model: ARS-2XXXXXXXXXXXXXXX


(“X” can be 0-9, A-Z or blank for marketing purpose)
Sample Status: Engineering sample

Applicant: Vecow Co., Ltd.

Test Date: Dec. 8 ~ 11, 2017

Standards: 47 CFR FCC Part 15, Subpart B, Class A


ICES-003:2016 Issue 6, Class A
ANSI C63.4:2014

The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.

Prepared by : , Date: Jan. 9, 2018


Jessica Cheng / Senior Specialist

Approved by : , Date: Jan. 9, 2018


Henry Lai / Director

Report No.: FD171206D25 Page No. 4 / 27 Report Format Version: 6.1.2


2 Summary of Test Results

47 CFR FCC Part 15, Subpart B / ICES-003:2016 Issue 6, Class A


ANSI C63.4:2014
FCC ICES-003
Test Item Result/Remarks Verdict
Clause Clause
AC Power Line Conducted Minimum passing Class A margin
15.107 6.1 Pass
Emissions is -15.28 dB at 0.15781 MHz
Radiated Emissions up to 1 Minimum passing Class A margin
6.2.1 Pass
GHz is -0.53 dB at 999.99 MHz
15.109
Radiated Emissions above 1 Minimum passing Class A margin
6.2.2 Pass
GHz is -7.68 dB at 1233.23 MHz
Note: There is no deviation to the applied test methods and requirements covered by the scope of this report.

2.1 Measurement Uncertainty


Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
EUT:
The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note that
the uncertainty values are provided for informational purposes only and are not used in determining the
PASS/FAIL results.
Expanded Uncertainty
Measurement Frequency
(k=2) (±)
Conducted Emissions at mains ports 150kHz ~ 30MHz 2.77 dB
Radiated Emissions up to 1 GHz 30MHz ~ 1GHz 3.89 dB
Radiated Emissions above 1 GHz Above 1GHz 4.97 dB

2.2 Modification Record


There were no modifications required for compliance.

Report No.: FD171206D25 Page No. 5 / 27 Report Format Version: 6.1.2


3 General Information
3.1 Features of EUT
The tests reported herein were performed according to the method specified by Vecow Co., Ltd., for detailed
feature description, please refer to the manufacturer's specifications or user's manual.

3.2 General Description of EUT

Product ARS-2000
Brand Vecow
Test Model ARS-2000 Series
ARS-2XXXXXXXXXXXXXXX
Series Model
(“X” can be 0-9, A-Z or blank for marketing purpose)
Model Difference For marketing purpose
Sample Status Engineering sample
Operating Software Windows 10, Windows 8.1, Windows 7, Linux
Power Supply Rating 6V to 36V, DC-in
Accessory Device Adapter
Data Cable Supplied N/A
Note:
1. The EUT is an Embedded Box PC with the following interfaces.
 DC input
 USB 3.0*4
 LAN (10/100/1000Mbps)
 POE LAN*2
 DVI-D (resolution Up to 1920 x 1200 @ 60Hz)
 DVI-I (resolution Up to 1920 x 1200 @ 60Hz)
 Mic. in
 Line out
 Isolated DIO*2 (32 Isolated DIO : 16 DI, 16 DO)
 CFast socket
 COM*4 (RS-232/ 422/ 485)
2. The EUT was configured with the following key components:

Report No.: FD171206D25 Page No. 6 / 27 Report Format Version: 6.1.2


3. The EUT uses following adapter.
Brand MEAN WELL
Model GS160A24
Input Power 100-240Vac, 50/60Hz, 2.0A
Output Power 24V, 6.67A, 160W max.
Power Line Non-shielded DC (1.15m) with one ferrite core

3.3 Operating Modes of EUT and Determination of Worst Case Operating Mode
1. Test modes are presented in the report as below.
Mode Test Condition Input Power
Conducted emission test
1 Full system, DVI & D-Sub: 1920x1080, 60Hz 120Vac/ 60Hz (Adapter)
Radiated emission test
1 Full system, DVI & D-Sub: 1920x1080, 60Hz 120Vac/ 60Hz (Adapter)

3.4 Test Program Used and Operation Descriptions

a. Turned on the power of all equipment.


b. EUT ran a test program to enable all functions.
c. EUT read and wrote messages from/to card reader, SSD and ext. HDDs.
d. EUT sent and received messages to/from Notebook PC (kept in a remote area) via one UTP
LAN cable.
e. EUT sent “H” messages to ext. LCD Monitors. Then they displayed “H” patterns on their screens
simultaneously.
f. EUT sent 1kHz audio signal to earphone.
g. EUT sent messages to printer and printer printed them out.
h. Cameras captured video image to LCD Monitors via EUT.
i. Steps c-i were repeated.

3.5 Primary Clock Frequencies of Internal Source

The highest frequency generated or used within the EUT or on which the EUT operates or tunes is 4000 MHz,
provided by Vecow Co., Ltd., for detailed internal source, please refer to the manufacturer's specifications.

Report No.: FD171206D25 Page No. 7 / 27 Report Format Version: 6.1.2


4 Configuration and Connections with EUT
4.1 Connection Diagram of EUT and Peripheral Devices

TEST CONFIGURATION

CF Card (F) CFast

RS232 Terminal*4 (G) COM*4 PoE 8


Camera*2 (J)
LAN 2~ 3

9
1 Isolated DIO*2
LCD Monitor (A) DVI-D

3
1 USB 3.0 USB 3.0 HDD (C)
LCD Monitor (A) DVI-I
EUT
7 2
Microphone (I) Audio In USB 3.0 USB Printer (B)

4
6 Audio Out USB 3.0 USB Mouse (D)
Earphone (H)

5
10 USB 3.0 USB Keyboard (E)
AC Adapter (EUT) DC input

11
12
LAN

120Vac
13

Remote site

Notebook PC (K)

Report No.: FD171206D25 Page No. 8 / 27 Report Format Version: 6.1.2


4.2 Configuration of Peripheral Devices and Cable Connections
ID Product Brand Model No. Serial No. FCC ID Remarks
CN082WXD728720CC
24" LCD MONITOR DELL U2410 FCC DoC Approved Provided by Lab
0L2L
A.
CN082WXD728720CC
24" LCD MONITOR DELL U2410 FCC DoC Approved Provided by Lab
0KCL
B. PRINTER HP HP Officejet Pro 251dw N/A N/A Provided by Lab
C. USB 3.0 Hard Disk WD WDBUZG0010BBK-PESN WX61A45JR2YK FCC DoC Approved Provided by Lab
D. USB Mouse Microsoft 1113 9170515772199 FCC DoC Approved Provided by Lab
E. USB Keyboard BTC 5200U G09302046623 E5XKB5122U Provided by Lab
F. CF Card INNODISK CFast 3ME S0011505080100003 N/A Supplied by client
G. RS232 Terminal *4 N/A N/A N/A N/A Supplied by client
H. EARPHONE PHILIPS SBC HL145 N/A N/A Provided by Lab
I. MICROPHONE Labtec mic-333 N/A N/A Provided by Lab
2M Fixed Mini Indoor
J. Dome Network N/A A200MIF-HNG-03 N/A N/A Supplied by client
Camera
K. Notebook PC ASUS PU401L E9NXBC002007372 N/A Provided by Lab
Note:
1. All power cords of the above support units are non-shielded (1.8m).
2. Items K acted as communication partners to transfer data.

Shielding
ID Descriptions Qty. Length (m) Cores (Qty.) Remarks
(Yes/No)
1. DVI cable 2 1.8 Y 2 Provided by Lab
2. USB cable 1 1.5 Y 0 Provided by Lab
3. USB cable 1 0.5 Y 0 Provided by Lab
4. USB cable 1 1.8 Y 1 Provided by Lab
5. USB cable 1 1.5 Y 0 Provided by Lab
6. Audio cable 1 1.2 N 0 Provided by Lab
7. Audio cable 1 2.4 N 0 Provided by Lab
8. LAN cable (Cat. 5e) 2 3.0 N 0 Provided by Lab
9. cable 2 0.5 N 0 Supplied by client
10. DC cable 1 1.15 N 1 Supplied by client
11. AC power cord 1 1.8 N 0 Provided by Lab
12. GND cable 1 1.2 N 0 Provided by Lab
13. LAN cable (Cat. 5e) 1 10 N 0 Provided by Lab
Note: The core(s) is(are) originally attached to the cable(s).

Report No.: FD171206D25 Page No. 9 / 27 Report Format Version: 6.1.2


5 Conducted Emissions at Mains Ports
5.1 Limits
Class A (dBuV) Class B (dBuV)
Frequency (MHz)
Quasi-peak Average Quasi-peak Average
0.15 - 0.5 79 66 66 - 56 56 - 46
0.50 - 5.0 73 60 56 46
5.0 - 30.0 73 60 60 50
Notes: 1. The lower limit shall apply at the transition frequencies.
2. The limit decreases linearly with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.

5.2 Test Instruments

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
ROHDE & SCHWARZ
ESCS 30 838251/021 Nov. 1, 2017 Oct. 31, 2018
TEST RECEIVER
ROHDE & SCHWARZ
ENV216 101195 May 2, 2017 May 1, 2018
Artificial Mains Network (For EUT)
LISN With Adapter (for EUT) AD10 C03Ada-002 May 2, 2017 May 1, 2018
EMCO L.I.S.N. (For peripherals) 3825/2 9504-2359 Jul. 25, 2017 Jul. 24, 2018
SCHWARZBECK
NNLK8129 8129229 May 9, 2017 May 8, 2018
Artificial Mains Network (For EUT)
Software Cond_V7.3.7.4 NA NA NA
RF cable (JYEBAO) With10dB PAD 5D-FB Cable-C03-01 Sep. 19, 2017 Sep. 18, 2018
LYNICS Terminator (For EMCO LISN) 0900510 E1-01-300 Jan. 18, 2017 Jan. 17, 2018
LYNICS Terminator (For EMCO LISN) 0900510 E1-01-301 Jan. 18, 2017 Jan. 17, 2018
ROHDE & SCHWARZ
ESH3-Z5 100220 Nov. 14, 2017 Nov. 13, 2018
Artificial Mains Network (For TV EUT)
LISN With Adapter (for TV EUT) 100220 N/A Nov. 14, 2017 Nov. 13, 2018
Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.
2. The test was performed in Shielded Room No. 3.
3. The VCCI Site Registration No. C-10274.
4. Tested Date: Dec. 11, 2017

Report No.: FD171206D25 Page No. 10 / 27 Report Format Version: 6.1.2


5.3 Test Arrangement
a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected
to the power mains through a line impedance stabilization network (LISN). Other support units were
connected to the power mains through another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c. The test results of conducted emissions at mains ports are recorded of six worst margins for quasi-peak
(mandatory) [and average (if necessary)] values against the limits at frequencies of interest unless the
margin is 20 dB or greater.
Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP) and
average detection (AV) at frequency 0.15MHz-30MHz.

V e r t ic a l G r o u n d
R e f e r e n c e P la n e T e s t R e c e iv e r

EUT
4 0cm

80 cm

L IS N

H o r iz o n ta l G r o u n d
R e fe r e n c e P la n e

N o te : S u p p o r t u n its w e r e c o n n e c t e d to s e c o n d L IS N .

For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.

Report No.: FD171206D25 Page No. 11 / 27 Report Format Version: 6.1.2


5.4 Test Results
Detector Function & Quasi-Peak (QP) /
Frequency Range 150kHz ~ 30MHz
Resolution Bandwidth Average (AV), 9kHz
Environmental
Input Power 120Vac, 60Hz (Adapter) 22℃, 65%RH
Conditions
Tested by Chin-Wen Wang
Test Mode Mode 1

Phase Of Power : Line (L)


Frequency Correction Reading Value Emission Level Limit Margin
No Factor (dBuV) (dBuV) (dBuV) (dB)
(MHz) (dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
1 0.15781 9.57 43.82 38.89 53.39 48.46 79.00 66.00 -25.61 -17.54
2 0.21641 9.58 25.42 9.00 35.00 18.58 79.00 66.00 -44.00 -47.42
3 0.41172 9.58 27.86 27.47 37.44 37.05 79.00 66.00 -41.56 -28.95
4 0.60703 9.59 22.45 22.43 32.04 32.02 73.00 60.00 -40.96 -27.98
5 21.56250 9.90 21.62 14.12 31.52 24.02 73.00 60.00 -41.48 -35.98
6 23.69141 9.91 18.24 10.18 28.15 20.09 73.00 60.00 -44.85 -39.91
Remarks:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level – Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value

Report No.: FD171206D25 Page No. 12 / 27 Report Format Version: 6.1.2


Detector Function & Quasi-Peak (QP) /
Frequency Range 150kHz ~ 30MHz
Resolution Bandwidth Average (AV), 9kHz
Environmental
Input Power 120Vac, 60Hz (Adapter) 22℃, 65%RH
Conditions
Tested by Chin-Wen Wang
Test Mode Mode 1

Phase Of Power : Neutral (N)


Frequency Correction Reading Value Emission Level Limit Margin
No Factor (dBuV) (dBuV) (dBuV) (dB)
(MHz) (dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
1 0.15781 9.73 44.13 40.99 53.86 50.72 79.00 66.00 -25.14 -15.28
2 0.21250 9.74 29.69 12.13 39.43 21.87 79.00 66.00 -39.57 -44.13
3 0.26328 9.74 25.92 25.65 35.66 35.39 79.00 66.00 -43.34 -30.61
4 0.41172 9.74 27.52 27.07 37.26 36.81 79.00 66.00 -41.74 -29.19
5 0.60703 9.75 22.74 22.73 32.49 32.48 73.00 60.00 -40.51 -27.52
6 16.81641 10.09 17.67 9.89 27.76 19.98 73.00 60.00 -45.24 -40.02
7 21.83594 10.15 18.83 10.87 28.98 21.02 73.00 60.00 -44.02 -38.98
Remarks:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level – Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value

Report No.: FD171206D25 Page No. 13 / 27 Report Format Version: 6.1.2


6 Radiated Emissions up to 1 GHz
6.1 Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
Radiated Emissions Limits at 10 meters (dBμV/m)
Frequencies FCC 15B / ICES-003, FCC 15B / ICES-003,
CISPR 22, Class A CISPR 22, Class B
(MHz) Class A Class B
30-88 39 29.5
88-216 43.5 33.1 40 30
216-230
46.4 35.6
230-960
47 37
960-1000 49.5 43.5

Radiated Emissions Limits at 3 meters (dBμV/m)


Frequencies FCC 15B / ICES-003, FCC 15B / ICES-003,
CISPR 22, Class A CISPR 22, Class B
(MHz) Class A Class B
30-88 49.5 40
88-216 54 43.5 50.5 40.5
216-230
56.9 46
230-960
57.5 47.5
960-1000 60 54
Notes: 1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. QP detector shall be applied if not specified.

Report No.: FD171206D25 Page No. 14 / 27 Report Format Version: 6.1.2


6.2 Test Instruments

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
ROHDE & SCHWARZ
ESCI 100412 Sep. 1, 2017 Aug. 31, 2018
TEST RECEIVER
Schwarzbeck
VULB9168 9168-479 Dec. 16, 2016 Dec. 15, 2017
BILOG Antenna
Agilent Preamplifier 8447D 2944A08312 Feb. 21, 2017 Feb. 20, 2018
CT Turn Table TT100 CT-0055 NA NA
CT Tower AT100 CT-0055 NA NA
Software Radiated_V7.6.15.9.5 NA NA NA
ADT RF Switches BOX EM-H-01-1 1002 Sep. 21 2017 Sep. 20, 2018
WOKEN RF cable
8D CABLE-ST6-01 Sep. 21 2017 Sep. 20, 2018
With 5dB PAD
Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
to NML/ROC and NIST/USA.
2. The test was performed in Open Site No. 6.
3. The VCCI Site Registration No. R-728.
4. Tested Date: Dec. 8, 2017

Report No.: FD171206D25 Page No. 15 / 27 Report Format Version: 6.1.2


6.3 Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited test facility.
The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 10 meters away from the interference-receiving antenna, which was mounted on the top
of a variable-height antenna tower.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the
ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of
the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
hold mode when the test frequency is up to 1 GHz.

Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
quasi-peak detection (QP) at frequency up to 1GHz.

Ant. Tower
1- 4m
Variable
10m
EUT&
Support Units

Turn Table

80cm

Ground Plane

Test Receiver

For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.

Report No.: FD171206D25 Page No. 16 / 27 Report Format Version: 6.1.2


6.4 Test Results
Detector Function &
Frequency Range 30MHz ~ 1GHz Quasi-Peak (QP), 120kHz
Resolution Bandwidth
Environmental
Input Power 120Vac, 60Hz 15℃, 80%RH
Conditions
Tested by Vhenson Huang
Test Mode Mode 1

Antenna Polarity & Test Distance : Horizontal at 10 m


Emission Antenna Table Raw Correction
Frequency Limit Margin
No Level Height Angle Value Factor
(MHz) (dBuV/m) (dB)
(dBuV/m) (m) (Degree) (dBuV) (dB/m)
1 49.28 27.68 QP 40.00 -12.32 4.00 H 89 37.00 -9.32
2 85.76 33.51 QP 40.00 -6.49 4.00 H 123 48.23 -14.72
3 118.48 32.03 QP 40.00 -7.97 4.00 H 325 43.53 -11.50
4 141.34 34.71 QP 40.00 -5.29 4.00 H 347 44.03 -9.32
5 154.16 36.30 QP 40.00 -3.70 4.00 H 262 44.93 -8.63
6 222.64 35.78 QP 40.00 -4.22 4.00 H 265 46.76 -10.98
7 308.24 39.58 QP 47.00 -7.42 2.82 H 204 46.48 -6.90
8 462.45 42.83 QP 47.00 -4.17 2.36 H 316 46.81 -3.98
9 530.98 38.56 QP 47.00 -8.44 1.68 H 162 41.57 -3.01
10 616.63 42.29 QP 47.00 -4.71 1.31 H 336 42.81 -0.52
11 839.28 42.89 QP 47.00 -4.11 1.21 H 237 39.32 3.57
12 856.51 41.77 QP 47.00 -5.23 1.00 H 193 38.15 3.62
13 924.92 43.53 QP 47.00 -3.47 1.16 H 69 38.35 5.18
14 999.99 46.47 QP 47.00 -0.53 1.00 H 117 40.64 5.83
Remarks:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
– Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value

Report No.: FD171206D25 Page No. 17 / 27 Report Format Version: 6.1.2


Detector Function &
Frequency Range 30MHz ~ 1GHz Quasi-Peak (QP), 120kHz
Resolution Bandwidth
Environmental
Input Power 120Vac, 60Hz 15℃, 80%RH
Conditions
Tested by Vhenson Huang
Test Mode Mode 1

Antenna Polarity & Test Distance : Vertical at 10 m


Emission Antenna Table Raw Correction
Frequency Limit Margin
No Level Height Angle Value Factor
(MHz) (dBuV/m) (dB)
(dBuV/m) (m) (Degree) (dBuV) (dB/m)
1 45.23 33.38 QP 40.00 -6.62 1.45 V 274 42.88 -9.50
2 85.68 31.18 QP 40.00 -8.82 1.64 V 137 45.90 -14.72
3 119.47 35.40 QP 40.00 -4.60 1.00 V 251 46.85 -11.45
4 140.51 34.18 QP 40.00 -5.82 1.00 V 286 43.62 -9.44
5 154.22 36.89 QP 40.00 -3.11 1.00 V 17 45.52 -8.63
6 216.06 31.30 QP 40.00 -8.70 1.00 V 251 42.50 -11.20
7 308.30 36.33 QP 47.00 -10.67 1.00 V 125 43.23 -6.90
8 462.47 40.26 QP 47.00 -6.74 1.00 V 3 44.24 -3.98
9 616.61 40.92 QP 47.00 -6.08 2.47 V 113 41.44 -0.52
10 839.28 43.58 QP 47.00 -3.42 2.54 V 14 40.01 3.57
11 924.93 42.12 QP 47.00 -4.88 2.83 V 24 36.94 5.18
12 999.99 44.85 QP 47.00 -2.15 2.03 V 305 39.02 5.83
Remarks:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
– Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value

Report No.: FD171206D25 Page No. 18 / 27 Report Format Version: 6.1.2


7 Radiated Emissions above 1 GHz
7.1 Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
Radiated Emissions Limits at 10 meters (dBμV/m)
Frequencies FCC 15B / ICES-003, FCC 15B / ICES-003,
CISPR 22, Class A CISPR 22, Class B
(MHz) Class A Class B
1000-3000 Avg: 49.5 Avg: 43.5 Not defined Not defined
Above 3000 Peak: 69.5 Peak: 63.5 Not defined Not defined

Radiated Emissions Limits at 3 meters (dBμV/m)


Frequencies FCC 15B / ICES-003, FCC 15B / ICES-003,
CISPR 22, Class A CISPR 22, Class B
(MHz) Class A Class B
Avg: 56 Avg: 50
1000-3000
Avg: 60 Avg: 54 Peak: 76 Peak: 70
Peak: 80 Peak: 74 Avg: 60 Avg: 54
Above 3000
Peak: 80 Peak: 74
Notes: 1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
average detector, however, the peak field strength of any emission shall not exceed the maximum
permitted average limits, specified above by more than 20dB under any condition of modulation.
Frequency Range (For unintentional radiators)
Highest frequency generated or used in the device or
Upper frequency of measurement range (MHz)
on which the device operates or tunes (MHz)
Below 1.705 30
1.705-108 1000
108-500 2000
500-1000 5000
5th harmonic of the highest frequency or 40GHz,
Above 1000
whichever is lower

Report No.: FD171206D25 Page No. 19 / 27 Report Format Version: 6.1.2


7.2 Test Instruments

Description & Manufacturer Model No. Serial No. Cal. Date Cal. Due
Agilent Spectrum E4446A MY51100009 Jun. 1, 2017 May 31, 2018
Agilent Test Receiver N9038A MY51210137 Jun. 23, 2017 Jun. 22, 2018
Agilent Preamplifier 8449B 3008A01292 Feb. 22, 2017 Feb. 21, 2018
MITEQ Preamplifier AMF-6F-260400-33-8P 892164 Feb. 21, 2017 Feb. 20, 2018
EMCI Preamplifier EMC184045B 980235 Feb. 22, 2017 Feb. 21, 2018
Schwarzbeck Horn Antenna BBHA-9170 212 Dec. 30, 2016 Dec. 29, 2017
EMCO Horn Antenna 3115 6714 Dec. 29, 2016 Dec. 28, 2017
Max Full. Turn Table MF7802 MF780208216 NA NA
Software Radiated_V8.7.08 NA NA NA
SUHNER RF cable
SF102 Cable-CH10-3.6m Aug. 14, 2017 Aug. 13, 2018
With 3/4dB PAD
MICRO-TRONICS
BRC50703-01 010 May 31, 2017 May 30, 2018
Notch filter
MICRO-TRONICS
BRM17690 005 May 31, 2017 May 30, 2018
Band Pass Filter
Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
to NML/ROC and NIST/USA.
2. The test was performed in Chamber No. 10.
3. The Industry Canada Reference No. IC 7450E-11.
4. The VCCI Site Registration No. G-10427
5. Tested Date: Dec. 11, 2017

Report No.: FD171206D25 Page No. 20 / 27 Report Format Version: 6.1.2


7.3 Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited chamber
room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
of a variable-height antenna tower.
c. The height of antenna can be varied from one meter to four meters, the height of adjustment depends on
the EUT height and the antenna 3dB beamwidth both, to detect the maximum value of the field strength.
Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
heights and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The spectrum analyzer system was set to peak and average detect function and specified bandwidth with
maximum hold mode when the test frequency is above 1 GHz.

Note: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video bandwidth is 3MHz for
Peak detection (PK) at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz.

Ant. Tower
1-4m*
Variable
EUT & 3m
Support Units

Turn Table
Absorber

80cm

Ground Plane

Spectrum analyzer

* : depends on the EUT height and the antenna 3dB beamwidth both.

For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.

Report No.: FD171206D25 Page No. 21 / 27 Report Format Version: 6.1.2


7.4 Test Results
Detector Function & Peak (PK) /
Frequency Range 1GHz ~ 20GHz
Resolution Bandwidth Average (AV), 1MHz
Environmental
Input Power 120Vac, 60Hz 20℃, 70%RH
Conditions
Tested by ED.Lin
Test Mode Mode 1

Antenna Polarity & Test Distance : Horizontal at 3 m


Emission Antenna Table Raw Correction
Frequency Limit Margin
No Level Height Angle Value Factor
(MHz) (dBuV/m) (dB)
(dBuV/m) (m) (Degree) (dBuV) (dB/m)
1 1233.23 59.20 PK 80.00 -20.80 1.00 H 48 64.29 -5.09
2 1233.23 52.32 AV 60.00 -7.68 1.00 H 48 57.41 -5.09
3 2309.97 57.65 PK 80.00 -22.35 2.38 H 236 59.22 -1.57
4 2309.97 42.30 AV 60.00 -17.70 2.38 H 236 43.87 -1.57
5 2774.76 59.28 PK 80.00 -20.72 1.00 H 242 59.22 0.06
6 2774.76 49.65 AV 60.00 -10.35 1.00 H 242 49.59 0.06
Remarks:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
– Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value

Report No.: FD171206D25 Page No. 22 / 27 Report Format Version: 6.1.2


Detector Function & Peak (PK) /
Frequency Range 1GHz ~ 20GHz
Resolution Bandwidth Average (AV), 1MHz
Environmental
Input Power 120Vac, 60Hz 20℃, 70%RH
Conditions
Tested by ED.Lin
Test Mode Mode 1

Antenna Polarity & Test Distance : Vertical at 3 m


Emission Antenna Table Raw Correction
Frequency Limit Margin
No Level Height Angle Value Factor
(MHz) (dBuV/m) (dB)
(dBuV/m) (m) (Degree) (dBuV) (dB/m)
1 2127.43 60.64 PK 80.00 -19.36 1.00 V 283 62.73 -2.09
2 2127.43 41.46 AV 60.00 -18.54 1.00 V 283 43.55 -2.09
3 2310.01 60.60 PK 80.00 -19.40 1.94 V 203 62.17 -1.57
4 2310.01 47.72 AV 60.00 -12.28 1.94 V 203 49.29 -1.57
5 3853.87 58.20 PK 80.00 -21.80 2.44 V 228 54.57 3.63
6 3853.87 44.22 AV 60.00 -15.78 2.44 V 228 40.59 3.63
Remarks:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
– Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value

Report No.: FD171206D25 Page No. 23 / 27 Report Format Version: 6.1.2


8 Pictures of Test Arrangements
8.1 Conducted Emissions at Mains Ports

Report No.: FD171206D25 Page No. 24 / 27 Report Format Version: 6.1.2


8.2 Radiated Emissions up to 1 GHz

Report No.: FD171206D25 Page No. 25 / 27 Report Format Version: 6.1.2


8.3 Radiated Emissions above 1 GHz

Report No.: FD171206D25 Page No. 26 / 27 Report Format Version: 6.1.2


Appendix – Information on the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and
approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab Hsin Chu EMC/RF/Telecom Lab


Tel: 886-2-26052180 Tel: 886-3-6668565
Fax: 886-2-26051924 Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab


Tel: 886-3-3183232
Fax: 886-3-3270892

Email: [email protected]
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.

--- END ---

Report No.: FD171206D25 Page No. 27 / 27 Report Format Version: 6.1.2

You might also like