0% found this document useful (0 votes)
30 views6 pages

3RP25051BW30 Datasheet

The document provides detailed technical specifications for a SIRIUS timing relay with model number 3RP2505-1BW30. It includes information on 27 possible functions, voltage and current ratings, switching capacity, electromagnetic compatibility, safety data, and terminal connection types and sizes.

Uploaded by

Jackson
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views6 pages

3RP25051BW30 Datasheet

The document provides detailed technical specifications for a SIRIUS timing relay with model number 3RP2505-1BW30. It includes information on 27 possible functions, voltage and current ratings, switching capacity, electromagnetic compatibility, safety data, and terminal connection types and sizes.

Uploaded by

Jackson
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Data sheet 3RP2505-1BW30

Timing relay, Multifunction 2 change-over contacts, 27 functions 7 time


ranges (0.05 s...100 h) 12-240 V AC/DC at 50/60 Hz AC with LED, Screw
terminal

product brand name SIRIUS


product designation timing relay
design of the product 27 functions
product type designation 3RP25
General technical data
product component
● relay output Yes
● semi-conductor output No
product extension required remote control No
product extension optional remote control No
insulation voltage for overvoltage category III according to 300 V
IEC 60664 with degree of pollution 3 rated value
test voltage for isolation test 2.5 kV
degree of pollution 3
surge voltage resistance rated value 4 000 V
protection class IP IP20
shock resistance acc. to IEC 60068-2-27 11g / 15 ms
vibration resistance acc. to IEC 60068-2-6 10 ... 55 Hz / 0.35 mm
mechanical service life (switching cycles) typical 10 000 000
electrical endurance (switching cycles) at AC-15 at 230 V 100 000
typical
adjustable time 0.05 s ... 100 h
relative setting accuracy relating to full-scale value 5%
thermal current 5A
minimum ON period 35 ms
recovery time 250 ms
reference code acc. to IEC 81346-2 K
relative repeat accuracy 1%
Substance Prohibitance (Date) 12.09.2014 00:00:00
Control circuit/ Control
type of voltage of the control supply voltage AC/DC
control supply voltage 1 at AC
● at 50 Hz 12 ... 240 V
● at 60 Hz 12 ... 240 V
control supply voltage frequency 1 50 ... 60 Hz
● control supply voltage 1 at DC 12 ... 240 V
operating range factor control supply voltage rated
value at DC

3RP25051BW30 Subject to change without notice


3.11.2021
Page 1/2 © Copyright Siemens
● initial value 0.8
● full-scale value 1.1
operating range factor control supply voltage rated
value at AC at 50 Hz
● initial value 0.8
● full-scale value 1.1
operating range factor control supply voltage rated
value at AC at 60 Hz
● initial value 0.8
● full-scale value 1.1
inrush current peak
● at 24 V 0.3 A
● at 240 V 5A
duration of inrush current peak
● at 24 V 0.3 ms
● at 240 V 0.5 ms
Switching Function
switching function
● ON-delay Yes
● ON-delay/instantaneous contact Yes
● passing make contact Yes
● passing make contact/instantaneous contact Yes
● OFF delay No
switching function
● flashing symmetrically with interval Yes
start/instantaneous
● flashing symmetrically with interval start Yes
● flashing symmetrically with pulse Yes
start/instantaneous
● flashing symmetrically with pulse start Yes
● flashing asymmetrically with interval start No
● flashing asymmetrically with pulse start No
switching function
● star-delta circuit with delay time No
● star-delta circuit Yes
switching function with control signal
● additive ON-delay Yes
● passing break contact Yes
● passing break contact/instantaneous Yes
● OFF delay Yes
● OFF delay/instantaneous Yes
● pulse delayed Yes
● pulse delayed/instantaneous Yes
● pulse-shaping Yes
● pulse-shaping/instantaneous Yes
● additive ON-delay/instantaneous Yes
● ON-delay/OFF-delay/instantaneous Yes
● passing make contact Yes
● passing make contact/instantaneous contact Yes
switching function of interval relay with control signal
● retrotriggerable with deactivated control Yes
signal/instantaneous contact
● retrotriggerable with switched-on control signal Yes
● retrotriggerable with switched-on control Yes
signal/instantaneous contact
● retriggerable with deactivated control signal Yes
design of the control terminal non-floating Yes
Short-circuit protection
design of the fuse link for short-circuit protection of the fuse gL/gG: 4 A
auxiliary switch required

3RP25051BW30 Subject to change without notice


3.11.2021
Page 2/3 © Copyright Siemens
Auxiliary circuit
material of switching contacts AgSnO2
number of NC contacts delayed switching 0
number of NO contacts delayed switching 0
number of CO contacts delayed switching 2
operational current of auxiliary contacts at AC-15
● at 24 V 3A
● at 250 V 3A
operational current of auxiliary contacts at DC-13
● at 24 V 1A
● at 125 V 0.2 A
● at 250 V 0.1 A
operating frequency with 3RT2 contactor maximum 5 000 1/h
contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching operations (17
V, 5 mA)
contact rating of auxiliary contacts according to UL R300 / B300
influence of the surrounding temperature 1% in the whole temperature range to the set runtime
power supply influence 1% in the whole voltage range to the set runtime
switching capacity current with inductive load 0.01 ... 3 A
Inputs/ Outputs
product function
● at the relay outputs switchover delayed/without Yes
delay
● non-volatile No
Electromagnetic compatibility
EMC immunity acc. to IEC 61812-1 EN 61000-6-2
conducted interference
● due to burst acc. to IEC 61000-4-4 2 kV network connection / 1 kV control connection
● due to conductor-earth surge acc. to IEC 61000-4-5 2 kV
● due to conductor-conductor surge acc. to IEC 1 kV
61000-4-5
field-based interference acc. to IEC 61000-4-3 10 V/m
electrostatic discharge acc. to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge
Safety related data
type of insulation Basic insulation
category acc. to EN 954-1 none
Connections/ Terminals
product function removable terminal for auxiliary and Yes
control circuit
type of electrical connection for auxiliary and control circuit screw-type terminals
type of connectable conductor cross-sections
● solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²)
● at AWG cables solid 1x (20 ... 12), 2x (20 ... 14)
● at AWG cables stranded 1x (20 ... 12), 2x (20 ... 14)
● connectable conductor cross-section solid 0.5 ... 4 mm²
● connectable conductor cross-section finely stranded 0.5 ... 4 mm²
with core end processing
● AWG number as coded connectable conductor 20 ... 12
cross section solid
● AWG number as coded connectable conductor 20 ... 14
cross section stranded
tightening torque 0.6 ... 0.8 N·m
design of the thread of the connection screw M3
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm standard mounting rail
height 100 mm
width 22.5 mm

3RP25051BW30 Subject to change without notice


3.11.2021
Page 3/4 © Copyright Siemens
depth 90 mm
required spacing
● with side-by-side mounting
— forwards 0 mm
— backwards 0 mm
— upwards 0 mm
— downwards 0 mm
— at the side 0 mm
● for grounded parts
— forwards 0 mm
— backwards 0 mm
— upwards 0 mm
— at the side 0 mm
— downwards 0 mm
● for live parts
— forwards 0 mm
— backwards 0 mm
— upwards 0 mm
— downwards 0 mm
— at the side 0 mm
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
● ambient temperature during operation -25 ... +60 °C
● ambient temperature during storage -40 ... +85 °C
● ambient temperature during transport -40 ... +85 °C
relative humidity during operation 10 ... 95 %
Certificates/ approvals
Declaration of
General Product Approval EMC
Conformity

Miscellaneous

Declaration of
Test Certificates Marine / Shipping
Conformity

Type Test Special Test


Certificates/Test Certificate
Report

Marine / Shipping other

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RP2505-1BW30
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP2505-1BW30

3RP25051BW30 Subject to change without notice


3.11.2021
Page 4/5 © Copyright Siemens
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RP2505-1BW30
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP2505-1BW30&lang=en
Characteristic: Derating
https://support.industry.siemens.com/cs/ww/en/ps/3RP2505-1BW30/manual

3RP25051BW30 Subject to change without notice


3.11.2021
Page 5/6 © Copyright Siemens
last modified: 1/18/2021

3RP25051BW30 Subject to change without notice


3.11.2021
Page 6/6 © Copyright Siemens

You might also like