Aeon7200A Anesthesia Machine

Full Configuration
• With CE certificate, meets EU clinical safety requirement

• Large 8.4" LCD color touchscreen, monitoring of waveforms and parameters in different colors

• IPPV, Pressure, and SIMV modes can easily meet clinical requirements

• 6-tubes of flowmeters for 3-gas sources and suitable for various operation requirements

• Spirometry loops, for easier interpretation of ventilation effectiveness

• Optional multi-gas monitoring provides more reference for anesthesia

• Optional AGSS provides more protection

Technical Specifications
Physical & Environmental Specifications • Setting: Touchscreen and Navigator knob
• Dimensions(H×W×D): 1356×845×620 mm • Tidal volume: 20~1500 ml
• Weight: 110 kg (basic unit) • Ventilation frequency: 2~100 bpm
• Storage temperature: -20~55℃ • I:E ratio: 4:1~1:8
• Working temperature: 10~40℃ • PEEP: 0~30 cmH 2O (optional)
• Storage humidity: ≤93% • Inspiratory plateau: OFF, 5%~60%
Electrical Specifications • Flow trigger: 1~15 L/min
• Mains: AC 100~240 V, 50/60 Hz • Pressure trigger: -20~0 cmH 2O
• Battery: DC 24 V, minimum 120min • Pressure range: 5~70 cmH 2O
• Mains outlet: 3 (1.5A individual) • Monitoring display: Pressure: P peak, P plat, P mean, PEEP
Pneumatic Specifications Volumes: MV, Vt
• Gas supply: 0.28~0.6 MPa Freq.
• Flowmeters: O 2: 0~1 L/min; 1~10 L/min Compliance
N 2O: 0~1 L/min; 1~10 L/min Gas: O2, CO2, Agent (all optional)
Air: 0~1 L/min; 1~12 L/min • Graph display: P-t, F-t waveforms, P-V, F-V loops
• Gas system: Oxygen supply failure protection • Alarm: Audible and Visual alarms
• O 2 flush: 25~75 L/min High/Low Airway Pressure
• Working mode: Closed, Semi-closed, Semi-open High/Low Minute Volume
• Driven mode: Pneumatically driven and High/Low FiO 2 (when FiO 2 function is enabled)
electronically controlled Power failure
• Safety valve: ≤10 kPa O 2 Supply failure, Apnea, ......
• Operating mode: One key Man. / Vent. swich • Alarm Silence: ≤120 s
• Cylinder yokes: Optional Vaporizer
Ventilator Specifications • Supports 2 vaporizers (Selectatec ® with interlock, optional
• Patient type: Adult, Pediatric standby vaporizer parking holder )
• Ventilation modes: IPPV, PLV, SIMV, Spont (with apnea backup), • Agent type: Halothane, Enflurane, Isoflurane, Sevoflurane
Manual, Standby • Filling type: Pour-fill, Key-fill, Quik-fil ®
Remark: Above configurations include standard and option. Please check price with your Aeonmed
sales representative.

HQ:Building 9, No.26 Outer Ring West Road, Fengtai District, Beijing 100070, China
Science Park:No. 10, Chaobai Street, Yanjiao Development Zone, Sanhe City, Hebei Province
065201, China
TEL: +86-10-5841 1198 FAX: +86-10-6371 8989
Http: //www.aeonmed.com E-mail: [email protected]
The information contained in this leaflet is correct at the date to publication. The policy of Beijing Aeonmed Co., Ltd. is one of the continued improvement to its products.
Because of this policy, Aeonmed reserves the right to make any change, which may affect the information in this leaflet without giving prior notices.