Troubleshooting DSP NEXT2
Troubleshooting DSP NEXT2
TROUBLESHOOTING
Appearance of DSP-75WT5N2
Motor
Important parts
•Air end block
•Main motor
•Starter panel
Air end •Suction throttle valve
•Check valve
Filter
•Intake filter
•Oil filter
Cooling system
•Oil cooler
•After/inter cooler
•Dryer
Air Exhaust
Air Inhale
Cause
①Dirt of intake filter
②Rising of intake temp.
③Unloading pressure rising because of leaking from check valve
④Rising of coolant temp.
⑤Performance decline of air end block
Counter
①Cleaning and replacement of intake filter
②Improvement of ventilation(Below 40℃)
③Replacement of check valve
④Cleaning of cooler, Check of coolant
⑤Replacement to new air end
PC board trouble
Phenomenon:
malfunction, abnormal operation
Cause:
Burnout of PCB because of rain water
invasion from ducting
Short circuit by dust
Corrosion of contact by gas
Noise from INV production, invasion
from ground wire
Burnout of PCB by invasion of current
from ground by thunder
Countermeasure:
To check the cooling fans when
compressor is running. This is just
the same manner as solenoid valves
MGSW Trouble
Countermeasure:
Check the wiring connection
Check the MGSW contact surface
Check the supply voltage all 3 phase
Clean inside of starter panel
Motor trouble
Phenomenon:
Main motor burnout
Abnormal noise from bearing
Cause:
Cooling failure・・・Insufficient ventilation
Short cuircuit
Deposition of dust
Motor trouble
Motor spec. : 37kW AEEFUH 4P 200V
《Phenomenon》
ELB was tripped …
Installation conditions:semi-outdoor
《Cause》
When checking the motor cooling fan,
there were piles of dust and dirt stuck on
to the motor. The motor couldn’t get
enough cooling path therefore the motor
coil was damaged in result
Piles of dirt stuck on to
《Countermeasure》
Conduct maintenance of the motor suction side, and blocked
including bearing. the cooling path