Product specifications

Eaton 174439

Catalog Number: 174439

Eaton Moeller series Power Defense - Molded Case Circuit


Breaker. Circuit-breaker LZM, 4 p, 250A, N2-4-A250-I

General specifications

Product Name Catalog Number


Eaton Moeller series Power Defense 174439
molded case circuit-breaker
EAN
4015081709014

Product Length/Depth Product Height


149 mm 184 mm

Product Width Product Weight


140 mm 3 kg

Compliances Certifications
RoHS conform VDE 0660

Photo is representative IEC/EN 60947


IEC
Delivery program Technical data - electrical

Circuit breaker frame type Voltage rating


LZM2 690 V - 690 V

Application Voltage rating (DC)


Use in unearthed supply systems at 690 V 750 VDC

Amperage Rating Rated insulation voltage (Ui)


250 A 1000 V AC

Number of poles Rated impulse withstand voltage (Uimp) at auxiliary contacts


Four-pole 6000 V

Rated impulse withstand voltage (Uimp) at main contacts


8000 V

Rated operational current


250 A (660-690 V AC-3, making and breaking capacity)
250 A (750 V DC-1, making and breaking capacity)
300 A (690 V AC-1, making and breaking capacity)
300 A (415 V AC-1, making and breaking capacity)
250 A (415 V AC-3, making and breaking capacity)
300 A (380/400 V AC-1, making and breaking capacity)
250 A (500 V DC-1, making and breaking capacity)
250 A (500 V DC-3, making and breaking capacity)
250 A (750 V DC-3, making and breaking capacity)

Current rating of neutral conductor


200% of phase conductor

Rated short-time withstand current (t = 0.3 s)


1.9 kA

Rated short-time withstand current (t = 1 s)


1.9 kA

Instantaneous current setting (Ii) - min


1500 A

Instantaneous current setting (Ii) - max


2500 A

Overload current setting (Ir)


200 A - 250 A

Overload current setting (Ir) - min


200 A

Overload current setting (Ir) - max


250 A

Short delay current setting (Isd) - min


0A
Technical data - mechanical
Short delay current setting (Isd) - max
0A Type
Circuit breaker
Short-circuit release non-delayed setting - min
1500 A Release system
Thermomagnetic release
Short-circuit release non-delayed setting - max
2500 A Mounting Method
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230
V, 50/60 Hz Built-in device fixed built-in technique
85 kA Fixed

Rated short-circuit breaking capacity Ics (IEC/EN 60947) at Degree of protection


400/415 V, 50/60 Hz
In the area of the HMI devices: IP20 (basic protection type)
50 kA
IP20

Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440


Degree of protection (IP), front side
V, 50/60 Hz
IP66 (with door coupling rotary handle)
35 kA
IP40 (with insulating surround)
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525
V, 50/60 Hz Degree of protection (terminations)
25 kA IP10 (tunnel terminal)
IP00 (terminations, phase isolator and band terminal)
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz
187 kA Protection against direct contact
Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz
110
105 kA
Shock resistance
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz
20 g (half-sinusoidal shock 20 ms)
74 kA
Number of auxiliary contacts (change-over contacts)
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz
0
53 kA
Number of auxiliary contacts (normally closed contacts)
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
0
40 kA
Number of auxiliary contacts (normally open contacts)
Short-circuit total breaktime
0
< 10 ms
Number of operations per hour - max
Electrical connection type of main circuit
120
Screw connection
Handle type
Isolation
Rocker lever
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts) Position of connection for main current circuit
Front side
Overvoltage category
III Direction of incoming supply
As required
Utilization category
A (IEC/EN 60947-2)
Standard terminals

Pollution degree Screw terminal

3
Terminal capacity (control cable)

Lifespan, electrical 0.75 mm² - 2.5 mm² (1x)

3000 operations at 750 V DC-3 0.75 mm² - 1.5 mm² (2x)

5000 operations at 690 V AC-3


Terminal capacity (aluminum solid conductor/cable)
10000 operations at 400 V AC-1
16 mm² (1x) at tunnel terminal
7500 operations at 690 V AC-1
7500 operations at 750 V DC-1 Terminal capacity (copper busbar)
3000 operations at 500 V DC-3 Min. 16 mm x 5 mm direct at switch rear-side connection
10000 operations at 415 V AC-1 M8 at rear-side screw connection
6500 operations at 400 V AC-3 Max. 20 mm x 5 mm direct at switch rear-side connection
6500 operations at 415 V AC-3
Terminal capacity (copper solid conductor/cable)
7500 operations at 500 V DC-1
4 mm² - 16 mm² (1x) direct at switch rear-side connection
4 mm² - 16 mm² (2x) at box terminal
4 mm² - 16 mm² (1x) at box terminal
4 mm² - 16 mm² (2x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal

Terminal capacity (copper stranded conductor/cable)


25 mm² - 70 mm² (2x) at box terminal
25 mm² - 185 mm² (1x) at box terminal
25 mm² - 185 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) at tunnel terminal

Terminal capacity (copper strip)


Max. 10 segments of 16 mm x 0.8 mm at box terminal
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection
(punched)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection
(punched)

Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Lifespan, mechanical
20000 operations

Design verification as per IEC/EN 61439 - technical Design verification as per IEC/EN 61439
data
10.2.2 Corrosion resistance
Rated operational current for specified heat dissipation (In) Meets the product standard's requirements.
250 A
10.2.3.1 Verification of thermal stability of enclosures
Equipment heat dissipation, current-dependent Meets the product standard's requirements.
58.13 W
10.2.3.2 Verification of resistance of insulating materials to
normal heat
Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal


elect. effects
Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation


Meets the product standard's requirements.

10.2.5 Lifting
Does not apply, since the entire switchgear needs to be
evaluated.

10.2.6 Mechanical impact


Does not apply, since the entire switchgear needs to be
evaluated.

10.2.7 Inscriptions
Meets the product standard's requirements.

10.3 Degree of protection of assemblies


Does not apply, since the entire switchgear needs to be
evaluated.

10.4 Clearances and creepage distances


Meets the product standard's requirements.

10.5 Protection against electric shock


Does not apply, since the entire switchgear needs to be
evaluated.

10.6 Incorporation of switching devices and components


Does not apply, since the entire switchgear needs to be
evaluated.

10.7 Internal electrical circuits and connections


Is the panel builder's responsibility.

10.8 Connections for external conductors


Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength


Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage


Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material


Is the panel builder's responsibility.

10.10 Temperature rise


The panel builder is responsible for the temperature rise
calculation. Eaton will provide heat dissipation data for the
devices. Additional information

10.11 Short-circuit rating Features


Is the panel builder's responsibility. The specifications for the Motor drive optional
switchgear must be observed. Protection unit

10.12 Electromagnetic compatibility Functions


Is the panel builder's responsibility. The specifications for the System and cable protection
switchgear must be observed.
Special features
10.13 Mechanical function
The device meets the requirements, provided the information in Maximum back-up fuse, if

the instruction leaflet (IL) is observed. the expected short-circuit


currents at the installation
location exceed the
switching capacity of the
circuit breaker (Rated short-
circuit breaking capacity Icn)
Rated current = rated
uninterrupted current: 250 A
Set value in neutral
conductor is synchronous
with set value Ir of main
pole.

Resources

Certification reports
DA-DC-03_N2

Characteristic curve
eaton-circuit-breaker-let-through-current-nzm-mccb-characteristic-curve-
004.eps

eaton-circuit-breaker-nzm-mccb-characteristic-curve-050.eps

eaton-circuit-breaker-characteristic-power-defense-mccb-characteristic-
curve-036.eps

Drawings
eaton-circuit-breaker-nzm-mccb-dimensions-035.eps

eaton-circuit-breaker-switch-nzm-mccb-dimensions-017.eps

Installation instructions
IL01206012Z

Installation videos
Power Defense EMEA
Eaton Corporation plc
Eaton House
30 Pembroke Road Eaton is a registered trademark.
Dublin 4, Ireland
Eaton.com All other trademarks are
© 2024 Eaton. All Rights property of their respective
Reserved. owners. Eaton.com/socialmedia

You might also like