AVK FIRE Pricelist 2024
AVK FIRE Pricelist 2024
Introduction 4 Series 145, Flanged gate valves, 11 Series 96, Micro and limit switches 21
AWWA
10-Year warranty 6 Series 45, Flanged gate valves, 12 Series 20, Mounting kit for micro 21
AWWA switch
UL/FM approvals 7 Series 55, Flanged gate valves, 14 Series 27, Dry barrel fire hydrants, 22
DN450-600 AWWA
Series 06, Flanged gate valves, 18 Series 24, Wet barrel fire hydrants, 25
short DIN F4 AWWA
Series 06, Gate valves with 18 Series 96, Micro and limit switches 25
grooved ends
Series 36, Gate valves with PE 18 Series 75, Centric butterfly valves 26
ends with fixed liner
2
TABLE OF CONTENTS
Fire hydrants used in water supply
3
THE AVK GROUP
DEDICATED PEOPLE
AVK
4,800+ employees,
hereof approx. 250 in
AVK International A/S
GLOBAL ORGANISATION
100+ AVK companies
worldwide YOUR
CONTINUOUS GROWTH
Net turnover EUR 1053 LONG-TERM
PARTNER
million (2022/23)
4
AVK has been in the valve business for more than 50 years.
Today AVK is a global market leader within water supply,
fire protection, wastewater treatment and gas distribution.
| 5
10-YEAR WARRANTY
AVK manufactured products are guaranteed against defects in workmanship and material used for a period of 10 years from
the date of the passing of risks to the buyer (Incoterms 2020). This warranty shall only be valid subject to the below terms
and conditions.
This warranty shall not apply: (i) if the AVK product is used for an application for which it has not been designed or which has
not been recommended by AVK; (ii) in case of changes to the chemical composition of the medium or treatment of the medium
for which the AVK products is used, unless such change has been preapproved in writing by AVK; (iii) if the AVK product has
not been installed in accordance with AVK installation instructions, if any, and accepted codes of good practice; (iv) in case of
lack of or faulty maintenance; (v) in case of normal wear and tear or (vi) in case of use in electronic products, incl. VIDI products.
The buyer shall immediately notify AVK of any defective product claim. AVK shall have the right to inspect said AVK product,
and the buyer shall, if requested, return the defective AVK product to AVK with transportation prepaid. The buyer shall assume
all responsibility and expenses for removal, reinstallation and freight charges in connection to the foregoing remedy.
The obligation under this warranty shall be limited to adjustment, repair or replacement of the defective AVK products, ex works
point of sale, at AVK’s option. AVK shall accept no liability for product failure caused by abnormal operation conditions, war,
violence, storm, cataclysm or any other cases of force majeure.
In no event shall AVK be liable to the buyer or to any third party for loss of profits, loss of revenue, loss of business opportunity,
loss of time or for any indirect, incidental, special, consequential, punitive or exemplary damages arising out of or related to
any AVK products provided by AVK.
Any product which has been supplied but not manufactured by AVK shall be subject to the warranty terms of the manufacturer.
The decision of AVK in relation to any claims or disputes over this warranty shall be final. This warranty shall be in addition to
AVK’s general terms and conditions of sale or any other specific conditions of contract which may govern the supply of AVK
products, and this warranty shall apply when the warranty obligations according to such terms have expired.
Kind regards
WARRANT
R
10-YEA
Morten S. Nielsen
Chairman AVK Water
6 |
EXPECT US TO EXCEED
MARKET STANDARDS
Expect... AVK
In our business there are five cornerstones that
must be in place in order to meet customer
expectations: Quality, reliability, innovation,
sustainability and customer service.
AVK products with UL & FM approval UL standards AVK wet barrel fire hydrants series 24
Since we always aim at the highest quality, most Underwriters Laboratories (UL) is a product UL 246 standard for hydrants for fire
of our products for fire protection applications safety testing and certification company having protection service:
are approved according to both UL and FM. We developed more than 1,600 standards. UL is These requirements cover the performance of
have thus committed to meet the standards and certifying, validating, testing, verifying, inspecting, and methods for testing hydrants intended for
requirements set by these well-recognized global auditing, advising and educating customers in use in piping systems supplying water for fire
organisations and to continuously test and control 100+ countries. protection service.
our product ranges accordingly.
In order to become UL Listed, a representative The UL 246 approval tests include a 10-day
Our UL listed and FM approved products count sample of the product to be listed must be moist ammonia air stress cracking test, testing
dry and wet barrel hydrants, butterfly valves, NRS tested and meet the safety requirements set. of rubber parts according to UL 157 and tests of
gate valves, OS&Y gate valves, post indicators, Products having the UL mark are covered by the operation, leakage and head loss.
wall post indicators and swing check valves. Underwriters Laboratories follow-up program,
which continuously tests the products to ensure FM class number 1511:
FM Approval that the UL standards and requirements are Shell strength is tested by a pressure of four
FM Global is a property insurance company always met. times the working pressure lasting for five
operating from the philosophy that most losses minutes, and after the test there should be no
can be prevented. They provide insurance evidence of damage. The standard also includes
products and property loss prevention testing seat leakage at two times working
engineering services to protect their clients’ pressure for five minutes without damage or
worldwide operations. leakage to be seen.
FM Approval is part of the FM Global Group and Furthermore, hose outlet strength, stem strength
it is a testing and certification service. Products and head loss are tested.
that pass the five-step approval process are
issued the globally acknowledged FM mark to
support property loss prevention and to signify
that they will perform as expected.
8
AVK dry barrel fire hydrants series 27 AVK gate valves series 45, 55 and 145 Furthermore, the FM standard also dictates tests
The UL 246 standard for hydrants for fire UL 262 standard for gate valves for fire of valve assembly strength, ultimate operator
protection service: protection service: torque, durability, close quarters durability
Same as mentioned under series 24. These requirements cover gate valves intended (butterfly type), friction loss determination, water
The UL 246 approval tests include a 10-day for installation in piping systems supplying water hammer, indicator strength, water absorption,
moist ammonia air stress cracking test, testing for fire protection service. aging, corrosion protection coating and much
of rubber parts according to UL 157 and tests of more.
operation, leakage and head loss. The UL 262 standard includes a 10-day moist
ammonia air stress cracking test, test of rubber AVK check valves series 5190
FM class number 1510: parts according to UL 157, test of coating for AVK series 5190 products for fire protection meet
Shell strength is tested by a pressure of four seating surfaces and corrosion test for stems. the UL 312 standard. The products 5190/10-001
times the working pressure lasting for five and 5190/20-001 are furthermore approved
minutes, and after the test there should be no FM class number 1120 and 1130: according to the FM 1210 standard.
evidence of damage. The standard also includes The valve body, cover and bonnet are subjected
testing seat leakage at two times working to a hydrostatic test of four times working UL 312 Standard for check valves for fire
pressure for five minutes without damage or pressure (or at least 48 bar) for five minutes protection service:
leakage to be seen. and there should be no sustaining cracking or These requirements cover check valves DN25
permanent distortion. and larger, used in piping systems supplying
Furthermore, hose outlet strength, stem water for fire protection service. The UL 312
strength and head loss are tested, and finally, Stem seal leakage is tested on a partially open approval tests include a cycling performance test,
the breakable system is tested by a pressurized valve subjected to working pressure for five testing of rubber parts, adhesion test for resilient
hydrant (at maximum working pressure) being minutes. No visible stem leakage must appear. seat materials and leakage test.
hit with a force sufficient enough to break. After Both resilient and metal seats are also leakage
separation, the hydrant must have a leakage tested. FM class number 1210:
of maximum 19 dm³/min while pressure is The valve is subject to a cycle test of 50,000
maintained for two minutes. Furthermore, rubber parts are tested for water cycles, no more than six cycles per minute. The
absorption, corrosion protection coating, aging test is carried out at atmospheric pressure and
AVK post indicators series 34 and bonding adequacy and the strength of gate, no excessive wear, damage or failure of any valve
UL 789 standard for indicator posts for fire stem seal, indicator post and handle are tested. component must occur. Seat leakage tests are
protection service: performed on resilient seat and metal-to-metal
These requirements cover indicator posts, AVK butterfly valves series 75 (indicating seats. For the resilient seat, no leakage is allowed
including wall and underground types, for use in valves) during test with hydrostatic pressure of 2, 6.8
operating valves of the inside-screw pattern and FM class number 1112 and 12 bar (and working pressure if higher than
for indicating the position of the gates in such Disc strength is tested at two times working 12 bar) for five minutes each.
valves. Indicator posts are primarily intended pressure held for five minutes and repeated for
for use with valves controlling water supplies both directions. Hydrostatic strength is tested For the metal-to-metal seat, leakage must not
to sprinkler, deluge, water spray, foam, and at a hydrostatic pressure of four times working exceed a value of approximately 11.8 ml/hour per
standpipe systems used in private fire service pressure (or at least 48 bar) for five minutes. No centimeter of nominal valve size when subjected
where connections enter buildings. visible rupture, cracking or permanent distortion to 2, 6.8 and 12 bar (and working pressure if
of the valve body must be seen. higher than 12 bar) for five minutes each.
The UL 789 standard includes test of rotating and
moving target mechanisms of position indicators Seat leakage is tested at working pressure and at In addition, clapper strength, hydrostatic strength,
and performance tests involving a 1,000 cycle 125% of working pressure for five minutes each. friction loss determination, bonding adequacy,
operation test of polymeric parts. If there is any leakage, this should be compared water absorption and aging are also tested
to the allowed limits based on the seat type. The according to FM 1210 standards.
FM class number 1110: stem seal leakage is tested at working pressure
Visibility of the indicator is tested on a 12 meter in partially open position for five minutes, and
distance and by simulating a heavy rainstorm it cycling the disc six times during this time span,
is waterproof tested to make sure that there is no with no visible stem leakage allowed.
collection of water inside.
9
GATE VALVES
Our gate valves are characterized by a unique OS&Y (Outside Screw and Yoke) valves are used The valves are available with ANSI class 150
wedge design with fixed, integral wedge nut in above-ground installations, where the rising drilling as well as PN16 drilling and with stem of
and our own rubber compound that ensures stem design makes it easy to recognize the wedge stainless steel or alu-bronze.
reliable operation and long lifespan. position, open or closed, even at a distance.
The yoke is prepared for installation of a fixed VdS approved gate valves
UL & FM approved gate valves monitoring switch enabling a very fast and easy We offer flanged gate valves and grooved end
AVK offers a wide range of gate valves in a switch installation. NRS (non-rising stem) gate gate valves, both with position indicator showing
slim modern design and resilient seat even up valves can be used for both underground and the wedge position.
to DN600. above ground installation.
11
Gate valves, UL & FM approved
12
Gate valves, UL & FM approved
13
Gate valves, UL & FM approved
14
Gate valves, UL & FM approved
15
Gate valves, UL & FM approved
16
Gate valves, UL & FM approved
17
Gate valves, VdS approved
18
Indicator posts
34/80-001 AVK ref. no. DN Stem length Theoretical Deliv. Gross Price
Post indicator mm mm weight/kg code EUR
Wall type
UL/ULC Listed & FM approved 34-050-80-00010010 (1) 50 250 29 C 2,314.00
Ductile Iron 34-065-80-00010010 (1) 65 250 29 C 2,314.00
Fusion bonded epoxy coating 34-080-80-00010010 (1) 80 250 29 C 2,314.00
in compliance with DIN 3476 34-100-80-00010010 100 250 29 C 2,180.00
part 1 and EN 14901 34-100-80-01010010 100 750 32 C 2,314.00
Clockwise to Close 34-100-80-02010010 100 1250 34 C 2,314.00
34-150-80-00010010 150 250 29 C 2,260.00
34-150-80-01010010 150 750 32 C 2,399.00
34-150-80-02010010 150 1250 34 C 2,399.00
34-200-80-00010010 200 250 29 C 2,314.00
34-200-80-01010010 200 750 32 C 2,399.00
34-200-80-02010010 200 1250 34 C 2,399.00
34-250-80-00010010 250 250 29 C 2,180.00
34-250-80-01010010 250 750 32 C 2,314.00
34-250-80-02010010 250 1250 34 C 2,314.00
34-300-80-00010010 300 250 29 C 2,336.00
34-300-80-01010010 300 750 32 C 2,392.00
34-300-80-02010010 300 1250 34 C 2,392.00
34-350-80-01010010 350 750 32 C 2,328.00
34-350-80-02010010 350 1250 34 C 2,328.00
34-400-80-00000010 (2) 400 250 29 C 2,328.00
34-400-80-00020010 (2) 400 1250 34 C 2,328.00
34-400-80-01010010 (2) 400 750 32 C 2,328.00
(1) Not UL/ULC and FM approved
(2) Only UL/ULC listed
19
Valve accessories
04/F-010 AVK ref. no. DN/DN Pipe cover Theoretical Deliv. Gross Price
Extension spindle for gate mm weight/kg code EUR
valves
Fixed length 04-200-3-50020001 50 - 400 800 1.3 C 216.00
Key adaptor #23-32 04-200-3-55020001 50 - 400 1000 1.3 C 247.00
Stem adaptor #51 04-200-3-60020001 50 - 400 1250 1.3 C 343.00
Polyethylene (PE) 04-200-3-65020001 50 - 400 1500 1.3 C 343.00
04-200-3-75020001 50 - 400 2000 1.3 C 455.00
04-200-3-80020001 50 - 400 3000 1.3 C 699.00
20
Valve accessories
21
UL & FM APPROVED FIRE HYDRANTS
Dry barrel fire hydrants repair at traffic knock down. The fire hydrant’s requirements of AWWA C503 and are rated for a
AVK dry barrel fire hydrants meet or exceed main valve has a ductile iron core which is fully working pressure of 13.7 bar (200 PSI).
AWWA C-502 and are rated for a working encapsulated in EPDM rubber. The nozzle section The shut-off device is directly at the outflow nozzle
pressure of 17.2 bar (250 PSI). They are can be rotated 360 degrees and the upper section for hose or pumper connection which means that
designed for high performance, easy repair of the fire hydrant is repairable under pressure. the fire hydrant is constantly filled with water and
and minimum end user costs for labor and thus under pressure. The fire hydrant is mounted
inventory. The breakable flange and stem Wet barrel fire hydrants directly on the water main, giving full water
rod coupling prevent leaking and enable easy AVK wet barrel fire hydrants meet or exceed the pressure instantaneously when needed.
27/EI-010 AVK ref. no. DN Flange Bury depth Theoretical Deliv. Gross Price
Dry barrel fire hydrant mm drilling mm weight/kg code EUR
Modern type to AWWA C502
UL listed & FM approved 27-EI-U0204-00008-CQ 150 ANSI B16.42 914 154 C 13,990.00
2 x 2.5" NST hose nozzles + 27-EI-U0205-00008-CQ 150 ANSI B16.42 1067 163 C 14,480.00
1 x 4" NST pumper nozzle 27-EI-U0206-00008-CQ 150 ANSI B16.42 1219 172 C 15,899.00
Ductile Iron 27-EI-U0207-00008-CQ 150 ANSI B16.42 1372 181 C 15,873.00
EPDM fire hydrant main valve 27-EI-U0208-00008-CQ 150 ANSI B16.1B 1524 190 C 16,607.00
Fusion bonded epoxy coating 27-EI-U0209-00008-CQ 150 ANSI B16.42 1677 199 C 18,241.00
in compliance with DIN
27-EI-U0210-00008-CQ 150 ANSI B16.42 1829 208 C 18,378.00
3476, GSK approved, with
polyester top coating.
Clockwise to Close
27/JA-100 AVK ref. no. DN Flange Bury depth Theoretical Deliv. Gross Price
Dry barrel fire hydrant mm drilling mm weight/kg code EUR
Modern type to AWWA C502
UL/ULC listed - FM approved 27-JA-O0204-0000J-CP0007 150 ANSI B16.42 914 153 C 11,081.00
Lateral elbow inlet 27-JA-O0205-0000J-CP0007 150 ANSI B16.42 1067 161 C 11,210.00
2 x 2.5" NST hose nozzles + 27-JA-O0206-0000J-CP0007 150 ANSI B16.42 1219 169 C 11,310.00
1 x 4" NST pumper nozzle 27-JA-O0207-0000J-CP0007 150 ANSI B16.42 1372 177 C 11,628.00
Ductile Iron
27-JA-O0208-0000J-CP0007 150 ANSI B16.42 1524 194 C 12,576.00
EPDM fire hydrant main valve
27-JA-O0209-0000J-CP0007 150 ANSI B16.42 1676 202 C 13,494.00
Fusion bonded epoxy coating
27-JA-O0210-0000J-CP0007 150 ANSI B16.42 1829 208 C 13,752.00
in compliance with DIN
3476, GSK approved, with 27-JA-O0211-0000J-CP0007 150 ANSI B16.42 1981 219 C 14,076.00
polyester top coating. 27-JA-O0212-0000J-CP0007 150 ANSI B16.42 2134 224 C 14,292.00
Clockwise to Close
22
Dry barrel fire hydrants, UL & FM approved
27/JA-110 AVK ref. no. DN Flange Bury depth Theoretical Deliv. Gross Price
Dry barrel fire hydrant mm drilling mm weight/kg code EUR
Modern type to AWWA C502
Straight inlet 27-JA-O7205-0000J-CP0007 150 ANSI B16.42 1022 157 C 11,232.00
2 x 2.5" NST hose nozzles +
1 x 4" NST pumper nozzle
Ductile Iron
EPDM fire hydrant main valve
Fusion bonded epoxy coating
in compliance with DIN
3476, GSK approved, with
polyester top coating.
Clockwise to Close
27/RQ-001 AVK ref. no. DN Flange Bury depth Theoretical Deliv. Gross Price
Dry barrel fire hydrant mm drilling mm weight/kg code EUR
Modern type to AWWA C502
Stem rod AISI 316 27-RQ-I0206-0000N-DC0076 150 ANSI B16.42 1219 190 C 15,732.00
2 x 2.5" NST hose nozzles +
1 x 4" NST pumper nozzle
Ductile Iron
EPDM fire hydrant main valve
Fusion bonded epoxy coating
in compliance with DIN
3476, GSK approved, with
polyester top coating.
Clockwise to Close
27/RN-100 AVK ref. no. DN Flange Bury depth Theoretical Deliv. Gross Price
Dry barrel fire hydrant mm drilling mm weight/kg code EUR
Modern type to AWWA C502
Upper/lower stem & bolts in 27-RN-I0206-0000J-DC0006 150 ANSI B16.42 1219 167 A 12,312.00
AISI 316 27-RN-I0207-0000J-DC0006 150 ANSI B16.42 1372 178 C 12,528.00
UL/ULC listed, FM approved 27-RN-I0208-0000J-DC0006 150 ANSI B16.42 1524 194 C 13,392.00
2 x 2.5" NST hose nozzles +
27-RN-I0209-0000J-DC0006 150 ANSI B16.42 1676 202 C 13,644.00
1 x 4" NST pumper nozzle
Ductile Iron
EPDM fire hydrant main valve
Fusion bonded epoxy coating
in compliance with DIN
3476, GSK approved, with
polyester top coating.
Clockwise to Close
23
Hydrant accessories
24
Wet barrel fire hydrants, UL & FM approved
24/10-001
AVK ref. no. DN Product Theoretical Deliv. Gross Price
Wet barrel hydrant with
2 x 2 1/2" NST hose outlets, mm PN Class weight/kg code EUR
1 x 4" or 1 x 4 1/2" NST 24-150-10-00000001 150 CL150 46 C 12,496.00
pumper outlet
(optionally 5" storz outlet)
UL/FM approved
Ductile Iron
EPDM rubber
Epoxy coating / UV-resistant
polyester
Clockwise to Close
25
Butterfly valves, FM approved
26
Swing check valves, UL & FM approved
27
28
FIRE HYDRANTS USED IN WATER SUPPLY
AVK offers a wide range of fire hydrants for above
and underground installation and in a wealth of
variants to meet our customers’ needs.
84/05-003 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model P7 with 2 x hose storz
B 84-080-05-211010 80 PN16 1000 C 8,455.00
Ductile Iron 84-080-05-311010 80 PN16 1250 C 8,687.00
Polyurethane vulcanized plug 84-080-05-411010 80 PN16 1500 C 8,942.00
Fusion bonded epoxy coating 84-100-05-211010 100 PN16 1000 C 9,021.00
to DIN 3476 part 1 and EN 84-100-05-311010 100 PN16 1250 C 9,301.00
14901 externally, enamel to 84-100-05-411010 100 PN16 1500 C 9,810.00
DEV internally
Clockwise to Close
84/16-003 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model P7 with 2 x hose storz
B / 1 x pumper A-storz outlet 84-100-16-211010 100 PN16 1000 C 9,670.00
Ductile Iron 84-100-16-311010 100 PN16 1250 C 10,081.00
Polyurethane vulcanized plug 84-100-16-411010 100 PN16 1500 C 10,286.00
Fusion bonded epoxy coating
to DIN 3476 part 1 and EN
14901 externally, enamel to
DEV internally
Clockwise to Close
84/25-003 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
with drop-down cover
Model P7 - Type C 84-100-25-211013 (1) 100 PN16 1000 C 20,380.00
Ductile Iron 84-100-25-211014 100 PN16 1000 C 20,380.00
Polyurethane vulcanized plug 84-100-25-311013 (1) 100 PN16 1250 C 21,078.00
Fusion bonded epoxy coating 84-100-25-311014 100 PN16 1250 C 21,078.00
to DIN 3476 part 1 and EN 84-100-25-411013 (1) 100 PN16 1500 C 21,566.00
14901 externally, enamel to 84-100-25-411014 100 PN16 1500 C 21,566.00
DEV internally
Clockwise to Close (1) White/red/white reflection tape at drop down cover
29
Above-ground fire hydrants
84/45-003 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
Model P7 "Nostalgia" with 2 x
hose storz B 84-080-45-211011 80 PN16 1000 C 11,451.00
Ductile Iron 84-080-45-211062 (1) 80 PN16 1000 C 12,888.00
Polyurethane vulcanized plug 84-080-45-311011 80 PN16 1250 C 12,134.00
Fusion bonded epoxy coating 84-080-45-311062 (1) 80 PN16 1250 C 13,622.00
to DIN 3476 part 1 and EN 84-080-45-411011 80 PN16 1500 C 12,005.00
14901 externally, enamel to 84-080-45-411062 (1) 80 PN16 1500 C 13,442.00
DEV internally
Clockwise to Close (1) Hydrant body red enamelled outside
84/51-003 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm weight/kg code EUR
model P7 "Nostalgia" with 2 x
hose storz B / 1 x pumper 84-100-51-211011 100 PN16 1000 93 C 10,440.00
nozzle A outlet 84-100-51-211062 (1) 100 PN16 1000 93 C 11,736.00
Ductile Iron 84-100-51-311011 100 PN16 1250 98 C 10,908.00
Polyurethane vulcanized plug 84-100-51-311062 (1) 100 PN16 1250 98 C 12,060.00
Fusion bonded epoxy coating 84-100-51-411062 (1) 100 PN16 1500 105 C 11,304.00
to DIN 3476 part 1 and EN
14901 externally, enamel to (1) Hydrant body red enamelled outside
DEV internally
Clockwise to Close
84/72-003 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model P7 "Niro" with 2 x
hose storz B, 84-080-72-211011 80 PN16 1000 C 14,087.00
Upper barrel of stainless steel 84-080-72-311011 80 PN16 1250 C 14,390.00
Polyurethane vulcanized plug 84-080-72-411011 80 PN16 1500 C 14,693.00
Fusion bonded epoxy coating 84-100-72-211011 100 PN16 1000 C 16,051.00
in compliance with DIN 3476 84-100-72-311011 100 PN16 1250 C 16,884.00
part 1 and EN 14901
84-100-72-411011 100 PN16 1500 C 17,712.00
Clockwise to Close
84/82-003 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model P7 "Niro" with 2 x
hose storz B / 1 x pumper 84-100-82-211011 100 PN16 1000 C 18,361.00
storz A outlet, 84-100-82-311011 100 PN16 1250 C 19,355.00
Upper barrel of stainless steel 84-100-82-411011 100 PN16 1500 C 18,968.00
Polyurethane vulcanized plug
Fusion bonded epoxy coating
in compliance with DIN 3476
part 1 and EN 14901
Clockwise to Close
84/90-001 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model N7 without traffic
break-away design (Type A) 84-080-90-21101010 (1) 80 PN16 1000 C 3,690.00
Single shut-off, 84-080-90-21101015 (2) 80 PN16 1000 C 4,255.00
Upper barrel of stainless steel 84-080-90-31101015 (2) 80 PN16 1250 C 4,459.00
Polyurethane vulcanized plug 84-080-90-41101015 (2) 80 PN16 1500 C 4,454.00
Fusion bonded epoxy coating 84-100-90-21101010 (1) 100 PN16 1000 C 4,688.00
in compliance with DIN 3476
84-100-90-21101012 (3) 100 PN16 1000 C 5,069.00
part 1 and EN 14901
Clockwise to Close 84-100-90-31101010 (1) 100 PN16 1250 C 4,734.00
84-100-90-31101012 (3) 100 PN16 1250 C 5,329.00
84-100-90-41101010 (1) 100 PN16 1500 C 4,879.00
84-100-90-41101012 (3) 100 PN16 1500 C 5,943.00
(1) 2 x coupling B
(2) 2 x coupling C, 1 x coupling B
(3) 2 x coupling B, 1 x coupling A
30
Above-ground fire hydrants
84/91-001 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model N7 with traffic break-
away design (Type C) 84-080-91-21101015 (1) 80 PN16 1000 C 4,575.00
Single shut-off 84-080-91-31101015 (1) 80 PN16 1250 C 4,786.00
Upper barrel of stainless steel 84-080-91-41101010 (2) 80 PN16 1500 C 4,356.00
Polyurethane vulcanized plug 84-080-91-41101015 (1) 80 PN16 1500 C 4,609.00
Fusion bonded epoxy coating 84-100-91-21101010 (2) 100 PN16 1000 C 4,997.00
in compliance with DIN 3476
84-100-91-21101012 (3) 100 PN16 1000 C 5,846.00
part 1 and EN 14901
Clockwise to Close 84-100-91-31101010 (2) 100 PN16 1250 C 6,502.00
84-100-91-31101012 (3) 100 PN16 1250 C 5,978.00
84-100-91-41101010 (2) 100 PN16 1500 C 5,369.00
(1) 2 x coupling C, 1 x coupling B
(2) 2 x coupling B
(3) 2 x coupling B, 1 x coupling A
84/92-001 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model N7 without traffic
break-away design (Type A) 84-080-92-21101015 (1) 80 PN16 1000 C 4,502.00
Double shut-off, 84-080-92-31101010 (2) 80 PN16 1250 C 4,290.00
Upper barrel of stainless steel 84-080-92-31101015 (1) 80 PN16 1250 C 4,545.00
Polyurethane vulcanized plug 84-080-92-41101010 (2) 80 PN16 1500 C 4,288.00
Fusion bonded epoxy coating 84-080-92-41101015 (1) 80 PN16 1500 C 4,541.00
in compliance with DIN 3476
84-100-92-31101010 (2) 100 PN16 1250 C 5,682.00
part 1 and EN 14901
Clockwise to Close 84-100-92-31101012 (3) 100 PN16 1250 C 8,505.00
84-100-92-41101010 (2) 100 PN16 1500 C 5,847.00
(1) 2 x coupling C, 1 x coupling B
(2) 2 x coupling B
(3) 2 x coupling B, 1 x coupling A
84/93-001 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model N7 with traffic break-
away design (Type C) 84-080-93-21101010 (1) 80 PN16 1000 C 5,028.00
Double shut-off, 84-080-93-21101011 (2) 80 PN16 1000 C 5,274.00
Upper barrel of stainless steel 84-080-93-21101015 (3) 80 PN16 1000 C 5,138.00
Ductile Iron 84-080-93-31101010 (1) 80 PN16 1250 C 5,267.00
Polyurethane vulcanized plug 84-080-93-31101015 (3) 80 PN16 1250 C 5,371.00
Fusion bonded epoxy coating 84-080-93-41101010 (1) 80 PN16 1500 C 5,263.00
in compliance with DIN 3476
84-080-93-41101015 (3) 80 PN16 1500 C 5,366.00
part 1 and EN 14901
Clockwise to Close 84-100-93-21101010 (1) 100 PN16 1000 C 5,421.00
84-100-93-31101010 (1) 100 PN16 1250 C 5,438.00
84-100-93-31101012 (4) 100 PN16 1250 C 7,016.00
84-100-93-41101010 (1) 100 PN16 1500 C 5,592.00
84-100-93-41101012 (4) 100 PN16 1500 C 7,224.00
(1) 2 x coupling B
(2) 2 x coupling B, 1 x coupling C
(3) 2 x coupling C, 1 x coupling B
(4) 2 x coupling B, 1 x coupling A
84/93-003 AVK ref. no. DN Product Pipe cover Deliv. Gross Price
Above-ground fire hydrant mm PN Class mm code EUR
model N7 with traffic break-
away design (Type C) 84-080-93-2110101004 80 PN16 1000 C 4,994.00
Double shut-off 84-080-93-3110101004 80 PN16 1250 C 5,123.00
Ductile Iron 84-080-93-4110101004 80 PN16 1500 C 5,078.00
Polyurethane vulcanized plug
Fusion bonded epoxy coating
in compliance with DIN 3476
part 1 and EN 14901
Clockwise to Close
31
Accessories for series 84 above-ground fire hydrants
3002/002-001 AVK ref. no. Communi- Key Theoretical Deliv. Gross Price
VIDI Cap for storz B cation weight/kg code EUR
Smart hydrant cap
3002-002-003-000 LORA TRIANGLE 0.9 C 795.00
Transmits position 3002-002-004-000 LORA OVAL 0.9 C 1,012.00
information (open or closed) 3002-002-008-000 NB-IOT TRIANGLE 0.9 C 795.00
via radio communication 3002-002-009-000 NB-IOT OVAL 0.9 C 795.00
CE-approved
RED-approved
Battery life: 10 years
IP Class 68
32
Above-ground fire hydrants
09/20-001 AVK ref. no. DN Range Product Theoretical Deliv. Gross Price
Above-ground fire hydrant mm mm PN Class weight/kg code EUR
1 x 3” B Storz hose nozzles
Type B 09-080-20-1021 (1) 80 1050 - 1550 PN10 60 C 5,272.00
Aluminum 09-080-20-3021 (2) 80 1050 - 1550 PN10 60 C 5,752.00
Fusion bonded epoxy coating (1)
in compliance with DIN 3476 Automatic drainage
(2) Manual drainage
part 1 and EN 14901
Clockwise to Close
09/30-001 AVK ref. no. DN Range Product Theoretical Deliv. Gross Price
Above-ground fire hydrant mm mm PN Class weight/kg code EUR
1 x 3” B Storz hose nozzles
Type B 09-080-30-1027 (1) 80 1050 - 1550 PN10 75 A 5,964.00
Ductile Iron 09-080-30-102710 (2) 80 1050 - 1550 PN10 75 B 6,423.00
Fusion bonded epoxy coating 09-080-30-3027 (3) 80 1050 - 1550 PN10 75 B 6,423.00
in compliance with DIN 3476 09-080-30-302710 (4) 80 1050 - 1550 PN10 75 A 6,879.00
part 1 and EN 14901
(1) Automatic drainage
Clockwise to Close
(2) Automatic drainage and with additional ball shut off system
(3) Manual drainage
(4) Manual drainage and with additional ball shut off system
09/50-001 AVK ref. no. DN Range Product Theoretical Deliv. Gross Price
Above-ground fire hydrant mm weight/kg code EUR
mm PN Class
1 X 4" / DN 100 Storz hose
nozzle 09-100-50-20 (1) 100 1050 - 1550 PN10 83 B 9,240.00
Type A 09-100-50-30 (2) 100 1050 - 1550 PN10 83 B 9,573.00
Aluminum
(1) Automatic drainage
Fusion bonded epoxy coating
(2) Manual drainage
in compliance with DIN 3476
part 1 and EN 14901
Clockwise to Close
09/90-001 AVK ref. no. DN Range Product Theoretical Deliv. Gross Price
Above-ground fire hydrant mm mm PN Class weight/kg code EUR
2 x 3” B Storz hose nozzles
Automatic drainage 09-100-90-201 100 800 - 1300 PN10 55 A 7,521.00
Aluminum
Fusion bonded epoxy coating
in compliance with DIN 3476
part 1 and EN 14901
Clockwise to Close
33
Underground fire hydrants
29/40-003 AVK ref. no. DN Product Connection Theoretical Deliv. Gross Price
Underground fire hydrant to mm PN Class weight/kg code EUR
EN 1074-6
Ductile Iron 29-100-40-0101 (1) 100 PN16 Bayonet 30 A 1,203.00
EPDM rubber 29-100-40-0102 (2) 100 PN16 3" Storz 30 A 2,510.00
Fusion bonded epoxy coating 29-100-40-0103 (3) 100 PN16 3" NOR 30 A 3,412.00
in compliance with DIN 3476 29-100-40-0104 (4) 100 PN16 4" Storz 30 A 3,457.00
part 1 and EN 14901 29-100-40-0111 (5) 100 PN16 Bayonet - aut. drain 30 B 1,289.00
Clockwise to Close 29-100-40-0112 (6) 100 PN16 3" Storz - aut. drain 30 B 2,596.00
29-100-40-0113 (7) 100 PN16 3" NOR - aut. drain 30 B 3,476.00
29-100-40-0114 (8) 100 PN16 4" Storz - aut. drain 30 B 3,543.00
(1) With bayonet coupling
(2) With 3" stortz coupling
(3) With 3" NOR coupling
(4) With 4" stortz coupling
(5) With bayonet coupling and automatic drain
(6) With 3" stortz coupling and automatic drain
(7) With 3" NOR coupling and automatic drain
(8) With 4" stortz coupling and automatic drain
29/78-007 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Free flow underground fire mm PN Class mm weight/kg code EUR
hydrant
Ductile Iron 29-080-78-1101500096 80 PN16 750 34 C 5,215.00
EPDM rubber 29-080-78-2101500096 80 PN16 1000 35 C 5,368.00
Fusion bonded epoxy coating 29-080-78-3101500096 80 PN16 1250 36 C 5,520.00
in compliance with DIN 3476 29-080-78-4101500096 80 PN16 1500 37 C 5,675.00
part 1 and EN 14901
Clockwise to Close
35/31-004 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Underground fire hydrant to mm PN Class mm weight/kg code EUR
EN 14339
Single shut off 35-080-31-11015 (1) 80 PN16 750 21 C 2,145.00
Ductile Iron 35-080-31-11020 (2) 80 PN16 750 21 C 2,086.00
Polyurethane vulcanized plug 35-080-31-21015 (1) 80 PN16 1000 25 C 2,334.00
Fusion bonded epoxy coating 35-080-31-21020 (2) 80 PN16 1000 25 C 2,284.00
in compliance with DIN 3476 35-080-31-31015 (1) 80 PN16 1250 29 C 2,584.00
part 1 and EN 14901, GSK 35-080-31-31020 (2) 80 PN16 1250 29 C 2,634.00
approved 35-080-31-41015 (1) 80 1500 33 C 3,123.00
PN16
Clockwise to Close 35-080-31-41020 (2) 80 PN16 1500 33 C 3,000.00
(1) Cover with chain
(2) Bayonet coupling and self-closing cover
35/32-003 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Underground fire hydrant w. mm PN Class mm weight/kg code EUR
self closing cover to EN
14339 - Single shut off 35-080-32-11020 80 PN16 750 21 C 2,149.00
Seat stainless steel 35-080-32-21020 80 PN16 1000 25 C 2,267.00
Ductile Iron 35-080-32-31020 80 PN16 1250 29 C 2,571.00
Polyurethane vulcanized plug 35-080-32-41020 80 PN16 1500 33 C 3,099.00
Fusion bonded epoxy coating
in compliance with DIN 3476
part 1 and EN 14901, GSK
approved
Clockwise to Close
34
Underground fire hydrants
35/57-001 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Underground fire hydrant to
mm PN Class mm weight/kg code EUR
EN 14339 and KIWA BRL-
K614-04 35-080-57-11024 80 PN16 750 24 C 1,692.00
Ductile Iron 35-080-57-21024 80 PN16 1000 27 C 2,110.00
Polyurethane vulcanized
plug
Fusion bonded epoxy
coating in compliance with
DIN 3476 part 1 and EN
14901, GSK approved
Clockwise to Close
35/81-010 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Underground fire hydrant to mm PN Class mm weight/kg code EUR
EN 14339
Double shut off 35-080-81-11015 (1) 80 PN16 800 27 C 2,586.00
Ductile Iron 35-080-81-11020 (2) 80 PN16 800 27 C 2,494.00
Polyurethane vulcanized plug 35-080-81-21015 (1) 80 PN16 1000 31 C 2,788.00
Fusion bonded epoxy coating 35-080-81-21020 (2) 80 PN16 1000 31 C 2,788.00
in compliance with DIN 3476 35-080-81-31015 (1) 80 PN16 1250 34 C 3,056.00
part 1 and EN 14901, GSK 35-080-81-31020 (2) 80 PN16 1250 34 C 3,056.00
approved 35-080-81-41015 (1) 80 PN16 1500 38 C 3,424.00
Clockwise to Close 35-080-81-41020 (2) 80 PN16 1500 38 C 3,424.00
(1) Cover with chain
(2) With self-closing lid
35
Underground fire hydrants
35/85-003 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Underground fire hydrant to mm PN Class mm weight/kg code EUR
EN 14339
Double shut off 35-080-85-11008 (1) 80 PN16 800 27 C 2,550.00
Seat stainless steel 35-080-85-11020 (2) 80 PN16 800 27 C 2,550.00
Ductile Iron 35-080-85-21008 (1) 80 PN16 1000 30 C 2,788.00
Polyurethane vulcanized plug 35-080-85-21020 (2) 80 PN16 1000 31 C 2,874.00
Fusion bonded epoxy coating 35-080-85-31008 (1) 80 PN16 1250 34 C 3,056.00
in compliance with DIN 3476 35-080-85-31020 (2) 80 PN16 1250 34 C 3,171.00
part 1 and EN 14901, GSK 35-080-85-41008 (1) 80 1500 38 C 3,466.00
PN16
approved
35-080-85-41020 (2) 80 PN16 1500 38 C 3,466.00
Clockwise to Close
(1) Storz B coupling
(2) Bayonet coupling and self-closing cover
35/85-004 AVK ref. no. DN Product Pipe cover Theoretical Deliv. Gross Price
Underground fire hydrant to mm PN Class mm weight/kg code EUR
EN 14339 w. ball chamber
90° 35-080-85-16034 80 PN16 550 24 C 4,149.00
Double shut off 35-080-85-26034 80 PN16 750 29 C 4,501.00
Seat in stainless steel 35-080-85-36034 80 PN16 1000 33 C 4,915.00
Ductile Iron 35-080-85-46034 80 PN16 1250 37 C 5,385.00
Polyurethane vulcanized plug
Fusion bonded epoxy coating
in compliance with DIN 3476
part 1 and EN 14901, GSK
approved
Clockwise to Close
36
Hydrant accessories
37
Fountain posts
38
TERMS AND CONDITIONS
OF SALE AND DELIVERY
1. Applicability regulation, alteration of duties, significant Products per week or fraction thereof up to a
These general terms and conditions of sale and increase in the cost of labour, materials or other maximum of five (5.0%) percent of the invoiced
delivery (“Conditions”) shall govern the current cost of manufacture or transportation) that value of the delayed Products. Liquidated
and future supply and delivery of products and gives the Supplier a disadvantage compared damages as set out in this clause 5 shall be the
services (“Products”) from AVK International A/S to the circumstances prevailing at the date of only remedies available to the Purchaser in the
(“Supplier”) and purchased by the purchaser the acceptance of the Binding Order. Any such event of a delay in delivery or non-delivery.
(“Purchaser”), unless otherwise agreed in increase of price shall reflect the actual increased
writing. The applicability of any general and cost level as evidenced by the Supplier’s records. 6. Cancellation and Return
special terms and conditions of the Purchaser A Binding Order can only be cancelled by
shall be excluded. 4. Terms of Payment written agreement between the Supplier and
The Supplier shall be entitled to invoice the the Purchaser. The Supplier shall be entitled
2. Quotations and Orders Purchaser for the price of the Products on, or to charge the Purchaser with all costs that the
The Supplier’s quotations of Products and pricing at any time after, the scheduled delivery of the Supplier may incur as a result of the Purchaser
shall be subject to change. Products. The time of payment of the price of the cancelling an order. Returns cannot be accepted
Products is of the essence. The Purchaser shall more than 6 months after delivery.
Contracts for delivery shall be accepted upon pay the invoice for the Products within 30 days
(i) written quotation by the Supplier accepted of the date of the invoice from the Supplier. If The Purchaser cannot expect to receive payment
by the Purchaser in accordance with the terms the Purchaser fails to make full payment on the of more than 70% of the purchase price of the
of the quotation and subsequently confirmed by due date, then, without prejudice to any other Products returned. All returns must show the
the Supplier in writing (ii) written confirmation right or remedy available to the Supplier, the original invoice number, the date of delivery and
by the Supplier of the Purchaser’s order (each a Supplier shall be entitled to (i) charge interest on be in a good sellable condition.
“Binding Order”). A modification of a Binding the amount unpaid, at a rate of, at present, 1,00
Order shall be in writing. % per month or fraction thereof (interest will be Return of special Products, Products which have
added monthly) and (ii) charge a fee of EUR 20 been specially manufactured for the Purchaser or
3. Prices per payment reminder. standard Products which have been changed to
All prices quoted by the Supplier shall be valid meet the Purchaser’s specifications, shall not be
for 30 days only. The price of the Products shall In the event of any payment default by the accepted.
be the price quoted by the Supplier or, where Purchaser, the Supplier shall be entitled
no price has been quoted (or the quoted price is to postpone the delivery and to store any 7. Packaging
no longer valid), the price listed in the Supplier’s undelivered Products at the expense of the Packaging may not be returned. Packaging which
pricelist applicable at the date of acceptance. Purchaser by use of a freight forwarding agency has been charged separately may be returned
All prices shall be quoted by the Supplier on or by utilizing the storage facilities of the Supplier no later than three (3) months after the time of
an ex works basis (EXW – INCOTERMS 2020) until payment of due invoices. delivery but only upon written agreement.
unless otherwise agreed in writing. The costs of
packaging will be charged to the Purchaser in 5. Delivery 8. Defects
addition to the price of the Products. The prices Delivery shall take place EX WORKS (INCOTERMS The Purchaser shall be solely responsible for
are exclusive of any import duties, VAT, levies, 2020). Prior to dispatch, the Purchaser shall give satisfying itself that the Products shall be suitable
taxes and other charges which may be imposed the Supplier information regarding VAT number and/or fit for the particular purpose for which
on the Products. Any typographical, clerical of the Purchaser. Upon receipt of the Products, they have been ordered.
or other error or omission in any quotation, the Purchaser shall issue to the Supplier a notice
pricelist, acceptance offer, or other document acknowledging the receipt of the Products and Products shall be deemed defective only when
or information issued by the Supplier may be return required export statements. The Supplier the Purchaser is able to prove that the Products
corrected by the Supplier without any liability on shall be entitled to make partial deliveries. If the are not in conformity with the Binding Order. At
the part of the Supplier. Purchaser fails to take delivery, the Supplier shall any rate, Defective Products shall be deemed not
be entitled to store any undelivered Products to include any non-conformity caused by
The Supplier reserves the right by giving notice at the expense of the Purchaser, i.e., by use of
to the Purchaser at any time prior to dispatch a freight forwarding agency or by utilizing the (i) the use of a Product for an
to increase the price of the Products to reflect storage facilities of the Supplier. In the event application for which it has not been
any substantial increase in the cost of the of late delivery attributable to the Supplier, the designed or which has not been
Supplier, which is due to factors beyond the Purchaser may seek liquidated damages for recommended by the Supplier;
control of the Supplier (including, but not limited delay equal to zero-point five (0.5%) percent of (ii) any change by the Purchaser of
to, any foreign exchange fluctuation, currency the price of the invoiced value of the delayed the chemical composition of the
Copyright©AVK Group A/S 2023
TERMS AND CONDITIONS
OF SALE AND DELIVERY
medium or treatment of the medium 9. Retention of Title shall be limited to the amount of the
for which the Products has been used; Notwithstanding delivery and the passing of purchase price of the Products
(iii) installation which is not in accordance the risk involved in the Products, or any other payable under the relevant Binding
with the Supplier’s installation provision of these Conditions, the ownership of Order; and
instructions (if any) and accepted the Products shall not pass to the Purchaser (iii) reasonable costs for access and
codes of good practice; until the Supplier has received in cash or cleared restoration, transport of a defect free
(iv) lack of or faulty maintenance; and funds payment in full of any amount due. Until product to the site of installation,
(v) normal wear and tear. such time as the ownership of the Products dismantling and reinstallation at the
passes to the Purchaser, the Purchaser shall hold site of installation of the defective
The Purchaser shall carry out a reasonable the Products as the Supplier’s fiduciary agent Product to a maximum of EUR five
inspection of the Products within five (5) working and bailee and shall keep the Products separate million a year (5,000,000).
days following the receipt of the Products, from those of the Purchaser and third parties
ascertaining that no transport damage has and properly stored, protected and insured In no event shall the Supplier be liable to the
occurred, and shall notify the Supplier in the and identified as the property of the Supplier. Purchaser or to any third party for loss of profits,
event of transport damage. Until that time, the Purchaser shall be entitled loss of revenue, loss of business opportunity, loss
to re-sell or use the Products in the ordinary of time or for any indirect, incidental, special,
All other defects shall, to the extent possible, course of its business but shall account to the consequential, punitive or exemplary damages
be notified to the Supplier within fifteen (15) Supplier for the proceeds of sale or otherwise arising out of or related to the delivery of any
working days from detection, by defining the the Products, whether tangible or intangible, Products.
defect and declaring the claims to be asserted including insurance proceeds, and shall keep
(the “Notification Period”). In any event, the all such proceeds separate from any monies or The limitation of liability set out above in this
Purchaser shall lose the right to rely on a lack property of the Purchaser and third parties and, clause 10 shall not apply:
of conformity of the Products if the Purchaser in the event of tangible proceeds, properly stored,
does not give notice thereof to the Supplier protected and insured. (i) in the event of claims for
within a period of (i) two (2) years from the date compensation as a result of death or
of installation at the latest or (ii) three (3) years Until such time as the ownership to the Products bodily injury;
(collectively the “Cut-Off Date”) from the date passes to the Purchaser (and provided the (ii) in the event of liability according to
on which the Products were delivered (whichever Products are still in existence and have not mandatory law;
occurs first). In respect of electronic Products, been re-sold), the Supplier shall be entitled, at (iii) in the event of wilful intent or gross
incl. VIDI Products, the Purchaser shall notify any time, to require the Purchaser to deliver the negligence on the part of the Supplier;
the Supplier of any non-conformity no later Products to the Supplier and, if the Purchaser and
than two (2) years from the date of delivery, or fails to do so, forthwith to enter upon any (iv) for reasonable costs in the event of
the Purchaser shall no longer have the right to premises of the Purchaser or any third party an infringement of intellectual property
make any claim against the Supplier (the “Short where the Products are stored and re-possess rights related to the Supplier’s
Cut-Off Date”). The Purchaser may, at the the Products. performance; except infringement
Purchaser’s discretion, demand the Supplier to or violation arising from or based
repair or replace the non-conforming Products. 10. Liability upon the Supplier’s compliance with
The Supplier shall cover direct costs for access Notwithstanding anything to the contrary in particular requirements of the
and restoration, transport of a defect-free these Conditions, for any and all claims, losses, Purchaser that differ from the
product to the site of installation, dismantling costs and damages whether such are based on Supplier’s standard specifications for
and reinstallation at the site of installation of indemnification, contract negligence, breach of the Products.
the defective Products. In the event of repair or contract, breach of warranty, statutory rules or
replacement by the Supplier, the Cut-Off Date otherwise and to the fullest extent permitted by 11. Force Majeure
and/or the Short Cut-Off Date period shall run applicable law, the liability of the Supplier shall be The Supplier shall not be liable for any delay or
from the time when the Products were first limited to: failure of performance due to strikes, lockouts,
actually delivered, and not from the time of repair fires, floods, act of governmental authority,
or replacement. No other remedies shall be (i) in respect of property damage, the epidemics, pandemics, terrorism, political
available to the Purchaser in the event of a lack yearly limit shall be EUR 5 million instability within the country in which the Supplier
of conformity of the Products. (5,000,000); and operates, acts of God or other causes beyond
(ii) in respect of any other liability, the the Supplier’s reasonable control provided that
total aggregate liability of the Supplier the Supplier has given notice to the Purchaser
01-02-2024
© 2024 AVK GROUP A/S - rev. 2