Data sheet 6DL1134-6TH00-0PH1

SIMATIC ET 200SP HA, analog HART input module, AI 16XI 2-wire HART HA,
suitable for terminal block H1, M1, color code CC01, channel diagnostics, 16-bit,
+/-0.1%,

General information
Product type designation AI 16 x I 2-wire mA HART
Firmware version V1.1
● FW update possible Yes
Usable terminal block TB type H1, M1, P0 and N0
Color code for module-specific color identification plate CC01
Product function
● I&M data Yes; I&M0 to I&M3
Engineering with
● PCS 7 configurable/integrated from version V9.0
Redundancy
● Redundancy capability Yes; With TB type M1
CiR - Configuration in RUN
Reparameterization possible in RUN Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption (rated value) 80 mA; without sensor supply
Current consumption, max. 90 mA; without sensor supply
Encoder supply
24 V encoder supply
● 24 V Yes
● Short-circuit protection Yes; Electronic (response threshold 0.7 A to 1.5 A)
● Output current per channel, max. 0.5 A
● Output current per module, max. 2A
Power loss
Power loss, typ. 4.5 W; without sensor supply
Address area
Address space per module
● Address space per module, max. 34 byte; 32-byte inputs and 2 bytes for QI information
● Address space per module with HART, max. 74 byte; 32-byte inputs and 2 bytes for QI information, 40-byte inputs for HART
● Address space per module with MultiHART, max. 41 byte; 32-byte inputs for HART and 2 bytes for QI information, 6-byte inputs
for HART, and 1-byte output for MultiHART command
Analog inputs
Number of analog inputs 16
permissible input current for current input (destruction limit), 30 mA
max.

6DL11346TH000PH1 Subject to change without notice


10/23/2023
Page 1/3 © Copyright Siemens
Input ranges (rated values), currents
● 0 to 20 mA Yes; 16 bit incl. sign
— Input resistance (0 to 20 mA) 250 Ω
● 4 mA to 20 mA Yes; 16 bit incl. sign
— Input resistance (4 mA to 20 mA) 250 Ω
Cable length
● shielded, max. 800 m; with unshielded cables up to 800 m, remember that (external) EMC
loads can cause incorrect measured values
Analog value generation for the inputs
Measurement principle integrating (Sigma-Delta)
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit; 15 bit at 0 ... 10 mA and 60 Hz interference suppression
● Integration time, parameterizable Yes; channel by channel
Smoothing of measured values
● parameterizable Yes; none, weak, medium, strong, channel-by-channel
Encoder
Connection of signal encoders
● for current measurement as 2-wire transducer Yes
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.01 %
Temperature error (relative to input range), (+/-) 0.005 %/K
Crosstalk between the inputs, min. 60 dB
Repeat accuracy in steady state at 25 °C (relative to input 0.05 %
range), (+/-)
Operational error limit in overall temperature range
● Current, relative to input range, (+/-) 0.5 %
Basic error limit (operational limit at 25 °C)
● Current, relative to input range, (+/-) 0.1 %
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
● Limit value alarm Yes; two upper and two lower limit values in each case
Diagnoses
● Monitoring the supply voltage Yes
● Wire-break Yes; channel by channel
● Short-circuit Yes; Channel-by-channel, short-circuit of the encoder supply to ground or of an
input to the encoder supply
● Overflow/underflow Yes; channel by channel
Diagnostics indication LED
● MAINT LED Yes; Yellow LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; green LED
● for channel diagnostics Yes; red LED
● for module diagnostics Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels No
● between the channels and backplane bus Yes
● Between the channels and load voltage L+ No
Isolation
Isolation tested with 1 500 V DC/1 min, type test
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -40 °C
● horizontal installation, max. 70 °C; Observe derating
● vertical installation, min. -40 °C
● vertical installation, max. 60 °C; Observe derating
Dimensions
Width 22.5 mm
Height 115 mm

6DL11346TH000PH1 Subject to change without notice


10/23/2023
Page 2/3 © Copyright Siemens
Depth 138 mm
Weights
Weight, approx. 148 g

last modified: 8/11/2023

6DL11346TH000PH1 Subject to change without notice


10/23/2023
Page 3/3 © Copyright Siemens