Rope Pear Socket User Manual
Rope Pear Socket User Manual
user manual
rope pear socket
Table of contents
5 INSTALLATION ...........................................................................................................................................................................11
6 MAINTENANCE ...........................................................................................................................................................................14
7 REJECTION .................................................................................................................................................................................16
Disclaimer
Copyright
No part of this manual may be reproduced, transmitted, stored in any retrieval system or translated into any language, without the prior
written permission of NEMAG B.V. The products and trademarks are protected by copyright ©, various trademarks ® and patents.
Changes
All possible care has been taken in the preparation of this manual. All information, illustrations and specifications are based on the latest
information available at the time of publication. NEMAG B.V. reserves the right to make changes without notice to both this manual
(including dimension tables) and to the products that are described in this manual.
Product warranty
Any warranties, expressed or implied, concerning the use of Rope Pear Sockets and Quick Release Links apply to new, unused
products when tested in a standard testing machine under controlled conditions, in direct tension, and at a uniform rate of speed. The
term “Breaking load” contains no implication of what load a Rope Pear Socket and Quick Release Link will withstand if not properly
used, or if it suffers abuse. All equipment using Rope Pear Sockets and Quick Release Links must be properly maintained. Rope Pear
Sockets and Quick Release Links must be properly stored, handled, used and maintained within the rules of user manual. Most
importantly, Rope Pear Sockets and Quick Release Links must be regularly inspected before and during each use. Inspections must
meet local or applicable national safety regulations. Damage, abuse, overloading or improper maintenance can cause failure and
accidents. If in doubt about the safe and proper use of Rope Pear Sockets and Quick Release Links consult manufacturer.
1.2 Conventions
1.2.1 Language
The original text of the manual is written in US English. Any translation is a derivative of the original text.
1.2.2 Illustrations
The illustrations in the manual are a typical example of the delivered product. Essential differences in configuration between
product types are indicated in the text.
1.2.3 Units
All data in this manual is given in accordance with metrical European units and standards.
1.3 Admonitions
DANGER
Indicates a hazard with a high level of risk which, if not avoided or if the instruction is executed incorrectly, will cause death,
serious personal injury, or damage to the product.
WARNING
Indicates a hazard with a medium level of risk which, if not avoided or if the instruction is executed incorrectly, can cause
death, serious personal injury, or damage to the product.
CAUTION
Indicates a hazard with a low level of risk which, if not avoided or if the instruction is executed incorrectly, can cause minor
personal injury, or damage to the product.
NOTE
Indicates important information for correct use of the product.
2.1 Markings
The following information is given on the NEMAG Rope Pear Socket:
A. Batch code
B. Size
C. NEMAG logo
The figures for batch code and size in the illustration are an example.
• The NEMAG Rope Pear Socket and any associated equipment must be used, maintained and stored in accordance with this
manual, the manual(s) of the associated equipment, and the applicable local legislation.
• The NEMAG Rope Pear Socket must be inspected before and during each use, as described in this manual, and in accordance
with the applicable local legislation.
• Do not subject the NEMAG Rope Pear Socket to temperatures that are higher than 350° C.
• Do not subject the NEMAG Rope Pear Socket to temperatures that are higher than 300° C for more than 100 hours.
• Do not use the NEMAG Rope Pear Socket if it has become highly magnetic.
• Do not install a steel wire rope with a diameter that differs from the specifications in section 3.1.
• Do not use the NEMAG Rope Pear Socket if the number of undergone load cycles is more than 250,000 loads at SWL.
• Do not use the NEMAG Rope Pear Socket if it has been overloaded by more than 200%.
• Do not use the NEMAG Rope Pear Socket if it is permanently deformed or seriously damaged.
• Do not weld or heat-treat the NEMAG Rope Pear Socket.
• Reject and destroy the NEMAG Rope Pear Socket if any of the conditions in chapter 7.
When you are in doubt about the safe and correct use of the NEMAG Rope Pear Socket, refer to NEMAG B.V.
NOTE
The working load is the recommended maximum load for grabbing operations when NEMAG Quick Release Links and
NEMAG Rope Pear Sockets pass over a wide ‘U’ cable sheave. For other applications, you must adhere to a safety factor that
is in line with official local and international directives.
NOTE
The breaking strength of the NEMAG Rope Pear Socket is equal or higher than the breaking strength of the average
applicable steel wire rope in that size of socket (based on the construction 6x36WS with steel core with a tensile strength of
1960 N/mm2).
For the NEMAG Rope Pear Socket type S, the breaking strength is related to special steel wire ropes with a smaller diameter
that have a higher breaking load, like 8-strand wire ropes.
NOTE
The force transmitting parts of the NEMAG Quick Release Link are made of material in accordance with the specifications laid
down in standard EN 1677-1 Components for slings – Forged steel components – Grade 8.
Given:
• Steel wire rope with a diameter of 26 mm
• Safe working load of the steel wire rope: 10,000 kg
1. According to section 3.1, select NEMAG Rope Pear Socket no. 1026
2. Then, according section 3.1, and the table below, NEMAG Quick Release Link no.10 is possible
size 4 5 6 7 8 9 10 11 12 13 14 15 17
2
3
4
5
6
7
8
9
10
11
NEMAG Rope Pear Socket
12
13
14
15
17
type s
924
1026
1130
1232
1336
1440
3221
1548
1648
Connection possible
Connection not possible
NOTE
Wide ‘U’ cable sheaves generally have the dimensions as shown in the table above. In case of different dimensions, refer to
NEMAG B.V.
NOTE
Diameter C has been designed for a NEMAG Quick Release Link that is one size larger than the NEMAG Rope Pear Socket
that is indicated in the table.
Radius E depends on the diameter of the applied steel wire rope.
4.1 Overview
A. Bow
B. Level cam for casting material
C. Body
D. Outer end
NEMAG Rope Pear Sockets are cast from austenitic manganese steel, which
combines a high toughness and a high resistance to wear. The NEMAG Rope Pear
Socket generally lasts longer than the steel wire rope itself.
The figures for batch code and size in the illustration are an example.
The standard NEMAG Rope Pear Socket is designed for installation and use with
common steel wire ropes.
The NEMAG Rope Pear Socket type S is especially designed for installation and
use with high strength / compacted steel wire ropes.
The NEMAG Rope Pear Socket is an end connection for steel wire ropes. The NEMAG Rope Pear Socket ensures a strong
connection with other steel wire ropes, chains or appliances, especially in combination with the NEMAG Quick Release Link.
• Assembly of 1 outer end of a steel wire rope fitted with a NEMAG Rope Pear
Socket (A) and 1 piece of equipment that is fitted with a fixed eye (C), connected
with a NEMAG Quick Release Link (B).
• Assembly of 2 outer ends of steel wire ropes fitted with NEMAG Rope Pear
Sockets (A, C), connected with a NEMAG Quick Release Link (B). This
combination is suitable to pass over a special rope sheave, called a wide 'U'
sheave. See also section 3.
The general method for installation is the same for both casting materials. Refer to the table at the end of this procedure for the
required volume of casting material.
NOTE
Refer to the instructions that come with the casting material and to the supplier of the steel wire rope for specific information
about the use of the casting material.
1. Make sure that the conical case inside the NEMAG Rope Pear socket is free of
any paint and grease.
2. Place the NEMAG Rope Pear Socket over the steel wire rope.
3. Carefully tie up the wire rope over a length of at least 2 times diameter (D) of
the steel wire rope. Start at a distance (L) from the top of the steel wire rope.
Distance L is to be found on next page table.
4. Untwine all strands so that the end of the steel wire rope looks like a broom.
5. Thoroughly clean the broom. Remove any grease with a (branded) degreaser
or with an ultrasonic cleaning agent. Keep the broom in a downward position
while you clean it to prevent that liquid comes into the steel wire rope. Let the
cleaned end of the steel wire rope dry.
a. First pour a little bit of resin from above into the NEMAG Rope Pear
Socket until some first resin leaks out of the underside of the body of the
NEMAG Rope Pear Socket. This to make sure that the underside of the
body is completely filled with resin.
b. Close the underside of the NEMAG Rope Pear Socket at the end of the
wire rope with a flexible sealant. This prevents further leakage of casting
resin.
8. If you use metallic casting mass: Close the underside of the NEMAG Rope
Pear Socket before you pour in the casting mass.
9. Pour the resin or casting mass from above into the NEMAG Rope Pear
Socket, up to the level cam. Also refer to the instructions that come with the
casting material.
NEMAG Rope Pear Socket Steel wire rope L Required volume of casting material
size diameter (mm) (mm) cubic centimetre (cc)
4 16-17 58 70
5 18-19 64 85
6 20-21 74 125
7 22-24 78 150
8 25-27 90 175
9 28-30 98 195
10 31-33 110 200
11 34-36 110 400
12 37-39 130 400
13 40-42 132 700
14 43-45 155 700
15 46-48 170 700
NEMAG Rope Pear Socket Steel wire rope L Required volume of casting material
NOTE
The indicated volume of casting material for each size of the NEMAG Rope Pear Socket is an indication and is subject to
change.
6.1 Lubrication
• Grease the contact areas (A). This extends the lifetime of both the NEMAG
Quick Release Link and the NEMAG Rope Pear Socket.
• Use EP3 or EP4 grease (lubricant for high-pressure contact surfaces).
• Apply grease after every 24 hours of use.
NOTE
Do not grease the NEMAG Rope Pear Socket when it is used in an environment with large quantities of abrasive particles. For
example during transshipment of alumina or other abrasive / dusty ores.
6.2 Cleaning
During use, particles that stimulate wear can become embedded in the lubricant. Therefore, regularly clean the bow of the NEMAG
Rope Pear Socket.
Criterion: Number of cycles at Safe Grab operation General purpose and container operation
Work Load (SWL)
60 cycles / hour 60 cycles / hour
1,6 load cycle during one grab cycle. 1 load cycle during one operation cycle.
Inspection after 125,000 cycles at SWL 125,000 cycles at SWL
Do not use after 250,000 cycles at SWL 250,000 cycles at SWL
Criterion: Hours of operation Grab operation General purpose and container operation
Inspection after 1300 hours of operation 2000 hours of operation
Do not use after 2600 hours of operation 4000 hours of operation
Criterion: Shifts of operation Grab operation General purpose and container operation
24 hours per day operation Inspection after 8 weeks Inspection after 12 weeks
Do not use after 16 weeks Do not use after 24 weeks
16 hours per day operation Inspection after 12 weeks Inspection after 18 weeks
Do not use after 24 weeks Do not use after 36 weeks
8 hours per day operation Inspection after 24 weeks Inspection after 36 weeks
Do not use after 48 weeks Do not use after 72 weeks
• Heating in excess of 300° C has taken place for more than 100 hours.
• The number of undergone load cycles is more than 250,000 loads at SWL.
8.2 Storage
The minimum requirement for storage is protection against humidity. Check the conservation every 3 months if storage takes place
in very humid conditions. If necessary, correct the conservation.