Inteligen 1000 3.1.0 Datasheet
Inteligen 1000 3.1.0 Datasheet
1000
| InteliGen 1000 3.1.0 Datasheet | Related HW ver: 1.1.0.0 | Related SW ver: 3.1.0 | Date of issue: 4/30/2024
Terminals and dimensions
RTC battery Replaceable, type CR1632 3V Pulse input Bin 9 and 10 max. 50 Hz
E-Stop Weight
Dedicated terminal for safe Emergency Stop input.
Controller 750 g
Physically disconnects BO 1 & BO 2 from power supply.
Package 920 g
Controller handles 300 million records into the History, which represents
roughly 1 record per second during 9,5 years. Shall be the History recording
faster, the controller lifetime will become smaller.
CM-4G-GPS An easy-to-use and highly efficient solution for connecting the controllers online via 4G network. CM24GGPSXBX
CM-RS232-485 Communication module enabling integration of the controller into the local monitoring system CM223248XBX
*EM-BIO8-EFCP Binary I/O plug-in module with 8 binary inputs or outputs. EM2BIO8EXBX
Note: *EFCP is already included on the CU as aux current measurement, EFCP on BIO8 module is not available.
InteliVision 5.2 5" TFT external display with 800x480 px resolution RD2IV5BXBAA
InteliVision 10Touch 10.1" Touchscreen display uni with 1280 x 800 px resolution RD1IV10TBPF
InteliVision 13Touch 13.3" Marine certified display unit with 1920 × 1080 px resolution RD1IV13TBME
InteliVision 18 18.5" Touchscreen display unit with 1366 × 768 px resolution RD31840PBIE
CAN Repeater Module, compatible when using 32C/8C CAN Intercontroller Comm
I-CR I-CR
Mode
Communication gateway with configurable interfaces between Modbus TCP/RTU,
InteliGateway 300 ComAp CAN, WebSupervisor and InteliScada protocols allowing user-defined CM2GW300BAB
interconnection of all attached devices
ANSI
Description ANSI code Description ANSI code Description
code
Master unit 1 Reverse power 32R Power factor 55
Stopping device 5 Master sequence device 34 Overvoltage 59
Multi-function device 11 Undercurrent 37 Pressure switch 63
Overspeed 12 Excitation loss 40 Liquid level switch 71
E-mail: [email protected]
Web: www.comap-control.com
© ComAp. Features and specification are subject to change without prior notice.
Underspeed 14 Unit sequence starting 44 Alarm relay * 74
Speed and frequency matching
15 Current unbalance 46 Vector shift 78
device
16EFT
Data communications device Voltage unbalance 47 Reclosing relay 79
16SC
Starting-to-running transition
19 Incomplete sequence relay 48 Overfrequency 81H
contractor
Synchronizing-check 25 Temperature monitoring 49T Underfrequency 81U
Thermal relay 26 Overcurrent 50/50TD ROCOF 81R
Undervoltage 27 Earth fault current 50N+64 Auto selective control/transfer 83
Annunciator 30 Overcurrent IDMT 51 Regulating device 90
Overload 32 Earth fault current IDMT 51+64
EN 60255-1 g)
2
EN 60529 (IP20) EN 60068-2-27 (a=500 m/s ; T=6 ms)
Grid codes
European Requirements for Generators, 2016/631
E-mail: [email protected]
Web: www.comap-control.com
© ComAp. Features and specification are subject to change without prior notice.