INTRODUCTION
PETRA’s fan coil units (RAC Series) are The units cover an air flow range from 200 They provide flexible operation and
ideally designed for air conditioning to 1200 nominal CFM. The standard unit control of indoor conditions in individual
residential, commercial and institutional consists of a coil section, suitable for both spaces.
buildings with low static pressure chilled / hot water, a fan section with a
application. direct drive centrifugal fan and a flat filter.
NOMENCLATURE
UNIT TYPES
CB GFC PFC
Ceiling Basic model (Galvanized Steel) Floor Cabinet Model (Galvanized Steel) Floor Cabinet Model (Deluxe)
Designed for concealed ceiling installation Is designed for floor mounted exposed Designed for floor mounted exposed
above false ceiling with ducted supply air applications. The unit has a decorative applications, the unit has a decorative
distribution and free return of air above painted galvanized steel cabinet that painted plastic and galvanized steel
false ceiling. Units of this type consist of a Encloses all the unit’s components. Units cabinet. Units of this type consist of a fan
coil and fan without a return plenum or of this type consist of a fan, coil and flat coil and flat filter, and are supplied
filter. filter, and are supplied with fixed (steel manually operated double deflection grills
panel) lancing grill for the supply air. for the supply air and fixed deflection
plastic grills for the return air.
CBP
Ceiling Basic with Plenum (Galvanized
Steel) GCC
Ceiling Cabinet Model (Galvanized Steel) PCC
is designed for concealed ceiling
installation above the false ceiling with These units have same specifications as Ceiling Cabinet Model (Deluxe)
ducted supply and return air distribution. the GFC model, but are used for ceiling These units have the same specifications
The plenum encloses the fan section of suspended exposed applications. as the PFC plastic cover model, but are
the basic unit. Units of this type consist of used for ceiling suspended exposed
a coil, fan and a flat filter. applications.
FB
Floor Basic Model (Galvanized Steel)
Units have the same specifications as the
GFC model but without a cabinet. Units
are provided with galvanized steel
plenum without paint, consist of a fan,
coil and filter and are used for concealed
floor applications.
1
RAC
OUTSTANDING FEATURES
— Low sound level units, NC as — Coil can be on the left or right without — Coil is supplied with 2-air vents piped to
low as NC 30. affecting coil performance. (Except PFC the drain pan.
— Low height and small footprint & PCC coil that can only be on the right) — Heavy gauge sheet metal casing with
G90 - galvanized steel.
QUALITY ASSURANCE
— Units are manufactured in an ISO — Units are manufactured in an ISO — Units are rated in accordance with the
9001-2000 certified facility. 14001-2004 certified facility. ARI 440 standard.
SPECIFICATIONS
Coils Motors Casing
All coils are constructed of 3/8 inch Motors are driven by permanent split All units are constructed of heavy gauge
diameter copper tubes mechanically capacitor electric motors and are of the galvanized steel without paint except for
expanded into aluminum fins. The coil fins three speed type (with internal thermal cabinet models which are coated with
are spaced at 12 fins per inch for 3 protection). weatherproof, polyester powder,
rows,10 fins per inch for 4 rows or 12 fins electrostatic paint, oven-baked to ensure
per inch for 1 row. All coils are leak tested maximum gloss and hardness.
at 450 Psig air pressure and are suitable Filters
for up to 350 Psig working pressure with a All models are provided with 1” thick
manual air vent, piped to the drain pan. (nominal) and 7/8” thick actual frame size Insulation
with 5/8” thick aluminum media flat filter for All units are internally lined with 0.5 inch
(CBP+GCC), 1/2’’ thick filter for (GFC+FB) fiber-glass insulation for the coil and fan
Fans and a washable filter for (PFC+PCC). section.
All units are provided with forward curved
centrifugal fans of the double inlet type
that are designed for maximum efficiency Drain Pan
and uniform air distribution. The fans are All units are provided with a drain pan
statically and dynamically balanced to connection from one side. The drain pan is
ensure quiet operation and optimal insulated on its underside to prevent
performance. All fans are of the direct condensation.
drive type.
OPTIONS
The following options can be
provided:
— Manual 3-speed switch - (Wall — 3-way valve - Loose or built in unit. — Double skin construction with 1.0” fiber
Mounted), can be built-in PFC & GFC — Built-in electric heaters with the glass isolation for CBP models only.
models following standard features: Inner skin can be either solid or
— Thermostat (including 3-speed switch) - 1. Finned tube electric heating elements. perforated.
(Wall Mounted), Can be built in PFC & 2. Automatic thermal safety cutout. — Stainless steel drain pan.
GFC models — Optional components for built-in electric
— Shut-off valve - Loose item OR built in heaters are available:
unit. 1. Manual thermal safety cutout. (Not
— Auxiliary drain pan under 3-way valves. applicable for GCC & GFC models)
— 4-Pipe system units - double coil 2. Contactor (one normally open
— Synthetic media filter. contactor).
— Unit’s casing for none decorative units — All heaters are single stage.
are coated with weatherproof, polyester — All heaters are available in either 220-
powder, electrostatic paint, oven-baked 240V 1-phase 50/60Hz power supply.
to ensure maximum gloss and — Electric heater capacities are provided
hardness. in this manual.
2
RAC
GENERAL DATA TABLES
CB+CBP
MODEL RAC 2 3 4 5 6 8 10 12
Power supply Volt/Phase/Hz 220-240 / 1/ 50 or 60Hz and 110 / 1/ 50 Hz
Control voltage Volt/Hz 220-240 / 50or 60Hz and 110/ 60 Hz
Unit Casing Heavy gauge, galvanized steel,
GCC + GFC
MODEL RAC 2 3 4 5 6 8 10 12
Power supply Volt/Phase/Hz 220-240 / 1/ 50 or 60Hz and 110 / 1/ 50 Hz
Control voltage Volt/Hz 220-240 / 50or 60Hz and 110/ 60 Hz
Unit Casing Heavy gauge, galvanized steel, with oven-baked weatherproof, powder electrostatic paint
Insulation 0.5 thick fiber glass or equivalent
Coil Copper tubes, Aluminum fins
Fins per inch 10 or 12
No. of rows For cooling 3 or 4
For heating 1,3 or 4
2
Total face area Ft 1.39 1.39 1.39 1.94 1.94 2.26 3.17 3.17
Tube diameter Inch 3/8
Fan Forward curved DWDI centrifugal
No. 1 1 2 2 2 2 4 4
Type of drive Direct driven
Total air flow (Nominal) CFM 200 300 400 500 600 800 1000 1200
Fan motor Split capacitor (Three speed)
No. 1 1 1 1 1 1 2 2
Nominal motor rating HP 1/20 1/20 1/15 1/15 1/15 1/15 1/15 1/15
Coil Connection Inch 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4
Drain connection size Inch Copper 7/8 sweat
Air filter For CBP models only
Type Aluminum mesh flat filter
Thickness Inch 1
Operating weight Lb
Ceiling cabinet with Plenum GCC 104 104 106 126 126 141 194 194
Floor cabinet with Plenum GFC 82 52 93 110 110 128 172 172
*12 Fins per inch for 1-row coils.
*12 Fins per inch for 3-row coils.
*10 Fins per inch for 4-row coils.
3
RAC
GENERAL DATA TABLES
PCC + PFC
MODEL RAC 2 3 4 5 6 8 10 12
Power supply Volt/Phase/Hz 220-240 / 1/ 50 or 60Hz and 110 / 1/ 50 Hz
Control voltage Volt/Hz 220-240 / 50or 60Hz and 110/ 60 Hz
Unit Casing Decorative painted plastic and galvanized steel cabinet
Insulation 3.2mm thick fiber glass or equivalent
Coil Copper tubes, Aluminum fins
Fins per inch 10 or 12
No. Of rows For cooling 3 or 4
For heating 1,3 or 4
2
Total face area Ft 1.11 1.11 1.33 1.33 1.89 2.11 2.89 2.89
Tube diameter Inch 3/8
Fan Forward curved DWDI centrifugal fans
No. 1 1 2 2 2 2 4 4
Type of drive Direct driven
Total air flow (Nominal) 200 300 400 500 600 800 1000 1200
Fan motor Split capacitor (Three speed)
No. 1 1 1 1 1 1 2 2
Nominal motor rating HP 1/20 1/15 1/15 1/15 1/15 1/15 1/15
Coil Connection Inch 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4
Drain connection size Inch Copper 5/8 sweat
Air filter
Type Washable
Operating weight Lb
Floor cabinet PFC 88 88 95 95 117 117 157 157
Ceiling cabinet PCC 88 88 95 95 117 117 157 157
FB
MODEL RAC 2 3 4 5 6 8 10 12
Power supply Volt/Phase/Hz 220-240 / 1/ 50 or 60Hz and 110 / 1/ 50 Hz
Control voltage Volt/Hz 220-240 / 50or 60Hz and 110/ 60 Hz
Unit Casing Heavy gauge, galvanized steel, with oven-baked weatherproof, powder electrostatic paint
Insulation 0.5 thick fiber glass or equivalent
Coil Copper tubes, Aluminum fins
Fins per inch 10 or 12
No. of rows For cooling 3 or 4
For heating 1,3 or 4
2
Total face area Ft 1.39 1.39 1.39 1.85 1.85 2.26 3.17 3.17
Tube diameter Inch 3/8
Fan Forward curved DWDI centrifugal fans
No. 1 1 2 2 2 2 4 4
Type of drive Direct driven
Total air flow (Nominal) CFM 200 300 400 500 600 800 1000 1200
Fan motor Split capacitor (Three speed)
No. 1 1 1 1 1 1 2 2
Nominal motor rating HP 1/20 1/20 1/15 1/15 1/15 1/15 1/15 1/15
Coil Connection Inch 1/2 1/2 1/2 1/2 3/4 3/4 3/4
Drain connection size Inch Copper 5/8 sweat
Air filter
Type Aluminum mesh flat filter
Thickness Inch 1/2
Operating weight Lb
Floor Basic FB 63.9 63.9 75.0 75.0 88.2 108.0 156.5 183.0
*12 Fins per inch for 1-row coils.
*12 Fins per inch for 3-row coils.
*10 Fins per inch for 4-row coils.
4
RAC
PERFORMANCE DATA TABLES
CB/CBP (3-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 8789 6779 1.76 1.78 10365 6719 2.07 2.42 12086 6690 2.42 3.23
78 8840 7337 1.77 1.80 10420 7282 2.08 2.45 12207 7283 2.44 3.29
H 283
80 9021 7953 1.80 1.87 10578 7885 2.12 2.52 12296 7858 2.46 3.33
85 9346 9346 1.87 2.00 10814 9337 2.16 2.62 12447 9266 2.49 3.41
76 7328 5578 1.47 1.27 8651 5554 1.73 1.73 9966 5503 1.99 2.25
78 7381 6037 1.48 1.29 8665 6000 1.73 1.73 9928 5923 1.99 2.23
CB\CBP 2 M 221
80 7428 6491 1.49 1.30 8684 6440 1.74 1.74 10086 6425 2.02 2.30
85 7688 7687 1.54 1.39 8854 7602 1.77 1.80 10334 7619 2.07 2.41
76 5588 4203 1.12 0.77 6633 4220 1.33 1.05 7630 4192 1.53 1.37
78 5782 4608 1.16 0.82 6679 4561 1.34 1.07 7716 4551 1.54 1.40
L 158
80 5799 4942 1.16 0.82 6680 4882 1.34 1.07 7690 4865 1.54 1.39
85 5905 5793 1.18 0.85 6910 5791 1.38 1.14 7867 5746 1.57 1.45
76 10055 7806 2.01 2.29 11876 7732 2.38 3.12 13872 7685 2.77 4.18
78 10196 8491 2.04 2.35 12064 8436 2.41 3.22 14018 8376 2.80 4.26
H 340
80 10238 9134 2.05 2.37 12160 9104 2.43 3.27 14102 9038 2.82 4.31
85 10685 10685 2.14 2.56 12420 10772 2.48 3.40 14445 10744 2.89 4.51
76 8789 6779 1.76 1.78 10365 6719 2.07 2.42 12086 6690 2.42 3.23
78 8840 7337 1.77 1.80 10420 7282 2.08 2.45 12207 7283 2.44 3.29
CB\CBP 3 M 283
80 9021 7953 1.80 1.87 10578 7885 2.12 2.52 12296 7858 2.46 3.33
85 9346 9346 1.87 2.00 10814 9337 2.16 2.62 12447 9266 2.49 3.41
76 7328 5578 1.47 1.27 8651 5554 1.73 1.73 9966 5503 1.99 2.25
78 7381 6037 1.48 1.29 8665 6000 1.73 1.73 9928 5923 1.99 2.23
L 221
80 7428 6491 1.49 1.30 8684 6440 1.74 1.74 10086 6425 2.02 2.30
85 7688 7687 1.54 1.39 8854 7602 1.77 1.80 10334 7619 2.07 2.41
76 11852 9206 2.37 3.11 14026 9125 2.81 4.27 16361 9046 3.27 5.70
78 11971 10006 2.39 3.17 14187 9930 2.84 4.36 16543 9867 3.31 5.82
H 422
80 12140 10815 2.43 3.26 14373 10746 2.88 4.47 16725 10682 3.35 5.94
85 12764 12764 2.55 3.58 14769 12764 2.95 4.70 17045 12674 3.41 6.16
76 10454 8124 2.09 2.46 12353 8039 2.47 3.36 14435 7999 2.89 4.50
78 10546 8810 2.11 2.50 12490 8751 2.50 3.43 14589 8711 2.92 4.59
CB\CBP 4 M 358
80 10717 9536 2.14 2.58 12587 9448 2.52 3.48 14747 9432 2.95 4.69
85 11206 11206 2.24 2.80 12961 11229 2.59 3.68 14993 11163 3.00 4.84
76 8631 6658 1.73 1.72 10145 6586 2.03 2.33 11830 6556 2.37 3.10
L 277 78 8770 7240 1.75 1.77 10287 7177 2.06 2.39 11954 7138 2.39 3.16
80 8856 7810 1.77 1.80 10336 7728 2.07 2.41 12072 7714 2.41 3.22
85 9172 9172 1.83 1.93 10614 9167 2.12 2.53 12217 9101 2.44 3.29
76 16712 12500 3.34 6.82 19577 12393 3.92 9.16 22700 12347 4.54 12.07
78 16807 13492 3.36 6.89 19727 13420 3.95 9.29 22877 13387 4.58 12.25
H 533
80 17052 14562 3.41 7.08 19949 14474 3.99 9.48 23018 14406 4.60 12.39
85 17389 17096 3.48 7.34 20327 17044 4.07 9.82 23446 16988 4.69 12.82
76 14307 10725 2.86 5.11 16902 10715 3.38 6.96 19518 10650 3.90 9.11
78 14481 11626 2.90 5.22 17001 11580 3.40 7.04 19699 11550 3.94 9.26
CB\CBP 5 M 441
80 14628 12516 2.93 5.32 17086 12442 3.42 7.10 19887 12452 3.98 9.43
85 14914 14706 2.98 5.52 17420 14645 3.48 7.37 20067 14600 4.01 9.59
76 12744 9506 2.55 4.12 14923 9451 2.99 5.52 17222 9402 3.44 7.21
L 377 78 12848 10271 2.57 4.18 15100 10250 3.02 5.64 17367 10188 3.47 7.32
80 12904 11019 2.58 4.21 15146 10998 3.03 5.68 17494 10968 3.50 7.42
85 13140 12935 2.63 4.36 15406 12922 3.08 5.86 17700 12872 3.54 7.59
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
5
RAC
PERFORMANCE DATA TABLES
CB/CBP (3-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 18180 13645 3.64 7.98 21502 13597 4.30 10.91 24879 13508 4.98 14.33
78 18485 14826 3.70 8.23 21763 14772 4.35 11.16 25136 14673 5.03 14.61
H 601
80 18618 15940 3.72 8.34 21890 15876 4.38 11.28 25408 15845 5.08 14.90
85 19168 18812 3.83 8.80 22371 18724 4.47 11.75 25818 18659 5.16 15.36
76 16712 12500 3.34 6.82 19577 12393 3.92 9.16 22700 12347 4.54 12.07
78 16807 13492 3.36 6.89 19727 13420 3.95 9.29 22877 13387 4.58 12.25
CB\CBP 6 M 533
80 17052 14562 3.41 7.08 19949 14474 3.99 9.48 23018 14406 4.60 12.39
85 17389 17096 3.48 7.34 20327 17044 4.07 9.82 23446 16988 4.69 12.82
76 14307 10725 2.86 5.11 16902 10715 3.38 6.96 19518 10650 3.90 9.11
78 14481 11626 2.90 5.22 17001 11580 3.40 7.04 19699 11550 3.94 9.26
L 441
80 14628 12516 2.93 5.32 17086 12442 3.42 7.10 19887 12452 3.98 9.43
85 14914 14706 2.98 5.52 17420 14645 3.48 7.37 20067 14600 4.01 9.59
76 21698 16046 4.34 11.88 25447 15956 5.09 15.98 29514 15922 5.90 21.07
78 21923 17369 4.39 12.11 25722 17302 5.14 16.31 29796 17260 5.96 21.45
H 693
80 22168 18677 4.43 12.36 25984 18630 5.20 16.62 29940 18550 5.99 21.65
85 22695 21958 4.54 12.92 26503 21901 5.30 17.24 30519 21844 6.10 22.43
76 19372 14346 3.87 9.62 22711 14279 4.54 12.93 26269 14220 5.25 16.96
78 19647 15560 3.93 9.88 22904 15452 4.58 13.14 26441 15388 5.29 17.17
CB\CBP 8 M 600
80 19737 16685 3.95 9.96 23130 16637 4.63 13.38 26630 16557 5.33 17.40
85 20162 19581 4.03 10.36 23515 19528 4.70 13.80 27155 19507 5.43 18.04
76 16918 12510 3.38 7.48 19738 12431 3.95 9.96 22890 12422 4.58 13.12
78 17091 13529 3.42 7.63 20017 13496 4.00 10.23 22992 13407 4.60 13.23
L 503
80 17239 14539 3.45 7.75 20094 14473 4.02 10.30 23146 14423 4.63 13.40
85 17430 16980 3.49 7.91 20430 16986 4.09 10.62 23493 16930 4.70 13.77
76 32691 23933 6.54 15.43 38259 23834 7.65 20.67 44236 23766 8.85 27.10
78 33040 25875 6.61 15.74 38617 25771 7.72 21.04 44541 25709 8.91 27.45
H 1009
80 33380 27814 6.68 16.04 38963 27734 7.79 21.39 44828 27618 8.97 27.78
85 34132 32620 6.83 16.72 39720 32538 7.94 22.17 45591 32440 9.12 28.66
76 29012 21287 5.80 12.36 33881 21185 6.78 16.49 39220 21157 7.84 21.65
78 29247 22992 5.85 12.55 34268 22945 6.85 16.84 39522 22880 7.90 21.96
CB\CBP 10 M 869
80 29575 24736 5.92 12.81 34478 24634 6.90 17.03 39737 24580 7.95 22.19
85 30060 28919 6.01 13.20 35063 28882 7.01 17.58 40315 28821 8.06 22.79
76 25382 18607 5.08 9.65 29634 18540 5.93 12.86 34228 18498 6.85 16.81
78 25597 20092 5.12 9.80 29863 20024 5.97 13.04 34348 19953 6.87 16.92
L 733
80 25720 21534 5.14 9.89 30084 21505 6.02 13.22 34607 21452 6.92 17.15
85 26194 25222 5.24 10.23 30557 25188 6.11 13.61 35094 25136 7.02 17.61
76 36370 26709 7.27 18.81 42726 26634 8.55 25.40 49477 26551 9.90 33.39
78 36858 28939 7.37 19.29 43120 28811 8.62 25.84 49824 28722 9.97 33.83
H 1165
80 37145 31078 7.43 19.57 43532 31016 8.71 26.30 50160 30903 10.03 34.26
85 38012 36483 7.60 20.43 44372 36405 8.87 27.25 51078 36327 10.22 35.44
76 32691 23933 6.54 15.43 38259 23834 7.65 20.67 44236 23766 8.85 27.10
78 33040 25875 6.61 15.74 38617 25771 7.72 21.04 44541 25709 8.91 27.45
CB\CBP 12 M 1009
80 33380 27814 6.68 16.04 38963 27734 7.79 21.39 44828 27618 8.97 27.78
85 34132 32620 6.83 16.72 39720 32538 7.94 22.17 45591 32440 9.12 28.66
76 29012 21287 5.80 12.36 33881 21185 6.78 16.49 39220 21157 7.84 21.65
78 29247 22992 5.85 12.55 34268 22945 6.85 16.84 39522 22880 7.90 21.96
L 869
80 29575 24736 5.92 12.81 34478 24634 6.90 17.03 39737 24580 7.95 22.19
85 30060 28919 6.01 13.20 35063 28882 7.01 17.58 40315 28821 8.06 22.79
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
6
RAC
PERFORMANCE DATA TABLES
CB/CBP (4-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 9493 7177 1.90 2.51 11245 7179 2.25 3.43 12930 7113 2.59 4.45
78 9537 7751 1.91 2.53 11186 7708 2.24 3.40 13105 7743 2.62 4.56
H 280
80 9718 8384 1.94 2.62 11357 8337 2.27 3.50 13141 8313 2.63 4.58
85 9781 9781 1.96 2.65 11483 9776 2.30 3.57 13232 9743 2.65 4.64
76 7811 5844 1.56 1.75 9197 5839 1.84 2.37 10580 5805 2.12 3.07
78 7938 6343 1.59 1.81 9308 6331 1.86 2.42 10679 6293 2.14 3.12
CB\CBP 2 M 218
80 7948 6792 1.59 1.81 9284 6769 1.86 2.41 10767 6779 2.15 3.17
85 8098 7968 1.62 1.87 9494 7974 1.90 2.51 10878 7937 2.18 3.23
76 5998 4412 1.20 1.08 6950 4385 1.39 1.41 8033 4390 1.61 1.85
78 6138 4804 1.23 1.12 7094 4775 1.42 1.47 8129 4762 1.63 1.89
L 156
80 6131 5126 1.23 1.12 7073 5094 1.42 1.46 8085 5069 1.62 1.87
85 6326 6033 1.27 1.19 7218 5975 1.44 1.52 8223 5950 1.65 1.93
76 10937 8314 2.19 3.26 12886 8269 2.58 4.42 14991 8248 3.00 5.85
78 11007 8992 2.20 3.30 13025 8977 2.61 4.51 15049 8918 3.01 5.89
H 336
80 11030 9655 2.21 3.31 13038 9634 2.61 4.52 15141 9611 3.03 5.96
85 11330 11330 2.27 3.48 13301 11364 2.66 4.69 15373 11334 3.08 6.13
76 9493 7177 1.90 2.51 11245 7179 2.25 3.43 12930 7113 2.59 4.45
78 9537 7751 1.91 2.53 11186 7708 2.24 3.40 13105 7743 2.62 4.56
CB\CBP 3 M 280
80 9718 8384 1.94 2.62 11357 8337 2.27 3.50 13141 8313 2.63 4.58
85 9781 9781 1.96 2.65 11483 9776 2.30 3.57 13232 9743 2.65 4.64
76 7811 5844 1.56 1.75 9197 5839 1.84 2.37 10580 5805 2.12 3.07
78 7938 6343 1.59 1.81 9308 6331 1.86 2.42 10679 6293 2.14 3.12
L 218
80 7948 6792 1.59 1.81 9284 6769 1.86 2.41 10767 6779 2.15 3.17
85 8098 7968 1.62 1.87 9494 7974 1.90 2.51 10878 7937 2.18 3.23
76 12871 9836 2.57 4.41 15235 9791 3.05 6.03 17766 9758 3.55 8.02
78 13017 10669 2.60 4.50 15376 10624 3.08 6.13 17944 10612 3.59 8.17
H 416
80 13138 11495 2.63 4.58 15432 11424 3.09 6.17 17890 11362 3.58 8.12
85 13353 13353 2.67 4.72 15699 13464 3.14 6.37 18176 13419 3.64 8.37
76 11440 8687 2.29 3.55 13475 8640 2.70 4.80 15625 8599 3.13 6.32
78 11518 9404 2.30 3.59 13561 9351 2.71 4.86 15741 9323 3.15 6.40
CB\CBP 4 M 354
80 11544 10089 2.31 3.61 13645 10073 2.73 4.91 15844 10050 3.17 6.48
85 11875 11875 2.38 3.80 13744 11807 2.75 4.98 15983 11800 3.20 6.59
76 9320 7044 1.86 2.43 11039 7044 2.21 3.32 12693 6983 2.54 4.30
78 9518 7675 1.90 2.52 11169 7649 2.23 3.39 12862 7601 2.57 4.40
L 274
80 9538 8228 1.91 2.53 11147 8186 2.23 3.38 12896 8160 2.58 4.43
85 9599 9599 1.92 2.56 11268 9598 2.25 3.45 12984 9558 2.60 4.48
76 17784 13200 3.56 9.35 20862 13151 4.17 12.55 24062 13087 4.81 16.34
78 17898 14249 3.58 9.46 21029 14221 4.21 12.74 24231 14166 4.85 16.55
H 527
80 18009 15296 3.60 9.57 21062 15243 4.21 12.78 24327 15203 4.87 16.67
85 18191 17878 3.64 9.75 21282 17839 4.26 13.02 24548 17802 4.91 16.95
76 15334 11339 3.07 7.12 17971 11314 3.59 9.53 20581 11218 4.12 12.24
78 15396 12222 3.08 7.17 17964 12160 3.59 9.53 20844 12180 4.17 12.53
CB\CBP 5 M 436
80 15454 13095 3.09 7.22 18092 13073 3.62 9.65 20905 13066 4.18 12.60
85 15702 15343 3.14 7.43 18288 15288 3.66 9.85 20991 15236 4.20 12.70
76 13506 9965 2.70 5.64 15828 9952 3.17 7.54 18290 9951 3.66 9.85
78 13590 10741 2.72 5.70 15917 10736 3.18 7.62 18329 10710 3.67 9.89
L 373
80 13700 11557 2.74 5.78 15988 11508 3.20 7.69 18359 11468 3.67 9.92
85 13832 13456 2.77 5.89 16150 13442 3.23 7.83 18542 13417 3.71 10.10
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
7
RAC
PERFORMANCE DATA TABLES
CB/CBP (4-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 19552 14517 3.91 11.14 22907 14444 4.58 14.92 26502 14388 5.30 19.54
78 19555 15621 3.91 11.14 22997 15587 4.60 15.03 26634 15555 5.33 19.71
H 594
80 19716 16797 3.94 11.31 23214 16784 4.64 15.29 26730 16697 5.35 19.85
85 20006 19676 4.00 11.62 23380 19616 4.68 15.49 26940 19552 5.39 20.14
76 17784 13200 3.56 9.35 20862 13151 4.17 12.55 24062 13087 4.81 16.34
78 17898 14249 3.58 9.46 21029 14221 4.21 12.74 24231 14166 4.85 16.55
CB\CBP 6 M 527
80 18009 15296 3.60 9.57 21062 15243 4.21 12.78 24327 15203 4.87 16.67
85 18191 17878 3.64 9.75 21282 17839 4.26 13.02 24548 17802 4.91 16.95
76 15334 11339 3.07 7.12 17971 11314 3.59 9.53 20581 11218 4.12 12.24
78 15396 12222 3.08 7.17 17964 12160 3.59 9.53 20844 12180 4.17 12.53
L 436
80 15454 13095 3.09 7.22 18092 13073 3.62 9.65 20905 13066 4.18 12.60
85 15702 15343 3.14 7.43 18288 15288 3.66 9.85 20991 15236 4.20 12.70
76 22916 16903 4.58 16.08 26850 16831 5.37 21.53 31050 16797 6.21 28.15
78 23164 18279 4.63 16.40 27069 18207 5.41 21.85 31295 18182 6.26 28.56
H 684
80 23239 19588 4.65 16.50 27193 19535 5.44 22.04 31389 19496 6.28 28.72
85 23548 22892 4.71 16.90 27550 22875 5.51 22.57 31650 22791 6.33 29.16
76 20449 15074 4.09 13.04 24047 15071 4.81 17.57 27701 15018 5.54 22.80
78 20648 16322 4.13 13.27 24116 16233 4.82 17.66 27806 16194 5.56 22.96
CB\CBP 8 M 593
80 20688 17444 4.14 13.32 24324 17460 4.87 17.94 28006 17409 5.60 23.27
85 20996 20408 4.20 13.69 24523 20384 4.91 18.22 28249 20349 5.65 23.64
76 17810 13085 3.56 10.12 20830 13052 4.17 13.49 23878 12970 4.78 17.34
78 17941 14121 3.59 10.25 20974 14096 4.20 13.66 24113 14050 4.82 17.66
L 497
80 18055 15148 3.61 10.37 21098 15120 4.22 13.81 24178 15062 4.84 17.75
85 18213 17653 3.64 10.54 21285 17647 4.26 14.04 24404 17593 4.88 18.05
76 34405 25163 6.88 20.67 40177 25062 8.04 27.51 46361 25009 9.27 35.82
78 34519 27085 6.90 20.80 40365 27024 8.07 27.75 46611 27004 9.32 36.18
H 997
80 34733 29042 6.95 21.04 40590 29004 8.12 28.03 46717 28927 9.34 36.33
85 35077 33506 7.02 21.42 40977 33850 8.20 28.53 47173 33806 9.44 36.99
76 30513 22312 6.10 16.58 35610 22230 7.12 22.03 40985 22172 8.20 28.54
78 30644 24023 6.13 16.71 35750 23946 7.15 22.19 41181 23905 8.24 28.79
CB\CBP 10 M 858
80 30730 25701 6.15 16.80 35951 25700 7.19 22.42 41352 25648 8.27 29.01
85 31175 30036 6.24 17.25 36289 29968 7.26 22.81 41688 29928 8.34 29.44
76 26638 19421 5.33 12.92 31054 19381 6.21 17.12 35781 19357 7.16 22.22
78 26714 20889 5.34 12.99 31232 20889 6.25 17.30 35872 20836 7.17 22.33
L 724
80 26928 22411 5.39 13.18 31249 22322 6.25 17.32 35942 22300 7.19 22.41
85 27194 26105 5.44 13.42 31508 26011 6.30 17.59 36261 26018 7.25 22.77
76 38367 28131 7.67 25.27 44917 28047 8.98 33.79 51988 28020 10.40 44.26
78 38573 30344 7.72 25.52 45268 30303 9.05 34.28 52215 30226 10.44 44.61
H 1151
80 38837 32574 7.77 25.84 45442 32482 9.09 34.52 52396 32431 10.48 44.90
85 39365 38053 7.87 26.49 45970 37989 9.19 35.26 52876 37907 10.58 45.66
76 34405 25163 6.88 20.67 40177 25062 8.04 27.51 46361 25009 9.27 35.82
78 34519 27085 6.90 20.80 40365 27024 8.07 27.75 46611 27004 9.32 36.18
CB\CBP 12 M 997
80 34733 29042 6.95 21.04 40590 29004 8.12 28.03 46717 28927 9.34 36.33
85 35077 33506 7.02 21.42 40977 33850 8.20 28.53 47173 33806 9.44 36.99
76 30513 22312 6.10 16.58 35610 22230 7.12 22.03 40985 22172 8.20 28.54
78 30644 24023 6.13 16.71 35750 23946 7.15 22.19 41181 23905 8.24 28.79
L 858
80 30730 25701 6.15 16.80 35951 25700 7.19 22.42 41352 25648 8.27 29.01
85 31175 30036 6.24 17.25 36289 29968 7.26 22.81 41688 29928 8.34 29.44
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
8
RAC
PERFORMANCE DATA TABLES (CB/CBP)
(3-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 283 16512 3.30 4.87 14812 1.48 1.09 13012 0.87 0.40 11048 0.55 0.18
CB\CBP 2 M 221 12965 2.59 3.09 12014 1.20 0.74 10672 0.71 0.28 9139 0.46 0.12
L 158 9698 1.94 1.80 9198 0.92 0.45 8133 0.54 0.17 7036 0.35 0.08
H 340 18975 3.80 6.33 17206 1.72 1.44 15043 1.00 0.53 12504 0.63 0.22
CB\CBP 3 M 283 16512 3.30 4.87 14812 1.48 1.09 13012 0.87 0.40 11048 0.55 0.18
L 221 12965 2.59 3.09 12014 1.20 0.74 10672 0.71 0.28 9139 0.46 0.12
H 422 22759 4.55 8.92 20440 2.04 1.98 17755 1.18 0.72 14733 0.74 0.30
CB\CBP 4 M 358 19928 3.99 6.94 17858 1.79 1.54 15684 1.05 0.57 13037 0.65 0.24
L 277 16242 3.25 4.72 14498 1.45 1.04 12736 0.85 0.39 10814 0.54 0.17
H 554 30839 6.17 18.01 28275 2.83 4.20 25071 1.67 1.58 21547 1.08 0.70
CB\CBP 5 M 470 26820 5.36 13.86 24532 2.45 3.22 22085 1.47 1.25 19095 0.96 0.56
L 377 22064 4.41 9.62 20441 2.04 2.30 18478 1.23 0.90 16080 0.80 0.41
H 601 33455 6.69 20.98 29979 3.00 4.68 26851 1.79 1.80 22854 1.14 0.79
CB\CBP 6 M 533 29670 5.93 16.75 27204 2.72 3.91 24429 1.63 1.51 20884 1.04 0.67
L 441 25617 5.12 12.72 23273 2.33 2.92 20978 1.40 1.14 18172 0.91 0.52
H 693 38526 7.71 29.15 35119 3.51 6.74 31612 2.11 2.62 27404 1.37 1.18
CB\CBP 8 M 600 33831 6.77 22.86 31144 3.11 5.39 28194 1.88 2.12 24551 1.23 0.97
L 503 29557 5.91 17.76 26981 2.70 4.13 24509 1.63 1.64 21454 1.07 0.76
H 1036 57594 11.52 37.28 53250 5.33 8.86 47858 3.19 3.43 42166 2.11 1.60
CB\CBP 10 M 907 51297 10.26 30.02 47734 4.77 7.23 43341 2.89 2.86 38161 1.91 1.33
L 733 42764 8.55 21.38 39902 3.99 5.19 36510 2.43 2.09 32377 1.62 0.99
H 1165 63418 12.68 44.64 58533 5.85 10.56 52806 3.52 4.12 46069 2.30 1.88
CB\CBP 12 M 1009 56239 11.25 35.66 52081 5.21 8.50 47194 3.15 3.35 41359 2.07 1.55
L 869 49703 9.94 28.31 46049 4.61 6.77 41902 2.79 2.69 36939 1.85 1.26
(4-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 280 16604 3.32 5.94 15627 1.56 1.47 14007 0.93 0.57 12226 0.61 0.26
CB\CBP 2 M 218 13220 2.64 3.89 12602 1.26 0.99 11410 0.76 0.39 10023 0.50 0.18
L 156 9784 1.96 2.23 9235 0.92 0.56 8751 0.58 0.24 7669 0.38 0.11
H 336 19892 3.98 8.32 17975 1.80 1.91 16226 1.08 0.75 14088 0.70 0.34
CB\CBP 3 M 280 16604 3.32 5.94 15627 1.56 1.47 14007 0.93 0.57 12226 0.61 0.26
L 218 13220 2.64 3.89 12602 1.26 0.99 11410 0.76 0.39 10023 0.50 0.18
H 416 23378 4.68 11.23 21473 2.15 2.65 19187 1.28 1.02 16541 0.83 0.46
CB\CBP 4 M 354 20707 4.14 8.96 18887 1.89 2.09 16942 1.13 0.81 14690 0.73 0.37
L 274 16232 3.25 5.70 15292 1.53 1.42 13707 0.91 0.55 12123 0.61 0.26
H 548 31749 6.35 22.94 29237 2.92 5.48 26701 1.78 2.20 23691 1.19 1.05
CB\CBP 5 M 464 27168 5.43 17.19 25829 2.58 4.36 23414 1.56 1.73 20730 1.04 0.82
L 373 22541 4.51 12.17 21183 2.12 3.03 19469 1.30 1.24 17419 0.87 0.60
H 594 33714 6.74 25.65 31347 3.14 6.23 28599 1.91 2.50 25164 1.26 1.17
CB\CBP 6 M 527 30826 6.17 21.72 28345 2.84 5.17 25983 1.73 2.10 22935 1.15 0.99
L 436 25803 5.16 15.63 24270 2.43 3.89 22253 1.48 1.58 19731 0.99 0.75
H 684 39141 7.83 36.30 36493 3.65 8.89 33328 2.22 3.58 29768 1.49 1.72
CB\CBP 8 M 593 35146 7.03 29.74 32324 3.23 7.11 29751 1.98 2.91 26579 1.33 1.40
L 497 29544 5.91 21.58 27809 2.78 5.40 25797 1.72 2.24 22923 1.15 1.07
H 1023 59081 11.82 47.12 55097 5.51 11.55 50807 3.39 4.74 45482 2.27 2.29
CB\CBP 10 M 896 52249 10.45 37.54 49811 4.98 9.60 45666 3.04 3.90 41002 2.05 1.90
L 724 43325 8.67 26.57 41102 4.11 6.75 38156 2.54 2.81 34492 1.73 1.39
H 1151 64911 12.98 56.08 60742 6.07 13.82 55833 3.72 5.63 49759 2.49 2.70
CB\CBP 12 M 997 57955 11.59 45.47 53913 5.39 11.10 49660 3.31 4.54 44471 2.22 2.20
L 858 50272 10.05 34.96 47699 4.77 8.87 43977 2.93 3.64 39511 1.98 1.77
(1-Row heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 295 8479 1.696 0.773 6375 0.637 0.114 4360 0.291 0.025 2587 0.129 0.005
CB\CBP 2 M 230 7200 1.440 0.561 5349 0.535 0.081 3806 0.254 0.019 2346 0.117 0.004
L 165 5688 1.138 0.353 4433 0.443 0.056 3154 0.210 0.013 2024 0.101 0.003
H 354 9606 1.921 0.987 7191 0.719 0.144 4814 0.321 0.030 2763 0.138 0.006
CB\CBP 3 M 295 8479 1.696 0.773 6375 0.637 0.114 4360 0.291 0.025 2587 0.129 0.005
L 230 7200 1.440 0.561 5349 0.535 0.081 3806 0.254 0.019 2346 0.117 0.004
H 439 10992 2.198 1.286 8063 0.806 0.181 5396 0.360 0.038 3003 0.150 0.007
CB\CBP 4 M 373 9947 1.989 1.057 7278 0.728 0.148 4978 0.332 0.032 2893 0.145 0.007
L 289 8374 1.675 0.754 6253 0.625 0.110 4310 0.287 0.024 2582 0.129 0.005
H 577 15812 3.162 2.856 12323 1.232 0.457 9147 0.610 0.117 6167 0.308 0.032
CB\CBP 5 M 488 14064 2.813 2.272 11108 1.111 0.373 8299 0.553 0.097 5613 0.281 0.027
L 392 12142 2.428 1.706 9701 0.970 0.287 7238 0.483 0.075 5037 0.252 0.022
H 625 16537 3.307 3.118 12953 1.295 0.503 9571 0.638 0.128 6376 0.319 0.034
CB\CBP 6 M 555 15306 3.061 2.680 11991 1.199 0.433 8945 0.596 0.113 5956 0.298 0.030
L 459 13595 2.719 2.127 10651 1.065 0.344 8003 0.534 0.091 5432 0.272 0.025
H 721 19601 3.920 4.531 15642 1.564 0.762 11929 0.795 0.207 8379 0.419 0.061
CB\CBP 8 M 624 17802 3.560 3.756 14374 1.437 0.647 10955 0.730 0.176 7679 0.384 0.052
L 524 15913 3.183 3.019 12817 1.282 0.519 9925 0.662 0.146 7035 0.352 0.044
H 1079 30088 6.018 6.188 24451 2.445 1.083 19074 1.272 0.308 13822 0.691 0.096
CB\CBP 10 M 945 27547 5.509 5.213 22651 2.265 0.934 17626 1.175 0.265 12819 0.641 0.084
L 763 23846 4.769 3.940 19615 1.961 0.708 15497 1.033 0.207 11410 0.571 0.067
H 1212 32410 6.482 7.151 26276 2.628 1.244 20444 1.363 0.352 14755 0.738 0.109
CB\CBP 12 M 1050 29470 5.894 5.943 24032 2.403 1.047 18834 1.256 0.301 13667 0.683 0.094
L 904 26751 5.350 4.924 21884 2.188 0.874 17188 1.146 0.253 12534 0.627 0.080
9
RAC
PERFORMANCE DATA TABLES
FB (3-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 8816 6795 1.76 1.80 10365 6723 2.07 2.43 12086 6693 2.42 3.24
78 8959 7391 1.79 1.85 10450 7302 2.09 2.47 12207 7286 2.44 3.30
H 283
80 9047 7970 1.81 1.88 10607 7907 2.12 2.54 12327 7873 2.47 3.36
85 9371 9371 1.87 2.01 10842 9355 2.17 2.64 12477 9282 2.50 3.44
76 7349 5589 1.47 1.28 8674 5569 1.74 1.74 9966 5505 1.99 2.26
78 7403 6048 1.48 1.30 8688 6012 1.74 1.75 10145 6019 2.03 2.33
FB 2 M 221
80 7449 6503 1.49 1.31 8707 6453 1.74 1.75 10111 6441 2.02 2.32
85 7709 7701 1.54 1.40 8877 7616 1.78 1.82 10358 7635 2.07 2.43
76 5604 4210 1.12 0.77 6649 4227 1.33 1.06 7647 4202 1.53 1.38
78 5797 4616 1.16 0.82 6695 4572 1.34 1.08 7733 4559 1.55 1.41
L 158
80 5814 4950 1.16 0.83 6697 4893 1.34 1.08 7811 4918 1.56 1.43
85 5919 5802 1.18 0.86 6925 5800 1.39 1.15 7884 5755 1.58 1.46
76 10055 7812 2.01 2.30 11948 7765 2.39 3.17 13872 7691 2.77 4.19
78 10227 8509 2.05 2.37 12099 8455 2.42 3.24 14018 8381 2.80 4.28
H 340
80 10269 9156 2.05 2.39 12194 9122 2.44 3.29 14139 9057 2.83 4.35
85 10713 10713 2.14 2.58 12502 10821 2.50 3.45 14479 10764 2.90 4.54
76 8816 6795 1.76 1.80 10365 6723 2.07 2.43 12086 6693 2.42 3.24
78 8959 7391 1.79 1.85 10450 7302 2.09 2.47 12207 7286 2.44 3.30
FB 3 M 283
80 9047 7970 1.81 1.88 10607 7907 2.12 2.54 12327 7873 2.47 3.36
85 9371 9371 1.87 2.01 10842 9355 2.17 2.64 12477 9282 2.50 3.44
76 7349 5589 1.47 1.28 8674 5569 1.74 1.74 9966 5505 1.99 2.26
78 7403 6048 1.48 1.30 8688 6012 1.74 1.75 10145 6019 2.03 2.33
L 221
80 7449 6503 1.49 1.31 8707 6453 1.74 1.75 10111 6441 2.02 2.32
85 7709 7701 1.54 1.40 8877 7616 1.78 1.82 10358 7635 2.07 2.43
76 11852 9212 2.37 3.12 14026 9131 2.81 4.28 16462 9096 3.29 5.78
78 12095 10059 2.42 3.24 14365 10013 2.87 4.48 16644 9913 3.33 5.90
H 422
80 12189 10841 2.44 3.29 14425 10779 2.89 4.51 16825 10729 3.37 6.02
85 12811 12811 2.56 3.61 14820 12800 2.96 4.75 17101 12700 3.42 6.21
76 10454 8130 2.09 2.47 12505 8110 2.50 3.45 14435 8003 2.89 4.52
78 10578 8831 2.12 2.52 12501 8765 2.50 3.45 14589 8717 2.92 4.61
FB 4 M 358
80 10749 9558 2.15 2.60 12758 9522 2.55 3.58 14786 9454 2.96 4.73
85 11234 11234 2.25 2.82 12993 11255 2.60 3.71 15029 11187 3.01 4.87
76 8708 6692 1.74 1.75 10262 6642 2.05 2.38 11896 6587 2.38 3.14
78 8796 7257 1.76 1.79 10370 7216 2.07 2.43 11986 7153 2.40 3.19
L 277
80 8882 7827 1.78 1.82 10365 7744 2.07 2.43 12102 7734 2.42 3.25
85 9196 9196 1.84 1.94 10641 9186 2.13 2.55 12241 9113 2.45 3.32
76 16882 12659 3.38 6.81 19879 12593 3.98 9.24 22999 12506 4.60 12.13
78 17017 13699 3.40 6.91 20050 13641 4.01 9.39 23170 13555 4.63 12.30
H 554
80 17140 14731 3.43 7.00 20215 14691 4.04 9.53 23422 14643 4.68 12.55
85 17649 17391 3.53 7.40 20611 17305 4.12 9.88 23846 17271 4.77 12.98
76 14750 11114 2.95 5.29 17425 11077 3.49 7.22 20241 11043 4.05 9.55
78 14968 12072 2.99 5.44 17567 11998 3.51 7.33 20414 11976 4.08 9.71
FB 5 M 470
80 15096 12994 3.02 5.53 17699 12918 3.54 7.43 20594 12916 4.12 9.87
85 15464 15295 3.09 5.78 18119 15253 3.62 7.77 20856 15179 4.17 10.10
76 12446 9346 2.49 3.86 14653 9315 2.93 5.23 17006 9291 3.40 6.90
78 12566 10113 2.51 3.93 14778 10085 2.96 5.31 17158 10076 3.43 7.02
L 377
80 12731 10908 2.55 4.02 14899 10858 2.98 5.39 17147 10789 3.43 7.01
85 12973 12803 2.60 4.17 15132 12753 3.03 5.55 17512 12743 3.50 7.29
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
10
RAC
PERFORMANCE DATA TABLES
FB (3-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 17834 13439 3.57 7.54 21057 13374 4.21 10.29 24448 13303 4.89 13.60
78 18146 14622 3.63 7.79 21286 14517 4.26 10.50 24706 14454 4.94 13.87
H 601
80 18290 15727 3.66 7.91 21469 15646 4.29 10.66 24880 15583 4.98 14.06
85 18708 18523 3.74 8.25 21936 18461 4.39 11.10 25379 18401 5.08 14.59
76 16309 12267 3.26 6.38 19238 12208 3.85 8.69 22318 12147 4.46 11.47
78 16421 13265 3.28 6.46 19476 13262 3.90 8.89 22546 13193 4.51 11.69
FB 6 M 533
80 16693 14335 3.34 6.67 19616 14271 3.92 9.01 22632 14184 4.53 11.77
85 17137 16890 3.43 7.00 20034 16824 4.01 9.37 23021 16726 4.60 12.15
76 14104 10604 2.82 4.87 16495 10502 3.30 6.52 19202 10484 3.84 8.66
78 14152 11446 2.83 4.90 16782 11448 3.36 6.73 19458 11417 3.89 8.87
L 441
80 14318 12329 2.86 5.01 16872 12303 3.37 6.80 19477 12244 3.90 8.89
85 14732 14551 2.95 5.28 17162 14471 3.43 7.02 19846 14449 3.97 9.21
76 21769 16086 4.35 12.00 25524 16004 5.11 16.14 29514 15930 5.90 21.16
78 22045 17422 4.41 12.29 25798 17338 5.16 16.46 29877 17299 5.98 21.65
H 693
80 22238 18732 4.45 12.49 26059 18673 5.21 16.77 30022 18590 6.00 21.84
85 22764 22004 4.55 13.04 26488 21913 5.30 17.29 30598 21887 6.12 22.63
76 19418 14380 3.88 9.70 22823 14334 4.57 13.10 26412 14291 5.28 17.20
78 19691 15587 3.94 9.96 23008 15509 4.60 13.30 26629 15477 5.33 17.46
FB 8 M 600
80 19780 16713 3.96 10.04 23178 16675 4.64 13.49 26801 16645 5.36 17.68
85 20202 19627 4.04 10.44 23560 19560 4.71 13.90 27205 19549 5.44 18.18
76 16959 12538 3.39 7.55 19784 12457 3.96 10.05 22940 12448 4.59 13.23
78 17131 13560 3.43 7.69 20060 13515 4.01 10.31 23041 13436 4.61 13.34
L 503
80 17277 14572 3.46 7.81 20137 14505 4.03 10.38 23193 14452 4.64 13.50
85 17468 17018 3.49 7.97 20470 17009 4.09 10.70 23537 16962 4.71 13.88
76 31972 23648 6.39 14.09 37668 23580 7.53 19.13 43565 23475 8.71 25.11
78 32411 25623 6.48 14.45 37933 25504 7.59 19.39 43952 25438 8.79 25.53
H 1036
80 32666 27546 6.53 14.67 38330 27466 7.67 19.77 44304 27381 8.86 25.91
85 33498 32389 6.70 15.37 39101 32291 7.82 20.52 45068 32220 9.01 26.76
76 28985 21371 5.80 11.74 33969 21266 6.79 15.78 39331 21203 7.87 20.74
78 29301 23123 5.86 11.98 34311 23029 6.86 16.07 39636 22950 7.93 21.04
FB 10 M 907
80 29607 24864 5.92 12.21 34622 24772 6.92 16.35 39892 24691 7.98 21.30
85 30285 29178 6.06 12.74 35246 29086 7.05 16.90 40577 29015 8.12 21.99
76 24467 18074 4.89 8.56 28715 18019 5.74 11.54 33103 17943 6.62 15.04
78 24744 19563 4.95 8.75 28944 19486 5.79 11.71 33358 19420 6.67 15.25
L 733
80 24934 21004 4.99 8.87 29194 20963 5.84 11.90 33599 20886 6.72 15.46
85 25405 24614 5.08 9.19 29576 24534 5.92 12.19 34030 24490 6.81 15.83
76 34977 25889 7.00 16.66 41125 25767 8.23 22.55 47739 25697 9.55 29.80
78 35280 27986 7.06 16.93 41554 27931 8.31 22.99 48100 27814 9.62 30.22
H 1165
80 35780 30197 7.16 17.38 41911 30053 8.38 23.36 48469 29968 9.69 30.66
85 36582 35459 7.32 18.12 42774 35347 8.56 24.26 49318 35270 9.86 31.67
76 31478 23230 6.30 13.69 36950 23129 7.39 18.46 42671 22997 8.53 24.16
78 31732 25095 6.35 13.90 37323 25036 7.47 18.81 43020 24918 8.60 24.53
FB 12 M 1009
80 32047 26998 6.41 14.15 37517 26893 7.50 18.99 43358 26822 8.67 24.89
85 32787 31701 6.56 14.77 38264 31593 7.65 19.70 44096 31533 8.82 25.69
76 28021 20665 5.60 11.02 32890 20596 6.58 14.86 37994 20516 7.60 19.44
78 28313 22366 5.66 11.24 33183 22286 6.64 15.10 38267 22186 7.65 19.71
L 869
80 28583 24044 5.72 11.44 33452 23974 6.69 15.33 38573 23885 7.72 20.00
85 29097 28157 5.82 11.82 34047 28123 6.81 15.85 39159 28050 7.83 20.57
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
11
RAC
PERFORMANCE DATA TABLES
FB (4-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 9517 7191 1.90 2.53 11271 7188 2.25 3.46 12958 7126 2.59 4.48
78 9640 7802 1.93 2.59 11405 7806 2.28 3.54 13131 7757 2.63 4.59
H 280
80 9740 8395 1.95 2.64 11382 8351 2.28 3.52 13167 8328 2.63 4.62
85 9803 9803 1.96 2.67 11507 9795 2.30 3.60 13258 9760 2.65 4.67
76 7830 5851 1.57 1.77 9217 5851 1.84 2.39 10602 5816 2.12 3.09
78 7956 6354 1.59 1.82 9327 6343 1.87 2.44 10699 6303 2.14 3.14
FB 2 M 218
80 7966 6801 1.59 1.82 9303 6776 1.86 2.43 10787 6790 2.16 3.19
85 8116 7981 1.62 1.89 9512 7981 1.90 2.53 10897 7950 2.18 3.25
76 6010 4420 1.20 1.09 6963 4389 1.39 1.42 8048 4397 1.61 1.86
78 6150 4809 1.23 1.13 7107 4780 1.42 1.48 8143 4769 1.63 1.90
L 156
80 6143 5134 1.23 1.13 7087 5102 1.42 1.47 8099 5077 1.62 1.88
85 6337 6042 1.27 1.20 7230 5983 1.45 1.53 8236 5955 1.65 1.94
76 10965 8333 2.19 3.29 12917 8288 2.58 4.45 14991 8251 3.00 5.87
78 11136 9054 2.23 3.38 13055 8997 2.61 4.54 15082 8937 3.02 5.94
H 336
80 11149 9709 2.23 3.39 13179 9700 2.64 4.62 15173 9631 3.04 6.00
85 11355 11355 2.27 3.51 13328 11384 2.67 4.72 15402 11354 3.08 6.17
76 9517 7191 1.90 2.53 11271 7188 2.25 3.46 12958 7126 2.59 4.48
78 9640 7802 1.93 2.59 11405 7806 2.28 3.54 13131 7757 2.63 4.59
FB 3 M 280
80 9740 8395 1.95 2.64 11382 8351 2.28 3.52 13167 8328 2.63 4.62
85 9803 9803 1.96 2.67 11507 9795 2.30 3.60 13258 9760 2.65 4.67
76 7830 5851 1.57 1.77 9217 5851 1.84 2.39 10602 5816 2.12 3.09
78 7956 6354 1.59 1.82 9327 6343 1.87 2.44 10699 6303 2.14 3.14
L 218
80 7966 6801 1.59 1.82 9303 6776 1.86 2.43 10787 6790 2.16 3.19
85 8116 7981 1.62 1.89 9512 7981 1.90 2.53 10897 7950 2.18 3.25
76 12908 9850 2.58 4.45 15235 9796 3.05 6.05 17766 9762 3.55 8.05
78 13054 10694 2.61 4.54 15416 10646 3.08 6.18 17950 10617 3.59 8.20
H 416
80 13174 11521 2.64 4.62 15472 11447 3.09 6.22 18112 11463 3.62 8.34
85 13388 13388 2.68 4.76 15737 13492 3.15 6.42 18218 13444 3.64 8.43
76 11469 8709 2.29 3.57 13507 8659 2.70 4.84 15625 8603 3.13 6.34
78 11546 9418 2.31 3.62 13658 9406 2.73 4.94 15775 9343 3.16 6.45
FB 4 M 354
80 11572 10110 2.31 3.63 13675 10087 2.74 4.95 15877 10069 3.18 6.53
85 11900 11900 2.38 3.83 13773 11829 2.76 5.02 16014 11823 3.20 6.63
76 9343 7058 1.87 2.45 11064 7059 2.21 3.34 12721 6997 2.54 4.33
78 9540 7685 1.91 2.54 11193 7659 2.24 3.42 12888 7615 2.58 4.44
L 274
80 9560 8244 1.91 2.55 11171 8200 2.23 3.40 12922 8175 2.58 4.46
85 9734 9677 1.95 2.64 11292 9610 2.26 3.47 13010 9575 2.60 4.51
76 18022 13429 3.60 9.37 21132 13356 4.23 12.58 24515 13333 4.90 16.55
78 18182 14512 3.64 9.53 21358 14470 4.27 12.83 24582 14383 4.92 16.64
H 548
80 18313 15595 3.66 9.66 21409 15518 4.28 12.88 24774 15496 4.96 16.88
85 18492 18230 3.70 9.83 21699 18208 4.34 13.21 25025 18164 5.01 17.20
76 15872 11788 3.17 7.42 18603 11740 3.72 9.94 21433 11680 4.29 12.91
78 15951 12712 3.19 7.48 18610 12645 3.72 9.95 21605 12642 4.32 13.10
FB 5 M 464
80 16031 13643 3.21 7.55 18774 13603 3.76 10.11 21709 13580 4.34 13.22
85 16243 15962 3.25 7.74 18925 15906 3.79 10.26 21842 15871 4.37 13.37
76 13352 9869 2.67 5.39 15533 9805 3.11 7.13 17957 9792 3.59 9.31
78 13439 10649 2.69 5.46 15639 10588 3.13 7.22 18015 10554 3.60 9.37
L 373
80 13466 11399 2.69 5.48 15724 11367 3.15 7.29 18185 11373 3.64 9.53
85 13687 13348 2.74 5.65 15911 13296 3.18 7.45 18375 13309 3.68 9.72
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
12
RAC
PERFORMANCE DATA TABLES
FB (4-Rows cooling)
Entering Wet Bulb Temperature
Model Fan AFR DBT 63 65 67
speed
T.cap S.cap GPM WPD T.cap S.cap GPM WPD T.cap S.cap GPM WPD
76 19087 14269 3.82 10.42 22488 14225 4.50 14.11 26148 14214 5.23 18.65
78 19289 15451 3.86 10.63 22650 15394 4.53 14.30 26195 15325 5.24 18.72
H 594
80 19465 16620 3.89 10.81 22744 16527 4.55 14.41 26297 16465 5.26 18.85
85 19687 19445 3.94 11.03 23101 19416 4.62 14.83 26636 19360 5.33 19.30
76 17413 12991 3.48 8.80 20529 12971 4.11 11.92 23701 12898 4.74 15.55
78 17561 14042 3.51 8.94 20635 14006 4.13 12.04 23870 13967 4.77 15.76
FB 6 M 527
80 17682 15091 3.54 9.05 20679 15021 4.14 12.08 23935 14989 4.79 15.84
85 17901 17429 3.58 9.26 20946 17611 4.19 12.37 24243 17633 4.85 16.22
76 15028 11172 3.01 6.71 17618 11135 3.52 8.99 20362 11097 4.07 11.74
78 15106 12058 3.02 6.77 17773 12043 3.56 9.14 20465 11994 4.09 11.85
L 436
80 15178 12934 3.04 6.83 17776 12894 3.56 9.14 20556 12885 4.11 11.95
85 15369 15131 3.07 6.99 18006 15113 3.60 9.36 20796 15106 4.16 12.21
76 22971 16929 4.59 16.22 27041 16927 5.41 21.91 31117 16832 6.22 28.38
78 23218 18320 4.64 16.54 27129 18248 5.43 22.04 31360 18219 6.27 28.79
H 684
80 23293 19634 4.66 16.64 27304 19590 5.46 22.30 31453 19535 6.29 28.95
85 23601 22936 4.72 17.05 27607 22908 5.52 22.76 31713 22836 6.34 29.39
76 20491 15108 4.10 13.15 24093 15105 4.82 17.71 27753 15039 5.55 22.98
78 20688 16357 4.14 13.38 24161 16269 4.83 17.80 27914 16249 5.58 23.23
FB 8 M 593
80 20728 17482 4.15 13.43 24367 17484 4.87 18.08 28054 17446 5.61 23.44
85 21033 20449 4.21 13.79 24564 20413 4.91 18.35 28294 20387 5.66 23.81
76 17846 13111 3.57 10.20 20870 13079 4.17 13.60 23873 12975 4.78 17.41
78 18037 14167 3.61 10.40 21012 14123 4.20 13.77 24155 14076 4.83 17.79
L 497
80 18089 15168 3.62 10.46 21136 15151 4.23 13.92 24220 15080 4.84 17.88
85 18247 17675 3.65 10.62 21321 17668 4.26 14.14 24443 17623 4.89 18.19
76 33847 24945 6.77 19.01 39827 24927 7.97 25.67 45976 24833 9.20 33.48
78 34173 26976 6.84 19.35 39990 26869 8.00 25.87 46175 26799 9.24 33.75
H 1023
80 34329 28924 6.87 19.52 40142 28817 8.03 26.05 46382 28785 9.28 34.03
85 34735 33788 6.95 19.94 40612 33726 8.12 26.62 46835 33685 9.37 34.65
76 30510 22448 6.10 15.70 35748 22401 7.15 21.03 41341 22361 8.27 27.51
78 30745 24233 6.15 15.93 35999 24192 7.20 21.30 41617 24157 8.32 27.85
FB 10 M 896
80 30938 26014 6.19 16.11 36202 25961 7.24 21.53 41709 25903 8.34 27.96
85 31334 30396 6.27 16.49 36603 30356 7.32 21.97 42120 30300 8.42 28.47
76 25829 18955 5.17 11.56 30190 18905 6.04 15.40 34661 18810 6.93 19.87
78 25983 20428 5.20 11.68 30302 20361 6.06 15.51 34947 20343 6.99 20.17
L 724
80 26079 21888 5.22 11.76 30454 21841 6.09 15.65 35069 21805 7.01 20.30
85 26413 25561 5.28 12.04 30774 25505 6.16 15.95 35262 25426 7.05 20.51
76 37045 27334 7.41 22.46 43594 27292 8.72 30.34 50461 27211 10.09 39.78
78 37288 29530 7.46 22.73 43849 29462 8.77 30.67 50722 29401 10.14 40.16
H 1151
80 37529 31689 7.51 23.01 44032 31626 8.81 30.91 50930 31565 10.19 40.46
85 38111 37096 7.62 23.67 44535 37005 8.91 31.56 51353 36921 10.27 41.09
76 33279 24483 6.66 18.43 38974 24394 7.80 24.67 44993 24317 9.00 32.17
78 33438 26391 6.69 18.59 39129 26299 7.83 24.85 45233 26259 9.05 32.49
FB 12 M 997
80 33588 28298 6.72 18.75 39429 28272 7.89 25.20 45377 28167 9.08 32.68
85 34062 33100 6.81 19.24 39831 33050 7.97 25.68 45809 32962 9.16 33.26
76 29558 21719 5.91 14.81 34577 21650 6.92 19.78 39985 21629 8.00 25.86
78 29682 23406 5.94 14.93 34772 23372 6.95 19.98 40063 23290 8.01 25.96
L 858
80 29865 25109 5.97 15.10 34960 25073 6.99 20.18 40294 25024 8.06 26.23
85 30291 29366 6.06 15.49 35300 29297 7.06 20.55 40634 29245 8.13 26.64
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• 0.1 inch of water external static pressure DBT : Entering Dry Bulb Temperature (OF)
• (For lower water pressure drop, special coil T.cap. : Total Cooling Capacity in (Btu/hr)
circuiting please consult PETRA factory). S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
13
RAC
PERFORMANCE DATA TABLES (FB)
(3-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 283 16552 3.31 4.91 14812 1.48 1.09 13012 0.87 0.40 11048 0.55 0.18
FB 2 M 221 13001 2.60 3.12 12078 1.21 0.75 10672 0.71 0.28 9139 0.46 0.12
L 158 9552 1.91 1.75 9222 0.92 0.45 8133 0.54 0.17 7036 0.35 0.08
H 340 19008 3.80 6.37 17206 1.72 1.44 15043 1.00 0.53 12522 0.63 0.22
FB 3 M 283 16552 3.31 4.91 14812 1.48 1.09 13012 0.87 0.40 11048 0.55 0.18
L 221 13001 2.60 3.12 12078 1.21 0.75 10672 0.71 0.28 9139 0.46 0.12
H 422 22820 4.56 8.99 20440 2.04 1.99 17877 1.19 0.73 14787 0.74 0.30
FB 4 M 358 19928 3.99 6.96 17961 1.80 1.56 15787 1.05 0.58 13189 0.66 0.24
L 277 16280 3.26 4.76 14498 1.45 1.05 12736 0.85 0.39 10814 0.54 0.17
H 554 30839 6.17 17.67 27795 2.78 3.98 24751 1.65 1.51 21066 1.05 0.66
FB 5 M 470 26436 5.29 13.23 24260 2.43 3.09 21678 1.45 1.18 18688 0.93 0.53
L 377 21918 4.38 9.32 20223 2.02 2.21 18260 1.22 0.86 15862 0.79 0.39
H 601 32586 6.52 19.60 29631 2.96 4.49 26329 1.76 1.70 22154 1.11 0.72
FB 6 M 533 29670 5.93 16.43 26895 2.69 3.75 23967 1.60 1.43 20576 1.03 0.63
L 441 25217 5.04 12.11 23018 2.30 2.80 20659 1.38 1.08 17790 0.89 0.48
H 693 38526 7.71 29.26 35320 3.53 6.84 31712 2.11 2.65 27504 1.38 1.20
FB 8 M 600 33755 6.75 22.85 31317 3.13 5.47 28281 1.89 2.14 24724 1.24 0.99
L 503 29628 5.93 17.91 26981 2.70 4.15 24509 1.63 1.65 21600 1.08 0.77
H 1036 56396 11.28 34.23 51902 5.19 8.03 46660 3.11 3.11 40518 2.03 1.41
FB 10 M 907 50423 10.09 27.75 46620 4.66 6.58 41899 2.79 2.55 36653 1.83 1.17
L 733 42560 8.51 20.20 39054 3.91 4.74 35504 2.37 1.88 31158 1.56 0.87
H 1165 62239 12.45 41.18 57017 5.70 9.57 51122 3.41 3.68 44132 2.21 1.65
FB 12 M 1009 56093 11.22 33.88 50841 5.08 7.73 45735 3.05 2.99 39608 1.98 1.35
L 869 48687 9.74 25.99 45044 4.50 6.17 40646 2.71 2.41 35495 1.78 1.10
(4-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 280 16537 3.31 5.92 15627 1.56 1.48 14007 0.93 0.57 12388 0.62 0.27
FB 2 M 218 13255 2.65 3.93 12684 1.27 1.01 11410 0.76 0.39 10023 0.50 0.18
L 156 9807 1.96 2.25 9261 0.93 0.57 8751 0.58 0.24 7669 0.38 0.11
H 336 19487 3.90 8.03 17975 1.80 1.91 16226 1.08 0.75 14088 0.70 0.34
FB 3 M 280 16537 3.31 5.92 15627 1.56 1.48 14007 0.93 0.57 12388 0.62 0.27
L 218 13255 2.65 3.93 12684 1.27 1.01 11410 0.76 0.39 10023 0.50 0.18
H 416 23381 4.68 11.27 21533 2.15 2.67 19187 1.28 1.02 16661 0.83 0.47
FB 4 M 354 20755 4.15 9.03 18887 1.89 2.10 16942 1.13 0.81 14690 0.73 0.37
L 274 16273 3.26 5.74 15292 1.53 1.42 13866 0.92 0.56 12123 0.61 0.26
H 548 31324 6.27 21.92 29078 2.91 5.30 26384 1.76 2.11 23215 1.16 0.99
FB 5 M 464 26997 5.40 16.63 25292 2.53 4.10 23145 1.54 1.66 20462 1.02 0.78
L 373 22229 4.45 11.61 20914 2.09 2.89 19253 1.28 1.18 17204 0.86 0.57
H 594 33405 6.68 24.70 31004 3.10 5.97 28084 1.87 2.36 24649 1.23 1.10
FB 6 M 527 30424 6.09 20.76 28116 2.81 4.98 25526 1.70 1.98 22478 1.12 0.93
L 436 25632 5.13 15.11 24270 2.43 3.80 22001 1.47 1.51 19479 0.97 0.72
H 684 39240 7.85 36.62 36493 3.65 8.93 33526 2.24 3.64 29768 1.49 1.73
FB 8 M 593 34564 6.91 28.96 33009 3.30 7.43 29923 2.00 2.96 26665 1.33 1.42
L 497 29525 5.91 21.65 27809 2.78 5.42 25797 1.72 2.25 23210 1.16 1.10
H 1023 57815 11.56 43.02 53913 5.39 10.51 49402 3.29 4.25 43855 2.19 2.02
FB 10 M 896 52085 10.42 35.45 48257 4.83 8.57 44370 2.96 3.49 39577 1.98 1.68
L 724 42770 8.55 24.62 40354 4.04 6.17 37214 2.48 2.53 33445 1.67 1.23
H 1151 63987 12.80 51.93 59411 5.94 12.56 54252 3.62 5.05 47845 2.39 2.37
FB 12 M 997 56454 11.29 41.16 52831 5.28 10.12 48363 3.22 4.09 43029 2.15 1.95
L 858 50407 10.08 33.36 46582 4.66 8.03 42861 2.86 3.28 38271 1.91 1.58
(1-Row heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 295 8519 1.704 0.781 6427 0.643 0.116 4401 0.293 0.025 2638 0.132 0.005
FB 2 M 230 7229 1.446 0.566 5391 0.539 0.083 3839 0.256 0.020 2381 0.119 0.005
L 165 5708 1.142 0.357 4461 0.446 0.057 3189 0.213 0.014 2049 0.102 0.003
H 354 9655 1.931 0.999 7161 0.716 0.144 4861 0.324 0.031 2825 0.141 0.006
FB 3 M 295 8519 1.704 0.781 6427 0.643 0.116 4401 0.293 0.025 2638 0.132 0.005
L 230 7229 1.446 0.566 5391 0.539 0.083 3839 0.256 0.020 2381 0.119 0.005
H 439 11054 2.211 1.303 8047 0.805 0.180 5455 0.364 0.039 3078 0.154 0.007
FB 4 M 373 9998 2.000 1.070 7345 0.735 0.151 5028 0.335 0.033 2956 0.148 0.007
L 289 8413 1.683 0.762 6240 0.624 0.110 4378 0.292 0.025 2632 0.132 0.005
H 577 15394 3.079 2.678 11942 1.194 0.423 8746 0.583 0.106 5675 0.284 0.027
FB 5 M 488 13835 2.767 2.173 10830 1.083 0.350 7951 0.530 0.088 5310 0.266 0.023
L 392 11941 2.388 1.630 9348 0.935 0.263 6986 0.466 0.069 4734 0.237 0.019
H 625 16230 3.246 2.969 12462 1.246 0.460 9141 0.609 0.115 5940 0.297 0.029
FB 6 M 555 15061 3.012 2.566 11618 1.162 0.401 8558 0.571 0.102 5629 0.281 0.026
L 459 13223 2.645 1.989 10380 1.038 0.323 7672 0.511 0.082 5103 0.255 0.022
H 721 19696 3.939 4.585 15761 1.576 0.775 12020 0.801 0.211 8485 0.424 0.063
FB 8 M 624 17883 3.577 3.799 14475 1.447 0.658 11042 0.736 0.179 7774 0.389 0.053
L 524 15978 3.196 3.051 12901 1.290 0.527 9925 0.662 0.146 7107 0.355 0.045
H 1079 28666 5.733 5.468 22964 2.296 0.926 17598 1.173 0.254 12360 0.618 0.075
FB 10 M 945 26306 5.261 4.625 21175 2.117 0.792 16283 1.086 0.219 11528 0.576 0.065
L 763 22789 4.558 3.498 18471 1.847 0.608 14341 0.956 0.172 10277 0.514 0.052
H 1212 30966 6.193 6.356 24730 2.473 1.069 18808 1.254 0.289 13098 0.655 0.083
FB 12 M 1050 28236 5.647 5.309 22644 2.264 0.901 17322 1.155 0.247 12187 0.609 0.073
L 904 25570 5.114 4.376 20603 2.060 0.751 15860 1.057 0.208 11246 0.562 0.062
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
15
RAC
PERFORMANCE DATA TABLES
GCC (3-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
16
RAC
PERFORMANCE DATA TABLES
GCC (4-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
17
RAC
PERFORMANCE DATA TABLES
GCC (4-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
18
RAC
PERFORMANCE DATA TABLES (GCC)
(3-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 305 17526 3.51 5.47 15787 1.58 1.23 13847 0.92 0.45 11730 0.59 0.20
GCC 2 M 237 13882 2.78 3.53 12747 1.28 0.82 11308 0.75 0.31 9663 0.48 0.14
L 169 10254 2.05 2.00 9724 0.97 0.50 8699 0.58 0.19 7526 0.38 0.09
H 367 20429 4.09 7.30 18307 1.83 1.62 16078 1.07 0.60 13352 0.67 0.25
GCC 3 M 305 17526 3.51 5.47 15787 1.58 1.23 13847 0.92 0.45 11730 0.59 0.20
L 237 13882 2.78 3.53 12747 1.28 0.82 11308 0.75 0.31 9663 0.48 0.14
H 454 24222 4.84 10.06 21727 2.17 2.23 18839 1.26 0.80 15591 0.78 0.33
GCC 4 M 386 21487 4.30 8.02 19031 1.90 1.74 16687 1.11 0.64 13893 0.70 0.27
L 299 17263 3.45 5.31 15477 1.55 1.18 13747 0.92 0.45 11499 0.58 0.19
H 597 33232 6.65 20.77 29952 3.00 4.68 26672 1.78 1.78 22874 1.14 0.79
GCC 5 M 507 28558 5.71 15.63 26170 2.62 3.64 23384 1.56 1.40 20305 1.02 0.63
L 406 23537 4.71 10.88 21778 2.18 2.59 19665 1.31 1.01 17082 0.85 0.46
H 647 35080 7.02 22.99 31899 3.19 5.27 28532 1.90 2.02 23852 1.19 0.85
GCC 6 M 575 32008 6.40 19.36 29015 2.90 4.42 26022 1.74 1.70 22364 1.12 0.76
L 474 27038 5.41 14.11 24741 2.47 3.28 22273 1.49 1.28 19258 0.96 0.57
H 745 40663 8.13 32.35 37324 3.73 7.57 33500 2.23 2.93 29029 1.45 1.32
GCC 8 M 646 35960 7.19 25.71 33158 3.32 6.08 29795 1.99 2.36 26059 1.30 1.08
L 540 31203 6.24 19.72 28810 2.88 4.69 25999 1.73 1.83 22720 1.14 0.84
H 1113 60185 12.04 38.99 55277 5.53 9.11 49645 3.31 3.52 43047 2.15 1.59
GCC 10 M 978 54370 10.87 32.22 49845 4.98 7.52 44896 2.99 2.92 39098 1.96 1.33
L 788 45171 9.03 22.78 41643 4.16 5.38 37883 2.53 2.14 33211 1.66 0.99
H 1255 66503 13.30 47.02 60878 6.09 10.90 54527 3.64 4.19 46382 2.32 1.82
GCC 12 M 1085 58985 11.80 37.54 54200 5.42 8.78 48710 3.25 3.40 42199 2.11 1.53
L 937 52091 10.42 29.74 48026 4.80 7.02 43285 2.89 2.73 37866 1.89 1.26
(4-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 301 17688 3.54 6.71 16799 1.68 1.69 14884 0.99 0.64 12969 0.65 0.29
GCC 2 M 234 14106 2.82 4.41 13341 1.33 1.11 12112 0.81 0.44 10624 0.53 0.21
L 167 10406 2.08 2.51 9881 0.99 0.64 9272 0.62 0.27 8113 0.41 0.13
H 363 21158 4.23 9.36 19262 1.93 2.18 17267 1.15 0.84 15063 0.75 0.39
GCC 3 M 301 17688 3.54 6.71 16799 1.68 1.69 14884 0.99 0.64 12969 0.65 0.29
L 234 14106 2.82 4.41 13341 1.33 1.11 12112 0.81 0.44 10624 0.53 0.21
H 448 24938 4.99 12.71 22865 2.29 2.99 20469 1.37 1.15 17554 0.88 0.51
GCC 4 M 382 21993 4.40 10.06 20049 2.01 2.34 18061 1.20 0.92 15631 0.78 0.41
L 295 17425 3.49 6.52 16464 1.65 1.63 14587 0.97 0.62 12881 0.64 0.29
H 590 33604 6.72 25.56 31136 3.11 6.17 28407 1.89 2.48 25165 1.26 1.17
GCC 5 M 501 29750 5.95 20.39 27309 2.73 4.85 24991 1.67 1.96 22093 1.11 0.93
L 402 24018 4.80 13.72 22494 2.25 3.39 20808 1.39 1.40 18541 0.93 0.67
H 640 35848 7.17 28.82 33405 3.34 7.02 30259 2.02 2.78 26557 1.33 1.29
GCC 6 M 568 32668 6.53 24.25 30304 3.03 5.87 27512 1.83 2.34 24391 1.22 1.11
L 469 27433 5.49 17.55 26107 2.61 4.46 23666 1.58 1.77 20953 1.05 0.84
H 737 41596 8.32 40.77 38841 3.88 10.01 35537 2.37 4.04 31488 1.57 1.92
GCC 8 M 638 37232 7.45 33.21 34407 3.44 8.01 31640 2.11 3.27 28135 1.41 1.56
L 534 31496 6.30 24.38 29725 2.97 6.12 27409 1.83 2.52 24475 1.22 1.21
H 1100 61629 12.33 48.87 57494 5.75 11.94 52564 3.50 4.81 46679 2.33 2.29
GCC 10 M 967 55363 11.07 40.06 51661 5.17 9.81 47467 3.16 3.99 42294 2.12 1.91
L 779 45714 9.14 28.11 43307 4.33 7.09 39815 2.65 2.89 35648 1.78 1.40
H 1240 68935 13.79 60.17 63377 6.34 14.29 57820 3.86 5.73 51186 2.56 2.71
GCC 12 M 1073 60346 12.07 47.00 56393 5.64 11.53 51584 3.44 4.65 45844 2.29 2.21
L 926 53608 10.72 37.74 49805 4.98 9.17 45856 3.06 3.75 40902 2.05 1.80
(1-Row heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 317 8967 1.793 0.864 6619 0.662 0.123 4579 0.305 0.027 2703 0.135 0.006
GCC 2 M 246 7555 1.511 0.617 5750 0.575 0.094 3993 0.266 0.021 2442 0.122 0.005
L 176 6030 1.206 0.397 4630 0.463 0.062 3258 0.217 0.014 2115 0.106 0.004
H 381 10118 2.024 1.095 7398 0.740 0.153 5083 0.339 0.034 2955 0.148 0.007
GCC 3 M 317 8967 1.793 0.864 6619 0.662 0.123 4579 0.305 0.027 2703 0.135 0.006
L 246 7555 1.511 0.617 5750 0.575 0.094 3993 0.266 0.021 2442 0.122 0.005
H 471 11628 2.326 1.439 8427 0.843 0.197 5638 0.376 0.041 3237 0.162 0.008
GCC 4 M 400 10389 2.078 1.154 7626 0.763 0.162 5211 0.347 0.035 2945 0.147 0.007
L 310 8848 1.770 0.842 6561 0.656 0.121 4523 0.302 0.027 2649 0.132 0.006
H 619 16507 3.301 3.112 12894 1.289 0.499 9572 0.638 0.128 6340 0.317 0.034
GCC 5 M 525 14864 2.973 2.536 11768 1.177 0.418 8708 0.581 0.107 5918 0.296 0.029
L 421 12822 2.564 1.900 10101 1.010 0.311 7708 0.514 0.085 5257 0.263 0.024
H 671 17407 3.481 3.452 13647 1.365 0.557 10014 0.668 0.140 6691 0.335 0.037
GCC 6 M 596 16161 3.232 2.985 12627 1.263 0.480 9369 0.625 0.123 6282 0.314 0.033
L 492 14234 2.847 2.330 11205 1.120 0.381 8383 0.559 0.100 5681 0.284 0.027
H 774 20598 4.120 5.002 16450 1.645 0.842 12512 0.834 0.228 8668 0.433 0.065
GCC 8 M 670 18814 3.763 4.192 15087 1.509 0.712 11500 0.767 0.194 8100 0.405 0.057
L 561 16619 3.324 3.293 13442 1.344 0.570 10295 0.686 0.157 7349 0.367 0.048
H 1157 30470 6.094 6.191 24286 2.429 1.038 18606 1.240 0.285 13117 0.656 0.084
GCC 10 M 1015 27822 5.564 5.186 22410 2.241 0.889 17241 1.149 0.246 12238 0.612 0.074
L 818 24179 4.836 3.946 19534 1.953 0.682 15075 1.005 0.190 10874 0.544 0.059
H 1301 32718 6.544 7.113 26147 2.615 1.198 19874 1.325 0.323 13909 0.695 0.094
GCC 12 M 1126 29830 5.966 5.940 23876 2.388 1.005 18317 1.221 0.276 12932 0.647 0.082
L 973 27015 5.403 4.897 21826 2.183 0.845 16816 1.121 0.235 11945 0.597 0.070
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
20
RAC
PERFORMANCE DATA TABLES
GFC (3-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
21
RAC
PERFORMANCE DATA TABLES
GFC (4-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
22
RAC
PERFORMANCE DATA TABLES
GFC (4-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
23
RAC
PERFORMANCE DATA TABLES (GFC)
(3-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 283 25087 5.02 10.07 24938 2.49 2.71 22698 1.51 1.06 21154 1.06 0.55
GFC 2 M 221 20042 4.01 6.60 19417 1.94 1.69 18327 1.22 0.71 17323 0.87 0.38
L 158 14825 2.97 3.74 14185 1.42 0.94 13648 0.91 0.41 12995 0.65 0.22
H 340 29545 5.91 13.72 28196 2.82 3.41 26497 1.77 1.42 24643 1.23 0.73
GFC 3 M 283 25087 5.02 10.07 24938 2.49 2.71 22698 1.51 1.06 21154 1.06 0.55
L 221 20042 4.01 6.60 19417 1.94 1.69 18327 1.22 0.71 17323 0.87 0.38
H 422 35763 7.15 19.71 33846 3.39 4.80 31545 2.10 1.97 29244 1.46 1.00
GFC 4 M 358 30889 6.18 14.93 29364 2.94 3.67 27574 1.84 1.53 25703 1.29 0.79
L 277 24548 4.91 9.67 23562 2.36 2.43 22216 1.48 1.02 20832 1.04 0.53
H 554 49070 9.81 39.72 45188 4.52 9.25 42733 2.85 3.91 40090 2.01 2.03
GFC 5 M 470 40989 8.20 28.29 39351 3.94 7.14 37215 2.48 3.02 34973 1.75 1.58
L 377 33672 6.73 19.54 32392 3.24 4.96 30922 2.06 2.14 29209 1.46 1.13
H 601 50865 10.17 42.51 48407 4.84 10.52 45676 3.05 4.42 42740 2.14 2.29
GFC 6 M 533 45897 9.18 35.01 43657 4.37 8.67 41416 2.76 3.69 38692 1.94 1.90
L 441 38903 7.78 25.64 37123 3.71 6.40 35320 2.36 2.74 33316 1.67 1.44
H 693 61509 12.30 65.99 56841 5.68 15.54 54164 3.61 6.68 50936 2.55 3.50
GFC 8 M 600 52309 10.46 48.67 50235 5.02 12.34 48054 3.20 5.35 45327 2.27 2.82
L 503 44777 8.96 36.35 43160 4.32 9.30 41314 2.75 4.04 39142 1.96 2.15
H 1036 87857 17.57 73.85 83973 8.40 18.47 79854 5.32 7.89 75264 3.76 4.15
GFC 10 M 907 78635 15.73 59.93 75063 7.51 14.97 71560 4.77 6.44 67541 3.38 3.39
L 733 64854 12.97 41.71 64518 6.45 11.29 59705 3.98 4.60 56707 2.84 2.45
H 1165 97474 19.50 89.83 93238 9.32 22.46 87945 5.86 9.45 82651 4.13 4.93
GFC 12 M 1009 88171 17.63 74.35 82129 8.21 17.72 78117 5.21 7.58 73303 3.67 3.95
L 869 75457 15.09 55.45 72757 7.28 14.13 69006 4.60 6.02 65254 3.26 3.18
(4-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 280 25341 5.07 12.28 24744 2.47 3.24 23475 1.57 1.39 22457 1.12 0.76
GFC 2 M 218 20463 4.09 8.24 19422 1.94 2.07 18888 1.26 0.93 18128 0.91 0.51
L 156 14738 2.95 4.48 14583 1.46 1.22 13800 0.92 0.52 13476 0.67 0.30
H 336 29997 6.00 16.82 28943 2.89 4.33 27559 1.84 1.87 26032 1.30 0.99
GFC 3 M 280 25341 5.07 12.28 24744 2.47 3.24 23475 1.57 1.39 22457 1.12 0.76
L 218 20463 4.09 8.24 19422 1.94 2.07 18888 1.26 0.93 18128 0.91 0.51
H 416 36375 7.28 24.13 34877 3.49 6.12 32987 2.20 2.61 31096 1.56 1.37
GFC 4 M 354 31415 6.28 18.34 31408 3.14 5.04 28875 1.93 2.04 27266 1.36 1.08
L 274 24843 4.97 11.83 24178 2.42 3.10 23096 1.54 1.35 21976 1.10 0.73
H 548 48035 9.61 45.51 46379 4.64 11.77 44325 2.96 5.12 42146 2.11 2.75
GFC 5 M 464 41463 8.29 34.60 40161 4.02 9.02 38532 2.57 3.96 36740 1.84 2.14
L 373 34001 6.80 23.92 33093 3.31 6.31 33040 2.20 2.98 30424 1.52 1.51
H 594 51699 10.34 52.20 49733 4.97 13.39 47573 3.17 5.83 45009 2.25 3.10
GFC 6 M 527 46760 9.35 43.29 46140 4.61 11.66 42926 2.86 4.83 40770 2.04 2.59
L 436 39181 7.84 31.14 37940 3.79 8.12 36554 2.44 3.59 34969 1.75 1.95
H 684 60102 12.02 75.70 59775 5.98 20.76 55869 3.73 8.69 53227 2.66 4.69
GFC 8 M 593 52862 10.57 59.64 51245 5.13 15.63 49649 3.31 7.00 47493 2.38 3.81
L 497 44886 8.98 44.04 43874 4.39 11.74 43667 2.91 5.53 40595 2.03 2.86
H 1023 89119 17.82 90.16 85941 8.59 23.28 82571 5.51 10.23 78620 3.93 5.51
GFC 10 M 896 79218 15.84 72.41 79140 7.91 19.99 73745 4.92 8.31 70386 3.52 4.50
L 724 65468 13.09 50.80 63451 6.35 13.30 61275 4.09 5.92 58807 2.94 3.24
H 1151 102131 20.43 116.25 95256 9.53 28.16 91072 6.07 12.26 86626 4.33 6.59
GFC 12 M 997 87174 17.44 86.53 84097 8.41 22.36 80699 5.38 9.81 76961 3.85 5.30
L 858 76329 15.27 67.57 73806 7.38 17.57 71056 4.74 7.76 67937 3.40 4.22
(1-Row heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 295 8519 1.704 0.781 6427 0.643 0.116 4401 0.293 0.025 2638 0.132 0.005
GFC 2 M 230 7229 1.446 0.566 5391 0.539 0.083 3839 0.256 0.020 2381 0.119 0.005
L 165 5708 1.142 0.357 4461 0.446 0.057 3189 0.213 0.014 2049 0.102 0.003
H 354 9655 1.931 0.999 7161 0.716 0.144 4861 0.324 0.031 2825 0.141 0.006
GFC 3 M 295 8519 1.704 0.781 6427 0.643 0.116 4401 0.293 0.025 2638 0.132 0.005
L 230 7229 1.446 0.566 5391 0.539 0.083 3839 0.256 0.020 2381 0.119 0.005
H 439 11054 2.211 1.303 8047 0.805 0.180 5455 0.364 0.039 3078 0.154 0.007
GFC 4 M 373 9998 2.000 1.070 7345 0.735 0.151 5028 0.335 0.033 2956 0.148 0.007
L 289 8413 1.683 0.762 6240 0.624 0.110 4378 0.292 0.025 2632 0.132 0.005
H 577 15394 3.079 2.678 11942 1.194 0.423 8746 0.583 0.106 5675 0.284 0.027
GFC 5 M 488 13835 2.767 2.173 10830 1.083 0.350 7951 0.530 0.088 5310 0.266 0.023
L 392 11941 2.388 1.630 9348 0.935 0.263 6986 0.466 0.069 4734 0.237 0.019
H 625 16230 3.246 2.969 12462 1.246 0.460 9141 0.609 0.115 5940 0.297 0.029
GFC 6 M 555 15061 3.012 2.566 11618 1.162 0.401 8558 0.571 0.102 5629 0.281 0.026
L 459 13223 2.645 1.989 10380 1.038 0.323 7672 0.511 0.082 5103 0.255 0.022
H 721 19696 3.939 4.585 15761 1.576 0.775 12020 0.801 0.211 8485 0.424 0.063
GFC 8 M 624 17883 3.577 3.799 14475 1.447 0.658 11042 0.736 0.179 7774 0.389 0.053
L 524 15978 3.196 3.051 12901 1.290 0.527 9925 0.662 0.146 7107 0.355 0.045
H 1079 28666 5.733 5.468 22964 2.296 0.926 17598 1.173 0.254 12360 0.618 0.075
GFC 10 M 945 26306 5.261 4.625 21175 2.117 0.792 16283 1.086 0.219 11528 0.576 0.065
L 763 22789 4.558 3.498 18471 1.847 0.608 14341 0.956 0.172 10277 0.514 0.052
H 1212 30966 6.193 6.356 24730 2.473 1.069 18808 1.254 0.289 13098 0.655 0.083
GFC 12 M 1050 28236 5.647 5.309 22644 2.264 0.901 17322 1.155 0.247 12187 0.609 0.073
L 904 25570 5.114 4.376 20603 2.060 0.751 15860 1.057 0.208 11246 0.562 0.062
24
32
RAC
PERFORMANCE DATA TABLES
PCC/PFC (3-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
25
RAC
PERFORMANCE DATA TABLES
PCC/PFC (3-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
26
RAC
PERFORMANCE DATA TABLES
PCC/PFC (4-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
27
RAC
PERFORMANCE DATA TABLES
PCC/PFC (4-Rows cooling)
All data are based on. AFR : Air Flow Rate (CFM)
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High)
• (For lower water pressure drop, special coil DBT : Entering Dry Bulb Temperature (OF)
circuiting please consult PETRA factory). T.cap. : Total Cooling Capacity in (Btu/hr)
S.cap : Sensible Cooling Capacity in (Btu/hr)
GPM : Water Flow Rate in Gallon Per Minute
WPD : Water Pressure Drop in (ft of water)
28
RAC
PERFORMANCE DATA TABLES (PFC)
(3-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 305 16493 3.30 4.51 14729 1.47 0.99 12612 0.84 0.35 10142 0.51 0.14
PCC 2 M 237 13486 2.70 3.09 11993 1.20 0.67 10349 0.69 0.24 8553 0.43 0.10
L 169 10000 2.00 1.76 9090 0.91 0.40 7917 0.53 0.15 6549 0.33 0.06
H 367 19262 3.85 6.05 16927 1.69 1.29 14380 0.96 0.44 11578 0.58 0.17
PCC 3 M 305 16493 3.30 4.51 14729 1.47 0.99 12612 0.84 0.35 10142 0.51 0.14
L 237 13486 2.70 3.09 11993 1.20 0.67 10349 0.69 0.24 8553 0.43 0.10
H 454 24090 4.82 9.81 21465 2.15 2.15 18511 1.23 0.76 15269 0.76 0.31
PCC 4 M 386 21040 4.21 7.60 18808 1.88 1.68 16352 1.09 0.61 13532 0.68 0.25
L 299 17044 3.41 5.11 15304 1.53 1.14 13402 0.89 0.42 10992 0.55 0.17
H 597 30125 6.03 14.98 26499 2.65 3.18 22701 1.51 1.12 18365 0.92 0.44
PCC 5 M 507 26316 5.26 11.60 23384 2.34 2.52 20159 1.34 0.89 16400 0.82 0.36
L 406 21896 4.38 8.19 19665 1.97 1.82 16965 1.13 0.65 14026 0.70 0.27
H 647 34799 6.96 22.38 31712 3.17 5.14 28157 1.88 1.94 23866 1.19 0.84
PCC 6 M 575 32008 6.40 19.12 28848 2.89 4.31 25689 1.71 1.64 21865 1.09 0.72
L 474 26793 5.36 13.70 24603 2.46 3.21 21862 1.46 1.22 18984 0.95 0.55
H 745 40016 8.00 30.47 36570 3.66 7.05 32692 2.18 2.70 27523 1.38 1.16
PCC 8 M 646 35960 7.19 24.94 32597 3.26 5.70 29235 1.95 2.20 25312 1.27 0.99
L 540 30557 6.11 18.38 28185 2.82 4.35 25375 1.69 1.69 22095 1.11 0.77
H 1113 58978 11.80 36.00 53829 5.38 8.28 48036 3.20 3.15 41125 2.06 1.39
PCC 10 M 978 53027 10.61 29.47 48572 4.86 6.84 43482 2.90 2.62 37401 1.87 1.17
L 788 44149 8.83 20.90 40731 4.07 4.93 36402 2.43 1.89 31958 1.60 0.87
H 1255 65142 13.03 43.41 59245 5.92 9.91 52531 3.50 3.72 44923 2.25 1.64
PCC 12 M 1085 57808 11.56 34.67 52631 5.26 7.94 47141 3.14 3.05 40067 2.00 1.32
L 937 52091 10.42 28.51 46942 4.69 6.42 42065 2.80 2.47 36308 1.82 1.10
(4-Rows heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 301 17167 3.43 5.82 15580 1.56 1.34 13839 0.92 0.51 11750 0.59 0.22
PCC 2 M 234 13753 2.75 3.85 12586 1.26 0.90 11300 0.75 0.35 9676 0.48 0.16
L 167 10106 2.02 2.17 9592 0.96 0.55 8596 0.57 0.21 7437 0.37 0.10
H 363 20206 4.04 7.90 18107 1.81 1.77 16008 1.07 0.67 13338 0.67 0.28
PCC 3 M 301 17167 3.43 5.82 15580 1.56 1.34 13839 0.92 0.51 11750 0.59 0.22
L 234 13753 2.75 3.85 12586 1.26 0.90 11300 0.75 0.35 9676 0.48 0.16
H 448 24938 4.99 12.51 22606 2.26 2.87 20145 1.34 1.10 17295 0.87 0.49
PCC 4 M 382 21671 4.33 9.63 19828 1.98 2.26 17619 1.18 0.86 15299 0.77 0.39
L 295 17328 3.47 6.35 15952 1.60 1.51 14417 0.96 0.59 12540 0.63 0.27
H 590 31136 6.23 18.95 28236 2.82 4.34 24824 1.66 1.62 21084 1.05 0.70
PCC 5 M 501 27164 5.43 14.68 24701 2.47 3.39 21948 1.46 1.29 18476 0.92 0.55
L 402 22614 4.52 10.43 20692 2.07 2.44 18541 1.24 0.94 15868 0.79 0.42
H 640 35811 7.16 28.38 33220 3.32 6.85 30074 2.01 2.71 26372 1.32 1.26
PCC 6 M 568 32386 6.48 23.55 29975 3.00 5.67 27347 1.82 2.28 24062 1.20 1.06
L 469 27293 5.46 17.15 25565 2.56 4.23 23395 1.56 1.71 20818 1.04 0.82
H 737 41079 8.22 38.55 38201 3.82 9.37 34792 2.32 3.75 30636 1.53 1.76
PCC 8 M 638 36500 7.30 30.96 34038 3.40 7.58 30902 2.06 3.02 27581 1.38 1.45
L 534 31197 6.24 23.16 29725 2.97 5.91 26946 1.80 2.35 24012 1.20 1.13
H 1100 61152 12.23 46.00 56222 5.62 10.90 50814 3.39 4.29 45089 2.25 2.04
PCC 10 M 967 54302 10.86 36.89 50543 5.05 8.96 46208 3.08 3.61 40896 2.05 1.70
L 779 45889 9.18 26.99 42293 4.23 6.45 38802 2.59 2.62 34578 1.73 1.25
H 1240 66963 13.39 54.47 61943 6.19 13.04 56206 3.75 5.17 49303 2.47 2.40
M 1073 59651 11.93 43.92 55152 5.52 10.52 50188 3.35 4.20 44215 2.21 1.96
PCC 12
L 926 52281 10.46 34.38 48801 4.88 8.40 44651 2.98 3.39 39563 1.98 1.60
(1-Row heating)
Temperature Drop (F)
Model Fan Speed AFR 10 20 30 40
T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD T.CAP GPM WPD
H 317 7852 1.570 0.633 5455 0.545 0.079 3385 0.23 0.01 1649 0.082 0.002
PCC 2 M 246 6656 1.331 0.457 4653 0.465 0.058 3024 0.20 0.01 1555 0.078 0.002
L 176 5386 1.077 0.301 3793 0.379 0.039 2540 0.17 0.01 1349 0.067 0.001
H 381 8865 1.773 0.804 6071 0.607 0.098 3709 0.25 0.02 1769 0.088 0.002
PCC 3 M 317 7852 1.570 0.633 5455 0.545 0.079 3385 0.23 0.01 1649 0.082 0.002
L 246 6656 1.331 0.457 4653 0.465 0.058 3024 0.20 0.01 1555 0.078 0.002
H 471 11383 2.277 1.368 8137 0.814 0.182 5346 0.36 0.04 2998 0.150 0.007
PCC 4 M 400 10236 2.047 1.110 7348 0.735 0.149 4938 0.33 0.03 2758 0.138 0.006
L 310 8713 1.743 0.809 6352 0.635 0.112 4305 0.29 0.02 2530 0.127 0.005
H 619 13479 2.696 1.908 9526 0.953 0.248 6182 0.41 0.05 3389 0.169 0.009
PCC 5 M 525 12149 2.430 1.555 8671 0.867 0.206 5635 0.38 0.04 3143 0.157 0.008
L 421 10513 2.103 1.170 7696 0.770 0.163 5058 0.34 0.03 2912 0.146 0.007
H 671 17209 3.442 3.350 13291 1.329 0.525 9723 0.65 0.13 6387 0.319 0.034
PCC 6 M 596 15885 3.177 2.864 12357 1.236 0.456 9107 0.61 0.12 5960 0.298 0.030
L 492 14073 2.815 2.260 11031 1.103 0.366 8160 0.54 0.09 5411 0.271 0.025
H 774 20029 4.006 4.644 15685 1.569 0.750 11746 0.78 0.20 7995 0.400 0.054
PCC 8 M 670 18108 3.622 3.815 14368 1.437 0.633 10822 0.72 0.17 7448 0.372 0.047
L 561 16166 3.233 3.057 12885 1.288 0.513 9753 0.65 0.14 6753 0.338 0.039
H 1157 28974 5.795 5.465 22834 2.283 0.893 17104 1.14 0.23 11701 0.585 0.065
PCC 10 M 1015 26621 5.324 4.632 21089 2.109 0.766 15898 1.06 0.20 10939 0.547 0.057
L 818 23109 4.622 3.515 18467 1.847 0.592 14028 0.94 0.16 9833 0.492 0.047
H 1301 31223 6.245 6.325 24548 2.455 1.027 18348 1.22 0.27 12434 0.622 0.073
PCC 12 M 1126 28465 5.693 5.280 22467 2.247 0.865 16851 1.12 0.23 11542 0.577 0.063
L 973 25931 5.186 4.401 20548 2.055 0.728 15519 1.04 0.19 10679 0.534 0.055
30
RAC
MODELS LAYOUTS
Ceiling Basic Models
(Galvanized Steel) (CB)
RE RE
TUR TU
N RN
9.4 [239] L 9.4 [239] 0 L
0.6 [1 .6 [1
5] 5]
6.7 [170]
SUP A
PLY
W
SUP A
PLY
W
Model L A W
CB 4 27.2 [691] 23.6 [599] 36.3 [922]
CB 5,6 37.2 [945] 33.7 [856] 46.3 [1176]
Model L A W
CB 8 42.8 [1087] 39.3 [998] 51.9 [1318]
CB 2,3 27.2 [691] 23.6 [599] 36.3 [922]
All dimensions are in Inch [mm]. All dimensions are in Inch [mm].
6.7 [170]
9.4 [239]
SUP A
PLY
W
Model L A W
CB 10,12 64.1 [1628] 60.6 [1539] 73.2 [1859]
31
RAC
MODELS LAYOUTS
Ceiling Basic Plenum Models
(Galvanized Steel) (CBP)
RET
URN
9.8 [249] L
0.6 [15]
19.7 [500]
0.8 [2
0]
6.7 [170]
9.4 [239]
SUP
PLY
A
W
Model L A W
CBP 2,3,4 27.2 [691] 23.6 [599] 39.0 [991]
CBP 5,6 37.2 [945] 33.7 [856] 49.0 [1245]
CBP 8 42.8 [1087] 39.3 [998] 54.6 [1387]
CBP 10,12 64.1 [1628] 60.6 [1539] 75.9 [1928]
All dimensions are in Inch [mm].
RN
TU
RE
A
FRONT VIEW
11.4 [290]
11.8 [300] ]
[130
5.1
25.2 [640]
L
22.4 [569] PLY RIGHT-SIDE VIEW
SUP
TOP VIEW
Model L A B LEGEND
GCC 2,3,4 40.5 [1029] 36.9 [937] 1.85 [47] 1 Flexible conduit
GCC 5,6 50.0 [1270] 46.9 [1191] 1.5 [38] 2 Air vent
GCC 8 56.3 [1430] 52.5 [1334] 1.9 [48] 3 Mounting holes
GCC 10,12 72.4 [1839] 68.7 [1745] 1.85 [47] 4 Coil outlet
5 Coil inlet
6 Drain connection
32
22
RAC
MODELS LAYOUTS
Floor Cabinet Models Floor Basic Models
(Galvanized Steel) (GFC) (Galvanized Steel) (FB)
PPLY 4.9 [1
2 5]
L SU W
9.8 [249]
9.8 [249] SUP
PLY
4.9 [1
2 5]
2[50]
5.9 [150]
25.8 [655]
25.8 [655]
URN
RET RET
UR N
Model L
GFC 2,3,4 43.3 [1100] Model L A W
GFC 5,6 52.7 [1339] FB 2,3,4 33.1 [841] 23.2 [589] 39.8 [1011]
GFC 8 59.1 [1501] FB 5,6 42.8 [1087] 33.1 [841] 49.5 [1257]
GFC 10,12 74.2 [1885] FB 8 50.4 [1280] 40.1 [1019] 57.1 [1450]
FB 10,12 65.6 [1666] 55.7 [1415] 72.3 [1836]
4 1
3
22.6 [574]
2
FRONT VIEW RIGHT-SIDE VIEW
6
5
1
4
3
2 3.1 [79]
LEGEND
Air vent
Drain pan
Coil outlet
Coil inlet
Drain connection
All dimensions are in Inch [mm]. All dimensions are in Inch [mm].
33
RAC
MODELS LAYOUTS
Floor Cabinet Models Ceiling Cabinet Models
(Deluxe Models) (PFC) (Deluxe Models) (PCC)
PLY L
SUP
Model L 8.9
PFC 2,3,4,5 40.6 [1031] [226]
25 [635] PLY
25 [635] SUP
RN
TU
RE
L
RN
RETU 3.1 [79]
Model L
PCC 2,3,4,5 40.6 [1031]
8.9 [226] PCC 6,8 53.5 [1359]
PCC 10,12 66.5 [1689]
All dimensions are in Inch [mm]. All dimensions are in Inch [mm].
34
RAC
PETRA HIGH WALL CHILLED WATER (PWC)
Unit Dimensions and Components
PWC 12
8.3” 39”
12”
PWC 18 + PWC 24
PWC 30 +36
PWC 12 220-240/1/50 OR 60 ½ 37
PWC 18 220-240/1/50 OR 60 ½ 40
PWC 24 220-240/1/50 OR 60 ½ 42
PWC 30 220-240/1/50 OR 60 ¾ 43
PWC 36 220-240/1/50 OR 60 ¾ 43
35
RAC
PERFORMANCE TABLE FOR (PWC)
All data are based on: AFR : Air Flow Rate (CFM).
• Entering water temperature 45OF Fan Speed : (L: Low, M: Medium, H: High).
• Interpolation is permissible but not extrapolation. DBT : Entering Dry Bulb Temperature (OF).
T.CAP : Total Cooling Capacity in (BTUH).
S.CAP : Sensible Cooling Capacity in (BTUH).
WFR : Water Flow Rate In GPM.
WPD : Water Pressure Drop in (ft of water).
36
RAC
ELECTRICAL DATA TABLES
RAC 2
RAC 3
RAC 4
RAC 5
RAC 6
RAC 8
RAC 10
RAC 12
• MCA is based on 125% of the RLA for the largest FLA : Full Load Ampere [for each fan motor].
motor plus 100% of the RLA/FLA for MCA : Minimum Circuit Ampacity.
all other loads included in the circuit (NEC-Article 430-24). MOP : Maximum Overcurrent Protection.
37
RAC
SOUND POWER LEVEL dB
Discharge Sound Power Level (Reference To SWL Pico Watt)
Fan Total
MODEL Frequency Band (Hz)
Speed dB(A)
63 125 250 500 1K 2K 4K 8K
L 40 42 44 36 32 25 25 18 39
RAC 2 M 42 44 46 40 36 29 29 22 42
H 44 46 48 44 40 33 33 26 45
L 41 43 44 37 35 27 28 18 40
RAC 3 M 43 45 46 41 39 31 32 22 43
H 45 47 48 45 43 35 36 26 47
L 42 43 44 38 36 29 29 19 41
RAC 4 M 44 45 46 42 40 33 33 23 44
H 46 47 48 46 44 37 37 27 48
L 45 45 46 39 39 32 30 22 43
RAC 5 M 47 47 48 43 43 36 34 26 43
H 49 49 50 47 47 40 38 30 50
L 47 47 48 41 40 34 33 23 45
RAC 6 M 49 49 50 45 44 38 37 27 48
H 51 51 52 49 48 42 41 31 52
L 48 49 51 43 42 35 33 24 47
RAC 8 M 50 51 53 47 46 39 37 28 50
H 52 53 55 51 50 43 41 32 54
L 51 51 54 46 45 37 36 25 50
RAC 10 M 53 53 56 50 49 41 40 29 53
H 55 55 58 54 53 45 44 33 57
L 51 52 55 46 47 37 35 26 51
RAC 12 M 53 54 57 50 51 41 39 30 54
H 55 56 59 54 55 45 43 34 58
Heating Capacity
MODEL
[kW]
RAC 2 1.50
RAC 3 1.50
RAC 4 2.50
RAC 5 3.00
RAC 6 3.00
RAC 8 4.00
RAC 10 6.00
RAC 12 6.00
38
RAC
WIRING DIAGRAMS
3 Speed Selector Switch
39
RAC
WIRING DIAGRAMS
3-way Valve (cooling) With Electric
Heater ( Option)
40
RAC
WIRING DIAGRAMS
3-way Valve cooling/heating With
Electric Heater(Option)
41
RAC