Compressor Technical Data Sheet
Compressor Technical Data Sheet
4 IMD
Product definition
Model ZR 160 VSD STD
Pressure variant 10.4 bar
Integrated dryer IMD dryer
Frequency 50 Hz
Reference conditions
Absolute inlet pressure 1 bar(a)
Relative humidity 0%
Air inlet temperature 20 °C
Cooling water inlet temperature 20 °C
Cooling water temperature rise 10 °C
Effective working pressure 9 bar(g)
Motor shaft speed(rpm) 3490 rpm
Performance data*1
Maximum working pressure 10.4 bar(g)
Free air delivery ( at maximum volume flow rate ) 356.9 l/s
− Total electrical power input 164.1 kW
− Total specific energy requirements (SER) 459.8 J/l
Free air delivery (at 75% of volume flow range) 315.9 l/s
− Total electrical power input 144.1 kW
− Total specific energy requirements (SER) 456.1 J/l
Free air delivery (at 50% of volume flow range) 274.8 l/s
− Total electrical power input 125.6 kW
− Total specific energy requirements (SER) 457.1 J/l
Free air delivery (at 25% of volume flow range) 233.8 l/s
− Total electrical power input 107.8 kW
− Total specific energy requirements (SER) 461.2 J/l
Free air delivery ( at minimum volume flow rate ) 192.8 l/s
− Total electrical power input 90.6 kW
− Total specific energy requirements (SER) 470.2 J/l
Effective working pressure 9 bar(g)
− Free air delivery ( at maximum volume flow rate ) 373.4 l/s
− Total electrical power input 162 kW
− Total specific energy requirements (SER) 433.9 J/l
− Free air delivery (at 75% of volume flow range) 321.7 l/s
− Total electrical power input 137.2 kW
− Total specific energy requirements (SER) 426.6 J/l
− Free air delivery (at 50% of volume flow range) 270 l/s
− Total electrical power input 115.2 kW
− Total specific energy requirements (SER) 426.6 J/l
− Free air delivery (at 25% of volume flow range) 218.3 l/s
− Total electrical power input 94.1 kW
− Total specific energy requirements (SER) 431.4 J/l
− Free air delivery ( at minimum volume flow rate ) 166.6 l/s
− Total electrical power input 74.2 kW
− Total specific energy requirements (SER) 445.5 J/l
Minimum effective working pressure 6 bar(g)
Free air delivery ( at maximum volume flow rate ) 373.6 l/s
− Total electrical power input 139 kW
− Total specific energy requirements (SER) 372 J/l
Free air delivery (at 75% of volume flow range) 322 l/s
− Total electrical power input 116.9 kW
− Total specific energy requirements (SER) 363.2 J/l
Free air delivery (at 50% of volume flow range) 270.3 l/s
− Total electrical power input 97.4 kW
− Total specific energy requirements (SER) 360.3 J/l
Free air delivery (at 25% of volume flow range) 218.7 l/s
− Total electrical power input 78.9 kW
− Total specific energy requirements (SER) 361 J/l
Free air delivery ( at minimum volume flow rate ) 167 l/s
− Total electrical power input 61.6 kW
− Total specific energy requirements (SER) 368.7 J/l
Unit data*4
Compressed air temperature at outlet 28 °C
Mean sound pressure level*2 71 dB(A)
Cooling water flow 3.4 l/s
Cooling water pressure drop 247.3 mbar
Cooling air flow motor 0.5 m³/s
Cooling air flow frequency converter 0.4 m³/s
Oil capacity 37 l
Limitations
Maximum effective working pressure 10.4 bar(g)
Minimum effective working pressure 6 bar(g)
Maximum ambient temperature 40 °C
Minimum ambient temperature 0 °C
Maximum cooling water outlet temperature*3 50 °C
Maximum cooling water inlet temperature*3 40 °C
Minimum cooling water inlet temperature*3 0 °C
Maximum altitude (above sea level) 1000 m
Installation connections
Compressed air outlet DN80-PN16
Cooling water (inlet/outlet) DN40-PN16
Condensate drain connections G 1/2"
Electrical cable entry size M63
Frequency Converter
Converter manufacturer NEOS E
Electrical data
Supply voltage 400 V
Supply frequency 50 Hz
Package current*6 277.6 A
Electrical network TT or TN network
Approvals
Electrical approval IEC
Pressure vessel approval CE
Notes
*1 The FAD figures quoted correspond to 'Actual Volume Flow Rate' in accordance with ISO 1217
Ed. 4 (2009), guaranteed with a tolerance of +/-5 % for FAD < 250 l/s (530 cfm) or +/-4 % for FAD >
250 l/s (530 cfm).
FAD (Free Air Delivery) is measured at the above stated reference conditions.
The FAD figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply
voltages > 1kV
*1 The SER figures quoted are in accordance with ISO 1217 Ed. 4 (2009),
guaranteed with a tolerance of +/-6 % for FAD < 250 l/s (530 cfm) or +/-5 % for FAD > 250 l/s (530
cfm).
The SER figures are valid for supply voltage 400V (for 50Hz-units) or 460V (for 60Hz-units).
Data may differ 0,5% maximum at other supply voltages < 1kV and 3,5% maximum at supply
voltages > 1kV
*5 The inverter and motor together comply with the requirements for power drive efficiency
(according to IEC 61800-9-2 & EN 50598)
*7 The pre-described fuses OR circuit breaker are maximum main fuses or circuit breaker to protect
the installed compressor electrical panel.
Cable and fuse or circuit breaker selection will depend on customer’s installation.
Fuses or circuit breaker of the same type/class are mandatory. Not installing these fuses or circuit
breaker will void warranty in case of an electrical failure.
Installing smaller fuses might lead to smaller supply cables. If Main circuit breaker shown as NA
(not applicable), only fuses are allowed.