Flanking transmission is a term used by acoustical engineers wherein the sound passes around, over the top or
under the primary partition separating two spaces. Flanking sound transmission can be especially bothersome
in multi-family residential buildings. The best time to guard against flanking transmission is in the design and
construction phase of the dwelling. Simply specifying a high performance wall between adjacent dwelling spaces
is no guarantee to sound isolation and privacy upon occupancy. Acoustical Surfaces Inc., offer both
preconstruction and post construction noise control consultations in addition to all of the products needed to
achieve demanded sound isolation.
Buyers of town houses, condominiums and other multi-family residences should not refrain from asking
questions about the sound isolation characteristics of their new dwelling. Furthermore they should inspect their
proposed dwelling during the construction phase to make sure that the quality of the workmanship is consistent
with good noise control procedures. After all, a new home will be one of the most expensive investments a
person or couple will make in their lifetime.
Ask the architect or the builder what steps have been taken to insure sound privacy from your future neighbors
or from noise intrusion from outside the building. Do not assume that just because the architect has specified
high performance walls, windows and floor/ceiling assemblies that the materials and workmanship will result in
compliance with the anticipated results. Ultimately sound isolation in your home may be contingent on the
workman installing the materials on the job who, for all his pride in the quality of his workmanship, may know
little or nothing about fundamental noise control techniques unless he is give the right supervision and
direction.
Most building codes have minimum standards for noise control between residential dwelling units. Upon
completion of the building the Building inspection department may be required to issue a certificate of
occupancy, which implies that the building meets minimum building code standards including sound isolation.
Many building inspectors are not conversant with noise control techniques and their inspection departments do
not enforce the need for validation. It is no wonder that horror stories abound by residence owners and
apartment dwellers who can easily hear the activities of their neighbors. By then there is no easy or inexpensive
fix. An ounce of prevention by contacting Acoustical Surfaces Inc., ahead of time can save a great deal of
heartache and expense later on.
The STC rating of a floor/ceiling assembly or a wall is a single number rating that stands for Sound Transmission
Class. The higher the STC rating, the better the sound isolation characteristics of the assembly will be. Most
building codes require a minimum design for floors and wall construction to have an STC rating of 50 but will
accept a minimum of 45 by actual field-testing. One thing that all walls have in common when they are tested in
the acoustical laboratory is that they are all caulked or otherwise sealed into the test opening. Therefore what
ever is done in the test lab should be replicated as close as possible on the construction site. When the
construction assembly is tested in the lab it is also certified and an exact description of the materials and the
installation techniques are described in detail. These too should be replicated on the job site as close as
possible. However, it is not always possible to replicate the exact conditions on the jobsite compared to the ideal
conditions normally present in a lab setting, which is the reason why a 5 point difference is allowed between the
construction design on paper and the actual on site performance.
The method by which the STC is arrived at also takes into consideration as to how we actually perceive sounds.
Our sense of hearing isles sensitive to low frequency sounds and thus the STC curve takes that into
consideration at the various frequencies.
Another little known fact about sound is that unless it is passing through an obvious crack or leak, sound does
not pass through a wall. Rather the sound energy sets the wall in motion and the wall itself becomes the
transmitter much like a radio wave that energizes a radio speaker, which transmits the broadcast signal. The
materials that comprise the wall and the manner in which they are installed can have a great bearing on the
performance of the wall. Many innovative methods are used to construct walls and floors. For wall assemblies
the best sources of design information is through Acoustical Surfaces, Inc.
Whether noise control is accomplished during initial construction as an after occupancy problem or during the
process of renovation, Acoustical Surfaces, Inc., has the products and the technical experience to help identify
and STOP your acoustical, soundproofing or noise control problem.
Additional Resources
Creating Better- Solutions to Common
Sounding Rooms Noise Problems CAD, CSI, & Revit Library
Download eBook
Download eBook Access Product Cad Files
(//soundproofing.acousticalsurfaces.com/common-
(//soundproofing.acousticalsurfaces.com/download- (//soundproofing.acousticalsurfaces.com
noise-problems-ebook)
our-ebook-creating-better- our-cad-csi-revit-library)
sounding-rooms-is-easier-than-
you-think)