Manual Hyu Ac Sask2em001
Manual Hyu Ac Sask2em001
HYU-AC-SASK2EM001
1
INTRODUCTION
The device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable
performance. The operation is very user-friendly, and low-power circuit makes it long service life.
The device supports 1,000 users (998 common users + 2 panic users), all user data can be transferred from one to another (Max 10pcs). It
supports multi access modes in either card access, PIN access, Card + PIN access, or multi cards/PINs access. It has extra features including
block enrollment, interlocked, Wiegand 26~37 bits interface…etc.
Features
Specifications
Carton Inventory
Diode IN4004 (For
relay circuit protection)
Wall Anchors
Self Tapping
Screws: Φ4*25mm
Screw Driver
INSTALLATION
Wall
.2
φ3mm
9.5mm
A
X4mm
φ5
41.5mm
70mm
B
mm
φ9
C
9.5mm
Step2 Step1
Step3
Wiring
Basic Configure
Enter and Exit Program mode
Programming Step Keystroke Combination
(Master Code) #
Enter Program Mode
(Factory default is 123456)
Exit Program Mode
STANDALONE MODE
The device can be worked as Standalone Reader for single door.
(Factory default mode)---7 2 #
Connection Diagram
Blue
NO
- K-
Orange Magnetic
NC
In4004
In4004
Lock or Fail-secure
Fail-Safe lock
Purple Lock
COM
+ K+
GND
Red
DC+ +12~18V
Exit Button
Yellow
OPEN Power Supply
Brown
D_IN
Door Contact +
Grey
ALARM- -
Green Alarm
D0
White
D1
Black
GND
Access Control
Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or
the keypad might be damaged. (1N4004 is included in the packing)
6
Blue
NO
Orange
NC
Purple
COM PUSH
GND
Red
DC+ +12V
Exit Button
Yellow
DC Alarm lock K+
Green
D0
White
D1
Black
GND
Access Control
Programming
Programming will vary depending on access confirguration. Follow the instructions according to your access
configuration.
>Notes:
PIN: Can be any 4~6 digits except 8888 which is reserved.
> User ID number: Assign a user ID to the access card / PIN in order to track it. The common user ID number can be any number fom 0~997, the panic user
ID is from 998~999. IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID is critical. Modifications to the user
require the User ID be available. Proximity Card :
EM version: 125 KHz industry standard 26bits EM card
HID & EM version: 125 KHz industry standard 26bits HID & EM cards
>
7
Delete Users
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
Delete Card User - Common
2. Delete Card – By Card 2 (Read Card) #
OR The cards can be deleted continuously.
2. Delete Card – By ID number 2 (User ID ) #
OR
2. Delete User – By Card number 2 (Input 8/10 digits Card number) #
Delete PIN User - Common
2. Delete PIN – by PIN 2 (Input PIN) #
OR
2. Delete PIN – By ID number 2 (User ID ) #
Delete Panic User
2. Delete Panic Card User 2 (User ID ) #
OR
2. Delete Panic PIN User 2 (User ID ) #
Delete All Users
Delete All User 2 (Master Code) #
3. Exit
9
Simplified Instruction
Function Description Operation
- 123456 - #
then you can do the programming
Enter the Programming Mode
(123456 is the factory default master
code)
0 - new code - # - repeat the new
Change the Master Code code - #
(code: 6 digits)
1 - Read Card - #
Add Card User (can add Cards continuously)
Add PIN User 1 - PIN - #
2 - Read Card - # for Card User
Delete User
2 - PIN - # for PIN user
Exit from the programming Mode
How to release the door
Card User Read Card
PIN User Input PIN #
11
Programming Keystroke
Step
1. Enter Program Combination
(Master Code)
Mode #
2.Strike-Out OFF 6 0 # (factory default)
OR
2. Strike-Out 6 1 # Access will be denied for 10
O
ON minutes
R
2. Strike-Out ON
(Alarm) 62#
Set alarm 5 (0 ~ 30) # (factory default is 1
minute) Enter Master code # or valid
time
user card /PIN to silence
3.
Exit
Set Audible and Visual
Response
Programming Keystroke
Step
1. Enter Program Combination
(Master Code)
Mode #
2.Control Sounds OFF = 7 0 ON = 7 1
OR # #
2. Control OFF = 7 4 ON = 7 5
O
LED # #
R
2.Control Keypad OFF = 7 6 ON = 7 7
Backlit # (#Factory defaults are
ON)
3.
Exit
Set Card Reading Type (This step can only be applied to HID & EM
version)
Programming Keystroke
Step
1. Enter Program Combination
(Master Code)
Mode #
2. ReadHID & car 9 3 # (factory
OR EM d default)
2. Read EM card 94
ONLY OR #
2. Read HID card 95
ONLY
3. #
Exit
8
2. (Read User Card) / (Input User PIN #) Repeat Step 2 for additional user cards /
Add a User PINs
2. (Read User Card) / (Input User PIN #) Repeat Step 2 for additional user cards/ PINs
Delete a User 3. (Read Master Delete Card)
> To reset to factory default & Add Master Cards: power off, press the Exit Button, hold it and power on, there will be two
beeps, and the LED light turns into yellow, release the exit button, then read any two 125KHz EM cards or HID cards, the
LED will turn into red, means reset to factory default successfully. Of the two cards reading, the 1st one is Master Add Card,
the 2nd one is the Master Delete Card. Remarks:
① If no Master Cards added, must press the Exit Button for at least 10 seconds before
release.
② Reset to factory default, the user’s information is still retained.
CONTROLLER MODE
The device can work as Controller, connected with the external Wiegand reader. (Factory
default mode)---7 2 #
Connection Diagram
Blue
NO PUSH
Orange
NC GND
Purple
COM +12V
lock K+
Brown
D_IN
Door Contact +
Grey
ALARM- GND
-
DC Alarm
Green
D0 +12V
White
D1 D0
Black
GND D1
Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is
included in the packing)
3. Exit
Programming
- If EM card reader or HID card reader: users can be added/deleted on either the device
or external reader.
- If Mifare reader: users can only be added/deleted on external reader.
The device connected with Fingerprint Reader:
For example:
Connect F1 as the fingerprint reader to the device, it is of two steps to enroll the valid fingerprint.
Step 1: Add the Fingerprint (A) on F1
Step 2: Add the same Fingerprint(A) on the device:
2
1 (Press Fingerprint A once on F1) # (ID auto allocated)
or
1 (User ID) # (Press Fingerprint A on F1) # (Select specific ID)
2
3 Exit:
3. Exit
Notes:
The EM version reads EM card only, while the HID & EM version can be set to read HID & EM cards, or HID card only, or EM card
only. Factory default card type of the HID & EM card, if you want to change the type, please set the device to Standalone Mode (7 2 #)
and then set the type. (See page 11 for setting card type).
Connection Diagram
Red
+12V
Black
GND
Green
D0
White
D1
Brown
LED
Yellow
BZ
Access Controller
Reader
Notes:
> When set into Wiegand Reader mode, nearly all settings in Controller Model will
become invalid. And Brown & Yellow wires will be redefined as below:
- Brown wire: Green LED light control
- Yellow wire: Buzzer control
Power
+ DC
GND
Red
Black
Green(D0)
White(D1)
Remarks:
> The Master units and Accept units must be the same device or device with same function.
> The Master Code of the Master Unit(s) and the Accept Unit(s) must be set to the same.
> Program the transfer operation on Master Unit only.
> If the Accept Unit(s) are already with the users enrolled, it will be covered after transferring.
> For full 1000 users enrolled, the transfer takes 3 minutes.
3. Exit
Interlock
The device supports the Interlock funciton. It is of two keypads for two doors,
and mainly used for banks, prisons, and other places where a higher level
security is required.
DC Power Supply
Connection Diagram:
+12~18V
GND
Blue Blue
NO NO
- K- K- -
Orange Magnetic Magnetic Orange
NC NC
In4004
In4004
In4004
In4004
Lock or Fail-secure Fail-secure Lock or
Fail-Safe lock lock Fail-Safe
Purple Lock Lock
Purple
COM COM
+ K+ K+ +
Red Red
DC+ DC+
Exit Button Exit Button
Yellow Yellow
OPEN OPEN
Grey Grey
ALARM- ALARM-
Green Green
D0 D0
White White
D1 Door Contact Door Contact D1
Black Black
GND GND
Brown Brown
D_ IN D_ IN
Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Keypads as “A “and “B” for two doors “1” and “2”
Step 1:
Enroll the users on Keypad A, then transfer the users’ information to Keypad B
by ”User Information Transfer” funciton.
Step 2:
Set both of the two Keypads (A and B) to Interlock function
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
2. Interlocked-OFF 9 0 # (factory default)
OR
2. Interlocked-ON 91#
3. Exit