DIGITAL DOOR LOCK

HYU-AC-SASK2EM001
1

INTRODUCTION
The device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable
performance. The operation is very user-friendly, and low-power circuit makes it long service life.

The device supports 1,000 users (998 common users + 2 panic users), all user data can be transferred from one to another (Max 10pcs). It
supports multi access modes in either card access, PIN access, Card + PIN access, or multi cards/PINs access. It has extra features including
block enrollment, interlocked, Wiegand 26~37 bits interface…etc.

Features

> Waterproof, conforms to IP66


> One relay, keyboard programmer
> 1,000 users (998 common users + 2 panic users)

> Wiegand 26~37 bits input & output


> Can be used as Wiegand reader with LED & buzzer output
> Card block enrolment
> Tri-colour LED status display

> Pulse mode, Toggle mode

> 2 devices can be interlocked for 2 doors


>
> Built in light dependent resistor (LDR) for anti tamper
>>Backlit keypad
> Low temperature resistance(-40℃ )

PIN length: 4~6 digits


Card type:
EM version: 125KHz EM card
HID & EM version: 125KHz HID & EM cards

> Integrated alarm & buzzer output

> User data can be transferred

Specifications

User Capacity 1000


Common User 998
Panic User 2

Operating Voltage 12~18V DC

Idle Current <35mA


2

Proximity Card Reader EM or HID & EM


Radio Technology 125KHz Proximity Card
Read Range 2~6 cm
Relay Output, Exit Button, Alarm, Door
Wiring Connections
Contact, Wiegand Input, Wiegand Output
Relay One (NO, NC, Common)
Adjustable Relay Output Time 1~99 Seconds (5 seconds default)
Lock Output Load 2 Amp Maximum
Wiegand Interface Wiegand 26-37 bits
Wiegand Input 26-37 bits
Wiegand Output 26-37 bits
PIN Output 4 bits, 8 bits(ASCII), 10 digits Virtual Number
Environment Meets IP66
Operating Temperature -40℃ ~ 60℃ (-40℉ ~ 140℉)
Operating Humidity 0~98%RH
Physical ABS Shell
Colour Black
Dimensions L122mm × W50mm × D21mm
Unit Weight 165g
Shipping Weight 260g

Carton Inventory
Diode IN4004 (For
relay circuit protection)

Wall Anchors

Self Tapping
Screws: Φ4*25mm

Screw Driver

Master Add Card Master Delete Card Master Cards


Access Controller / Reader
3

INSTALLATION

> Remove the back cover from the unit


> Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
> Knock the supplied rubber bungs to the screw holes(A,C)
> Fix the back cover firmly on the wall with 4 flat head screws
> Thread the cable through the cable hole(B)
> Attach the unit to the back cover

Wall

.2
φ3mm

9.5mm
A
X4mm
φ5

41.5mm

70mm
B
mm
φ9

C
9.5mm

Step2 Step1

Step3

Wiring

Wire Color Function Notes

Basic Standalone Wiring

Red DC + 12-18V DC Power Input

Black GND Negative Pole of DC Power Input

Blue Relay NO Normally Open Relay Output (install diode provided)

Purple Relay Common Common Connection for Relay Output


4

Orange Relay NC Normally Closed Relay Output (Install diode provided)


Yellow OPEN Request to Exit(REX) Input
Pass-Through Wiring (Wiegand Reader or Controller)
Green Data 0 Wiegand Output (Pass-through) Data 0
White Data 1 Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey Alarm Output Negative contact for Alarm
Brown Contact Input Door/Gate Contact Input (Normally Closed)

Sound and Light Indication


Operation Status LED Buzzer
Stand by Red light bright
Enter into programming mode Red light shines One beep
In the programming mode Orange light bright One beep
Operation error Three beeps
Exit from the programming mode Red light bright One beep
Open lock Green light bright One beep
Alarm Red light Shines quickly Beeps

Basic Configure
Enter and Exit Program mode
Programming Step Keystroke Combination
(Master Code) #
Enter Program Mode
(Factory default is 123456)
Exit Program Mode

Set Master Code


Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
0 (New Master Code) # (Repeat New
2. Update Master Code Master Code) #
(Master code is any 6 digits)
3. Exit Program Mode
5

Set the Working Mode


Notes: the device has 3 working modes: Standalone Mode, Controller Mode, Wiegand
Reader Mode, choose the mode you use. (Factory default is Standalone Mode /
Controller Mode)
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
2. Standalone/Controller Mode 7 2 # (Factory default)
OR
2. Wiegand Reader Mode 73#
3. Exit

STANDALONE MODE
The device can be worked as Standalone Reader for single door.
(Factory default mode)---7 2 #

Connection Diagram

Blue
NO
- K-
Orange Magnetic
NC
In4004
In4004

Lock or Fail-secure
Fail-Safe lock
Purple Lock
COM
+ K+

GND
Red
DC+ +12~18V
Exit Button
Yellow
OPEN Power Supply
Brown
D_IN
Door Contact +
Grey
ALARM- -
Green Alarm
D0
White
D1
Black
GND

Access Control

Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or
the keypad might be damaged. (1N4004 is included in the packing)
6

Access Control Power Supply:

Blue
NO

Orange
NC

Purple
COM PUSH

GND

Red
DC+ +12V
Exit Button
Yellow

Special Power Supply


OPEN Magnetic NC
Lock or
+
Brown Fail-Safe
GND
D_IN -
Lock
COM
Door Contact +
Grey
ALARM- K- NO
- Fail-secure

DC Alarm lock K+
Green
D0

White
D1

Black
GND

Access Control

Programming
Programming will vary depending on access confirguration. Follow the instructions according to your access
configuration.

>Notes:
PIN: Can be any 4~6 digits except 8888 which is reserved.

> User ID number: Assign a user ID to the access card / PIN in order to track it. The common user ID number can be any number fom 0~997, the panic user
ID is from 998~999. IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID is critical. Modifications to the user
require the User ID be available. Proximity Card :
EM version: 125 KHz industry standard 26bits EM card
HID & EM version: 125 KHz industry standard 26bits HID & EM cards

>
7

Add Common Users


Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
Add Card User
2. Add Card: Using Auto ID 1 (Read Card) #
(Allows the device to assign Card to The cards can be added continuously.
next available User ID number)
OR
2. Add Card: Select Specific ID 1 (User ID) # (Read Card) #
(Allows Master to define a specific (User ID is any number from 0~997)
User ID to associate the card to)
OR
2. Add Card: by Card Number 1 (Input 8/10 digits Card number) #
OR
2. Add Card: Block Enrolment 1 ( User ID ) # (Card quantity)
(Allows Master to add up to 998 cards # (The first card number) #
to the Reader in a single step) Takes Cards' number must be consecutive;
2 minutes to program. Card quantity = number of cards to be
enrolled.
Add PIN User
2. Add PIN: Using Auto ID 1 (PIN ) #
(Allows the device to assign PIN to The PINs can be added continuously.
next available User ID number) (PIN: 4~6 digits)
2. Add PIN: Select Specific ID 1 (User ID) # (PIN ) #
(Allows manager to define a specific The user ID is any number from 0~997.
User ID to associate the PIN to)
3. Exit

Add Panic Users


Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
2. Add Card: 1 (User ID) # (Read Card / Input 8/10
OR digits Card number) #
2. Add PIN: 1 (User ID) # (PIN ) #
(User ID is any number from 998~999)
3. Exit
8

Change PIN Users


Programming Step Keystroke Combination
Note: Below is done outside programming mode, users can undertake this
themselves
2. Change PIN: By Card (There will (Read Card) (Old PIN) # (New PIN) #
auto allocate PIN (8888) to cards (Repeat New PIN) #
when adding)
2. Change PIN: By PIN (User ID) # (Old PIN) # (New PIN) #
(Repeat New PIN) #
3. Exit

Delete Users
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
Delete Card User - Common
2. Delete Card – By Card 2 (Read Card) #
OR The cards can be deleted continuously.
2. Delete Card – By ID number 2 (User ID ) #
OR
2. Delete User – By Card number 2 (Input 8/10 digits Card number) #
Delete PIN User - Common
2. Delete PIN – by PIN 2 (Input PIN) #
OR
2. Delete PIN – By ID number 2 (User ID ) #
Delete Panic User
2. Delete Panic Card User 2 (User ID ) #
OR
2. Delete Panic PIN User 2 (User ID ) #
Delete All Users
Delete All User 2 (Master Code) #
3. Exit
9

Set Relay Configuration


The relay configuration sets the behaviour of the output relay on activation.

Programming Step Keystroke Combination


1. Enter Program Mode (Master Code) #
2. Pulse Mode 3 (1-99) # (factory default)
The relay time is 1-99 seconds.
OR (1 is 50mS.) (Default is 5 seconds)

2. Toggle Mode 30#


Sets the relay to ON/OFF Toggle mode
3. Exit

Set Access Mode


For Multi cards/PINs access mode, the interval time of reading cards/inputting PINs can
not exceed 5 seconds, or else, the device will exit to standby automatically.

Programming Step Keystroke Combination


1. Enter Program Mode (Master Code) #
2. Card access 40#
OR
2. Card + PIN access 41#
OR
2. Card or PIN access 42#
OR
2. Multi cards/PINs access 4 3 (2~9) #
(Only after reading 2~9 cards or inputting
2~9 PINs, the door can be opened)
3. Exit
10

Simplified Instruction
Function Description Operation
- 123456 - #
then you can do the programming
Enter the Programming Mode
(123456 is the factory default master
code)
0 - new code - # - repeat the new
Change the Master Code code - #
(code: 6 digits)
1 - Read Card - #
Add Card User (can add Cards continuously)
Add PIN User 1 - PIN - #
2 - Read Card - # for Card User
Delete User
2 - PIN - # for PIN user
Exit from the programming Mode
How to release the door
Card User Read Card
PIN User Input PIN #
11

Set Strike-out Alarm


The strike-our alarm will engage after 10 failed entry attempts (Factory is
OFF). It can be set to deny access for 10 minutes after engaging or
disengage only after entering a valid card/PIN or Master code.

Programming Keystroke
Step
1. Enter Program Combination
(Master Code)
Mode #
2.Strike-Out OFF 6 0 # (factory default)
OR
2. Strike-Out 6 1 # Access will be denied for 10
O
ON minutes
R
2. Strike-Out ON
(Alarm) 62#
Set alarm 5 (0 ~ 30) # (factory default is 1
minute) Enter Master code # or valid
time
user card /PIN to silence
3.
Exit
Set Audible and Visual
Response
Programming Keystroke
Step
1. Enter Program Combination
(Master Code)
Mode #
2.Control Sounds OFF = 7 0 ON = 7 1
OR # #
2. Control OFF = 7 4 ON = 7 5
O
LED # #
R
2.Control Keypad OFF = 7 6 ON = 7 7
Backlit # (#Factory defaults are
ON)
3.
Exit

Set Card Reading Type (This step can only be applied to HID & EM
version)
Programming Keystroke
Step
1. Enter Program Combination
(Master Code)
Mode #
2. ReadHID & car 9 3 # (factory
OR EM d default)
2. Read EM card 94
ONLY OR #
2. Read HID card 95
ONLY
3. #
Exit
8

Master Cards Usage

Using Master Cards to add and delete card / PIN users

1. (Read Master Add Card)

2. (Read User Card) / (Input User PIN #) Repeat Step 2 for additional user cards /
Add a User PINs

3. (Read Master Add Card)

1. (Read Master Delete Card)

2. (Read User Card) / (Input User PIN #) Repeat Step 2 for additional user cards/ PINs
Delete a User 3. (Read Master Delete Card)

Users Operation & Reset to Factory Default


> Open the door: Read valid user card or inputting valid user PIN
> Remove Alarm: Read valid user card or inputting valid user PIN, or input
Master Code #

> To reset to factory default & Add Master Cards: power off, press the Exit Button, hold it and power on, there will be two
beeps, and the LED light turns into yellow, release the exit button, then read any two 125KHz EM cards or HID cards, the
LED will turn into red, means reset to factory default successfully. Of the two cards reading, the 1st one is Master Add Card,
the 2nd one is the Master Delete Card. Remarks:

① If no Master Cards added, must press the Exit Button for at least 10 seconds before
release.
② Reset to factory default, the user’s information is still retained.

CONTROLLER MODE
The device can work as Controller, connected with the external Wiegand reader. (Factory
default mode)---7 2 #
Connection Diagram
Blue
NO PUSH

Orange
NC GND

Purple
COM +12V

Special Power Supply


Magnetic NC
Lock or
+
Red Fail-Safe
GND
-
DC+ Lock
COM
Exit Button
Yellow
OPEN K- NO
Fail-secure

lock K+
Brown
D_IN
Door Contact +
Grey
ALARM- GND
-
DC Alarm
Green
D0 +12V

White
D1 D0

Black
GND D1

Access Control Reader

> Basic Programming is the same as Standalone Mode


> There are some exceptions for your attention:
The device connected with Enternal Card Reader:

Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is
included in the packing)

Set Wiegand Input Formats


Please set the Wiegand input formats according to the Wiegand output format of the external Reader.

Programming Step Keystroke Combination

1. Enter Program Mode (Master Code) #

2. Wiegand intput bits 8 (26~37) # (factory default is 26 bits)

3. Exit

Programming

- If EM card reader or HID card reader: users can be added/deleted on either the device
or external reader.
- If Mifare reader: users can only be added/deleted on external reader.
The device connected with Fingerprint Reader:
For example:
Connect F1 as the fingerprint reader to the device, it is of two steps to enroll the valid fingerprint.
Step 1: Add the Fingerprint (A) on F1
Step 2: Add the same Fingerprint(A) on the device:

1 Enter Program Mode: (Master Code) #

2
1 (Press Fingerprint A once on F1) # (ID auto allocated)
or
1 (User ID) # (Press Fingerprint A on F1) # (Select specific ID)
2

3 Exit:

The device connected with Keypad Reader:


The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output format. Choose the below operation according to the PIN
output format of your reader.

Programming Step Keystroke Combination

1. Enter Program Mode (Master Code) #

2. Wiegand input bits 8 (4 or 8 or 10) # (factory default is 4 bits)

3. Exit

> Add PIN Users:


To add PIN users, after enter into programming mode on the device , PIN(s) can be input/ added on either the device controller or the
external Keypad Reader.

> Delete PIN Users: the same way as add users.

Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual number.

WIEGAND READER MODE


The device can work as Standard Wiegand Reader, connected to the third party Controller--- 7 3 #

Notes:
The EM version reads EM card only, while the HID & EM version can be set to read HID & EM cards, or HID card only, or EM card
only. Factory default card type of the HID & EM card, if you want to change the type, please set the device to Standalone Mode (7 2 #)
and then set the type. (See page 11 for setting card type).

Connection Diagram
Red
+12V
Black
GND
Green
D0
White
D1
Brown
LED
Yellow
BZ

Access Controller

Reader

Notes:
> When set into Wiegand Reader mode, nearly all settings in Controller Model will
become invalid. And Brown & Yellow wires will be redefined as below:
- Brown wire: Green LED light control
- Yellow wire: Buzzer control

> If you need to connect Brown/Yellow wires:


When the input voltage for LED is low, the LED will turn into Green; and when the
input voltage for Buzzer is low, it will sound.

Set Wiegand Output Formats


Please set the Wiegand output formats of Reader according to the Wiegand intput
formats of the Controller.
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
2. Wiegand output bits 8 (26~37) # (factory default is 26 bits)
PIN output bits 8 (4 or 8 or 10) # (factory default is 4 bits)
3. Exit
ADVANCE APPLICATION
User Information Transfer
The device supports the User Information Transfer function, and the enrolled user
(cards, PINs) can be transferred from one (let’s name it Master Unit) to another (let’s
name it Accept Unit). Maximum 10pcs accept Units can be transferred once.
Connection Diagram:

Power

+ DC

GND

Red

Black

Green(D0)

White(D1)

Remarks:

> The Master units and Accept units must be the same device or device with same function.
> The Master Code of the Master Unit(s) and the Accept Unit(s) must be set to the same.
> Program the transfer operation on Master Unit only.
> If the Accept Unit(s) are already with the users enrolled, it will be covered after transferring.
> For full 1000 users enrolled, the transfer takes 3 minutes.

Set Transferring on Master Unit:

Programming Step Keystroke Combination

1. Enter the programming mode (Master Code) #

2. Set transferring 96#


Within 3 minutes, Green LED shines, after one beep, the LED will turn into Red, which means the users’
information has been transferred successfully.

3. Exit
Interlock
The device supports the Interlock funciton. It is of two keypads for two doors,
and mainly used for banks, prisons, and other places where a higher level
security is required.
DC Power Supply

Connection Diagram:

+12~18V
GND
Blue Blue
NO NO
- K- K- -
Orange Magnetic Magnetic Orange
NC NC

In4004

In4004
In4004

In4004
Lock or Fail-secure Fail-secure Lock or
Fail-Safe lock lock Fail-Safe
Purple Lock Lock
Purple
COM COM
+ K+ K+ +

Red Red
DC+ DC+
Exit Button Exit Button
Yellow Yellow
OPEN OPEN
Grey Grey
ALARM- ALARM-
Green Green
D0 D0
White White
D1 Door Contact Door Contact D1
Black Black
GND GND
Brown Brown
D_ IN D_ IN

Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Keypads as “A “and “B” for two doors “1” and “2”

Step 1:
Enroll the users on Keypad A, then transfer the users’ information to Keypad B
by ”User Information Transfer” funciton.

Step 2:
Set both of the two Keypads (A and B) to Interlock function
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
2. Interlocked-OFF 9 0 # (factory default)
OR
2. Interlocked-ON 91#
3. Exit

The interlock operation is finished,


When and only door 2 is closed, the user can read the valid card or input PIN on
Keypad A, door 1 will open; then when and only door 1 closed, read valid card or
input PIN on Keypad B, door 2 will open.