0% found this document useful (0 votes)
38 views12 pages

Noyafa NF300 User Manual

The document provides instructions for using the NF-300 cable tester. It can test for opens, shorts, cross-connections and more. It detects cable types and measures lengths up to 2500m. The tester is composed of a main unit, receiver, and remote identifier to trace cables without interference.

Uploaded by

guecorandy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views12 pages

Noyafa NF300 User Manual

The document provides instructions for using the NF-300 cable tester. It can test for opens, shorts, cross-connections and more. It detects cable types and measures lengths up to 2500m. The tester is composed of a main unit, receiver, and remote identifier to trace cables without interference.

Uploaded by

guecorandy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

MODEL:NF-300

Your excellent helper in cable test!

INSTRUCTION MANUAL
Wire Fault Locator

Your excellent helper in cable test!

ORIGINAL
AUTHENTIC

Patented products,
SHENZHEN NOYAFA ELECTRONIC CO.,LTD Counte
rfeiting not allowed

REV1.0
CONTENTS
Please read and learn safety instructions
before use or maintain the equipment
Overview......................................... .... .....01
Main functions .................................. .... ...02
●Keep the testers in right place to avoid hurt with the sharp probe. Technical Parameters...................... .... .....02
●Never put the equipment in the place with much dust, humidity Product interface and key introduction. ... .04
and high temperature (over 40℃).
Product operation method......... .... ...........05
●Please use battery according to the specification; otherwise, it
may result in damage to equipment.
a.Cable line-to-line test ......................... .... .....05
●Please never dismount the equipment arbitrarily. The mainten b.Cable length test ...................... .... ..............09
-ance and care shall be conducted by professional personnel. c.Cable tracing test ..................... ............ ......12
● The tester will shut off automatically if it does not work for
d.Crosstalk test ............................... .... .........15
15 minutes in succession.
●Please take out the battery in launcher and receiver if the Language Calibrate .................................16
equipment is not used for a long time so as to prevent that the Data loading.............................................16
battery liquid is leaked in future.
Language:Chinese or English...................16
●Never use the equipment to detect power cord with electricity
(such as power supply circuit of 220V), other wise, it may
Setup .......................................................17
result in damage to equipment and personal injury. Unit .........................................................17
●Never conduct related operation of communication line in Light ........................................................18
thunderstorm weather so as to prevent lightning stroke and
Auto off ...................................................18
impact on personal safety.
Auto-off time ...........................................18
Packing list..............................................19
Diagram of series products ......................20

Your excellent helper in cable test! Your excellent helper in cable test!
Overview Main functions
NF-300 is newly developed by our company which are capable ● Capable to test open, short , cross connection, reverse, pairing
of avoiding current inteference . The equipment is composed connection and broken wire positioning ( RJ11,RJ45, BNC C able ).
of three parts: main tester (NF-300), receiver (NF-300-S) and ● To perform crosstalk test on network cable to solve the potential
remote identifier (NF-300-R).It has couples of circuit state testing problem of slow speed.
functions including length test, cable line finding, line-to-line,
● To quickly find the target wire or cable among kinds of wires.
crosstalk and breaking point, serving as a practical tool for low
● Measure length of network cable, coaxial cable up to 2500m, no
voltage system installation and maintenance technicians
need of remote unit when measuring length.
of communication circuits and comprehensive wiring circuits. It is
● To make a accurate determination of short circuit position .
widely used in the fields like telephone system, computer networks
● To trace cable on exchanger or Router without current
and other metal lead circuits.
inteference.
● Low voltage prompt function is available (<6 V ).
● Functions of storage and memory.
POWER
● Automatic delay power on-off and backlight function.
● Lanuage& light brightness can be set in the system.
NF-300-S ● Single chip software watchdog design runs reliably.
NF-300
NOYAFA Anti-EI Wire Tracer

VOL
Technical parameters
Lang RJ45 RJ11
(1). Overall dimensions
Main tester: 175X80X43mm; Receiver: 218X46X29mm
PUSH TO TEST

Anti-EI Wire Remote identifier: 107X30X24mm.


Tracer Wire Fault Locator
RECEIVER
(2). Display
Dot matrix 128X64 (Effective visible area 56X40mm).
NF-300-R
(3). Power supply
WIREMAP

Main tester: 9V battery.


Wire Fault Locator
EMITTER Receiver: 9V battery.
(4).Testing cable types
STP/UTP 5E, 6E network cable, telephone cable, coaxial cable,
and common metal wires connected with alligator clip.

Main tester Receiver Remote identifier


(NF-300) (NF-300-S) (NF-300-R)

01 Your excellent helper in cable test! Your excellent helper in cable test! 02
(5).Detecting cable types Product interface and key introduction
STP/UTP 5E, 6E network cable, telephone cable, coaxial cable,
USB cable and common metal wires connected with alligator clip. SCAN POWER

(6).Operating environment temperature/humidity MAIN

RJ11 RJ45 BNC


-10℃ ~ +60℃ /20% ~ 70%;
(7).Testing device interface
POWER
Main unit: RJ45 (M), RJ45 (S)loop interface, RJ11main interface,
RJ11 loop interface, BNC connector,USB A-type female interface; NF-300 NF-300-S

NOYAFA

Remote identifier: RJ45, BNC connector。 Anti-EI Wire Tracer

VOL
Lang RJ45 RJ11
(8).Length measurement
Range: 1-2500m;
RJ11 USB-A Anti-EI Wire PUSH TO TEST
Tracer
Calibration precision: 2% (+/-0.5m, or +/-1.5 feet); (calibration; Wire Fault Locator
RECEIVER

cable >10m) measurement precision: 3% ((+/-0.5m, or +/-1.5 feet);


(AMP, CAT5E, 6E cable material)
Display unit: meter, inch, yard. Wire Fault Locator
EMITTER

(9).Length calibration, storage and data load


User can set a length value at a known length, store the value in
the system,which can be used for future choice. and the calibration
Main tester (NF-300) Receiver (NF-300-S)
length should be over 10m.
Main unit port instructions
(10). Line sequence and cable failure positioning
(1). Two RJ 45 interfaces on the main unit:
Open, short, reverse , cross, crosstalk, etc.
one of them is “MAIN” interface (“M” for short),
(11). Language set and the other is “SCAN” interface (“S” for short);
Users can choose English or Chinese for operation. Two RJ11 interface, USB-A interface
and BNC interface
(12). Setup (2). M interface is used for measuring length and
Unit & brightness & Auto-power off time can be set in this menu. others, but not for cable tracing; “S” interface is NF-300-R

used for cable tracing test and “local” connection test;

WIREMAP
(3). “Main RJ11" interface, USB interface and BNC
interface on the main unit are used for line-to-line,
length testing and line tracing; The
other RJ11 interface can be used
for checking wiremapping.
Remote identifier (NF-300-R)

03 Your excellent helper in cable test! Your excellent helper in cable test! 04
Product operation method Test result 1: Short circuit
Bootscreen If there is short circuit with the cable and terminal, it will show as below:
Synchronous self test ( - - - - -- self test dynamically displayed in the line (Short circuit with 3 and 6)
from left to right)
welcome
Short mapping:
to choose noyafa
NF-300 1 2 3 4 5 6 7 8

5 seconds later, the following main interface is displayed:


At this time, press any key to return to the main menu, and then press
NOYAFA NOYAFA
“ENTER” key for re-test.
Please do not perform test again until short circuit problem solved.
Lang RJ45 RJ11 USB BNC Setup
Test result 2: if the far end of the cable to be tested is not plugged in
There are six functional options in the main menu interface remote adapter (R) or cable is not plugged into the local port (S),
(1) Language— English or Chinese. the following interface is shown:
(2).RJ45 --- wiremapping / length measurement /
cable tracing / crosstalk testing
Cable open or
(3).RJ11— wiremapping / cable tracing
too Short !
(4).USB— Cable tracing
(5).BNC— wiremapping / length measurement / cable tracing
(6).Setting up— unit / light / auto-power-off time
Test result 3:correct connection
the following interface is shown:
Note:
Calibration— Seven calibration coefficient can be stored in it. Wire Map: Remote
User can calibrate network/ Coax cables. M: 1 2 3 4 5 6 7 8 G

Data loading---Select the calibration coefficients stored in system.


R: 1 2 3 4 5 6 7 8 G
a.Cable line-to-line test:
“M”stands for Master unit. “R” stands for remote unit “G” stands
Taking network test as an example: after entering RJ45 function to check
for “Grounded”.
wire mapping.At this time, the following interface is shown indicating test
is in process:
NOYAFA

Wire Mapping - - - - identify - - - -


Scan Cable
Cable Length

05 Your excellent helper in cable test! Your excellent helper in cable test! 06
Test result 4: In case of open circuit existing on far end of the cable, Test result 7: In case of open circuit existing in the cable when
the following interface is shown: testing with main tester and remote unit together, the following
interface is shown:
Wire Map: Remote Wire Map: Local
M: 1 2 3 X X 6 7 8
M: 1 2 3 4 5 6 7 8 G

R: 1 2 3 X X 6 7 8 G
S: 1 2 3 X X 6 7 8

In the figure, “X” shown in “4” & “5” pin in “M” & “R” line, It has two possible results.
In the figure, “X” shown in “4” and “5” pin position in “R” line, indicates there is
Both “4” and “5” pin are open curcuited. Or , either “4” or “5” pin is open.
open circuit in “4” and “5” pin of the remote pin.
Note: When checking wiremap with main tester and remote unit together,
Note: Because network cable is made of pair cores, if there is open circuit, the cable is tested in pair. Thus, if there is one pin is open , it will show in pair
it will show faults in pairs, just as above "4" &" 5". it means either "4" pin as above.
or "5" pin exsits an open circuit, or both "4" and "5" exsit an open circuit. To test which pin is open, users can check wiremap only with main tester like
Example 4,Example 5 and Example 6 do.
Test result 5: In case of open circuit existing at the near end of
the cable when testing only with main tester, the following interface Test result 8: 6-core telephone cable line sequence test
is shown: Before checking wiremap of telephone cable, users need to choose "RJ11"
and then check its wiremap. If the testing cable is in good connection, it will
Wire Map: Local
displays as follows:
M: 1 2 X 4 5 X 7 8
Wire Map: Local
M: 1 2 3 4 5 6
S: 1 2 3 4 5 6 7 8

S: 1 2 3 4 5 6
In the figure, “X” shown in “3” and “6” pin position in “M” line, indicates there is
open circuit in “3” and “6” pin of the near pin. At this time, press any key to return to the main menu, and then press
“ENTER” key for re-test.
Test result 6: In case of open circuit existing at the middle part Note: when checking wiremap of telephone cable, users can only test with
of the cable when testing only with main tester, the following main testers, for the remote unit has no RJ11 port.
interface is shown:
Test result 9: BNC coaxial cable line sequence test
Wire Map: Local
1 2 X 4 5 6 7 8 Before checking wiremap of BNC cable, users need to choose "BNC"; and
M:
then check its wiremap. If the testing cable is in good connection, it will
S: displays as follows:
1 2 X 4 5 6 7 8
Wire Map: Remote
M: 1 2
In the figure, “X” shown in “3” pin position in “M” and “S” line, indicates there is
open circuit in “3” pin of the middle part of the cable. Perform"Cable Length"
to locate the exact fault point. Refer to the related chapter below. R: 1 2

At this time, press any key to return to the main menu, and then press
“ENTER” key for re-test.

07 Your excellent helper in cable test! Your excellent helper in cable test! 08
Special use: In case of exchanger power-on, the main unit Test result 1: Short circuit
can test line sequence of the connecting cables If there is short circuit with the cable and terminal, the following interface is
Take network cable as an example: one end of the cable is connected with shown (Short circuit with 3 and 6)
“MAIN” interface of the main unit, and other end is connected with exchanger
interface. And direct connection test can be performed. If the exchanger
Short mapping:
interface tested is reliably connected, the following interfaces shown (exchanger
interface is 8-core): 1 2 3 4 5 6 7 8

Short mapping:
1 2 3 4 5 6 7 8 At this time, press any key to return to the main menu, and then press
“ENTER” key to other functions.
Please do not perform test again until short circuit problem solved.

Test result 2: In case of normal pairing and length test,


In case of open circuit with line 1 and 2 of the exchanger tested, the following the following interface is shown:
interface is shown (exchanger interface is 8-core):
1 Open 105.0m
2 Open 105.0m
Short mapping: 3 Open 105.0m
1 2 3 4 5 6 7 8 4 Open 105.0m

And then press “UP” or “DOWN” key, the following interface will further
be shown:
5 Open 105.0m
b.Cable length test:(Test length only with the main 6 Open 105.0m
tester,don’t connect cable into remote unit.) 7 Open 105.0m
9 Open 105.0m
Firstly insert one end of the testing cable into “M” port in the main tester. When
entering ”Cable Length” testing function to check the length.At this time, the
following interface is shown: Thus , the cable is almost 105m . Only one end of cable connect with main
tester, the other end needs no connection, so it show "Open" in the picture
NOYAFA At this time,press “ENTER” to return to the main menu,and then press
Wire Mapping - - - - identify - - - - “ENTER” key for re-test..
Scan Cable
Cable Length

Note: Due to different technical parameters with different branded cables,


users are recommended to use dynamic calibration function of the equipment
before measuring length (Refer to the related chapter for more details.).

09 Your excellent helper in cable test! Your excellent helper in cable test! 10
c. Cable tracing test:
Test result 5: BNC cable length test
After powering on the main tester and entering main test menu, press “UP”,
If to insert one end of the BNC cable to be tested into “BNC” port of the main “DOWN” key to move “ ” cursor to cable scan, and then press“ENTER”
key to find the line. The following interface will be shown:
tester, the other end is an open circuit, and then select length test, and then
press “ENTER” key to perform length test with the equipment, the following
interface will be shown:

1 Open 1 0.1m
Scanning ...
2 Open 1 0.1m

It indicates that length of BNC cable is 10.1m. At this time, press any key to Connect the cable to be found with the corresponding RJ45(Scan) port of the
return to the main menu, and then press “ENTER” key for re-test. emitter, (RJ11,USB or BNC). Take network line finding as an example:
connect the network cable to be found with RJ45 port, move “ ” cursor to
cable scan, and press “ENTER” key to perform line finding test as shown in
the figure below:

11 Your excellent helper in cable test! Your excellent helper in cable test! 12
The usage of receiver 2.Tracing Coax cable
Install 9V battery, push the test key, get close to the cables with probe.you can
hear “beep”, the power led flashes. When the probe finds the targeted cable,the
voice will be loudest, and the led light will be brightest.

Insert the cable into port BNC, Press the testing key of receiver, “Power” will be
lighted, then hold the receiver close to the cables, when the probe gets close to the
targeted one, you can hear clear and loud “beep,beep, beep” .
(Note: turning down the voice slowly help trace cable easiler. )

3.Locate the short or breakge point (eg: metal line)


Connect the metal line with the cable clips, press the testing key of receiver, hold
the receiver close to the cables, “beep, beep,beep” will generate, but when the
1.Tracing cable (RJ45/RJ11 Cable) which is connected to probe targets the breakge point, “beep,beep,beep” stops, which indicates that
switch or router. is where the breakage is.
Note: 1) the metal line is de-energized.
2) Turn up the voice, which helps locate breakge easily.
3) Two cables must be connected together, if only one cable, the black clip
has to be grounded.

Insert the cable into port RJ11/ RJ45 (S), Press the testing key of receiver, “Power”
will be lighted, then hold the receiver close to the cables, when the probe gets close
to the targeted one, you can hear clear and loud “beep,beep, beep” .
(Note: telephone cable into RJ11, Lan cable into port RJ45(S) )

13 Your excellent helper in cable test! Your excellent helper in cable test! 14
d. Crosstalk test Length Calibrate
The calibrated cable must be more than 10m, When starting dynamic calibration,
As shown the figure below: it shows 3, 6 and 4, 5 with crosstalk. The line
insert the same type of cables at a specified length into “M” port. It is unnecessary
pair with crosstalk will flash to indicate failure. In the line pair with crosstalk, to insert into remote unit.
end-to-end connection is correct. However the connected lines are from
different line pairs. Line pair crosstalk will cause an over large crosstalk,
Calibration ?
otherwise network speed will be slow.
No Yes
3 3
Select “Yes”, and then press “ENTER” key, the measured length will be shown:
6 6 At this time, press “UP” or “DOWN” key to adjust to show the actual length
as below:

- - Base Adjust- - -
4 4
12.5m
5 5
Connection diagram of crosstalk line pair
When length is given, press “ENTER” key to save the calibration value. The
screen will show calibration 1, cabliration 2...calibration 7. Users can choose
Crosstalk interface is shown as below: it from “Data load”, which can avoid more calibration next time.

Data loading:
Choose the functions of “Load data”, it will show 7 sets of length values which
Wire Map: Remote were stored before. Select the desired one and then start to test the cable length.

M: 1 2 3 4 5 6 7 8 Calibrate
Calibrate
1
2
Calibrate 5
Calibrate 6
Calibrate 3 Calibrate 7
Calibrate 4 Return

R: 1 2 3 4 5 6 7 8
Language: Chinese or English
The screen is as below.
Crosstalk line pair flashes
NOYAFA
Note: In case of the non-twisted-pair cable like telephone cable, 简 体 中 文
due to over large crosstalk, it generally shown as crosstalk. English
Return

15 Your excellent helper in cable test! Your excellent helper in cable test! 16
Choose English, then the screen will be as below. Light
move “ ” to “Ligh”, choose the brightness degree you need
NOYAFA NOYAFA as below shows.

NOYAFA

Lang RJ45 RJ11 USB BNC Setup Unit:Meter


Light:High
Auto off:ON

Setup Auto off


Choose “Setup” on the main menu,you will get the below screen ,
move“ ” to “ Auto off” , start power-off function to ON,
the screen would be like below.
NOYAFA NOYAFA

Unit:Meter NOYAFA
Light:High Unit:Meter
USB BNC Setup Auto off:ON Light:High
Auto off:ON

Unit : Auto-off time


move “ ” to “Auto-off time”, it will show as below.
Set unit: meter
When moving cursor “ ” to “Unit” item, choose “meter”,The following
NOYAFA NOYAFA
interface will be shown:
Light:High 15 min
NOYAFA
Auto off:ON 30 min
A u t o o f f- t i m e 60 min
Unit:Meter
Light:High
Auto off:ON Choose the time as you need, 15 mins, 30mins, 60mins,120mins.

Note: Setup of the unit of inch and yard is just the same as that of meter.

17 Your excellent helper in cable test! Your excellent helper in cable test! 18
Packing list

1. Emitter 1PCS 6. RJ45 Adaptor cable 1PCS

2. Receiver 1PCS 7. Alligator clip adaptor 1PCS

3. Remote adapter 1PCS 8. User manual 1PCS

4. Earphone 1PCS 9. Kit 1PCS

5. RJ11 Adaptor cable 1PCS 10. Color box 1PCS NF-868 NF-838 NF-8208

POWER

SCAN

NF-268
Anti-EI Wire Tracer
STATUS OFF

Anti-EI Wire Tracer


SCAN

OFF

TEST

VERIFY

NF-268 NF-806R NF-816

NF-468L NF-3468 NF8108-M

NF-388 NF-903 NF-906A