Abstract
This deployment guide provides detailed instructions for
installing, configuring, and operating a software-defined data
center (SDDC) based on the VMware Validated Design for
SDDC, using the VMware Cloud Builder virtual appliance to
automate the implement.
June 2019
Prepared by
H17783
The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with
respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness
for a particular purpose.
Use, copying, and distribution of any software described in this publication requires an applicable software license.
Copyright © 2019 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are
trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. [6/17/2019]
[Deployment Guide] [Document ID]
2
Table of contents
1 About VMware Validated Design Deployment ....................................................................................... 5
2 Hardware Requirements ........................................................................................................................ 6
3 Known Issues Within This Release ........................................................................................................ 8
4 Deployment Overview .......................................................................................................................... 10
5 Prepare the Environment for Automated Deployment ......................................................................... 14
6 Deploy VxRail Clusters for Management and Shared Edge/Compute Domain ................................... 21
7 Convert the VxRail Management Cluster Internal vCenter and Platform Services Systems to
Customer-Managed Systems ..................................................................................................................... 29
8 Configure SSH On All Hosts ................................................................................................................ 33
9 Prerequisites for Cloud Management Layer ......................................................................................... 34
10 Prerequisites for Business Continuity Layer ........................................................................................ 37
11 Deploy the SDDC Components ........................................................................................................... 39
12 Generate the JSON Deployment Files for the Management and the Shared Edge and Compute
Clusters ....................................................................................................................................................... 40
13 Validate the Deployment Parameters and Target Environment Prerequisites .................................... 41
14 Post-Deployment Operations Management Configuration .................................................................. 44
15 Post-Deployment Cloud Management Platform Configuration ............................................................ 46
16 Configure Single Machine Blueprints ................................................................................................... 54
17 Configure Unified Single Machine Blueprints for Cross-Region Deployment ...................................... 60
3
4
1 About VMware Validated Design Deployment
The VMware Validated Design Deployment for Region B on VxRail documentation provides step-by-step
instructions for installing, configuring, and operating a software-defined data center (SDDC) on the Dell
EMC VxRail Hyperconverged Infrastructure platform. This document is based on the VMware Validated
Design for SDDC, using VxRail infrastructure and the VMware Validated Design Cloud Builder to automate
the implementation of Region B.
This document is focused on deployment. Since the post-deployment tasks for tenant customization depend
on customer requirements, this document provides general guidance, but it does not contain step-by-step
instructions for performing all required post-configuration tasks.
Intended Audience
The VMware Validated Design Deployment of Region B documentation is intended for cloud architects,
infrastructure administrators, and cloud administrators who are familiar with and want to use VMware
software to quickly deploy and manage an SDDC that meets the requirements for capacity, scalability,
backup and restore, and extensibility for disaster recovery support.
5
2 Hardware Requirements
To implement the SDDC from this VMware Validated Design, your hardware must meet the requirements
listed in this section.
*Note: VMware 5.0 guidance states that the minimum memory requirement for Management nodes is
256 GB which is intended to support new features in future releases.
VxRail Dell Nodes have six memory slots which should be configured symmetrically to maximize
performance. The minimum requirement of 192 GB is supported; however, 384 GB will be
recommended in future releases.
6
Component Requirement per Region
For information about supported servers, CPU, storage, IO devices, and so on, see the Dell EMC VxRail
hardware information in the VMware Compatibility Guide.
Note If you scale out the environment with compute-only clusters, each server must meet the same
requirements as a server in the shared edge and compute cluster. You can use as many compute
servers as required.
7
3 Known Issues Within This Release
This VVD Region B deployment on VxRail document is certified and updated with each release of the
product or when necessary.
Cloud Builder fails to deploy Site Recovery Manager
The SRM automated deployment fails to install the site recovery manager software on the Windows VM.
The Cloud Builder UI reports that the SRM deployment has failed.
Assignment of VM priority within SRM Recovery Plan fails intermittently. This is reflected in the UI by the
task name and also within the vcf-bringup-debug.log file with a message similar to the following:
ERROR [0000000000000000,0000]
[c.v.e.s.o.model.error.ErrorFactory,threadPoolExecutor-4] [E9J7R5]
CONFIGURE_VM_PRIORITIES_FAILED Configuration for VM priorities for SRM
172.16.64.22 failed
Workaround:
1. Log in to the SRM Management UI with an administrative account.
2. Select the Recovery Plan tab and open the SDDC Cloud Management RP (Recovery Plan).
3. Confirm that the VM startup priority for each VM matches the following table.
VM Name Priority
vra01svr01a 2
vra01svr01b 2
vra01svr01c 2
vra01iws01a 3
vra01iws01b 3
vra01ims01a 4
vra01ims01b 4
vra01dem01a 5
vra01dem01b 5
4. Select the Recovery Plan tab and open the SDDC Operations Management RP.
5. Confirm that the startup priority for each VM matches the following table.
VM Name Priority
vrops01svr01a 1
vrops01svr01a 2
8
vrops01svr01a 3
vrs01lcm01 4
6. Open the Active Cloud Build deployment and select Retry to restart the task.
7. Confirm that Cloud Builder completes the task successfully.
9
4 Deployment Overview
This section provides a brief overview of the deployment process. It is intended as a preparation tool to
orient you with the process, and as a reference to quickly identifying where you are in the process flow as
you proceed through the deployment.
The process has three distinct sections.
▪ Section 1 focuses on deploying the infrastructure services and preparing for the cloud builder
deployment.
▪ Section 2 covers the cloud builder tasks and deployment.
▪ Section 3 describes the post deployment tasks which are conducted within the vRealize Suite.
10
Requirements
VLAN – Mgt, vSAN, vMotion
IP addresses- -ESXi Hosts,
VxRail Manager, PSC, vCenter
NTP Server
DNS configuration
Configure DNS
Host entries
Load Balance PSC
Deploys
Deploy RegionB VxRail Manger
Solve Procedure VxRail Management
Embedded VC Cluster
PSC(i)
(Solve Procedure) vCenter(i)
ESXi hosts(4)
Upload VVD
Software Bundle
Upload
Certificates
Deploy External
Manual vCenter Server
Automated
Mount vCenter
Mount vCenter ISO on
ISO
Windows System
Create external
Perform Installer
VC JSON File
deployment
vcsa-cli
deployment
Compute Edge
vCenter
Upload Cloud
Builder Param File
Generate VxRail
JSON Files
Download a copy
of VxRail JSON file
VxRail Deployment
Complete
11
Preparation for Cloud Builder
Similar to the Region A document, the following dependencies must be established before proceeding to
the Cloud builder validation and deployment.
▪ Cloud Builder requires SSH access to all ESXi Hosts, therefore we must enable SSH on all hosts. A
Windows 2016 virtual machine template is required for the IaaS components of the deployment. Details
on the configuration of the template are listed within this document.
▪ If the deployment includes data protection with SRM, a Windows VM must be deployed and configured
to support the SRM services.
▪ The Cloud Builder parameter file must be completed and validated. Since the deployment is dependent
on properties defined within the file, the properties should also be validated.
Cloud Builder
Dependencies
Management Domain
Validation
Compute Domain
Validation
Management Domain
Deployment
Compute Domain
Deployment
Cloud Builder
Deployment
Completed
Finalize the deployment by setting the monitoring policies, and configuring the vRealize tenant and Service
Catalog to verify the environment is functional.
The tasks in this section are related to creation of VM templates, vRA blueprints, and catalog services.
Custom services are out-of-scope for this deployment and would be completed after phase three.
12
Start
Post-Deployment
CMP Configuration
End of
Infrastructure
13
5 Prepare the Environment for Automated
Deployment
Prepare the environment for Automated Deployment Before you start the automated SDDC
deployment, verify that your environment fulfills the requirements listed in the following section. Prepare
each layer of the SDDC by deploying and configuring the necessary infrastructure, operational, and
management components.
Prerequisite Value
Environment ▪ Verify that your environment is configured for deployment of the SDDC. See
Prepare the Environment for Deployment in Region B.
Physical Network ▪ Verify that your environment meets all physical network requirements, all host
names and IP addresses are allocated for external services and SDDC
components.
Active Directory ▪ Verify that Active Directory is configured with all child domains, all service
accounts and groups are created and configured.
DNS ▪ Verify that DNS is configured with VxRail and SDDC entries within the root and
child domains.
NTP Services ▪ Verify that two external NTP servers are configured and time synchronization is
configured on all ESXi hosts and AD domain controllers.
Software Features ▪ Fill in the Deployment Parameters XLS file for Region B. See Deployment
Specification in the VMware Validated Design Planning and Preparation
documentation.
▪ Verify that you have generated CA-signed certificates for the management
components of the SDDC. See Generate Signed Certificates for the SDDC
Components in Region B.
Installation Packages ▪ Download the .iso file for the software bundle for VMware Validated Design to
your local file system.
For additional information, see the VMware Validated Design Planning and Preparation documentation.
14
There are two documents which are used to capture details for the deployment:
▪ Dell EMC Pre-Engagement Questionnaire - provides a documentation tool to collect details for the
VxRail deployment.
▪ VMware Cloud Builder Deployment Parameters spread sheet - captures the configuration details for the
SDDC deployment.
Procedure
1. Obtain the relevant documents from Solve and the VMware Web Site or Cloud Builder.
2. Thoroughly complete the documents and verify the details of the user accounts, DNS entries, and
network configuration contained within the file.
3. Get help with the review.
These documents should be completed prior to delivery. The ISBU and Dell EMC are available to
review the documents prior to the engagement.
Perform the DNS configuration for the platform services load balancer
Configure the DNS load balancer record to emulate the NSX-V load balancer.
Prerequisites
Verify that the following static IP addresses are allocated.
▪ Static IP address for the Management Platform Services controller
▪ Static IP address for the Platform Services controller load balancer virtual IP
15
Table 4. IP addresses and host names for the Platform Services controller load balancer and
the Platform Services controller for the Management Cluster
Procedure
1. Log in to the dc01rpl.rainpole.local DNS Server.
2. Open the Windows Start menu and enter dnsmgmt.msc in the Search bar. Press Enter.
The DNS Manager dialogue box appears.
3. Create an A Record for the Platform Services Controller Load Balancer Name VIP.
Setting Value
Name lax01psc01
IP address 172.17.11.61
Setting Value
16
Generate certificates for the SDDC components
To ensure secure and operational connectivity between the SDDC components, generate new signed
certificates for the SDDC components in Region B.
Use the Certificate Generation Utility for VMware Validated Design (CertGenVVD) to generate the certificate
configuration files based on the deployment specification configured in the Deployment Parameters XLS file
for Region A. You then generate new certificates signed by the Microsoft certificate authority (MSCA) for all
management products.
You later upload the newly generated and signed certificates to VMware Cloud Builder as part of the
deployment and configuration procedure of the virtual appliance.
For information about the VMware Validated Design Certificate Generation Utility, see VMware Knowledge
Base article 2146215 and VMware Validated Design Planning and Preparation.
Prerequisite Value
Active Directory ▪ Verify that the Certificate Authority Service and the Certificate Authority Web
Enrolment roles are installed and configured on the Active Directory Server.
▪ Verify that a new Microsoft Certificate Authority template is created and enabled.
▪ Use a hashing algorithm of SHA-256 or higher on the certificate authority.
▪ Verify that relevant firewall ports relating to the Microsoft Certificate Authority and
related services are open.
Windows Host ▪ Ensure the Windows host system where you connect to the data center and
generate the certificates is joined to the domain of the Microsoft Certificate
Authority.
▪ Install Java Runtime Environment version 1.8 or later.
▪ Configure the JAVA_HOME environment variable to the Java installation
directory.
▪ Update the PATH system variable to include the bin folder of Java installation
directory.
▪ Install OpenSSL toolkit version 1.0.2 for Windows.
▪ Update the PATH system variable to include the bin folder of the OpenSSL
installation directory.
Software Features ▪ Fill in the Deployment Parameters XLS file for Region B. See Deployment
Specification in the VMware Validated Design Planning and Preparation
documentation.
17
Create and add a Microsoft Certificate Authority template
(Optional) Set up a Microsoft Certificate Authority template on the Active Directory (AD) servers for the
region. The template contains the certificate authority (CA) attributes for signing certificates for the SDDC
components. After you create the template, add it to the certificate templates of the Microsoft CA.
Create and configure the VMware certificate authority template to generate and sign the certificates for the
management components in Region A. If the VMware certificate authority template exists and is added to
the certificate templates of the Microsoft CA, you can skip this procedure.
Procedure
1. Log in to the Active Directory server using a Remote Desktop Protocol (RDP) client using the following
credentials:
Setting Value
Password ad_admin_password
18
Generatе signed certificates for the SDDC Components
Use the Certificate Generation Utility for VMware Validated Design (CertGenVVD) to generate new signed
certificates for the SDDC components.
Procedure
1. Log in to the Windows host that has access to your data center.
2. Set the execution policy to Unrestricted.
a Click Start, right click Windows PowerShell, and select More > Run as Administrator.
b Set the execution policy by running the following command:
Set-ExecutionPolicy Unrestricted
a Open the populated Deployment Parameters XLS file and select the CertConfig worksheet.
b From the File menu, select Save As…, set the file format to Comma delimited (*.csv), rename the
file to S DD C - C e rt C onf i g.c sv , and click Save.
c Rename the C:\CertGenVVD-version\ConfigFiles folder to ConfigFiles.Old.
d Create a new C:\CertGenVVD-version\ConfigFiles folder.
e In the Windows PowerShell terminal, navigate to the C:\CertGenVVD-version folder and run the
following command.
.\Certconfig-version.ps1 SDDC-Certconfig.csv
Setting Value
Default OU Rainpole
Default State CA
Default Country US
19
▪ lax01w01nsx01.txt
▪ lax01w01vc01.txt
4. In the Windows PowerShell terminal, navigate to the C:\CertGenVVD-version folder and validate
the configuration by running the following command.
.\CertGenVVD-version.ps1 -validate
b Follow the on-screen instruction and enter a passphrase for PEM/P12 file encryption.
All MSCA signed certificates are generated in the C:\CertGenVVD-version\SignedByMSCACerts
folder.
6. Rename the C:\CertGenVVD-version\SignedByMSCACerts folder to SignedByMSCACerts-
lax-jd.
20
6 Deploy VxRail Clusters for Management and
Shared Edge/Compute Domain
To prepare for the SDDC environment, two VxRail Clusters are deployed:
▪ A management cluster that hosts the SDDC cloud management services, vCenter Services, NSX
Managers, and the cloud builder virtual appliance
▪ A shared edge and compute cluster that hosts the NSX controllers and Edge Services for the Workload
domain.
The first cluster, for the management Domain, provides the foundation for the SDDC environment. It is
deployed using the VxRail embedded deployment procedure, resulting in the cluster hosting the platform
services controller and vCenter instance which manage its resources. Those services are converted from
VxRail Managed to customer managed after the VxRail cluster initialization is complete using a VxRail
Manager conversion utility. Once converted, the vCenter and PSC are no longer managed or included in
the VxRail Manager Lifecycle Management processes.
A second instance of vCenter and PSC are deployed within the Management vCenter for the Shared Edge
and Compute cluster management. The Platform Services controllers are federated and abstracted through
an NSX load balancer.
Network services, DNS, and NTP must be configured prior to performing this task
21
FQDN IP VLAN Default NTP Server
ID Gateway
5. Download the current VxRail SolVe procedure from the Solve Desktop or Dell EMC Solve Online
(currently available at https://solveonline.emc.com/solve/products) for VxRail embedded vCenter
deployment.
22
Table 40. vSAN host configuration
Procedure
1. Log in to the Management vCenter in Region A.
Setting Value
2. In the navigator, select the Data Center and click Create / Register VM.
23
3. The New virtual machine wizard appears.
4. On the Select creation type dialog box, select Deploy a virtual machine from an OVF or OVA file and
click Next.
5. On the Select OVF and VMDK files dialog box, enter lax01cb01 for the virtual machine name, select
the VMware Cloud Builder.ova file, and click Next.
6. In the Select storage dialog box, select VxRail Manager vSAN Datastore-<uniqueID>, and click Next.
7. On the License agreements page, click I agree to accept the license agreement, and click Next.
8. On the Deployment options page, enter the following values and click Next.
Setting Value
9. In the Additional settings dialog box, expand Application, enter the following values, and click Next.
Option Value
IP address 172.17.11.60
VM hostname lax01cb01
DNS 172.17.11.5,172.17.11.4
NTP ntp.sfo01.rainpole.local,ntp.lax01.rainpole.local
10. On the Ready to complete dialog box, review the virtual machine configuration and click Finish.
24
Deploy the shared compute and edge platform service controller
VVD relies upon two platform services controllers for high availability and redundancy. In a dual-region
deployment, the PSCs are federated providing configuration details including services accounts and
vCenter service details across both regions.
The goal of this task is to deploy the necessary PSC services in Region B while also joining the PSCs to the
Region A SSO domain.
In order to establish that linkage, we deploy the PSC for the Region B Shared Edge and Compute into the
Region B Management vCenter. We then join that PSC to the shared edge and compute PSC in Region A
(sfo01w01psc01.sfo01.rainpole.local)
This process enables the use of a common SSO domain for all components of the SDDC supporting
vCenter enhance linked mode, as well as providing a common identity source to the Active Directory
service accounts.
The embedded PSC in the Region B Management Domain will be replaced and linked to Region A during
the automated workflows. It is in use supporting the Region B.
Procedure
1. Obtain a copy of the vvd-bundle-johndory-5.0.0-13453959 software bundle.
a. On a windows machine mount the ISO and extract the vCSA image from <drive>:\vvd-
bundle-johndory-5.0.0-13453959\vcenter_ova
b. Copy the ISO to the local drive.
2. Mount the ISO file on Windows VM and open the drive where the ISO is mounted.
a. Change directory to the location of the Windows installer, for example: E:\vcsa-ui-
installer\win32
3. Select the installation application to launch the deployment wizard.
4. Select the Installer option and click Next.
5. Accept the license agreement and continue.
6. Select the deploy a Platform Services Controller option from the External Platform Services
Controller section of the form and click Next.
7. Enter the Fully Qualified Domain Name of the Region B Management vCenter Server
lax01m01vc01.lax01.rainpole.local
8. Select the folder to install the VM.
9. Select the compute resource and click Next.
10. Enter the VM name lax01w01psc01.lax01.rainpole.local and the root password and click
Next.
11. Select the vSAN datastore for the desired storage location and click Next.
12. Select the port group that begins with vCenter, and specify the FQDN, IP address, and other system
properties and click Next.
13. Confirm that the values are correct and click Finish.
25
5. Confirm the join the VMWare CEIP check is selected and click Next.
6. Confirm the details and click Finish to deploy.
7. Log into the vCenter Server.
8. Select the Administration option → System Configuration interface
a. Ensure that the lax01w01psc01.lax01.rainpole.local is listed in the node view.
Procedure
1. Using the same Windows VM that was used to deploy the PSC, select the installer application to launch
the deployment wizard.
2. Select the Installation option and click Next.
3. Accept the license agreement and continue
4. Select the deploy a vCenter Server option from the External Platform Services Controller
section of the form and click Next.
5. Enter the Fully Qualified Domain Name of the Region B management vCenter Server
lax01m01vc01.lax01.rainpole.local
6. Select the VM placement values, folder, compute resource, and click Next.
7. Enter the VM name lax01w01psc01.lax01.rainpole.local and the root password and click
Next.
8. Select the vSAN datastore for the desired storage location and click Next.
9. Select the port group that begins with “vCenter, and specify the FQDN, IP address, and other system
properties and click Next.
10. Confirm that the values are correct and click Finish.
When the vCenter has been deployed, select Continue to join it to the lax01w01psc01 Platform
Services Controller in Region B.
11. Start the configuration process and select join and existing domain option by entering the target PSC
that you would like to join sfo01w01psc01.sfo01.rainpole.local.
12. Select the configuration option
a. Specify the lax01w01psc01.lax.rainpole.local platform services controller instance.
b. Provide the SSO administrative credentials.
c. Select Next to deploy the vCenter.
UID and GID values were obtained from the initial PSC.
26
Procedure
1. SSH into the lax01m01psc01.lax01.rainpole.local PSC as root.
a Run the following command to verify the existing user ID and group ID values:
grep vxadmin /etc/passwd
5. Log in to the DCUI of the Workload Domain vCenter Server to enable the global privilege for the
Account.
6. Select Administration > Workload vCenter Server from the drop-down menu.
7. Select Global Permissions and click the to add a new permission.
8. Select localos from the Domain drop down and locate the vxadmin@localos account. Click Add.
9. From the Assign Role, select VMware HCIA Management global privilege to the local account, select
Propagate to children, and click OK.
27
28
7 Convert the VxRail Management Cluster Internal
vCenter and Platform Services Systems to Customer-
Managed Systems
Before proceeding with the deployment, you must convert the PSC and vCenter to customer-managed
systems. That task is performed through a python utility on the VxRail Manager server. The purpose of
this task is to:
• Disassociate the services from VxRail Manager and prepares the vCenter to join the Region A
SSO.
• Enable the use of enhanced linked mode and cross-site vCenter NSX.
• Provide better alignment with VVD for the Lifecycle Management processes.
This process is dependent on the Dell EMC SolVe procedure Migrate VxRail Cluster from embedded VC to
External vCenter.
Access the SolVe Desktop tool or SolVe Online (solveonline.emc.com) to download the Migrate Embedded
VxRail vCenter to VVD vCenter and Platform Services Controller procedure.
Follow the instructions in that document to convert the embedded vCenter and PSC instance.
Procedure
1. Log into the management vcenter UI.
2. Create snapshots of the following VMs:
• lax01m01vc01.lax.rainpole.local
• lax01m01psc01.lax.rainpole.local
• lax01w01psc01.lax.rainpole.local
29
3. SSH or log into vCenter lax01m01vc01 as the root user.
4. Enter the following command to view the current configuration of the vCenter:
/usr/lib/vmware-vmafd/bin/vmafd-cli get-ls-location --server-name localhost
Procedure
1. Log into the vCenter Server.
2. Locate the lax01w01vc01 vCenter Server from the global inventory list.
3. Right-click on the vCenter and select New Data Center.
4. Enter the value for the data center defined within the PEQ and/or parameter file.
5. Click OK and proceed to the next task.
30
Procedure
1. Download the VxRail External vCenter Installation Guide from the Solve Desktop or Solve Online
through the Dell EMC Support web site.
The SolVe tool produces the deployment guide with the detailed instructions and dependencies for
deploying the VxRail external cluster.
2. Follow the procedures within the SolVe deployment documentation to complete the shared edge and
compute VxRail cluster deployment.
3. Deploy the VxRail using Cloud Builder Generated JSON input file (Optional)
a. VxRail deployment supports two options for defining the configuration properties. A manual
process where details are manually entered, and a JSON configuration file which is pre-
populated with configuration details.
b. Cloud Builder produces multiple JSON files from the parameter file, including a VxRail input file
for both clusters. If the parameter file is available, log into Cloud Builder and follow the process
to generate the JSON files.
c. Obtain the vxrail-regb-comp-manager.json file from Cloud Builder using ftp or SCP. The
file is available in the /opt/vmware/sddc-
support/cloud_admin_tools/Resources/vxrail-regb directory.
See Generate the JSON Deployment Files for the Management and the Shared Edge and Compute
Clusters in Region A for steps to upload and create the json file.
4. Reference the following information for either manual or Cloud Builder VxRail deployment.
Table 53. VxRail Manager, vCenter, and Platform Services controller details
lax01w01psc01.lax01.rainpole.local 172.17.11.63 “” “”
31
Table 54. Management cluster hosts
After completion of the VxRail Manager deployment, connect to VxRail Manager and confirm the health of
all components in the cluster.
32
8 Configure SSH On All Hosts
Complete the initial configuration of all ESXi hosts by enabling the SSH service to allow Cloud
Builder remote connectivity.
Repeat this procedure for all hosts in the management and shared edge and compute clusters.
See Prerequisites for Installation of ESXi Hosts in Region A.
Procedure
1. Log in to the vSphere host by using the VMware Host Client.
a Open a Web browser and go to ht tp s:/ / l ax 0 1m 0 1e sx 0 1. la x 01 . ra inp ol e. l oc al .
b Log in using the following credentials.
Setting Value
Password esxi_root_user_password
33
9 Prerequisites for Cloud Management Layer
To prepare the cloud management layer for automated deployment of the SDDC components using Cloud
Builder, you deploy and configure the Master Windows system for vRealize Automation Infrastructure as a
Service (IaaS) nodes and deploy and configure the external SQL server for vRealize Automation.
Setting Value
VM Name master-iaas-vm
vCPU 2
Memory 8 GB
Virtual Disk 60 GB
Datastore lax01m01-vSAN
Network Requirements:
▪ Verify that you have allocated a static or DHCP IP address for the master Windows system.
▪ Verify that the master Windows system has access to the Internet.
Table 8. Software requirements for the master Windows system
Component Requirement
34
Component Requirement
Secondary Logon Service Start the Secondary Logon service and set the start-up
type to Automatic.
Procedure
1. Deploy the master Windows system for vRealize automation with the specified configuration.
2. Log in to the vRealize automation master Windows virtual machine by using a Remote Desktop
Protocol (RDP) client.
a Open an RDP connection to the virtual machine.
b Log in using the following credentials.
Settings Value
Password windows_administrator_password
3. Click Start, right-click Windows PowerShell and select More > Run as Administrator.
3. Set the PowerShell execution policy by running the following command.
Set-ExecutionPolicy Unrestricted
set-ItemProperty -Path
"HKLM:\Software\Microsoft\Windows\CurrentVersion\Policies\System" -Name
"EnableLUA" -Value "0"
6. Verify that the source path for Microsoft Windows Server is available.
a Mount the Microsoft Windows server ISO file on the master Windows system virtual machine.
b Create the\sources\sxs directory by running the following command in Windows PowerShell.
mkdir C:\sources\sxs
c Copy the Microsoft Windows Server source files from the sources\sxs directory on the ISO file to
the C:\sources\sxs directory on the virtual machine.
35
d Update the registry with the full system path of the Microsoft Windows Server source files by
running the following command in Windows PowerShell.
New-Item -Path
"HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\Servicing"
set-ItemProperty -Path
"HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\Servicing\" -Name
"LocalSourcePath" -value "c:\sources\sxs"
8. Create the svc-vra user profile by logging in to the vRealize automation master Windows virtual
machine.
a Open an RDP connection to the virtual machine.
b Log in using the following credentials.
Settings Value
Password svc-vra_password
36
10 Prerequisites for Business Continuity Layer
To prepare the business continuity layer for automated deployment of the SDDC components using
VMware Cloud Builder, you deploy and configure the Site Recovery Manager Windows virtual machine.
Setting Value
VM Name lax01m01srm01
vCPU 2
Memory 2 GB
Virtual Disk 40 GB
Datastore lax01-m01-vSAN
Setting Value
FQDN lax01m01srm01.lax01.rainpole.local
37
Table 11. Software requirements for the Site Recovery Manager VM
Setting Value
Procedure
Deploy the Site Recovery Manager virtual machine with the specified configuration.
1. Log in to the Site Recovery Manager virtual machine by using a Remote Desktop Protocol (RDP) client.
a Open an RDP connection to the lax01m01srm01.lax01.rainpole.local virtual machine.
b Log in using the following credentials.
Settings Value
Password windows_administrator_password
2. Click Start, right-click Windows PowerShell, and select More > Run as Administrator.
3. Add the svc-srm service account to the local Administrators group by running the following command.
38
11 Deploy the SDDC Components
After you deploy and configure the VMware Cloud Builder appliance, generate the JSON deployment files
based on the values populated in the Deployment Parameters XLS file. You then validate the deployment
files against the necessary run parameters and start the automated deployment of the SDDC components
for the management cluster and for the shared edge and compute cluster in Region B.
Procedure
1. Log in to the VMware Cloud Builder virtual appliance.
a Open a connection to lax01cb01.lax01.rainpole.local using an SCP software like
WinSCP.
b Log in using the following credentials.
Setting Value
Password cloudbuilder_admin_password
Password cloudbuilder_admin_password
/opt/vmware/vvd/cloud-builder/install/reconfigure.sh
The script sets the full system path to each application's installation file, configures specific
application properties, and restarts the bring-up service.
39
12 Generate the JSON Deployment Files for the
Management and the Shared Edge and Compute
Clusters
After you have populated all required configuration values in the Deployment Parameters XLS file, upload it
to the VMware Cloud Builder appliance and generate the JSON files that automate the deployment of the
SDDC components in the management and the shared edge and compute clusters.
Procedure
1. Log in to VMware Cloud Builder.
a Open a Web browser and go to ht tp s:/ /l ax 0 1c b0 1 . la x 01 .r a inpo l e. loc a l .
b Log in using the following credentials.
Setting Value
Password cloudbuilder_admin_password
2. On the End User License Agreement page, click Accept License Agreement.
3. Generate the JSON file used for automated deployment of the SDDC components.
a In the Cloud Builder Navigator, select the Deployment Wizard icon.
b In the Upload Config File tab, from the Select Architecture Type drop-down menu, select the VVD
for SDDC Region B architecture and click the Upload Config File button.
c Navigate to the Deployment Parameters XLS file and click Open.
d Click the Generate JSON button.
Cloud Builder generates one JSON file for the management cluster and one JSON file for the
shared edge and compute cluster.
vvd-std-regb- Compute 2
comp.json
4. Monitor the process and check the following log files for errors.
Table 13. VMware Cloud Builder JSON Generator Log File Location
After the JSON files for Region B are generated, validate their content for configuration, application, and
bring-up readiness, and perform validation of the target platform.
40
13 Validate the Deployment Parameters and Target
Environment Prerequisites
Perform validation of both JSON deployment files and specific target environment prerequisites to ensure
that you can successfully deploy the components of the management and the shared edge and compute
clusters using VMware Cloud Builder.
Validate the JSON deployment files for both the management and the shared edge and compute clusters. If
any of the tests fail, you must remediate any errors and perform the validation process again. Additional
information can be found in the audit log file.
Table 14. VMware Cloud Builder Platform Audit Log File Location
Procedure
1. Log in to VMware Cloud Builder.
a Open a Web browser and go to https://lax01cb01.lax01.rainpole.local.
b Log in using the following credentials.
Setting Value
Password cloudbuilder_admin_password
2. In the Cloud Builder Navigator, click the Deployment Wizard icon.
3. Select the Validate Environment tab.
4. From the Select File to Validate drop-down menu, select the vvd-std-regb-mgmt.json file and click
Validate.
5. If validation fails because of issues with the signed certificate files, resolve the issues and reupload the
modified certificate files.
a Upload the modified certificate files to the Cloud Builder appliance using an SCP software like
WinSCP.
b Open an SSH connection to lax01cb01.lax01.rainpole.local.
c Run the following command.
su /opt/vmware/vvd/cloud-builder/install/reconfigure.sh
6. In the Upload Config File tab, from the Select Architecture Type drop-down menu, select the VVD for
SDDC Region B architecture and click the Upload Config File button.
7. Navigate to the updated Deployment Parameters XLS file and click Open.
8. On the Overwrite Existing JSON File(s) dialog box, select Yes.
41
9. Select the Validate Environment tab, from the Select File to Validate drop-down menu, select the vvd-
std-regb-mgmt.json file and click Validate.
The vvd-std-regb-mgmt.json file is successfully validated against the predefined run parameters.
10. Click the Back button, from the Select File to Validate drop-down menu, select the vvd-std-regb-
comp.json file and click Validate
The vvd-std-regb-comp.json file is successfully validated against the predefined run parameters.
11. After successful validation of vvd-std-regb-mgmt.json and vvd-std-regb-comp.json files, click
Next to start the deployment of the management cluster.
Password cloudbuilder_admin_password
Table 15. VMware Cloud Builder Bring Up Service Log File Location
/opt/vmware/bringup/logs/vcf-bringup-
debug.log
Start the automated deployment for the shared edge and compute
cluster
After you successfully validate the vvd-std-regb-comp.json file, start the automated deployment of the
components in the shared edge and compute cluster.
Procedure
1. Log in to VMware Cloud Builder.
a Open a Web browser and go to ht tp s:/ /l ax 0 1c b0 1 . la x 01 .r a inpo l e. loc a l .
b Log in using the following credentials.
42
Setting Value
Password cloudbuilder_admin_password
Table 16. VMware Cloud Builder Bring Up Service Log File Location
/opt/vmware/bringup/logs/vcf-bringup-
debug.log
43
14 Post-Deployment Operations Management
Configuration
After the operations management applications are deployed in Region B, perform post-deployment tasks for
the operations management layer. You reconfigure the automatic synchronization of authentication sources
in vRealize Operations Manager, and enable define monitoring goals for the default policy.
Procedure
1. Log in to vRealize Operations Manager by using the operations interface.
a Open a Web browser and go to https://vrops01svr01.rainpole.local.
b Log in using the following credentials.
Setting Value
Password deployment_admin_password
44
Procedure
1. Log in to vRealize Operations Manager by using the operations interface.
a Open a Web browser and go to http s:/ /v ro ps 0 1sv r0 1 .r a inpo le .l oc a l .
b Log in using the following credentials.
Setting Value
Password deployment_admin_password
45
15 Post-Deployment Cloud Management Platform
Configuration
After the Cloud Management Platform (CMP) is deployed in Region B, perform post-deployment
tasks for the cloud management layer. You finish the SDDC configuration in your environment and
confirm a successful provisioning of virtual machines using newly created blueprints.
Procedure
1. Log in to vCenter Server by using the vSphere Client.
a Open a Web browser and go to http s:/ /sf o0 1 m0 1 v c0 1. sfo 0 1. r ain pol e. l oc al /ui .
b Log in using the following credentials.
Setting Value
Password vsphere_admin_password
Password vsphere_admin_password
6. From the Home menu, select Content Libraries, and click the + icon.
The New Content Library wizard appears.
7. On the Name and location page, enter the following settings and click Next.
46
Setting Value
Name lax01-w01cl-vra01
8. On the Configure content library page, select Subscribed content library, enter the following
settings, and click Next.
Setting Value
Password sfo01-w01cl-vra01_password
9. On the Add storage page, click the Select a datastore radio button, select the sfo01-m01-vsan01
datastore to store the content library, and click Next.
10. On the Ready to complete page, click Finish.
In the Recent Tasks pane, a Transfer Files status indicates the time to finish the file transfer.
Procedure
1. Log in to the vRealize Automation Rainpole portal.
a Open a Web browser and go to ht tp s:/ /v r a0 1 sv r 0 1. r ain pol e. lo c al /v c ac / org / ra inpo l e .
b Log in using the following credentials.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
47
Setting Value
Name LAX-Production-Policy
4. Click the New icon, configure the following settings, and click OK.
Setting Value
Name LAX-Development-Policy
5. Click the New icon, configure the following settings, and click OK.
Setting Value
Name LAX-Edge-Policy
Group Name
Production LAX01-Comp01-Prod-Res01
Development LAX01-Comp01-Dev-Res01
Procedure
1. Log in to the vRealize Automation Rainpole portal.
a Open a Web browser and go to ht tp s:/ /v r a0 1 sv r 0 1. r ain pol e. lo c al /v c ac / org / ra inpo l e .
b Log in using the following credentials.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
2. Navigate to Infrastructure > Reservations > Reservations and select New > vSphere (vCenter).
48
3. On the New Reservation - vSphere (vCenter) page, click the General tab, and configure the following
values for each group.
4. On the New Reservation - vSphere (vCenter) page, click the Resources tab.
a Select lax01-w01-comp01 (lax01w01vc01.lax01.rainpole.local) from the Compute resource
drop-down menu.
b In the This Reservation column of the Memory (GB) table, enter 20 0.
c In the Storage (GB) table, select the check box for your primary datastore, for example, lax01-
w01-vsan01, enter 2 0 00 in the This Reservation Reserved text box. Enter 1 in the Priority text
box, and click OK.
d Select lax01-w01rp-user-vm from the Resource pool drop-down menu.
5. On the New Reservation - vSphere (vCenter) page, click the Network tab.
6. On the Network tab, select a network path listed in the following table, and select the corresponding
network profile from the Network Profile drop-down menu for the business group whose reservation
you are configuring.
vxw-dvs-xxxxx-Production-Web-VXLAN Ext-Net-Profile-Production-Web
vxw-dvs-xxxxx-Production-DB-VXLAN Ext-Net-Profile-Production-DB
vxw-dvs-xxxxx-Production-App-VXLAN Ext-Net-Profile-Production-App
vxw-dvs-xxxxx-Development-Web-VXLAN Ext-Net-Profile-Development-Web
vxw-dvs-xxxxx-Development-DB-VXLAN Ext-Net-Profile-Development-DB
vxw-dvs-xxxxx-Development-App-VXLAN Ext-Net-Profile-Development-App
7. Click OK.
8. Repeat this procedure and create a reservation for the Development Business Group.
49
Create reservations for the user edge resources
Before members of a business group can request virtual machines, fabric administrators must allocate
resources to that business group by creating a reservation. Each reservation is configured for a specific
business group to grant them access to request virtual machines on a specified compute resource.
Perform this procedure twice to create edge reservations for both the production and development
business groups.
Table 18. Business Group Names
Group Name
Production LAX01-Edge01-Prod-Res01
Development LAX01-Edge01-Dev-Res01
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
2. Navigate to Infrastructure > Reservations > Reservations, and click New vSphere (vCenter).
3. On the New Reservation - vSphere (vCenter) page, click the General tab, and configure the following
values for your business group.
4. On the New Reservation - vSphere (vCenter) page, click the Resources tab.
50
d Select lax01-w01rp-user-edge from the Resource pool drop-down menu.
5. On the New Reservation - vSphere (vCenter) page, click the Network tab.
6. From the Network Paths list, select the network path check boxes listed in the following table, and
from the Network Profile drop-down menu select the corresponding network profile for the business
group whose reservation you are configuring.
vxw-dvs-xxxxx-Production-Web-VXLAN Ext-Net-Profile-Production-Web
vxw-dvs-xxxxx-Production-DB-VXLAN Ext-Net-Profile-Production-DB
vxw-dvs-xxxxx-Production-App-VXLAN Ext-Net-Profile-Production-App
Procedure
1. Log in to the Compute vCenter Server by using the vSphere Client.
a Open a Web browser and go to http s:/ /l a x0 1w 01v c0 1 .l ax 0 1. r ain pol e .lo ca l/ ui .
b Log in using the following credentials.
Setting Value
Password vsphere_admin_password
51
2. From the Home menu, select VMs and Templates.
3. Expand the lax01w01vc01.lax01.rainpole.local vCenter Server.
4. Right-click the lax01-w01dc data center and select New Folder > New VM and Template Folder.
5. Create a folder and label it VM T empl at e s .
6. Navigate to Menu > Content Libraries.
7. Click lax01-w01cl-vra01> Templates.
8. Right-click the windows-2012r2-64 VM Template and click New VM from This Template.
The New Virtual Machine from Content Library wizard opens.
9. On the Select name and location page, use the same template name.
Note Use the same template name to create a common service catalog that works across different
vCenter Server instances within your data center environment.
10. Expand the lax01-w01dc data center, select VM Templates as the folder for this virtual machine,
and click Next.
11. On the Select a resource page, expand cluster lax01-w01-comp01, select the lax01-w01rp-user-vm
resource pool, and click Next.
12. On the Review details page, verify the template details, and click Next.
13. On the Select storage page, select the lax01-w01-lib01 datastore and Thin Provision from the
Select virtual disk format drop-down menu and click Next.
14. On the Select networks page, select lax01-w01-vds01-management for the Destination Network,
and click Next.
Note vRealize Automation changes the network according to the blueprint configuration.
15. On the Ready to complete page, review the configurations you made for the virtual machine, and
click Finish.
A new task for creating the virtual machine appears in the Recent Tasks pane. The new virtual
machine is created after the task finishes.
16. Repeat this procedure for all the VM templates in the content library.
Procedure
1. Log in to the Compute vCenter Server by using the vSphere Client.
a Open a Web browser and go to http s:/ /l a x0 1w 01v c0 1 .l ax 0 1. r ain pol e .lo ca l/ ui .
b Log in using the following credentials.
Setting Value
Password vsphere_admin_password
52
2. From the Home menu, select VMs and Templates.
3. In the Navigator pane, expand lax01w01vc01.lax01.rainpole.local>lax01-w01dc> VM Templates.
4. Right-click the windows-2012r2-64 virtual machine located in the VM Templates folder, and
click Template > Convert to Template.
5. Click Yes and confirm the template conversion.
53
16 Configure Single Machine Blueprints
Virtual machine blueprints determine the attributes of a virtual machine, the manner in which it is
provisioned, and its policy and management settings.
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
In the New Service page, configure the following settings and click OK.
Setting Value
Status Active
54
Blueprint Name VM Template Customization Reservation Policy
Specification
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
Setting Value
Archive (days) 15
8. Select and drag the vSphere (vCenter) Machine icon to the Design Canvas.
9. Click the General tab, configure the following settings, and click Save.
55
Setting Default
10. Click the Build Information tab, configure the following settings, and click Save.
Setting Value
Action Clone
Note If the value of the Clone from setting does not list windows-2012r2-64 template, you must
perform a data collection on the lax01-w01-comp01 Compute Resource.
11. Click the Machine Resources tab, configure the following settings, and click Save.
CPU 2 4
12. In the Categories section of the page, select Network & Security to display the list of available
network and security components.
a Select the Existing Network component, drag it onto the Design Canvas and click the Existing
network component from design canvas.
b Under the General tab, click the browse icon and select the Ext-Net-Profile-Production-Web
network profile and click Save.
56
Blueprint Name Existing network
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
57
2. Select the Administration tab and navigate to Catalog Management > Catalog Items.
3. On the Catalog Items pane, select the Windows Server 2012 R2 - LAX Prod blueprint in the
Catalog Items list and click Configure.
4. On the General tab of the Configure Catalog Item dialog box, select LAX Service Catalog from
the Service drop-down menu, and click OK.
5. Associate the blueprint with the Prod-SingleVM-Entitlement entitlement.
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
2. Click the Catalog tab, click Click here to apply filters, and select LAX Service Catalog from the
catalog of available services.
3. Click the Request button for the Windows Server 2012 R2 - LAX Prod blueprint and click Submit.
4. Verify that the request finishes successfully.
a Open a Web browser and go to http s:/ /l a x0 1w 01v c0 1 .l ax 0 1. r ain pol e .lo ca l/ ui .
58
b Log in using the following credentials.
Setting Value
Password vsphere_admin_password
6. Verify that the virtual machine provisions in the shared edge and compute cluster.
59
17 Configure Unified Single Machine Blueprints for
Cross-Region Deployment
To provision blueprints from a specific vRealize Automation deployment to multiple regions, you define the
additional regions in vRealize Automation, and associate the blueprints with those locations.
Procedure
1. Log in to vCenter Server by using the vSphere Client.
a Open a Web browser and go to http s:/ /sf o0 1 m0 1 v c0 1. sfo 0 1. r ain pol e. l oc al /ui .
b Log in using the following credentials.
Setting Value
Password vsphere_admin_password
2. Open a VM console to the IaaS Web server virtual machine vra01iws01a, and log in using
administrator credentials.
3. Add the data centers for the two regions of the SDDC.
60
Associate compute resources with a location
Each data center location has its own compute resources, which you associate with that site for its
dedicated use.
Repeat this procedure two times, for each vCenter Server compute cluster and region.
SFO sfo01-w01-comp01
LAX lax01-w01-comp01
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
61
Setting Value
Domain rainpole.local
Note The property definition name is case-sensitive, and must exactly match the property name
used in the blueprint or the build profile.
b Enter S el e ct a R egi on in the Label text box.
c In the Visibility section, select the All tenants radio button and specify to which tenant the
property is available.
d (Optional) Enter a property description in the Description text box.
Describe the intent of the property and any information that might help the consumer best use the
property.
e Leave default setting for Display order.
f Select String from the Data type drop-down menu.
g Select Yes from the Required drop-down menu.
h Select Dropdown from the Display as drop-down menu.
i Select the Static list radio button for Values.
j Deselect Enable custom value entry.
k Click New in the Static list area and enter a property name and value from the following table.
Name Value
62
Setting Value
Name Vrm.DataCenter.Location
Encrypted Deselected
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
a Click New.
b Type Un if i ed Bl ue pr int - Po li c y in the Name text box.
c Select Reservation Policy from the Type drop-down menu.
d Type R es e rv at ion po li c y f o r Un ifi ed B lu ep r int in the Description text box.
e Click OK.
63
Region Business Group Reservation Reservation Compute Resource.
Name Policy
Procedure
3. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
4. Navigate to Infrastructure > Reservations > Reservations and click New > vSphere (vCenter).
5. On the New Reservation - vSphere (vCenter) page, click the General tab, and configure the
following values.
Name SFO01-Comp01-Prod-UnifiedBlueprint
Tenant rainpole
Priority 100
64
7. On the New Reservation - vSphere (vCenter) page, click the Network tab.
Select the following network path check boxes and select the corresponding network profiles
for the Production business group whose reservation you are configuring.
vxw-dvs-xxxxx-Production-Web-VXLAN Ext-Net-Profile-Production-Web
vxw-dvs-xxxxx-Production-DB-VXLAN Ext-Net-Profile-Production-DB
vxw-dvs-xxxxx-Production-App-VXLAN Ext-Net-Profile-Production-App
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
a In the New Service dialog box, enter U nif ie d S ing le M ach ine C at al og in the Name text
box.
b Select Active from the Status drop-down menu.
c Click OK.
65
Create an entitlement for the unified blueprint catalog
Entitle all blueprints in the unified blueprint catalog to the production business group. Entitlements
determine which users and groups can request specific catalog items or perform specific actions.
Entitlements are specific to a business group, and allow users in different business groups to access the
blueprint catalog.
Perform this procedure and associate the Unified Blueprint Catalog with the Prod-SingleVM-Entitlement
entitlement.
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
2. Associate the Unified Blueprint Catalog with the Prod-SingleVM-Entitlement entitlement that you
created earlier.
66
Blueprint Name VM Template Reservation Customization Service Catalog
Policy Specification
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
Domain rainpole.local
Setting Value
Archive (days) 15
4. Select and drag the vSphere (vCenter) Machine icon to the Design Canvas.
5. Click the General tab, configure the following settings, and click Save.
Setting Value
67
Setting Value
6. Click the Build Information tab, configure the following settings, and click Save.
Setting Value
Action Clone
7. Click the Machine Resources tab, configure the following settings, and click Save.
CPU 1 4
a Select Network & Security in the Categories section and display the list of available network and
security components.
b Select the Existing Network component and drag it onto the design canvas.
c Click in the Existing network component in the Design Canvas, click the Browse icon, and select
the Ext-Net-Profile-Production-Web network profile under General tab.
d Click Save.
e Select the vSphere_Machine properties from the design canvas.
68
f Click the Network tab, click New, configure the following settings, and click OK.
Setting Value
Network ExtNetProfileProductionWeb
a In the Catalog Items list, click the blueprint labeled Windows Server 2012 R2 - Unified.
b In the Configure Catalog Item dialog box, set Service to Unified Single Machine Catalog, and
click OK.
Procedure
1. Log in to the vRealize Automation Rainpole portal.
Setting Value
Password vra-admin-rainpole_password
69
Setting Value
Domain rainpole.local
2. Select the Catalog tab, select Click here to apply filters, and click Unified Single Machine Catalog
from the catalog of available services.
3. Click the Request button for one of the blueprints.
4. Select vSphere_vCenter_Machine_1.
5. Select San Francisco from the Select a Region drop-down menu, and click Submit.
6. Click Submit.
7. Verify the request finishes successfully.
a Open a Web browser and go to ht tp s:/ /sf o0 1w 01v c0 1 .sf o0 1. r ai npo le .lo ca l/ ui .
b Log in using the following credentials.
Setting Value
Password vsphere_admin_password
9. Verify the virtual machine provisions in the Region A vCenter Server compute cluster.
70
A.1 Appendix A - Troubleshooting
In many cases a failed task can be mitigated by logging into the system where the task was being
performed and either observing the current state and log information that may be present from the failed
effort, or by attempting to perform the task manually and observing the result.
Cloud Build can detect the presence of the corrected task and continue its execution flow.
71