CALL CENTER 920002985

GPC1845-60

Why GULFPOWER?

 Proudly a Saudi Product

GULFPOWER Generator set are


proudly assembled in Saudi Arabia
with the highest quality by being
the first Generator set factory in
Saudi Arabia achieving the SASO
certificates and supporting the
local content in line with the Saudi
2030 Vision.
Standby Prime
 Single Source Responsibility 60Hz
kVA kW kVA kW
GULFPOWER provides one-source
responsibility for the Diesel 400V 1845 1476 1605 1284
Generator Sets , Panels ( ATS , Sync ,
MDB) , accessories ( Fuel systems,
Tanks , Cables … etc.,, ) , Generator
380V 1845 1476 1605 1284
set rental , Special studies , turnkey
installation project And Strong *The above ratings represent the performance according to conditions
specified in ISO 8528/1, ISO 3046/1:1986, and BS5514/1. Derating may
qualified engineers to support you
be required for conditions outside these; consult GULFPOWER for further
with the best solutions. info.

 Generator set designed for the Ratings Definition


harsh environment • Emergency standby power (ESP)
Applicable for supplying power to varying electrical load for
the duration of power interruption of a reliable utility source.
GULFPOWER Generator set Emergency Standby Power (ESP) is in accordance with ISO
designed to handle the harsh 8528. Fuel Stop power in accordance with ISO 3046, AS 2789,
weather in MENA regain specially in DIN 6271 and BS 5514.
Saudi Arabia, GCC and Egypt (hot
• Prime power (PRP)
weather and high humidity)
Applicable for supplying power to varying electrical load for
unlimited hours. Prime Power (PRP) is in accordance with ISO
 Product with our own design 8528. Ten percent overload capability is available in
accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514
GULFPOWER has its own R&D and
engineering team to make the * This Generator set is built in ISO 9001 certified facility
perfect design for Generator set
matching the customer
requirements.
CALL CENTER 920002985

Engine Specification:
Engine Make Cummins
Engine Model KTA50-G9
Engine Speed 1800 RPM
Max. Gross Power 1605 KW
Engine Type 4-Cycle; 60° Vee; 16-Cylinder Diesel
Aspiration Turbocharged & Low Temp. After cooled
Bore and Stroke (6.25 x 6.25) Inch 159 x 159 mm
Displacement 50.3 Liter
Compression Ratio 13: 9 : 1
Dry Weight – Fan to Flywheel Engine (Approximate) 5360 kg
EXHAUST SYSTEM
Maximum Back Pressure 51 (mm Hg)
COOLING SYSTEM
Jacket Water Circuit Requirements
Coolant Capacity – Engine only without radiator 140 L
Standard Thermostat (Modulating Range) 82 - 93 °C
Maximum Top Tank Temperature 104 0C
Minimum Pressure Cap 96 kpa
LUBRICATION SYSTEM
Oil Capacity with Standard Oil Pan : Low – High 178– 148 Liter
Total System Capacity 204 L
ELECTRICAL SYSTEM:
Starting Motor 24 Volts
FUEL SYSTEM
Injection Type Direct injection Cummins PT
Fuel Injection Pump Direct injection Cummins PT
Governor Electronic Speed governor

Alternator Specification:
Make Stamford
Model PI734-C W13
Type Brushless
Excitation System Self-Excited With PMG
Voltage Regulation ±1%
Insulation Class Class H
Temperature Rise Class H
Stator Winding Double layer LAP
Winding Pitch 2/3
IP protection IP23
Bearings Single
Over speed 125%
Standards BS5000-3, NEMA MG1-32,
ISO8528-3, CSA C22.2 100
CALL CENTER 920002985

FUEL CONSUMPTION CONTROL PANEL


% Liter/ hour US Gal/ hour
STANDBY POWER
100 392 103.6
PRIME POWER
100 330 87.3
75 257 68.0
50 180 47.6

Digital Controller:
These controllers are easy to use and
Standard Features feature
 Lead acid Batteries An intuitive user interface with graphic
 Battery charger. Display. The built-in event and
performance
 Forklift Opening & Crane Lifting Point.
Log with backed-up real time clock
 Auto-Manual digital Controller.
makes
 Anti-Vibration Mounting between Engine/Alternator and skid. Troubleshooting even simpler.
 3 Pole Circuit Breaker. o 3 phase generator protections
 Industrial grade silencer for Open Type set. o True RMS current measurement
 Critical grade silencer for the Close type. o Power Measurements
o Event Performance log + RTC
Optional: o User Interface
 Synchronization Control panel – different Varieties. o Communication Interfaces
 Four Pole Circuit Breaker. * Please refer to Data sheet for details.
 Critical / Hospital Grade Silencer for Open Type Set.
 Annunciator Panel.
 Anti-condensation Heater
 Jacket Water Heater.
 Alternator Winding Temperature Sensor.
 Bearing Temperature Sensor.

DIMENSIONS AND WEIGHT


InteliGen 200
Canopy Type Dimension: W= 2800, H=3500, L = 8300 mm
Open Type Dimension: W= 2155 H= 2936, L = 5587 mm Is a comprehensive controller for both single
and multiple gen-sets operating in standby or
Open Type Weight: 11246 Kg parallel mode.
Canopy Type Weight: 28410 Kg approx
Without Base Tank • Automatic synchronizing and Power control
• Base load Import/ Export
• Peak shaving
• Integrated PLC programmable functions
NOTE: Contact GULFPOWER team for more detailed information about
• Event based history
Generator set dimension.
* Additional Controlling solution are
available, please consult GULFPOWER team
for more information.