Factory Automation Cable

KDF
KURAMO Durable Robot Cable

UL AWM 2103/2517
Characteristics Radar Chart
Heat resistance
5

4
Cable carrier Oil resistance
resistance 3

2 Features
1 ■ Fluorocarbon resin insulation/Bending resistance
0 ■ Heat resistance
left/right
Noise ■ Mat sheath
bending
resistance
resistance ■ Cable designed to UL, cUL standards

45°left/right vibration
Twist resistance
resistance

Application
KDF General VCT
※The characteristics of the cable indicated on the radar chart are intended for ■ Cable carrier wiring
use as a general guide for selecting the cable meeting your requirements. ■ Cable connection to robot arm swinging part

Certification

Electrical Characteristics
Nominal Cross-Sectional Number of Pairs Allowable Current(A)
Item
Area(Ý)(AWG) 1∼30P 1P 2P 3P 4P 5P 6P 7P 8P 9P 10P 12P 15P 20P 25P 30P
Conductor Resistance 0.2 (25) 105 6 5 4 4 4 4 4 3 3 3 3 3 2 2 2
(20℃) 0.3 (23) 71.5 8 7 6 5 5 5 5 4 4 4 4 4 3 3 3
Ω/Ü or below 0.5 (21) 43.4 11 9 8 7 7 7 7 6 6 6 6 5 5 4 4
Insulation Resistance 0.2(25)∼
1500
MΩÜ or above 0.5(21)
Test Voltage V・min AC 2000V
●Allowable Current (A) for the cable is based on calculation under aerial one-cable
installation at ambient temperature of 30℃, not representing a guaranteed value.
Allowable current for the cable at ambient temperature above 30℃ is to be determined
by multiplying the current value by the appropriate current reduction factor specified in
the following table for the ambient temperature.

■ Current Reduction Factor Table


Ambient Temperature(℃) 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Current Reduction Factor 1.00 0.97 0.93 0.89 0.86 0.82 0.77 0.73 0.68 0.63 0.58 0.52 0.45 0.36 0.26

65
Technical Data
UL・cUL
Size 2pairs or less×0.2-0.5Ý 3pairs or more×0.2-0.5Ý
Voltage Rating 300V
Temperature Rating 105℃
Test Voltage AC2000V・1min
Flame Resistance FT2 VW-1, FT1
Applicable Standard UL AWM Style 2103 CAN/CSA-C22.2 No210.2 UL AWM Style 2517 CAN/CSA-C22.2 No210.2
The KDF cable, when applied in compliance with the standards in Japan, can be used for cable connection to signal and communication circuits

KDF
and other weak current electrical circuits.

Cable Outside Diameter/Weight


Nominal cross-sectional area(Ý)<AWG> Number of Pairs
Conductor count/wire diameter 1P 2P 3P 4P 5P 6P 7P 8P 9P 10P 12P 15P 20P 25P 30P
0.2 (40/0.08) 3.5 5.7 6.2 6.4 7.2 7.7 8.0 8.8 9.4 10.5 11.5 11.0 12.0 14.0 17.5
※ ※
<25> 17 37 46 50 60 70 80 90 100 115 135 145 190 240 330
0.3 (3/20/0.08) 4.1 6.8 7.3 8.1 8.7 9.5 10.0 11.0 11.5 12.5 14.5 14.0 15.5 17.5 21.5
※ ※ ※
<23> 24 50 60 75 90 100 115 130 145 170 210 230 290 370 490
0.5 (3/33/0.08) 4.7 7.9 8.9 9.8 11.0 11.5 12.5 13.5 14.5 16.0 17.5 17.0 19.5 21.0 28.0
※ ※ ※
<21> 30 70 90 110 135 160 180 205 230 280 330 350 460 550 720
KDF cable, which is exempt from the application of the Electrical Appliance and Upper: Standard cable outside diameter(Approx.Ù)
Material Safety Law, can be used for cable connection to signal and communi- Lower: Approximate weight(è/Ü)
cation circuits and other weak current electrical circuits in Japan. ※ indicates specifications for custom order production.
●If any conventional products of this series are in stock, there may be a period
required for transition to their UL/cUL compliant counterparts.

<PS>E
UL AWM
NFPA79
NFPA70
CE
CCCcUL/CSA
GOST-R

66
KDF KURAMO Durable Robot Cable

Cable Construction (applicable to 1-25P)


Item 0.2Ý 0.3Ý 0.5Ý
Conductor Tin-plated soft annealed stranded copper Tin-plated soft annealed stranded copper composite
Insulator Fluorocarbon resin (ETFE)
Conductor stranding Twisted pair
Pair stranding Circular
Core wrapping tape Tape wrap around cores
Sheath Heat resistant PVC (black)

Core Identification (applicable to 1-25P)


Pair No. 1 2 3 4 5 6 7 8 9 10 11 12 13
Class 1 Conductor (L1) Blue Yellow Green Red Purple Blue Yellow Green Red Purple Blue Yellow Green
Class 2 Conductor (L2) White Brown Black Gray Orange Brown Black Gray Orange White Black Gray Orange
Pair No. 14 15 16 17 18 19 20 21 22 23 24 25
Class 1 Conductor (L1) Red Purple Blue Yellow Green Red Purple Blue Yellow Green Red Purple
Class 2 Conductor (L2) White Brown Gray Orange White Brown Black Orange White Brown Black Gray

■ Example: 8 cores (4pair) 0.3Ý cable

Pair stranded conductor

L1 Class 1 conductor (L1)

L2 Class 2 conductor (L2)

Tape
Conductor

KDF KURAMO 耐久性ケーブル(耐屈曲 耐熱 耐油型)0.3Ý LF


KURAMO E162205-K AWM STYLE 2517 Ⅰ A/B 105C 300V VW-1 FT1 23AWG

Insulator Sheath

Conductor Layout (applicable to 1-25P)

1P 2P 3P 4P 5P 6P 7P 8P

1 1 1
1 1 7 2 8 2
1 1 5 2 6 2
1 4 2 6 3 7 3
2 3 2 3 4 3 5 3
4 5 4 6 4
5

9P 10P 12P 15P 20P 25P


16 1 2
12 1 2 13 1 2
10 1 2 10 1 2 15 17 3
9 1 2 11 3 12 14 3 14 25 18 4
9 3 9 15 11 12 3 20 15
8 3 10 4 11
19 16
4 13 24 19 5
8 4 8 14 13 4
7 4 9 5 10 18 17 5 12 23 20 6
7 6 5
6 5 8 7 6 7 6 5 9 6 11 22 21 7
8 7 10 9 8

67
Cable Construction (applicable to 30P)
Item 0.2Ý 0.3Ý 0.5Ý
Conductor Tin-plated soft annealed stranded copper Tin-plated soft annealed stranded copper composite
Insulator Fluorocarbon resin (ETFE)
Conductor stranding Twisted pair
Pair stranding Circular (5P) into unit
Unit stranding Circular (6 units)
Core wrapping tape Tape wrap around cores
Sheath Heat resistant PVC (black)

KDF
Core Identification (applicable to 30P)
Pair stranded conductor
■ 5P identification
Pair No. 1 2 3 4 5 L1 Class 1 conductor (L1)
Class 1 Conductor (L1) Blue Yellow Green Red Purple
Class 2 Conductor (L2) White Brown Black Gray Orange L2 Class 2 conductor (L2)

■ Unit identification
Unit No. 1 2 3 4 5 6
Tape Color Blue Yellow Green Red Purple White

Conductor Layout (applicable to 30P)


■ 5P layout
Pair No. 1 2 3 4 5
1
5 2
Class 1 Conductor (L1) Blue Yellow Green Red Purple
Class 2 Conductor (L2) White Brown Black Gray Orange 4 3

■ Unit layout 1
Unit No. 1 2 3 4 5 6 6 2
Tape Color Blue Yellow Green Red Purple White 5 3
4 <PS>E
UL AWM
NFPA79
NFPA70
CE
CCCcUL/CSA
GOST-R