Custody Transfer System For

LNG Bunkering Vessels

MUSASINO CO., LTD. Distributor:


□Head Office
1-2-15 MinamiYukigaya, Ota-ku, Tokyo, 145-0066
Tel.+81-3-3726-4413 Fax.+81-3-3726-1557
E-mail:[email protected] / [email protected]

https://www.musasino.biz
Work Station
Custody Transfer System For
Monitor

LNG Bunkering Vessels


Musasino’s Custody Transfer Systems for LNG bunkering vessels pack extensive experience in the
marine industry and unique technologies into an all-in-one structure, using a one-inch radar guide Network Panel

pipe. LOCAL ALARM

FEATURES Inclinometer

1 Unique Self-Correction Function


The radar type liquid level sensors are equipped with a self-calibration function that ensures accurate
measurements over long-term operation.
Non-Hazardous Area
2 All-in-One Structure
The all-in-one design combines modules for level sensors, temperature sensors, and pressure sensors Hazardous Area
in a single housing. Each module is independent, and can be maintained without having to open the
Local Indicator Radar Type Level Gauge
tank. Musasino’s in-house developed transducer makes it possible to take stable measurements with - Level Gauge (Primary / Secondary)
- Temperature max. 4 points (Primary / Secondary)
less attenuation and less interference from any unevenness in the guide pipe. - Pressure
- Overfill Alarm. 1 point

3 Japan’s First Natural Gas Calorific Value Calculation Software


The software uses various data from custody transfer system reports and LNG composition to
calculate the volume of natural gas into its calorific value, which is output in the Bunker Delivery
Note.
Level Gauge Temperature Sensor
4 Bottom Structure Measuring Method FMCW Method PT-100, 4-wire Temperature Sensor
(Frequency Modulated Continuous Wave) Measurement Range -200 to +100°C
The bottom attenuator has unique and simple design, which, depending on the tank type, can be
Measurement Range 0.5m ∼ 25m Accuracy ±0.2°C (≤-145°C), ±1.5°C (>-145°C)
installed directly on the guide pipe to eliminate the need for extensive installation work inside the tank. 1mm
Resolution Resolution 0.1°C
Accuracy ±5mm
5 Designed for Durability Ambient Temperature -30 to +70℃ (Electronics Housing) Pressure Sensor
The inside of an LNG tank is a harsh environment, and the installation has to hold up under those Explosion Protection Intrinsically Safe Type Ex ia ⅡC T5 Method Diaphragm with Strain Gauge Bridge
conditions for decades. Simulations using sloshing models show our design is robust enough to Protection Class IP66 Measurement Range 0.8 bar ∼ 4.6 bar
Material SUS316L Accuracy ±0.5% FS
withstand over 40 years of operations.
Resolution 1 mbar
Inclinometer Diaphragm Material SUS 316L
Method Capacitive MEMS Sensor
Measurement Range ±5°
Accuracy ±0.05°
Resolution 0.001°

You might also like