0% found this document useful (0 votes)
12 views

Specification Sheet MIT510

The document describes a 5 kV insulation resistance tester. It can test equipment powered by mains or battery and has automatic and manual test modes. It measures resistance from 10 kΩ to 15 TΩ and has safety features to prevent testing if voltage is over 50V.

Uploaded by

Ali Babar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views

Specification Sheet MIT510

The document describes a 5 kV insulation resistance tester. It can test equipment powered by mains or battery and has automatic and manual test modes. It measures resistance from 10 kΩ to 15 TΩ and has safety features to prevent testing if voltage is over 50V.

Uploaded by

Ali Babar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

To buy, sell, rent or trade-in this product please click on the link below:

http://www.avionteq.com/Megger-MIT510-5-kV-Insulation-Resistance-Tester.aspx

MIT510
5 kV Insulation Resistance Tester

www.avionteq.com
MIT510
5 kV Insulation Resistance Tester

■ Mains or battery powered


■ Digital/Analogue backlit display
■ Selectable test voltage from 500 to 5000V
■ Automatic IR test
■ Measures to 15 TΩ
■ Complete with calibration certificate

DESCRIPTION To further enhance the flexibility of the instrument the


MIT510 has the facility to set the test voltage in steps from
The new 5 kV insulation resistance testers from Megger 500 V to 5000 V avoiding the expense of several insulation
are designed specifically to assist you with the testing and resistance testers to meet your application needs.
maintenance of high voltage electrical equipment. The
case is incredibly rugged and easy to carry, being made of The IR tester is designed to meet the highest safety
tough polypropylene and achieving an ingress protection standards and meets the requirements of EN61010. In
rating of IP54. In addition, the model number is marked addition, the instrument measures the voltage at the
on both the top and side of the case for ease of terminals and if this is above 50V then the instrument will
identification in stores or vehicles. display the high voltage warning and inhibit testing. At the
end of the test the instrument will automatically discharge
The instrument has a large easy to read backlit LCD the energy transferred to the equipment during the test
display making it equally suitable for use in both bright phase.
sunlight and poorly lit environments. Information
displayed includes resistance, voltage, leakage current,
capacitance, battery status and time constant. In addition,
the elapsed time of the test is displayed constantly
removing the need for separate timers.

The instrument can test when being powered by the


mains or its internal rechargeable battery, a great benefit
when site conditions are unknown or long term testing is
required.

The controls of the instrument are clear and unambiguous


and a "quick start" guide is included in the lid of the
instrument removing the need to carry bulky manuals
under site conditions.

The instrument is fitted with a guard terminal to enhance


accuracy. The guard test lead is included as standard with
the instrument.
KF-LAB, KF875 and KF-UNI
Karl Fischer Moisture in Oil Test Sets

ELECTRICAL SPECIFICATIONS
Three leads with compact clamp, flexible silicon insulated.
Voltage input range:
85-260 V, 50/60Hz
Environmental
Battery life:
8 hours continuous testing at 5 kV Operating temperature:
-10°C to 55°C
Test voltages:
500 V, 1000 V, 2500 V, 5000 V Storage temperature:
-20°C to 70°C
Accuracy (23°C):
±5% to 100 GΩ Ingress protection (lid closed):
±10% to 15 TΩ IP54
Display range: Humidity:
Digital display 10 kΩ to 15 TΩ 90% RH non-condensing at 40°C
Analogue display 100 kΩ to 1 TΩ
Short circuit/charge current:
3 mA
Capacitor charge time:
≤5 seconds per µF at 3 mA
Capacitor discharge time:
≤5 seconds per µF to discharge from 5000 V to 50 V
Capacitance measurement:
1nF to 50 µF (measured with test voltage ≥ 500 V)
Capacitance measurement accuracy (23°C):
±5% ±5 nF
Voltage output accuracy (0°C to 30°C):
±2% ±1 V of nominal test voltage at 100 MΩ load
±25 V for test voltages less than 500 V
Current measurement range:
±0.01 nA to ±5 mA
Current measurement accuracy (23°C):
±5% ±0.2 nA at all voltages
Display:
Analogue/Digital 3 digits
Interference rejection:
1mA rms per kV test voltage, 2 mA rms maximum
Timer range:
Up to 99 minutes
Test regimes
Auto IR

ORDERING INFORMATION
Item (Qty) Order Code
5kV insulation resistance tester MIT510

Included Accessories
3m lead set 8101-180
User guide on CD-ROM

Optional Accessories
3m lead set with straight jaw clamps