EE213 - EndSems
EE213 - EndSems
Note: Read the Instructions carefully before answering all the questions.
Instructions:
1) Answer all the questions.
2) This question paper has 3 pages.
3) Proper steps should be written for each answer.
4) Write neatly and legibly.
5) Exchange of Caleulators are not allowed in the exam hall
6) Mobile Phones are not allowed inside the exam hall; it is a punishable offence
if any student is found with a mobile phone.
7) Write
your name and roll no in the graph sheets provided.
I of 3
0.15 2 0.4 2
V 800 S 400 2 V2
Figure.1
Q3 Figure.2 shows the cross section of a rectangular iron core with two
airgaps g1 and g2. The ferromagnetic iron can be assumed to have
infinite permeability. The coil has 500 turns.
(a) Gaps g and g2 are each equal to 0.1cm and a current of 183 (4 marks)
A flows through the winding. Compute the flux densities in the
two air gaps, Bgi in the center gap 91 and Bg2 in the end gap
92
(b) Let gap g2 be now closed by inserting an iron piece of the (1 mark)
cortect size and infinite permeability, so that only the center
gap 910.1 cm remains. Ifa flux density of 1.25 T is needed
in gap g1,find the current that is needed in the winding.
-92
91
Figure.2
2 of 3
Q4 A 75 kW, 440 V, 3-phase, 6-pole, 50 1z, wound-rotor induction
motor has a full-load slip of 0.04 and a sip at maximum torque of 0.2
when opcrating at rated voltage and frequcncy with rotor winding
short-circuited at the slip-rings. Assume the stator resistance and
rotational losses are negligiblc. Find:
(a) Maximum torque (2 marks)
(b) Starting torque (2 marks)
(c) Full-load rotor copper loss. (1 mark)
has a Y-connected
Q6 A 1.1 kV, 50 Hz, A-connected induction motor
The rotor
slip-ring rotor with a phase transformation ratio of 3.8.
resistance and rotor standstill leakage reactance are 0.012 Q and 0.25
and
2per phase, respectively. Neglecting stator impedance
magnetizing current, determine the following:
external rotor
a) With referred to the stator side, find the
line
resistance/phase to be added to the rotor when the starting
current drawn from the supply is 100 A. (3 marks)
The rotor current at 4 per cent slip with slip ring shorted. (I mark)
b)
The rotor current at the starting with slip rings are shorted. (1 mark)
c)
Q7 A 14 kW 3-0, A-connected 400 V, induction motor gave the
following results:
No-load test: 400 V, 1.2 kW, 8 A
Short-circuit test: 150 V, 3.9 kW, 36 A
The rotor copper loss at standstill is half the total copper loss.
Draw the circle diagram and determine the
a) Full-load value of the current, ratio of maximum torque to the full- (10 marks)
3 of 3