Power Units

Premium Hydraulic Performance


Our custom built, job specific power unit replacements can enhance virtually any hydraulic application.
Three new horsepower motors have been added to our product line which allows for a wider range of
application needs. The superior cast design and precise operation of our power units increase the
leveling accuracy and improve passenger safety. Nothing compares with the smooth, quiet ride that only
a Vertical Express Power Unit and I-Series® Valve provides.

Quality hydraulic power units.


At Vertical Express, we pride ourselves in adhering to the
highest standard of quality. Our exclusive valve, silencer
and motor designs contribute to the overall dependability
and outstanding performance of the best-selling hydraulic
power unit on the market. Dry Power Unit

Hydraulic elevators only perform as well as the valve.


The valve governs the flow of oil through your elevator’s hydraulic system. If
the flow of oil is erratic, the performance of your elevator will be as well
causing your elevator to level improperly. The I-Series by
Vertical Express is the solution. The pistons in our I-2
and I-3 valves, which vary in size and speed, regulate oil
flow to and from the hydraulic jack. They are machined
with such precision that internal O-rings are not needed,
reducing friction and making the operation of the elevator
smoother, quieter and more consistent. I-2 Valve

Silence is golden.
Vertical Express’ silencer is a time-proven hydraulic vibration dampening system.
This unit can be integrated into the power unit or mounted outside to effectively
remove vibrations that may otherwise be felt by passengers inside the car.

Power units created precisely for you.


Each and every power unit is built according to the options you choose and
Silencer then pre-adjusted and tested specifically for your job conditions. Shutoff valves,
pipe stand assemblies, Victaulic® couplings and other accessories can be shipped with your power unit at
your request. We also pre-wire your power unit terminals for easy field connection to solenoids and motor.

Tested for Accuracy


Before every Vertical Express valve leaves our U.S. manufacturing facility, it is tested to ensure that there
are no leaks and that it meets pressure and load requirements. A custom-built welded manifold ties the
valve to the power unit. The manifolds are tested to twice the working pressure of the jack to ensure
proper functionality. Contact your local Vertical Express sales representative or call 866-448-3789.
Power Units
For Vertical Express Contractor Use Only
Once complete, fax to (901) 261-1807. Be sure to include all surveys.
Office: _____________________________________ Date: __________________ By: ____________________________________
Job Name: _______________________________________________ Job Number: _________________________________________
PO Number: ______________________________________________ Tel: _________________________________________________
To place a direct order, call (866) 448-3789.
Select Required:
c AP Power Unit (Dry Unit) c 2” Shut-off Valve (less than 215 GPM) Qty: _____________
c EP Power Unit (Submersible Unit) c 3” Shut-off Valve (over 215 GPM) Qty: _____________
c Viscosity Control c Isolation Coupling Qty: _____________
c Oil Cooler c Constant Lowering Speed (Maxton)
c Overspeed/Rupture Valve c Loadweigher Pressure Switch
c Inline c 90° c Tank Shut-off Valve for Isolation of Oil
c Seismic Requirements c Low Pressure Switch
c Canadian B44 Code c High Pressure Switch
c 80 Starts Per Hour c Glass Oil Level Sight Gauge
c 120 Starts Per Hour

Data Required:
General: Power Unit:
Car Speed: _________________________________________ Gross Load on Power Unit: _____________________________
Capacity: ___________________________________________ Pump Size: _____________________________________ GPM
Car Weight: _________________________________________ Rise: ______________________________________________
Controller: Loading Class: ______________________________________
c New (TAC22) Oil Line Size: ________________________________________
c Retain Existing Controller Oil Line Type: c Victaulic c Threaded (NPT)
Type: __________________________________________ Oil Type: c Petroleum c Synthetic
Solenoid voltage: _________________________________ Existing Data:
c AC c DC Motor HP: __________________________________________
Main Line Voltage: ___________________________________ Voltage: ____________________________________________
Phase: _____________________________________________ Amps: _____________________________________________
Jack: Static Pressure: ______________________________________
Piston Diameter: _____________________________________ Relief Pressure: ______________________________________
Number of Jacks/Elevators: ____________________________
Machine Room Location:
c Adjacent c Overhead c Below (requires Pressure Switch) c Remote - Distance: __________________

Hand of Unit:
c Standard c Non-standard
Junction
Junction Box
Box

Oil Oil
Outlet Outlet

Vertical Express
P.O. Box 2019 Memphis, TN 38101 Tel: (866) 448-3789 (toll-free) Fax: (901) 261-1807 www.verticalxpress.com
All illustrations and specifications are based on information in effect at the time of publication approval. Vertical Express reserves the right to change
specification or designs and to discontinue items without prior notification or obligation. v.7.6. Copyright © 2007 Vertical Express Elevator