A100 LED Status
A100 LED Status
I/O Device Terminal Symbol DESCRIPTION PRE START STATUS RUN STATUS
0 X24 9 S422 WATER PRESSURE CONTROL 1 0
1 X24 8 S421 AIR PRESSURE CONTROL 1 0
2 X500 531 S420 HYD OIL LEVEL CONTROL 1 1
3 X63 4 S501 WATER PUMP AUTO USE 1 1
4 X63 5 S501 WATER PUMP MAN USE (START) 0 0
5 X63 6 S502 COMPRESSOR AUTO USE 1 1
6 X63 7 S502 COMPRESSOR MAN USE (START) 0 0
7 X63 8 S505 PRESSURE SWITCH RESET 1 1
8 NOT IN USE 0 0
9 X110 15 HP RUN HYD PUMP RUNNING 0 1
10 F241 96 OVERLOAD WATERPUMP/COMPRESSOR OVERLOAD 1 1
11 X500 538 OIL HOT HYD OIL HOT 0 0
COM X500 501 0VDC 0 0
IN 1Ch
I/O Device Terminal Symbol DESCRIPTION PRE START STATUS RUN STATUS
0 SH520 6 SH520 PRESSURE SWITCH BYPASS (POWER) 0 0
1 X500 512 S423 1 BOOM ROTATION/PERCUSSION ON 0 1
2 X500 529 SLCU SLCU OIL LEVEL LOW 0 0
3 X110 14 DL IDENTIFIER DL APPLICATION 1 1
4 X500 513 2 BOOM ROTATION/PERCUSSION ON 0 1
5 NOT IN USE 0 0
OUT 101
I/O Device Terminal Symbol DESCRIPTION PRE START STATUS RUN STATUS
0 K231 A1 K231 WATER PUMP CONTROL 0 1
1 K241 A1 K241 COMPLRESSOR CONTROL 0 1
NOT IN USE 0 0
3 X500 518 S1 SLCU BOOSTER CONTROL 0 0
COM X110 12 24VDC 1 1