0% found this document useful (0 votes)
48 views2 pages

1VYN401390-131 - 20230651 - ABB - 1VYN401390-131 Rev O - OVR 2pg Flyer - r2

Uploaded by

ricardodtramos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views2 pages

1VYN401390-131 - 20230651 - ABB - 1VYN401390-131 Rev O - OVR 2pg Flyer - r2

Uploaded by

ricardodtramos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DISTRIBUTION SOLUTIONS

OVR three-phase vacuum reclosers


SCADA switch for smart networks

ABB offers a complete range of


three-phase mechanically gang-
operated vacuum reclosers suitable
for distribution networks up to 38 kV
in accordance with IEC 62271-111 and
IEEE C37.60. Advanced protection
functions and communication
protocols make them a more reliable
solution for smart outdoor networks
and substations.

Operator safety at its best Fast installation with easy operation


• Safer and more secure manual and maintenance
emergency trip handle to prevent • Site-ready units reduce installation time,
accidental closing in an emergency effort and cost
situation • Flexible mounting options for single/
• No electronics to maintain in high double pole or substation frame
voltage cabinet available
• Draw-out protection Relion® relay
Reliable in extreme conditions for quick and easy maintenance
• Solid dielectric design with HCEP or replacement
(hydrophobic cycloaliphatic epoxy • Relay configuration and settings
polymer) insulating material helps can be managed from front-panel
ensure superior performance over HMI, web-based user interface or
a longer service period connectivity tool
• Excellent performance even in high- • Integrated current and voltage
pollution environments measurement
• State-of-the-art magnetic actuation • Flexibility in protection relay selection
and vacuum interrupters help maintain
reliable switching performance over
the life of the recloser

01 OVR-15 Applications

• Utility feeder applications: tie point, sectionalizing and load break switch
02 OVR-27
— • Medium voltage circuit breaker replacement for substation applications
03 OVR-38
• Point of interconnection for renewable, DERs and microgrid applications

04 Recloser control cabinet • Three-phase laterals serving industrial and infrastructure customers
with Relion® RER615 IED
• Auto-recloser application for oil and gas customers

05 Recloser control
cabinet with SEL-751 IED

Technical characteristics Units OVR-15 OVR-27 OVR-38


Standards IEC 62271-111 / IEEE C37.60
Nominal operating voltage kV Up to 15 Up to 27 Up to 38
Rated maximum voltage kV 15.5 27 38
Rated power frequency Hz 50/60 50/60 50/60
Rated continuous normal current A 630 1000 1200
Rated short-time current withstand capacity kA 12.5 for 3 sec. 12.5 for 3 sec. 16 for 3 sec.
Rated peak withstand current kAp 31.25 31.25 40
Rated lightning impulse withstand voltage (BIL) kVP 110 125 170
Rated power frequency withstand voltage (1 min. dry) kV 50 60 70
Rated symmetrical interrupting current kA 12.5 12.5 16
Rated line-charging current (LC) / cable-charging A 2 / 10 5 / 25 5 / 40
current (CC)
Rated operating (reclosing) sequence O - 0.2 s - CO - 2 s - CO - 2 s - CO
Minimum operation (CO cycles) at rated Operations 10,000 1
continuous current
Auxiliary power supply voltage V AC 110 / 240
Type of battery pack Sealed lead acid rechargeable
Standard battery bank offering V (Ah) 24 (18) 2
Standard battery back-up Hrs 24 2
Current sensors per recloser 3 numbers current transformer
Voltage sensors per recloser 3 or 6 3 3 or 6 3 3 or 6 3
Interrupting media Vacuum interrupter
Type of mechanism Bi-stable magnetic actuator
Ambient temperature range ˚C -40 to +55
Altitude m 3000 4
Minimum external creepage distance mm (inch) 480 (19) 960 (37.7) 1306 (51)
Weight of HV unit kg (lb) 140 (309) 140 (309) 175 (386)
Controller (IED) Relion® RER615 / SEL-751
1
Contact factory for higher number of operations
2
Higher battery performances available on request
3
Six voltage sensors option available only with RER615 IED
4
For altitudes above 1000 m, suitable de-rating must be considered as per IEC 62271-111/IEC C37.100.1-2007

1VYN401390-131 Rev O September 2023

— — — — —
01 02 03 04 05

— —
ABB Inc. We reserve the right to make technical We reserve all rights in this document
305 Gregson Drive changes or modify the contents of this and in the subject matter and illustrations
Cary, NC 27511 document without prior notice. With regard contained therein. Any reproduction,
to purchase orders, the agreed particulars disclosure to third parties or utilization
shall prevail. ABB Inc. does not accept any of its contents – in whole or in parts – is
­responsibility whatsoever for potential forbidden without prior written consent
errors or possible lack of information in of ABB Inc. ­Copyright© 2023 ABB
abb.com/mediumvoltage this document. All rights reserved

You might also like