GENERAL ELECTRICAL NOTES & DETAILS

1: THE ELECTRICAL INSTALLATIONS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE


19: THE STANDARD SIZE OF WIRE TO BE USED SHALL BE IN METRIC STANDARD (SI UNITS).
PROVISIONS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA70 AND 40: OUTLETS WHEN INSTALLED BACK TO BACK SHALL BE SO PLACED AS SOUND FROM ONE
IEE . ROOM SHALL NOT REACH THE OTHER ROOM.
20: ALL 20 AMPERE CIRCUIT HOMERUNS TO PANELBOARD MORE THAN 38 M. IN LENGTH
2: THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE 415V, 3PH, 50 HERTZ. SHALL BE 6 SQ.MM COPPER UNLESS OTHERWISE SPECIFIED. 41: LOW CURRENT AND COMMUNICATION CABLES SHALL HAVE SEPARATE RACEWAYS & TO BE
SEGREGATED FROM LOW VOLTAGE CABLES.
21: UNLESS OTHERWISE INDICATED, SIZE OF BRANCH CIRCUIT WIRES SHALL BE AS FOLLOWS:
3: THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF EXISTING POWER 42: CIRCUIT BREAKERS SUPPLYING POWER TO AIR HANDLING AND FAN COIL
SUPPLY AND ALSO THE ACTUAL LOCATION OF THE EXISTING TELEPHONE CABLE FACILITIES BRANCH C.B. BRANCH CKT. WIRE UNITS ARE PROVIDED WITH SHUNT TRIP AND ARE INTERLOCKED WITH FIRE ALARM
FOR CONNECTION. 10/15A 2.5 SQ.MM GRD, 2.5 SQ.MM SYSTEM TO - TRIP IN CASE OF FIRE.
PVC 20A 4.0 SQ.MM GRD, 4.0 SQ.MM
4: THE CONTRACTOR SHALL COORDINATE THE LOCATION OF LIGHTING FIXTURES WITH PVC 43: a) ALL CONDUIT RUNS IMBEDDED IN CONCRETE AND CONDUITS INSIDE DOUBLE WALL
MECHANICAL AND OTHER DEVICES TO BE INSTALLED IN CEILING. PARTITIONS TO BE POLYVINYL CHLORIDE (PVC) TYPE.
22: ALL MAIN AND BRANCH BREAKERS OF SWITCHBOARDS TO BE OF INTERCHANGEABLE TRIP
TYPE. b) ALL INDOOR EXPOSED CONDUITS AND CONDUITS INSTALLED ABOVE FALSE
UNLESS OTHERWISE SPECIFIED THE MINIMUM SIZE OF WIRE AND CONDUIT SHALL BE CEILINGS TO BE E.M.T OR RIGID STEEL TYPE.
5: 23: ALL LIGHT FIXTURES IN AREAS SUBJECT TO WET/DAMP LOCATIONS LIKE KITCHEN &
2.5MM SQ COPPER AND 20 MM DIAMETER RESPECTIVELY. C) ALL OUTDOOR EXPOSED CONDUITS TO BE GALVANIZED RIGID STEEL TYPE.
LAUNDRY SHALL HAVE MINIMUM PROTECTION DEGREE OF "IP44".
44:
a) THE MINIMUM SIZE OF THE SHEET FOR DRAWING SHOULD BE A2.
b) SHOP DRAWING SHOULD BE TO SCALE AND DIMENSIONS.
6: ALL SERVICE ENTRANCE EQUIPMENT SUCH AS POWER AND LIGHTING PANELS SHALL BE 24: VERIFY LOCATIONS AND RATINGS OF ALL MECHANICAL EQUIPMENT/THERMOSTATS AT SITE
PROPERLY CONNECTED TO BUILDING earth GRID. AND AS PER MECHANICAL PLANS PRIOR TO EXECUTION OF ELECTRICAL WORKS. c) SECTION , DETAILS AND VIEWS TO BE PROVIDED IN THE SHOP DRAWING.

7: earth ALL METALLIC CONDUITS, STRUCTURAL STEEL SUPPORTS, CABINETS AND EQUIPMENT 45: LIGHTNING AND GROUNDING SYSTEMS WORK TO BE PER JOB AS IN BOQ,
IN ACCORDANCE WITH THE NEC. earth MOTOR BASES AND FRAMES BY PULLING A 25: CONTRACTOR IS TO CHECK ALL VOLTAGE DROP IN SYSTEM AGAINST CABLE SEE THE GENERAL DETAILS DRAWING. THE CONTRACTOR SHALL SUBMIT THE SHOP DRAWING
SEPARATE CONDUCTOR WITH THE MOTOR FEEDER. SIZES/LENGTH. VOLTAGE DROP ANYWHERE IN TOTAL SYSTEM FROM POWER SOURCE TO FOR WORK.
CONSUMER ON EACH CIRCUIT SHALL NOT EXCEED 4% .

8: NON-METALLIC CONDUITS OR DUCTS SHALL CONTAIN AN INSULATED GROUNDING 26: earth RESULT ANYWHERE IN THE SYSTEM SHALL NOT EXCEED 5 OHMS.
CONDUCTOR.
27: CONTRACTOR TO FURNISH VENDOR'S SHOP DRAWING FOR ALL SYSTEMS FOR APPROVAL
9: MAKE FIRM GROUND TO CONDUIT SYSTEM. GROUND CONDUCTORS AS INDICATED ON THE PRIOR TO EXECUTION OF WORK.
DRAWINGS MUST BE CONTINUOUS FROM ORIGIN TO TERMINATION AND PROPERLY BONDED
WITH LUGS AT BOTH ENDS. 28: NEUTRAL POINT AND TRANSFORMER HOUSING SHALL ALWAYS BE earth.
29: ALL OUTDOOR EQUIPMENT TO SUIT 50 DEG. C. AS AMBIENT TEMPERATURE.
10: ALL MATERIALS TO BE USED SHALL BE NEW AND OF THE APPROVED TYPE FOR THE
LOCATION AND PURPOSE.
30: CONFIRM FRAME SIZES OF ALL BREAKERS WITH RESPECT TO CABLE SIZES.
11: STANDARD TYPES OF ACCESSORIES, SPLICING DEVICES, TERMINATION AND OTHER
APPARATUS FOR THE ENTIRE ELECTRICAL INSTALLATIONS SHALL BE USED.
31: CONTRACTOR TO CHECK SHORT CIRCUIT LEVEL AT ALL SWITCH/PANELBOARD PRIOR TO
ORDERING OF THE ABOVE.
12: LIGHT SWITCHES SHALL BE MOUNTED 1.20 M. FROM FINISHED FLOOR LEVEL UNLESS
OTHERWISE INDICATED. 32: CHECK LIGHT FIXTURE TYPE AGAINST CEILING OF EACH AREA AT SITE PRIOR TO
ORDERING OF FIXTURE.
13: POWER SOCKETS SHALL BE MOUNTED 0.4 M. FROM FINISHED FLOOR LEVEL UNLESS
OTHERWISE INDICATED.
33: CO-ORDINATE LOCATIONS OF ALL PANTRY EQUIPMENT AT SITE AND THEIR RATINGS TO
MATCH ELECTRICAL WORKS.
14: ALL CONDUITS AND WIREWAYS LOCATED AND/OR INDICATED ARE DIAGRAMATIC; EXACT
LOCATIONS IN ROOMS, WALL PENETRATIONS, ETC., SHALL BE DETERMINED BY THE
ENGINEER AT THE JOB SITE. 34: ALL STRUCTURES NEED TO BE EARTHED AS PER IEE.
15: ALL CONDUITS PASSING FROM ROOM TO ROOM SHALL BE PROVIDED WITH SLEEVES AND 35: CHECK FURNITURE LAYOUT PRIOR TO ROUGH-IN WORKS.
SEALED TO PREVENT PASSAGE OF AIR/MOISTURE.
36: WHILE WIRING OF FIXTURES, ALL WIRES SHALL BE SPLICED AT FIXTURES.
16: PROVIDE 20 MM DIAMETER EMPTY CONDUIT STUB-UP WITH CAPS INSIDE CEILING FROM
ALL FLUSH MOUNTED PANELBOARDS CORRESPONDING TO THE NUMBER OF SPARE 15/20 37: THE ENTIRE 11KV/415V POWER NETWORK SHOULD BE INSPECTED BY CONTRACTOR WITH
ENGINEER'S WRITTEN APPROVAL WHEN TESTED & COMMISSIONED BY MANUFACTURER'S
AMPERE BRANCH CIRCUIT.
REPRESENTATIVE.
17: THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSULT AND COORDINATE POWER 38: ALL SWITCHGEAR, 11 KV AND 415V, SHALL BE COMPLETELY VERMIN PROOF AND SHALL
SERVICE REQUIREMENTS OF THE PROJECT. BE PROVIDED WITH BOTTOM COVER PLATES.
18: ALL FLUORESCENT LIGHTING FIXTURES SHALL BE PROVIDED WITH HIGH POWER FACTOR, 39: VERIFY SUFFICIENT SPACE AVAILABILITY IN SHAFTS/CHASES FOR LOW VOLTAGE BUS
THERMAL PROTECTOR AND ELECTRONIC BALLAST OF THE CORRECT RATING, DUCTS/CABLES & LOW CURRENT CABLES.
CORRESPONDING TO THE NUMBER OF FLUORESCENT LAMPS ATTACHED TO THE FIXTURE
HOUSING, UNLESS OTHERWISE NOTED.

FR
LU
EN
X EL
BT
I
LO
EO
CU
OT
NL
DT
UB
I
TO
E

X
A
T
AC
SE
SI
MI
BG
L
Y
CO NDUIT RUN ON

N
SO FFIT
CO NDUIT

F
A
L
S
E
C
E
I
L
I
N
G
FIRE ALARM SADDLE
HO RN/ STANDARD CO NDUIT

S
U
P
P
O
R
T
FLAS HER BOX
EXPANSIO N ANCHO R
CO NDUIT RUN ON SO FFIT TO
BOLT
O THER STRUCTURAL
LUMINARIES AND DISTRIBUTIO N
4MM DIAMETER THREADED SUSPENDED BOARD SLAB
ROD LUMINAIRE FIXED TO
CO NDUIT SADDLE SECURED RO D PLUG-IN TYPE CEILING SLAB

A
D
J
U
S
T
A
B
L
E
B
A
R
H
A
N
G
E
R
BY ROSE
SO FFIT WITH SCREWS AND
PROPRIETARY 3 CO RE CIRCULAR FLEXIBLE PVC INSULATED
FIXING CABLE EXPANSIO N
230

S
C
R
E
W
E
D
T
O
H
A
N
G
E
R
PLUG IN CEILING INSERTS
CM
ROSE SCREW ED SUSPENSIO N REFER NO TE
RODS 2
SW ITCHES HEAT RESISTANT 3-CORE PVC CO NDUIT
CABLE GLAND W ITH
INSULATED PVC LO CKNUT
200 STANDARD CO NDUIT
CABLE
CM BOX
SUSPENDED CO NDUIT EXTENSIO N
CO NDUIT TO NEXT LUMINAIRE CEILING RING
SET PANEL OR
BOARD DISTRIBUTIO N LUMINAIRE
TUB TO THIS BOARD
CO URSE SINGLE CO RE PVC INSULATED C ABLE W ITH HEAT
LINE PANEL RESISTANT SLEEVES TO TERMINAL
BOARD BLO CK
4MM SQ . CIRCUIT PRO TECTIVE
CO NDUCTOR
FRO M LUMINAIRE BO DY TO C EILING CO NDUIT INDEPENDENTLY
125 FIRE ALARM
SUSPENSIO N SUPPO RTED
CM STATIO N SUSPENDED CEILING (REFER
BY S CREWED DRO P RO D FIXED
NOTE-3) CO NDUIT TO
RECESSED BUSH & SO FFIT
LUMINAIRE SO CKET ABO VE
LIGHT STANDARD CO NDUIT
110 STANDARD CO NDUIT BO X SW ITCH BOX
CM IMMEDIATELY
ADJACENT EXTENSIO N
LUMINAIRE RING

F
I
X
T
U
R
E
O
U
T
L
E
T
B
O
X
SINGLE
SO CKET
CO NDUIT REV. DATE DESCRIPTION BY CHECKED

A
S
S
E
M
B
L
Y
F
L
U
S
H
M
O
U
N
T
E
D
DOUBLE BUSH &
SO CKET SO CKET
PO WER LIGHT
O UTLET SW ITCH
TELEPHO NE
O UTLET REVISION

FC
AE
LI
SL
EI
40 LUMINAIRE
TELEVISIO N
CM SINGLE CORE PVC

N
G
O UTLET
CABLES
PASS THRO UGH HO LE
W ITH
GROMMET IN
LUMINAIRE
ENCLOSURE SO LID CEILING
FFL
HEAT RESISTANT CEILING RO SE
SLEEVING
O VER SINGLE CORE PVC INSULATED
CABLES 3 CO RE
FLEXIBLE CABLE
MOUNT EQUIPMENT AS SHOW N UNLESS O THERW ISE
SPECIFIED FIXED TERMINAL LAMP
NOT ALL EQUIPMENT SH OW N IS USED IN THE BLO CK HO LDER
PRO JECT

CLIENT

RECESSED LUMINAIRE WITH NON-DEMOUNTABLE


RECESSED LUMINAIRE IN NON-DEMOUNTABLE SUSPENDED CEILING SURFACE MOUNTED LUMINAIRE
1 EQUIPMENT MOUNTING HEIGHT ELEVATION 2 CEILING AND SWITCH IN UN-INSTALLED WALL
4 INSTALLATION 5 BOX SUPPORT INSTALLATION GOVERNMENT OF SOMALILAND
SCALE N.T.S. SCALE N.T.S.
3 SCALE N.T.S. SCALE N.T.S.
SCALE N.T.S.
L
O
C
K
N
U
T
&

C
E
I
L
I
N
G
B
U
S
H
I
N
G
C
O
N
N
E
C
T
O
R

PLOT NO BLOCK NO. TOW N


V
E
N
T

OB
UO
TX
L
E
T

CONDUIT THROUGH BOX


30CM
H
O
U
S
I
N
G
H
O
L
E
S

C
E
I
L
I
N
G
S
L
A
B
F
L
E
X
I
B
L
E
A
D
J
U
S
T
A
B
L
E

RECESSED CONDUIT
C
O
N
D
U
I
T
SC
TO
RN
AN
I
GE
HC
TT
MB
OR
UA
NK
TE
I
NT
G

C
E
I
L
I
N

TO DISTRIBUTION BOARD ---- -- HARGEISA


C

O
R

S O C
L U OF
A
B T

M
A
S
O
N
R
Y
A
N
C
H
O
R
EXIT
CMW
OAA
NSL
COL
RN
EA
TR
EY

L NE
E EX
T CI
B T
O R
X
JB
UO
NX
C
T
I
O
N
M
U
L
T
I
-
G
R
O
O
V
E

E
.
M
.
T
.
SUSPENDED CEILING
F
A
L
S
E

NL

OL
B
A
F
F
L
E

C
E
I
L
I
N
G

B
E
C
O
N
D
U
I
T

PENDANT MOUNTED EXIT LIGHT

C
O
N
D
U
I
T
C
L
A
M
P
8A
C
O
N
N
E
C
T
O
R
F
I
X
T
U
R
E

L
O
C
K
N
U
T
&
B
U
S
H
I
N
G
SCALE N.T.S.
PROJECT TITLE
S
U
S
P
E
N
D
E
D
C
E
I
L
I
N
G
DRT
EE
I
CV
AE
SR
TS

SWITCH OUT SIDE WALL MOUNTED


I
B
L
E

OF WATER HEATER
R
I
M

TOUELLET
F
R
A
M
E

F
I
N
I
S
H

C
E
I
L
I
N
G

WAAHEEN SHOPPING MARKET


F
L
O
O
R

3 CORE HEAT RESISTANT

FLEXIBLE CABLE

EXIT DRAWING TITLE

1350
DOUBLE POLE SWITCH

WITH FLEX OUTLET IN


RECESSED MOUNTING BOX
FFL

GENERAL ELECTRICAL NOTES & DETAILS 1

6 ROUND DOWNLIGHT FIXTURE RECESS MOUNTED 7 FIXTURE INSTALLATION - (FALSE CEILING) 8B CEILING MOUNTED EXIT LIGHT 9 SURFACE MOUNTED IONIZATION DETECTOR 10 WATER HEATER WITH LOCAL SWITCH
PROJECT NO. DRAWING NO. SHEET NO
SCALE N.T.S. SCALE N.T.S. SCALE N.T.S. SCALE N.T.S. SCALE N.T.S.

059-0719 E-00 1 OF 1

SCALE REVISION NO. DATE

As
indicated 02 DEC.2022

You might also like