FW Pump Calpeda2
FW Pump Calpeda2
NG Self-Priming Pumps
Construction
Close-coupled self-priming shallow well jet pumps with
built-in ejector.
NG: version with pump casing and lanter bracket in cast iron.
B-NG: version with pump casing and lanter bracket in bronze
(the pumps are supplied fully painted).
Applications
For drawing water out of a well.
As pressure boosting pump for central water systems with
low pressure (follow local specifications if increasing network
pressure).
For clean liquids or slightly dirty surface water.
For garden use.
For washing with a jet of water.
Operating conditions
Liquid temperature up to 40 °C.
Ambient temperature up to 40 °C.
Maximum permissible working pressure up to 10 bar.
Continuous duty (S3 60% for 1,5 kW).
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
NG: three-phase 230/400 V ± 10%.
NGM:single-phase 230 V ± 10%, with thermal protector.
Materials Capacitor inside the terminal box.
Components NG B-NG Insulation class F.
Pump casing Protection IP 54.
Cover with lantern bracket Cast iron Bronze
Diffuser plate GJL 200 EN 1561 CC480K EN 1982 IE2 efficiency class for single-phase motors up to 1,1 kW.
IE3 efficiency class for three-phase motors (IE2 up to 0,65 kW).
Impeller Brass CW617N EN 12165
Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Shaft Cr steel 1.4104 EN 10088 Cr-Ni-Mo steel EN 60335-1, EN 60335-2-41.
(AISI 430) for NG 3-4 1.4401 EN 10088
Cr-Ni steel 1.4305 EN 10088 AISI 316
(AISI 303) for NG 5-6-7 Special features on request
Diffuser PPO-GF20 (Noryl)
- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Nozzle PPO-GF20 (Noryl) - Protection IP 55.
Mechanical seal Carbon - Ceramic - NBR - Special mechanical seal
80
60 200 50
H
m ft H H 150
m ft m ft
60 200 50 NG 7/18 40 NG 7/22
NG 7/16
150
50 NG 6/22 100
40 NG 6/18 30
229
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 230
NG Self-Priming Pumps
P1 Max. power input. P2 Rated motor power output. B-NG, B-NGM = Bronze construction. Tolerances according to UNI EN ISO 9906:2012
230
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 231
NG Self-Priming Pumps
NG 3 180 NG 4 140
40 130
50 Ø 130
160
Ø 130
120
35
140
110
Hm
Hm
H ft
H ft
40
120 30 100
90
30 100
25
80
80
70
20 20
0 3
Q m /h 0.5 1 1.5 2 2.5 3 0 3 1 2 3 4
Q m /h
0 l/min 10 20 30 40 50 0 l/min 10 20 30 40 50 60 70
0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 l/s 0.2 0.4 0.6 0.8 1
0.7 0.7
0.9
0.9
0.6 0.8
P kW
P kW
P HP
P HP
0.6
0.8
0.7
0.5
0.6
0.7
0.4 0.5
8 25
NPSH m
NPSH m
6 20 20
NPSH ft
NPSH ft
15 5
4
10 10
2
5
0 72.163
0 0 72.164
0
0 Q m3/h 0.5 1 1.5 2 2.5 3 0 Q m3/h 1 2 3 4
231
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 232
NG Self-Priming Pumps
200
60 50
160
Ø 143 Ø 143
180
140
Hm
Hm
H ft
H ft
50 40
160
120
140
40 30 100
120
80
30 100 20
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4 5 6
0 l/min 20 30 40 50 60 70 0 l/min 20 40 60 80 100
0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
1.2
1.2 1.6
P kW
P kW
P HP
P HP
1.6
1.1 1.5
1.4
1.1 1.5 1.0
8 25 8 25
NPSH m
NPSH m
NPSH ft
NPSH ft
6 20 6 20
15 15
4 4
10 10
2 5 2 5
0 72.168
0 0 72.169
0
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4 5 6
0 U.S. g.p.m. 10 20 30 40
40
120
NG 5/22
Ø 134
30 100
Hm
H ft
80
20
60
40
10
0 3 2 4 6 8 10
Q m /h
0 l/min 50 100 150
1.1 1.5
P kW
P HP
1.4
1.0
1.3
0.9
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 72.170
0
0 Q m3/h 2 4 6 8 10
232
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 233
NG Self-Priming Pumps
NG 6/18 200
60 50
Ø 157 160
NG 6/22
180 Ø 157
NGM 6/18 140
Hm
Hm
Ø 149
H ft
H ft
50 40 NGM 6/22
160
Ø 149
120
140
40 30 100
120
80
30 100 20
0 m3/h 1 2 3 4 5 6 0 Q m3/h 2 4 6 8 10
Q
0 l/min 20 30 40 50 60 70 80 90 100 0 l/min 40 60 80 100 120 140 160
0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 0 l/s 0.4 0.8 1.2 1.6 2 2.4
1.8 2.0
NG 6/18 2.4 2.6
1.7 NG 6/22
1.8 2.4
2.2
P kW
P kW
1.6
P HP
P HP
1.6 2.2
1.5 NGM 6/18 NGM 6/22
2.0 2.0
1.4 1.4
1.8
1.3 1.8
1.2 1.6
8 25
8 25
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
6 20
15 15
4 4
10 10
2 2
5 5
0 72.171
0 0 72.172
0
0 Q m /h
3 1 2 3 4 5 6 0 Q m /h
3 2 4 6 8 10
233
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 234
NG Self-Priming Pumps
Hm
250 200
H ft
H ft
60
70 230
180
210
50
60 160
190
140
170
50 40
0 3 1 2 3 4 5 0
Q m /h 1
3 2 3 4 5 6 7
Q m /h
0 l/min 20 30 40 50 60 70 80 0 l/min 20 40 60 80 100
0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
2.3 2.2
3.0 2.9
2.1
2.1 2.8
P kW
P kW
2.8
P HP
P HP
2.0 2.7
1.9 2.6
1.9 2.6
2.4 2.5
1.7 1.8
10 10
30 30
NPSH m
NPSH m
8 8
NPSH ft
NPSH ft
6 20 6 20
4 4
10 10
2 2
0 72.178
0 0 72.173
0
0 Q m3/h 1 2 3 4 5 0 Q m3/h 1 2 3 4 5 6 7
0 U.S. g.p.m. 10 20 30 40
70
220
NG 7/22
200
60
Ø 164
180
Hm
H ft
50
160
140
40
120
30 100
3
0 Q m /h 2 4 6 8 10
0 l/min 40 60 80 100 120 140 160
P HP
1.9 2.6
1.8
2.4
1.7
1.6 2.2
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 72.174
0
0 Q m3/h 2 4 6 8 10
234
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 235
NG Self-Priming Pumps
fM
a2 a1
DN2
h2
DN1
h1
g
4.93.104
m2 m3 s b
m1 n2
w w1 n1
mm kg
DN1 DN2
TYPE
TIPO
ISO 228 a1 a2 fM h1 h2 H m1 m2 m3 n1 n2 b s w w1 g NG B-NG
Installation examples
≥1m
Check valve.
3.93.100.1
4.93.100
Check valve.
235
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 236
NG Self-Priming Pumps
Features
3.94.116
Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid
are dimensioned to guarantee the maximum resistence to mechanical stress.
Self priming
The hydraulic design allows the pump to self prime even with the high suction
lifts or with long suction pipe runs above the water level.
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NG series pumps to be selected
for use with different types of liquids.
236