223_276_ING2023.

qxp_145_160_ING 17/10/23 11:29 Pagina 229

NG Self-Priming Pumps

Construction
Close-coupled self-priming shallow well jet pumps with
built-in ejector.
NG: version with pump casing and lanter bracket in cast iron.
B-NG: version with pump casing and lanter bracket in bronze
(the pumps are supplied fully painted).

Applications
For drawing water out of a well.
As pressure boosting pump for central water systems with
low pressure (follow local specifications if increasing network
pressure).
For clean liquids or slightly dirty surface water.
For garden use.
For washing with a jet of water.

Operating conditions
Liquid temperature up to 40 °C.
Ambient temperature up to 40 °C.
Maximum permissible working pressure up to 10 bar.
Continuous duty (S3 60% for 1,5 kW).

Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
NG: three-phase 230/400 V ± 10%.
NGM:single-phase 230 V ± 10%, with thermal protector.
Materials Capacitor inside the terminal box.
Components NG B-NG Insulation class F.
Pump casing Protection IP 54.
Cover with lantern bracket Cast iron Bronze
Diffuser plate GJL 200 EN 1561 CC480K EN 1982 IE2 efficiency class for single-phase motors up to 1,1 kW.
IE3 efficiency class for three-phase motors (IE2 up to 0,65 kW).
Impeller Brass CW617N EN 12165
Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Shaft Cr steel 1.4104 EN 10088 Cr-Ni-Mo steel EN 60335-1, EN 60335-2-41.
(AISI 430) for NG 3-4 1.4401 EN 10088
Cr-Ni steel 1.4305 EN 10088 AISI 316
(AISI 303) for NG 5-6-7 Special features on request
Diffuser PPO-GF20 (Noryl)
- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Nozzle PPO-GF20 (Noryl) - Protection IP 55.
Mechanical seal Carbon - Ceramic - NBR - Special mechanical seal

Characteristic curves for suction lift Hs = 1 m n ≈ 2900 rpm


0 Imp. g.p.m. 10 15 0 Imp. g.p.m. 10 20 0 Imp. g.p.m. 20 30

0 U.S. g.p.m. 10 15 20 0 U.S. g.p.m.10 20 30 0 U.S. g.p.m. 20 30 40


100 80 70
250
90 300
70 60 200

80

60 200 50
H
m ft H H 150
m ft m ft
60 200 50 NG 7/18 40 NG 7/22
NG 7/16
150
50 NG 6/22 100
40 NG 6/18 30

40 NGM 6/18 NGM 6/22


NG 5/16
30 100 20
30 100
NG 5/18 50
NG 4 NG 5/22
NG 3
20 20 10
0 m3 /h 2 3 4 5 0 m3 /h 2 3 4 5 6 7 0 m3 /h 4 6 8 10
0 Q l/min 40 60 80 0 Q l/min 50 100 0 Q l/min 50 100 150
72 861

229
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 230

NG Self-Priming Pumps

Performance for suction lift Hs = 1 m n ≈ 2900 rpm


Q
3~ 230V 400V 1~ 230V P1 P2 m3/h 0,25 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 8 9 9,5
A A A kW kW HP l/min 4,1 8,3 16,6 25 33,3 41,6 50 58,3 66,6 75 83,3 91,6 100 108 116 133 150 158
B- NG 3/A 3 1,7 B- NGM 3/A 4,5 0,9 0,55 0,75 49 45,5 40 36 32 28 24
B- NG 4/B 3,7 2,2 B- NGM 4/A 5,7 1 0,75 1 41 39 36 33 31 29 26 24 21
B- NG 5/16/A 4,7 2,7 B- NGM 5/16E 7,4 1,64 1,1 1,5 59 54 50 46 43 40 37 34,5 32
B- NG 5/18/A 4,7 2,7 B- NGM 5/18E 7,4 1,68 1,1 1,5 48,5 46 43,5 41,5 39,5 38 35,5 34 32 30,5 29 28
B- NG 5/22/A 4,7 2,7 B- NGM 5/22E 7,4 1,55 1,1 1,5 35,5 34,5 33 31,5 30,5 29,5 28 27 26 25 23,5 23 21,5 20,5 18,5 16,5 15,5
B- NG 6/18/A 7,5 4,3 1,5 2 64,5 62 59 56 54 51 48,5 46 43,5 41,5 39 36,5
H
B- NGM 6/18E 9,2 2 1,5 2 59 57 54 51 48 45 43 40 37,5 35 33 30
m
B- NG 6/22/A 7,5 4,3 1,5 2 51,5 50 48,5 47 46 44,5 43 41,5 40 39 37,5 36,5 35 33,5 31 28,5 27
B- NGM 6/22E 9,2 2 1,5 2 47 45 43,5 42 41 40 38 37 36 35 33 32 31 30 27 24 23
B- NG 7/16/B 9,15 5,3 2,2 3 89 83 77 72 67 62 58 54
B- NG 7/18/B 9,15 5,3 2,2 3 74,5 71,5 68,5 65,5 63 60 57,5 55 53 51 49 47 45
B- NG 7/22/B 9,15 5,3 2,2 3 59 57,5 56,5 55 54 52,5 51 50 48,5 47 45,5 44 42,5 41,5 38 35 34

P1 Max. power input. P2 Rated motor power output. B-NG, B-NGM = Bronze construction. Tolerances according to UNI EN ISO 9906:2012

230
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 231

NG Self-Priming Pumps

Characteristic curves n ≈ 2900 rpm


0 U.S. g.p.m. 4 6 8 10 12 14 0 U.S. g.p.m. 4 6 8 10 12 14 16 18
60 45

NG 3 180 NG 4 140

40 130
50 Ø 130
160
Ø 130
120
35
140
110
Hm

Hm
H ft

H ft
40
120 30 100

90
30 100
25
80
80
70
20 20
0 3
Q m /h 0.5 1 1.5 2 2.5 3 0 3 1 2 3 4
Q m /h
0 l/min 10 20 30 40 50 0 l/min 10 20 30 40 50 60 70

0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 l/s 0.2 0.4 0.6 0.8 1
0.7 0.7
0.9
0.9
0.6 0.8
P kW

P kW
P HP

P HP
0.6
0.8
0.7
0.5

0.6
0.7
0.4 0.5

8 25
NPSH m

NPSH m

6 20 20
NPSH ft

NPSH ft
15 5
4
10 10
2
5
0 72.163
0 0 72.164
0
0 Q m3/h 0.5 1 1.5 2 2.5 3 0 Q m3/h 1 2 3 4

231
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 232

NG Self-Priming Pumps

Characteristic curves n ≈ 2900 rpm


0 U.S. g.p.m. 5 10 15 20 0 U.S. g.p.m. 10 20 28
70 60
220
NG 5/16 NG 5/18 180

200
60 50
160
Ø 143 Ø 143
180
140
Hm

Hm
H ft

H ft
50 40
160
120

140
40 30 100

120
80

30 100 20
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4 5 6
0 l/min 20 30 40 50 60 70 0 l/min 20 40 60 80 100

0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6

1.2
1.2 1.6
P kW

P kW
P HP

P HP
1.6
1.1 1.5

1.4
1.1 1.5 1.0

8 25 8 25
NPSH m

NPSH m
NPSH ft

NPSH ft
6 20 6 20
15 15
4 4
10 10
2 5 2 5
0 72.168
0 0 72.169
0
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4 5 6

0 U.S. g.p.m. 10 20 30 40
40

120
NG 5/22
Ø 134

30 100
Hm

H ft

80

20
60

40
10
0 3 2 4 6 8 10
Q m /h
0 l/min 50 100 150

0 l/s 0.5 1 1.5 2 2.5


1.2
1.6

1.1 1.5
P kW

P HP

1.4
1.0
1.3
0.9

8 25
NPSH m

6 20
NPSH ft

15
4
10
2
5
0 72.170
0
0 Q m3/h 2 4 6 8 10

232
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 233

NG Self-Priming Pumps

Characteristic curves n ≈ 2900 rpm


0 U.S. g.p.m. 10 20 28 0 U.S. g.p.m. 10 20 30 40
70 60
220
NG 6/18 NG 6/22 180

NG 6/18 200
60 50
Ø 157 160
NG 6/22
180 Ø 157
NGM 6/18 140

Hm
Hm

Ø 149

H ft

H ft
50 40 NGM 6/22
160
Ø 149
120

140
40 30 100

120
80

30 100 20
0 m3/h 1 2 3 4 5 6 0 Q m3/h 2 4 6 8 10
Q
0 l/min 20 30 40 50 60 70 80 90 100 0 l/min 40 60 80 100 120 140 160
0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 0 l/s 0.4 0.8 1.2 1.6 2 2.4
1.8 2.0
NG 6/18 2.4 2.6
1.7 NG 6/22
1.8 2.4
2.2
P kW
P kW

1.6
P HP

P HP
1.6 2.2
1.5 NGM 6/18 NGM 6/22
2.0 2.0
1.4 1.4
1.8
1.3 1.8
1.2 1.6
8 25
8 25
NPSH m
NPSH m

6 20
NPSH ft

NPSH ft
6 20
15 15
4 4
10 10
2 2
5 5
0 72.171
0 0 72.172
0
0 Q m /h
3 1 2 3 4 5 6 0 Q m /h
3 2 4 6 8 10

233
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 234

NG Self-Priming Pumps

Characteristic curves n ≈ 2900 rpm


0 U.S. g.p.m. 5 10 15 20 0 U.S. g.p.m. 10 20 30
100 80 260
310 NG 7/18
240
90
Ø 164
NG 7/16 290 70 Ø 164
220
270
80
Hm

Hm
250 200

H ft

H ft
60

70 230
180
210
50
60 160
190
140
170
50 40
0 3 1 2 3 4 5 0
Q m /h 1
3 2 3 4 5 6 7
Q m /h
0 l/min 20 30 40 50 60 70 80 0 l/min 20 40 60 80 100

0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
2.3 2.2
3.0 2.9
2.1
2.1 2.8
P kW

P kW

2.8
P HP

P HP
2.0 2.7
1.9 2.6
1.9 2.6
2.4 2.5
1.7 1.8

10 10
30 30
NPSH m

NPSH m

8 8
NPSH ft

NPSH ft
6 20 6 20
4 4
10 10
2 2
0 72.178
0 0 72.173
0
0 Q m3/h 1 2 3 4 5 0 Q m3/h 1 2 3 4 5 6 7

0 U.S. g.p.m. 10 20 30 40
70
220
NG 7/22
200
60
Ø 164
180
Hm

H ft

50
160

140
40
120

30 100
3
0 Q m /h 2 4 6 8 10
0 l/min 40 60 80 100 120 140 160

0 l/s 0.4 0.8 1.2 1.6 2 2.4


2.2
2.1
2.8
2.0
P kW

P HP

1.9 2.6
1.8
2.4
1.7
1.6 2.2

8 25
NPSH m

6 20
NPSH ft

15
4
10
2
5
0 72.174
0
0 Q m3/h 2 4 6 8 10

234
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 235

NG Self-Priming Pumps

Dimensions and weights

fM
a2 a1
DN2

h2
DN1

h1
g
4.93.104

m2 m3 s b
m1 n2
w w1 n1

mm kg
DN1 DN2
TYPE
TIPO
ISO 228 a1 a2 fM h1 h2 H m1 m2 m3 n1 n2 b s w w1 g NG B-NG

NG 3/A B-NG 3 /A 18,4 20,8


G1 G1 127 8 430 150 43 207 60 52 8 185 155 35 9,5 100 - 11
NG 4/B B-NG 4/B 20,0 22,3
NG 5/A B-NG 5E 560 - 29,2 31,6
NG 6/A B-NG 6E G 11/2 G1 160 10 560 165 57 240 60 50 10 215 175 40 11,5 115 - 11 30,8 32,9
NG 7/B B-NG 7/A 600 233 31,3 33,4

Installation examples

Positive suction head operation Suction lift operation

≥1m
Check valve.

3.93.100.1
4.93.100

Check valve.

235
223_276_ING2023.qxp_145_160_ING 17/10/23 11:29 Pagina 236

NG Self-Priming Pumps

Features

3.94.116

Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid
are dimensioned to guarantee the maximum resistence to mechanical stress.

Self priming
The hydraulic design allows the pump to self prime even with the high suction
lifts or with long suction pipe runs above the water level.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NG series pumps to be selected
for use with different types of liquids.

236