Poweredge r710
Poweredge r710
POWEREDGE ™
R710
technical guidebook
Inside the poweredge R710
TABLE OF CONTENTS
Section 2. Mechanical 7
A. Chassis Description 7
B. Dimensions and Weight 8
C. Front Panel View and Features 8
D. Back Panel View and Features 8
E. Power Supply Indicators 9
F. NIC Indicators 9
G. Side Views and Features 9
H. Rails and Cable Management 10
I. Fans 10
J. Control Panel / LCD 11
K. Security 11
I. Cover Latch 11
II. Bezel 12
III. Hard Drive 12
IV. TPM 12
V. Power Off Security 12
VI. Intrusion Alert 12
VII. Secure Mode 12
L. USB Key 12
M. Battery 12
N. Field Replaceable Units (FRU) 12
Section 3. Electrical 13
A. Volatility 13
B. ePPID (Electronic Piece Part Identification) 13
Section 6. Processors 21
A. Overview / Description 21
B. Features 21
C. Supported Processors 21
D. Processor Configurations 22
Section 7. Memory 23
A. Overview / Description 23
B. DIMMs Supported 23
C. Speed 24
D. Slots / Risers 27
E. Supported Configurations 27
F. Mirroring 28
G. Advanced ECC (Lockstep) Modes 28
H. Optimizer (Independent Channel) Mode 28
Section 8. Chipset 29
A. Overview / Description 29
Section 9. BIOS 31
A. Overview / Description 31
B. Supported ACPI States 31
C. I2C (Inter-Integrated Circuit) 32
D. Storage Controllers 39
I. SAS 6/iR 39
II. PERC 6i 40
E. LED Indicators 41
F. Optical Drives 41
G. Tape Drives 41
appendix 54
Strong IT Foundation
As an IT professional, you want a data center built to allow for organic growth and the ability to scale
based on your company’s changing requirements. You need complete solutions that allow you to
focus your time and money on managing and growing your business. Dell understands your needs and
responds with an expanding portfolio of enterprise servers, storage technologies, and services with a
single goal: to help you simplify IT.
Purposeful Design
The R710 takes advantage of Dell’s system commonality. Once your IT managers learn one system, they
understand how to manage next-generation Dell servers. Logical component layout and power supply
placement also provide a straightforward installation and redeployment experience. Featuring 18 DIMM
slots and 4 integrated network connections, the R710 delivers the critical components to virtualization
and database performance. The Intel Xeon Processor 5500 Series adapts to your software in real time,
processing more tasks simultaneously. Using Intel® Turbo Boost Technology, the R710 can increase
performance during peak usage periods. You can then help reduce operating costs and energy usage
with Intel® Intelligent Power Technology, which proactively puts your server into lower power states when
demand decreases. Increased memory slots also save money by enabling you to use smaller,
less-expensive DIMMs to meet your computing needs.
Enhanced Virtualization
Featuring Intel Xeon-based architecture, embedded hypervisors, large memory capacity, and integrated
I/O, the next-generation Dell PowerEdge R710 delivers better overall system performance and greater
virtual machine-per-server capacity. With optional factory-integrated virtualization capabilities, you get
tailored solutions – built with the latest technologies from Dell and our trusted partners – which allow
you to streamline deployment and simplify virtual infrastructures. Choose your hypervisor from market
leaders such as VMware®, Citrix®, and Microsoft®, and enable virtualization with a few mouse clicks.
Energy-Optimized Technologies
Using the latest Energy Smart technologies, the R710 reduces power consumption while increasing
performance capacity versus the previous generation servers. Enhancements include efficient power
supply units right-sized for system requirements, improved system-level design efficiency, policy-driven
power and thermal management, and highly efficient standards-based Energy Smart components. Dell's
advanced thermal control delivers optimal performance at minimal system and fan power consumption
resulting in our quietest 2U servers to date. These enhancements maximize energy efficiency across our
latest core data center servers without compromising enterprise performance.
strategic technology usage. Secure, efficient, and more user friendly than its predecessors, the Dell
Unified Server Configurator (USC) delivers “Instant On” integrated manageability through a single
access point. You get quick, persistent access to the tool because it is embedded and integrated into
the system for increased flexibility and capabilities. The USC is a one-stop shop for deploying operating
systems with built-in driver installations, firmware updates, hardware configuration, and issue diagnoses.
A. Overview / Description
The PowerEdge R710 will lead Dell's 11th Generation PowerEdge portfolio in key areas of differentiation,
primarily:
• Virtualization
• Power, thermal, efficiency
• Systems management, and usability
Feature Details
Processor Nehalem EP
Front Side Bus Intel® QuickPath Interconnect (QPI) @ maximum 6.GT/s
# Procs 2S
# Cores 4 cores
L2/L3 Cache 4MB and 8MB
Chipset Tylersberg
DIMMs/Speed 18 RDIMM or UDIMM DDR3 (9 per processor)
Min/Max RAM 1GB – 144GB
Internal hard drive bay and hot-plug backplane
HD Bays Up to six 3.5" SAS or SATA drives without optional flex bay OR
Up to eight 2.5" SAS or SATA drives with optional flex bay
HD Types SAS, SATA, Near-line SAS, and SSD
Ext Drive Bay(s) Optional flex-bay expansion to support a half-height TBU
Int. HD Controller PERC 6i and SAS 6/iR
Opt. HD Controller
BIOS
Video Based on the Matrox G200 w/iDRAC
Availability
Server
Management
I/O Slots Two x8 and two x4 PCIe Gen2 slots or One x16 PCIe slot and two x4 PCIe Gen2
Feature Details
Front Control The system control panel is located on the front of the system chassis to provide
Panel user access to buttons, display, and I/O interfaces
System ID Front and rear (0x0235)
Five hot-swappable
Fans Additional fan integrated into each power supply
Single processor configurations will only have four fans
Chassis 2u Rackmount
Section 2. Mechanical
A. Chassis Description
PowerEdge R710 is a 2U rackmount chassis. The updated design includes a new LCD, bezel and
hard-drive carriers. Additional changes include tool-less rack latches, a pull out tray for customer labels,
and LOM0/iDRAC MAC address; labels; support persistent storage (internal USB and SD card slots and
external SD card slots); updated power supplies and removal process.
F. NIC Indicators
Link and activity indicators are off The NIC is not connected to the network
Link indicator is green The NIC is connected to a valid network link at 1000 Mbps
Link indicator is amber The NIC is connected to a valid network link at 1000 Mbps
Activity indicator is green blinking Network data is being sent or received
Rack installation components such as rails are provided with the PowerEdge R710 Rack Kit. The rack
installation components are as follows: Sliding rack mount with latest generation Cable Management
Arm (CMA). When the system is installed in a rack, please observe the following guideline:
hen the system is installed in a rack, only Dell-approved CMAs should be installed behind
W
the chassis.
Rails
• Enable the replacement of thumbscrews with slam latches on the chassis for easier stowing in
the rack.
• Include the new simple and intuitive ReadyRail™ tool-less rack interface for square-hole and
round-hole racks.
• Provide significantly improved compatibility with non-Dell racks.
• Static rails for the R610 & R710 fit in all types of four-post and two-post racks available in the
industry including four-post threaded hole racks.
CMAs
• Provide much larger vent pattern for improved airflow through the CMA.
• Include a common support tray for eliminating CMA sag.
• Replaced tie wraps with hook and loop straps to eliminate risk of cable damage during cycling.
• Maintain key feature of being fully reversible with no conversion required.
I. Fans
Fans
Five hot-swappable fans are mounted in a fan gantry that is located in the chassis between the hard
drive bay and the processors. Each fan has a blind mate 2x2 connector that plugs directly into the
planar. There is an additional fan integrated in each power supply to cool the power supply subsystem
and also provide additional cooling for the whole system. Single processor configurations will have four
fans populated.
The Embedded Server Management logic in the system monitors the speed of the fans. A fan failure
or over-temperature in the system results in a notification by iDRAC6. All system fans are pulse-width
modulated fans. Redundant cooling is supported with one fan failing at a time.
10
The system control panel is located on the front of the system chassis to provide user access to
switches, display, and I/O interfaces. Features of the system control panel are:
• ACPI-compliant power button with an integrated green power LED (controlled by ESM)
• 128x20 pixel LCD with controls
• Two navigation buttons
• One-select button
• One system ID button
• Non-Maskable-Interrupt (NMI) button (recessed)
• Ambient temperature sensor
• Two external USB 2.0 connectors (with two internal connectors dedicated for UIPS)
• 15-pin VGA connector
The LCD panel is a graphics display controlled by the BMC/ESM. Both ESM and BIOS can send error
codes and messages to the display.
The system’s LCD panel provides system information and status messages to signify when the system is
operating correctly or when the system needs attention.
The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error
condition. When the system is in standby mode, the LCD backlight is off and can be turned on by
pressing the Select button on the LCD panel. The LCD backlight will remain off if the “No Message"
option is selected through the iDRAC6, the LCD panel, or other tools.
BIOS has the ability to enter a “Secure Mode" through Setup, which locks the power and NMI buttons.
When in this mode, pressing either button has no effect but does not mask other sources of NMI and
power control.
K. Security
I. Cover Latch
A tooled entry latch is provided on the top of the unit to secure the top cover to the chassis
11
II. Bezel
A metal bezel is mounted to the chassis front to provide the Dell ID. A lock on the bezel is used to
protect un-authorized access to system peripherals and the control panel. System status via the LCD is
viewable even when the bezel is installed.
IV. TPM
The TPM is used to generate/store keys, protect/authenticate passwords, and create/store digital
certificates. TPM can also be used to enable the BitLocker™ hard drive encryption feature in Windows
Server® 2008. TPM is enabled through a BIOS option and uses HMAC-SHA1-160 for binding. There will be
different planar PWA part numbers to accommodate the different TPM solutions. The “Rest of World"
(ROW) version will have the TPM soldered onto the planar. The other version of the planar (post RTS
and primarily for use by China) will have a connector for a plug-in module.
L. USB Key
The port on the control panel is for an optional USB key and is located inside the chassis. Some of the
possible applications of the USB key are:
• User custom boot and pre-boot OS for ease of deployment or diskless environments
• USB license keys for software applications like eToken™ or Sentinel Hardware Keys
• Storage of custom logs or scratch pad for portable user defined information (not hot-swappable)
M. Battery
A replaceable coin cell CR2032 3V battery is mounted on the planar to provide backup power for the
Real-Time Clock and CMOS RAM on the ICH9 chip.
12
Section 3. Electrical
A. Volatility
See Appendix A of this Technical Guidebook
storage
COMPOnent description
location
BOARDS
Planar PWA,PLN,SV,DELL,R710 iDRAC FRU
2.5" x 8' Backplane PWA,BKPLN,SV,R710,2.5SASX8 SEP
3.5" x 6' Backplane PWA,BKPLN,SV,R710,3.5SASX6 SEP
3.5" x 4' Backplane PWA,BKPLN,SV,R710,3.5SASX4 SEP
iDRAC Enterprise PWA,RSR, SV, DELL,AMEA FRU
Power supplies
PWR SPLY,885W,RDNT,ASTEC PSU Microcontroller
870W PowerEdge™ PSU
PWR SPLY,885W,RDNT,DELTA PSU Microcontroller
PWR SPLY,598W,RDNT,ASTEC PSU Microcontroller
570W Energy Smart PSU
PWR SPLY,598W,RDNT,COLDWATT PSU Microcontroller
storage cards
PERC 6/i Integrated ASSY,CRD,PERC6I-INT,SAS,NOSLED FRU
PERC 6/E External PWA,CTL,PCIE,SAS,PERC6/E,ADPT FRU
SAS 6/iR Integrated PWA,CTL,SAS,SAS6/IR,INTG FRU
Note: The fans do not have any integrated NVRAM. The PPID tables are currently scanned into a database by the system integrator.
13
A. Power Efficiencies
One of the main features of the 11th generation of PowerEdge servers is enhanced power efficiency.
PowerEdge R710 achieves higher power efficiency by implementing the following features:
• User-selectable power cap (subsystems will throttle to maintain the specified power cap)
• Improved power budgeting
• Accurate inlet temperature
• PSU / VR efficiency improvements
• Switching regulators instead of linear regulators
• Closed loop thermal throttling
• Increased rear venting / 3D venting
• PWM fans with an increased number of fan zones and configuration-dependent fan speeds
• Use of DDR3 memory (lower voltage compared to DDR2, UDIMM support)
• CPU VR dynamic phase shedding
• Memory VR static phase shedding
• Random time interval for system start
• Allows an entire rack to power on without exceeding the available power
• BIOS Power/Performance options page
• Active Power Controller (BIOS-based CPU P-state manager)
• Ability to power down or throttle memory
• Ability to disable a CPU core
• Ability to turn off LOMs or PCIe lanes when not being used
• Option to run PCIe at Gen1 speeds instead of Gen2
B. Power Supplies
I. Main Power Supply
The base redundant system consists of two hot-plug 570W Energy Smart (energy efficient) power
supplies in a 1+1 configuration. An 870W high-output power supply is also available. The power supplies
connect directly to the planar.
There is a power cable to connect between the planar and the backplane. PowerEdge R710 power
supplies have embedded cooling fans.
Starting with the 11th generation of PowerEdge servers (R710, R610, T610, M610, and M710), the
power supplies no longer have a FRU EEPROM. FRU data is now stored in the memory of the PSU
Microcontroller. Additionally, the PSU Firmware can now be updated by the BMC over the PMBus.
Power is “soft-switched,” allowing power cycling via a switch on the front of the system enclosure, or
via software control (through server management functions). In a single power supply configuration,
the power supply is installed in the PS1 location and a blank module (metal cover) is installed in the
PS2 location for factory consistency. Electrically, the system can operate with a single power supply in
either bay.
14
15
D. Environmental Specifications
temperature
Half sine shock in all operational orientations of 31G +/- 5% with a pulse
Operating
duration of 2.6 ms +/-10%
Half sine shock on all six sides of 71G +/- 5% with a pulse duration of
Storage 2 ms +/-10%: Square wave shock on all six sides of 27G with velocity
change @ 235 in/sec or greater
Altitude
-16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the
Operating
maximum operating temperature is derated 1°F/550 ft.
Storage -16 to 10,600 m (-50 to 35,000 ft)
16
17
H. Acoustics
The acoustical design of the PowerEdge R710 reflects the following:
• Adherence to Dell’s high sound quality standards. Sound quality is different from sound power
level and sound pressure level in that it describes how humans respond to annoyances in sound,
like whistles, hums, etc. One of the sound quality metrics in the Dell specification is prominence
ratio of a tone, and this is listed in the table below.
• Office environment acoustics. Compare the values for LpA in the table below and note that
they are lower than ambient noise levels of typical office environments.
• Hardware configurations affect system noise levels. Dell’s advanced thermal control provides
for optimized cooling with varying hardware configurations. Most typical configurations will
perform as listed in the table below. However some less typical configurations and components
can result in higher noise levels. For example, a system configured with a PERC6/E card will be
~
approximately twice as loud ( 9 dBA higher) in 23+/-2° C ambient.
• Noise ramp and descent at Bootup. Fan speeds hence noise levels ramp during the boot
process in order to add a layer of protection for component cooling in the case that the system
were not to boot properly.
PowerEdge R710 (2.5" and 3.5" chassis) with RK385 fans (quantity below), 2x 870-W FU096 Power
Supplies, 2.40 GHz Quad-Core E5530 CPUs (quantity below), 7x 2-GB DIMMs, 1x DVD Drive, Perc 6i
card, and 4x Hard Disk Drives (type below)
Acoustical dependence on quantities of fans, CPUs, and Hard Disk Drive type is not strong. The values
below represent therefore the performance for redundant (5x fans and 2x CPUs) as well as the
nonredundant (4x fans and 1x CPU) configurations. They also represent performance for 2.5" 10k SAS
XK112 as well as 3.5" 7.2k SATA NW340 Hard Disk Drives.
_ 2° C ambient
Condition in 23 + LwA-UL, bels LpA, dBA Tones
Definitions
Standby: AC Power is connected to Power Supply Units but system is not turned on.
Idle: Reference ISO7779 (1999) definition 3.1.7; system is running in its OS but no other specific activity.
Active Hard Drives: An operating mode per ISO7779 (1999) definition 3.1.6; Section C.9 of ECMA-74
9th ed. (2005) is followed in exercising the hard disk drives.
Stressed Processor: An operating mode per ISO7779 (1999) definition 3.1.6; SPECPower set to 50%
loading is used.
LwA-UL: The upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988) and
measured in accordance with ISO7779 (1999).
LpA: The average bystander position A-weighted sound pressure level calculated per section 4.3 of
ISO9296 (1988) and measured in accordance with ISO7779 (1999). The system is placed in a
rack with its bottom at 25-cm from the floor.
Tones: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if discrete tones are
prominent. The system is placed in a rack with its bottom at 75-cm from the floor. The acoustic
transducer is at front bystander position, ref ISO7779 (1999), Section 8.6.2.
18
19
1 2 3 4 5
8 8
11
10
20
Section 6. Processors
A. Overview / Description
The Intel 5500 series 2S processor (Nehalem - Efficient Processor (EP)), is the microprocessor designed
specifically for servers and workstation applications. The processor features quad-core processing to
maximize performance and performance/watt for data center infrastructures and highly dense
deployments. The Nehalem-EP 2S processor also features Intel’s Core™ micro-architecture and Intel
64 architecture for flexibility in 64-bit and 32-bit applications and operating systems.
The 5500 series 2S processor (Nehalem EP) utilizes a 1366-contact Flip-Chip Land Grid Array (FC-LGA)
package that plugs into a surface mount socket. PowerEdge R710 provides support for up to two 5500
series 2S processors (Nehalem EP).
B. Features
Key features of the 5500 series 2S processor (Nehalem EP) include:
• Four or two cores per processor
• Two point-to-point QuickPath Interconnect links at up to 6.4 GT/s
• 1366-pin FC-LGA package
• 45 nm process technology
• No termination required for non-populated CPUs (must populate CPU socket 1 first)
• Integrated three-channel DDR3 memory controller at up to 1333MHz
• Compatible with existing x86 code base
• MMX™ support
• Execute Disable Bit Intel Wide Dynamic Execution
• Executes up to four instructions per clock cycle
• Simultaneous Multi-Threading (Hyper-Threading) capability
• Support for CPU Turbo Mode (on certain SKUs)
• Increases CPU frequency if operating below thermal, power, and current limits
• Streaming SIMD (Single Instruction, Multiple Data) Extensions 2, 3, and 4
• Intel 64 Tecnology for Virtualization
• Intel VT-x and VT-d Technology for Virtualization
• Demand-based switching for active CPU power management as well as support for ACPI
P-States, C-States, and T-States
C. Supported Processors
21
D. Processor Configurations
Single CPU Configuration
The PowerEdge R710 is designed such that a single processor placed in the CPU1 socket will function
normally, however PowerEdge R710 systems require a CPU blank in the CPU2 socket for thermal reasons.
The system will be held in reset if a single processor is placed in the CPU2 socket.
TURBO Freq
Intel® Turbo Boost Intel® Hyper-Threading Cores / Threads BASE Freq Benefit
Technology Technology
Increases performance by increasing processor Increases performance for threading applications Core Core
Core 0Core 1
3.20 GHz up to 6%†
frequency and enabling faster speeds when delivering greater throughput and responsiveness
16
0 1
Core Core
conditions allow Core 2Core 3
for 16 concurrent
2 3 (2 socket/HT on) 2.93 GHz software threads
Normal 4C Turbo <4C Turbo
OR
Core 0
Core 0
Core 2
Core 3
Core 2
Core 3
Core 1
Core 1
Core 1
Core 1
Frequency
up to 10%
Core IDLE
Core 0IDLE 3.33 GHz
0
IDLE IDLE
IDLE IDLE
2 for 2 software
All cores All cores Fewer cores (2 socket/HT on) 2.93 GHz threads
operate operate may operate
at rated at higher at even higher
frequency frequency frequencies
Higher performance Higher performance Improves application responsiveness
on demand for threaded workloads Delivers higher processor frequency on demand
22
Section 7. Memory
A. Overview / Description
The PowerEdge R710 utilizes DDR3 memory providing a high performance, high-speed memory
interface capable of low latency response and high throughput. The PE R710 supports Registered
ECC DDR3 DIMMs (RDIMM) or Unbuffered ECC DDR3 DIMMs (UDIMM).
B. DIMMs Supported
The DDR3 memory interface consists of three channels, with up to two RDIMMs or UDIMMs per
channel for single-/dual-rank and up to two RDIMMs per channel for quad rank. The interface uses 2GB,
4GB, or 8GB RDIMMs. 1GB or 2GB UDIMMs are also supported. The memory mode is dependent on how
the memory is populated in the system:
23
The PowerEdge R710 memory interface supports memory demand and patrol scrubbing, single-bit
correction and multi-bit error detection. Correction of a x4 or x8 device failure is also possible with
SDDC in the Advanced ECC mode. Additionally, correction of a x4 device failure is possible in the Memory
Optimized mode. If DIMMs of different speeds are mixed, all channels will operate at the fastest common
frequency. RDIMMs and UDIMMs cannot be mixed.
• If memory mirroring is enabled, identical DIMMs must be installed in the same slots across both
channels.
• The third channel of each processor is unavailable for memory mirroring.
• The first DIMM slot in each channel is color-coded with white ejection tabs for ease of
installation.
• The DIMM sockets are placed 450 mils (11.43 mm) apart, center-to-center in order to provide
enough space for sufficient airflow to cool stacked DIMMs.
• The PE R710 memory system supports up to 18 DIMMs. DIMMs must be installed in each channel
starting with the DIMM farthest from the processor. Population order will be identified by the
silkscreen designator and the System Information Label (SIL) located on the chassis cover.
• Memory Optimized: {1, 2, 3}, {4, 5, 6}, {7, 8, 9}
• Advanced ECC or Mirrored: {2, 3}, {5, 6}, {8, 9}
• Quad Rank or UDIMM: {1, 2, 3}, {4, 5, 6}, {7, 8, 9}
C. Speed
Memory Speed Limitations
The memory frequency is determined by a variety of inputs:
• Speed of the DIMMs
• Speed supported by the CPU
• Configuration of the DIMMs
24
The table below shows the memory populations and the maximum frequency achievable for that
configuration.
SR 1
DR 1
UDIMM SR SR 2
SR DR 2
DR DR 2
SR 1
DR 1
QR 1
SR SR 2
SR DR 2
DR DR 2
RDIMM QR SR 2
QR DR 2
QR QR 2
SR SR SR 3
SR SR DR 3
SR DR DR 3
DR DR DR 3
Note: For QR mixed with an SR/DR DIMM, the QR needs to be in the white DIMM connector. There is no requirement in the order of SR and DR DIMMs.
Supported
Not Supported
NOTE: For Quad Rank DIMMs mixed with Single- or Dual-Rank DIMMs, the QR DIMM needs to be in the slot with the white ejection tabs (the first DIMM slot in each channel).
There is no requirement for the order of SR and DR DIMMs
25
Channel Channel
2 unused 2 unused
26
D. Slots / Risers
The PowerEdge R710 has 18 DIMM slots for memory. It does not have any riser cards for DIMM population.
E. Supported Configurations
x 2 4
x x 4 8
x x x x 6 12
2GB All All
x x 4 8
x x x x 8 16
x x x x x x 12 24
x 4 8
OPTIMIZER
x x 8 16
x x x x 12 24
4GB All All
x x 8 16
x x x x 16 32
x x x x x x 24 48
x 8 16
x x 16 32
x x x x 24 48
8GBa All All
x x 16 32
x x x x 32 64
x x x x x x 48 96
x x 4 2 8 4
2GB None
mirroring
Advanced
x x x x 8 4 16 8
ECCb or
x x 8 4 16 8
4GB None
x x x x 16 8 32 16
x x 16 8 32 16
8GB None
x x x x 32 16 64 32
Table: RDIMM Memory Configurations (Each Processor)
27
memory single
dual processor
UDIMM sockets processor
memory memory
mode module
size 1 2 3 physical available physical available
memory memory memory memory
4 5 6 (GB) (GB) (GB) (GB)
x 1 2
x x 2 4
1GB x x x 3 All 6 All
OPTIMIZER
x x x x 4 8
x x x x x x 6 12
x 2 4
x x 4 8
2GB x x x 6 All 12 All
x x x x 8 16
x x x x x x 12 24
None x x 2
Advanced
1GB
x x x x 4 2 8 4
None x x 4 2 8 4
2GB
x x x x 8 4 16 8
a
When available
b
Requires x4- or x8-based memory modules
F. Mirroring
The system supports memory mirroring if identical memory modules are installed in the two channels
closest to the processor (memory is not installed in the farthest channel). Mirroring must be enabled in
the System Setup program. In a mirrored configuration, the total available system memory is one-half of
the total installed physical memory.
28
Section 8. Chipset
A. Overview / Description
The PowerEdge R710 planar incorporated the Intel 5520 chipset (code named Tylersburg) for I/O and
processor interfacing. Tylersburg is designed to support Intel's 5500 series processors (code named
Nehalem-EP), QPI interconnect, DDR3 memory technology, and PCI Express Generation 2. The
Tylersburg chipset consists of the Tylersburg-36D IOH and ICH9.
The Intel 5520 chipset (code named Tylersburg) I/O Hub (IOH)
The planar uses the The Intel® 5520 chipset (code named Tylersburg) I/O Hub (IOH)-36D IOH to provide
a link between the 5500 series 2S processor (Nehalem EP) and I/O components. The main components
of the IOH consist of two full-width QuickPath Interconnect links (one to each processor), 36 lanes of
PCI Express Gen2, a x4 Direct Media Interface (DMI), and an integrated IOxAPIC.
The QuickPath Architecture implemented in the IOH and CPUs features four layers. The Physical layer
consists of the actual connection between components. It supports Polarity Inversion and Lane Reversal
for optimizing component placement and routing. The Link layer is responsible for flow control and the
reliable transmission of data. The Routing layer is responsible for the routing of QPI data packets. Finally,
the Protocol layer is responsible for high-level protocol communications, including the implementation of
a MESIF (Modify, Exclusive, Shared, Invalid, Forward) cache coherence protocol.
29
In the Tylersburg-36D IOH, there are two x2 PCIe Gen2 ports (1Gb/s) and eight x4 PCIe Gen2 ports (2
Gb/s). The x2 ports can be combined as a x4 link; however, this x4 link cannot be combined with any of
the other x4 ports. Two neighboring x4 ports can be combined as a x8 link, and both resulting x8 links
can combine to form a x16 link.
30
Section 9. BIOS
A. Overview / Description
The PowerEdge R710 BIOS is based on the Dell BIOS core, and supports the following features:
• Nehalem-EP 2S Support
• Simultaneous Multi-Threading (SMT) support
• CPU Turbo Mode support
• PCI 2.3 compliant
• Plug n’ Play 1.0a compliant
• MP (Multiprocessor) 1.4 compliant
• Boot from hard drive, optical drive, iSCSI drive, USB key, and SD card
• ACPI support
• Direct Media Interface (DMI) support
• PXE and WOL support for on-board NICs
• Memory mirroring and spare bank support
• SETUP access through <F2> key at end of POST
• USB 2.0 (USB boot code is 1.1 compliant)
• F1/F2 error logging in CMOS
• Virtual KVM, CD, and floppy support
• Unified Server Configurator (UEFI 2.1) support
• Power management support including DBS, power inventory and multiple power profiles
The Nehalem processor supports the following C-States: C0, C1, C1E, C3, and C6. R710 will support all of
the available C-States.
The PowerEdge R710 will support the available P-States as supported by the specific Nehalem processors:
proc standard
qdF # frequency lfm tdp p-state notes
number tdp
1.60 Pmin+0
1.73 Pmin+1
E5502 Q1G8 1.86 80 75 Pmin+2 D-0
E5504 Q1GM 2.00 80 75 Pmin+3 D-0
L5506 Q1HG 2.13 60 52 Pmin+4 D-0
E5506 Q1GL 2.13 80 75 Pmin+4 D-0
L5520 Q1GN 2.26 60 52 Pmin+5 D-0
E5520 Q1GR 2.26 80 75 Pmin+5 D-0
E5530 Q1GK 2.40 80 75 Pmin+6 D-0
31
proc standard
qdF # frequency lfm tdp p-state notes
number tdp
The PowerEdge R710, BIOS accesses the I2C through the ICH9 (Intel I/O Controller Hub 9). There are two
MUXes on ICH9’s I2C bus.
• One MUX (U_ICH_SPD) controls the DIMM SPDs through four split segments
• The other MUX (U_ICH_MAIN) controls the clock buffers, TOE, USB Hub through four split
segments.
BIOS controls both the MUXes through the two select lines using GPIO pins.
Clock chip, USB hub, and the front panel EEPROM device addresses are located on the IOH I2C bus.
A. Overview / Description
Embedded Gigabit Ethernet Controllers with TCP Offload Engine (TOE) support
Two embedded Broadcom 5709C dual-port LAN controllers are on the R710 planar as independent
Gigabit Ethernet interface devices. The following information details the features of the LAN devices.
• x4 PCI Express Gen2 capable interface
• The PowerEdge R710 operates this controller at Gen1 speed
• Integrated MAC and PHY 3072x18 Byte context memory
• 64 KB receive buffer
• TOE (TCP Offload Engine)
• iSCSI controller (enabled through an optional hardware key)
• RDMA controller (RNIC) (enabled post-RTS through an optional hardware key)
• NC-SI (Network Controller-Sideband Interface) connection for manageability
• Wake-On-LAN (WOL)
• PXE 2.0 remote boot
• iSCSI boot
• IPv4 and IPv6 support
• Bare metal deployment support
32
A. Overview / Description
The PowerEdge R710 requires two PCI Express risers: Riser 1 and Riser 2. Each riser connects to the
planar through an x16 PCI Express connector.
• Riser 1 consists of two x4 slots and a third x4 slot dedicated for internal SAS storage through
the PERC 6i or SAS 6/iR.
• The default Riser 2 consists of two x8 PCI Express connectors.
• There is also an optional x16 Riser 2 that supports one x16 PCI Express card.
To ensure proper cooling, no more than two of the four expansion cards can have a power consumption
of greater than 15W (up to 25W maximum each), not including the integrated storage controller.
The system does not support hot-plug or hot-removal of PCI Express cards.
The table below provides a guide for installing expansion cards to ensure proper cooling and mechanical
fit. The expansion cards with the highest priority should be installed first using the slot priority indicated.
All other expansion cards should be installed in card priority and slot priority order.
33
Poweredge R710
PCI Express Gen2 Slots
Slot 1: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width
Slot 2: Full-Length (12.2" Factory Installation) / Full-Height (x8 connector), x8 link width
Slot 3: Full-Length (12.2" Factory Installation) / Full-Height (x8 connector), x8 link width
Slot 4: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width
Slot 5: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width
Card PCIe Link Slot Max
Category Description Dell PN
Priority Width Priority Cards
Internal Storage T95
1 Dell™ PERC 6/i Integrated (Sled) Gen1 x8 Integrated 1
(Integrated Slot) 4J
Internal Storage YK8
2 Dell SAS 6/iR Integrated (Sled) Gen1 x8 Integrated 1
(Integrated Slot) 38
External Storage *Dell PERC 5/E Adapter GP2
3 Gen1 x8 Slot 4, 51 22
Controller (Test only, no factory install) 97
External Storage *Dell PERC 6/E Adapter Slot 3, 2,
4 J15 5F Gen1 x8 22
Controller (512MB) 5, 4, 1
External Storage *Dell PERC 6/E Adapter F98 Slot 3, 2,
5 Gen1 x8 22
Controller (256MB) 9F 5, 4, 1
*Intel 10GBase-T Copper Single XR9 Slot 4, 5, 1,
10Gb NIC 6 Gen1 x8 2
Port NIC (Copperpond) 97 2, 3
*Broadcom BCM57710
RK3 Slot 4, 5, 1,
10Gb NIC 7 10GBase-T Copper Single Port Gen1 x8 2
75 2, 3
NIC (Quiver)
Intel® 10GBase-SR Optical RN Slot 4, 5, 1,
10Gb NIC 8 Gen1 x8 2
Single Port NIC (BelleFontaine) 219 2, 3
External Storage M7 Slot 3, 2,
9 *Dell SAS 5/E Adapter Gen1 x8 22
Controller 78G 4, 5, 1
Internal Tape Dell SAS 5/iR Adapter UN Slot 3, 2,
10 Gen1 x8 22
Controller (for internal tape only) 939 4, 5, 1
Fibre Channel Emulex LPe12002 FC8 C85 Slot 4, 5, 1,
11 Gen2 x4 5
8 HBA Dual-Channel HBA 6M 2, 3
Fibre Channel Emulex LPe12000 FC8 C85 Slot 4, 5, 1,
12 Gen2 x4 5
8 HBA Single-Channel HBA 5M 2, 3
1
Thermal testing to determine if the PERC5 can be installed in other slots is pending.
2
A maximum of 2 nternal/external storage controllers (Dell PERC and SAS cards) are allowed in the system in addition to the integrated storage controller.
34
E. Boot Order
PCIe scan order (from the BIOS HW spec v1.0)
IOH port 1,2 (PCI Express Gen1 x4) – Broadcom BCM5709C Gigabit Embedded NIC #1
IOH port 3 (PCI Express Gen1 x4) – Broadcom BCM5709C Gigabit Embedded NIC #2
IOH port 4 in Bluefish or ICH9 port1-4 in Thidwick (PCI Express Gen1 x4) – Integrated PERC6i or SAS6i
on the Riser 1
IOH port 5 (PCI Express Gen2 x4) – Slot 2 on Riser 1
IOH port 6 (PCI Express Gen2 x4) – Slot 1 on Riser 1
IOH port 7/8 (PCI Express Gen2 x8) – Slot 3 on Riser 2
IOH port 9/10 (PCI Express Gen2 x8) – Slot 4 on Riser 2
For PCI-e X16 optional left riser, IOH port 7,8,9,10 are combined into one x16 PCI-e slot.
35
A. Overview / Description
The PowerEdge R710 supports three different backplanes to support different hard drive configurations:
six 3.5" hard drives, four 3.5" hard drives, or eight 2.5" hard drives.
On each backplane are two LED indicators per drive slot with one or two mini-SAS x4 cable connectors
for connecting the backplane to the integrated SAS 6/iR or PERC 6i, and a power connector to connect
to the planar. Both Serial Attached SCSI (SAS) and Serial ATA (SATA) hard drives are supported. For
SAS/SATA mixing, two SAS drives are supported with the 3.5" backplane.
B. Drives
I. Internal Hard Disk drives
The PowerEdge R710 supports up to eight 2.5" or six 3.5" hard disk drives.
• Support for 15,000 rpm 3.5" SAS drives
• Support for 10,000 and 15,000 rpm 2.5" SAS drives
• Support for 7,200 rpm 3.5" Near Line SAS drives
• Support for 7,200 rpm 3.5" and 2.5" Enterprise SATA drives
• Support for 7,200 rpm 3.5" and 2.5" SATAu drives
• For SAS/SATA mixing, two SAS and up to six SATA drives are possible
• A pair of SAS drives must be installed in slots 0 and 1
• One mixed 2.5" and 3.5" hard drive configuration is allowed:
• A pair of 2.5" 10k rpm SAS drives must be installed with an adapter in a 3.5" hard drive
carrier in drive slots 0 and 1
• The remaining hard drives must be 3.5" hard drives and must be either all SAS or all
SATA
• Support for 25 and 50GB 2.5" solid state drives at RTS (additional solid state drive support is
Post RTS)
• SSDs require the PERC 6/i Integrated storage controller and cannot be mixed with any other
type of hard drive
2.5 HDDs
2.5" Enterprise SATA 7.2K HDs 160GB, 250GB, and 500GB
2.5" SAS 10K HDs: 73GB, 146GB, and 300GB
2.5" entry 10K SAS in 3.5" HDD carrier
2.5" SAS 15K HDs 73GB and 146GB
2.5" Enterprise SATA SSD 25GB, 50GB, and 100GB
2.5" SSD 25GB and 50GB
3.5 HDDs
160GB, 250GB, 500GB, 750GB, and
Support for 3.5" Enterprise SATA 7.2K:
1,000GB
500GB SATAu, 750GB SATAu, and
Support for 3.5" Enterprise SATAu 7.2K:
1 ,000GB SATAu
Support for 3.5" Green Enterprise SATA 5.4K 1,000GB
Support for 3.5" Near Line SAS 7.2K 500GB, 750GB, and 1,000GB
Support for 3.5" SAS 15K HDs: 146GB, 300GB, and 450GB
Table: R710 supported HDD matrix
36
For mixed SAS/SATA configurations, SAS drives must be installed as a pair in drive slots 0 and 1.
One mixed 2.5" and 3.5" hard drive configuration is allowed: a pair of 2.5" 10k rpm SAS drives can be
installed with an adapter in a 3.5" hard drive carrier in drive slots 0 and 1. The remaining hard drives must
be 3.5" hard drives and must be either all SAS or all SATA.
PowerEdge
R710
Platforms 4
Mixed SSD/SAS** 4
Mixed SAS/SATA* 4
2.5" SAS HDD in 3.5" HDD Carrier + 3.5" SATA HDDs (Mixed SAS) 4
2.5" SAS HDD in 3.5" HDD Carrier + 3.5" SATA HDDs (Mixed SAS/SATA)* 4
• SAS HDDs should be in slots 0 & 1 and min/max number of SAS HDDs is 2, rest will be SATA
HDDs and min/max number of SATA HDDs depends on the configuration.
• **No maximum for SAS HDD’s combined with SSD
• ***SSD Support requires PERC 6/i
20GB and 50GB solid state drives (SSD) support will be supported at RTS
37
C. RAID Configurations
PowerEdge R710 Factory Configuration Summary
Integrated
SAS/SATA 2.5"=1 2.5"=8
0 MSS SAS/SATA No RAID
(No RAID) 3.5"=1 3.5"=8
(SAS 6/iR)
Integrated
2.5"=1* 2.5"=8
1 MSSR0 SAS/SATA RAID 0 N/A
3.5"=1* 3.5"=8
(SAS 6/iR, PERC6/I)
Integrated
2.5"=2 2.5"=2
2 MSSR1 SAS/SATA RAID 1 N/A
3.5"=2 3.5"=2
(SAS 6/iR, PERC6/I)
Integrated
2.5"=3 2.5"=8
3 MSSR5 SAS/SATA RAID 5 N/A
3.5"=3 3.5"=8
(PERC 6/i)
Integrated
2.5"=4 2.5"=8
SAS/SATA 4 MSSR6 SAS/SATA RAID 6 N/A
3.5"=4 3.5"=8
(RAID) (PERC 6/i)
Integrated
2.5"=4 2.5"=8
5 MSSR10 SAS/SATA RAID 10
3.5"=4 3.5"=8
(PERC 6/i)
Integrated
SAS/SATA RAID 2.5"=2+2 2.5"=2+2
6 MSSR1R1
1/RAID 1 3.5"=2+2 3.5"=2+2
(SAS 6/iR, PERC 6/i)
Integrated
2.5"=2+3 2.5"=2+6
7 MSSR1R5 SAS/SATA RAID
3.5"=2+3 3.5"=2+6
1/RAID 5 (PERC 6/i)
Integrated
SAS/SATA 2.5"=3 2.5"=6
8 MSS-X SAS/SATA No RAID
(No RAID) 3.5"=3 3.5"=6
(SAS 6/iR)
38
Integrated
SAS/SATA RAID 2.5"=2+2 2.5"=2+2
9 MSSR1R1- X
1/RAID 1 3.5"=2+2 3.5"=2+2
(SAS 6/iR, PERC 6/i) Mixed SSD/ SAs
SAS/SATA non-mixed Min 2xSSD+1xSAS
(RAID) drives, all SSD 2.5": Max 2xSSD + 6xSAS
config Integrated
configs description
type SAS/SATA RAID 2.5"=2+3 2.5"=2+6
10 MSSR1R5-X Min Max Min MAX
1/RAID 5 3.5"=2+3 3.5"=2+6
HDD HDD HDD HDD
(PERC 6/i)
Integrated SSD 2.5"=2 2.5"=2
11 MSSR1 N/A
RAID 1 (PERC 6/i) 3.5"=N/A 3.5"=N/A
D. Storage Controllers
I. SAS 6/iR
The PowerEdge R710 internal SAS 6/iR HBA is an expansion card that plugs into a dedicated PCI
Express x8 slot (only four lanes wired). It incorporates two four-channel SAS IOCs for connection to
SAS/SATA hard disk drives. It is designed in a form factor that allows the same card to be used in R610
and T610.
39
II. PERC 6i
For customers who want a hardware RAID solution, the PERC 6i is an option. The PERC 6i uses the LSI
1078 ROC (RAID on Chip) processor with a PCI Express host interface and DDR2 memory. A battery is
also available for backup.
0, 1,
Internal
5, 6,
PERC 6/i Backplane Storage x4 int
Yes, Max 1 x8 No 10, 50, Yes
Integrated Storage slot x4 int
and
(HDD, SSD)
60
PERC SAS/SATA
Yes, Max 2 0, 1,
External (MD1000 5, 6,
PERC 6/E PCIe x4 ext
SAS/SATA Pompano x8 Yes 10, 50, TBBU
Adapter slot x4 ext
Storage & MD1020 and
Ridgeback) 60
Yes, Max 2
External (MD1000,
PERC 5/E PCIe x4 ext 0, 1, 5,
Legacy Pompano, x8 Yes TBBU
Adapter slot x4 ext 10, 50
Storage & MD1020
Ridgeback)
Internal
SAS HBA SAS/SATA
Backplane
SAS 6/iR Storage Storage x4 int
Yes, Max 1 x8 No 0, 1 No
Integrated (No tape slot x4 int
or SSD
support)
External
SAS 5/E PCIe x4 ext
SAS (DAS, Yes, Max 2 x8 Yes none No
Adapter slot x4 ext
Tape)
Internal
slim-line Yes, 2
SATA ports for
ICH9
On Planar
Optical Optical n/a n/a n/a x1 int n/a n/a
via chipset
and/or and/or
TBU Only TBU
(no HDD)
Internal or
LSI 2032 SCSI
External
SCSI
SCSI
LSI 2032 PCIe int
Tape/ Yes, Max 2 x8 Yes n/a n/a
Adapter slot SCSI
Legacy
ext
External
storage
Note: A maximum of 2 external storage controllers (Dell PERC or SAS cards) are allowed in the system in
addition to the integrated storage controller.
40
E. LED Indicators
Each disk drive carrier has two LED indicators visible from the front of the system. One is a green LED
for disk activity and the other is a bicolor (green/amber) LED for status information. The activity LED is
driven by the disk drive during normal operation. The bicolor LED is controlled by the SEP device on the
backplane. Both LEDs are used to indicate certain conditions under direction of a storage controller.
F. Optical Drives
Optical drives are optional in all of the PowerEdge R710 systems and connect to the planar via the SATA
interface. The following internal slim-line drives are available on the PowerEdge R710: DVD-ROM and
DVD+RW. PATA (IDE) optical drives are not supported.
If an optical drive is not ordered with the system, a blank is installed in its place.
G. Tape Drives
Internal tape drives are optional in systems with the 4x3.5" or 8x2.5" backplanes. Internal SATA tape
drives connect directly to the SATA connector on the planar. Internal SCSI tape drives connect through
the LSI 2032 PCI Express SCSI adapter card.
TAPE DRIVES
41
A. Overview / Description
The PowerEdge R710 Integrated Dell Remote Access Controller 6 (iDRAC6) incorporates an integrated
video subsystem, connected to the 32-bit PCI interface of the ICH9. This logic is based on the Matrox
G200. The device only supports 2D graphics. The video device outputs are multiplexed between the
front and rear video ports. If a monitor is connected to the front video connector, it will take precedence
over the rear connection, thereby removing the display from the rear connection. The integrated video
core shares its video memory with the iDRAC6’s 128MB DDR2 application space memory. This memory
is also used for the KVM buffer.
The PowerEdge R710 system supports the following 2D graphics video modes:
42
A. Overview / Description
No speakers supported
A. Overview / Description
Rack installation components such as rails are provided with the PowerEdge R710 Rack Kit. The rack
installation components are as follows: Sliding Rack mount with latest generation Cable Management
Arm (CMA). When the system is installed in a rack, please observe the following guidelines:
Nothing should be located within 12" of the front of the unit that would restrict the airflow into the system.
Nothing should be mounted or placed behind the chassis that would restrict airflow from exiting the
system. Only Dell approved CMAs can be placed behind the chassis. All other objects should be located
at least 24" away from the rear of the chassis.
When two systems are placed back to back, the separation between the units should be at least 24" if
the exit airflow is equivalent for the two chassis. This allows the exit air to escape without creating an
extreme back pressure at the rear of one of the chassis.
Mouse – USB 1
Keyboard – USB 1
Video – VGA 1
Power Cords 2
LOMs – Ethernet 1
PCI NICs 1
Total 8
Notes: • CMA supports for the maximum number of cables supported by system
• The numbers in this matrix represent the number and types of external cables required to be
supported by the CMA solution.
• This matrix is built on the practical worst case configuration in each platform based on prior
and projected take rates. Note that other combinations of adapters and associated cables exist,
but are assumed to fall within these guidelines from the standpoint of bend radius and
flexibility, cable bundling, cable volume, etc.
• PCI NIC cables are assumed to be Ethernet.
• KVM cable dongle may be used for mouse/keyboard/video.
43
C. Rails
Support for tool-less installation in CEA-310-E compliant square hole 4-post racks including:
Support for Dell 2410 24U Rack
Support for Dell 4210 Rack
Support for HP/Compaq 10xxx series
Support for tooled or tool-less installation in CEA-310-E compliant round hole 4-post racks
(tool-less preferred)
Support for flush and center mount installation in CEA-310-E compliant 2-post racks (1U & 2U only)
44
A. Overview / Description
The PowerEdge R710 supports Windows®, Linux®, and Solaris™ Operating Systems.
Windows® Support:
x86
Factory logo Test/
or INSTALLATION schedule support
INSTALLATION certification Validate
x64
Windows® Small Business Server 2008 and Essential Business Server 2008
Windows
Standard/ Hardware
x64 Yes Shipping Yes Yes
Premium Quality Labs -
Windows 2008
Windows Server® 2008 (x64 includes Hyper-V™)
Standard
Windows
Hardware
x64 Enterprise Yes Shipping Yes Yes
Quality Labs -
Windows 2008
Datacenter
Windows Server® 2008
Standard Windows
Hardware
x86 Yes Shipping Yes Yes
Quality Labs -
Enterprise Windows 2008
Windows® Web Server 2008
x86 Windows
Hardware
and Web Yes Shipping Yes Yes
Quality Labs -
x64 Windows 2008
Windows Server® 2008, SP2 (x64 includes Hyper-V™)
Standard
Windows Available in
Hardware August -
x64 Enterprise Yes Yes Yes
Quality Labs - October
Windows 2008 2009
Datacenter
Windows Server® 2008, SP2
Windows Available in
x86
Hardware August -
and Web Yes Yes Yes
Quality Labs - October
x64 2009
Windows 2008
45
x86
Factory logo Test/
or INSTALLATION schedule support
INSTALLATION certification Validate
x64
Windows Server® 2008, R2, (x64 includes Hyper-V™)
Linux support:
Available in Available in
x64 Enterprise n/A Yes Yes
June 2009 June 2009
Solaris™ 10 05/09
Available in
x64 Enterprise Drop in the box n/A Yes Yes
June 2009
46
A. Overview / Description
Supported embedded hypervisors:
• Microsoft® Windows Server® 2008 Hyper-V
• VMware® ESXi Version 4.0 and 3.5 update 4
• Citrix® XenServer 5.0 with Hotfix 1 or later
A. Overview / Description
Dell is focused on delivering open, flexible, and integrated solutions the help our customers reduce the
complexity of managing disparate IT assets. We build comprehensive IT management solutions.
Combining Dell PowerEdge Servers with a wide selection of Dell-developed management solutions, we
provide customers choice and flexibility – so you can simplify and save in environments of any size.
To help you meet your server performance demands, Dell offers Dell OpenManage™ systems
management solutions for:
• Deployment of one or many servers from a single console
• Monitoring of server and storage health and maintenance
• Update of system, operating system, and application software
We offer IT management solutions for organizations of all sizes – priced right, sized right, and
supported right.
B. Server Management
A Dell Systems Management and Documentation DVD and a Dell Management Console DVD are included
with the product. ISO images are also available. The following sections briefly describe the content.
Dell Systems Build and Update Utility: Dell Systems Build and Update Utility assists in OS install and
pre-OS hardware configuration and updates.
OpenManage Server Administrator: The OpenManage Server Administrator (OMSA) tool provides a
comprehensive, one-to-one systems management solution, designed for system administrators to
manage systems locally and remotely on a network. OMSA allows system administrators to focus on
managing their entire network by providing comprehensive one-to-one systems management.
Management Console: Our legacy IT Assistant console is also included, as well as tools to allow access
to our remote management products. These tools include: Remote Access Service, for iDRAC, and the
BMC Management Utility.
Active Directory Snap-in Utility: The Active Directory Snap-in Utility provides an extension snap-in to
the Microsoft Active Directory. This allows you to manage Dell specific Active Directory objects. The
Dell-specific schema class definitions and their installation are also included on the DVD.
Dell Systems Service Diagnostics Tools: Dell Systems Service and Diagnostics tools deliver the latest
Dell optimized drivers, utilities, and operating system-based diagnostics that you can use to update
your system.
eDocs: The section includes Acrobat files for PowerEdge systems, storage peripheral and
OpenManage software.
47
Dell Management Console DVD: The Dell Management Console is a Web-based systems management
software that enables you to discover and inventory devices on your network. It also provides advanced
functions, such as health and performance monitoring of networked devices and patch management
capabilities for Dell systems.
Server Update Utility: In addition to the Systems Management Tools and Documentation and Dell
Management Console DVDs, customers have the option to obtain Server Update Utility DVD. This
DVD has an inventory tool for managing updates to firmware, BIOS and drivers for either Linux or
Windows varieties.
The iDRAC6 provides features for managing the server remotely or in data center lights-out
environments.
Advanced iDRAC features require the installation of the iDRAC6 Enterprise card.
The port on the control panel is for an optional USB key and is located inside the chassis. Some of the
possible applications of the USB key are:
• User custom boot and pre-boot OS for ease of deployment or diskless environments
• USB license keys for software applications like eToken™ or Sentinel Hardware Keys
• Storage of custom logs or scratch pad for portable user-defined information (not hot-pluggable)
The Internal SD Module is dedicated for an SD Flash Card with embedded Hypervisor for virtualization.
The SD Flash Card contains a bootable OS image for virtualized platforms.
Lifecycle controller is the hardware component that powers the embedded management features. It is
integrated and tamperproof storage for system-management tools and enablement utilities (firmware,
drivers, etc.). It is flash partitioned to support multiple, future use cases.
Dell Unified Server Configurator is a 1:1 user interface exposing utilities from Lifecycle Controller. Customers
will use this interface to configure hardware, update server, run diagnostics, or deploy the operating
system. This utility resides on Lifecycle Controller. To access the Unified Server Configurator, press <F10>
key within 10 seconds of the Dell logo display during the system boot process. Current functionality
enabled by the Unified Server Configurator includes:
48
feature description
Faster O/S Drivers and the installation utility are embedded on system, so no need to
Installation scour DELL.COM
Integration with Dell support automatically directed to latest versions
Faster System Updates of the Unified Server Configurator iDRAC, RAID, BIOS, NIC, and
Power Supply
Description: Ability to recover to previous “known good state” for all
Update Rollback
updatable components
More Comprehensive
Diagnostic utilities are embedded on system
Diagnostics
For more information on iDRAC6 Express features see the table below.
Additionally, the iDRAC6 Enterprise can be upgraded by adding the vFlash Media card. This is a 1GB
Dell branded SD card that enabled a persistent 256MB virtual flash partition. In the future, vFlash will be
expanded to include additional features.
49
A more detailed feature list for iDRAC6 Enterprise and vFlash is included in the table below.
Web-based GUI 4 4 4
SNMP 4 4 4
WSMAN 4 4 4
SMASH-CLP 4 4 4
Racadm command-line 4 4
Conductivity
Shared/Failover Network Modes 4 4 4 4
IPv4 4 4 4 4
VLAN tagging 4 4 4 4
IPv6 4 4 4
Dynamic DNS 4 4 4
Dedicated NIC 4 4
Local Users 4 4 4 4
Active Directory 4 4 4
SSL Encryption 4 4 4
Power capping 4 4 4
Boot capture 4 4 4
Serial-over-LAN 4 4 4
Virtual media 4 4
Virtual console 4 4
50
Virtual flash 4
Monitoring
Sensor Monitoring and Alerting 4 4 4 4
Logging Features
System Event Log 4 4 4 4
RAC Log 4 4 4
Trace Log 4 4 4
51
A. USB peripherals
The PowerEdge R710 supports the following USB devices:
• DVD (bootable; requires two USB ports)
• USB Key (bootable)
• Keyboard (only one USB keyboard is supported)
• Mouse (only one USB mouse is supported)
B. External Storage
external storage
52
53
Appendix
R710 Volatility Chart.
Non-
volatile Reference Type [e.g., Flash PROM,
Volatile QTY Size
ram designator EEPROM]:
RAM
Planar, Poweredge R710
System BIOS SPI Flash Y U_SPI_BIOS 1 4MB Flash EEPROM (SPI interface)
LOM Configuration Data Y U15, U16 2 512KB FLASH (NOR)
iDRAC6 Controller ROM Y U_IBMC 1 4KB ROM
iDRAC6 Controller RAM Y U_IBMC 1 8KB RAM
System CPLD Y U_CPLD 1 1200 Macro cells Internal Flash EEPROM
System CPLD Y U_CPLD 1 1KB RAM
iDRAC6 Express Internal Flash Y U_EMMC 1 1GB NAND FLASH
J_CPU(2:1)_
up to 18 DIMMs
System RAM Y CH(2:0)_ 18 *16GB
RAM
DIMM(3:1)
TPM ID EEPROM
Y U_SEEPROM 1 256B EEPROM
(Plug in module only)
TPM Binding EEPROM
Y U7261 1 256B EEPROM
(on China planar only)
U_IBMC_
iDRAC6 SDRAM Y 1 128MB DDR2 RAM
MEM
U_IBMC_
iDRAC6 FRU Y 1 4KB EEPROM
FRU
iDRAC6 Boot Block Flash Y U_IBMC_SPI 1 2MB FLASH (NOR)
Trusted Platform Module Y N U_TPM 1 128 bytes EEPROM
chipset
CMOS Y U_ICH9 1 256KB Battery backed RAM
2.5" backplane or 3.5" Backplane
Embedded Microcontroller
Storage Controller Processor Y U_SEP 1 32KB
Flash
control panel
J_USBKEY License key hard set ROM or
Internal USB Y 1 User selectable
user choice
(connector)
J_SDCARD User selectable -
Internal SD Module Y 1 1GB shipped
Secure Digital NAND Flash
(Connector)
Power Supply
Maximum
Varies by Up Embedded microcontroller
PSU Microcontroller Y supported = 2MB
flash
part number to 2 per PSU
PERC 6/i Integrated
PERC NVSRAM Config Data Y U23 1 32KB Non-volatile SRAM
PERC Firmware Y U24 1 4MB FLASH (NOR)
PERC Cache RAM Y U58-61 1 256MB RAM
FRU Y U40 1 256MB EEPROM
IBUTTON Key EEPROM Y U21 1 1KB EEPROM
CPLD Y U_CPLD 1 72 macrocells Internal Flash EEPROM
SAS 6/iR Integrated
Controller Configuration Data Y U3 1 4MB FLASH (NOR)
FRU Y U4 1 256KB EEPROM
Integrated Mirroring NVSRAM Y U1 1 32KB Non-volatile SRAM
iDRAC6 Enterprise
J_SD 1GB @ RTS,
VFlash Y 1 Larger later
Secure Digital NAND Flash
(connector)
54
55
56
57
58