0% found this document useful (0 votes)
11 views

Harmonics

Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views

Harmonics

Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Harmonic

Analysis

Flexible
Capable
Concise
W i t h E TA P ’ s H a r m o n i c A n a l y s i s m o d u l e , y o u c a n i d e n t i f y h a r m o n i c
problems, reduce nuisance trips, design and test filters, and report
distortion limit violations. Comprehensive load flow and frequency
scan calculations are performed using detailed harmonic models
a n d n o n - i n t e g e r h a r m o n i c f i l t e r s . R e s u l t s a r e s h o w n g r a p h i c a l l y,
including harmonic order, harmonic spectrum plots, and
h a r m o n i c w a v e f o r m p l o t s , a s w e l l a s d e t a i l e d C r y s t a l R e p o r t s ®.
Powerful Tools for Performance Engineers
Key Features Capabilities
harmonic analysis

• Harmonic Load Flow • Temperature-dependent line & cable resistances


• Single-tuned, high-pass, & band-pass filters
• Harmonic Frequency Scan • Create filters to shift resonance points
• Filter Design & Sizing • to less harmful frequencies
• Inter-Harmonic Filter Modeling • Model up to the seventy-first (71st) harmonic
• Automatically Evaluate Harmonic Limits • Identify & analyze telephone interference problems
• User-expandable harmonic source library
Flexible Operation • Identify resonance conditions
• Fundamental load flow results
• Bus impedance magnitude & angle Calculate
• as functions of frequency • Harmonic filter performance
• Time-domain waveform plots • Magnitude & angle of the
• Frequency-domain spectrum plots • system impedance at selected buses
• Includes phase shifting transformers • Telephone Interference Factor (TIF)
• Total Harmonic Distortion (THD)
• Root Mean Square (RMS)
• Arithematic Sum (ASUM)
• IEEE 519 indices
• I*T product

Reporting
• Fundamental load flow results
• Report voltage & current harmonic distortions
• Report RMS, ASUM, TIF, & I*T values
• Bus impedances (magnitude & angle) in tables
View Impedance and Load Flow • Text output reports including violation flags
Plots Simultaneously • Use Crystal Reports ® for full color, customizable reports
• Export output reports to your favorite word processor
• Graphical display of harmonic results
• Export one-line diagrams to third party CAD systems

Unlimited Buses* & Elements


No Voltage Limitations
Looped & Radial Systems
Integrated 1-Phase, 3-Phase, & DC Systems
Multiple Generators & Grid Connections
Multiple Isolated Sub-Systems
Customizable Libraries
Graphical Display of Results on One-Line Diagrams
Customizable Font Types, Sizes, Styles, & Colors
Customizable Display of Ratings & Results
Graphical Display of Equipment Impedance & Grounding
Automatic Error Checking
Graphical Display of Overstressed Devices
Graphical Display of Over/Under Voltage Buses
Dynamically Adjust Display of Results
*Maximum number of energized buses 10 CFR 50 Appendix B • 10 CFR 21 • ANSI/ASME N45.2-1977 • ASME NQA-1
during calculations is license dependent.
ISO 9001 A3147 • ANSI/IEEE Std 730.1-1989 • CAN/CSA-Q396.1.2-89

Operation Technology, Inc. • www.etap.com • 17 Goodyear • Irvine, CA 92618 • 949.462.0100 • Fax 949.462.0200

You might also like