Product data sheet

Specifications

IEC contactor, TeSys Deca,


nonreversing, 80A, 60HP at
480VAC, up to 100kA SCCR, 3
phase, 3 NO, 220VAC 50/60Hz
coil, open
LC1D80M7

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Range TeSys

Range Of Product TeSys Deca

Product Or Component Type Contactor

Device Short Name LC1D

Contactor Application Motor control


Resistive load

Utilisation Category AC-3


AC-3e
AC-4
AC-1

Poles Description 3P

[Ue] Rated Operational Voltage Power circuit <= 300 V DC 25...400 Hz


Power circuit <= 690 V AC

[Ie] Rated Operational Current 125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit

[Uc] Control Circuit Voltage 220 V AC 50/60 Hz

Complementary
Motor Power Kw 22 kW at 220...230 V AC 50/60 Hz (AC-3)
37 kW at 380...400 V AC 50/60 Hz (AC-3)
45 kW at 415...440 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 660...690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
22 kW at 220...230 V AC 50/60 Hz (AC-3e)
37 kW at 380...400 V AC 50/60 Hz (AC-3e)
45 kW at 415...440 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 660...690 V AC 50/60 Hz (AC-3e)

Maximum Horse Power Rating 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors
30 hp at 230/240 V AC 50/60 Hz for 3 phase motors
60 hp at 460/480 V AC 50/60 Hz for 3 phase motors
60 hp at 575/600 V AC 50/60 Hz for 3 phase motors

Compatibility Code LC1D

Pole Contact Composition 3 NO

Protective Cover With

Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.

Jun 10, 2024 1


[Ith] Conventional Free Air 10 A (at 140 °F (60 °C)) for signalling circuit
Thermal Current 125 A (at 140 °F (60 °C)) for power circuit

Irms Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947

Rated Breaking Capacity 1100 A at 440 V for power circuit conforming to IEC 60947

[Icw] Rated Short-Time Withstand 640 A 104 °F (40 °C) - 10 s for power circuit
Current 990 A 104 °F (40 °C) - 1 s for power circuit
135 A 104 °F (40 °C) - 10 min for power circuit
320 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1


200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit

Average Impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit

Power Dissipation Per Pole 5.1 W AC-3


12.5 W AC-1
5.1 W AC-3e

[Ui] Rated Insulation Voltage Power circuit 600 V CSA


Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL

Overvoltage Category III

Pollution Degree 3

[Uimp] Rated Impulse Withstand 8 kV IEC 60947


Voltage
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

Mechanical Durability 4 Mcycles

Electrical Durability 0.8 Mcycles 125 A AC-1 <= 440 V


1.5 Mcycles 80 A AC-3 <= 440 V
1.5 Mcycles 80 A AC-3e <= 440 V

Control Circuit Type AC 50/60 Hz standard

Coil Technology Without built-in suppressor module

Control Circuit Voltage Limits 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz


0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz
1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz

Inrush Power In Va 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))


245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))

Hold-In Power Consumption In Va 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))


26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))

Heat Dissipation 6…10 W at 50/60 Hz

Operating Time 20...35 ms closing


6...20 ms opening

Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)

2 Jun 10, 2024


Connections - Terminals Control circuit: screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) - cable stiffness:
flexible with cable end
Control circuit: screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) - cable stiffness:
flexible with cable end
Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) - cable stiffness:
flexible without cable end
Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) - cable stiffness:
flexible without cable end
Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) - cable stiffness:
solid without cable end
Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) - cable stiffness:
solid without cable end
Power circuit: connector 1 0.01…0.08 in² (4…50 mm²) - cable stiffness: flexible
without cable end
Power circuit: connector 2 0.01…0.04 in² (4…25 mm²) - cable stiffness: flexible
without cable end
Power circuit: connector 1 0.01…0.08 in² (4…50 mm²) - cable stiffness: flexible with
cable end
Power circuit: connector 2 0.01…0.02 in² (4…16 mm²) - cable stiffness: flexible with
cable end
Power circuit: connector 1 0.01…0.08 in² (4…50 mm²) - cable stiffness: solid without
cable end
Power circuit: connector 2 0.01…0.04 in² (4…25 mm²) - cable stiffness: solid without
cable end

Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm
Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2

Auxiliary Contact Composition 1 NO + 1 NC

Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1


Mirror contact 1 NC IEC 60947-4-1

Signalling Circuit Frequency 25...400 Hz

Minimum Switching Voltage 17 V for signalling circuit

Minimum Switching Current 5 mA for signalling circuit

Insulation Resistance > 10 MOhm for signalling circuit

Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact


1.5 ms on energisation between NC and NO contact

Mounting Support Plate


Rail

Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

Product Certifications GOST


RINA
CCC
CSA
BV
DNV
GL
LROS (Lloyds register of shipping)
UL

Ip Degree Of Protection IP20 front face IEC 60529

Protective Treatment THIEC 60068-2-30

Climatic Withstand IACS E10 exposure to damp heat

Permissible Ambient Air -40…140 °F (-40…60 °C)


Temperature Around The Device 140…158 °F (60…70 °C) with derating

Jun 10, 2024 3


Operating Altitude 0...9842.52 ft (0...3000 m)

Fire Resistance 1562 °F (850 °C) IEC 60695-2-1

Flame Retardance V1 conforming to UL 94

Mechanical Robustness Vibrations contactor open 2 Gn, 5...300 Hz)


Shocks contactor open 8 Gn for 11 ms)
Vibrations contactor closed 3 Gn, 5...300 Hz)
Shocks contactor closed 10 Gn for 11 ms)

Height 5.00 in (127 mm)

Width 3.35 in (85 mm)

Depth 5.12 in (130 mm)

Net Weight 3.51 lb(US) (1.59 kg)

Ordering and shipping details


Category US10I1222359

Discount Schedule 0I12

Gtin 3389110442571

Returnability Yes

Country Of Origin US

Packing Units
Unit Type Of Package 1 PCE

Number Of Units In Package 1 1

Package 1 Height 5.51 in (14.000 cm)

Package 1 Width 5.31 in (13.500 cm)

Package 1 Length 3.94 in (10.000 cm)

Package 1 Weight 3.44 lb(US) (1.560 kg)

Unit Type Of Package 2 S02

Number Of Units In Package 2 5

Package 2 Height 5.91 in (15.000 cm)

Package 2 Width 11.81 in (30.000 cm)

Package 2 Length 15.75 in (40.000 cm)

Package 2 Weight 17.82 lb(US) (8.085 kg)

Unit Type Of Package 3 P06

Number Of Units In Package 3 80

Package 3 Height 29.53 in (75.000 cm)

Package 3 Width 23.62 in (60.000 cm)

Package 3 Length 31.50 in (80.000 cm)

Package 3 Weight 293.88 lb(US) (133.300 kg)

Contractual warranty
Warranty 18 months

4 Jun 10, 2024


Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-
class environmental performance. Green Premium promises compliance with the latest regulations,
transparency on environmental impacts, as well as circular and low-CO2 products.
Guide to assessing product sustainability is a white paper that clarifies global eco-label
standards and how to interpret environmental declarations.
Learn more about Green Premium arrow2_right
Guide to assess a product’s sustainability arrow2_right

Transparency RoHS/REACh

Well-being performance

 Reach Free Of Svhc

 Toxic Heavy Metal Free

 Mercury Free

 Rohs Exemption Information Yes

 Pvc Free

Certifications & Standards


Reach Regulation REACh Declaration

Eu Rohs Directive Compliant

EU RoHS Declaration

China Rohs Regulation China RoHS declaration


Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure Product Environmental Profile

Weee The product must be disposed on European Union markets following specific waste
collection and never end up in rubbish bins.

Circularity Profile No need of specific recycling operations

California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide &
Antimony trioxide, which is known to the State of California to cause cancer. For
more information go to www.P65Warnings.ca.gov

Jun 10, 2024 5


Product data sheet LC1D80M7

Dimensions Drawings

Dimensions

(1) Minimum electrical clearance

LC1 D80 D95

a 85 85

with LA4 D●2 135 135

with LA4 DB3 or LAD 4BB3 135 –


b1
with LA4 DF, DT 142 142

with LA4 DM, DW, DL 150 150

without cover or add-on blocks 125 125


c
with cover, without add-on blocks 130 130

with LAD N (1 contact) 150 150


c1
with LAD N or C (2 or 4 contacts) 158 158

c2 with LA6 DK10, LAD 6DK 170 170

with LAD T, R, S 178 178


c3
with LAD T, R, S and sealing cover 182 182

6 Jun 10, 2024