Specifications
Main
Range Of Product Altivar Soft Starter ATS480
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product Or Component Type Soft starter
Phase 3 phase
[Ie] Rated Operational Current Normal duty 75.0 A 104 °F (40 °C))
Rated Current In Heavy Duty 62.0 A at 104 °F (40 °C) heavy duty
Motor Power Kw 18.5 kW 230 V in the motor supply line normal duty
15.0 kW 230 V in the motor supply line heavy duty
37.0 kW 400 V in the motor supply line normal duty
30.0 kW 400 V in the motor supply line heavy duty
37.0 kW 440 V in the motor supply line normal duty
30.0 kW 440 V in the motor supply line heavy duty
45.0 kW 500 V in the motor supply line normal duty
37.0 kW 500 V in the motor supply line heavy duty
45.0 kW 525 V in the motor supply line normal duty
37.0 kW 525 V in the motor supply line heavy duty
55.0 kW 660 V in the motor supply line normal duty
45.0 kW 660 V in the motor supply line heavy duty
55.0 kW 690 V in the motor supply line normal duty
45.0 kW 690 V in the motor supply line heavy duty
37.0 kW 230 V to the motor delta terminals normal duty
30.0 kW 230 V to the motor delta terminals heavy duty
55.0 kW 400 V to the motor delta terminals normal duty
55.0 kW 400 V to the motor delta terminals heavy duty
Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
Complementary
Device Connection In the motor supply line
To the motor delta terminals
Product Certifications CE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
Marking CE
CCC
UKCA
EAC
RCM
CULus
Analogue Output Type Current output AQ1 0...20 mA or 0...10 V 500 Ohm
Environment
Ambient Air Temperature For 104…140 °F (40…60 °C) with current derating of 2 % per °C)
Operation 5…104 °F (-15…40 °C) without derating)
Gtin 3606481089052
Returnability Yes
Country Of Origin CN
Packing Units
Unit Type Of Package 1 PCE
Transparency RoHS/REACh
Resource performance
Well-being performance
Mercury Free
Weee The product must be disposed on European Union markets following specific waste
collection and never end up in rubbish bins.
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead
compounds, which is known to the State of California to cause cancer and birth
defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
Dimensions Drawings
Dimensions
Power Connections
(1) : Installation of additional fast-acting fuses to upgrade to type 2 coordination according to IEC 60947–4–2.
(2) : Take into account the electrical characteristics of the relays (Control Terminal Characteristics).
(3) : The transformer must supply 110...230 VAC +10% — 15%, 50/60Hz.
(4) : RUN and STOP Management (3-wire control).
(5) : RUN and STOP Management (2-wire control).
Connection in line, with line and bypass contactor, freewheel or controlled stop, type 1 or
2 coordination, non reversing, 2-wire or 3-wire
(1) : Installation of additional fast-acting fuses to upgrade to type 2 coordination according to IEC 60947–4–2.
(2) : Take into account the electrical characteristics of the relays (Control Terminal Characteristics).
(3) : The transformer must supply 110...230 VAC +10% – 15%, 50/60Hz.
(4) : Take into account the electrical characteristics of the relays, especially when connecting to high rating contactor
(Control Terminal Characteristics).
(5) : RUN and STOP Management (3-wire control).
(6) : RUN and STOP Management (2-wire control).
(7) : PC or PLC control
Connection inside the delta, with line and bypass contactor, type 1 and 2 coordination,
non reversing, 2 wire or 3 wire
(1) : Installation of additional fast-acting fuses to upgrade to type 2 coordination according to IEC 60947–4–2.
(2) : Take into account the electrical characteristics of the relays (Control Terminal Characteristics).
(3) : The transformer must supply 110...230 VAC +10% – 15%, 50/60Hz.
(4) : Take into account the electrical characteristics of the relays, especially when connecting to high rating contactor
(Control Terminal Characteristics).
(5) : RUN and STOP Management (3-wire control).
(6) : RUN and STOP Management (2-wire control).
(7) : PC or PLC control
Mounting Position