Koncar MES IECEx CES14 - 0009X Issue 4 Mot - 7AT 71 315 CURRENT
Koncar MES IECEx CES14 - 0009X Issue 4 Mot - 7AT 71 315 CURRENT
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Optional accessory:
Type of Protection: Flameproof enclosures ‘d’; Increased safety 'e'; Dust ignition protection 't'
Marking: Ex db I Mb or Ex db eb IMb
and
Ex db IIB T3 Gb or Ex db eb IIB T3 Gb
Ex tb IIIC T160ºC Db
Signature:
(for printed version)
Date:
Additional
manufacturing
locations:
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended
STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards
IEC 60079-1:2014-06 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:7.0
IEC 60079-31:2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2
IEC 60079-7:2017 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:5.1
This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.
Test Reports:
IT/CES/ExTR14.0011/00 IT/CES/ExTR14.0011/01 IT/CES/ExTR14.0011/02
IT/CES/ExTR14.0011/03 IT/CES/ExTR14.0011/04
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
The motors are manufactured with separate compartments: motor (Ex db) and terminal box (Ex db or Ex eb) for supply and auxiliary circuits
connection or can be provided with permanently connected cable.
Only for group II and III, the motors series 7AT 71 ÷ 315 can be assembled with two “Ex d” terminal boxes (connected by sealing bushing + 3
piece fitting or by barrier cable glands and cable) or with two “Ex e” terminal boxes (connected by piece fitting or by cable glands and cable).
The motors can be equipped with auxiliary devices such as heaters, thermal detectors, brake and encoder.
The three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315, can be manufactured with efficiency
class IE1, IE2 and IE3 according to EN 60034-30 standard.
• 800 N/mm2 for motors size 71, 80, 90, 100, 112, 132, 160, 180, 280 and 315;
• 1200 N/mm2 for motors size 200, 225 and 250.
• The motor provided with the cables permanently connected, shall have these cables protected against the risk of damage due to
mechanical stresses. The free end connections shall be made according to one of the types of protection indicated in the IEC 60079-0
standard according to the installation rules in force in the site of
• The motor for group I (Mb) type 7AT size 71, 80, 90, 100, 112 was tested for low risk of mechanical danger and it shall be additionally
protected against impact.
• The flamepaths are specified in the manufacturer drawings. For information regarding the dimensions of the flameproof joints the
manufacturer shall be contacted.
• For motors painted with non-conductive dry film having thickness > 0.2 mm, the following label shall be applied: “Warning – potential
electrostatic charging hazard. Clean with damp cloth”
IECEx Certificate
of Conformity
Certificate No.: IECEx CES 14.0009X Page 4 of 4
Variation 4.1 - New motor sizes IEC 71, 80, 90S/L (shorter version than previous size 90, now called 90LX).
Variation 4.3 - Assessment for temperature class T6 for complete motor range 7AT 71÷315 (design T6; Practice 3 + Appendix 7 + Appendix 8).
Variation 4.6 - The motors series 7AT, originally assessed in compliance with IEC 60079-7 Ed. 5th 2015 has been reassessed on the basis of
the new standard IEC 60079-7 Ed. 5.1th: 2017.
Annex:
Description of equipment
The three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315
are manufactured by different constructive typologies; they can be supplied by mains or by inverter, with
simple or double polarity, self-ventilated or with forced ventilation.
The motors can be manufactured with two separate compartments: motor (Ex db) and terminal box (Ex db or
Ex eb) for supply and auxiliary circuits connection or can be provided with permanently connected cable.
Only for group II and III, the motors series 7AT 71 ÷ 315 can be assembled with two “Ex d” terminal boxes
(connected by sealing bushing + 3 piece fitting or by barrier cable glands and cable) or with two “Ex e” terminal
boxes (connected by piece fitting or by cable glands and cable).
For all motors of group I, aluminium alloy, as material, is excluded.
The motors can be equipped with auxiliary devices such as heaters, thermal detectors, brake and encoder.
The three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315,
can be manufactured with efficiency class IE1, IE2 and IE3 according to EN 60034-30 standard.
The motors with efficiency level IE2 and IE3, differ from standard motors IE1 for better quality of laminations,
higher length of stator/rotor package and higher filling factor of copper. The motors with efficiency class IE2
and IE3 are identified by proper code and the level of the efficiency class is stated on name plate.
The motors, for temperature class T3/T4, are produced with insulation system in class F and are designed
with temperature limit of the insulation class B (120°C) at ambient temperature Ta = +40°C.
The motors series 7AT 71÷315, for gas group IIC, can be protected from corrosion with a top layer of
conductive paint or alternatively with a layer of non-conductive dry film having thickness > 0.2 mm, in this last
case, the following label shall be applied: “Warning – potential electrostatic charging hazard. Clean with
damp cloth”.
Marking:
Depending on of type of protection, the motor series 7AT 71 ÷ 315, for group I can be marked as follows:
Ex db I Mb
Ex db eb IMb
Depending on of type of protection and ambient temperature, the motor series 7AT 71 ÷ 315, for groups II,
and III can be marked as follows:
Page1 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315
Marking (follows):
Model identification
The various motors types are identified by a code as follows:
A B C D E F G H I J K
Page2 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315
Electrical characteristics
Main electrical characteristics of motors series 7AT..., with Temperature classes T3 and T4
Supply by mains
Maximum voltage: 750 V
Maximum rated power (S1 duty) 225 kW
Maximum rated current: 335 A
Rated frequency: 50 / 60 Hz
Rated speed: 750 ÷ 3600 rpm
Insulation class: F-H (with t B)
Duty: S1 S10
Number of poles: 28
Degree of protection: IP54 or IP 55 or IP 56 or IP 65 or IP 66
IP67 (for “Ex db” motors only)
The anticondensation heaters installed inside the motor can have a maximum power of 130 W
The equipment, in Ex db execution only, has been separately tested against the requirements of IEC 60034-
5 and IEC 60529 and it meets IP67.
The three-phase asynchronous motors supplied by inverter are provided with a suitable label reporting
electrical operating characteristics; they shall be provided, inside the stator winding, with thermal detectors
(PTC) or thermal switches (TP); these thermal detectors shall be connected to suitable protection devices of
the supply system.
The operation of the thermal detector shall guarantee the disconnection of the supply at:
- 150 °C maximum for motors with temperature class T3.
- 130 °C maximum for motors with temperature class T4.
The operation of the thermal detector shall guarantee the disconnection of the supply; the resetting of the supply
shall not be automatic.
Page3 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315
Main electrical characteristics of motors series 7AT.., with Temperature class T5 and Ta > + 40°C
Main electrical characteristics of motors series 7AT.., with Temperature class T6 and Ta > + 40°C
Brake and/or encoder, coupled to the motor, shall be suitable for group, type of protection and ambient
temperature range foreseen from the motor (brake and encoder not available for Ta + 80°C).
Motors with forced ventilation unit (only for motors size 132 ÷315)
These machines are provided with a motor-driven blower mounted on the primary motor. The motor used for
forced ventilation shall be suitable for group, type of protection and ambient temperature range foreseen from
the primary motor. The operation of the primary motor shall be interlocked to the correct operation of the forced
ventilation.
Page4 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315
Warning label
For motors size 315LB, motors without terminal box and motors with ambient temperature +60°C:
“Supply cables of motors shall be suitable at least for an operating temperature of 92°C”.
Installation conditions
The accessories used for cable entries and for closing unused openings shall be certified according to the
following’s standards:
- IEC 60079-0 and IEC 60079-1 for motors and terminal box with type of protection “Ex db”
- IEC 60079-0 and IEC 60079-7 for terminal box with type of protection “Ex eb”
- IEC 60079-0 and IEC 60079-31 for motors and terminal box with type of protection “Ex tb”
If cylindrical threads are used the coupling between the cable gland and terminal box shall be provided with
block to prevent loosening.
Page5 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia