0% found this document useful (0 votes)
77 views9 pages

Koncar MES IECEx CES14 - 0009X Issue 4 Mot - 7AT 71 315 CURRENT

Uploaded by

stahlmob5657
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views9 pages

Koncar MES IECEx CES14 - 0009X Issue 4 Mot - 7AT 71 315 CURRENT

Uploaded by

stahlmob5657
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx CES 14.0009X Page 1 of 4 Certificate history:


Issue 3 (2020-07-31)
Status: Current Issue No: 4 Issue 2 (2017-04-04)
Issue 1 (2016-07-29)
Date of Issue: 2021-11-29 Issue 0 (2014-09-30)

Applicant: KONCAR - MES d.d.


(KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22
HR–10002 Zagreb
Croatia

Equipment: Three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315

Optional accessory:

Type of Protection: Flameproof enclosures ‘d’; Increased safety 'e'; Dust ignition protection 't'

Marking: Ex db I Mb or Ex db eb IMb

Ex db IIC T3,T4,T5,T6 Gb or Ex db eb IIC T3,T4,T5,T6 Gb

Ex tb IIIC T160°C, T130°C, T100°C Db

and

Ex db IIB T3 Gb or Ex db eb IIB T3 Gb

Ex tb IIIC T160ºC Db

Approved for issue on behalf of the IECEx Mirko Balaz


Certification Body:

Position: Head of IECEx CB

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting www.iecex.com or use of this QR Code.

Certificate issued by:


CESI
Centro Elettrotecnico
Sperimentale Italiano S.p.A.
Via Rubattino 54
20134 Milano
Italy
IECEx Certificate
of Conformity
Certificate No.: IECEx CES 14.0009X Page 2 of 4

Date of issue: 2021-11-29 Issue No: 4

Manufacturer: KONCAR - MES d.d.


(KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22
HR–10002 Zagreb
Croatia

Additional
manufacturing
locations:

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended

STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards

IEC 60079-0:2017 Explosive atmospheres - Part 0: Equipment - General requirements


Edition:7.0

IEC 60079-1:2014-06 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:7.0

IEC 60079-31:2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2

IEC 60079-7:2017 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:5.1

This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in:

Test Reports:
IT/CES/ExTR14.0011/00 IT/CES/ExTR14.0011/01 IT/CES/ExTR14.0011/02
IT/CES/ExTR14.0011/03 IT/CES/ExTR14.0011/04

Quality Assessment Report:


IT/CES/QAR10.0010/11
IECEx Certificate
of Conformity
Certificate No.: IECEx CES 14.0009X Page 3 of 4

Date of issue: 2021-11-29 Issue No: 4

EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:

Three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315 are manufactured by different


constructive typologies; they can be supplied by mains or by inverter, with simple or double polarity, self-ventilated or with forced ventilation.

The motors are manufactured with separate compartments: motor (Ex db) and terminal box (Ex db or Ex eb) for supply and auxiliary circuits
connection or can be provided with permanently connected cable.

Only for group II and III, the motors series 7AT 71 ÷ 315 can be assembled with two “Ex d” terminal boxes (connected by sealing bushing + 3
piece fitting or by barrier cable glands and cable) or with two “Ex e” terminal boxes (connected by piece fitting or by cable glands and cable).

For all motors of group I, aluminium alloy, as material, is excluded.

The motors can be equipped with auxiliary devices such as heaters, thermal detectors, brake and encoder.

The three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315, can be manufactured with efficiency
class IE1, IE2 and IE3 according to EN 60034-30 standard.

See annex for further description.

SPECIFIC CONDITIONS OF USE: YES as shown below:


• Supply cables of motors size 315LB, motors without terminal box and motors for the ambient temperature +60°C shall be suitable for an
operating temperature equal or greater than 92°C;
• The motors for ambient temperature +80°C the supply cable shall be suitable for an operating temperature equal or greater than 105°C.
• Screws used for fastening the parts of motor enclosure, shields and terminal box shall have a yield strength equal or higher than:

• 800 N/mm2 for motors size 71, 80, 90, 100, 112, 132, 160, 180, 280 and 315;
• 1200 N/mm2 for motors size 200, 225 and 250.
• The motor provided with the cables permanently connected, shall have these cables protected against the risk of damage due to
mechanical stresses. The free end connections shall be made according to one of the types of protection indicated in the IEC 60079-0
standard according to the installation rules in force in the site of
• The motor for group I (Mb) type 7AT size 71, 80, 90, 100, 112 was tested for low risk of mechanical danger and it shall be additionally
protected against impact.
• The flamepaths are specified in the manufacturer drawings. For information regarding the dimensions of the flameproof joints the
manufacturer shall be contacted.
• For motors painted with non-conductive dry film having thickness > 0.2 mm, the following label shall be applied: “Warning – potential
electrostatic charging hazard. Clean with damp cloth”
IECEx Certificate
of Conformity
Certificate No.: IECEx CES 14.0009X Page 4 of 4

Date of issue: 2021-11-29 Issue No: 4

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above)


Variations indicated below, refer to issue 4 of CoC IECEx CES 14.0009X:

Variation 4.1 - New motor sizes IEC 71, 80, 90S/L (shorter version than previous size 90, now called 90LX).

Variation 4.2 - New terminal box 7AT 71÷112 (Ex eb).

Variation 4.3 - Assessment for temperature class T6 for complete motor range 7AT 71÷315 (design T6; Practice 3 + Appendix 7 + Appendix 8).

Variation 4.4 - Motors for mining application (Ex db I Mb; Ex db eb I Mb).

Variation 4.5 - Corrosion protection system for motors in group IIC.

Variation 4.6 - The motors series 7AT, originally assessed in compliance with IEC 60079-7 Ed. 5th 2015 has been reassessed on the basis of
the new standard IEC 60079-7 Ed. 5.1th: 2017.

Annex:

Koncar-MES IECEx CES14_0009X ANNEX Issue 4 - 7AT 71-315.pdf


IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315

Description of equipment
The three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315
are manufactured by different constructive typologies; they can be supplied by mains or by inverter, with
simple or double polarity, self-ventilated or with forced ventilation.
The motors can be manufactured with two separate compartments: motor (Ex db) and terminal box (Ex db or
Ex eb) for supply and auxiliary circuits connection or can be provided with permanently connected cable.
Only for group II and III, the motors series 7AT 71 ÷ 315 can be assembled with two “Ex d” terminal boxes
(connected by sealing bushing + 3 piece fitting or by barrier cable glands and cable) or with two “Ex e” terminal
boxes (connected by piece fitting or by cable glands and cable).
For all motors of group I, aluminium alloy, as material, is excluded.
The motors can be equipped with auxiliary devices such as heaters, thermal detectors, brake and encoder.
The three-phase asynchronous motors series 7AT 71-80-90-100-112-132-160-180-200-225-250-280-315,
can be manufactured with efficiency class IE1, IE2 and IE3 according to EN 60034-30 standard.
The motors with efficiency level IE2 and IE3, differ from standard motors IE1 for better quality of laminations,
higher length of stator/rotor package and higher filling factor of copper. The motors with efficiency class IE2
and IE3 are identified by proper code and the level of the efficiency class is stated on name plate.
The motors, for temperature class T3/T4, are produced with insulation system in class F and are designed
with temperature limit of the insulation class B (120°C) at ambient temperature Ta = +40°C.
The motors series 7AT 71÷315, for gas group IIC, can be protected from corrosion with a top layer of
conductive paint or alternatively with a layer of non-conductive dry film having thickness > 0.2 mm, in this last
case, the following label shall be applied: “Warning – potential electrostatic charging hazard. Clean with
damp cloth”.

Marking:
Depending on of type of protection, the motor series 7AT 71 ÷ 315, for group I can be marked as follows:

Ex db I Mb
Ex db eb IMb

Depending on of type of protection and ambient temperature, the motor series 7AT 71 ÷ 315, for groups II,
and III can be marked as follows:

Ex db IIC T3, T4, T5,T6 Gb Ambient Temperature: - 20°C / +40°C


Ex db eb IIC T3, T4, T5, T6 Gb
Ex tb IIIC T160°C, T130°C, T100°C Db

Ex db IIC T3, T4 Gb Ambient Temperature: - 20°C / +40°C/ + 50°C / +60°C


Ex db eb IIC T3, T4 Gb
Ex tb IIIC T160°C, T130°C Db

Ex db IIB T3 Gb Ambient Temperature: - 20°C / +80°C


Ex db eb IIB T3 Gb
Ex tb IIIC T160°C Db

Temperature Class T5 and Ambient Temperature +45°C


Only for Motor types: 180 M-4 (max. Power 15.0 kW); 200 L-4 (max. Power 22.0 kW);
Ex db IIC T5 Gb
Ex db eb IIC T5 Gb

Temperature Class T5 and Ambient Temperature +50°C


Only for Motor type 132M-4 (max. Power 5.0 kW);
Ex db IIC T5 Gb
Ex db eb IIC T5 Gb

Page1 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315

Marking (follows):

Temperature Class T6 and Ambient Temperature +45°C


Only for Motor type: 132MA-4 (max. Power 4.8 kW)
Ex db IIC T6 Gb
Ex db eb IIC T6 Gb

Model identification
The various motors types are identified by a code as follows:

A B C D E F G H I J K

A = Efficiency class: Blank = IE1; E = IE2; H = IE3


B = Motor series: 7- motors with cast iron frame
C = Type of motor:
AT = basic design of single-speed motor
ATP = multi-speed motor with constant torque at all speed
ATPV = multi-speed fan rated motor
ABT = single-speed marine motor
ABTP = multi-speed marine motor with constant torque at all speed
ABTPV = multi-speed fan rated marine motor
D = Additional code (single or in combination)
A = motor with special mounting dimension
E = motor with special electric design
K = motor with electromagnetic brake
E = Motor frame size (71-80-90-100-112-132-160-180-200-225-250-280-315)
F = Frame length: S = Short, M = Medium, L = Long and X for longer frame (SX, MX, LX)
G = Power designation, power according to stator and rotor length: A,B,C,.. or
RA, RB, …; (R= for reduced power in bigger frame)
H = Number of poles: (2  8); (4/2...., 8/4/2; 6/4/2; ...)
I = Type of protection
D = motor in type of protection ”explosion-proof enclosure-d” and terminal box in type of
protection “explosion-proof enclosure-d”, design Ex db IIC (IIB)
E = motor in type of protection ”explosion-proof enclosure-d” and terminal box in type of
protection “increased safety-e”, design Ex db eb IIC (IIB)
K = motor in type of protection ”explosion-proof enclosure-d” equipped with frame lid on which
the certified cable bushing or cable gland in type of protection ”explosion-proof enclosure-
d” is mounted, design Ex db IIC (IIB)
R1- motor in Ex protection “db” and terminal box in Ex protection “eb” with certified cable
plugs (design Ex db eb I)
R2- motor in Ex protection “db” and terminal box in Ex protection “db” with certified cable plugs,
or with direct cable entry (barrier cable glands) – (design Ex db I)
P = Ex tb IIIC - motor in type of protection “tb”
J = Code of additionally mounted equipment (single or in combination)
A = motor with space heaters
G = motor with encoder
T = motor with thermal protection
V = motor with forced ventilation unit and certified driving motor
K = Temperature Class (Gas); T3; T4; T5; T6
Max Surface temperature (Dust): T160°C; T130°C; T100°C

Page2 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315

Electrical characteristics

Main electrical characteristics of motors series 7AT..., with Temperature classes T3 and T4

Supply by mains
Maximum voltage: 750 V
Maximum rated power (S1 duty) 225 kW
Maximum rated current: 335 A
Rated frequency: 50 / 60 Hz
Rated speed: 750 ÷ 3600 rpm
Insulation class: F-H (with t B)
Duty: S1  S10
Number of poles: 28
Degree of protection: IP54 or IP 55 or IP 56 or IP 65 or IP 66
IP67 (for “Ex db” motors only)

Ambient temperature: -20  +40 °C (standard motors)


-20  +50 °C (motors provided with permanently connected cables)
-20  +60°C (on demand)
-20  +80 °C (only for group IIB motors, with power derating for
reducing the winding rise-temperature within the limits of
the insulation class B (120 °C))

The anticondensation heaters installed inside the motor can have a maximum power of 130 W

The equipment, in Ex db execution only, has been separately tested against the requirements of IEC 60034-
5 and IEC 60529 and it meets IP67.

Motors supplied by inverter


Maximum voltage: 750 V
Peak voltage maximum: 1060 V
Frequency range: 5  87 Hz (motors 2p=2)
5  100 Hz (motors 2p=4, 6, 8)

The three-phase asynchronous motors supplied by inverter are provided with a suitable label reporting
electrical operating characteristics; they shall be provided, inside the stator winding, with thermal detectors
(PTC) or thermal switches (TP); these thermal detectors shall be connected to suitable protection devices of
the supply system.

The operation of the thermal detector shall guarantee the disconnection of the supply at:
- 150 °C maximum for motors with temperature class T3.
- 130 °C maximum for motors with temperature class T4.
The operation of the thermal detector shall guarantee the disconnection of the supply; the resetting of the supply
shall not be automatic.

Page3 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315

Electrical characteristics (follows)

Main electrical characteristics of motors series 7AT.., with Temperature class T5 and Ta > + 40°C

Motor 180 M-4 200 L-4 132M-4


Rated Voltage (V) 400 575 690 480 690 400 440
Rated Power -S1 (kW) 15.0 13.3 15.0 22.0 22.0 5.0 5.5
Rated frequency (Hz) 60 50 60 50 50 50 60
Rated current (A) 29.8 17.2 17.2 63.0 23.0 10.0 10.0
Number of poles 4 4 4 4 4 4 4
Connection delta star star delta delta delta delta
Temperature Class T5 T5 T5 T5 T5 T5 T5
Ambient Temp.(°C) -20  + 45°C 20  + 50°C
Degree of protection IP 54 or IP 55 or IP 56 or IP 65 or IP 66 or IP67 (for Ex db” only)

Main electrical characteristics of motors series 7AT.., with Temperature class T6 and Ta > + 40°C

Motor 132 MA-4


Rated Voltage (V) 440
Rated Power -S1 (kW) 4.8
Rated frequency (Hz) 60
Rated current (A) 8.4
Number of poles 4
Connection delta
Temperature Class T6
Ambient Temperature (C°) -20  + 45°C
Degree of protection IP 54 or IP 55 or IP 56 or IP65 or IP66 or IP67 (for Ex db” only)

Motors with brake and/or encoder

Brake and/or encoder, coupled to the motor, shall be suitable for group, type of protection and ambient
temperature range foreseen from the motor (brake and encoder not available for Ta + 80°C).

Motors with forced ventilation unit (only for motors size 132 ÷315)

These machines are provided with a motor-driven blower mounted on the primary motor. The motor used for
forced ventilation shall be suitable for group, type of protection and ambient temperature range foreseen from
the primary motor. The operation of the primary motor shall be interlocked to the correct operation of the forced
ventilation.

Page4 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia
IECEx Certificate of Conformity CESI
Prot: C1016415
Annex to certificate: IECEx CES 14.0009X Issue No.4 of 2021-11-29
Applicant: KONCAR - MES d.d. (KONCAR – MALI ELEKTRICNI STROJEVI d.d.)
Fallerovo setaliste 22, HR – 10002 Zagreb, Croatia
Electrical Apparatus: Three-phase asynchronous motors series
7AT 71-80-90-100-112-132-160-180-200-225-250-280-315

Warning label

“Warning - Do not open when energized”.

For motors size 315LB, motors without terminal box and motors with ambient temperature +60°C:
“Supply cables of motors shall be suitable at least for an operating temperature of 92°C”.

For motor supply by inverter:


“Winding protected with PTC thermistors or TP thermal switches”

In case of use of anticondensation heaters:


“Warning – energised resistors”.

In case of paint with nonconductive dry film thickness > 0.2 mm


“Warning – potential electrostatic charging hazard. Clean with damp cloth”

Installation conditions

The accessories used for cable entries and for closing unused openings shall be certified according to the
following’s standards:

- IEC 60079-0 and IEC 60079-1 for motors and terminal box with type of protection “Ex db”
- IEC 60079-0 and IEC 60079-7 for terminal box with type of protection “Ex eb”
- IEC 60079-0 and IEC 60079-31 for motors and terminal box with type of protection “Ex tb”

If cylindrical threads are used the coupling between the cable gland and terminal box shall be provided with
block to prevent loosening.

Page5 of 5
CESI - Centro Elettrotecnico Sperimentale Italiano SpA; I - 20134 Milano – Italia

You might also like