Meditec M700 Series

Patient Monitors
Advanced Monitoring Parameters

ECG-CardioTecTM
12-lead ECG Analysis

- 12-lead ECG to analyze I, II,III,aVR, aVL, aVF, V1-V6 and


display these waveforms on the same screen

- Two separate ECG cable to get accurate12-lead ECG


analysis

12-lead ECG waveform display

SpO2
- The first signal processing and sensor technology capable of accurately monitoring
physiology during motion artifact and low perfusion

Gold Standard of SpO2


- Identifies the venous blood and other noise, isolates them, and using proprietary
techniques, extracts the arterial signal

Mainstream CO2 & Sidestream CO2

Nomoline™
Adult/Pediatric
and Infant airway adapters
Advanced Plug-In Modules
Multi-GAS - Support 4-Channel IBP Electroencephalography EEG
Masimo Sidestream & Mainstream measurement measurement
Para-magnetic O2 sensors - Abbott / Edwards/ BD / Utah - Provides realtime waveform from 4
- Long life cycle IBP accessories can be channels / 8 channels / 16 channels
selected to monitoring ABP,
- Saving ongoing hospital cost - EEG module is designed for
PAP, CVP, ICP etc
continuous, real-time monitoring of
adult, paediatric and neonatal patients
in anaesthesia and intermediate/critical
care environments.

ICG - US BIoz®
Non-invasive Hemodynamic
- Impedance cardiograph for non-invasive continuous hemodynamic monitoring

- Micro-signal transmission through disposable electrode

- Measurement and display of ICG

- Blood volume and Blood Flow Velocity varies with heartbeat. DISQ® technology processes
impedance signal variation

- Variation of impedance applies to non-invasive Z MARC algorithm for acquiring SV, CO, SVR,
Contractility and TFC etc.

M797 & M757 modular monitors with option of transport monitor and separate modules for all vital signs

Calculation Screens
for Clinical use

Module Expansion Rack


(M797, M757)

Drug

Oxygenation Ventilation Kidney Hemodynamic


Feature M797 M777 M771

TFT Screen Size 17” 15” 19”

Touch Screen Operation ü ü ü


Type Modular Upgradable Modular

ECG Leads 3/5 3/5 3/5

12 Lead ECG Monitoring & Analysis (Optional) (Optional) (Optional)

ECG Review - Arrhythmia & ST Segment Analysis ü ü ü


SpO2 Self/ Masimo Self/ Masimo Self/ Masimo

Temp Channels 2 2 2

IBP Up to 4 (optional) Up to 4 (optional) Up to 4 (optional)

EtCO2 (Optional) (Optional) (Optional)


Anaesthetic Gas Module (CO , N O, HAL, ISO, ENF, DES, SEV, MAC)
2 2 (Optional) (Optional) (Optional)
Paramagnetic Oxygen Monitoring (Optional) (Optional) (Optional)
Cardiac Output (Optional) (Optional) (Optional)
Depth of Anaesthesia / BIS (Optional) (Optional) (Optional)
Respiratory Mechanics (RM) (Optional) x (Optional)
SVO2 (Optional) x (Optional)
ICG - Impedance Cardiography (Optional) x (Optional)
Neuromuscular Transmission (NMT) (Optional) x (Optional)
EEG (Optional) (Optional) (Optional)
Oxy CRG ü ü ü
Waveforms Up to 12 Up to 12 Up to 12

Waveform Recall Function ü ü ü


Drug Calculator ü ü ü
Graphics & Tabular Trends 120 hrs 120 hrs 120 hrs

Defibrillation Interface & Cautery Protection ü ü ü


Pacemaker Detection ü ü ü
Built-in Li-ion Battery Backup 2 hrs 4 hrs 2 hrs

Data Storage and Review 4 USB & SD Card 2 USB & SD Card 4 USB & SD Card

HL7 Compliant ü ü ü
Nurse Call Compatible ü ü ü
Connectivity with Central Wired/Wireless connectivity Wired/Wireless connectivity Wired/Wireless connectivity W
Monitoring System with Meditec CMS with Meditec CMS with Meditec CMS

In-built Thermal Printer (Optional) (Optional) (Optional)

Alarm System (Audible & Visual) 3 Level audio/ Visual alarm 3 Level audio/ Visual alarm 3 Level audio/ Visual alarm

Net Weight 11 Kg 4.8 Kg 6 Kg

Module Expansion Rack (Optional) x (Optional)

Wall Mount (Optional) (Optional) Standard

Mobile Trolley (Optional) (Optional) (Optional)


Bed Rail Mount (Optional) (Optional) (Optional)
Option for Transport Monitor ü x x
Bar Code Scanner (Optional) (Optional) (Optional)
M757 M752 M751 M747 M707
12.1” 12.1” 12.1” 12.1” 4.3”

ü ü ü (Optional) ü
Modular Modular Upgradable Upgradable Pre-Configured

3/5 3/5 3/5 3/5 3/5

(Optional) (Optional) (Optional) (Optional) x

ü ü ü ü ü
Self/ Masimo Self/ Masimo Self/ Masimo Self/ Masimo Self/ Masimo

2 2 2 2 2

Up to 4 (optional) Up to 2 (optional) Up to 4 (optional) Up to 2 (optional) x

(Optional) (Optional) (Optional) (Optional) (Optional)

(Optional) (Optional) x x

(Optional) (Optional) x x
Any One
(Optional) (Optional) x x

(Optional) (Optional) x x

(Optional) x x x x

(Optional) x x x x

(Optional) x x x x

(Optional) x x x x

(Optional) x (Optional) x x

ü ü ü x x

Up to 12 Up to 8 Up to 12 Up to 12 Up to 2

ü ü ü ü x

ü ü ü ü x

120 hrs 120 hrs 120 hrs 120 hrs 48 hrs

ü ü ü ü ü
ü ü ü ü ü
4 hrs 4 hrs 4 hrs 5 hrs 8 hrs

4 USB & SD Card 2 USB 2 USB & SD Card 1 USB x

ü ü ü ü x

ü x ü ü x

Wired/Wireless connectivity Wired/Wireless connectivity Wired/Wireless connectivity Wired/Wireless connectivity Wired/Wireless connectivity
with Meditec CMS with Meditec CMS with Meditec CMS with Meditec CMS with Meditec CMS

(Optional) (Optional) (Optional) (Optional) x

3 Level audio/ Visual alarm 3 Level audio/ Visual alarm 3 Level audio/ Visual alarm 3 Level audio/ Visual alarm 3 Level audio/ Visual alarm

5.9 Kg 3.4 Kg 4.8 Kg 3 Kg Light Weight 1.2 Kg

(Optional) (Optional) x x x

(Optional) (Optional) (Optional) (Optional) x

(Optional) (Optional) (Optional) (Optional) x

(Optional) (Optional) (Optional) (Optional) (Optional)

ü x x x x

(Optional) (Optional) (Optional) (Optional) (Optional)


Technical Specifications - Standard Parameters
Display NIBP
General Suitable Bedside monitors for Adult/Paediatric & Method Oscillometric
Parameters neonatal patients Mode Manual, Auto, Continuous
User selectable priority alarms - Red, Yellow, Measuring Interval in AUTO mode 1/2/3/4/5/10/15/30/60/90/
Orange color coded 120/240/480 Min
Sweep Speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s Continuous 5min, interval 5s
Various working Standard Monitoring Display, Large Font Intensive Measuring Type Systolic Pressure, Diastolic Pressure,
interface selectable Care Display, Trend Graph/ Monitoring Co- Mean Pressure
Display, Bed to Bed view Display (optional),
Cuff Pressure measuring Range 0–300 mmHg
OxyCRG Dynamic View Display, Drug Dose
Calculation Interface Pressure Resolution 1 mmHg
Trends Tabular & Graphical trends Mean error 3 mmHg
Events ECG, SpO2, NIBP with waveform & review Maximum Standard deviation 3 mmHg
Over pressure protection Dual Over pressure protection
ECG Measured unit mmHg/kPa selectable
Lead Mode 3 Leads (I, II, III), Measurement types Systolic, Diastolic, Mean
5 Leads (I, II, III, aVR, aVL, aVF, V) Systolic : 40-300 mmHg
Diastolic : 10-215 mmHg
12 Leads ((I, II, III, aVR, aVL, aVF, V1–V6)
Mean : 20-235 mmHg
Waveform Up to12 waveforms display on screen
Pressure range for Paediatrics Systolic : 20-235 mmHg
4 selectable plus 0.25, 0.5, 1, 2 cm/mV Diastolic : 10-150 mmHg
PACE Detection Automatic Mean : 20-165 mmHg
Defibrillation energy distributary Pressure range for Neonates Systolic : 10-235 mmHg
Input voltage range ±8mV, polarized voltage: ±500mV Diastolic : 10-100 mmHg
CMRR Diagnosis >100 dB (no 50Hz/60Hz software wave trap) Mean : 20-110 mmHg
Monitor >110 dB (has 50Hz/60Hz software wave trap)
Surgery >100dB (50Hz/60Hz software wave trap) SpO2
System noise <30µV p-p (RTI) Method Self / Masimo
HR Measuring and Alarm Range Measuring Range 1 – 100%
Adult/Paed 15 bpm – 300bpm Alarm Range 1 – 100%
Neo 15 bpm – 350bpm Resolution 1%
Accuracy ±1% or ±1bpm, which great Accuracy with
Resolution 1 bpm Adult / Paediatric with Low-perfusion 1 digit (70%–100% SpO2)
Undefined (0–70% SpO2)
Sensitivity > 200 μV P-P
Neonate 1 digit (70%–100% SpO2)
Differential Input Impedance ≥ 5 MΩ
Undefined (0–70% SpO2)
Electrode offset potential 300mVd.c. – 600mVd.c.
Pulse Rate Measuring and Alarm Range 20 – 300bpm
Patient leakage current < 10 uA
ECG Signal Range 6 mV (Vp-p).
Temp
ST Segment Monitoring Range
Measure and Alarm -2.0 – +2.0 mV Channel 2 Measuring Range 0 – 50°C
Sensor type YSI (B Series) and CF-FI Resolution 0.1°C
Respiration Accuracy 0.1°C (25°C–45°C), 0.2°C (0–25°C, 45° – 50°C)
Method Impedance between R-F (RA-LL), R-L (RA-LA)
Respiration Rate Measuring and Alarm Range:
Adult 0 rpm – 120 rpm Neo/Ped 0 rpm – 180 rpm
Resolution 1 rpm Accuracy 2 rpm
Gain Selection 0.25,0.5, 1, 2, 3, 4, 5

Technical Specifications - Optional Parameters


IBP CO2
Channel Up to 4 channel Channel Infra-red Absorption Technique
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring Mode Sidestream or Mainstream
Static Pressure Measuring Range (-)50 – +300 mmHg (up to 350 mmHg) Measuring Range
Static Pressure Accuracy ±2% or ±1mmHg whichever is higher CO2 0 – 150 mmHg AwRR 2 – 150 rpm
Dynamic Pressure Measuring Range (-)50 – +300 mmHg Unit mmHg, %, Kpa Resolution 1 mmHg, 0.1%, 0.1Kpa
Dynamic Pressure Accuracy 2 % or 1mmHg which bigger CO2 1mmHg InCO2 1mmHg
Measuring and Alarm Range Accuracy - AwRR ±1 rpm
ART 0 – 300 (mmHg) PA 6 – 120 (mmHg) Accuracy - CO2 2 mmHg, 0 – 40 mmHg
CVP/RAP/LAP/ICP (-)10 – 40 (mmHg) P1/P2 (-)50 – 300 (mmHg) Reading 5%, 41 – 70 mmHg
Resolution 1 (mmHg) Zero range 200 mmHg Alarm Delayed - AwRR 10 – 40 seconds
Response time <3 seconds, includes transport time, risetime
Resolution 1%
Technical Specifications - Optional Parameters
Cardiac Output (CO) Depth of Anaesthesia/ BIS
Method Thermodilution Technique Bispectral Index (BIS) 0 – 100
Measuring range - CO 0.1 – 20 L/min Electromyographic Strength (EMG) 30 – 80 dB (where 1µV2 = 40dB)
TB 23 – 43°C TI (-)1 – 27°C Signal Quality Index (SQI) 0 – 100%
Resolution - CO 0.1 L/min TB, TI 0.1°C Suppression Ratio (SR) 0 – 100%
Accuracy - CO 5% or 0.2 L/min TB 0.1°C Spectral Edge Frequency (SEF) 0.5 – 30.0Hz
TI 0.1°C Total Power 40 – 100dB (where 1µV2 = 40dB)
Output parameters CO, Hemodynamic Calculation Burst Count 0 – 30 (with an Extend Sensor only)
Alarm range 23 – 43°C EEG (Continuous, single channel real-time waveform(Standard) / 4 channel (Optional)
Noise (EEG Waveform) < 0.3 µV RMS (2.0 µV peak-to-
Neuromuscular Transmission (NMT) peak) : 0.25 Hz – 50 Hz
EEG Bandwidth 0.25 Hz – 100 Hz (-3 dB) ± 10%
Microprocessor-controlled
Stimulator Mode TOF, TOFS, PTC, 1Hz Twitch, 0.1Hz Twitch, Recorder
DBS 3.3 and 3.2 (double burst), Tetanic
Stimulation (burst), 5s-50Hz or 100Hz Built-in, direct thermal pixel array recorder up to 3 channel printing
Output (accuracy±5% of full scale value) 1, 2, 3 channel selectable
Surface Electrodes Constant current, 0-60mA(0-12/18µC) up to Print speed 25mm/s, 50mm/s
5Kohm, Monophasic, 200µs or 300µs pulse Paper width 50mm
width
Needle Electrodes Constant current, 0-6mA (0-0.24µC) up to Power Supply
5KOhm. Monophasic, 40µs pulse width
Acceleration Transducer Accuracy±5% of full scale value Input Voltage AC 100V–240V
Temp. Sensor Range 20.0-41.5°C (accuracy ±5°C) Input Frequency 50/60Hz

Multigas (AG) Environmental Conditions


Technology Side Stream or Main Stream Storage Temp (-) 10˚C – 40˚C
Gas CO2, N2O, Des, Iso, Hal, Sevo, Enf, O2 Humidity 15%–80%
Measuring Range Operational Temp 0˚C – 40˚C
CO2 0 – 10% O2 0 – 100% Humidity 15%–80%
N2O 0 – 100% AwRR 2 – 100 rpm Atmospheric Pressure 700kPa–1060kPa
Halothane 0 – 5% Isoflurane 0 – 5%
Enflurane 0 – 5% Sevoflurane 0 – 8%
Desflurane 0 – 18%
Other Up to 3 waveforms display, Agent mixture
detection MAC value display

Technical Specifications - Central Monitoring System


Standard Configuration Data
Processor Dual Core 720-hour full disclosure waveform review
Display 17"/19"/21"/24" TFT screen 1240-hour trend graphic review
Print HP printer 10,000 alarm record review
50,000 historical patient records
Features
Resolution 1280×1024 Recorder
Language English External thermal array
Waveform ECG, RESP, SpO2, NIBP, EtCO2, etc. Real-time recording, review recording and historical
Parameter HR, RR, ST, SpO2, PR, NIBP, TEMP, etc. Reports recording

Alarm Connection Mode


Alarms High and low limits alarm Complete solution for LAN, wireless LAN, and mixture networking
Arrhythmia alarm
Audible and visual alarm Power Supply
Input Voltage AC 100V–240V
Bedside Monitors
Input Frequency 50Hz ± 1Hz
Support maximum 128 bedside monitors
Display maximum 32 patient's information
Key monitoring interface, display 6 waveforms
Intellectualized Bi-directional Communication
Central Monitoring System
Bi-directional communication with Meditec Central Monitoring Station by wired or wireless connection

32 Beds display

Wave review and print preview Large font display

· Standard Network Interface: TCP/IP central monitoring · Data File Review: Large storage capacity of full monitoring
system, be able to observe full vital signs information of the information for easy review, analysis and statistics
patient
· Dual Screen: Support various data display methods and
· Full Disclosure Waveform Observation: Large screen display, various windows layout. It can display the waveform and
be able to observe 16 bedside monitors waveforms numeric information of ECG, SpO2, RESP, NIBP, IBP, CO2, etc.
simultaneously. Selectable Dual-screen display. The key bedside monitoring function provides more detail
information to the doctor.
· Bi-directional Communication: Unique Bi-directional
communication function realize the mutual control of central · Operating System: User-friendly central monitoring software
monitor and bedside monitors built on Windows platform. Advanced information integration
technology to realize the concentration management of all
· Large Storage Capacity: 720-hour full disclosure waveform parameters. Full digital transmission to ensure the
review, 1240-hour trend graph review, 1000 alarm records communication accurate and reliable.
review. 50,000 patient historical data. All the information can
be stored in disk. · Stable Internet Connection: Standard configuration for 8
bedside monitors, support maximum 128 units
#55000375R2 Dt. 01.01.2018

Meditec International England Limited


8, Pinner View, Harrow, Middx,
HA1 4QA, United Kingdom
Tel: +44 203 6423808
E-mail : [email protected] *In view of continued product improvement Meditec International England Limited
reserves the right to make changes in the equipment which may affect the information
Website : www.meditecengland.co.uk contained in this leaflet without giving any prior notice. Pictures are representative,
accessories are optional and may vary at the time of supply.