g Cooling method: TEFC – Totally enclosed g Terminal boxes: Steel welded terminal
frame 560 (8806/10) 4, 6, 8, 10 and 12 pole. g Sleeve bearings for all frame sizes
g Insulated non-drive endshield bearing g Insulating brush kit for drive end shaft
g Shaft locking device for bearings protection g Voltage surge protection: Lightning
1200
(kW)
1200
输出功率(kW)
输出功率(kW)
Output
800 800
g Signal transducer
600 600
g Special shaft dimensions
400 400
g Tacogenerator
200 200
g Non-reverse ratchet
0 0
g Base: rail, sliding base, extended feet,
2P 4P 6P 8P 2P 4P 6P 8P
极数 Poles Poles
极数 rebuilt feet, anchorage plate
315 355 400 450 500 560 315 355 400 450 500 560
Notes: Only 450 seats are available for 2-pole motors, 500,560 and 630 seats require advance consultation. Larger output power needs to be consulted in advance.
2 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 3
www.weg.net www.weg.net
With the optimization of the frame’s structural design, the Motors may be fitted with sleeve bearings as an optional
intent was the best equation between mechanical rigidity and feature in direct coupling applications. Sleeve bearings require
thermal dissipation possible for enclosures, thereby reducing less maintenance due to the fact that the lubrication intervals
motor vibration and increasing lifetime. are up to three times longer than the lubrication intervals of
The HGF motor frames consist of a single piece of high conventional bearings, and specially because they present a
strength cast iron. External and internal fins, in conjunction lifetime similar or longer than that the motor itself.
with the fan and fan cover, provide the maximum heat The sleeve bearings are also outstanding for their very low
dissipation possible for a self-ventilated motor, thus enabling operating noise level and for supporting higher speed levels
increased levels of rated power per frame size and avoiding when compared to conventional bearings.
the overheating of the motor.
The gray cast iron FC-200 produced by WEG foundries is the
material recommended by the Standards for explosion proof
motors and it provides the HGF motors with higher strength
and durability.
Terminal box Fan cover
The main and accessories terminals are supplied inside two different The fan cover was designed to direct airflow over the entire
terminal boxes. Through its oversized dimensions and versatility, the frame with minimal recirculation in the motor interior, allowing
motors will offer easy connection, and can be supplied according to maximum heat exchange and resulting in a cooler motor.
the customer’s preference, with flying leads, terminal pins or screws This innovation in the cooling system offers lower noise levels,
(for high voltage motors), etc. Terminal boxes can be rotated in 90°. with reductions of up to 7 dB(A), in addition to the higher
Under demand, the motors can be supplied with steel constructed mechanical strength and optimal air flow.
terminal boxes, and, with a second main terminal box for Y Additional noise supressors are available as special feature.
connection with accessible neutral.
The design of the ventilation system of the HGF line provides mechanical strength and optimum air flow, allowing reductions in
the sound pressure level of up to 7 dB (A), thus increasing the reliability and longevity of the motor. The tables below show the
sound pressure levels for frames sizes 315 to 400.
90 90
80 80
75 75
70 70
315 355 400 315 355 400
(5006/7/8T and (5807/8/9T and (6806/7/8T and (5006/7/8T and (5807/8/9T and (6806/7/8T and
5009/10/11T) 5810/11/12T) 6809/10/11T) 5009/10/11T) 5810/11/12T) 6809/10/11T)
4 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 5
www.weg.net www.weg.net
One of the greatest benefits offered by the HGF motors is the flexibility. Due to its production process, WEG can tailor-make This line was developed for hazardous areas where explosive
these motors according to customer specifications. This makes the HGF the ideal product drop-in replacement motors in any atmospheres may occur (as standard: an explosive atmosphere
kind of application. This versatility is exemplified by the availability of several mounting configuration and characteristics such as will probably not be present under normal operating conditions
special built bases (rails, sliding base, anchorage plate, etc). and, if any, this will be for short periods of time, that is, an
This flexibility on mounting allows the construction of these motors in higher degrees of protection, up to IP66W. This degree of explosive atmosphere may be present accidentally).
protection is suitable for the most aggressive environments, such as Siderurgy Industries applications, where SO2 gases, This type of protection is applied to electrical equipment which
vapors, solid contaminating agents, high humidity, alkalis, and solvent drips are constantly present. does not cause ignition of an explosive atmosphere under normal
HGF motors can be designed to be driven by frequency inverters, offering the maximum in control and precision, two decisive operating conditions.
items for the Sugar and Ethanol Industry. Special applications such as cane shredders and grinders require speed variation in The IEC Ex nA HGF motors have been certified by BASEEFA,
tough conditions. HGF motors meet this requirements, with higher degrees of protections available and high starting torques. according to ATEX Directive 94/9/EC and are protected for
These motors are also used and sugar mills and alcohol distilleries for fans, exhausters and centrifugal pumps. Hazardous operation in hazardous areas classified as Zone 2, Group II,
locations can also be served with our Ex-nA HGF Line. Temperature Class T3.
Precision and reliability are also essential in the Pulp and Paper Industry. In the coiling machine, for example, one of the most HGF NEMA motors meet the requirements of the standard NEC
fragile applications, an accurate speed control and mechanical strength are demanded. As this is a critical part of the process, referring to hazardous areas classified as Class I Division 2,
the HGF motors are widely used on it, offering low maintenance and outstanding performance levels. For the several other motor Groups B, C and D, Temperature Code T3. Optionally, these
applications in this industry, the motors can be supplied with special painting plans and stainless steel screws, resulting in longer motors can be designed to operate in areas classified as Class II,
lifetimes in the aggressive and corrosive ambient conditions present in the industries. Groups F and G. HGF NEMA motors are CSA certified.
Widely used in Oil & Gas Industry, Pulp & Paper Industry,
Sugar & Ethanol Industry, etc.
NEMA HGF Vertical Line
Low or High Thrust Applications
Vertical motors are used in all kinds of industries and HGF API 541 Line
applications. The application can be highlighted in the Water
and Wastewater Industry, where HGF motors are applied to The American Petroleum Institute, known as API, is the leading
large vertical pumps, mixers, agitators, cooling towers, etc. trade association for the U.S. segment of Petroleum and Natural
Through sophisticated tools for finite elements calculation, Gas, representing approximately 400 industries involved in
WEG has designed the new HGF motors for applications with production, refining, distribution and various other aspects of the
high thrust, making them ideal for vertical applications. oil industry.
To ensure that each motor has an excellent thermal and airflow The HGF API 541 Line was specifically developed to meet the
performance, tests were performed to determinate the most standard determined by the API, called the API 541, for electric
favorable design which maintains lower bearing temperatures. motors which will operate in the environments of Oil & Gas Industry.
The result is a simple assembly that meets the rigid The HGF API 541 line strictly complies with the requirements of
requirements of high thrust vertical application. the standard, widely used in petrochemical industries not only in
America but around the world, and is highly utilized in the Middle
HGF Mining Line
East, the largest world oil producing region.
lower rotor temperature and higher speed performance. The thermochemically treated low electrical loss
magnetic steel lamination produces high operating efficiency and enhanced reliability. Copper bar rotors
Our die-cast aluminum rotor has lower inertia, higher starting torque, excellent mechanical rigidity,
These frames are designed with finite element analysis
to improve mechanical strength, heat dissipation and
provide high pressure values. WEG produces the world’s
WEG has developed a special insulation system to withstand voltage surges and
transients in modern applications. In addition, all low-voltage motors are equipped with
2. Classification................................................................................................................................................................................................. 10
voltage resistant lines and insulation suitable for frequency conversion applications.
noise electric motors. Our fan is designed to ensure a
low motor temperature rise, thus minimizing winding
4. Structural details........................................................................................................................................................................................... 11
4.1 Shell protection........................................................................................................................................................................................ 11
Fan cover
With excellent mechanical stiffness, corrosion
4.4 Stator winding......................................................................................................................................................................................... 12
4.5 Nameplate.............................................................................................................................................................................................. 13
4.5.1 Main nameplate.............................................................................................................................................................................. 13
Frame
4.6 Cooling system, noise and vibration levels.............................................................................................................................................. 13
4.6.1 Cooling system............................................................................................................................................................................... 13
4.6.2 Noise level...................................................................................................................................................................................... 13
Fan
Stator
4.7 Shafts, bearings and loading.................................................................................................................................................................. 15
electrical data and bearing lubrication information.
4.7.1 Shaft............................................................................................................................................................................................... 15
4.7.2 Bearing........................................................................................................................................................................................... 15
4.7.2.1 Axial bearing configuration................................................................................................................................................... 16
tion direction and warning nameplate.
Rotor
4.7.3.2 Lubrication - Vertical installation of high axial thrust............................................................................................................ 18
Auxiliary nameplate
4.9.2 Painting..........................................................................................................................................................................................20
discharged from the chassis.
4.10 Voltage/Frequency................................................................................................................................................................................21
4.11 Ambient X Insulation..............................................................................................................................................................................21
4.12 Motor protection....................................................................................................................................................................................21
and minimize fatigue, thus achieving superior performance.
4.12.1 PT-100..........................................................................................................................................................................................21
4.12.2 Thermistor(PTC).......................................................................................................................................................................20
4.12.3 Bimetallic thermal protector..........................................................................................................................................................20
Drain
Provide a connection to accommodate motor voltage and lead volume.
Shaft
9. Service..........................................................................................................................................................................................................39
Bearing
Cover
Seal
8 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 9
www.weg.net www.weg.net
2. Classification
HGF series motors are named according to the following rules:
IM B35 IM V15
IEC: Motors with frame size 400 have two length casings, each casing has 3 sets of foot holes, respectively: IM 2001 IM 2011
The length of the case with frame size 450 and above is unique. Each case has 5 foot holes (L/A/B/C/D) of different lengths.
These enclosures are represented as:
HGF450, HGF500, HGF560, HGF630
IM B5 IM V1
IM 3001 IM 3011
3. Standard
HGF series motors meet the requirements and specifications of the latest version of the following standards:
Title Standard
IEC Market (other than Brazil)
Rotating electrical machines, rating and performance IEC EN 60034-1
Rotating electrical machines, Methods for determining losses and efficiency IEC 60034-2
Dimensions and output series for rotating electrical machines IEC 60072-1 and 2
Terminal markings and direction of rotation for rotating electrical machines IEC EN 60034-8
Rotating electrical machines, Symbols for types of construction and erection IEC EN 60034-7
Built-in thermal protection IEC 60034-11
Rotating electrical machines, methods of cooling IEC EN 60034-6 The base and end cover are made of FC-200 cast iron. The heat sink distributed on the outer surface of the base not only enhan-
Rotating electrical machines, degrees of protection IEC EN 60034-5 ces the mechanical strength of the base, but also optimizes the heat dissipation effect. The base has integrated motor foot holes,
Rotating electrical machines, mechanical vibrations IEC 60034-14
Rotating electrical machines, noise limits (1kW up to 5500kW) IEC EN 60034-9 which makes the overall structure of the base more solid. The bottom of the base is equipped with a plastic drain hole. The
Rotating electrical machines, starting performance of induction cage motors up to 660V, 50Hz IEC EN 60034-12
IEC standard voltages IEC 60038 motor uses different positions of drain holes due to horizontal or vertical installation, as shown in the figure below:
Brazilian Market
Electric Rotating Machines - Induction Motors - Part 1: AC NBR 17094-1
Rotating Electrical Machines - Part 1 Three-Phase Induction Motors – Test NBR 5383-1
Rotating Electrical Machines - Induction Motors - Marking Cables and Terminals Rotation Direction NBR 15367
Rotating Electrical Machines - Dimensions and power series for rotating electrical - standardization - Part 1:
NBR15623-1
Appointment of carcasses between 56-400 and between flanges and flanges between 55-1080
Rotating Electrical Machines - Dimensions and power series for rotating electrical - standardization - Part 2:
NBR15623-2
Appointment of carcasses between 355-1000 and between flanges and flanges between 1180-2360
Rotating Electrical Machines - Noise Limits NBR 7565
Rotating Electrical Machines - Degrees of protection provided by nclosures NBR IEC 60034-5
Rotating Electrical Machines - Classification of Mounts and Mounting Positions NBR 5031
NEMA Markets
Motors and Generators NEMA MG1
Non-Sparking Motors
Brazil –
Explosive Atmospheres Part 0: equipment – General Requirements ABNT NBR IEC 60079-0
Electrical Equipment for Explosive Atmospheres – Part 15: Construction, testing and marking of electrical apparatus
–
with type of protection "n"
ABNT NBR IEC 60079-15 –
IEC (other than Brazil)
Electrical Apparatus for Explosive Gas Atmospheres–Part 0:General Requirements IEC 60079-0
Electrical Apparatus for Explosive Gas Atmospheres–Part 15: Type of Protection “N” IEC 60079-15
API 541 Motors
Form-wound squirrel cage induction motors – 500 horsepower and larger API 541
Figure 1-Position of the drain hole of HGF motor installed horizontally and vertically
Fastening bolts and junction box mounting bolts are 8.8 (ISSO 898/1) grade, zinc-plated. API 541 HGF motor is equipped with
Table 1-Standards that must be observed in motor design
SAE316 stainless steel fastening bolts and junction box mounting bolts.
10 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 11
www.weg.net www.weg.net
4.2 Fan cover motor is equipped with 2 PT100s for temperature detection. 4.5.3 Warning nameplate
Each motor is equipped with a space heating system.
HGF horizontal and vertical mounting motors with frame sizes The windings of low-voltage motors are wound with scattered HGF motors with rated voltage higher than 1kV are equipped
ranging from IEC 315C/D/E to 400C/D/E and using anti-friction wires. For HGF motors with frame sizes from 315C/D/E to 450, with safety nameplate, and the junction box cover is marked
bearings and without forced cooling are equipped with fan the winding insulation dipping paint adopts continuous drip with high voltage warning.
covers, as shown in the figure. dipping process. High voltage motors use shaped coil windings
and are impregnated by a vacuum pressure impregnation (VPI)
system.
4.5 Nameplate
Figure 5-Standard HGF main junction box In accordance with the requirements of IEC 60034-1, HGF mo-
tors provide nameplates with performance data. At the same
The terminal leads from the winding are introduced into two
time provide auxiliary component nameplate. The nameplate
terminal boxes: a main terminal box for connecting the power
is made of SAE 304 stainless steel, and the content of the
supply; an auxiliary terminal box, which contains two parts,
nameplate is engraved by laser. The motor serial number and
which are respectively used for connecting the PT100 and the
production date are marked on the main nameplate. All name-
space heating belt.
Figure 2-HGF IEC 315L/A/B to 400C/D/E motors plates are fastened and installed on cast iron parts (such as
base or auxiliary junction box cover) by bolts.
Figure 13-Example of Nameplate-High Voltage Warning Nameplate
Grounding blocks are installed on the feet on both sides of the
4.5.1 Main nameplate
motor. A grounding block is also installed in the junction box. 4.6 Cooling system, noise and vibration levels
Non-sparking explosion-proof motors and API 541 motors are
equipped with grounding strips to connect the junction box
4.6.1 Cooling system
and the frame, as shown in the figure below.
Figure 6-The auxiliary junction box According to the IEC 60034-6 standard, the cooling method
of HGF motor is totally enclosed self-fan cooling (IC411). HGF
The low-voltage HGF motor provides 6 lead wires, which can motors can also use forced cooling (IC416), fanless self-coo-
be started directly from the grid power supply or using a star- Figure 9-Example of a nameplate-main nameplate ling (no external cooling) (TENV) and fanless self-cooling (with
delta start. For ease of installation, all leads are connected to external cooling) (TEAO) and other cooling methods. For more
terminal blocks. information about IC416, please refer to the “Variable Frequen-
4.5.2 Auxiliary nameplate cy Drive” section.
12 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 13
www.weg.net www.weg.net
Frame Sound Pressure Levels dB (A) to 60 Hz threaded hole is shown in the figure below. Maximum relative shaft displacement
Synchronous speed (rpm)
IEC NEMA 2 poles 4 poles6 poles8 poles If necessary, the vibration sensor can be provided with the mo- (peak to peak)
315 C/D/E 5009/10/11T 79 79 77 75 tor. 1801-3600 0.0020" (50μm)
355 C/D/E 5810/11/12T 86 83 81 79 1201-1800 0.0028" (70μm)
400L/A/B & 400 C/D/E 6806/7/8T & 6809/10/11T 89 83 81 79 ≤1200 0.0030" (75μm)
450 7006/10 92 92 88 82
500 8006/10 92 92 88 85 4.7 Shafts, bearings and loading
560 8806/10 - 92 92 85
630 9606/10 - 92 92 85
4.7.1 Shafts
The above sound pressure level data is measured by the motor
under no-load conditions. According to the IEC 60034-9 stan-
dard, the sound pressure level increment of the motor under full The standard motor shaft material is AISI4140, and the size
meets the requirements of the IEC60072 standard. In order to
load is shown in the table below. facilitate the maintenance of the motor and installation of the
Shaft Height H(mm) 2 poles 4 poles 6 poles 8 poles coupling, all HGF motor shafts have a threaded center hole (in
H=315 2 3 5 6 Figure 14 - Threaded hole location for vibration monitoring
accordance with DIN332). You can check the corresponding Figure 16-HGF vertical motor with high thrust load
H≥355 2 2 4 5
4.6.4 Axial displacement limit center hole size in the mechanical data part of this sample.
HGF series motors, grease-lubricated bearings, standard bea-
Note: ring life is 40,000 hours; vertical high-thrust load oil-lubricated
1. These values apply
to both 50Hz and 60Hz. According to the IEC 60034-14 standard, it is recommended The standard shaft motor is equipped with a B key (other key
bearings, standard bearing life is 12,000 hours. At the same
2. The sound pressure level is measured under sinusoidal to measure shaft displacement only for motors with a speed types under inquiry). To meet the special needs of customers,
time, HGF motors can calculate different bearing life according
conditions. The sound pressure level increment of the VFD exceeding 1200 rpm and a rated power exceeding 1000 kW, HGF motors can also be designed with special shaft sizes.
to special requirements.
varies with the switching frequency. In any case, the maximum equipped with sliding bearings.
value of the increment shall not exceed 11dB(A). HGF motor can also be designed with double shaft extension. Both the drive end and the non-drive end of the HGF motor
The design of the motor is suitable for installing proximity According to application needs, HGF motor can choose other can be equipped with sliding bearings. Sliding bearings rarely
sensors. API541 motors are equipped with this design. For shaft materials. You can check the corresponding biaxial ex-
4.6.3 Vibration level require maintenance when they are directly connected under
other motor series, please contact WEG. tension dimensions in the mechanical data part of this sample. harsh operating conditions.
The vibration level of the motor is closely related to its installa- 4.7.2 Bearings
tion. Therefore, it is recommended to check the vibration level The sensor reading is affected by mechanical factors and
during routine maintenance. magnetic interference of the shaft, and is generally designated
as jitter. The NEMA-MG1 standard stipulates that the runout For HGF motors, when the frame size does not exceed IEC500,
should be measured at a low speed (100 to 400rpm), because use anti-friction open ball bearings with a clearance of C3.
In order to evaluate the vibration of the motor itself, it must be When the frame size is IEC560 and 630, one roller bearing and
measured according to the test procedure required by the IEC the effect of unbalanced force can be ignored in this case.
one ball bearing are used at the non-drive end.
60034-14 standard when the motor is not connected to other
equipment. Considering electrical and mechanical runout, the vibration of
the shaft of a standard motor equipped with sliding bearings The grease-lubricated bearings used in HGF motors are equip-
shall not exceed the following limits: ped with an efficient grease retaining ring system to achieve
The motor vibration intensity allowed by the IEC 60034-14 high-efficiency lubrication while ensuring a low bearing tempe-
standard is divided into Class A and Class B, as shown in the Maximum displacement Runout (μm)
Vibration Level Speed range (rpm) rature. The bearing is equipped with a PT100 temperature sen-
relative to the shaft (μm) (peak to peak)
following table: sor, which can continuously monitor the bearing temperature
A >1800 65 16
Figure 17-Sliding bearing
Vibration Level Mounting Displacement μm Velocity mm/s Acceleration m/s2 ≤1800 90 23 during the operation of the motor.
A Free suspension 45 2.8 4.4 B >1800 50 12.5
Note: According to special requirements, 2-pole and vertical
Rigid mounting 37 2.3 3.6 ≤1800 65 16 All HGF series motors use bearings with C3 clearance, but be-
B Free suspension 29 1.8 2.8 installation (standard thrust) motors with frame size IEC400C/
Rigid mounting 24 1.5 2.4 arings with C4 clearance can also be used for special needs. D/E can be provided.
According to the NEMA MG1 standard, only non-contact
proximity sensors can measure the vibration limit value of the
Vibration level B is suitable for motors with special vibration Horizontally mounted motors with high radial load can be
motor shaft. The vibration limit values for standard and special
requirements. equipped with NU series roller bearings, as shown in the fol-
motors are given below. In order to obtain good measurement
All rotors have half-keys for dynamic balance, and the standard lowing table:
results, the peak-to-peak value of the shaft jitter should not
motors conform to class A (3). Frame Roller bearing
exceed 6.4μm (peak-to-peak value 0.0005 inches), or 25% of Poles
Optional grade B is optional for special requirements. IEC NEMA DE
the vibration displacement limit value, whichever is greater.
315 C/D/E 5009/10/11T 4-8 NU320
(3) API 541 motor conforms to vibration level B.
355 C/D/E 5810/11/12T 4-8 NU322
Standard motor limit value 400L/A/B & 400 C/D/E 6806/7/8T & 6809/10/11T 4-8 NU324
NEMA Vibration level 450 7006/10 4-8 NU328
Considering electrical and mechanical runout, the vibration of 500 8006/10 4-8 NU330
Synchronous speed Rotational Frenquency Limiting vibration speed the shaft of a standard motor equipped with sliding bearings Figure 15-Ball bearing cap design 560 & 630 8806/10 & 9606/10 Under request
zero-peak shall not exceed the following limits:
[rpm] [Hz]
[pol./s] [mm/s]
Maximum relative shaft displacement Vertical HGF motors have two different bearing configurations:
3600 60 0.15 3.8 Synchronous speed (rpm)
(peak to peak) low-thrust standard, driven by the anti-friction ball bearing at The standard bearing size can be identified by the frame
1800 30 0.15 3.8
1801-3600 0.0028" (70μm)
the drive end and the angular contact ball bearing at the non- number in the table below.
1200 20 0.15 3.8
≤1800 0.0035" (90μm)
900 15 0.12 3.0 drive end; other high-thrust models are composed of a grease-
720 12 0.09 2.3
Special motor limit value lubricated ball bearing at the drive end and an oil-lubricated
600 10 0.08 2.0 spherical roller thrust bearing at the non-drive end, and an oil
Considering electrical and mechanical runout, the vibration of bath with natural cooling system is provided.
In order to monitor the vibration status, the HGF motor end co-
ver is equipped with 3 M8 threaded holes, which can be used the shaft of a rigidly mounted special motor equipped with sli-
to install vibration sensors. In addition, users can purchase ding bearings shall not exceed the following limits:
threaded sockets according to their needs. The position of the
14 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 15
www.weg.net www.weg.net
16 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 17
www.weg.net www.weg.net
4.7.3.2 Lubrication - Vertical installation of high axial thrust 60Hz-Fr (Kn) 4.7.4.3.1 Normal thrusting
Frame 2P 4P 6P 8P
Bearing vertical motor to withstand higher axial thrust, resulting in higher bearing temperature, the need for oil lubrication, in order IEC NEMA L/2 L L/2 L L/2 L L/2 L
Under normal thrust conditions, the angular contact ball bea-
to ensure the appropriate oil film and heat dissipation.WEG motor standard non - drive end bearings are designed for oil bath 315C/D/E 5009/10/11T 2 2 5 5 6 5 7 6
355C/D/E 5810/11/12T 1 1 5 4 6 4 7 6 ring is installed at the non-drive end, and the maximum axial
lubrication systems.
400L/A/B & 6806/7/8 & thrust can be borne is shown in the following table
The following table gives information on the type of lubricant used on the bearing and the specific lubrication period when axial 400C/D/E 6809/10/11T
5 5 6 6 8 6
- Maximum Axial Thrust in the Shaft End
loads are taken into account.Grease - lubricated drive end bearings follow the same recommendation as in the above item as they 450 7006/10 7 6 8 8 9 9 Frame Momentaneous
only have radial guidance function. 500 8006/10 7 6 9 8 10 10 Poles Pulling (kN)
IEC NEMA pushing (kN)
Relubrication interval Relubrication Maximum radial load of rolling bearing Is assumed to be no 2 * *
Frame Quantity of oil Lubricant 4 8 5
Poles D.E. bearing 50Hz 60Hz N.D.E. bearing interval for 50Hz Lubricant axial load of motor (50&60Hz) 315C/D/E 5009/10/11T
(L) specification 6 8 5
IEC NEMA (h) (h) and 60Hz 50Hz-Fr (Kn) 8 8 6
4 4200 3200 Frame 4P 6P 8P 2 * *
315C/D/E 5009/10/11T 6 6320 29230 20 IEC NEMA L/2 L L/2 L L/2 L 4 9 6
4500 4500 355C/D/E 5810/11/12T
8 315C/D/E 5009/10/11T 25 12 25 12 25 12 6 9 7
4 3600 2700 355C/D/E 5810/11/12T 28 14 18 7 17 7 8 9 7
355C/D/E 5810/11/12T 6 6322 29230 26 Mineral oil ISO 400L/A/B & 6806/7/8 & 2 * *
4500 4500 FUCHS Renolin 32 16 20 8 17 8
8 400C/D/E 6809/10/11T 400L/A/B & 6806/7/8 & 4 10 7
VG150 with
8000 DTA 40 / Mobil 450 7006/10 35 23 35 23 25 10 400C/D/E 6809/10/11T 6 10 7,5
4 3200 2300 defoaming and
400L/A/B & 6806/7/8 & SHC 629 500 8006/10 33 21 38 14 37 14 8 10 7,5
6 6324 4500 4300 29230 27 anti-oxidant 560 8806/10 27 25 29 27 29 26 2 * *
400C/D/E 6809/10/11T
8 4500 4500 630 9606/10 14 7 14 7 20 10 4 8 7
4 2400 1700 450 7006/10
6 8 7
60Hz-Fr (Kn) 8 8 7
450 7006/10 6 6328 4100 3500 29230 45
Frame 4P 6P 8P 4 6 5
8 4500 4500 IEC NEMA L/2 L L/2 L L/2 L 500 8006/10 6 6 5
315C/D/E 5009/10/11T 25 12 25 12 25 12 8 6 5
4.7.3.3 Lubricated plain bearings 355C/D/E 5810/11/12T 30 15 20 8 19 7
400L/A/B & 6806/7/8 &
32 16 23 12 19 8 *Consult WEG
400C/D/E 6809/10/11T
HGF motor can be selected using sliding bearings. When the motor is used correctly and the recommended lubricant is used, 450 7006/10 33 22 24 9 24 9
sliding bearings require less maintenance, a longer lubrication period, and a longer bearing life. The table below shows available 500 8006/10 26 17 21 17 21 17 4.7.4.3.2 High thrusting
base Numbers, lubricating oil type and lubricating oil dosage information, and recommended lubrication cycles. 560 8806/10 24 23 26 25 26 24
630 9606/10 28 18 22 11 36 18 High-axial thrust bearings can be used for motors with speeds
Frame 50 & 60 Hz Maximum radial load value of roller bearing assume no axial up to 1800 RPM (4-60Hz). Oil bath lubrication system is simple
Poles Bearings Oil Qty (L) Lub. Lubricant spec.
IEC NEMA (h) and robust. The non - drive - end bearings lubricated in this
315C/D/E 5009/10/11T load of motor (50&60Hz) way have good heat dissipation performance and low bearing
355C/D/E 5810/11/12T FUCHS Renolin Mineral oil ISO VG32 with Note: temperature under adverse service conditions. For this appli-
2 9-80 8000 2.8
400L/A/B & 400C/D/E 6806/7/8 & 6809/10/11T DTA 10 antifoaming and antioxidant 1. Roller bearings require minimum radial load for normal cation, the standard bearing life is 12,000 hours. In this case,
450 7006/10 operation. Direct connections are not recommended. anti-rotation ratchet system can be optional. The table below
Sleeve Bearings 315C/D/E 5009/10/11T 9-90 2. Application analysis of 50 Hz motor with output higher than
2.8 shows the maximum allowable axial thrust for each frame size.
355C/D/E 5810/11/12T 9-100 590kW 4P, 515kW6P and 400KW8P.
FUCHS Renolin Mineral oil ISO VG46 with
4,6 & 8 400L/A/B & 400C/D/E 6806/7/8 & 6809/10/11T 11-110 8000 3. Application analysis of 60 Hz motor with output higher than
DTA 15 antifoaming and antioxidant
450 7006/10 11-125 4.7 Maximum load for continuous tension Minimum
700KW 4P, 560kW6P and 480kW8P. Frame 1800 RPM 1200 RPM 900 RPM
500 8006/10 load
IEC NEMA kN lbf kN lbf kN lbf kN lbf
4.7.4 Maximum available shaft load 4.7.4.2 Axial thrusting - Horizontal mounting 315C/D/E 5009/10/11T 45 10200 59 13200 65 14600 4.23 950
4.7.4.1 Radial load 355C/D/E 5810/11/12T 50 11200 57 12800 62 13900 5.34 1200
400L/A/B & 6806/7/8 &
The following table lists the maximum axial thrust (kN) for hori- 43 9600 51 11300 54 12200
The following table shows the maximum available radial and 400C/D/E 6809/10/11T 7.56 1700
The maximum load shown in the table below takes into ac- zontal mounting of motor shaft ends. 450 7006/10 42 9400 47 10500 51 11400
axial loads in standard configurations. This table takes into
count the load applied by the shaft overhang (L) and half of the Maximum Axial Thrust in the Shaft End
account the bearing’s service life of 40,000 hours. The ma- shaft overhang (L/ 2). Horizontal mounting - The maximum instantaneous upward thrust is 30% of the maximum pulling
ximum radial load values in the table below assume no axial Frame force
Horizontal mounting (Ball bearings)
Poles - All bearings are self-cooled
load on the motor. In addition, the maximum axial load value IEC NEMA
Pulling or Pushing
(Kn) - Consult WEG for higher load/speed requirements
assumes no radial load on the motor. For bearing service life - Motor running with lower downward thrust has higher vibration
2 2
when the motor is under both axial and radial loads, please 4 5
contact WEG. 315C/D/E 5009/10/11T
6 6 In order to improve the bearing life (12000h), the actual axial
8 7 thrust is the maximum axial thrust divided by the corresponding
2 1,7 reduction factor, as shown in the table below:
When determining the maximum load, the following conside- 4 6
rations should be taken into account: 355C/D/E 5810/11/12T
6 7
8 7,5 L 10h useful life Life in years Adjustment factor
1. Normal operating conditions; 12000 1.4 1.00
2 1,7
2. AISI material axis; 400L/A/B & 6806/7/8 & 18000 2.0 1.15
4 6
3.2 Pole motor: parabolic torque load (such as fan, superchar- 400C/D/E 6809/10/11T 6 7 22000 2.5 1.24
26000 3.0 1.32
ger, centrifugal pump, centrifugal compressor, mixer, etc.); 8 7,5
Figure 21 - Radial load at shaft end
2 1 35000 4.0 1.47
4. Non-2-pole motor: constant torque load (reciprocating 40000 4.5 1.55
4 5
compressor, elevator, crane, reciprocating pump, conveyor 50Hz-Fr (Kn) 450 7006/10 44000 5.0 1.61
6 6
belt, etc.); Frame 2P 4P 6P 8P 8 7 53000 6.0 1.72
4 5 62000 7.0 1.83
5. If you have any questions about load torque requirements, IEC NEMA L/2 L L/2 L L/2 L L/2 L 70000 8.0 1.92
315C/D/E 5009/10/11T 2 2 6 5 6 6 7 7 500 8006/10 6 6
please contact the NEAREST WEG office; 8 7 75000 8.5 1.98
6. These values take into account the friction resistant ball 355C/D/E 5810/11/12T 1 1 5 5 7 6 7 7 88000 10.0 2.11
400L/A/B & 6806/7/8 & 100000 11.4 2.22
bearings and the standard for horizontal mounting motors of 400C/D/E 6809/10/11T
6 5 7 7 8 8 4.7.4.3 Axial thrusting - vertical installation
the frame size up to IEC500. -
450 7006/10 7 7 9 8 9 9 When special bearing life or higher axial loads are required,
500 8006/10 8 7 9 9 10 9 HGF vertical mounting motors can be divided into two types: Please contact WEG.
normal thrust and high thrust. This classification is based on
the maximum available axial load at the motor shaft end.
18 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 19
www.weg.net www.weg.net
4.8 Installation directions to the machine without harmful effects. 4.10 Voltage/Frequency standard, the ambient temperature considered in the design
The lowest position of the motor stand is provided with a cock is 40°C, and the generally used insulation class is Class F
The installation of HGF follows the IEC60034-7 standard. The drain hole, the specific position depends on its installation po- According to IEC60034-1 (IEC Market), the fluctuation of vol- (155°C)-see the table below.
figure below shows the basic and other installation types. sition. tage and frequency can be divided into Area A and Area B, as Thermal Gap 25oC
Other protection levels shown below. Hottest - coldest point 10oC
155oC material class limit
HGF motors can be designed for the following protection le-
Voltage
Temperature Rise 80K
Ambient temoerature 40oC
vels: Zone A
• For better outdoor protection, use an IP55W In order to ensure the long service life and safe operation of
• For better water resistance, use IP56 the motor, it is necessary to avoid overheating of the motor.
• For better dust protection, use IP65 Therefore, the most common protection device for the motor
• For better dust and water resistance, use IP66 Frequency
is the heat sensitive device.
Two three-wire PT100 are standard for each phase winding
4.9.2 Painting Standard
Features of HGF motor, and one three-wire PT100 is standard for each
bearing.
212P Paint scheme for HGF motor (WEG code)
Zone B (external to Zone A)
4.12.1 PT-100
According to ASTMB117/03, the spray scheme is subject to
at least 3000 hours of salt spray testing and can be exposed Figure 23 - Motor rated voltage and frequency limits
In some materials (such as platinum, nickel, or copper), the re-
to high humidity indoor and outdoor harsh Marine and indus- sistance changes as the temperature changes. The tempera-
The motor must be suitable for continuous operation in zone A
trial Marine environments.The spray scheme is used in the ture measuring element is based on this for temperature mo-
and achieve its main performance (e.g. torque). However, due
pulp and paper, mining, petrochemical and other industries.It nitoring. They are also equipped with a calibration resistor that
to variations in supply voltage and frequency, the motor may
meets Petrobras standard N1735, section 4. changes linearly with temperature, monitoring the temperature
not fully achieve all its performance characteristics and may
result in a temperature rise exceeding the rated value. rise of the motor by monitoring the display, with high accura-
The spraying solution description and other options are des- cy and sensitive response. The same temperature measuring
The motor must be suitable for its main function (e.g. torque) in
cribed as follows: element can be set to alarm (operating above normal opera-
zone B. However, the variation of performance characteristics
in zone B will be greater than that in Zone A. The temperature ting temperature) and trip (usually set to the highest tempera-
212P Paint scheme - standard ture corresponding to the motor insulation level).
rise will also be higher than the rated condition and the tem-
Primer: one coat, 75 to 105 m epoxy
perature rise in zone A. Long-term use of motor in Zone B is
Middle: one layer, 100 to 140 m epoxy Other temperature measuring equipment is as follows.
not recommended.
Figure 22 - Installation as defined by IEC60034-7 Finish: one coat, 70 to 100 m polyurethane paint
Low-voltage motor Derating to limit temperature rise at sinusoidal source level ** HGF motor total length when fitted with forced ventilation unit (mm) 4.14.4 Capacitor
Peak voltage dV/dT * Time between INTERVAL LIMITED BY APPLY THIS EQUATION Frame
Motor rated voltage Rise time F 0.10 ≤ f/fn < 0.25 TR = (f/fn) + 0.50 Poles Not Suitable to encoder Suitable to encoder HGF high voltage motor can be equipped with one capacitor
(phase-phase) (phase-phase) pulses IEC NEMA
VNOM ≤ 1000 V ≤ 1600 V ≤ 5200 V/μs G 0.25 ≤ f/fn < 0.50 TR = 0.40(f/fn) + 0.65 2 2025 2135 per phase. Capacitors are placed in the main junction box and
460 V < VNOM ≤ 575 V ≤ 1800 V ≤ 6500 V/μs ≥ 0,1 μs ≥ 6 μs H 0.50 ≤ f/fn < 0.83 TR = 0.30f/fn) + 0.70 315C/D/E 5009/10/11T
4-8 2055 2165 are recommended for use when the system is likely to gener-
575 V < VNOM ≤ 690 V ≤ 2200 V ≤ 7800 V/μs I 0.83 ≤ f/fn ≤ 1.0 TR = 0.95 2 2205 2315
ate voltage spikes during operation or atmospheric discharge.
J f/fn > 1.0 TR = 0.95 / (f/fn) 355C/D/E 5810/11/12T The capacitor is mounted on a stainless steel hood and has
4-8 2275 2385
* NEMA MG1 Part 30 Definitions
the following characteristics:
2 2190 2300
400L/A/B 6806/07/08T
(*) When the top curve (green line) is applied, the temperature 4-8 2260 2370
High-voltage motor rise of the motor is limited by the temperature grade of the in- 2 2490 2600 HGF high voltage motor can be equipped with one capacitor
400C/D/E 6809/10/11T
The limit values of HGF motors are shown below, including the sulating material. For example, the temperature rise of a motor 4-8 2560 2670 per phase. Capacitors are placed in the main junction box and
2 2780 2880 are recommended for use when the system is likely to generate
performance of direct drive and variable frequency drive (en- with insulation grade F should be limited to 105K. This curve is 450 70
4-8 2800 2900
hanced insulation) : only applicable to motors with Grade F insulation and Grade B voltage spikes during operation or atmospheric discharge. The
500 80 4-8 3120 3220
Wire insulation Main insulation temperature rise. 560 88 4-8 3500 3600
capacitor is mounted on a stainless steel hood and has the
(phase-phase) (phase-ground) 630 96 4-8 3700 3800 following characteristics:
Motor rated Insulation Peak Peak (**) When the lower curve (blue line) is adopted, the tempe- · Capacitance - 0.5 F
dV/dT dV/dT 4.14 Special auxiliary parts
voltage level (1) voltage voltage rature rise of the motor driven by frequency conversion is the · Rated voltage - maximum 7.2kV
VNOM ≤ 1000 V Normal ≤ 3100 V ≤ 11300 V/μs ≤ 1800 V ≤ 11300 V/μs · Voltage class - 15 kV
1000 V < VNOM Normal ≤ 6500 V ≤ 4000 V/μs ≤ 3800 V ≤ 4000 V/μs same as that of the motor driven by sinusoidal power. That is, HGF motors can be installed with a variety of accessories to
≤ 4160 V Reinforced ≤ 7800 V ≤ 4000 V/μs ≤ 4500 V ≤ 4000 V/μs even if the motor of insulation grade F temperature rise grade B better meet specific application requirements.
4160 V < VNOM Normal ≤ 10300 V ≤ 4000 V/μs ≤ 5900 V ≤ 4000 V/μs is driven by the frequency converter, it still keeps the tempera- The following accessories are commonly used accessories for
≤ 6900 V Reinforced ≤ 12400 V ≤ 4000 V/μs ≤ 7200 V ≤ 4000 V/μs ture rise of grade B (DT=80 K).
6900 V < VNOM Normal ≤ 15600 V ≤ 3000 V/μs ≤ 9000 V ≤ 3000 V/μs HGF motors and can be provided upon customer‘s request.
≤ 10000 V Reinforced ≤ 17100 V ≤ 3000 V/μs ≤ 9900 V ≤ 3000 V/μs
Note: The derating curve shown in FIG. 24 is related to the 4.14.1 Anti-reversing ratchet
* NEMA MG1 Part 30 Definitions temperature and heat grade of the motor winding. The curve
** Frequency converter motor to strengthen insulation cannot predict the thermal tolerance coefficient of the motor, Some applications do not allow the motor to rotate in both
but only indicates the torque limit of the variable-frequency directions. In this case, an anti-reverse ratchet can be installed
Notes for low-voltage and high-voltage motors: drive motor. so that the shaft can only rotate in one direction.
1. Switching frequency shall be limited to 5kHz. Switching fre- Figure 29-HGF motor typical capacitor
quency exceeding 5kHz will accelerate winding aging and may 4.13.3. Axial current limit 4.14.2 Encoder
damage bearing. 4.14.5 Alternative solution
2. If one of the above conditions is not met (including switching As mentioned above, in motor frequency conversion applica-
An encoder can be used when precise speed control is requi-
frequency), a filter shall be installed at the output end of the tions, the non-shaft extension bearings must be insulated and The replacement of the old motor lacks flexibility. To solve this
red. The encoder is installed in the fan housing and directly
frequency conversion accordingly. the shaft extension bearings must be equipped with grounding problem, the HGF motor can be configured with a base or ex-
connected with the motor shaft. As standard configuration,
3. The following requirements are derived from the standards carbon brushes to prevent shaft current from flowing through tended foot to solve the problem of complete motor replace-
the bearings. WEG USES the Dynapar HS35 encoder. ment.
IEC60034-17 and IEC60034-25.
4.13.2 Torque limit for variable frequency applications Mechanical speed limit
No matter the frequency conversion drive or direct drive, the
When the motor frequency conversion is applied, especially speed of HGF motor cannot exceed 120% of the synchronous
when the low speed is applied, the cooling air flow of the mo- speed.
tor is low, and the temperature rise of the motor will be higher
than that of the directly connected application. High tempera- 4.13.4. Controlled cooling
ture rise can be avoided by using forced air cooling equipment.
Even at low motor speed, forced air cooling device can ensure When independent cooling is needed, the HGF motor can be
that the motor cooling air flow constant. installed with a forced air cooling device, as shown in the figure
TEFC motor can also be used as VFD drive when the motor below. The forced air cooling device comprises a motor driven Figure 27 -- Dynapar HS35 encoder
driven load meets the following requirements: directly by a grid power source. The forced cooling device al- Figure 30 - Motor base
ways provides a constant flow of cooling air to the cooling fins 4.14.3 Surge protective devices
of the main motor regardless of the change of speed of the If the required motor frame size (shaft center height) is one level
main motor under any application. One surge protector can be installed in each phase of HGF higher than the standard motor (for example, the 315 frame
The following is the diagram of HGF motor forced air cooling motor junction box. This kind of equipment is manufactured size motor requires 355 shaft center height), then extended
device according to iec60099-4 standard and divided into 3kV, 6 kV, 9 feet can be used at this time to change the frame foot height .
kV and 12 kV according to voltage By using this method, the motor can achieve the required size
(including foot installation and shaft center height).
22 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 23
www.weg.net www.weg.net
5. Structure configuration
4.15 Exploded view Frame 315C/D/E 355C/D/E 400L/A/B 400/C/D/E 450 500 560 630
Mechanical features
The main components of HGF motor are introduced in the following decomposition diagram. Please refer to the detailed dimen-
sion drawing for the terminal box (main terminal box and auxiliary terminal box) information. Nameplate identification
Installation B3R(E)
Grounding method Double ground (+ 2 in the terminal box installed in the frame)
2P Aluminum Consulting
Fan Material
4P-12P Polymer Consulting
2P Use cast iron or steel fan cover/when the motor USES friction-proof -
bearings and no forced air cooling/When the motor USES a sliding
Fan housing Material Steel plate
4P-12P bearing, or an anti-friction bearing and is forced to be air-cooled, use a steel plate
steel plate fan hood
End cover Material FC-200 Cast iron
Project 212P
Painting
Colour RAL 5009
Electrical characteristics
Material Copper
Winding Dipping paint Low voltage - continuous drop dip/high voltage - vacuum pressure dip VPI
Insulation grade F (DT 80K)
Service factor 1.0
24 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 25
www.weg.net 6. Optional Configuration (IEC) 6. Optional Configuration (IEC) www.weg.net
Characteristic 315C/D/E 355C/D/E 400L/A/B 400/C/D/E 450 500 560 630 Characteristic 315C/D/E 355C/D/E 400L/A/B 400/C/D/E 450 500 560 630
Service factor Key
Service factor 1.00 P P P P P P P P B Key P P P P P P P P
Service factor 1.15 O O O O O O O O C Key O O O O O O O O
Service factor 1.25 E E E E E E E E Shaft lock device P P P P P P P P
Insulation grade Drive end bearing type
F DT 70K E E E E E E E E Ball bearing (2-pole) P P P P P NA NA NA
F DT 80K P P P P P P P P Ball bearings (4 to 8 poles)* P P P P P P NA NA
F DT 105K O O O O O O O O Roller bearings (4 to 8 poles) O O O O O O P P
H DT 80K E E E E E E E E Sliding bearing (HGF) 2) O O O O O O E E
H DT 105K E E E E E E E E Non-drive bearing type
H DT 125K E E E E E E E E Ball bearing P P P P P P NA NA
Heater band BE Angle contact ball(2pole) O E NA NA NA NA NA NA
110-127 / 220-240 V P P P P P P P P BE Angle contact ball(4 to 8pole) O O O O O O NA NA
380-480 V O O O O O O O O Insulated sliding bearing(HGF)2) O O O O O O E E
Heat protection device - Alarm (winding) Bearing cap
Bimetallic thermal protectors - 130°C alarm O O O O O O O O Bearing cap P P P P P P P P
3 wire PT100 - Alarm P P P P P P P P Terminal box cover
3 wire PT100 - Alarm - calibration O O O O O O O O Plastic thread sealing cover P P P P P P P P
PTC thermistor - 130°C - Alarm O O O O O O O O Casting thread sealing cover O O O O O O O O
Thermal protection - Tripping (winding) No cap O O O O O O O O
Bimetal thermal protectors - 155°C - tripping O O O O O O O O Cooling method
Line 3 PT100 - Tripping P P P P P P P P TEFC ( fan cooling) P P P P P P P P
Line 3 PT100 - Tripping - Calibration O O O O O O O O TFVE Silencer with steel plate O O O O O O O O
PTC thermistor - 155°C - tripping O O O O O O O O TFVE With a fiber muffler O O O O O O O O
Design TEBC (Fan cooling) O O O O O O O O
N (low voltage only) P P P P P P P P TFVF Silencer with steel plate E E E E E E E E
Type of junction box TFVF With fiber silencer E E E E E E E E
HGF (FC-200 cast iron) P P P P P P P P Inside painting
HGF (steel plate) high voltage O O O O O O O O Internal anticorrosive painting O O O O O O O O
HGF (steel plate) low voltage O O O O O O O O Drain contamination
Cable gland Open drain cover (automatic) P P P P P P P P
plastic O O O O O O O O Closed drain cover O O O O O O O O
copper O O O O O O O O The bolt material
Stainless steel O O O O O O O O Stainless steel bolt O O O O O O O O
Flange Oil extraction
Flange FF O O O O O O O O Through the plastic drain valve P P P P P P E E
Without flange P P P P P P P P Drain oil through end cap E E E E E E E E
Rain cover - cast iron fan cover - 2 and 4 pole 1 O O O O NA NA NA NA Strong cold suite
Rain cover - cast iron fan cover - 6 poles and above 1 O O O O NA NA NA NA Strong cooling suite with encoder reserved O O O O O O O O
Terminal blocks Strong cooling suite is not reserved with encoder O O O O O O O O
Terminals - Low and high voltage P P P P P P P P Strongly cooled motor voltage
Protection grade 208-230/460V O O O O O O O O
IP55 P P P P P P P P 220-240/380-415//460V O O O O O O O O
IP56 O O O O O O O O 220/380-440V O O O O O O O O
IP65 O O O O O O O O 380-415/660-690//460V O O O O O O O O
IP66 O O O O O O O O 525-550V O O O O O O O O
IPW55 O O O O O O O O 575V O O O O O O O O
IPW56 O O O O O O O O 220/380 O O O O O O O O
IPW65 O O O O O O O O 220/440 O O O O O O O O
IPW66 O O O O O O O O 230/460V O O O O O O O O
Drive end bearing seal 240/480V O O O O O O O O
Labyrinth seal P P P P P P P P 380/660V O O O O O O O O
Labyrinth seal+Viton seal O O O O O O O O 400/690V O O O O O O O O
Mechanical seal 2 O O O O O O O O 440V O O O O O O O O
Non drive bearing seal 460V O O O O O O O O
Same as the driver P P P P P P P P 480V O O O O O O O O
Spray paint plan Encoder
212E O O O O O O O O Without encoder P P P P P P P P
212P P P P P P P P P HS 35 encoder O O O O O O O O
213E O O O O O O O O Leine&Linde XH861 900220-2048 E E E E E E E E
214P O O O O O O O O Drive end grounding carbon brush
212P with PFI 1023 O O O O O O O O Drive end grounding carbon brush O O O O O O O O
213E with PFI 1023 O O O O O O O O Fan housing material - sliding bearing and rolling bearing with strong cooling kit
Grounding Welded steel plate (2-pole horizontal installation) P P P P P NA NA NA
Double ground (1 in the junction box + 2 in the frame) P P P P P P P P Welded steel plate (horizontal installation with 4 poles
Double ground + auxiliary junction box (1 in the junction O O O O O P P P
O O O O O O O O or above)
box + 3 in the frame) Fan housing material - rolling bearings without strong cooling kit
Fan Casting P P P P NA NA NA NA
Aluminum (2 and 4 poles) P P P P P P P E Silencer - no strong cooling for motor
Aluminium (6 poles and above) P P P P P P P P No silencer P P P P P P P P
Cast iron (4 poles and above) O O O O O O O O With silencer O O O O O O O O
Steel plate NA NA NA NA NA NA P P Bearing thermal protection
Threaded center hole (shaft) P P P P P P P P Bimetal thermal protectors - drive end/non-drive end O O O O O O O O
Lubrication 3 wire PT100 - drive/non-drive P P P P P P P P
Mobil Polyrex EM P P P P P P P P 3-wire calibrated PT100 - drive end/non-drive end O O O O O O O O
Oil filling device 2 x 3 wire PT100 - Driver end/non-driver end O O O O O O O O
Carbon steel oil filling plant P P P P P P P P 2 X 3 line calibrated PT100 - drive end/non-drive end O O O O O O O O
Drive end insulation Direction of rotation
Uninsulated conductor P P P P P P P P Bidirectional (4-8 poles) P P P P P P P P
Insulated bearing E E E E E E E E Clockwise (2 poles) P P P P P E E E
Insulation cover E E E E E E E E Counterclockwise (2 poles) O O O O O O O O
Non-drive end insulation Steering plate P P P P P P P P
Uninsulated conductor O O NA NA NA NA NA NA Dipping paint
Insulated bearing E E E E E E E E Low voltage - continuous drip immersion P P P P P P P P
Insulation cover P P P P P P P P high voltage - VPI P P P P P P P P
Drive end bearing type high voltage - 2xVPI O O O O O O O O
C3 P P P P P P NA NA Vibration level
C4 E E E E E E E E A grade P P P P P P P P
Non-drive bearing type B grade O O O O O O O O
C3 P P P P P P P P Vibrating sensor
C4 E E E E E E E E SPM Vibration sensor reservation O O O O O O O O
BE angular contact bearing (2-pole) 1 O O NA NA NA NA NA NA
BE angular contact bearing (4 to 8 poles) 1 O O O O O O NA NA
Dynamic balance type
Half bond equilibrium P P P P P P P P
Reduced half bond equilibrium O O O O O O O O
Shaft material Note: P(standard), O(optional), NA(not applicable), E(consulting WEG).
42CrMo P P P P P P P P * Optional as a 400 stand vertical motor only - roller bearings are not suitable at this time;
AISI 4140 O O O O O O O O 1) Standard characteristics of vertical motor;
AISI 4140 H NA NA NA NA P P NA NA 2) Standard characteristics of sliding bearing motor.
Q345 (4 to 8 poles) NA NA NA NA NA O P P
AISI 1524 (4 to 8 poles) NA NA NA NA NA O O O
26 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 27
www.weg.net www.weg.net
7. Electrical data (IEC) - 380V 50Hz 7. Electrical data (IEC) - 3300V 50Hz
Allowable locked 380V Allowable locked 3300V
Output Full Locked Locked Break- Output Full Locked Locked Break-
rotor time (s) Efficiency Power Factor Full rotor time (s) Efficiency Power Factor Full
load rotor rotor down Inertia J Weight Sound Rated load rotor rotor down Inertia J Weight Sound Rated
Frame load Frame load
torque current torque Ti/ torque (kg.m²) (kg) dB(A) speed torque current torque torque (kg.m²) (kg) dB(A) speed
kW HP Hot Cold 50% 75% 100% 50% 75% 100% current kW HP Hot Cold 50% 75% 100% 50% 75% 100% current
(Nm) II/In Tn Tb/Tn (rpm) (Nm) II/In Ti/Tn Tb/Tn (rpm)
In (A) In (A)
2P 2P
200 270 315C/D/E 65.4 6.9 1.0 2.4 3.21 24 53 1749 75 2980 94.9 95.7 95.8 0.81 0.87 0.89 357 250 340 315C/D/E 801 6.8 1.4 2.5 3.3 17 19 1831 75 2981 93.4 94.3 94.4 0.81 0.87 0.89 52.1
250 340 315C/D/E 81.8 6.9 1.1 2.4 4.01 20 44 1959 75 2978 95.3 95.7 95.8 0.86 0.89 0.89 445 280 380 315C/D/E 897 6.7 1.4 2.5 3.5 17 18 1873 75 2981 93.8 94.6 94.6 0.82 0.88 0.89 58.2
280 380 315C/D/E 91.6 6.9 1.1 2.4 4.01 16 35 1959 75 2977 95.4 95.7 95.8 0.85 0.90 0.90 494 315 430 315C/D/E 1011 5.2 1.1 2.0 2.9 22 24 1986 75 2976 94.3 95.0 94.9 0.84 0.88 0.89 65.3
315 430 315C/D/E 103 7.5 1.4 2.5 4.50 14 31 2009 75 2979 95.4 95.9 96.0 0.85 0.90 0.90 554 355* 480 315C/D/E 1138 5.8 1.2 2.2 3.1 19 20 2051 75 2978 94.5 95.2 95.2 0.81 0.87 0.88 73.8
355 480 355C/D/E 116 6.8 1 2.4 5.74 45 99 2768 82 2976 95.5 96.0 96.1 0.85 0.90 0.90 623 355 480 355C/D/E 1139 5.0 1.0 1.9 3.9 21 22 2569 82 2975 94.0 94.8 94.9 0.85 0.88 0.89 73.6
400 550 355C/D/E 131 7.0 1.4 2.4 6.44 45 99 2828 82 2980 95.7 96.0 96.2 0.81 0.87 0.89 709 400 550 355C/D/E 1285 4.8 1.0 1.8 4.2 21 22 2631 82 2974 94.4 95.0 95.0 0.85 0.88 0.89 82.8
450 610 355C/D/E 147 7.0 1.6 2.4 7.12 33 73 3078 82 2982 95.7 96.2 96.3 0.81 0.87 0.89 798 450 610 355C/D/E 1444 5.4 1.1 2.0 4.5 18 19 2729 82 2977 94.5 95.2 95.3 0.85 0.88 0.89 92.9
500 680 355C/D/E 163 7.0 1.1 2.4 7.93 35 77 2998 82 2980 95.7 96.2 96.3 0.85 0.90 0.90 877 500 680 355C/D/E 1604 5.4 1.1 2.1 4.9 16 17 2822 82 2977 94.7 95.4 95.4 0.80 0.86 0.88 104.3
560 750 400L/A/B 183 7.5 1.3 2.5 11.0 26 57 3717 88 2980 95.5 96.2 96.3 0.84 0.89 0.90 982 560 750 355C/D/E 1794 7.8 1.2 2.8 6.7 20 25 2904 82 2981 94.8 95.5 95.5 0.85 0.88 0.89 115.2
630 850 400L/A/B 206 7.5 1.3 2.5 12.9 26 57 3817 88 2980 95.7 96.3 96.4 0.85 0.90 0.90 1110 560 750 400L/A/B 1794 8.0 1.2 3.1 7.2 15 24 3635 88 2981 95.6 96.1 96.1 0.85 0.88 0.89 114.6
4P 630 850 400L/A/B 2020 7.1 1.0 2.7 7.3 15 24 3660 88 2978 95.9 96.2 96.1 0.85 0.88 0.89 128.8
250 340 315C/D/E 164 7.5 2.0 2.5 5.75 17 37 1850 75 1485 95.2 95.8 96.0 0.76 0.83 0.86 460 710 970 400L/A/B 2272 7.5 1.4 2.7 10.5 12 13 3779 88 2984 95.7 96.3 96.3 0.83 0.88 0.89 145.0
280 380 315C/D/E 184 7.5 2 2.6 6.32 19 42 1900 75 1485 95.4 95.9 96.0 0.76 0.83 0.86 516 710 970 400C/D/E 2275 7.5 1.2 2.9 13.5 19 30 4605 88 2980 96.0 96.3 96.2 0.85 0.88 0.89 145.0
315 430 315C/D/E 207 7.5 2 2.7 7.01 16 35 2000 75 1485 95.3 95.9 96.0 0.75 0.82 0.85 586 800 1100 400C/D/E 2556 7.5 1.1 2.7 16.9 29 31 4588 88 2989 96.1 96.6 96.6 0.85 0.88 0.89 162.9
355 480 315C/D/E 233 7.5 2 3 7.58 15 33 2050 75 1485 95.3 95.7 96.0 0.75 0.82 0.86 654 900* 1250 400C/D/E 2878 7.0 1.1 2.5 17.8 26 28 4707 88 2987 94.7 95.6 95.8 0.85 0.88 0.89 184.7
400 550 315C/D/E* 263 7.5 2 2.7 8.50 15 33 2100 75 1484 95.7 96.1 96.1 0.75 0.83 0.86 736 900 1250 450 2877 7.3 1.1 2.7 21.0 24 25 5815 88 2987 94.5 95.5 95.8 0.85 0.88 0.89 184.7
450 610 355C/D/E 294 6.7 1.5 2.3 13.8 30 66 2900 75 1489 95.6 96.0 96.2 0.79 0.85 0.87 817 1000 1350 450 3198 7.1 1.1 2.6 21.1 21 22 5866 88 2986 94.9 95.8 96.0 0.85 0.88 0.89 204.8
500 680 355C/D/E 327 6.7 1.5 2.4 15.3 26 57 3000 75 1488 95.8 96.1 96.3 0.77 0.85 0.87 906 1100 1500 450 3516 7.7 1.3 2.9 21.1 17 18 5850 88 2987 95.0 95.9 96.1 0.85 0.88 0.89 225.0
560 750 400L/A/B 367 7.0 1.4 2.2 17.6 20 44 3700 78 1488 95.9 96.2 96.4 0.76 0.82 0.86 1030 1250 1700 450 3999 6.6 1.1 2.5 22.2 19 20 6007 88 2985 96.5 96.9 96.8 0.85 0.88 0.89 253.8
630 850 400C/D/E 412 7.0 1.4 2.3 20.0 18 40 4500 78 1489 96.0 96.3 96.5 0.76 0.82 0.86 1160 4P
710 970 400C/D/E 465 7.7 1.4 2.4 22.4 13 29 4650 78 1487 96.1 96.6 96.6 0.74 0.82 0.86 1290 250 340 315C/D/E 1613 5.7 1.0 2.2 3.8 33 34 1844 75 1480 94.7 94.9 94.5 0.79 0.85 0.87 53.0
800 1100 450 522 7.0 0.7 2.5 22.0 20 44 5123 85 1492 95.6 96.4 96.6 0.76 0.84 0.86 1460 280 380 315C/D/E 1806 5.9 1.0 2.3 4.1 30 32 1911 75 1481 94.9 95.1 94.7 0.79 0.85 0.87 59.2
900 1250 450 588 7.0 0.7 2.5 25.0 20 44 5420 85 1492 95.6 96.3 96.6 0.76 0.84 0.86 1640 315 430 315C/D/E 2030 6.2 1.1 2.5 4.1 25 26 1925 75 1482 95.0 95.2 94.8 0.76 0.84 0.87 67.0
1000 1350 450 653 7.0 0.7 2.5 28.0 20 44 5720 85 1492 95.7 96.5 96.7 0.76 0.84 0.86 1830 355 480 315C/D/E 2280 6.8 1.3 2.7 6.0 20 21 2059 75 1487 94.9 95.3 95.1 0.76 0.84 0.87 75.0
6P 400 550 355C/D/E 2573 5.1 0.9 2.0 7.4 29 31 2673 75 1485 94.5 95.1 95.0 0.78 0.84 0.86 85.4
160 220 315C/D/E 158 6.1 1.9 2.2 7.46 20 44 1720 68 988 95.0 95.6 95.6 0.70 0.80 0.82 311 450 610 355C/D/E 2892 4.9 0.9 2.0 7.8 33 35 2746 75 1486 94.9 95.4 95.2 0.76 0.83 0.85 97.1
185 250 315C/D/E 182 6.1 1.9 2.2 8.76 16 35 1820 68 988 95.1 95.5 95.7 0.70 0.80 0.82 358 500 680 355C/D/E 3212 5.0 0.9 2.0 8.8 33 35 2915 75 1486 95.0 95.5 95.4 0.76 0.83 0.85 107.6
200 270 315C/D/E 197 6.3 2.2 2.3 9.51 17 37 1860 68 988 95.3 95.5 95.8 0.70 0.80 0.83 382 560 750 355C/D/E 3598 5.1 0.9 2.0 8.8 28 30 2944 75 1486 95.2 95.6 95.5 0.74 0.82 0.85 121.0
250 340 315C/D/E 247 6.5 2.3 2.4 11.4 14 31 1960 68 985 95.0 95.5 95.8 0.68 0.78 0.82 483 630* 850 355C/D/E 4044 6.6 1.2 2.7 10.7 17 18 2924 75 1488 95.2 95.7 95.6 0.78 0.86 0.88 130.8
280 380 355L/A/B 276 6.5 1.9 2.5 13.1 28 62 2310 70 989 95.0 95.6 95.8 0.70 0.79 0.83 535 630 850 400L/A/B 4041 5.9 1.0 2.4 13.7 21 22 3666 78 1489 95.6 96.1 96.0 0.74 0.83 0.86 133.6
315 430 355L/A/B 310 6.3 1.3 2.5 14.3 26 57 2400 70 989 95.2 95.9 95.8 0.73 0.82 0.85 587 710 970 400L/A/B 4559 5.9 1.1 2.5 14.7 18 19 3794 78 1487 95.7 96.2 96.0 0.73 0.82 0.85 151.5
355 480 355C/D/E 350 6.3 1.3 2.5 16.0 27 59 2820 70 988 95.5 95.8 95.8 0.75 0.83 0.86 655 800 1100 400L/A/B 5129 6.2 1.1 2.7 15.1 16 17 3844 78 1490 95.9 96.3 96.2 0.70 0.80 0.84 173.3
400 550 355C/D/E* 394 6.2 1.5 2.5 17.6 24 53 2980 70 988 95.6 96.0 96.0 0.75 0.83 0.86 736 900 1250 400C/D/E 5769 6.4 1.1 2.7 17.5 16 17 4505 78 1490 96.1 96.5 96.4 0.71 0.81 0.85 192.7
450 610 400L/A/B 442 6.2 1.3 2.3 22.0 20 44 3600 70 992 95.6 96.0 96.0 0.73 0.81 0.85 838 1000 1350 400C/D/E 6410 6.4 1.1 2.7 19.8 16 17 4816 78 1490 96.2 96.6 96.5 0.72 0.81 0.85 213.1
500 680 400L/A/B 491 6.5 1.3 2.3 24.8 16 35 3800 70 992 95.7 96.1 96.1 0.73 0.82 0.85 931 1100* 1500 400C/D/E 7047 6.9 1.2 2.5 24.0 13 14 4837 78 1491 96.4 96.7 96.6 0.78 0.85 0.88 227.6
560 750 400C/D/E 550 6.0 1.4 2.3 27.9 16 35 4440 70 992 95.8 96.2 96.2 0.71 0.81 0.85 1040 1100 1500 450 7037 7.4 1.0 3.0 30.8 21 22 6025 85 1493 96.6 97.1 97.2 0.76 0.84 0.87 228.0
630 850 450 618 6.5 0.8 2.4 33.0 20 44 5100 82 993 96.1 96.2 96.2 0.77 0.84 0.85 1170 1250 1700 450 7997 7.2 1.0 2.9 32.0 19 20 6128 85 1493 96.5 97.1 97.2 0.74 0.83 0.86 261.7
710 970 450 696 6.5 0.8 2.4 37.4 20 44 5420 82 993 96.1 96.2 96.2 0.77 0.84 0.85 1320 1400 1900 450 8966 7.3 1.3 2.9 32.6 10 10 6220 85 1491 96.4 97.0 97.1 0.72 0.81 0.85 295.6
800 1100 450 784 6.5 0.8 2.4 41.9 20 44 5720 82 994 96.2 96.3 96.3 0.77 0.84 0.85 1480 1400 1900 500 8959 6.3 0.9 2.4 44.5 22 23 7552 90 1492 96.3 96.8 96.7 0.81 0.87 0.89 283.8
900 1250 450* 882 6.7 0.8 2.4 44.2 20 44 5870 82 994 96.1 96.3 96.3 0.77 0.84 0.85 1670 1600 2200 500 10237 6.3 0.9 2.5 47.6 20 21 7831 90 1493 96.4 96.9 96.9 0.81 0.87 0.89 324.0
High-Output Design 1800 2500 560 11496 7.0 0.8 2.6 102.3 32 34 11108 92 1495 96.7 97.1 97.2 0.82 0.87 0.89 365.7
315 430 355C/D/E 310 6.3 1.3 2.5 14.3 26 57 2690 70 989 95.2 95.9 95.8 0.73 0.82 0.85 587 6P
8P 250 340 315C/D/E 2419 5.6 1.1 2.3 5.6 35 37 1943 68 987 93.8 94.3 94.1 0.64 0.75 0.79 58.6
160 220 315C/D/E 211 5.7 1.2 2.3 10.1 22 48 1850 68 738 93.9 94.5 94.5 0.68 0.78 0.82 314 280 380 315C/D/E 2710 5.6 1.1 2.3 6.4 36 38 2065 68 987 94.0 94.5 94.2 0.65 0.75 0.80 65.0
185 250 315C/D/E 244 5.7 1.2 2.4 11.9 25 55 2000 68 738 94.1 94.6 94.6 0.70 0.79 0.82 362 315* 430 315C/D/E 3037 5.7 1.1 2.2 9.0 33 39 2165 68 991 93.7 94.4 94.3 0.68 0.78 0.82 71.2
200 270 315C/D/E 264 6.2 1.2 2.5 12.9 19 42 2100 68 739 94.3 94.8 94.8 0.68 0.78 0.82 391 315 430 355C/D/E 3035 5.8 0.9 2.8 9.3 36 43 2630 70 991 94.4 95.0 94.9 0.60 0.72 0.78 74.7
250 340 355L/A/B 328 5.5 1.2 2.4 17.6 21 46 2450 70 742 94.6 95.3 95.3 0.67 0.76 0.82 486 355 480 355C/D/E 3421 5.7 0.9 2.7 10.1 35 43 2710 70 991 94.5 95.1 95.0 0.64 0.75 0.81 81.1
280 380 355C/D/E 368 5.5 1.2 2.3 20.1 22 48 2820 70 742 95.0 95.5 95.4 0.70 0.78 0.82 544 400 550 355C/D/E 3855 5.8 0.9 2.7 10.8 34 39 2818 70 991 95.0 95.4 95.2 0.65 0.76 0.81 90.6
315 430 355C/D/E 413 5.8 1.2 2.4 22.3 19 42 2980 70 742 95.1 95.5 95.5 0.68 0.77 0.82 612 450 610 355C/D/E 4332 6.5 1.1 3.2 12.2 23 33 2958 70 992 94.7 95.3 95.3 0.59 0.71 0.78 105.9
355 480 400L/A/B 465 6.8 1.8 2.5 32.2 22 48 3600 70 743 94.6 95.2 95.5 0.66 0.77 0.81 697 500* 680 355C/D/E 4806 6.9 1.4 2.8 16.6 23 24 3112 70 994 94.5 95.3 95.3 0.62 0.74 0.79 115.7
400 550 400L/A/B 524 6.8 1.8 2.5 32.8 22 48 3600 70 743 94.6 95.3 95.6 0.66 0.77 0.81 785 500 680 400L/A/B 4813 6.6 1.0 2.6 17.7 30 31 3565 70 992 95.2 95.7 95.7 0.66 0.77 0.81 112.4
450 610 400L/A/B 590 6.8 1.2 2.5 37.3 20 44 3800 70 743 94.8 95.5 95.8 0.66 0.77 0.81 881 560 750 400L/A/B 5389 6.9 1.2 2.8 18.7 25 26 3669 70 992 95.1 95.7 95.7 0.63 0.75 0.80 127.7
500 680 400C/D/E 655 6.8 1.2 2.5 44.3 22 48 4640 70 743 95.0 95.7 96.0 0.66 0.77 0.81 977 630 850 400L/A/B 6063 6.8 1.1 2.7 21.1 26 27 3902 70 992 95.4 95.9 95.9 0.65 0.76 0.81 142.0
560 750 450 732 6.0 0.8 2.2 60.2 26 57 5875 75 745 95.6 96.0 96.1 0.71 0.80 0.84 1050 710* 970 400L/A/B 6821 6.9 1.2 2.7 26.5 22 23 3910 70 994 94.7 95.6 95.7 0.67 0.78 0.82 157.9
630 850 450 825 6.2 0.8 2.2 64.6 26 57 6080 75 744 95.8 96.2 96.3 0.74 0.82 0.84 1180 710 970 400C/D/E 6851 5.1 1.2 1.9 26.5 19 20 4837 70 990 95.2 95.7 95.6 0.69 0.78 0.81 159.7
10P 800 1100 400C/D/E 7680 6.6 1.1 2.4 33.8 33 34 5092 70 995 95.1 95.9 96.0 0.69 0.79 0.83 176.3
75 100 315L/A/B 124 5.5 1.5 2.0 6.90 15 33 1580 78 590 91.6 92.5 92.5 0.51 0.63 0.70 176 900 1250 450 8645 6.1 0.9 2.4 44.5 29 31 5923 82 994 95.8 96.5 96.7 0.72 0.81 0.84 192.8
90 125 315L/A/B 149 5.5 1.5 2 8.39 15 33 1700 78 590 91.8 92.8 92.8 0.51 0.63 0.70 211 1000 1350 450 9596 6.9 1.1 2.8 46.8 23 25 6068 82 995 95.5 96.4 96.7 0.65 0.76 0.81 222.8
110 150 315C/D/E 182 5.5 1.5 2 10.1 15 33 1900 78 590 92.2 93.0 93.0 0.51 0.63 0.70 257 1000 1350 450 9596 6.9 1.1 2.8 46.8 23 25 6068 82 995 95.5 96.4 96.7 0.65 0.76 0.81 222.8
132 175 315C/D/E 218 5.8 1.6 2 12.9 15 33 2100 78 590 92.6 93.2 93.2 0.51 0.63 0.70 307 1250* 1700 450 12012 6.6 1.1 2.6 50.4 19 20 6099 82 994 95.9 96.6 96.7 0.74 0.82 0.86 263.6
160 220 355L/A/B 264 5.5 1.2 2 17.0 20 44 2350 80 591 92.8 93.8 94.0 0.50 0.62 0.69 375 1100 1500 500 10564 6.3 0.9 2.4 82.9 26 28 7086 80 994 96.1 96.5 96.4 0.76 0.84 0.87 230.1
185 250 355C/D/E 305 5.5 1.2 2 20.1 20 44 2750 80 591 93.0 94.0 94.2 0.50 0.62 0.69 433 1250 1700 500 12005 6.4 0.9 2.5 88.3 24 25 7344 80 994 96.2 96.6 96.5 0.76 0.84 0.87 261.2
200 270 355C/D/E 330 5.5 1.2 2 21.7 20 44 2820 80 591 93.2 94.2 94.4 0.50 0.62 0.69 466 1400 1900 560 13422 6.3 0.7 2.5 129.4 49 55 10041 88 996 96.4 96.8 96.8 0.81 0.87 0.89 284.0
220 300 355C/D/E 363 5.5 1.2 2 24.8 20 44 2980 80 591 93.4 94.4 94.6 0.50 0.62 0.69 512 1600 2200 560 15339 6.5 0.7 2.6 144.2 47 49 10778 88 996 96.9 97.2 97.2 0.76 0.84 0.87 329.5
250 340 400L/A/B 411 5.5 1 2.2 26.5 22 48 3400 80 593 94.8 95.4 95.4 0.60 0.72 0.78 509 8P
280 380 400L/A/B 460 5.5 1 2.2 31.1 22 48 3545 80 593 95.0 95.6 95.6 0.60 0.72 0.78 571 250 340 355C/D/E 3216 5.7 1.6 2.4 13.1 33 40 2700 70 742 93.6 94.2 94.0 0.60 0.72 0.77 60.1
315 430 400L/A/B 517 5.5 1 2.2 33.5 22 48 3725 80 593 95.2 95.8 95.8 0.60 0.72 0.78 640 280 380 355C/D/E 3603 5.6 1.6 2.3 14.0 33 38 2784 70 742 93.8 94.4 94.2 0.61 0.72 0.77 67.1
355 480 400L/A/B 583 5.5 1 2.2 38.1 22 48 3930 80 593 95.4 96.0 96.0 0.60 0.72 0.78 720 315 430 355C/D/E 4052 5.7 1.7 2.4 14.5 28 34 2823 70 742 93.8 94.4 94.2 0.59 0.71 0.76 76.5
400 550 400L/A/B 657 5.5 1 2.2 40.4 22 48 4100 80 593 95.6 96.2 96.2 0.60 0.72 0.78 809 355* 480 355C/D/E 4560 6.2 1.5 2.6 20.4 30 32 3027 70 743 93.3 94.2 94.3 0.57 0.69 0.76 86.8
450 610 450 737 6.2 0.8 2.2 67.0 25 55 4770 80 595 95.4 95.8 95.8 0.60 0.72 0.79 903 355 480 400L/A/B 4569 4.9 1.2 2.1 25.8 32 33 3374 70 742 94.5 95.0 94.7 0.66 0.76 0.80 81.6
500 680 450 818 6.2 0.8 2.2 75.0 25 55 5020 80 595 95.6 96.0 96.0 0.60 0.72 0.79 1000 400 550 400L/A/B 5153 4.6 1.1 1.9 29.7 36 37 3571 70 741 94.7 95.0 94.7 0.69 0.78 0.81 90.7
560 750 450 917 6.2 0.8 2.2 80.0 25 55 5305 80 595 95.8 96.2 96.2 0.61 0.73 0.80 1110 450 610 400L/A/B 5798 4.4 1.0 1.9 26.0 35 37 3729 70 741 94.4 95.0 94.8 0.65 0.75 0.79 105.1
High-Output Design 500* 680 400L/A/B 6422 5.3 1.0 2.1 33.8 39 41 3891 70 744 94.4 95.1 95.0 0.69 0.78 0.82 112.5
160 220 315C/D/E* 264 5.8 1.6 2.0 13.8 15 33 2150 78 590 92.4 93.0 93.0 0.51 0.63 0.70 374 500 680 400C/D/E 6429 5.2 1.3 2.3 30.8 29 31 4498 70 743 94.2 94.9 94.9 0.59 0.71 0.77 120.2
250 340 355C/D/E* 412 5.5 1.2 2 26.4 20 44 3050 80 591 93.4 94.4 94.6 0.50 0.62 0.69 582 560 750 400C/D/E 7216 4.5 1.1 1.9 33.1 35 36 4647 70 741 94.8 95.2 94.9 0.66 0.76 0.80 129.5
12P 630 850 400C/D/E 8109 5.0 1.3 2.2 35.4 27 28 4818 70 742 94.5 95.1 95.1 0.60 0.72 0.77 150.5
132 175 355L/A/B 261 4.3 1.3 1.8 18.5 20 44 2460 80 493 93.3 94.0 94.0 0.48 0.60 0.67 319 710* 970 400C/D/E 9095 6.0 1.1 2.3 45.6 37 49 5027 70 746 94.7 95.4 95.4 0.65 0.75 0.80 162.7
160 220 355C/D/E 316 4.3 1.2 1.8 24.6 20 44 3100 80 493 93.5 94.0 94.0 0.48 0.60 0.67 386 710 970 450 9108 6.1 1.0 2.5 56.3 38 42 6162 75 744 95.6 96.0 95.8 0.73 0.81 0.85 152.9
200 270 400L/A/B 393 5.5 1 2.1 33.0 20 44 3400 80 496 94.0 94.5 94.5 0.54 0.67 0.74 435 750 1000 450 9620 6.0 0.9 2.5 59.2 35 43 6294 75 745 95.6 96.0 95.8 0.71 0.80 0.84 163.0
250 340 400L/A/B 492 5.5 1.2 2.3 38.6 20 44 3690 80 495 94.8 95.0 95.0 0.57 0.69 0.75 533 800 1100 450 10260 6.1 0.9 2.5 63.4 31 43 6481 75 745 95.6 96.0 95.8 0.72 0.81 0.84 173.4
280 380 400C/D/E 551 5.5 1.2 2.3 41.0 20 44 4230 80 495 94.8 95.0 95.0 0.57 0.69 0.75 597 900 1250 500 11522 5.5 0.7 2.2 95.1 44 66 6694 78 746 95.7 96.2 96.1 0.72 0.80 0.83 197.3
315 430 450 620 5.5 0.8 1.9 59.1 40 88 4555 80 495 94.9 95.1 95.1 0.61 0.71 0.77 654 1000 1350 500 12807 5.3 0.7 2.1 107.3 43 66 7086 78 746 95.9 96.3 96.2 0.74 0.82 0.84 215.9
355 480 450 699 5.5 0.8 1.9 67.6 40 88 4790 80 495 95.1 95.3 95.3 0.61 0.71 0.77 735 1100 1500 560 14071 6.0 0.7 2.4 252.7 57 66 10433 80 747 95.7 96.3 96.3 0.74 0.82 0.85 235.0
400 550 450 787 5.5 0.8 1.9 72.0 40 88 5050 80 495 95.3 95.5 95.5 0.61 0.71 0.77 826 1250 1700 560 15988 6.1 0.7 2.4 268.3 53 59 10764 80 747 95.8 96.4 96.4 0.74 0.82 0.85 266.6
450 610 450 885 5.5 0.8 1.9 76.2 40 88 5310 80 495 95.5 95.7 95.7 0.62 0.72 0.78 916
500 680 450 984 5.5 0.8 1.9 80.5 40 88 5620 80 495 95.7 95.9 95.9 0.62 0.72 0.78 1020
High-Output Design
160 220 355L/A/B* 316 4.3 1.3 2.0 21.1 20 44 2520 80 493 93.3 94.0 94.0 0.48 0.60 0.67 386
28 HGF - Three Phase Induction Motor *Indicates temperature rise class F *Indicates temperature rise class F HGF - Three Phase Induction Motor 29
www.weg.net www.weg.net
7. Electrical data (IEC) - 6000V 50Hz 7. Electrical data (IEC) - 10000V 50Hz
Allowable locked 6000V Allowable locked 10000V
Output Full Locked Locked Break- Output Full Locked Locked Break-
rotor time (s) Efficiency Power Factor Full rotor time (s) Efficiency Power Factor Full
load rotor rotor down Inertia J Weight Sound Rated load rotor rotor down Inertia J Weight Sound Rated
Frame load Frame load
torque current torque Ti/ torque (kg.m²) (kg) dB(A) speed torque current torque torque (kg.m²) (kg) dB(A) speed
kW HP Hot Cold 50% 75% 100% 50% 75% 100% current kW HP Hot Cold 50% 75% 100% 50% 75% 100% current
(Nm) II/In Tn Tb/Tn (rpm) (Nm) II/In Ti/Tn Tb/Tn (rpm)
In (A) In (A)
2P 2P
220 300 315C/D/E 705 6.5 1.3 2.3 3.2 16 22 1777 75 2981 92.9 94.2 94.5 0.82 0.87 0.89 25.2 280 380 355C/D/E 897 6.5 1.4 2.5 3.9 21 22 2554 82 2981 92.7 93.9 94.2 0.82 0.88 0.89 19.3
250 340 315C/D/E 801 7.0 1.4 2.5 3.3 14 19 1802 75 2982 93.2 94.4 94.8 0.78 0.85 0.88 28.8 315 430 355C/D/E 1010 5.6 1.2 2.1 4.2 23 25 2634 82 2979 93.3 94.2 94.3 0.84 0.88 0.89 21.7
280 380 315C/D/E 898 5.9 1.3 2.3 2.9 22 23 1942 75 2979 93.6 94.5 94.5 0.82 0.87 0.89 32.0 355* 480 355C/D/E 1139 7.4 1.3 2.7 5.1 16 23 2597 82 2977 93.4 94.3 94.3 0.85 0.88 0.89 24.4
315* 430 315C/D/E 1010 5.6 1.1 2.1 2.9 20 21 1939 75 2978 94.0 94.7 94.7 0.81 0.87 0.88 36.2 355 480 400L/A/B 1137 6.8 1.1 2.7 6.4 24 39 3397 88 2980 94.0 94.8 94.8 0.79 0.86 0.89 24.3
315 430 355C/D/E 1139 5.2 1.0 2.0 3.9 23 24 2519 82 2976 93.5 94.4 94.5 0.82 0.87 0.88 40.9 400 550 400L/A/B 1281 7.1 1.2 2.9 6.6 23 36 3457 88 2981 94.3 95.0 95.1 0.73 0.82 0.86 28.2
355 480 355C/D/E 1284 5.0 1.0 1.9 4.2 23 24 2605 82 2975 93.9 94.7 94.7 0.84 0.88 0.89 45.8 450 610 400L/A/B 1439 7.4 1.3 2.8 9.4 18 19 3536 88 2986 94.2 95.1 95.2 0.76 0.84 0.87 31.2
400 550 355C/D/E 1445 4.9 1.0 1.8 4.5 22 23 2699 82 2975 94.3 95.0 94.9 0.85 0.88 0.89 51.3 500 680 400L/A/B 1599 7.6 1.3 2.9 9.4 15 16 3533 88 2986 94.3 95.2 95.3 0.74 0.83 0.86 35.1
450 610 355C/D/E 1604 5.3 1.0 2.0 4.9 19 20 2783 82 2977 94.0 94.9 94.9 0.85 0.88 0.89 57.0 500 680 400C/D/E 1604 7.5 1.2 2.9 10.9 13 20 4178 88 2977 94.9 95.4 95.4 0.85 0.88 0.89 34.0
500* 680 355C/D/E 1794 7.3 1.1 2.7 6.3 23 29 3110 82 2980 94.9 95.5 95.5 0.85 0.88 0.89 63.4 560 750 400C/D/E 1793 7.8 1.4 2.9 11.5 20 23 4175 88 2982 94.9 95.6 95.6 0.84 0.88 0.89 38.0
500 680 400L/A/B 1603 6.3 0.8 2.4 6.8 23 37 3536 88 2978 95.1 95.7 95.6 0.85 0.88 0.89 56.6 560 750 450 1791 7.1 1.2 2.7 17.5 35 36 5324 88 2986 95.6 96.1 96.1 0.85 0.88 0.89 37.8
560 750 400L/A/B 1794 7.0 1.1 2.7 6.7 18 28 3521 88 2981 95.4 96.0 96.0 0.85 0.88 0.89 63.1 630 850 450 2013 7.1 1.1 2.7 18.8 34 36 5459 88 2988 93.3 94.6 95.0 0.85 0.88 0.89 43.0
630 850 400L/A/B 2016 7.1 1.1 2.6 10.2 15 16 3704 88 2984 95.4 96.0 96.1 0.77 0.85 0.87 72.3 710 970 450 2270 7.1 1.1 2.7 19.5 32 33 5606 88 2987 93.6 94.9 95.2 0.85 0.88 0.89 48.4
630 850 400C/D/E 2019 7.4 1.1 2.8 12.1 20 32 4331 88 2980 95.7 96.1 96.0 0.85 0.88 0.89 71.0 750 1000 450 2398 7.6 1.3 2.8 19.6 26 27 5608 88 2987 93.8 95.0 95.3 0.85 0.88 0.89 51.1
710 970 400C/D/E 2276 7.1 1.3 2.7 12.1 19 20 4318 88 2979 95.8 96.2 96.1 0.85 0.88 0.89 79.9 800 1100 450 2557 7.5 1.2 2.8 19.5 26 27 5621 88 2988 94.0 95.1 95.5 0.85 0.88 0.89 54.4
750 1000 400C/D/E 2398 6.6 1.0 2.3 17.0 36 37 4567 88 2987 96.2 96.6 96.5 0.85 0.88 0.89 84.1 4P
800* 1100 400C/D/E 2558 7.0 1.2 2.5 17.0 28 29 4566 88 2986 96.3 96.6 96.5 0.85 0.88 0.89 89.6 280 380 355C/D/E 1797 5.4 0.9 2.1 7.2 38 50 2659 75 1488 93.3 94.2 94.2 0.75 0.83 0.85 20.1
800 1100 450 2558 7.4 1.2 2.8 19.6 24 25 5628 88 2986 94.3 95.3 95.6 0.85 0.88 0.89 90.5 315 430 355C/D/E 2022 5.4 0.9 2.1 7.8 36 47 2741 75 1488 93.6 94.4 94.4 0.75 0.83 0.85 22.6
900 1250 450 2876 7.5 1.1 2.8 20.9 24 25 5737 88 2988 94.4 95.5 95.7 0.85 0.88 0.89 101.6 355* 480 355C/D/E 2273 7.1 1.1 2.8 9.5 19 31 2725 75 1491 94.1 94.8 94.8 0.74 0.83 0.86 25.0
1000 1350 450 3198 6.8 1.1 2.6 21.1 22 23 5806 88 2986 94.7 95.7 95.9 0.85 0.88 0.89 112.8 355 480 400L/A/B 2278 5.7 0.9 2.3 13.4 34 42 3624 78 1488 94.2 94.9 94.8 0.78 0.84 0.87 24.9
1100 1500 450 3515 7.7 1.2 2.9 20.9 19 20 5806 88 2989 94.9 95.9 96.1 0.83 0.88 0.89 123.7 400 550 400L/A/B 2566 6.0 1.0 2.4 14.4 27 37 3750 78 1488 94.6 95.1 95.0 0.77 0.84 0.87 27.9
4P 450 610 400L/A/B 2886 6.3 1.1 2.6 13.6 24 29 3633 78 1489 94.5 95.1 95.1 0.74 0.83 0.86 31.8
220 300 315C/D/E 1416 6.5 1.1 2.6 3.5 23 31 1764 75 1484 94.1 94.5 94.3 0.73 0.82 0.86 26.2 500 680 400L/A/B 3206 6.4 1.1 2.7 13.6 21 26 3632 78 1489 94.7 95.3 95.2 0.73 0.82 0.85 35.5
250 340 315C/D/E 1609 6.6 1.2 2.6 4.1 18 28 1872 75 1484 94.2 94.6 94.3 0.77 0.84 0.87 29.2 530 720 400L/A/B 3389 7.5 1.2 2.9 17.3 16 23 3688 78 1493 94.6 95.4 95.4 0.68 0.78 0.83 38.5
280 380 315C/D/E 1803 6.4 1.1 2.5 4.4 19 30 1940 75 1483 94.6 94.9 94.5 0.77 0.84 0.87 32.8 560 750 400C/D/E 3588 6.5 1.1 2.7 17.3 23 28 4464 78 1490 95.1 95.6 95.6 0.71 0.80 0.85 40.0
315 430 315C/D/E 2029 6.6 1.2 2.6 4.5 18 27 2011 75 1483 94.8 95.0 94.7 0.75 0.83 0.87 36.8 630 850 400C/D/E 4037 6.6 1.1 2.7 18.2 19 25 4569 78 1490 95.2 95.7 95.7 0.70 0.80 0.84 45.1
335* 455 315C/D/E 2147 7.1 1.2 2.8 6.2 15 24 2045 75 1490 94.6 95.1 95.0 0.72 0.82 0.86 39.7 710 970 450 4547 7.7 1.4 3.0 27.6 15 16 5542 85 1491 95.3 95.9 95.9 0.76 0.84 0.87 49.2
355 480 355C/D/E 2283 5.1 0.9 2.1 6.9 31 33 2570 75 1485 94.8 95.2 95.0 0.77 0.84 0.87 41.5 800 1100 450 5115 7.6 1.0 3.1 29.3 21 29 5794 85 1494 95.6 96.2 96.2 0.72 0.81 0.85 56.2
400 550 355C/D/E 2571 5.5 0.9 2.3 7.4 27 29 2664 75 1486 94.8 95.3 95.2 0.75 0.83 0.86 47.1 900 1250 450 5761 8.0 1.4 3.1 32.6 14 15 6139 85 1492 95.7 96.4 96.6 0.76 0.84 0.88 61.4
450 610 355C/D/E 2892 5.5 1.0 2.3 8.5 27 28 2831 75 1486 94.4 95.1 95.1 0.75 0.83 0.86 52.8 1000 1350 500 6398 5.9 0.7 2.3 42.6 41 43 7175 90 1493 95.4 96.1 96.1 0.83 0.88 0.89 67.4
500 680 355C/D/E 3218 4.9 0.9 2.0 8.0 28 30 2794 75 1484 94.9 95.4 95.2 0.75 0.83 0.85 59.4 1100 1500 500 7036 6.4 0.8 2.5 44.9 34 36 7379 90 1493 95.6 96.2 96.3 0.82 0.88 0.89 73.8
560* 750 355C/D/E 3593 6.1 1.1 2.4 10.5 23 24 2858 75 1488 94.8 95.4 95.3 0.76 0.84 0.87 65.4 1250 1700 500 7996 6.2 0.8 2.4 47.8 34 36 7647 90 1493 95.8 96.4 96.4 0.82 0.87 0.89 84.0
560 750 400L/A/B 3593 5.7 0.9 2.3 13.7 25 26 3639 78 1488 95.4 95.9 95.8 0.76 0.84 0.87 65.0 1400 1900 560 8944 6.9 0.8 2.6 90.1 34 36 10429 92 1495 95.9 96.6 96.7 0.83 0.88 0.90 92.6
630 850 400L/A/B 4043 6.1 1.1 2.6 13.7 19 20 3632 78 1488 95.4 95.9 95.8 0.71 0.81 0.85 74.7 1500 2000 560 9586 6.6 0.7 2.6 81.9 33 35 10788 92 1494 96.0 96.8 97.0 0.80 0.86 0.89 100.9
710 970 400L/A/B 4553 5.9 1.0 2.4 14.7 20 20 3750 78 1489 95.7 96.2 96.0 0.74 0.83 0.86 82.8 6P
750 1000 400L/A/B 4799 6.9 1.0 2.6 18.3 21 22 3791 78 1492 95.8 96.3 96.2 0.74 0.83 0.86 87.4 280 380 400L/A/B 2695 6.7 1.0 2.7 19.4 22 36 3633 70 992 93.7 94.5 94.4 0.69 0.79 0.83 20.5
800 1100 400C/D/E 5138 5.9 1.1 2.5 18.2 20 21 4503 78 1487 96.0 96.3 96.1 0.72 0.81 0.85 94.5 315 430 400L/A/B 3033 6.3 0.9 2.6 19.4 25 40 3624 70 992 93.7 94.5 94.4 0.69 0.79 0.83 23.1
900 1250 400C/D/E 5772 6.3 1.1 2.7 19.1 18 19 4665 78 1489 96.0 96.4 96.3 0.65 0.76 0.82 110.2 355 480 400L/A/B 3419 6.3 0.9 2.7 19.3 32 42 3639 70 992 93.9 94.7 94.7 0.66 0.77 0.82 26.5
1000 1350 450 6397 7.6 1.1 3.0 29.4 21 22 5811 85 1493 96.4 97.0 97.1 0.76 0.84 0.87 113.3 400 550 400L/A/B 3849 6.4 1.0 2.4 19.9 26 41 3691 70 992 94.2 94.9 94.9 0.68 0.78 0.82 29.7
1100 1500 450 7036 7.8 1.2 3.1 30.9 19 20 5968 85 1493 96.5 97.0 97.1 0.74 0.83 0.86 126.1 450* 610 400L/A/B 4320 6.3 1.0 2.4 26.1 22 35 3821 70 995 93.5 94.5 94.7 0.62 0.73 0.79 34.8
1250 1700 450 7997 7.5 1.1 3.1 30.9 17 18 5965 85 1493 96.3 96.9 97.0 0.73 0.82 0.85 145.5 450 610 400C/D/E 4340 5.1 1.2 1.9 25.7 31 32 4631 70 990 94.0 94.7 94.6 0.69 0.78 0.81 33.8
1250 1700 500 7993 6.4 0.8 2.6 42.3 26 27 7149 90 1493 95.9 96.5 96.6 0.79 0.86 0.88 141.1 500 680 400C/D/E 4814 6.0 1.4 2.3 26.5 24 25 4707 70 992 93.9 94.8 94.8 0.65 0.76 0.80 38.0
1400 1900 500 8951 6.5 0.8 2.6 52.6 25 26 7779 90 1494 96.0 96.6 96.7 0.79 0.86 0.88 157.5 560* 750 400C/D/E 5373 6.7 1.0 2.4 31.7 26 42 4823 70 995 94.2 95.1 95.2 0.67 0.77 0.82 41.6
1600 2200 560 10217 7.1 0.8 2.7 96.2 34 36 10718 92 1496 96.3 96.9 97.0 0.80 0.86 0.88 179.6 560 750 450 5385 6.5 1.1 2.7 40.6 23 30 5601 82 993 94.4 95.1 95.1 0.71 0.81 0.85 39.9
6P 630 850 450 6046 6.8 1.0 2.7 44.5 25 40 5794 82 995 94.9 95.8 96.1 0.70 0.80 0.84 44.9
220 300 315C/D/E 2126 6.2 1.2 2.6 6.0 24 38 1960 68 988 93.2 93.9 93.7 0.63 0.74 0.80 28.4 710 970 450 6814 6.5 1.0 2.6 48.7 24 39 5913 82 995 95.1 95.9 96.1 0.71 0.80 0.85 50.4
250 340 315C/D/E 2418 5.7 1.1 2.3 6.4 28 42 2028 68 987 93.5 94.1 93.8 0.65 0.75 0.80 32.1 800 1100 500 7683 6.0 0.8 2.4 83.3 30 40 7160 80 994 95.4 95.9 95.9 0.76 0.83 0.86 55.8
280* 380 315C/D/E 2695 6.3 1.3 2.5 9.0 21 33 2131 68 992 92.9 93.8 93.9 0.63 0.75 0.80 35.9 900 1250 500 8639 6.5 0.9 2.6 87.7 25 33 7347 80 995 95.4 96.0 96.0 0.74 0.82 0.86 63.1
280 380 355C/D/E 2695 6.5 1.0 3.1 10.8 25 40 2768 70 992 94.1 94.8 94.8 0.62 0.74 0.80 35.6 1000 1350 500 9600 6.4 0.9 2.5 88.8 28 34 7437 80 995 95.6 96.1 96.1 0.75 0.83 0.86 69.6
315 430 355C/D/E 3033 6.1 0.9 2.8 11.5 24 38 2844 70 992 94.7 95.5 95.5 0.65 0.76 0.81 39.0 1100 1500 560 10545 6.4 0.7 2.6 124.7 51 66 9875 88 996 95.1 95.9 96.1 0.77 0.84 0.87 76.0
355 480 355C/D/E 3420 5.7 0.9 2.7 11.4 33 49 2857 70 991 94.9 95.6 95.7 0.62 0.74 0.79 45.0 1250 1700 560 11981 6.1 0.6 2.5 128.2 48 65 10000 88 996 95.4 96.2 96.3 0.76 0.84 0.87 86.6
400 550 355C/D/E 3853 5.8 0.9 2.8 12.1 31 44 2942 70 991 95.0 95.7 95.8 0.61 0.73 0.79 51.2 8P
450* 610 355C/D/E 4327 6.3 1.2 2.5 16.2 28 31 3048 70 993 94.7 95.6 95.7 0.65 0.76 0.81 55.9 250 340 400L/A/B 3207 5.1 1.4 2.2 28.1 34 55 3522 70 744 92.6 93.5 93.5 0.62 0.73 0.78 19.7
450 610 400L/A/B 4334 6.2 1.0 2.4 17.5 35 37 3514 70 992 95.0 95.5 95.4 0.69 0.79 0.83 54.8 280 380 400L/A/B 3585 5.5 0.8 2.1 38.4 24 39 3722 70 746 92.9 93.8 93.7 0.66 0.76 0.81 21.3
500 680 400L/A/B 4815 6.3 1.0 2.4 18.7 32 34 3626 70 992 95.2 95.7 95.6 0.68 0.78 0.82 61.1 280 380 400C/D/E 3602 4.9 1.1 2.1 31.4 51 54 4157 70 742 92.7 93.6 93.6 0.65 0.75 0.80 21.7
560 750 400L/A/B 5391 6.6 1.1 2.6 19.9 29 30 3743 70 992 95.1 95.7 95.6 0.66 0.77 0.82 69.1 315 430 400C/D/E 4050 5.2 1.2 2.2 33.4 44 46 4257 70 743 92.6 93.7 93.7 0.62 0.73 0.79 24.7
630* 850 400L/A/B 6055 6.6 1.2 2.5 26.5 26 27 3892 70 994 94.8 95.5 95.6 0.71 0.80 0.84 75.7 355 480 400C/D/E 4571 4.6 1.1 1.9 37.2 49 51 4456 70 742 93.0 93.8 93.7 0.66 0.76 0.80 27.4
630 850 400C/D/E 6071 5.7 1.4 2.2 24.7 17 18 4581 70 991 94.5 95.2 95.3 0.64 0.75 0.80 79.9 400 550 400C/D/E 5122 6.4 1.1 2.4 47.5 22 35 4662 70 746 93.2 94.2 94.3 0.65 0.76 0.81 30.3
710 970 400C/D/E 6815 6.6 1.1 2.5 33.6 37 39 5020 70 995 94.1 95.1 95.4 0.69 0.79 0.83 86.3 400 550 450 5116 6.0 0.9 2.6 55.7 21 33 5869 75 747 92.8 94.0 94.2 0.59 0.71 0.78 31.6
800 1100 450 7680 6.6 1.0 2.6 44.5 30 32 5803 82 995 95.5 96.3 96.5 0.71 0.80 0.84 94.6 450 610 450 5757 5.8 1.0 2.7 53.2 17 28 5854 75 746 92.1 93.5 93.8 0.47 0.60 0.69 40.3
900 1250 450 8638 6.8 1.1 2.7 46.8 27 28 5944 82 995 95.5 96.3 96.5 0.69 0.79 0.84 107.2 500 680 450 6395 6.3 1.0 2.6 56.1 19 31 6007 75 747 93.2 94.3 94.5 0.60 0.72 0.78 39.2
1000 1350 450 9596 6.9 1.0 2.8 50.0 26 27 6019 82 995 95.3 96.2 96.5 0.67 0.77 0.82 121.1 560 750 500 7157 6.6 0.8 2.8 84.9 23 36 6323 78 747 94.1 95.0 95.2 0.61 0.73 0.79 43.2
1100* 1500 450 10561 7.2 1.2 2.9 50.5 20 21 6025 82 995 95.6 96.4 96.6 0.70 0.80 0.84 129.7 630 850 500 8052 6.7 0.9 2.8 89.9 20 32 6475 78 747 94.2 95.1 95.3 0.61 0.73 0.79 48.6
1000 1350 500 9605 6.0 0.9 2.3 84.1 30 32 7180 80 994 96.0 96.4 96.3 0.78 0.85 0.87 114.7 710 970 500 9075 6.7 0.9 2.8 99.9 20 32 6795 78 747 94.4 95.3 95.4 0.63 0.74 0.80 54.0
1100 1500 500 10560 6.4 0.9 2.5 89.9 28 29 7445 80 995 96.3 96.8 96.9 0.76 0.84 0.87 126.2 800 1100 500 10226 6.5 0.8 2.7 113.8 23 38 7262 78 747 94.8 95.5 95.6 0.65 0.75 0.81 59.9
1250 1700 560 11979 6.5 0.6 2.7 120.7 50 59 9781 88 996 95.9 96.5 96.6 0.77 0.85 0.88 141.9 900 1250 560 11513 5.3 0.6 2.1 238.7 55 88 10016 80 746 94.8 95.8 96.1 0.73 0.81 0.84 64.4
1400 1900 560 13416 6.5 0.7 2.6 137.6 51 59 10434 88 997 96.1 96.7 96.7 0.78 0.86 0.88 157.9 1000 1350 560 12785 6.3 0.8 2.5 238.7 34 55 10017 80 747 94.7 95.8 96.1 0.70 0.79 0.83 72.2
8P 1100 1500 560 14059 6.8 0.9 2.7 254.3 29 46 10316 80 747 94.6 95.7 96.1 0.68 0.78 0.82 80.3
220 300 355C/D/E 2831 5.6 1.5 2.3 12.3 30 44 2613 70 742 93.4 94.0 93.8 0.61 0.72 0.78 29.0
250 340 355C/D/E 3212 6.3 1.9 2.7 13.1 26 34 2699 70 743 93.0 93.9 94.0 0.54 0.67 0.74 34.7
280 380 355C/D/E 3596 6.3 1.8 2.8 13.8 31 32 2767 70 744 93.4 94.6 94.9 0.52 0.65 0.72 39.3
315* 430 355C/D/E 4039 6.1 1.3 2.6 18.8 27 40 2910 70 745 93.1 94.1 94.2 0.54 0.66 0.73 43.8
315 430 400L/A/B 4052 5.0 1.2 2.1 29.6 40 45 3540 70 742 94.2 94.7 94.4 0.67 0.77 0.81 39.8
355 480 400L/A/B 4574 4.3 1.0 1.8 24.4 44 47 3562 70 741 94.1 94.6 94.4 0.67 0.76 0.79 45.6
400 550 400L/A/B 5153 4.4 1.0 1.9 26.0 40 42 3667 70 741 94.1 94.7 94.5 0.66 0.75 0.79 51.4
450* 610 400L/A/B 5770 5.6 1.1 2.2 33.0 43 45 3816 70 745 93.9 94.8 94.8 0.66 0.76 0.80 56.9
450 610 400C/D/E 5798 4.4 1.1 1.9 29.2 39 41 4388 70 741 94.6 95.0 94.7 0.67 0.76 0.80 57.3
500 680 400C/D/E 6451 4.1 0.9 1.7 33.1 44 46 4647 70 740 94.9 95.2 94.8 0.70 0.78 0.81 62.8
560 750 400C/D/E 7197 5.5 1.4 2.5 33.1 25 27 4625 70 743 94.4 95.1 95.1 0.56 0.68 0.74 76.1
630* 850 400C/D/E 8063 6.6 1.2 2.7 42.9 24 38 4828 70 746 94.5 95.3 95.4 0.59 0.71 0.77 82.3
630 850 450 8077 5.9 0.9 2.4 66.7 34 54 6518 75 745 95.8 96.3 96.3 0.71 0.80 0.84 75.3
710 970 450 9100 6.2 0.9 2.5 66.7 32 51 6544 75 745 95.8 96.4 96.4 0.70 0.79 0.83 85.4
800 1100 500 10237 5.9 0.8 2.3 100.2 40 65 6846 78 746 95.5 96.0 96.0 0.72 0.81 0.84 94.9
900 1250 500 11517 6.0 0.8 2.4 107.4 36 57 7067 78 746 95.6 96.1 96.0 0.73 0.82 0.85 106.0
1000 1350 560 12790 6.0 0.7 2.4 223.3 43 63 9753 80 747 95.3 96.0 96.0 0.73 0.81 0.85 118.4
1100 1500 560 14071 6.0 0.7 2.3 252.7 46 65 10381 80 747 95.5 96.1 96.2 0.74 0.82 0.85 129.3
30 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 31
www.weg.net www.weg.net
8. Mechanical data (IEC) ( Unit : mm) 8. Mechanical data (IEC) (Unit : mm)
Flange, fan hood with muffler and steel junction box dimensions - Horizontal and general thrust vertical mounting motors
Frame size HGF 315C/D/E to 400C/D/E
Motor dimensions - anti-friction bearing and general thrust vertical motor
Frame size HGF 315C/D/E to 400C/D/E
Steel plate fan cover
L’ with silencer L’ without silencer
IEC Frame AC HC
Poles Poles
2 4 ≥6 2 4 ≥6
315C/D/E 1945 2005 1910 1835
355C/D/E 2180 2290 2150 2060
400L/A/B 890 845 2165 2370 2360 - 2070 2110
400C/D/E 2465 2670 2660 - 2370 2410
3xM20x1.5
355C/D/E 355 50 740 950 28 48 315C/D/E - - 925 985 970 1020 990 1300 1225 1365
2145 M24 6322 6319 6322 6322
355C/D/E - - 955 1050 1005 1085 1025 1375 1255 1430
2105 M20 6315 6315 6315 6315
400L/A/B 400L/A/B
2175 M24 6324 6319 6324 6324 - - 995 1135 1045 1170 1065 1450 1295 1515
400 840 1035 36 56 130 400C/D/E
2405 M20 6315 6315 6315 6315
400C/D/E
2475 M24 6324 6319 6324 6324
32 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 33
www.weg.net www.weg.net
8. Mechanical data (IEC) (Unit : mm) 8. Mechanical data (IEC) (Unit : mm)
Motor dimensions - Sliding bearing
Frame size HGF 315C/D/E to 400C/D/E
2435 2490** M20 FNLB 9-80 IP55 FNLQ 9-80 IP55 FNLB 9-80 IP55 FNLB 9-80 IP55
2xRP(RWG)3"
Bearings
Dimensions of fan cover with noise suppressor IEC H HA. HC HD K K´ L d1 s1 s2 HGF HGF API 541
Frame
HGF HGF API 541 DE NDE DE NDE
Frame
Poles Poles 2655 M20* 6220 6220 6220 6220
450 450 60 950 1155 36 56
2xM63x1.5
2xM20x1.5
2 >=4 2 >=4 2485 M24 6328 6324 6328 6328
315C/D/E 2230 2315 2380 2365 500 500 65 1050 1215 42 62 2670 M24 6330 6324 6330 6330
355C/D/E 2465 2610 2490 2635 560 560 70 1174 1321 42 62 2850 M24
On request
400L/A/B 2450 2725 2475 2775 630 630 80 1360 1490 42 72 3200 M30
400C/D/E 2750 3025 2775 3075
Note: * is the data of 2-pole motor; ** Is HGF API 541 Note: * is the data of 2-pole motor.
Frame 560 with grease lubrication; Frame 630 4Poles with oil lubrication;
Frame 630 6P and above with grease lubrication.
34 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 35
www.weg.net www.weg.net
8. Mechanical data (IEC) (Unit : mm) 8. Mechanical data (IEC) (Unit : mm)
Flange, fan hood with muffler and steel junction box dimensions - Horizontal and general thrust vertical mounting motors Motor dimensions - Sliding bearing
Frame size HGF 450 to 630 Frame size HGF 450 to 630
Flange
IEC Frame
Flange C ØM ØN ØP ØS T N° of Holes
450 FF - 1080 315 1080 1000 1150 28 IEC A AA AB AC AD AE B BA BC BB BD C D E ES N F G GD
Frame
500 FF - 1180 375 1180 1120 1100 28
6 8 800
560 - - - - - - 85* 170* 140* 22* 76* 14*
900
630 - - - - - -
450 750 250 950 1000 815 540 1000 230 660 1450 90 475
1120 130 250 200 32 119 18
1250
900
1000
500 850 275 1050 1100 825 550 1120 300 450 1660 150 500 120 210 200 32 119 18
1250
1400
5
1000
1120
560 950 320 1200 1220 890 620 1250 400 500 1900 180 560 130 250 200 32 119 18
Cast iron terminal box 1400
(NEMA I, voltage up to 1kV) 1600
Steel plate terminal box Steel plate terminal box 1000
(NEMA II, voltage up to 6.9kV) (Can be placed capacitor and 1120
lightning arrester)
630 1250 330 1440 1400 940 670 1250 450 600 2000 180 600 150 250 200 36 138 20
1400
1600
Bearings
IEC H HA. HC HD K K´ L d1 s1 s2 HGF HGF API 541
Frame
Steel plate termina box
(NEMA I, voltage up to 1kV) DE NDE DE NDE
2885 M20* FNLB 9-80 IP55 FNLQ 9-80 IP55 FNLB 9-80 IP55 FNLB 9-80 IP55
450 450 60 950 1155 36 56
Steel plate terminal box 2805 M24 FNLB 11-125 IP55 FNLQ 11-125 IP55 FNLB 11-125 IP55 FNLB 11-125 IP55
IEC Frame
2xM63x1.5
2xM20x1.5
AD'A HD'A AD'B HD'B AD'C HD'C AD'D HD'D AD'E HD'E
450 950 1200 1035 1255 1085 1295 1105 1575 1335 1635 500 500 65 1050 1215 42 62 2920 M24 FNLB 11-125 IP55 FNLQ 11-125 IP55 FNLB 11-125 IP55 FNLB 11-125 IP55
500 - - - - - - - - - -
560 560 70 1174 1321 42 62 3130 M24
560 - - - - - - - - - - Consult WEG
630 - - - - - - - - - - 630 630 80 1360 1490 42 72 3400 M30
36 HGF - Three Phase Induction Motor HGF - Three Phase Induction Motor 37
www.weg.net www.weg.net
From our wide Services portfolio, stands out the list of interventions on products from WEG activ-
ity areas: Electric Motors, Energy and Automation, being the most common: Products Procedure
Automation Motor Internal External
Inspection, Tests and Technical Analyses General Repair and overhaul X X X X
From all the inspections, tests and technical analyses we Product repair that may include the replacement of the compo-
X X X X
nents by original parts
have capacity to offer, we emphasize the following:
Commissioning and start up X X X
Production and expedition of spare parts to all Repair of electrical machines (Ex and Safety) X X X
over the world; Inspection and/or replacement of sleeve bearing or bearings X X X
Repair of the sleeve bearings shell X X X
Application diagnosis on site or in our factory;
High, Medium and Low Voltage rewinding X X
Technical advise on best, reliable and efficient
Stator or rotor core replacement X X
solutions on energy saving. Brushes and brushes holder replacement X X X
Shaft complete replacement or repair of shafts with grinding
X X
finishing of complete rotor
Dynamic balancing of rotor (Maximum speed 1600 rpm 20T) X X
Field dynamic balancing X X
Centring service X X
Painting (standard and special plan) X X X
Inspection, tests and technical analysis X X X X
Energy Efficiency Study X X X
Training of product maintenance X X X
Automation
Analysis of application improvements and technical assessment to the client, helping on the choice of the most appropri-
ate equipment, targeting the application/optimizing installation efficiency
Manufacturing, Installation, Modification, Start-Up and Maintenance of Electrical Panels
Explosive
Support on the settings parametrization of Variable Speed Drives and Soft Starters Atmospheres
Commissioning and Start-Up of applications with Variable Speed Drives
WEG Products Training
www.weg.net